Legacy General Purpose Relays Catalog 2017 Contents Legacy General Purpose Relays bb Series Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bb 792 Control Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 bb 781R Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 bb 782 Power Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 bb 783 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 bb 784 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 bb 750R Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 bb 788R Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 bb 782H Hazardous Location Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 bb 750H Hazardous Location Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 bb UL Listed Relay/Socket Combinations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 bb Sockets vv Socket Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 vv Mounting Adapter Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 bb Socket Accessories vv Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 vv Hold-Down Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 vv Insulated Coil Bus Jumper System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 vv DIN Rail and DIN Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 vv ID Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 vv Panel Mount Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 bb Socket Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 bb Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 bb Website Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 2 Legacy General Purpose Relays Series Overview Designed with specialized magnetic armatures and coils, our general purpose relays easily handle current loads ranging from 10-15 A. With multiple features, and a broad line of sockets and accessories, these relays offer options to improve design, speed up installation, and simplify testing of your application. Key Features bb Socket, panel, and DIN mounting options bb Multiple features and contact configurations available bb Optional protection, mounting, and identification accessories bb Ideal choice for direct replacement in MRO applications (maintenance, repair, and operations) bb UL Class I Division 2 models for hazardous locations Series Features Terminals Contact Configuration Output Current Page 792 Control Plug-In Relay Blade DPDT and 4PDT 3-12 A 4 781R Plug-In Relay Blade SPDT 15 A 9 782 Power Plug-In Relay Blade DPDT 15 A 13 783 Plug-In Relay Blade 3PDT 15 A 17 784 Plug-In Relay Blade 4PDT 15 A 21 Octal (8 Pin) DPDT 10 A Octal (11 Pin) 3PDT 10 A Blade DPDT and 3PDT 10 A 750R 788R Plug-In Relay Plug-In Relay 25 29 5A 782H Hermetically Sealed Relay Blade 4PDT 3A 33 1A 750H Hermetically Sealed Relay Octal (8 Pin) DPDT 12 A Octal (11 Pin) 3PDT 12 A 37 3 Legacy General Purpose Relays Description 792 Control Series DPDT 12 A; 4PDT 6 A and 3 A Description UL Listed when used with corresponding sockets 792 Clear Cover Contact Rating Contact Configuration 3A 4PDT 12 A DPDT 6A 4PDT 792 Full-Feature Cover The 792 plug-in control relays offer clear or full-feature covers with multiple mounting options and accessories. The 4PDT models save valuable space while adding increased functionality. Feature Benefit 12 A / 6 A / 3 A switching current Ideal choice for various automation panels and controls Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button to facilitate maintenance and speed up commissioning DPDT and 4PDT contact options Simultaneous control of 2 or 4 separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the status of an unpowered relay during testing or operation Nominal Coil Voltage Coil Resistance () 12 Vac 24 Vac 48 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 12 Vac 24 Vac 48 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 12 Vac 24 Vac 48 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 44 177 708 3630 17720 160 640 2560 13440 44 177 708 3630 17720 160 640 2560 13440 44 177 708 3630 17720 160 640 2560 13440 Contacts Low-Level Bifurcated Standard Clear Cover Part Number Clear Cover with LED Full-Feature Cover 792XDX3C-12A 792XDX3C-24A 792XDX3C-48A 792XDX3C-120A 792XDX3C-240A 792XDX3C-12D 792XDX3C-24D 792XDX3C-48D 792XDX3C-110D 792XBXC-12A 792XBXC-24A 792XBXC-48A 792XBXC-120A 792XBXC-240A 792XBXC-12D 792XBXC-24D 792XBXC-48D 792XBXC-110D 792XDXC-12A 792XDXC-24A 792XDXC-48A 792XDXC-120A 792XDXC-240A 792XDXC-12D 792XDXC-24D 792XDXC-48D 792XDXC-110D 792XDX3CL-12A 792XDX3CL-24A 792XDX3CL-48A 792XDX3CL-120A 792XDX3CL-240A 792XDX3CL-12D 792XDX3CL-24D 792XDX3CL-48D 792XDX3CL-110D -- -- -- -- -- -- -- -- -- 792XDXCL-12A 792XDXCL-24A 792XDXCL-48A 792XDXCL-120A 792XDXCL-240A 792XDXCL-12D 792XDXCL-24D 792XDXCL-48D 792XDXCL-110D 792XDX3M4L-12A 792XDX3M4L-24A 792XDX3M4L-48A 792XDX3M4L-120A 792XDX3M4L-240A 792XDX3M4L-12D 792XDX3M4L-24D 792XDX3M4L-48D 792XDX3M4L-110D 792XBXM4L-12A 792XBXM4L-24A 792XBXM4L-48A 792XBXM4L-120A 792XBXM4L-240A 792XBXM4L-12D 792XBXM4L-24D 792XBXM4L-48D 792XBXM4L-110D 792XDXM4L-12A 792XDXM4L-24A 792XDXM4L-48A 792XDXM4L-120A 792XDXM4L-240A 792XDXM4L-12D 792XDXM4L-24D 792XDXM4L-48D 792XDXM4L-110D Part Number Explanation Series: 792 = 792 Series Control Relay Coil Voltages: 12-240A = 12-240 Vac 12-110D = 12-110 Vdc Cover Options: Contact Configuration: C = Clear Cover CL = Clear Cover and LED XBX = DPDT M4L = Locking Push Button Contact Code: XDX = 4PDT and LED None = Standard 6-12 A Silver Alloy Contacts 3 = 3 A Bifurcated Contacts 4 For more information, contact customer service (1-847-441-2540). Specifications Legacy General Purpose Relays 792 Control Series DPDT 12 A; 4PDT 6 A and 3 A Specifications Part Number 792XBX Contact Characteristics Terminal Style Blade Contact Material Silver Alloy Contact Configuration DPDT Carrying Current 12 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc Rated Switching Current (Conforming to IEC AC-1 and DC-1) N.O.: 12 A at 250 Vac, N.C.: 6 A at 250 Vac N.O.: 12 A at 28 Vdc, N.C.: 6 A at 28 Vdc Rated Switching Current Resistive (Conforming to UL) 12 A at 277 Vac,100 k cycles 12 A at 120 Vac, 200 k cycles 12 A at 30 Vdc,100 k cycles Motor 1/2 hp at 120 Vac, 6 k cycles 1 hp at 277 Vac, 6 k cycles B300 Pilot Duty 6 k cycles Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 80% (AC/DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption 0.9-1.2 VA (AC); 0.8-1.1 W (DC) General Characteristics Electrical Life at Rated Load 200,000 operations (where stated) Mechanical Life (Unpowered) 10,000,000 operations Operating Time 25 ms max. at 80% rated coil voltage 20 ms max. at 100% rated coil voltage Release Time 20 ms max. (DC) 35 ms max. (AC) Impulse Withstand Voltage Dielectric Strength 4 kV (1.2 / 50 s) Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1300 V (rms) Ambient Air Temperature Storage Around the Device Operation -40 to +85 C (-40 to +185 F) Vibration Resistance In Operation 3 gn at 35-150 Hz Not Operating 5 gn at 35-150 Hz In Operation 10 gn Not Operating 30 gn Shock Resistance -40 to +55 C (-40 to +131 F) Degree of Protection (Housing Only) IP40 Weight 37 g (1.31 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 5 Specifications (cont.) Legacy General Purpose Relays 792 Control Series DPDT 12 A; 4PDT 6 A and 3 A Specifications (continued) Part Number 792XDX 792XDX3 Contact Characteristics Terminal Style Blade Blade Contact Material Silver Alloy Bifurcated Contact Configuration 4PDT 4PDT Carrying Current 6A 3A Load Type Standard Low Level Maximum Switching Voltage 300 V 300 V Rated Switching Current 250 Vac (Conforming to IEC AC1 and DC1) 28 Vdc N.O.: 6 A; N.C.: 3 A N.O.: 2 A; N.C.: 1 A N.O.: 6 A; N.C.: 3 A N.O.: 2 A; N.C.: 1 A Switching Current (Conforming to UL) General Purpose -- 3 A at 240-277 Vac 3 A at 120 Vac Resistive 6 A at 277 Vac, 200 k cycles 8 A at 120 Vac, 200 k cycles 8 A at 30 Vdc, 200 k cycles 3 A at 30 Vdc Motor 1/3 hp at 120 Vac, 6 k cycles 1/2 hp at 277 Vac, 6 k cycles 1/16 hp (2.8 A FLA) at 120 Vac Pilot Duty B300, 6 k cycles 5 A make, 0.5 A break, 3 A continuous at 120 Vac 10 mA at 17 Vdc 3 mA at 5 Vdc Minimum Switching Requirement Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 80% (AC/DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption 0.9-1.2 VA (AC); 0.8-1.1 W (DC) General Characteristics Electrical Life at Rated Load 200,000 operations (where stated) Mechanical Life (Unpowered) 10,000,000 operations Operating Time 25 ms max. at 80% rated coil voltage 20 ms max. at 100% rated coil voltage Release Time DC: 20 ms max. AC: 35 ms max. Impulse Withstand Voltage Dielectric Strength 2.5 kV (1.2 / 50 s) Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 1600 V (rms) Between Contacts (AC) 1300 V (rms) Ambient Air Temperature Around the Device Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Vibration Resistance In Operation 3 gn at 35-150 Hz