3 ScotchlokTM Terminals MI18-250DF, MI14-250DF, MI10-250DF W' Female Disconnect, Non-Insulated, Interlock Barrel L Data Sheet Product Number Wire Range (AWG) Mates with Male Tab Width (W ) x Thickness L Barrel Length Barrel I.D. MI18-250DF 22-18 0.250 x 0.032 0.63 0.25 0.076 MI14-250DF 16-14 0.250 x 0.032 0.63 0.25 0.076 MI10-250DF 12-10 0.250 x 0.032 0.64 0.25 0.128 Installation Information WARNING UNDERWRITERS LABORATORIES STANDARD NO. UL 310 3M FILE NO. E70512 CANADIAN STANDARDS ASSOCIATION STANDARD NO. 22.2 NO. 153 3M FILE NO. LR22190 Turn power off before installing or removing terminal. All electrical work should be done according to appropriate electrical codes. UL Listed and CSA Certified for use on stranded copper (AWG) wire only. Strip away the end 3/8 inch of wire insulation. Specifications Wire Size: Barrel Seam: Maximum Voltage Rating: Maximum Current: Terminal Material: Plating: See Table Above Interlock 600 V Building Wire 1000 V signs or fixtures (Luminaires) Same as Wire Brass Tin Make the crimp in the proper station of a recommended 3M crimp tool: TH-440, TH-450 (scissor style), or TR-490 (ratchet style) hand tools. Barrel Crimp (Electrical) Suitable for factory installation on steel or brass tabs, UL and CSA. Suitable for field application on brass tabs, strain relief is required, UL only. Engineering Specification Crimp-Type Female Disconnect shall, electrically and mechanically, connect permanently to a prestripped end of a stranded copper wire: and have a tongue portion with fingers which grip a Male Disconnect in a separable, reusable manner, forming a Quick Connect Wiring Termination. The connector line shall offer tongue variations (sized to grip Male Tabs: 0.250 x 0.032 or 0.187 x 0.020 per ANSI/NEMA CD-2) and barrel variations in wire (AWG) size (22-18, 16-14, 12-10) and construction (non-insulated, vinyl insulated, nylon fully insulated, etc.). The Female Disconnects shall have regulatory agency coverage (UL Listed and CSA Certified). The tongue portion shall be marked with the wire range and manufacturer's symbol (). The Non-Insulated 0.250 Female Disconnect shall be tin plated 0.020 thick brass with a tongue for gripping a 0.250 x 0.032 male tab per ANSI/NEMA CD-2 and a 0.25 long interlocking barrel sized for a specified (AWG) wire range (22-18, 16-14, 12-10). Non-Insulated connectors shall be UL Listed and CSA Certified. Female Disconnects shall be suitable for field or factory wiring, with a UL Recognized strain relief required. 3M and Scotchlok are trademarks of 3M. is a trademark of Underwriters Laboratories. is a trademark of Canadian Standards Association. IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 http://www.3M.com/elpd Litho in USA. (c) 3M 2002 78-8126-0376-5-A