V14
2
Specifications
CFM05S Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 85~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….………….................... 40A max. @240Vac
Conducted EMI ……………………………………..…… CISPR/FCC Class B
Leakage Current …………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8mS typ. @115Vac
Short Circuit Protection ………………………… Continuous (Auto Recovery)
Over Voltage Protection ……………................... TVS Component to Clamp
Temperature Coefficient ……………………............................… ±0.05%/℃
SAFETY AND EMC:
GENERAL SPECIFICATIONS:
Emission and Immunity ……………....… EN55022 Class B, EN61000-6-3
Isolation ……………………………………..……. Input to output = 4,242VDC
EN61000-3-2, EN61000-3-3, EN55024
Operating Temperature ............................ 0 ~ ℃85℃ (see derating curve)
EN61204-3, EN61000-6-1
Storage Temperature ……………………………...….......……........ -20~85℃
Safety ………………………………... IEC60950-1, EN60950-1, UL60950-1
Humidity ...................................................... 93% RH max. Non condensing
NOTE:
Cooling …………………………………..……………….. Natural Convection
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Switching Frequency ………………………….................. 60KHz Typical
Ripple & Noise measuring @20MHz BW.
MTBF …..…… MIL-HDBK-217F, GB, at 25 /115VAC℃ …… 200Khrs min.
2. Voltage accuracy is set at 100% rated load and 25℃ Ta.
Altitude ……………………..………………...………………………….. 2000m
3. Line regulation is measured from 100Vac to 240Vac with full load.
Dimensions …….…….. 2.165x1.378x0.827inches (55.00x35.00x21.00mm)
4. Load regulation is measured from 10% to 100% full load.
Weight ……………………………………………………... 35g (0.08 Pounds)
5. Typical efficiency at 230VAC and full load at 25℃.
CFM05 Series
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Millimeters:X.XX±0.5
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
25%
50%
75%
100%
0 10 20 30 40 50 60 70 80 90
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)