Not Operating 5 gn at 35-150 Hz In Operation 10 gn Not Operating 30 gn Shock Resistance 100,000 operations (general purpose load) Degree of Protection (Housing Only) IP40 Weight 37 g (1.31 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 6 Legacy General Purpose Relays Dimensions, Wiring Diagrams 792 Control Series DPDT 12 A; 4PDT 6 A and 3 A Dimensions, in. (mm) Clear Cover Dimension 0.83 (21.0) 1.1 (27.9) 0.24 (6.0) 1.4 (35.5) Full-Feature Cover Dimension 0.27 (7.0) 0.83 (21.0) 0.02 (0.5) 1.1 (27.9) 0.24 (6.0) 1.54 (39.1) Wiring Diagrams DPDT 4PDT 1 4 1 2 3 4 (12) (42) (12) (22) (32) (42) 5 8 5 6 7 8 (14) (44) (14) (24) (34) (44) 9 12 9 10 11 12 (11) (41) (11) (21) (31) (41) 13 14 13 14 (A1) (A2) (A1) (A2) NEMA (IEC) NEMA (IEC) 7 Legacy General Purpose Relays Description 792 Control Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories Description Function For Use with Relays Pkg. Min. Standard Part Number Socket DIN or panel mounting with elevator terminals 792XBX 10 70-782EL8-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-782D14-1 792XBX / 792XDX DIN or panel mounting with rising elevator box terminals 10 70-782E14-1 Socket DIN or panel mounting with elevator terminals 10 70-782EL14-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-461-1 Socket Solder terminals for chassis mounting 10 70-378-1 Socket Printed circuit terminals for PCB mounting 10 70-379-1 10 16-782C 10 16-782C1 Socket Adapter Direct DIN rail mounting Adapter Direct panel mounting 792XDX 792XBX / 792XDX Socket Accessories Description Function Metal Spring Clip For Use with Sockets Securing the relay in the socket Coil Voltage Pkg. Standard Min. Part Number -- 10 16-782SC -- 10 16-782PC-1 -- 10 16-782FT-1 70-782D14-1, Securing the relay in the socket or 70-782E14-1, ejecting the relay from the socket 70-782EL14-1, 70-782EL8-1 Small write-on tag Write-on tag for the 16-782PC-1 hold-down clip -- -- 10 16-700ST-1 Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets 70-782D14-1, 70-782E14-1, -- 70-782EL8-1, 70-782EL14-1 10 16-700DIN DIN Rail End Clip Holding the sockets firmly in place -- on a DIN rail -- 10 16-DCLIP-1 70-782EL8-1, 70-782EL14-1 -- 10 16-782CBJ-1 6-250 Vdc 10 70-BSMD-250 24 Vac/Vdc Plastic Hold-Down Clip Write-on Tag Write-on Tag Insulated Coil Bus Jumper System Wireless socket connection Small Socket Modules Protection Diode LED Indicator MOV Suppressor Protecting the external drive circuitry from inductive voltages Providing coil status at a glance Protection from damaging electrical spikes 70-782D14-1, 70-782E14-1, 70-782EL14-1, 70-782EL8-1 Note: Using an LED socket module can increase the coil power draw by up to 10%. 8 10 70-BSMLG-24 120 Vac/Vdc 10 70-BSMM-120 24 Vac/Vdc 70-BSMM-24 10 240 Vac/Vdc 10 70-BSMM-240 Legacy General Purpose Relays Description 781R Series SPDT 15 A Description The 781R Series plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. UL Listed when used with corresponding sockets 781R Clear Cover Contact Rating 15 A Feature Benefit 15 A max. switching current Ideal choice for automation control panels 14 mm width Slim design to save valuable space Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation 781R Full-Feature Cover Contact Configuration SPDT Standard Part Number Nominal Voltage Coil Resistance () Clear Cover Clear Cover with LED Full-Feature 12 Vac, 50/60 Hz 44 781XAXRC-12A 781XAXRCL-12A 781XAXRM4L-12A 24 Vac, 50/60 Hz 177 781XAXRC-24A 781XAXRCL-24A 781XAXRM4L-24A 48 Vac, 50/60 Hz 708 781XAXRC-48A 781XAXRCL-48A 781XAXRM4L-48A 120 Vac, 50/60 Hz 4,430 781XAXRC-120A 781XAXRCL-120A 781XAXRM4L-120A 240 Vac, 50/60 Hz 17,720 781XAXRC-240A 781XAXRCL-240A 781XAXRM4L-240A 12 Vdc 115 781XAXRC-12D 781XAXRCL-12D 781XAXRM4L-12D 24 Vdc 450 781XAXRC-24D 781XAXRCL-24D 781XAXRM4L-24D 48 Vdc 1,800 781XAXRC-48D 781XAXRCL-48D 781XAXRM4L-48D 110 Vdc 9,460 781XAXRC-110D 781XAXRCL-110D 781XAXRM4L-110D Part Number Explanation Series: 781 = 781R Series Relay XAXR Contact Configuration: XAXR = SPDT Coil Voltages: 12-240A = 12-240 Vac 12-110D = 12-110 Vdc Cover Options: C = Clear Cover CL = Clear Cover and LED M4L = Locking Push Button and LED For more information, contact customer service (1-847-441-2540). 9 Legacy General Purpose Relays Specifications 781R Series SPDT 15 A Specifications Part Number 781XAXR Contact Characteristics Terminal Style Blade Contact Material Silver Alloy Contact Configuration SPDT Carrying Current 15 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 28 Vdc Rated Switching Current at Voltage (Conforming to IEC AC-1 and DC-1) at 250 Vac N.O.: 15 A; N.C.: 7.5 A at 28 Vdc N.O.: 15 A; N.C.: 7.5 A Rated Switching Current at Voltage (Conforming to UL) Resistive 15 A at 277 Vac, 50/60 Hz, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Resistive 15 A at 150 Vac, 50/60 Hz, 100 k cycles 10 A at 277 Vdc, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Rated Switching Current at Voltage (Conforming to CSA) Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC/DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption Standard: 1.6 VA (AC); 1.1 W (DC) With LED: 1.9 VA (AC); 1.4 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life (Unpowered) 10,000,000 operations Operating Time (Response Time) Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 15 gn Degree of Protection (Housing Only) IP40 Weight 29 g (1.02 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 10 Dimensions, Wiring Diagram Legacy General Purpose Relays 781R Series SPDT 15 A Dimensions, in. (mm) Clear Cover Dimensions 0.55 (14.0) 1.37 (34.8) 0.02 (0.5) 1.07 (27.3) 0.02 (0.5) 0.28 (7.0) 0.55 (14.0) 0.21 (5.4) 1.57 (39.8) 0.02 (0.5) 0.26 (6.5) 1.07 (27.3) 0.02 (0.5) 0.19 (4.8) 0.28 (7.0) 0.24 (6.0) Full-Feature Cover Dimensions 0.08 (2.1) 0.17 (4.2) Wiring Diagram 1 (12) 5 (14) 9 (11) 13 (A1) 14 (A2) NEMA (IEC) 11 Legacy General Purpose Relays Description 781R Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories For Use with Relays Description Function Socket DIN or panel mounting with screw terminals and clamping plates Socket PCB mounting Adapter Direct DIN rail mounting Adapter Direct panel mounting 781XAXR Pkg. Min. Standard Part Number 10 70-781D5R-1A 10 70-781T-1 10 16-781C 10 16-781C1 Socket Accessories Description Metal Spring Clip Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Securing the relay in the socket 70-781D5R-1A, 70-781T-1 -- 10 16-781SC -- 10 16-781IDC -- 10 16-700DIN -- 10 16-DCLIP-1 6-250 Vdc 10 70-BSMD-250 24 Vac/Vdc 10 70-BSMLG-24 120 Vac/Vdc 10 70-BSMM-120 24 Vac/Vdc 10 70-BSMM-24 240 Vac/Vdc 10 70-BSMM-240 Plastic ID Hold-Down Clip Securing the relay in the socket and providing labeling Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets DIN Rail End Clip Holding the sockets firmly in place on a DIN rail 70-781D5R-1A -- Small Socket Modules Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator Providing coil status at a glance MOV Suppressor 70-781D5R-1A Protection from damaging electrical spikes Note: Using an LED socket module can increase the coil power draw by up to 10%. 12 Legacy General Purpose Relays Description 782 Power Series DPDT 15 A Description The 782 plug-in power relays offer clear or full-feature covers with multiple mounting options and accessories. UL Listed when used with corresponding sockets 782 Clear Cover Contact Rating 15 A Contact Configuration DPDT Feature Benefit 15 A switching current Ideal choice for automation control panels Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation 782 Full-Feature Cover Nominal Voltage Coil Resistance () Clear Cover Standard Part Number Clear Cover with LED PC Mount Full-Feature 6 Vac, 50/60 Hz 11 -- -- 782XBXCT-6A -- 12 Vac, 50/60 Hz 44 782XBXC-12A 782XBXCL-12A 782XBXCT-12A 782XBXM4L-12A 24 Vac, 50/60 Hz 177 782XBXC-24A 782XBXCL-24A 782XBXCT-24A 782XBXM4L-24A 48 Vac, 50/60 Hz 708 782XBXC-48A 782XBXCL-48A 782XBXCT-48A 782XBXM4L-48A 120 Vac, 50/60 Hz 4430 782XBXC-120A 782XBXCL-120A 782XBXCT-120A 782XBXM4L-120A 240 Vac, 50/60 Hz 17720 782XBXC-240A 782XBXCL-240A 782XBXCT-240A 782XBXM4L-240A 6 Vdc 40 -- -- 782XBXCT-6D -- 12 Vdc 160 782XBXC-12D 782XBXCL-12D 782XBXCT-12D 782XBXM4L-12D 24 Vdc 640 782XBXC-24D 782XBXCL-24D 782XBXCT-24D 782XBXM4L-24D 48 Vdc 2560 782XBXC-48D 782XBXCL-48D 782XBXCT-48D 782XBXM4L-48D 110 Vdc 13440 782XBXC-110D 782XBXCL-110D 782XBXCT-110D 782XBXM4L-110D Part Number Explanation Series: 782 = 782 Series Power Relay Contact Configuration: XBX = DPDT Coil Voltages: 6-240A = 6-240 Vac 6-110D = 6-110 Vdc Cover Options: C = Clear Cover CL = Clear Cover and LED CT = PC Termimals M4L = Locking Push Button and LED For more information, contact customer service (1-847-441-2540). 