2
PG05400001E
Counters, Panel Meters, Tachometers and Timers
Totalizers
Product Family Overview
Introduction
Totalizers are used in a wide variety of applications where
accurate totals are needed. Typical applications include
counting the number of parts produced, amount of material
used, or the number of machine cycles occurring. Totalizers
are the simplest and most common type of counter. As an
added bonus, some models can perform both totalizing and
ratemeter functions.
Application Example
Parts are fed into a machine or process, an operation is
performed, and the finished parts exit the machine or
process. The subtract totalizer is used to indicate the number
of parts in process.
Totalizer Product Family Overview
Table 1. Product Family Overview
RST
T / R Durant
®
Limit Switch
Limit Switch
Finished Parts
Manufacturing
Process
Raw Parts
Application Example
Product Family Characteristics Typical Applications Panel Cutout
in Inches (mm)
Page
Number
Non-replaceable battery (min. 8-yr. life)
Compact, low cost and high efficiency
8-Digit LCD totalizers
Manual or electrical reset
Various counting modes/inputs
Replacement for mechanical counters
Transaction counting
Parts counting
Position indication or measurement
0.870 x 1.772
(22 x 44)
22
Compact device with bright, LED display
Multiple functions available: count, time,
rate, multifunction, double-function
24V DC Power
Count, measure, time where small package
and easy-to-read display required
Position display
Motor/pulley RPM
0.870 x 1.772
(22 x 44)
24
Economical, multifunction display
Large, LED characters
AC or DC power options
Large, easy-to-read display
Position display
Motor/pulley RPM
1.772 x 1.622
(45 x 92)
27
Replaceable lithium battery
8-digit, high-visibility LCD display
Optional backlighting
Various input options available
Portable/mobile/remote flow monitoring
(e.g. sewer pumping, pesticide application)
Position display, RPM
Length measurement (e.g. carpet, cable)
1.299 x 2.677
(33 x 68)
25
6-digit, super bright LED display
Multiple models available: totalizers,
ratemeters, count controls, digital panel
meters and flow controls
Length measurement and control
Flow monitoring and control
Process monitoring and display
Voltage and current monitoring and display
1.772 x 1.622
(45 x 92)
28
8-digit, high-visibility, 2-line LCD display
User-configurable control inputs
Highly flexible control/display
Flow control where simultaneous total and
rate display are required
Cut-to-length and other simple processes
where flexibility of inputs/outputs required
2.667 x 2.667
(68 x 68)
34
Bright LED display w/14 mm characters
Simple configuration with 14-button tactile
keypad
Many different versions fit almost any
application
Cut-to-length machinery with batching
Parts batching/palletizing
Die press positioning control
Applications where parameter changes are
required
2.667 x 5.433
(68 x 138)
30
Various price, voltage and size ranges for
different duty cycles and environments
Long life and always readable display
Coin-operated equipment
Gaming machines
Printing presses
Secondary machines (e.g. punch press)
Various
Mounting
Configurations
16
Various size ranges for different duty cycles
and environments
No power supply needed
Long life and always readable display
Winding and spooling equipment
Position display
Mechanical piece/cycle counting
Various
Mounting
Configurations
3
E5-024-C
E5-_24-E
E5-496-E
Courier
Eclipse
Ambassador
President
Electromechanical
Mechanical
46
PG05400001E
Counters, Panel Meters, Tachometers and Timers
Count Control
President Series — Durant®
Features
5- or 6-digit, LED display,
0.56" (14 mm)
1, 2 or 3 presets
15V DC @ 100 mA output power
Rear panel screw terminals
20 mA current loop communications
2 Form C relays
Tactile keypad NEMA 4 front panel
Standards and Certifications
UL Listed, CSA marked
CE Marked
Technical Data and Specifications
Table 45. President Series — Count Control Specifications
DC power output is only regulated if unit is powered by AC or greater than 18.5V DC.
