X Series 375 and 500 Watt AC-DC Converters Input range 85...264 V AC with PFC 1 or 2 isolated, regulated outputs up to 96 V 3 kV AC I/O electric strength test voltage LGA * Electrically and mechanically rugged DIN-rail front end * Outputs individually controlled with 150% output peak power * Operating ambient temperature range -40...60C with convection cooling Selection chart for front ends Output 1 Uo nom Io nom [V DC] [A] 24.7 15 24.7 20 37 9.9 37 13.2 49.4 7.5 49.4 10 24.7 10 49.4 5 Output 2 Uo nom Io nom [V DC ] [A] 24.7 10 49.4 5 Input voltage Ui min...Ui max 85...264 VAC (14...440 Hz)3 90...350 VDC Rated power TA = 60C Po tot [W] 375 500 375 500 375 500 500 500 Type Options1 LXR 1601-6 LXN-1601-6 LXR 1701-6 LXN 1701-6 LXR-1801-6 LXN-1801-6 LXN-2660-6 LXN 2880-6 R D1...D5 S M2 F, F1 K2 Selection chart for Battery chargers 2 Output Input voltage Rated power Type Options1 Uo nom Io nom Ui min...Ui max TA = 60C [V DC] [A] Po tot [W] 25.7...29.3 12.6 85...264 VAC 345 LXR 1240-6 M1 F, F1 25.7...29.3 16.9 460 LXN 1240-6 M1 K2 (14...440 Hz)3 51.4...58.6 6.3 90...350 VDC 345 LXR 1740-6 M1 51.4...58.6 8.4 460 LXN 1740-6 M1 1 For lead times and minimum order quantities contact Power-One. 2 For availability contact Power-One. 3 Input frequency range certified for 14...440 Hz. For continuous operating frequency <40 Hz and >100 Hz contact factory. www.power-one.com Edition 5/7.2001 1 X Series 375 and 500 Watt AC-DC Converters Input Input voltage Input frequency Power factor Inrush current world wide mains, single phase for derating information see application note wide frequency range active PFC virtually no inrush current 85...264 V AC 90...350 V DC 16 2/3...440 Hz up to 0.99 Output Efficiency Output voltage setting accuracy Output voltage noise Output voltage ripple Line and cross regulation Load regulation Minimum load Current limitation Short term peak power Operation in parallel Hold-up time Ui nom, Io nom up to 89% Ui nom, Io nom 1.3% Uo nom IEC/EN 61204 typ. 50 mV sinusoidal output ripple at twice the line frequency 1.2 Vpp Ui min...Ui max typ. 50 mV 0...100 % Io nom, Ui nom -1.6% Uo nom not required rectangular U/I characteristic 101...112% Io nom 1 s, electronically controlled 150% Io nom enabled by droop current share Io nom, Uo decreases to 80% of Uo nom typ. 15 ms Control Status indication LED output(s) OK Protection Input reverse polarity Input fuse Input undervoltage lockout Input overvoltage lockout Input transient Output(s) Output overvoltage Overtemperature bridge rectifier not user accessible 10 A, fast blow typ. 80% Ui min typ. 105% Ui max voltage depending resistor (VDR) no-load, overload and short circuit proof second control loop, each output, 24/48 V reduced output power if thermally overloaded 30/60 V SELV Safety Approvals in progress Electric strength test voltage Pollution degree Degree of protection www.power-one.com Edition 5/7.2001 EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed class I, I/case class I, I/O class I, O/case class I, O/O AC-in / DC-in 2 kV AC 3 kV AC 1 kV AC 0.35 kV AC 3/2 IP 20 2 DIN Rail Mountable X Series EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN 61000-4-4, IEC/EN 61000-4-5, level 4, contact/air (8/15 kV) criterion A level 3 (10 V/m) criterion A level 4, capacitive/direct (4/2 kV) criterion A level 3, in and out, line to line (2 kV) criterion B level >3, input, line to case (3.5 kV) criterion B level 2, output, line to case (1 kV) criterion A IEC/EN 61000-4-6, level 3 (10 V) criterion A CISPR 22/EN 55022, conducted class B Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Shock and vibration Shock Bump Vibration, sinusoidal Vibration, random MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40C unit wall mounted with brackets IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-29, 11 ms IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217E, GB, 40C -40...60C -40...87C -40...100C 56 days 50 gn 25 gn 0.35 mm/5 gn 0.05 g2/Hz 400'000 h Options Input and output undervoltage monitoring Output voltage adjustment 10 V...110% of Uo nom Remote on/off Multi option choice (D1...D5, R, S) via Sub-D connector Built-in second input fuse in the neutral No fuse fittet (for operation from high DC) System connectors with screw terminals www.power-one.com Edition 5/7.2001 D1...D5 R S M1...M2 F F1 K2 3 X Series 375 and 500 Watt AC-DC Converters Mechanical data European Projection 33 (1.3") 43 (1.69") 13 (0.51")) Option M S09127 49 (1.93") 204 (8.03") ( ) 196 (7.71") ( ) 194 (7.64") ( ) 29.4 (1.16") 138 (5.43") 5 113.6 (4.47") 106.6 (4.2") 15 (0.59") Tolerances 0.3 mm (0.012") unless otherwise indicated. 31 (1.22") TA TA Wall mounting brackets (accessory) Measuring point for case temperature TC www.power-one.com Edition 5/7.2001 4 DIN Rail Mountable X Series Terminal allocation input side n Pin 1 2 3 Des. N P Determination Protective earth Input neutral I 1 Terminal allocation output side Pin Des. Single output Double output 1 2 3 4 5 6 7 8 9 10 + + - - + + - - Aux1 Earth to load Output pos. Output pos. Output neg. Output neg. Output pos. Output pos. Output neg. Output neg. Options Earth to load Output 1 pos. Output 1 pos. Output 1 neg. Output 1 neg. Output 2 pos. Output 2 pos. Output 2 neg. Output 2 neg. Options 11 Aux2 12 S10066 Options Options Earth to load Earth to load 2 3 S90048 1 2 3 4 5 6 7 8 9 10 11 12 Accessories Mounting brackets for vertical chassis/wall mounting Protective covers over input and output terminals www.power-one.com Edition 5/7.2001 5