13 Legacy General Purpose Relays Specifications 782 Power Series DPDT 15 A Specifications Part Number 782XBXC / CL / M4L 782XBXCT Terminal Style Blade PC Terminals Contact Material Silver Alloy Contact Configuration DPDT Carrying Current 15 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 28 Vdc Contact Characteristics Rated Switching Current at Voltage (Conforming to IEC AC-1 and DC-1) at 250 Vac N.O.: 15 A; N.C.: 7.5 A at 28 Vdc N.O.: 15 A; N.C.: 7.5 A Rated Switching Current at Voltage (Conforming to UL) Resistive 15 A at 277 Vac, 50/60 Hz, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Resistive 15 A at 150 Vac, 50/60 Hz, 100 k cycles 10 A at 277 Vac, 50/60 Hz, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Rated Switching Current at Voltage (Conforming to CSA) Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption Standard: 1.1 VA (AC); 0.85 W (DC) With LED: 1.4 VA (AC); 1.15 W (DC) Standard: 1.1 VA (AC); 0.85 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life (Unpowered) 10,000,000 operations Operating Time (Response Time) Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 15 gn Degree of Protection (Housing Only) IP40 Weight 36 g (1.27 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 14 Dimensions, Wiring Diagrams Legacy General Purpose Relays 782 Power Series DPDT 15 A Dimensions, in. (mm) Clear Cover Dimensions 1.37 [34.8] 0.19 [4.7] 0.83 [21.0] 0.08 [2.0] 1.07 [27.3] 0.02 [0.5] 0.02 [0.5] 0.2 [5.0] 0.28 [7.0] PC Terminals Dimensions 0.83 [21.0] 0.32 [8.1] 1.54 [39.0] 0.19 [4.7] 0.28 [7.1] 1.07 [27.3] 0.02 [0.5] 0.39 [10.0] 0.23 [5.9] 0.28 [7.0] 0.18 [4.6] Full-Feature Cover Dimensions 0.08 [2.1] 0.56 [14.2] Wiring Diagram 1 (12) 4 (42) 5 (14) 8 (44) 9 (11) 12 (41) 13 (A1) 14 (A2) NEMA (IEC) 15 Legacy General Purpose Relays Description 782 Power Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories Pkg. Min. Standard Part Number DIN or panel mounting with screw terminals and clamping plates 10 70-782D8-1A DIN or panel mounting with screw terminals and clamping plates 10 70-459-1 Socket Quick Connect terminals for chassis mounting 10 70-401-1 Socket Printed circuit terminals for PCB mounting 10 70-402-1 Description Function Socket Socket For Use with Relays 782XBX Adapter Direct panel mounting 10 16-782C1 Adapter Direct DIN rail mounting 10 16-782C Socket Accessories Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Securing the relay in the socket 70-782D8-1A, 70-459-1, 70-401-1, 70-402-1 -- 10 16-1342 Plastic Hold-Down Clip Securing the relay in the socket, or ejecting the relay from the socket 70-782D8-1A -- 10 16-782PC-1 Write-on Tag Write-on tag for the 16-782PC-1 hold-down clip -- -- 10 16-700ST-1 Plastic ID Hold-Down Clip Securing the relay in the socket and providing labeling 70-782D8-1A, 70-459-1, 70-401-1, 70-402-1 -- 10 16-782IDC Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets -- 10 16-700DIN DIN Rail End Clip Holding the sockets firmly in place on a DIN rail -- 10 16-DCLIP-1 6-250 Vdc 10 70-BSMD-250 24 Vac/Vdc 10 70-BSMLG-24 120 Vac/Vdc 10 70-BSMM-120 24 Vac/Vdc 10 70-BSMM-24 240 Vac/Vdc 10 70-BSMM-240 Description Metal Spring Clip 70-782D8-1A, 70-459-1 Small Socket Modules Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator Providing coil status at a glance MOV Suppressor 70-782D8-1A Protection from damaging electrical spikes Note: Using an LED socket module can increase the coil power draw by up to 10%. 16 Legacy General Purpose Relays Description 783 Series 3PDT 15 A Description The 783 Series plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. UL Listed when used with corresponding sockets 783 Clear Cover Contact Rating 15 A Feature Benefit 15 A max. switching current Ideal choice for automation panels and controls Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button 3PDT contact configuration Simultaneous control of up to three separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation 783 Full-Feature Cover Contact Configuration 3PDT Standard Part Number Nominal Voltage Coil Resistance () Clear Cover Clear Cover with LED Full-Feature 12 Vac, 50/60 Hz 30 783XCXC-12A 783XCXCL-12A 783XCXM4L-12A 24 Vac, 50/60 Hz 110 783XCXC-24A 783XCXCL-24A 783XCXM4L-24A 48 Vac, 50/60 Hz 460 783XCXC-48A 783XCXCL-48A 783XCXM4L-48A 120 Vac, 50/60 Hz 2,880 783XCXC-120A 783XCXCL-120A 783XCXM4L-120A 240 Vac, 50/60 Hz 11,300 783XCXC-240A 783XCXCL-240A 783XCXM4L-240A 12 Vdc 80 783XCXC-12D 783XCXCL-12D 783XCXM4L-12D 24 Vdc 320 783XCXC-24D 783XCXCL-24D 783XCXM4L-24D 48 Vdc 1,280 783XCXC-48D 783XCXCL-48D 783XCXM4L-48D 110 Vdc 6,720 783XCXC-110D 783XCXCL-110D 783XCXM4L-110D Part Number Explanation Series: 783 = 783 Series Relay Contact Configuration: XCX = 3PDT Coil Voltages: 12-240A = 12-240 Vac 12-110D = 12-110 Vdc Cover Options: C = Clear Cover CL = Clear Cover and LED M4L = Locking Push Button and LED For more information, contact customer service (1-847-441-2540). 17 Legacy General Purpose Relays Specifications 783 Series 3PDT 15 A Specifications Part Number 783XCX Contact Characteristics Terminal Style Blade Contact Material Silver Alloy Contact Configuration 3PDT Carrying Current per Pole 15 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 28 Vdc Rated Switching Current-- Conforming to IEC AC-1 and DC-1 at 250 Vac N.O.: 15 A; N.C.: 7.5 A at 28 Vdc N.O.: 15 A; N.C.: 7.5 A Rated Switching Current-- Conforming to UL Resistive 15 A at 277 Vac, 50/60 Hz, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Resistive 15 A at 150 Vac, 50/60 Hz, 100 k cycles, 30 A max. total 10 A at 277 Vac, 50/60 Hz, 100 k cycles, 20 A max. total 15 A at 28 Vdc, 100 k cycles, 30 A max. total Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles, 2 hp max. total Pilot Duty B300 Rated Switching Current-- Conforming to CSA Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption Standard: 1.7 VA (AC); 1.5 W (DC) With LED: 2.05 VA (AC); 1.85 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life (Unpowered) 10,000,000 operations Operating Time Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 15 gn Degree of Protection (Housing Only) IP40 Weight 60 g (2.12 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 18 Legacy General Purpose Relays Dimensions, Wiring Diagrams 783 Series 3PDT 15 A Dimensions, in. (mm) Clear Cover Dimensions 1.07 [27.3] 0.02 [0.5] 0.28 [7.0] 0.28 [7.1] 0.18 [4.6] 1.37 [34.8] 0.19 [4.7] 1.2 [30.6] 0.39 [10.0] 0.23 [5.9] 0.39 [10.0] Full-Feature Cover Dimensions 0.27 [6.8] 1.2 [30.6] 1.54 [39.0] 0.39 [10.0] 0.79 [20.0] 0.19 [4.7] 1.07 [27.3] 0.02 [0.5] 0.28 [7.0] Wiring Diagram 1 (12) 2 (22) 4 (42) 5 (14) 6 (24) 8 (44) 9 (11) 10 (21) 12 (41) 13 (A1) 14 (A2) NEMA (IEC) 19 Legacy General Purpose Relays Description, Specifications 783 Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories For Use with Relays Description Function Socket DIN or panel mounting (finger-safe according to IP20), with screw terminals and clamping plates Adapter Adapter Direct DIN rail mounting Direct panel mounting 783XCX Pkg. Min. Standard Part Number 10 70-783D11-1A 10 16-783C 10 16-783C1 Socket Accessories Description Coil Voltage Pkg. Min. Standard Part Number -- 10 16-783SC -- 10 16-783IDC -- 10 16-700DIN -- 10 16-DCLIP-1 24 Vac/Vdc 10 70-ASMM-24 250 Vdc 10 70-ASMD-250 Providing coil status at a glance 110/240 Vac/Vdc 10 70-ASMLG-110/240 Snubbing back the EMF of the relay coil 110/240 Vac 10 70-ASMR-110/240 Function Metal Spring Clip Securing the relay in the socket Plastic ID Hold-Down Clip Securing the relay in the socket and providing labeling Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets DIN Rail End Clip Holding the sockets firmly in place on a DIN rail For Use with Sockets 70-783D11-1A -- Large Socket Module MOV Suppressor Protection from damaging electrical spikes Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator RC Suppressor 70-783D11-1A Note: Using an LED or RC socket module can increase the coil power draw by up to 10%. 20 Legacy General Purpose Relays Description 784 Series 4PDT 15 A Description The 784 Series plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. UL Listed when used with corresponding sockets 784 Clear Cover Contact Rating 15 A 784 Full-Feature Cover Contact Configuration 3PDT Feature Benefit 15 A max. switching current Ideal choice for automation panels and controls Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button 4PDT contact configuration Simultaneous control of up to 4 separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation Standard Part Number Nominal Voltage Coil Resistance () Clear Cover Clear Cover with LED Full-Feature 12 Vac, 50/60 Hz 20 784XDXC-12A 784XDXCL-12A 784XDXM4L-12A 24 Vac, 50/60 Hz 80 784XDXC-24A 784XDXCL-24A 784XDXM4L-24A 48 Vac, 50/60 Hz 310 784XDXC-48A 784XDXCL-48A 784XDXM4L-48A 120 Vac, 50/60 Hz 2100 784XDXC-120A 784XDXCL-120A 784XDXM4L-120A 240 Vac, 50/60 Hz 8000 784XDXC-240A 784XDXCL-240A 784XDXM4L-240A 12 Vdc 76 784XDXC-12D 784XDXCL-12D 784XDXM4L-12D 24 Vdc 303 784XDXC-24D 784XDXCL-24D 784XDXM4L-24D 48 Vdc 1210 784XDXC-48D 784XDXCL-48D 784XDXM4L-48D 110 Vdc 6370 784XDXC-110D 784XDXCL-110D 784XDXM4L-110D Part Number Explanation Series: 784 = 784 Series Relay Contact Configuration: XDX = 4PDT Coil Voltages: 12-240A = 12-240 Vac 12-110D = 12-110 Vdc Cover Options: C = Clear Cover CL = Clear Cover and LED M4L = Locking Push Button and LED For more information, contact Customer Service (1-847-441-2540). 