Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: • 15.04.2004
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition:
Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Inductive sensor
Bi5U-M18-AP6X-H1141
threaded barrel, M18 x 1
chrome-plated brass
factor 1 for all metals
magnetic field immune
extended temperature range
high switching frequency
3-wire DC, 10...30 VDC
normally open pnp output
connector, M12 x 1
Wiring diagram
Function principles
Inductive proximity switches are designed
for wear-free non-contact detection of me-
tal objects. Due to a ferrite-less 3-coil sy-
stem, Uprox factor 1 sensor have distinct
advantages. The detect all metals at the
same switching distance, are magnetic
field immune and feature large switching di-
stances.
1 BN
3 BU
4 BK
+
pnp
4 BK
3 BU 1 BN
2
Type Bi5U-M18-AP6X-H1141
Ident-No. 1635140
Rated operating distance Sn 5 mm
Mounting mode flush
Hysteresis (switching distance) 3... 15 %
Min. repeat accuracy 2 %
Temperature drift ± 10 %
± 15 %, -25 °C v +70 °C
Operating temperature -30 ...+ 85 °C
Rated operational voltage (DC) UB10... 30 VDC
Max. ripple 10 % Upp
Rated operational current (DC) Ie 200 mA
No-load current I0 15 mA
Max. OFF-state current 0,1 mA
Max. switching frequency 2,5 kHz
Rated insulation voltage 0,5 kV
Output function 3-wire, normally open, PNP
Short-circuit protection yes, cyclic
Max. voltage drop at Ie 1,8 V
Wire breakage / reverse polarity protection yes / complete
Protection class ÷
Housing style threaded barrel; M18 x 1
Dimensions 52 mm
Housing material metal, CuZn, chrome-plated
Active face plastic, PBT
Max. fixing torque of coupling nut 25 Nm
Wiring connector, M12 x 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 x g (11 ms)
Degree of protection IP67
Switching status indication LED yellow
24/4
36
52
LED
M18 x 1
9
M12 x 1
Hans Turck GmbH & Co.KG • Postfach D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: • 15.04.2004
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition:
Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Inductive sensor
Bi5U-M18-AP6X-H1141
Mounting instructions minimum gap
Gap D 2 x B
Gap W 3 x Sn
Gap T 3 x B
Gap S 1,5 x B
Gap G 6 x Sn
Diameter of active face B Ø 18 mm
W
G
D
S
T
Hans Turck GmbH & Co.KG • Postfach D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: • 15.04.2004
Accessories
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition:
Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Inductive sensor
Bi5U-M18-AP6X-H1141
Typ Ident-
No.
Description Dimension drawing
QM-18 6945102 quick-mount fixing clamp with dead-stop; material:
chrome-plated brass external thread M24 x 1,5.
BST-18B 6947214 fixing clamp with dead-stop; material: PA6
30/5
ø 18
36
20,5
ø 18
24
30
28 40
M5
20