3PS8871C 10/03/07
PI2PCIE2422
PCI Express Gen II Compliant, 8-Differential
Channel Switch with 8:4 Mux/DeMux Option
Storage Temperature ....................................................... –65°C to +150°C
Supply Voltage to Ground Potential ................................... –0.5V to +2.5V
DC Input Voltage .................................................................. –0.5V to VCC
DC Output Current .......................................................................... 120mA
Power Dissipation .............................................................................. 0.5W
Note: Stresses greater than those listed under MAX I MUM
RAT INGS may cause permanent damage to the de vice. This
is a stress rating only and func tion al op er a tion of the device
at these or any other conditions above those indicated in the
operational sections of this spec i fi ca tion is not implied. Ex-
posure to absolute max i mum rating con di tions for extended
periods may affect re li abil i ty.
Maximum Ratings
(Above which useful life may be impaired. For user guide lines, not tested.)
DC Electrical Characteristics for Switching over Operating Range (TA = –40°C to +85°C, VCC = 1.5V to 2.0V)
Paramenter Description Test Conditions Min Typ(1) Max Units
VIH Input HIGH Voltage Guaranteed HIGH level 0.65 x VCC
VVIL Input LOW Voltage Guaranteed LOW level –0.5 0.35 x VCC
VIK Clamp Diode Voltage VCC = Max., IIN = –18mA –0.7 –1.2
IIH Input HIGH Current VCC = Max., VIN = VCC ±5 μA
IIL Input LOW Current VCC = Max., VIN = GND ±5
RON On Resistance VCC = Min., VIN = 1.3V, IIN = 40mA 10 Ohm
CON(AB) Capacitance on A/B, C/D VIN = 0, VCC = 1.8V 3.0 pF
Note:
1. Typical values are at VCC = 1.8V, TA = 25°C ambient and maximum loading.
Dynamic Electrical Characteristics Over the Operating Range (TA= -40º to +85ºC, VCC = 1.8V±10%, GND=0V)
Parameter Description Test Conditions Min. Typ.(1) Max. Units
XTALK Crosstalk See Fig. 1 for Measurement Setup, f = 3.00 GHz
f = 100 MHz
–35
–70
dBOIRR OFF Isolation See Fig. 2 for Measurement Setup, f = 3.00 GHz
f = 100 MHz
–26
–60
ILOSS Differential Inser-
tion Loss f = 3 GHz -3
BW Bandwidth (-3dB) 3.4 GHz
Notes:
1. Guaranteed by design. Typical values are at VCC = 1.8V, Ta = 25°C ambient and maximum loading.
Power Supply Characteristics
Parameters Description Test Conditions(1) Min. Typ.(2) Max. Units
ICC Quiescent Power Supply Current VCC = Max., VIN = GND or VCC 200 μA
Notes:
1. For Max. or Min. conditions, use appropriate value specifi ed under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 1.8V, TA = 25°C ambient and maximum loading.