21 Legacy General Purpose Relays Specifications 784 Series 4PDT 15 A Specifications Part Number 784XDX Contact Characteristics Terminal Style Blade Contact Material Silver Alloy Contact Configuration 4PDT Carrying Current per Pole 15 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 28 Vdc Rated Switching Current (Conforming to IEC AC-1 and DC-1) at 250 Vac N.O.: 15 A; N.C.: 7.5 A at 28 Vdc N.O.: 15 A; N.C.: 7.5 A Rated Switching Current (Conforming to UL) Resistive 15 A at 277 Vac, 50/60 Hz, 100 k cycles 15 A at 28 Vdc, 100 k cycles Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles Pilot Duty B300 Resistive 15 A at 150 Vac, 50/60 Hz, 100 k cycles, 30 A max. total 10 A at 277 Vac, 50/60 Hz, 100 k cycles, 20 A max. total 15 A at 28 Vdc, 100 k cycles, 30 A max. total Motor 1/2 hp at 120 Vac, 1 k cycles 1 hp at 277 Vac, 1 k cycles, 2 hp max. total Pilot Duty B300 Rated Switching Current (Conforming to CSA) Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption Standard: 2.5 VA (AC); 1.6 W (DC) With LED: 2.85 VA (AC); 1.95 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life (Unpowered) 10,000,000 operations Operating Time Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 2000 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 15 gn Degree of Protection (Housing Only) IP40 Weight 80 g (2.82 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 22 Legacy General Purpose Relays Dimensions, Wiring Diagrams 784 Series 4PDT 15 A Dimensions, in. (mm) Clear Cover Dimensions 1.07 [27.3] 0.02 [0.5] 0.28 [7.0] 0.28 [7.1] Full-Feature Cover Dimensions 0.23 [5.9] 0.39 [10.0] 0.18 [4.6] 1.37 [34.8] 1.6 [40.6] 0.19 [4.7] 0.39 [10.0] 0.39 [10.0] 1.07 [27.3] 0.02 [0.5] 0.28 [7.0] 1.54 [39.0] 0.19 [4.7] 1.18 [30.0] 0.27 [6.7] 1.6 [40.6] 0.39 [10.0] Wiring Diagram 1 (12) 2 (22) 3 (32) 4 (42) 5 (14) 6 (24) 7 (34) 8 (44) 9 (11) 10 (21) 11 (31) 12 (41) 13 (A1) 14 (A2) NEMA (IEC) 23 Legacy General Purpose Relays Description 784 Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories For Use with Relays Description Function Socket DIN or panel mounting (finger-safe according to IP20) with screw terminals and clamping plates Adapter DIN rail adapter Adapter Flange mount adapter 784XDX Pkg. Min. Standard Part Number 10 70-784D14-1 10 16-784C 10 16-784C1 Socket Accessories Description Function Metal Spring Clip Securing the relay in the socket Plastic ID Hold-Down Clip Securing the relay in the socket and providing labeling Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of the sockets DIN Rail End Clip Holding the sockets firmly in place on a DIN rail For Use with Socket 70-784D14-1 -- Coil Voltage Pkg. Min. Standard Part Number -- 10 16-784SC -- 10 16-784IDC -- 10 16-700DIN -- 10 16-DCLIP-1 24 Vac/Vdc 10 70-ASMM-24 250 Vdc 10 70-ASMD-250 Large Socket Module MOV Suppressor Protection from damaging electrical spikes Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator Providing coil status at a glance 110/240 Vac/Vdc 10 70-ASMLG-110/240 Snubbing back the EMF of the relay coil 110/240 Vac 10 70-ASMR-110/240 RC Suppressor 70-784D14-1 Note: Using an LED or an RC socket module can increase the coil power draw by up to 10%. 24 Legacy General Purpose Relays Description 750R Series DPDT and 3DPT, 10 A Description UL Listed when used with corresponding sockets 750R Clear Cover 750R Full-Feature Cover The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. Feature Benefit Octal style mounting Robust and historically proven mounting platform that provides excellent structural support 10 A max. switching current Ideal choice for automation panels and controls Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button DPDT and 3PDT contact configurations Simultaneous control of separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation Standard Part Number Contact Rating Contact Configuration DPDT 10 A 3PDT Nominal Voltage Coil Resistance () Clear Cover Clear Cover with LED Full-Feature 6 Vac, 50/60 Hz 3.9 750XBXRC-6A -- -- 12 Vac, 50/60 Hz 16.9 750XBXRC-12A 750XBXRCL-12A 750XBXRM4L-12A 24 Vac, 50/60 Hz 72 750XBXRC-24A 750XBXRCL-24A 750XBXRM4L-24A 48 Vac, 50/60 Hz 290 -- -- 750XBXRM4L-48A 120 Vac, 50/60 Hz 1700 750XBXRC-120A 750XBXRCL-120A 750XBXRM4L-120A 240 Vac, 50/60 Hz 6800 750XBXRC-240A 750XBXRCL-240A 750XBXRM4L-240A 6 Vdc 3.9 750XBXRC-6D -- 750XBXRM4L-6D 12 Vdc 120 750XBXRC-12D 750XBXRCL-12D 750XBXRM4L-12D 24 Vdc 470 750XBXRC-24D 750XBXRCL-24D 750XBXRM4L-24D 48 Vdc 1800 750XBXRC-48D 750XBXRCL-48D 750XBXRM4L-48D 110 Vdc 7300 750XBXRC-110D 750XBXRCL-110D 750XBXRM4L-110D 24 Vac, 50/60 Hz 72 750XCXRC-24A 750XCXRCL-24A 750XCXRM4L-24A 48 Vac, 50/60 Hz 290 -- -- 750XCXRM4L-48A 120 Vac, 50/60 Hz 1700 750XCXRC-120A 750XCXRCL-120A 750XCXRM4L-120A 240 Vac, 50/60 Hz 6800 750XCXRC-240A 750XCXRCL-240A 750XCXRM4L-240A 12 Vdc 120 750XCXRC-12D 750XCXRCL-12D 750XCXRM4L-12D 24 Vdc 470 750XCXRC-24D 750XCXRCL-24D 750XCXRM4L-24D 48 Vdc 1800 750XCXRC-48D 750XCXRCL-48D 750XCXRM4L-48D 110 Vdc 7300 750XCXRC-110D 750XCXRCL-110D 750XCXRM4L-110D Part Number Explanation Series: 750 = 750R Series Relay Contact Configuration: XBXR = DPDT XCXR = 3PDT Coil Voltages: 6-240A = 6-240 Vac Cover Options: 6-110D = 6-110 Vdc C = Clear Cover CL = Clear Cover and LED For more information, contact M4L = Locking Push Button Customer Service (1-847-441-2540). and LED 25 Specifications Legacy General Purpose Relays 750R Series DPDT and 3DPT, 10 A Specifications Part Number 750XBXR 750XCXR Terminal Style Octal Octal Contact Material Silver Alloy Silver Alloy Contact Configuration DPDT 3PDT Carrying Current 10 A 10 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc Rated Switching Current (Conforming to IEC AC-1 and DC-1) N.O.: 10 A at 250 Vac / 28 Vdc N.C.: 5 A at 250 Vac / 28 Vdc N.O.: 10 A at 250 Vac / 28 Vdc N.C.: 5 A at 250 Vac / 28 Vdc Rated Switching Current (Conforming to UL) Resistive 10 A at 277 Vac, 50/60 Hz, 200 k cycles 10 A at 30 Vdc, 200 k cycles 10 A at 277 Vac, 50/60 Hz, 200 k cycles 10 A at 30 Vdc, 200 k cycles Motor 1/3 hp at 120 Vac, 6 k cycles 1 hp at 277 Vac, 6 k cycles 1/3 hp at 120 Vac, 6 k cycles 1 hp at 277 Vac, 6 k cycles Pilot Duty B300, 6 k cycles B300, 6 k cycles 10 mA at 17 Vdc 10 mA at 17 Vdc Contact Characteristics Minimum Switching Requirement Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption 3 VA (AC); 1.4 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life 5,000,000 operations Operating Time Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 2500 V (rms) Between Poles (AC) 2000 V (rms) Between Contacts (AC) 1500 V (rms) Storage -40 to +85 C (-40 to +185F) Operation -40 to +55 C (-40 to +131F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 10 gn Degree of Protection (Housing Only) IP40 Weight 83 g (2.93 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 26 Legacy General Purpose Relays Dimensions, Wiring Diagram 750R Series DPDT and 3DPT, 10 A Dimensions, in. (mm) Clear Cover Dimensions 1.4 (35.7) 1.38 (35) 2.09 (53) Full-Feature Cover Dimensions 1.4 (35.7) 0.24 (6.1) 2.2 (56) 1.38 (35) Wiring Diagrams DPDT (12) 4 3PDT (22) 5 (12) 4 (24) 6 (14) 3 (14) (A1) (A2) 2 7 1 (11) (21) 6 (22) 5 NEMA (IEC) (32) 8 9 3 (A1) 2 8 (31) (24) 7 10 (11) 1 11 (34) (A2) (31) 27 Legacy General Purpose Relays Description 750R Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories Description Function For Use Pkg. with Relays Min. Standard Part Number Socket DIN or panel mounting, module compatible 10 70-750E8-1 Socket DIN or panel mounting with elevator terminals, module compatible 10 70-750EL8-1 Socket DIN or panel mounting, module compatible 10 70-750DL8-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-464-1 Socket Panel mounting with screw terminals and clamping plates 10 70-169-1 Socket DIN or panel mounting with elevator terminals, module compatible 10 70-750E11-1 Socket DIN or panel mounting with elevator terminals 10 70-750EL11-1 Socket DIN or panel mounting, module compatible 10 70-750DL11-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-465-1 Panel mounting with screw terminals and clamping plates 10 70-170-1 Socket 750XBXR 750XCXR Socket Accessories Description Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Metal Spring Clip Securing the relay in the socket 70-750EL8-1, 70-750E8-1, 70-750E11-1, 70-464-1 -- 10 16-1351 Metal Spring Clip Securing the relay in the socket 70-750E8-1, 70-750DL8-1, 70-750E11-1, 70-464-1 -- 10 16-1344 Metal Spring Clip Securing the relay in the socket 70-750DL8-1 -- 10 16-1332 70-750E8-1, 70-750EL8-1, 70-750DL8-1, 70-750E11-1, 70-750EL11, 70-750DL11-1 -- 10 16-750/788FT-1 -- 10 16-750/788CBJ-1 Plastic ID Tag Write-on plastic labels Insulated Coil Bus Jumper System Wireless socket connection Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets 70-750EL8-1, 70-750E8-1, 70-750DL8-1, 70-750E11-1, 70-464-1, 70-465-1 -- 10 16-700DIN DIN Rail End Clip Plastic end clip with locking screw -- -- 10 16-DCLIP-1 24 Vac/Vdc 10 70-ASMM-24 250 Vdc 10 70-ASMD-250 110/240 Vac/Vdc 10 70-ASMLG-110/240 110/240 Vac 10 70-ASMR-110/240 Large Socket Modules MOV Suppressor Protection from damaging electrical spikes Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator Providing coil status at a glance RC Suppressor Snubbing back the EMF of the relay coil 70-750E8-1, 70-750EL8-1, 70-750DL8-1, 70-750E11-1, 70-750EL11-1, 70-750DL11-1 Note: Using an LED or RC socket module can increase the coil power draw by up to 10%. 