1
Photoelectric sensor in compact M18 housing
E3F1
M18 size Photoelectric sensor with best value at competitive price
Bright visible red LED enabling easy alignment
Compact and robust housing for easy integration into machines
Reliable operation in all industrial environments
Ordering Information
Sensors [Refer to Dimensions on page 5.]
Reflectors [Refer to Dimensions on page 6.]
Reflectors required for Retro-reflective Sensors: A Reflector is not provided with the Sensor. Be sure to order a Reflector separately.
Mounting brackets [Refer to Dimensions on page 6.]
A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required.
Sensor type Sensing distance Connection method Model
NPN output PNP output
Through-beam pre-wired E3F1-TN11 2M*1
*1 Includes the emitter and rece iver.
E3F1-TP11 2M*1
M12 connector E3F1-TN21*1 E3F1-TP21*1
Retro-reflective*2
*2 The Reflector is sold separately.
pre-wired E3F1-RN11 2M E3F1-RP11 2M
M12 connector E3F1-RN21 E3F1-RP21
Diffuse-reflective pre-wired E3F1-DN11 2M E3F1-DP11 2M
M12 connector E3F1-DN21 E3F1-DP21
pre-wired E3F1-DN12 2M E3F1-DP12 2M
M12 connector E3F1-DN22 E3F1-DP22
Red light
15 m
0.1 to 3 m
with E39-R1S
100 mm
300 mm
Sensor Sensing distance Appearance Model Quantity Remarks
E3F1-R@0.1 to 3 m E39-R1S 1for E3F1-R@
Sensor Appearance Model (Material) Quantity Remarks
all types
E39-L183 (SUS304) 1 Mounting bracket
E39-L182 (POM) 1 Flush mounting bracket
E3F1
2
Sensor I/O connectors
Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
Specifications
Sensor Size Cable Appearance Cable type Model
M12 connector types M12 Standard
2 m
4-wire
XS2F-M12PVC4S2M-EU
5 m XS2F-M12PVC4S5M-EU
2 m XS2F-M12PVC4A2M-EU
5 m XS2F-M12PVC4A5M-EU
Sensing method Through-beam Retro-reflective Diffuse-reflective
Model NPN
output Pre-wired E3F1-TN11 2M E3F1-RN11 2M E3F1-DN11 2M E3F1-DN12 2M
M12 Connector E3F1-TN21 E3F1-RN21 E3F1-DN21 E3F1-DN22
PNP
output Pre-wired E3F1-TP11 2M E3F1-RP11 2M E3F1-DP11 2M E3F1-DP12 2M
Item M12 Connector E3F1-TP21 E3F1-RP21 E3F1-DP21 E3F1-DP22
Sensing distance 15 m 0.1 to 3 m
(with E39-R1S)100 mm
(white paper:
300 300 mm)
300 mm
(white paper:
300 300 mm)
Spot diameter (typical) ——
40
45 mm
Sensing distance
of 100 mm
40
50 mm
Sensing distance
of 300 mm
Directional angle 2° min. 2° min.
Light source (wavelength) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 40 mA max.
(Emitter 25 mA max.
Receiver 15 mA max.) 25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator Operation indicator (orange)
Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits Reversed power supply polarity protection, Output short-circuit protection and Reversed output po-
larity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient temperature range Operating: -25 to 55°C/ Storage: -30 to 70°C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%RH/ Storage: 35 to 95%RH (with no condensation)
Degree of protection IEC: IP66
Weight
(packed
state/only
sensor)
Pre-wired cable (2M) Approx. 110 g/
Approx. 50 g,
respectively Approx. 60 g/ Approx. 50 g
Connector Approx. 30 g/
Approx. 10 g,
respectively Approx. 20 g/ Approx. 10 g
Material
Case ABS
Lens and Display PMMA
Adjuster POM
Nut ABS
Accessories Instruction sheet
M18 nuts (4 pcs) Instruction sheet
M18 nuts (2 pcs)
Straight
Angle
E3F1
3
Output circuit diagram
PNP Output
NPN Output
Connector Pin Arrangement
M12 Connector Pin Arrangement Connectors (Sensor I/O connectors)
M12 4-wire Connectors
Model Operation
mode Timing charts Operation
selector Output circuit
E3F1-TP@
E3F1-RP@
E3F1-DP@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
or open the
pink wire
(Pin(2))
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between blue
and black leads)
Output transistor
Load
(e.g., relay)
4
3
2
1
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON 0 V
Operation
indicator
(Orange)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
10 to 30 VDC
Brown
Black
Blue Load
(Relay)
Through-beam Receivers, Retro-reflective Models,
Diffuse-reflective Models
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between blue
and black leads)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
Model Operation
mode Timing charts Operation
selector Output circuit
E3F1-TN@
E3F1-RN@
E3F1-DN@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
or open the
pink wire
(Pin(2))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between brown
and black leads)
Output transistor
Load
(e.g., relay)
4
3
2
1
10 to 30 VDC
Brown
Black
Blue
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
Operation
indicator
(Orange)
Stability
indicator
(Green)
0 V
Load
(Relay)
Photo-
electric
Sensor
Main
Circuit
Through-beam Receivers, Retro-reflective Models,
Diffuse-reflective Models
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between brown
and black leads)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
3
1
24
Classification Wire color Connector pin No. Application
DC
Brown Power supply (+V)
White L/on · D/on selectable
Blue Power supply (0 V)
Black Output
2
4
13
1
2
3
4
Brown
Blue
White
Black
Pin No. Wire color
E3F1
4
Nomenclature
* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for directly or
indirectly ensuring safety of persons. Do not use it
for such a purpose.
