* * * * * * * Features Unregulated Converters 3 Watt in a SIP4 package 1-3kVDC isolation Efficiency up to 90% -40C to +100C operating temperature range IEC/EN/UL60950 certified CB Report Industry standard pinout Description The RI3 series has been specifically designed for applications where board space is at a premium since these 3 Watt converters have the same foot print as the RI series 2 Watt converters. With efficiencies up to 90%, the full output power is available over the operating temperature range -40C to +85C and the converters can be used in ambient temperatures of up to 100C with derating. The wide selection of input voltage and output voltage options plus an I/O-Isolation of 1kVDC, 2kVDC or 3kVDC makes these converters suitable for many industrial applications. DC/DC Converter RI3 3 Watt SIP4 Single Output Selection Guide Part Number RI3-0505S Input Voltage [VDC] Output Voltage [VDC] Output Current [mA] 5 5 600 Efficiency max. Capacitive typ. @ full load Load (1) [%] [F] 83 2200 RI3-0509S 5 9 333 86 1200 RI3-0512S 5 12 250 87 1000 RI3-0515S 5 15 200 88 820 RI3-1205S 12 5 600 85 2000 RI3-1209S 12 9 333 88 1200 RI3-1212S 12 12 250 89 1000 RI3-1215S 12 15 200 89 820 RI3-1505S 15 5 600 85 2000 RI3-1509S 15 9 333 88 1200 RI3-1512S 15 12 250 88 1000 RI3-1515S 15 15 200 88 820 RI3-2405S 24 5 600 86 2000 RI3-2409S 24 9 333 89 1200 RI3-2412S 24 12 250 90 1000 RI3-2415S 24 15 200 90 820 E224736 IEC/EN60950-1 certified UL60950-1 certified CSA C22.2 NO. 60950 certified EN55032 compliant Notes: Note1: Max. capacitive load is tested at nominal input and constant resistive load Model Numbering RI3-__ __ _/_ Input Voltage Output Voltage Isolation (2) Single Notes: Note2: add suffix "/H2" for 2kVDC/1second or "/H3" for 3kVDC/1second isolation without suffix standard 1kVDC/1second isolation Examples: e.g. RI3-1212S, Single Output, 12Vin and 12Vout, 1kVDC isolation e.g. RI3-1212S/H2, Single Output, 12Vin and 12Vout, 2kVDC isolation e.g. RI3-1212S/H3, Single Output, 12Vin and 12Vout, 3kVDC isolation www.recom-power.com e.g. RI3-2405S, Single Output, 24Vin and 5Vout, 1kVDC isolation e.g. RI3-2405S/H2, Single Output, 24Vin and 5Vout, 2kVDC isolation e.g. RI3-2405S/H3, Single Output, 24Vin and 5Vout, 3kVDC isolation REV.: 2/2018 ECO-1 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition 5VDC 12VDC nom. Vin= 15VDC 24VDC Input Voltage Range Internal Operating Frequency Minimum Load Min. Typ. Max. 4.5VDC 10.8VDC 13.5VDC 21.6VDC 5VDC 12VDC 15VDC 24VDC 5.5VDC 13.2VDC 16.5VDC 26.4VDC 20kHz 40kHz 0% (3) Output Ripple and Noise (4) 20MHz BW 50mVp-p 100mVp-p Notes: Note3: Operation below no load won`t harm the converter, but specifications may not be met Note4: Measurements are made with a 100nF MLCC across output (low ESR) Efficiency vs. Load RI3-12xxS 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RI3-05xxS 60 50 40 30 10 0 10 20 30 40 50 60 70 80 90 40 10 0 100 80 80 70 70 60 50 40 30 20 10 50 60 40 50 60 70 80 90 70 80 100 50 40 2405 2409 2412 2415 10 100 90 60 20 Output Load [%] www.recom-power.com 40 30 1505 1509 1512 1515 30 30 RI3-24xxS 90 20 20 RI3-15xxS 100 10 10 Output Load [%] 90 0 0 Output Load [%] 100 0 1205 1209 1212 1215 20 Efficiency [%] Efficiency [%] 0 50 30 0505 0509 0512 0515 20 60 