28 Legacy General Purpose Relays Description 788R Series DPDT and 3PDT 10 A Description The 788R Series square base, plug-in relays offer clear, full-feature, top flange, and side flange covers as well as optional sockets and accessories. UL Listed when used with corresponding sockets 7885 Clear Cover 7885 Full-Feature Cover Feature Benefit 10 A max. switching current Ideal choice for automation panels and controls Clear or full-feature cover options Full-feature covers include an LED indicator and a locking test button DPDT and 3PDT contact configurations Simultaneous control of separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Mechanical flag indicator (standard) Display of the relay status during testing or operation Standard Part Number Contact Rating Contact Configuration DPDT 10 A 3PDT Nominal Voltage Coil Resistance () Clear Cover Clear Cover with LED Flange Mount Full-Feature 24 Vac, 50/60 Hz 48 Vac, 50/60 Hz 72 788XBXRC-24A 788XBXRCL-24A 788XBXRC1-24A 788XBXRM4L-24A 290 -- -- -- 788XBXRM4L-48A 120 Vac, 50/60 Hz 1700 788XBXRC-120A 788XBXRCL-120A 788XBXRC1-120A 788XBXRM4L-120A 240 Vac, 50/60 Hz 6800 788XBXRC-240A 788XBXRCL-240A 788XBXRC1-240A 788XBXRM4L-240A 12 Vdc 120 788XBXRC-12D 788XBXRCL-12D 788XBXRC1-12D 788XBXRM4L-12D 24 Vdc 470 788XBXRC-24D 788XBXRCL-24D 788XBXRC1-24D 788XBXRM4L-24D 48 Vdc 1800 788XBXRC-48D 788XBXRCL-48D 788XBXRC1-48D 788XBXRM4L-48D 110 Vdc 7300 788XBXRC-110D 788XBXRCL-110D 788XBXRC1-110D 788XBXRM4L-110D 12 Vac, 50/60 Hz 16.9 788XCXRC-12A -- -- -- 24 Vac, 50/60 Hz 72 788XCXRC-24A 788XCXRCL-24A 788XCXRC1-24A 788XCXRM4L-24A 48 Vac, 50/60 Hz 290 -- -- -- 788XCXRM4L-48A 120 Vac, 50/60 Hz 1700 788XCXRC-120A 788XCXRCL-120A 788XCXRC1-120A 788XCXRM4L-120A 240 Vac, 50/60 Hz 6800 788XCXRC-240A 788XCXRCL-240A 788XCXRC1-240A 788XCXRM4L-240A 12 Vdc 120 788XCXRC-12D 788XCXRCL-12D 788XCXRC1-12D 788XCXRM4L-12D 24 Vdc 470 788XCXRC-24D 788XCXRCL-24D 788XCXRC1-24D 788XCXRM4L-24D 48 Vdc 1800 788XCXRC-48D 788XCXRCL-48D 788XCXRC1-48D 788XCXRM4L-48D 110 Vdc 7300 788XCXRC-110D 788XCXRCL-110D 788XCXRC1-110D 788XCXRM4L-110D Note: Magnetic blowout versions are also available with an added contact rating of 3 A at 150 Vdc. Refer to the Part Number Explanation shown below. Part Number Explanation Series: 788 = 788R Series Relay Contact Configuration: XBXR = DPDT XCXR = 3PDT Coil Voltages: 12-240A = 12-240 Vac Cover Options: 12-110D = 12-110 Vdc C = Clear Cover DC Switching: CL = Clear Cover and LED Blank = None C1 = Flange Cover 69 = Magnetic M4L = Locking Push Button and LED Blowout For more information, contact (Clear Cover only) Customer Service (1-847-441-2540). 29 Legacy General Purpose Relays Specifications 788R Series DPDT and 3PDT 10 A Specifications Part Number 788XBXR 788XCXR Terminal Style Blade Blade Contact Material Silver Alloy Silver Alloy Contact Configuration DPDT 3PDT Carrying Current 10 A 10 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc Rated Switching Current (Conforming to IEC AC-1 and DC-1) N.O.: 10 A at 250 Vac / 28 Vdc N.C.: 5 A at 250 Vac / 28 Vdc N.O.: 10 A at 250 Vac / 28 Vdc N.C.: 5 A at 250 Vac / 28 Vdc Resistive 10 A at 277 Vac, 50/60 Hz, 200 k cycles 10 A at 30 Vdc, 200 k cycles 10 A at 277 Vac, 50/60 Hz, 200 k cycles 10 A at 30 Vdc, 200 k cycles Motor 1/3 hp at 120 Vac, 6 k cycles 1 hp at 277 Vac, 6 k cycles 1/3 hp at 120 Vac, 6 k cycles 1 hp at 277 Vac, 6 k cycles Pilot Duty B300, 6 k cycles B300, 6 k cycles Rated Current with Magnetic Blowout (Code 69) UL: 3 A at 150 Vdc (DPDT only), 6 k cycles UL: 3 A at 150 Vdc (DPDT only), 6 k cycles Minimum Switching Requirement 10 mA at 17 Vdc 10 mA at 17 Vdc Maximum Operating Voltage 110% (AC/DC) 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) 15% (AC); 10% (DC) Average Consumption 3 VA (AC); 1.4 W (DC) 3 VA (AC); 1.4 W (DC) Electrical Life at Rated Load 100,000 operations 100,000 operations Mechanical Life (Unpowered) 5,000,000 operations 5,000,000 operations Operating Time 20 ms 20 ms Between Coil and Contact (AC) 2500 V (rms) 2500 V (rms) Between Poles (AC) 2000 V (rms) 2000 V (rms) Between Open Contacts (AC) 1500 V (rms) 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Vibration Resistance--In Operation 1 mm (10-35 Hz) and 3 gn (35-150 Hz) 1 mm (10-35 Hz) and 3 gn (35-150 Hz) Shock Resistance 10 gn 10 gn Degree of Protection (Housing Only) IP40 IP40 Weight 83 g (2.93 oz) 83 g (2.93 oz) Agency Approvals UL with socket, UR (E164862), CE, CSA (LR44087), RoHS UL with socket, UR (E164862), CE, CSA (LR44087), RoHS Contact Characteristics Rated Switching Current (Conforming to UL) Coil Characteristics General Characteristics Dielectric Strength Ambient Air Temperature Around the Device Note: Actual product performance may vary depending on the application and environmental conditions. 30 Legacy General Purpose Relays Dimensions, Wiring Diagrams 788R Series DPDT and 3PDT 10 A Dimensions, in. (mm) Clear Cover Dimensions 1.4 (35.7) 1.97 (50) 1.38 (35) Full-Feature Cover Dimensions 1.4 (35.7) 0.24 (6.1) 1.38 (35) 2.09 (53) Side Flange Cover Dimensions 2.77 (70.3) 1.9 (48.2) 2.37 (60.3) 1.4 (35.7) 0.04 (1.0) 1.38 (35) Wiring Diagrams SPDT DPDT 2 (32) 3PDT 1 3 1 2 3 (12) (22) (12) (32) (22) 5 4 6 4 5 6 (34) (14) (24) (14) (34) (24) 7 9 7 8 9 (31) (21) 7 (11) (11) (21) (11) A B A B A B (A1) (A2) (A1) (A2) (A1) (A2) NEMA (IEC) 31 Legacy General Purpose Relays Description 788R Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories For Use with Relays Description Function Socket DIN mounting with elevator terminals Socket DIN or panel mounting with screw terminals and clamping plates 788XBXR/ XCXR Pkg. Min. Standard Part Number 10 70-788EL11-1 10 70-463-1 0.187 in. Quick Connect terminals with mounting tabs 10 70-124-2 Socket Printed circuit terminals--with mounting tabs 10 70-178-1 Socket Printed circuit terminals--without mounting tabs 10 70-178-2 Socket Socket Accessories Description Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Metal Spring Clip Securing the relay in the socket 70-788EL11-1, 70-463-1, 70-124-1, 70-178-1, 70-178-2 -- 10 16-1351 Metal Spring Clip Securing the relay in the socket 70-463-1 -- 10 16-1344 -- 10 16-750/788CBJ-1 -- 10 16-750/788FT-1 Insulated Coil Bus Jumper System Wireless socket connection Plastic ID Tag Write-on plastic labels 70-788EL11-1 Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets 70-788EL11-1, 70-463-1 -- 10 16-700DIN DIN Rail End Clip Holding the sockets firmly in place on a DIN rail -- -- 10 16-DCLIP-1 24 Vac/Vdc 10 70-ASMM-24 250 Vdc 10 70-ASMD-250 Providing coil status at a glance 110/240 Vac/Vdc 10 70-ASMLG-110/240 Snubbing back the EMF of the relay coil 110/240 Vac 10 70-ASMR-110/240 Large Socket Module MOV Suppressor Protection from damaging electrical spikes Protection Diode Protecting the external drive circuitry from inductive voltages LED Indicator RC Suppressor 70-788EL11-1 Note: Using an LED or RC socket module can increase the coil power draw by up to 10%. 32 Legacy General Purpose Relays Description 782H Hazardous Location Series 4PDT 3 A and 5 A Description The hermetically sealed 782H Series relays comply with UL Class I Division 2 requirements for use in hazardous locations. UL Listed when used with corresponding sockets 782H Hazardous Location Relay Contact Rating 3A Contact Configuration 4PDT 5A 4PDT Feature Benefit Hermetically sealed Compliance with UL Class I Division 2 for Hazardous Locations Groups A, B, C, and D; sealed for wash down conditions 3 A / 5 A max. switching current Ideal choice for automation and control applications 4PDT contact configuration Simultaneous control of up to 4 separate circuits Screw-mounting options Direct mounting Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Gold-flashed contacts Reduced contact oxidation and increased shelf life Nominal Voltage Coil Resistance () Standard Part Number 120 Vac, 50/60 Hz 3,900 782XDXH10-120A 12 Vdc 160 782XDXH10-12D 24 Vdc 650 782XDXH10-24D 110 Vdc 11,000 782XDXH10-110D 120 Vac, 50/60 Hz 3,900 782XDXH21-120A 12 Vdc 160 782XDXH21-12D 24 Vdc 650 782XDXH21-24D Part Number Explanation Series: 782 = 782H Series Hazardous Location Relay Contact Configuration: XDXH = 4PDT, Hermetic Contact Code: 10 = 3 A Fine Silver, Gold Diffused 21 = 5 A Silver Alloy Coil Voltages: 24-240A = 24-240 Vac 12-110D = 12-110 Vdc For more information, contact Customer Service (1-847-441-2540). 