Never use the product with an AC power supply.
Do not use the product with voltage in excess of the
rated voltage.
Do not use the product with incorrect wiring.
Otherwise, explosion, fire, malfunction may result.
Be sure to follow the safety precautions below for added safety.
1. Do not use the sensor under the environment with explosive,
flammable or corrosive gas.
2. Do not use the sensor under the oil or chemical environment.
3. Do not use the sensor in the water, rain or outdoors.
4. Do not use the sensor in the environment where humidity is high
and condensation may occur.
5. Do not use the sensor under the environment under the other
conditions in excess of rated.
6. Do not use the sensor in place that is exposed by direct sunlight.
7. Do not use the sensor in place where the sensor may receive
direct vibration or shock.
8. Do not use the thinner, alcohol, or other organic solvents.
9. Never disassemble, repair nor tamper with the sensor.
10.Please process it as industrial waste.
1. Laying Sensor wiring in the same conduit or duct as high-voltage
wires or power lines may result in malfunction or damage due to
conduit or use shielded cable.
2. Do not pull on the cable with excessive force.
3. If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
4. The sensor will be available 100 ms after the power supply is tuned
ON. Start to use the sensor 100 ms or more after turning ON the
power supply. If the load and the sensor are connected to separate
power supplies, be sure to turn ON the sensor first.
5. Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
supply for the load or the load line.
6. The sensor must be mounted using the provided nuts. The proper
tightening torque range is between 0.4 and 0.5 N·m.
Straight
with an adjuster:
E3F1-T@-D
E3F1-R@
E3F1-D@
without an adjuster:
E3F1-T@-L *
WARNING
CAUTION
Precautions for Safe Use
Precautions for Correct Use
E3F1
5
Dimensions
Sensors
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
2
M18 × 30.5 P=1
Operation indicator (orenge)
Sensitivity adjuster *
7 dia. 18.5 dia.
+0.5
0
Sensitivity indicator (green)
Vinyl insurated round cord 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
Receiver
Emitter Optical axisOptical axis
34.5
23
30.5
41
15 15
16.6 dia.
7
Pre-wired Models
E3F1-T@
E3F1-R@
E3F1-D@
Suitable models
E3F1-T@11 Suitable models
E3F1-R@11
E3F1-D@1@
* Suitable models
E3F1-T@11-D
E3F1-R@12
E3F1-D@1@
Mounting HolesLeft side view Left side view
Front view
M12 Connector Models
E3F1-T@
E3F1-R@
E3F1-D@
2
M18 × 30.5 P=1
M12 × 4 P=1
7 dia. 18.5 dia.
+0.5
0
34.5
23
30.5
15 15
16.6 dia.
7
1
2
34
Operation indicator (orenge)
Sensitivity adjuster *
Sensitivity indicator (green)
Receiver
Emitter Optical axisOptical axis
45
Suitable models
E3F1-T@21 Suitable models
E3F1-R@21
E3F1-D@2@
Mounting Holes
Terminal No. Specification
1+V
2 L/on · D/on selectable
30V
4 Output
* Suitable models
E3F1-T@21-D
E3F1-R@22
E3F1-D@2@
Left side view Left side view
Front view Right side view
Three, 22
24 dia.
M18 × 7.5 P=1
8
Attached nut
E3F1
6
Accessories (Order Separately)
34
40.3
5259.9
2.7
8
1.6
7.5
7
Two, 3.5 dia.
Reflectors
E39-R1S
4.3
37
16
23
36.5
20
Two, 30°
Two, 4.3
Two, R15
42
1.5 90°
(R16.5)
18.2 dia.
14.5
15.1
12.5
16.7 dia.
27 dia.
Mounting brackets
E39-L183 Mounting brackets
E39-L182
E3F1
7
Read and Und erstand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUY ER OR USER ACKNOWLEDGES TH AT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMIT ATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT T O CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUIT A BILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, sy stem, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separa te indu stry or gov ernm ent regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVI NG SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRA M MA BLE PRODU CTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
C H ANGE IN S P ECIF IC AT IONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMA NCE DAT A
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
In the interest of product impr o vement, specifications are subject to change without notice.Cat. No. E94E-EN-01
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.industrial.omron.eu