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REV.: 2/2018 ECO-2 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) REGULATIONS Parameter Condition Output Accuracy 5Vout all other Line Regulation low line to high line Load Regulation Values 3.0% min. / 4.0% typ. 2.0% min. / 3.0% typ. 1.2% max. @ 1.0% of Vin 5Vout all other 10% to 100% load 8.0% typ. / 10.0% max. 6.0% typ. / 10.0% max. Accuracy vs. Load RI3-xx05S RI3-xx09S 30 30 0505 1205 1505 2405 Deviation [%] 20 15 20 10 5 15 10 5 0 0 -5 -5 -10 0 10 20 30 40 50 60 70 80 90 0509 1209 1509 2409 25 Deviation [%] 25 -10 100 0 10 20 30 Output Load [%] 40 RI3-xx12S 70 80 90 100 RI3-xx15S 30 0512 1212 1512 2412 20 15 20 10 5 15 10 5 0 0 -5 -5 0 10 20 30 40 50 60 70 80 90 0515 1215 1515 2415 25 Deviation [%] 25 Deviation [%] 60 Output Load [%] 30 -10 50 -10 100 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Isolation Voltage Condition tested for 1 second standard without suffix with suffix "/H2" with suffix "/H3" Isolation Capacitance 1kVDC 2kVDC 3kVDC 37pF typ. / 130pF max. Isolation Resistance www.recom-power.com Value 10G min. REV.: 2/2018 ECO-3 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @ natural convection 0.1m/s (see graph) -40C to +85C Maximum Case Temperature +115C Operating Humidity non-condensing 5% - 95% RH max. Vibration MIL-STD-202G MTBF 4395 x 103 hours 1740 x 10 hours +25C +85C according to MIL-HDBK-217F, G.B. Derating Graph (@ Chamber and natural convection 0.1m/s) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 Ambient Temperature [C] 85 SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Information Technology Equipment - General Requirments for Safety (CB Scheme) E224736-A31 Information Technology Equipment - General Requirments for Safety E224736-A32 EAC Standard IEC60950-1, 2nd Edition, 2013 EN60950-1, 2nd Endition, 2013 UL60950-1, 2nd Edition, 2014 C22.2 No. 60950-1-07, 2nd Edition, 2014 RU-AT.49.09571 TP TC 004/2011 RoHs2+ RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Standard / Criterion without external filter with external filter Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements EN55032, Class A EN55032, Class B EMC Filtering Suggestions according to EN55032 Class B C2 L1 +Vin +Vout DC C1 DC -Vin www.recom-power.com -Vout REV.: 2/2018 Component List Class B MODEL C1 C2 L1 RI3-05xxS 4.7F 470pF/4kV 10H Choke RI3-12xxS 4.7F 470pF/4kV 10H Choke RI3-15xxS RI3-24xxS 2.2F 470pF/4kV 10H, Choke ECO-4 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting non conductive plastic, (UL94 V-0) silicone, (UL94 V-0) Package Dimension (LxWxH) 11.5 x 10.2 x 7.6mm Package Weight 2.2g typ. Dimension Drawing (mm) Pin Connections Pin # Function 1 -Vin 2 +Vin 3 -Vout 4 +Vout embossed logo 7.6 Tolerance: xx.x= 0.5mm xx.xx= 0.35mm Pin pitch: 0.25mm Marking 0.51 10.2 11.5 1 2 3 4 Bottom View 0.85O 2.54 Recommended Footprint Standard H3 Version 0.85O +0.15/-0 2.54 7.62 1.00 Recommended Footprint Standard H2 Version 1.00 O +0.15/-0 Top View 1.27 2.00 0.250.05 4.10 0.75+0.10/-0.05 1.80 solder pad for /H3 models Top View 1 2 3 4 1 2 3 4 2.54 2.54 PACKAGING INFORMATION Packaging Dimension (LxWxH) tube Packaging Quantity 520.0 x 9.3 x 16.5mm 42pcs Storage Temperature Range -55C to +125C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 2/2018 ECO-5