33 Legacy General Purpose Relays Specifications 782H Hazardous Location Series 4PDT 3 A and 5 A Specifications Part Number 782XDXH21 782XDXH10 Contact Characteristics Terminal Style Blade Blade Contact Material Silver Alloy Fine Silver Load Type Standard Low Level Contact Configuration 4PDT 4PDT Carrying Current 5A 3A Maximum Switching Voltage 300 V 300 V Rated Switching Current (Conforming to IEC AC-1) 5 A at 240 Vac (N.O. or N.C. Only) 3 A at 240 Vac (N.O. or N.C. Only) Rated Switching Current (Conforming to UL and ANSI/ISA 12.12.01) Resistive 5 A at 120 Vac, 50/60 Hz, 100 k cycles 5 A at 240 Vac, 50/60 Hz, 100 k cycles 5 A at 30 Vdc, 100 k cycles 3 A at 120 Vac, 50/60 Hz, 100 k cycles 3 A at 240 Vac, 50/60 Hz, 100 k cycles 3 A at 30 Vdc, 100 k cycles Motor -- 1/10 hp at 120 Vac 1/10 hp at 240 Vac 100 mA at 5 Vdc 10 mA at 5 Vdc Minimum Switching Requirement Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 80% (AC); 75% (DC) Drop-out Voltage Threshold 30% (AC); 10% (DC) Average Consumption 1.2 VA (AC); 0.9 W (DC) General Characteristics Electrical Life at Rated Load 100,000 operations Mechanical Life (Unpowered) 10,000,000 operations Operating Time Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact (AC) 1600 V (rms) Between Poles (AC) 1600 V (rms) Storage -60 to +85 C (-76 to +185 F) Operation -45 to +70 C (-49 to +158 F) Temperature Code for Hazardous Locations T5: AC coil +40 C (+40 F), DC coil +70 C (+158 F) Vibration Resistance--In Operation 6 gn at 10-55 Hz Shock Resistance 10 gn Degree of Protection Hermetically sealed Weight 45 g (1.59 oz) Agency Approvals UL with socket, UR (E209950), CE, CSA (LR40787), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 34 Legacy General Purpose Relays Dimensions, Wiring Diagram 782H Hazardous Location Series 4PDT 3 A and 5 A Dimensions, in. (mm) 782H 0.25 (6.35) 0.91 (23.1) 0.02 (0.508) 1.16 (29.36) 0.312 (7.92) long, #3-48 thread 1.28 (32.54) Wiring Diagrams 4PDT 1 2 3 4 (12) (22) (32) (42) 5 6 7 8 (14) (24) (34) (44) 9 10 11 12 (11) (21) (31) (41) 13 14 (A1) (A2) NEMA (IEC) 35 Legacy General Purpose Relays Description 782H Hazardous Location Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories Pkg. Min. Standard Part Number DIN or panel mounting with screw terminals and clamping plates 10 70-782D14-1 DIN or panel mounting with elevator terminals 10 70-782EL14-1 Socket DIN or panel mounting with rising elevator box terminals 10 70-782E14-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-461-1 Socket Solder terminals for chassis mount 10 70-378-1 Socket Printed circuit terminals for PCB mount 10 70-379-1 Description Function Socket Socket For Use with Relays 782XDXH Socket Accessories Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Securing the relay in the socket 70-782D14-1, 70-782E14-1, 70-782EL14-1, 70-461-1, 70-378-1, 70-379-1 -- 10 16-1342 Write-on plastic labels 70-782E14-1, 70-782EL14-1 -- 10 16-782FT-1 Insulated Coil Bus Jumper System Wireless socket connection 70-782EL14-1 -- 10 16-782CBJ-1 Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets 70-782D14-1, 70-782EL14-1, 70-782E14-1 -- 10 16-700DIN DIN Rail End Clip Holding the sockets firmly in place on a DIN rail -- -- 10 16-DCLIP-1 Description Metal Spring Clip Plastic ID Tag 36 Legacy General Purpose Relays Description 750H Hazardous Location Series DPDT, 3PDT 12 A Description UL Listed when used with corresponding sockets 750H Hazardous Location Relay Contact Rating Contact Configuration DPDT 12 A 3PDT The hermetically sealed 750H Series relays comply with UL Class I Division 2 requirements for use in hazardous locations. Feature Benefit Hermetically sealed Compliance with UL Class I Division 2 for Hazardous Locations Groups A, B, C, and D; sealed for wash down conditions Octal style mounting Robust and historically proven mounting platform that provides excellent structural support 12 A max. switching current Ideal choice for automation and control applications DPDT and 3PDT contact configuration Simultaneous control of separate circuits Socket-mounting option Simplified installation and maintenance; use of protection modules, hold-down clips, and other accessories Nominal Voltage Coil Resistance () Standard Part Number 12 Vac, 50/60 Hz 18 750XBXH-12A 24 Vac, 50/60 Hz 72 750XBXH-24A 120 Vac, 50/60 Hz 1700 750XBXH-120A 240 Vac, 50/60 Hz 7200 750XBXH-240A 12 Vdc 120 750XBXH-12D 24 Vdc 470 750XBXH-24D 110 Vdc 10,000 750XBXH-110D 12 Vac, 50/60 Hz 18 750XCXH-12A 24 Vac, 50/60 Hz 72 750XCXH-24A 120 Vac, 50/60 Hz 1700 750XCXH-120A 240 Vac, 50/60 Hz 7200 750XCXH-240A 12 Vdc 120 750XCXH-12D 24 Vdc 470 750XCXH-24D 110 Vdc 10,000 750XCXH-110D Part Number Explanation Series: 750 = 750H Hazardous Location Series Relay Contact Configuration: XBXH = DPDT, Hermetic XCXH = 3PDT, Hermetic Coil Voltages: 12-240A = 12-240 Vac 12-110D = 12-110 Vdc For more information, contact Customer Service (847-441-2540). 37 Legacy General Purpose Relays Specifications 750H Hazardous Location Series DPDT, 3PDT 12 A Specifications (UL 508) Part Number 750XBXH 750XCXH Contact Characteristics Terminal Style Octal Contact Material Silver Alloy Load Type Standard Contact Configuration DPDT Carrying Current 12 A Maximum Switching Voltage Rated Switching Current (Conforming to UL and ANSI/ISA 12.12.01) 3PDT 300 V Resistive 12 A at 120 Vac, 50/60 Hz, 100,000 cycles 12 A at 240 Vac, 50/60 Hz, 100,000 cycles 12 A at 28 Vdc, 100,000 cycles Motor 1/2 hp at 240 Vac, 50/60 Hz , 100,000 cycles 1/3 hp at 120 Vac, 50/60 Hz , 100,000 cycles Pilot Duty B300 -- 100,000 cycles Minimum Switching Requirement 100 mA at 5 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC/DC) Maximum Pickup Voltage 85% (AC); 80% (DC) Drop-out Voltage Threshold 15% (AC); 10% (DC) Average Consumption 2.75 VA at 60 Hz (AC); 1.2 W (DC) General Characteristics Electrical Life (at Rated Load) 100,000 operations Mechanical Life (No Load) 10,000,000 operations Maximum Operating Time Dielectric Strength Ambient Air Temperature Around the Device 20 ms Between Coil and Contact 1600 V (rms) Between Poles 1600 V (rms) Between Open Contacts 1500 V (rms) Storage -40 to +85 C (-40 to +185 F) Operation -40 to +55 C (-40 to +131 F) Temperature Code for Hazardous Locations DC: T5, Max. Ambient Temperature +70 C AC: T4A, Max. Ambient Temperature +40 C Vibration Resistance--In Operation 3 gn at 35-150 Hz Shock Resistance 10 gn (11 ms) Degree of Protection Hermetically sealed Weight 130 g (4.59 oz) Agency Approvals UL with socket, UR (E209950), CSA (LR40787), RoHS Note: Actual product performance may vary depending on the application and environmental conditions. 38 Legacy General Purpose Relays Dimensions, Wiring Diagrams 750H Hazardous Location Series DPDT, 3PDT 12 A Dimensions, in. (mm) 750H 1.62 max. (41.2) 1.44 max. (36.5) 2.1 (52.5) Wiring Diagrams DPDT (12) 4 (14) 3PDT (22) 5 (12) 4 (24) 6 3 (14) (A1) 2 (11) 7 1 (A2) (22) 5 (21) 6 (24) 7 3 9 (A1) 2 8 (21) NEMA (IEC) (32) 8 10 (11) 1 11 (34) (A2) (31) 39 Legacy General Purpose Relays Description 750H Hazardous Location Series Accessories Description Optional sockets offer customizable solutions including protection modules, holddown clips, and ID tags. Sockets are finger-safe according to IP20, and compatible with DIN rail or panel mounting. Relay Accessories For Use with Relays Pkg. Min. Standard Part Number 10 70-750DL8-1 10 70-750E8-1 DIN or panel mounting with screw terminals and clamping plates 10 70-464-1 Panel mounting with screw terminals and clamping plates 10 70-169-1 Socket DIN or panel mounting 10 70-750DL11-1 Socket DIN or panel mounting with elevator terminals 10 70-750E11-1 Socket DIN or panel mounting with screw terminals and clamping plates 10 70-465-1 Socket Panel mounting with screw terminals and clamping plates 10 70-170-1 Description Function Socket DIN or panel mounting with screw terminals Socket DIN or panel mounting with elevator terminals, module compatible Socket Socket 750XBXH 750XCXH Socket Accessories Function For Use with Sockets Coil Voltage Pkg. Min. Standard Part Number Securing the relay in the socket 70-750DL8-1, 70-750E8-1, 70-464-1, 70-750E11-1, 70-750DL11-1, 70-465-1 -- 10 16-1351 Write-on plastic labels 70-750E8-1, 70-750E11-1 -- 10 16-750/788FT-1 Insulated Coil Bus Jumper System Wireless socket connection 70-750DL8-1, 70-750DL11-1 -- 10 16-750/788CBJ-1 Extruded Aluminum DIN Rail, 1 m (39.37 in.) Quick installation and removal