Cat. No. 58831400
Description Model
57820400 57820401 58821400 58825400 58831400
AC Power Requirements 120V ±10% 240V ±10% 120V/240V +10%/-20%, 47 – 63 Hz
DC Power Requirements 11 – 30V DC 11 – 28V DC
Power Consumption 8 Watts max. 18 Watts maximum
DC Power Output 15V DC +1/-2 @ 85 mA max. 15V DC +1/-2; 150 mA if powered from AC or less than 24V DC,
100 mA if powered from 24V DC or greater
Operating Temperature 32 to 130°F (0 to 55°C)
Operating Humidity 85% relative, non-condensing
Storage Temperature -10 to 160°F (-40 to 71°C)
Front Panel Rating NEMA 4 rating when mounted with gasket provided
Main Counter Scaler Range N/A 5 Digits (0.0001 to 9.9999)
Count Input Frequency 10 kHz
(5 kHz in Quadrature)
See
Table 46
See
Table 52
See
Table 47
Count Input Impedance 6.8 k1 to 15V DC when control is powered by AC line;
6.8 k1 to 10V DC when control is powered by DC line
Control Input Threshold High 10.5 to 24.5V DC;
Low 0.0 to 4.5V DC when powered by AC
Control Input Impedance 4.5 k1 to +5V DC
Control Input Response Time Min. High 5.3 mS; Min. Low 3.9 mS
Relay Contact Output Ratings SPDT Form C; 10 amps resistive @ 24V DC or 230V AC; 1/3 hp @ 115V AC or 230V AC;
150V DC max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating
Transistor Output Ratings Open collector NPN transistor with Zener diode transient surge protection;
30V DC max. load; 300 mA max. per transistor; 480 mA total for all transistors.
Use 5 mA per relay coil when calculating total transistor current
Communications N/A Dual Port 20 mA current loop, Standard ASCII code
PG05400001E
47
Counters, Panel Meters, Tachometers and Timers
Count Control
President Series — Durant®
Table 45. President Series — Count Control Specifications (Continued)
DC power output is only regulated if unit is powered by AC or greater than 18.5V DC.
Table 46. 58821400 Count Frequency Table 47. 58831400, 58841400, 58861400 Count Frequency
Table 48. 58851400 Count Frequency
Description Model
58841400 58851400 58827400 58827410 58867400
AC Power Requirements 120V/240V +10%/-20%, 47 – 63 Hz
DC Power Requirements 11 – 28V DC
Power Consumption 18 Watts max.
DC Power Output 15V DC +1/-2; 150 mA if powered from AC or less than 24V DC,
100 mA if powered from 24V DC or greater
Operating Temperature 32 to 130°F (0 to 55°C)
Operating Humidity 85% relative, non-condensing
Storage Temperature -10 to 160°F (-40 to 71°C)
Front Panel Rating NEMA 4 rating when mounted with gasket provided
Main Counter Scaler Range 5 Digits (0.0001 to 9.9999) 6 Digits
(0.00001 to 9.99999)
Count Input Frequency See
Table 47
See
Table 48
See
Table 49
See
Table 51
See
Table 50
Count Input Impedance 6.8 k1 to 15V DC when control is powered by AC line;
6.8 k1 to 10V DC when control is powered by DC line
Control Input Threshold High 10.5 to 24.5V DC;
Low 0.0 to 4.5V DC when powered by AC
Control Input Impedance 4.5 k1 to +5V DC
Control Input Response Time Min. High 5.3 mS; Min. Low 3.9 mS
Relay Contact Output Ratings SPDT Form C; 10 amps resistive @ 24V DC or 230V AC; 1/3 hp @ 115V AC or 230V AC;
150V DC max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating
Transistor Output Ratings Open collector NPN transistor with Zener diode transient surge protection;
30V DC max. load; 300 mA max. per transistor; 480 mA total for all transistors.
Use 5 mA per relay coil when calculating total transistor current
Communications Dual Port 20 mA current loop, Standard ASCII code
Scale Factor Count Speed (Pulses per Second)
Nominal Count Quadrature and/or Doubled Count
< 1.0000 6,250 3,125
1.0000 7,500 3,750
1.9999 5,000 2,500
2.0000 6,250 3,125
9.0000 2,500 1,250
9.9999 2,000 1,000
Scale Factor Count Speed (Pulses per Second)
Nominal Count Quadrature and/or Doubled Count
< 1.0000 5,000 2,500
1.0000 7,500 3,750
1.9999 4,000 2,000
2.0000 6,000 3,000
9.0000 2,000 1,000
9.9999 1,500 750
Scale Factor Count Speed (Pulses per Second)
Function 61 value = “0” Function 61 value = “1”
Nominal Count Quadrature and/or Doubled Count Nominal Count Quadrature and/or Doubled Count
< 1.0000 5,000 2,500 3,500 1,750
1.0000 7,500 3,750 4,500 2,250
1.9999 4,000 2,000 2,400 1,200
2.0000 6,000 3,000 3,600 1,800
9.0000 2,000 1,000 1,100 550
9.9999 1,500 750 1,000 500