8845A/8846A Digital Multimeters accessory guide Technical Data Introduction The 8845A/8846A Digital Multimeters are complemented by a comprehensive range of accessories, all of which are designed to help you get the most from your multimeter. This data sheet explains in more detail the makeup of key accessories and offers technical specifications where required. Test leads, probes, and probe tips TL71 Premium Test Lead Set * Included with 8845A and 8846A * One pair (red, black) comfort grip probes with silicone insulated, right-angle test leads * Probe tip size: 2 mm * Recommended for V measurements * CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed. * One-year warranty TL910 Precision Electronic Probe Set * Very small 1 mm tips to access hardto-reach test points * Probe tip length up to 100 mm, test lead length: 1 m * Included : 3 sets of spring loaded gold tips and 2 sets of stainless steel tips * CAT IV 600 V, CAT III 1000 V, 3 A rating * One-year warranty TL80A Basic Electronic DMM Test Set * One pair (red, black) each 1 meter long silicone test lead set, alligator clip and probe tip extender * Probe tip size: 2 mm * C75 soft carrying case * CAT II 300 V. UL listed. * One-year warranty 8845A-TPIT Test Probe IC Tip Set * One pair (red and black) * Snaps onto DMM probes with .080 in (2 mm) O.D. Tips * Designed to IEC 1010 standard * Pin tip jack at the adapter end is recessed for added insulation protection * Adapter allows easy access to leads of through-hole IC's * Insulation at the tip fits between leads to prevent accidental shorting Specifications Materials Color Safety Operating voltage Current Tip: Stainless steel, nickel plated Body: Polypropylene, fire retardant, UL94 V-2 rated One red, one black IEC 1010-2-031, Category II, P2 compliant 300 V rms/dc 3A Test leads, probes, and probe tips cont. 8845A-EFPT Fine Point Extended Test Probe Adapter Set * One pair (red and black) * Snaps onto DMM probes with .080 in (2 mm) O.D. Tips * Designed to IEC 1010 standard * Adapter allows access to hard-to-reach test points * Tips are insulated to the point to prevent shorting of adjacent components Specifications Materials Color Safety Operating voltage Current Tip: Stainless steel Tip insulation: Kynar Body: Polypropylene, fire retardant, UL94 V-2 rated One red, one black IEC 1010-2-031, Category II, P2 compliant 300 V rms/dc 3A TL2X4W-PTII 2X4 Wire Ohms Test Lead * Perform 4wire measurements with only two test leads * Two conductors per lead (one source and one measure) * Excellent resolution and accuracy Specifications Maximum voltage between test lead and ground: 1000 V Maximum transient overvoltage and input voltage combined: 1000 V Maximum current: 500 mA Temperature Operating: 0 to 55 C < 90 % relative humidity Storage: -40 C to 170 C Altitude 2000 m Safety Complies with EN/IED 61010-031 and CAN/CSA C22.2 No. 61010-104 for Measurement Category 1 1000 V 884X-Short 4-wire short * 4-terminal shorting bar * 4 mm banana terminals sized and orientated to short DMM input source and sense terminals * Used to null out front end offsets or as required by the calibration procedure 884x-RTD 100 Ohm RTD Temperature Probe * Manufactured using a coil suspension element design for increased shock and vibration resistance * Mineral-insulated sheath with a minimum bend radius of 19 mm (3/4 in) for flexibility and durability Specifications Resistance Nominal 100 Temperature coefficient 0.00385 / C nominal Temperature range -200 C to 300 C (transition and cable temperature: 0 C to 150 C) Drift rate + 0.13 C at 0 C after 1000 hours at 300 C Sheath material 316 stainless steel Leads TeflonTM-insulated, nickel-plated stranded copper, 22 AWG Termination 4-wire banana Time constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps Bending radius 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip Calibration Includes manufacturer's NIST-traceable calibration and table with R vs. T values in 1 C increments from -196 C to 300 C. Callendar - van Dusen coefficients included Immersion