of sockets 70-750DL8-1, 70-750E8-1, 70-464-1, 70-750E11-1, 70-750DL11-1, 70-465-1 -- 10 16-700DIN DIN Rail End Clip Holding the sockets firmly in place on a DIN rail -- -- 10 16-DCLIP-1 Description Metal Spring Clip Plastic ID Tag 40 Contents Legacy General Purpose Relays Sockets and Mounting Adapters bb Socket Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 bb Mounting Adapter Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 The following relay/socket combinations comprise a UL Listed assembly when used together. This added benefit allows for easier installation, since no enduse evaluations are required when using our relays or sockets with third-party components. UL Listed Relay/Socket Combinations 783XCX Relay with 70-783D11-1A Socket and 16-783SC Spring Clip Mating Relay(s) Number of Socket Pins Socket Part Number 781R 5 70-781D5R-1A 782 8 792XBX 8 70-782D8-1A 70-459-1 70-782EL8-1 70-782D14-1 792XDX 14 70-782E14-1 70-782EL14-1 70-461-1 783 11 70-783D11-1A 784 14 70-784D14-1 70-464-1 8 70-750E8-1 70-750EL8-1 70-750DL8-1 750R 70-465-1 11 70-750E11-1 70-750EL11-1 70-750DL11-1 788R 11 70-463-1 70-788EL11-1 70-782EL14-1 782H 14 70-782E14-1 70-782D14-1 70-461-1 8 750H 11 70-464-1 70-750E8-1 70-465-1 70-750E11-1 41 Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagrams Socket Specifications 70-124-2 Socket Specifications Part Number 70-124-2 Contact Configuration 3PDT Number of Terminals 11 Mounting Style Panel / Chassis Current Rating 15 A Nominal Voltage Rating 300 V Temperature Range Storage -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) Protection Category IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Screw Terminals Copper Alloy, Zinc Plated Screw Style -- Screw Size -- Maximum Screw Torque -- Terminal Connection Solder Terminal Layout Mix Maximum Wire Size Solid Copper (Output) 16 AWG, 1.0 mm Stranded Copper (Output) 16 AWG, 1.0 mm DIN Rail Mounting, EN 60715 -- Chassis Mount Screw Torque -- Flammability Rating 94V-0 Weight 12.1 g (0.43 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS Dimensions, in. (mm) Wiring Diagram 70-124-2 70-124-2 Recommended Chassis Cutout 1.5 (38.1) 0.297 (7.54) 0.28 (5.28) 0.02 (0.508) 1.25 (31.7) 1.68 (42.8) 1.68 (42.6) 1.27 (32.3) 1.37 (34.7) 2.03 (51.0) 0.165 (4.19) dia., 2 holes 0.5 (2.5) 0.29 (7.54) 0.63 (16.17) 0.24 (6.09) 1.37 (34.7) 0.18 (4.7) Typ. 70-124-2 3/16 Quick Connect Type Terminals 0.187 (4.7) 42 0.87 (22.2) 0.156 (3.9) dia. holes 1.39 (35.4) 1 (12) 2 (32) 3 (22) N.C. 4 (14) 5 (34) 6 (24) N.O. 7 (11) 8 (31) 9 (21) B (A2) A (A1) NEMA (IEC) COM Input Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagrams Socket Specifications 70-169-1 and 70-170-1 Socket Specifications Part Number 70-169-1 70-170-1 Contact Configuration DPDT 3PDT Number of Terminals 8 11 Mounting Style Panel Panel Current Rating 15 A 15 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category -- -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Terminal Layout Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 57 g (2.01 oz) 57 g (2.01 oz) Agency Approvals UL (E70550), CE, CSA (LR97899), RoHS UL (E70550), CE, CSA (LR97899), RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-170-1 2.0 (50.0) 0.629 (16.0) 1.68 (42.8) 0.25 (6.3) 2.5 (64.0) 2.2 (56.0) 4 9 3 5 3 4 7 2.25 (57.0) 8 6 2 6 0.625 (16.0) 0.25 (6.3) 5 70-169-1 1.29 (32.0) 1 0.17 dia. (4.3) 10 8 11 1 2 7 1.12 (28.0) 2.59 (65.0) 0.17 dia. (4.3) Wiring Diagrams 70-169-1 (22) 5 (24) 6 7 (A2) Input 5 4 6 3 2 7 8 70-170-1 (12) 4 1 8 1 (11) (21) NEMA (IEC) (14) 3 2 (A1) Input (24) 7 (32) 8 8 (21) 6 6 7 5 (22) 5 (12) 4 4 9 9 (34) 10 11 10 (A2) 11 Input (31) 3 2 1 3 (14) 2 (A1) 1 (11) Input NEMA (IEC) 43 Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagrams Socket Specifications 70-178-1 and 70-178-2 Socket Specifications Part Number 70-178-1 70-178-2 Contact Configuration 3PDT 3PDT Number of Terminals 11 11 Mounting Style Panel / PCB PCB Current Rating 15 A 15 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Style -- -- Screw Size -- -- Maximum Screw Torque -- -- Terminal Connection PCB PCB Terminal Layout Mix Mix 16 AWG, 1.0 mm 16 AWG, 1.0 mm Stranded Copper (Output) 16 AWG, 1.0 mm 16 AWG, 1.0 mm Temperature Range Maximum Wire Size Solid Copper (Output) DIN Rail Mounting, EN 60715 -- -- Chassis Mount Screw Torque -- -- Flammability Rating 94V-0 94V-0 Weight 12.1 g (0.43 oz) 12.1 g (0.43 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Dimensions, in. (mm) 70-178-1 70-178-2 0.297 (7.54) 1.5 (38.1) 0.02 (0.508) 2.03 (51) 1.37 (34.7) 1.37 (34.7) 0.165 (4.19) dia., 2 holes 0.5 (2.5) Wiring Diagram 70-178-1 and 70-178-2 44 2 (32) 5 (34) 3 (22) 6 (24) 7 (11) A (A1) 8 (31) 9 (21) B (A2) N.C. N.O. COM Input 0.317 (8.05) 0.175 (4.44) 0.175 (4.44) 0.055-0.062 (1.39-1.57) 1 (12) 4 (14) 0.43 (11) 0.035 (0.89) 1.25 (31.7) 1.68 (42.8) 0.317 (8.05) Recommended Circuit Board Layout For 70-178-1 & 70-178-2 Bottom View 0.875 (22.2) 1.5 (38.1) 0.297 (7.54) NEMA (IEC) 0.156 (3.96) 1.68 (42.6) 0.156 (3.96) 0.218 (5.5) 1 2 3 4 5 6 7 8 9 A 0.055-0.062 (1.39-1.57) 0.43 (11) B 0.546 (13.8) 0.844 (21.4) 0.078 (1.98) dia. 11 places 0.156 (3.9) dia. 2 holes Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-378-1 and 70-379-1 Socket Specifications Part Number 70-378-1 70-379-1 Contact Configuration 4PDT 4PDT Number of Terminals 14 14 Mounting Style Chassis PCB Current Rating 5A 5A Nominal Voltage Rating 120 V 120 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category -- -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Style -- -- Screw Size -- -- Maximum Screw Torque -- -- Terminal Connection Solder PCB Terminal Layout Mix Mix Solid Copper (Output) 18 AWG, 0.8 mm -- Stranded Copper (Output) 18 AWG, 0.8 mm -- DIN Rail Mounting, EN 60715 35 mm -- Chassis Mount Screw Torque 7 lb-in (0.8 N*m) -- Flammability Rating 94V-0 94V-0 Weight 6.2 g (0.22 oz) 5.8 g (0.20 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-378-1 0.44 (11.1) 0.86 (21.8) 0.375 (9.52) 0.18 (4.57) 0.10 (2.54) 0.105 0.10 (2.54) 1.14 (28.5) 0.015 (0.381) 0.145 (3.68) 0.39 (9.9) 0.65 (16.5) 0.16 dia. (4.06) 0.078 (1.98) 1.01 (25.7) Recommended Chassis Cutout Top View 0.05 (1.27) 0.16 (4.06) 0.07 (17.7) 0.44 (11.1) 0.05 (1.27) 0.86 (21.5) Ground Lug 0.125 (3.17) 0.375 (9.52) 0.102 (2.59) 0.07 dia. (1.77) 0.15 (3.81) 45 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-378-1 and 70-379-1 Dimensions, in. (mm) 70-379-1 0.44 (11.17) 0.375 (9.52) 0.75 (19.0) 0.105 (2.66) 0.015 (0.381) 0.1875 (4.76) 0.25 (6.35) 0.25 (6.35) 0.3 (7.82) 0.102 (2.6) 0.375 (9.5) Ground Lug 0.12 (3.04) 0.08 (2.03) 0.44 (11.1) 0.061 (1.54) 0.095 (2.4) 0.07 (1.78) dia. 14 places 0.16 dia. (4.06) 0.06 (1.52) 0.625 (15.8) 0.16 (4.06) 0.15 (3.81) 0.07 dia. (1.77) Wiring Diagrams 70-379-1 70-378-1 1 2 3 4 (12) (22) (32) (42) 5 6 7 8 (14) (24) (34) (44) 9 10 11 12 (11) (21) (31) (41) 13 14 (A1) (A2) NEMA (IEC) 46 Recommended Circuit Board Layout Top View 0.145 (3.68) dia. 1.0 (25.4) 0.674 (17.0) 0.525 (13.3) 0.35 (8.89) 0.175 (4.44) N.C. N.O. COM 2 3 4 1 (12) (22) (32) (42) 5 6 (14) (24) 9 10 (11) (21) Input Ground Lug 7 (34) 11 (31) 8 N.O. (44) 12 COM (41) 13 14 (A1) (A2) NEMA (IEC) N.C. Input Ground Lug 0.1 (2.5) Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-401-1 and 70-402-1 Socket Specifications Part Number 70-401-1 70-402-1 Contact Configuration DPDT DPDT Number of Terminals 8 8 Mounting Style Chassis PCB Current Rating 10 A 10 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category -- -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Style Combination Head -- Screw Size M3.5 mm -- Maximum Screw Torque 9 lb-in (1.0 N*m) -- Terminal Connection Solder PCB Terminal Layout Mix Mix Solid Copper (Output) 18 AWG, 0.8 mm -- Stranded Copper (Output) 18 AWG, 0.8 mm -- DIN Rail Mounting, EN 60715 -- -- Chassis Mount Screw Torque 7 lb-in (0.8 N*m) -- Flammability Rating 94V-0 94V-0 Weight 6.2 g (0.22 oz) 6.5 g (0.23 oz) Agency Approvals UL (E70550), CE, RoHS UL (E70550), CE, RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-401-1 0.43 (10.9) 0.075 (1.9) 0.39 (9.9) 0.185 (4.69) 0.078 (1.98) 0.07 (1.77) 0.35 (8.89) 0.83 (21) 0.86 (21.5) 0.417 (10.5) 0.1 (2.5) 0.18 (4.57) 1.14 (28.9) 0.072 x 0.140 (1.8 x 3.55) 0.702 (17.8) 1.01 (25.7) 0.3 (7.62) 0.155 dia. (3.93) Recommended Chassis Cutout Top View 0.012 (0.304) x8 47 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-401-1 and 70-402-1 Dimensions, in. (mm) 70-402-1 0.44 (11.1) 0.39 (9.9) 0.075 (1.9) 0.078 (1.98) Recommended Circuit Board Layout Top View 0.833 (21.1) 0.036 (0.91) 0.086 (2.18) dia. 8 places 1.14 (29.1) 0.18 (4.57) 0.394 (10.0) 0.185 (4.699) 0.672 (17.06) 0.078 (1.98) 0.62 (15.74) 0.3 (7.62) 0.243 (6.17) 0.155 dia. (3.93) 0.015 (0.381) Wiring Diagrams 70-401-1 70-402-1 1 (12) 5 (14) 4 (42) 8 (44) 9 (11) 12 (41) 14 (A2) 13 (A1) 1 (12) 5 (14) 4 (42) 8 (44) N.C. COM 9 (11) 