At least 100 mm (4 in) recommended Accuracy (includes cali- 0.050 C at -196 C bration uncertainty and 0.050 C at 0 C short-term stability) 0.051 C at 200 C 0.055 C at 300 C Size 9 in L x 3/16 in diameter Marking Each RTD is marked with the Fluke name and part number Memory 884X-512M 12 Mbyte memory * Used on the 8846A only * Plugs into USB device host port on the 8846A front panel * Fully compliant with Universal Serial Bus Specification v2.0 * Dual LED indicates power and busy status 884X-1G USBMemory 1 GB * Used on the 8846A only * Plugs into USB device host port on the 8846A front panel * Fully compliant with Universal Serial Bus Specification v2.0 * Dual LED indicates power and busy status Interface cables 884X-USB USB to RS-232 Cable Adapter * USB to serial RS-232 interface adapter cable * Converts from standard DB 9-pin serial to USB 2.0 * Requires an available PC communications port * 1.65 m cable length * Includes cable and USB driver disk (CD-ROM) 884X-ETH Ethernet Interface Cable * 8-conductor (4 twisted pair) unshielded cable (48 inches) with an 8-position modular plug (RJ45) on each end, with an overmold boot/strain relief * Rated working voltage: 100 V rms max. * Operating temperature range: -40 C to + 80 C RS43 RS-232 cable * RS43, 2 m * DB9-to-DB9 for PC to unit Y8021 and Y8022 IEEE-488 cables * Shielded IEEE 488 one-meter (39.4 inches) and two-meter (78.8 inches) cables, with plug and jack at each end Software FlukeView Forms * Document, store and analyze individual readings or series of measurements, then convert them into professional-looking documents * FlukeView Forms Basic, included with 8845A/8846A, transfers data points from the meter to a PC, displays readings in table or graphical form * For a larger array of forms, or to use FlukeView(R) Forms Designer to customize your forms, upgrade to FlukeView(R) Forms version 3.0 with FVF-UG Model Name Description FVF-SC5 FlukeView Forms, Basic Software Includes: * CD for FlukeView Forms Basic * Users manual, registration card, and software license agreement FVF-UG FlukeView Forms, Software Upgrade - No Cable Includes: * CD for FlukeView Forms Version 3.0 * Users manual, registration card, and software license agreement FVF-SC4 Extended FlukeView Forms with USB Cable Includes: * CD for FlukeView Forms Version 3.0 * PC-to-meter serial-to-USB adapter cable * Users manual, registration card, and software license agreement FlukeView Forms Requirements Operating system for Windows 98 Second Edition, Windows FVF-SC2 and FVF-Basic Me, Windows 2000, or Windows XP Operating system for Windows 95, Windows 98, Windows FVF-SC1 and FVF-SC3 Me, Windows NT 4.0, Windows 2000, or Windows XP Minimum PC Hardware Pentium class or better microprocessor; 32 MB RAM; 70 MB hard disk space (100 MB to install); Serial or USB port Other accessories Calibration and Service Traceable calibration with data Traceable calibration without data Accredited calibration Repair services Extended warranty agreements Calibration and repair coverage services Product upgrades 884X-CASE * Tough molded plastic case with die cut foam to hold and protect the 8845A or 8846A meter * Accessories and manual compartments One-year warranty * *Contact your local Fluke service center for details and availability Rack Mount Kit * Y8846S allows meter to be mounted in a standard 19inch rack * Y8846D enables mounting two meters sideby-side in a standard 19-inch rack Parts list Quantity Y8846S Y8846D 1 2 1 NA 1 NA 1 1 NA 1 2 2 1 2 4 4 1 2 4 4 Description Small filler plate Large filler plate Large filler plate bracket Rack mount tray Dual center mount #8-32 x 1/2 in panhead Philips screws #6-32 x 1/4 in panhead Philips screws #10-32 x 3/4 in Philips rack screws #6-32 x 1/2 in panhead Philips screws #10-32 rack nuts Fluke. Keeping your world up and running.(R) Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2007 Fluke Corporation. All rights reserved. Information subject to change without notice. Printed in U.S.A. 4/2007 2815866 D-EN-N Rev B Pub_ID: 11205-eng Rev 02