12 (41) COM Input (A2) N.C. N.O. NEMA (IEC) 48 14 13 (A1) N.O. Input NEMA IEC 0.417 (10.59) Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-459-1, 70-461-1, and 70-463-1 Socket Specifications Part Number 70-459-1 70-461-1 70-463-1 Contact Configuration DPDT 4PDT 3PDT Number of Terminals 8 14 11 Mounting Style Panel or DIN rail Panel or DIN rail Panel or DIN rail Current Rating 10 A 10 A 15 A Nominal Voltage Rating 300 V 300 V 300 V Storage -40 to +105 C (-40 to +221F) -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +70 C (-40 to +158 F) -40 to +55 C (-40 to +131 F) Protection Category -- -- -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Combination Head Screw Size M3.5 mm M3 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 7 lb-in (0.8 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Screw Clamping Terminal Layout Mix Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 16-14 AWG (two 1.5-2.5 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 16-14 AWG (two 1.5-2.5 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 94V-0 Weight 50 g (1.76 oz) 50 g (1.76 oz) 51 g (1.79 oz) Agency Approvals UL (E70550), CE, CSA (LR97899), UL (E70550), CE, CSA (LR97899), UL (E70550), CE, CSA (LR97899), RoHS RoHS RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-459-1 70-461-1 0.708 (18) 1 7 3 2 8 8 5 4 1 4 2.51 (64.0) 2.73 (69.0) 1.02 (26.0) 6 2.52 (64.0) 5 0.708 (18.0) 2.71 (69.0) 0.16 (4.0) 14 13 12 9 1.03 1.17 (26.0) (29.0) 1.25 (32.0) 1.26 (32.0) 1 2 1.0 (25.4) 1 3 1 4 1 1 1 0 0.17 (4.32) Dia. Typ. 9 0.89 (22.7) 1.2 (30.7) 49 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-459-1, 70-461-1, and 70-463-1 Dimensions, in. (mm) 70-463-1 1 6 3 2 3.0 (76.0) 1.37 (35.0) 5 0.4 (10.0) 1.69 (43.0) 1.53 (39.0) 4 1.03 (26.0) 0.15 (3.81) 3.14 (80.0) B A 1.5 (38.0) 9 8 7 Wiring Diagrams 70-459-1 70-461-1 70-463-1 (44) (14) (34) (14) 5 (44) (34) (24) (14) 8 5 6 7 (24) 8 6 5 4 (42) (12) 4 1 (42) (32) (22) (12) 4 2 3 1 (22) (32) (12) 3 2 1 4 1 8 5 12 9 14 13 14 13 (A2) (A1) 12 (41) 9 (11) NEMA (IEC) 50 N.C. N.O. COM 4 3 2 1 8 7 6 5 12 11 10 9 14 3 2 1 N.O. 6 5 4 COM 9 8 7 COM A Input N.C. 13 Input Input Input 14 (A2) Input 13 (A1) 12 11 10 9 (41) (31) (21) (11) NEMA (IEC) B B (A2) Input A (A1) 9 8 7 (21) (31) (11) NEMA (IEC) N.C. N.O. Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagrams Socket Specifications 70-464-1 and 70-465-1 Socket Specifications Part Number 70-464-1 70-465-1 Contact Configuration DPDT 3PDT Number of Terminals 8 11 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 15 / 10 A 15 / 5 A Nominal Voltage Rating 300 / 600 V 300 / 600 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category -- -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Terminal Layout Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 40 g (1.41 oz) 57 g (2.01 oz) Agency Approvals UL (E70550), CE, CSA (LR97899), RoHS UL (E70550), CE, CSA (LR97899), RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-464-1 70-465-1 2.02 (51) 1 0.59 (15) 2 3 4 5 1.6 dia. (40.0) 0.16 (4.2) 2.12 (54) 1.01 (25.6) 2.32 (59.0) 0.97 (24.6) 1.29 (33) 8 1.6 (40) 7 0.97 (24.6) 1 3 4 1.02 (25.0) 6 2.06 (52.0) 2 5 2.05 (52.0) 11 10 6 7 9 8 2.16 (54.8) Wiring Diagrams 70-465-1 70-464-1 (11) (31) (A1) 1 11 (A2) (14) 2 10 (34) 3 Input 1 9 Input 11 (A1) (11) (21) (A2) 2 8 1 7 Input 1 Input 8 2 2 7 3 6 4 5 4 5 6 3 (14) (12) (22) (24) 10 3 NEMA (IEC) 4 (12) 4 8 5 5 (22) NEMA (IEC) 9 6 6 (21) 7 7 (24) 8 (32) 51 Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-750DL8-1 and 70-750DL11-1 Socket Specifications Part Number 70-750DL8-1 70-750DL11-1 Contact Configuration DPDT 3PDT Number of Terminals 8 11 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 16 A 16 A Nominal Voltage Rating 300 V 600 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Terminal Layout Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 60 g (2.12 oz) 78 g (2.75 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-750DL8-1 1.42 (36.0) 70-750DL11-1 1.45 (37.0) 1.42 (36.0) 1.1 (27.9) 3.0 (77.5) 22 11 12 5 1 4 24 21 14 6 8 3 3.19 (81.0) 3.02 (76.8) 2.86 (72.7) 1.58 (40.0) A2 INPUT 7 32 24 22 8 7 5 21 31 11 6 A1 INPUT 1.2 (30.0) 2 12 4 11 1 34 14 9 3 1.58 (40.0) IEC: NEMA: IEC: NEMA: 52 0.15 (3.8) 1.5 (38.0) 1.1 (27.9) A2 INPUT 10 A1 INPUT 2 1.35 (34.2) 0.15 (3.8) Legacy General Purpose Relays Wiring Diagrams, Specifications Socket Specifications 70-750DL8-1, 70-750DL11-1, 70-750E8, and 70-750E11-1 Wiring Diagrams 70-750DL8-1 70-750DL11-1 (22) (11) (12) (32) (24) (22) 5 1 4 8 7 5 (31) (21) 11 6 1 6 (14) 3 (24) (21) (14) 6 8 3 5 7 2 8 7 9 3 5 4 9 3 2 10 11 1 Input 7 8 Module Input Coil Bus Jumper (A2) 4 (11) (34) 4 6 (12) 1 Module Input Coil Bus 10 Jumper (A2) Input 2 2 (A1) NEMA (IEC) (A1) NEMA (IEC) Socket Specifications Part Number 70-750E8-1 70-750E11-1 Contact Configuration DPDT 3PDT Number of Terminals 8 11 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 12 A 12 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Elevator Elevator Terminal Layout Separate Separate Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 85 g (3.0 oz) 85 g (3.0 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size 53 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-750E8-1 and 70-750E11-1 Dimensions, in. (mm) 70-750E8-1 70-750E11-1 0.86 (22.0) 0.86 (22.0) 22 24 6 2.95 (75.0) 12 9 3 0.12 (3.1) 2.95 (75.0) 1.45 (37.0) INPUT A2 7 A2 1.06 (27.0) 2 IEC: NEMA: A2 21 7 7 1.49 (38.0) 11 8 0.12 (30.0) 1 1.06 (27.0) Wiring Diagrams 70-750EL8-1 70-750EL11-1 (22) (11) (12) (31) (21) (11) 5 1 4 11 6 1 (24) (21) (14) (32) (22) (12) 6 8 3 8 5 4 (34) (24) (14) 9 7 3 5 4 6 2 8 54 Coil Bus Jumper Input NEMA (IEC) 4 3 9 1 10 Module Input 7 5 8 7 (A2) 6 7 3 11 1 2 Module Input 2 (A1) 10 (A2) Coil Bus Jumper Input NEMA (IEC) 2 (A1) 3 4 INPUT A1 10 10 2 14 12 5 INPUT A2 A2 A2 A1 22 7 8 0.12 (3.1) 1.45 (37.0) INPUT A1 24 32 34 14 4 5 31 10 1.49 (38.0) 2 IEC: NEMA: 11 A1 21 11 6 0.12 (30.0) 1 2 Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-750EL8-1 and 70-750EL11-1 Socket Specifications Part Number 70-750EL8-1 70-750EL11-1 Contact Configuration DPDT 3PDT Number of Terminals 8 11 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 16 A 16 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Elevator Elevator Terminal Layout Separate Separate Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 79 g (2.79 oz) 79 g (2.79 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size Dimensions, in. (mm) 70-750EL8-1 1.77 (45.0) 70-750EL11-1 2.48 (63.0) 1.4 (36.0) 0.74 (19.0) 1.4 (36.0) 0.74 (19.0) 11 1 12 4 31 11 21 6 11 1 24 21 14 32 8 3 8 24 7 12 6 34 22 14 9 5 3 22 5 3.77 (96.0) 3.77 0.27 (96.0) (7.0) 3.62 (92.0) 3.62 (92.0) 4 0.27 (7.0) 1.60 (40.0) 1.60 (40.0) A2 7 IEC: NEMA: INPUT 1.18 (30.0) A1 2 A2 7 IEC: NEMA: INPUT A1 2 1.18 (30.0) 55 Legacy General Purpose Relays Wiring Diagrams, Specifications Socket Specifications 70-750EL8-1, 70-750EL11-1, 70-781D5R-1A, and 70-781T-1 Wiring Diagrams 70-750EL11-1 70-750EL11-1 (11) (31) (21) (11) (31) (21) 11 6 1 11 6 1 (32) (22) (12) (32) (22) (12) 8 5 4 8 5 4 (34) (24) (14) (34) (24) (14) 9 7 3 9 7 3 6 7 8 3 9 11 1 4 3 9 2 10 11 1 Coil Bus Jumper (A2) Input 2 Module Input Module Input 10 5 8 4 10 6 7 5 2 10 (A1) Coil Bus Jumper Input (A2) NEMA (IEC) 2 (A1) NEMA (IEC) Socket Specifications Part Number 70-781D5R-1A 70-781T-1 Contact Configuration SPDT SPDT Number of Terminals 5 5 Mounting Style Panel or DIN rail PCB Current Rating 16 A 10 A Nominal Voltage Rating 300 V 300 V Storage -40 to +85 C (-40 to +185 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 -- Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Copper Alloy, Zinc Plated Screw Style Combination Head -- Screw Size M3 mm / M3.5 mm -- Temperature Range Maximum Screw Torque M3 7 lb-in (0.8 N*m) M3.5 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping PCB Terminal Layout Mix Mix Solid Copper Two 12 AWG (two 4 mm) without cable end -- Stranded Copper Two 14 AWG (two 2.5 mm) with cable end -- DIN Rail Mounting, EN 60715 35 mm -- Chassis Mount Screw Torque 7 lb-in (0.8 N*m) -- Flammability Rating 94V-0 94V-0 Weight 31 g (1.09 oz) 18 g (0.63 oz) Agency Approvals UL (E70550), CE, CSA (168986), RoHS UL (E70550), CE, RoHS Maximum Wire Size 56 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-781D5R-1A and 70-781T-1 Dimensions, in. (mm) 70-781D5R-1A 70-781T-1 1.18 (30.0) 0.74 (19.0) 0.67 (17.0) 14 5 3.33 (84.0) 0.7 (18.0) 0.012 (0.3) 0.08 (2.03) 1.0 (25.0) 0.16 (4.0) 0.12 (3.0) A2 IEC: NEMA: INPUT 14 0.23 (5.8) Hole Size 0.07 (1.27) Dia. 3.14 (80.0) 1.57 (40.0) 0.185 (4.7) Hole Size 0.09 (2.28) Dia. 1.21 (30.9) 12 1 Recommended Printed Circuit Board Layout Top View 0.14 (3.55) 0.232 (5.9) 0.16 (4.0) 0.316 (8.0) A1 13 Coil Terminals 0.059 (1.49) Typ. 11 9 0.151 (3.8) 0.4 (12.1) 0.82 (21.0) Contact Terminals 0.079 (2.0) Typ. Wiring Diagrams 70-781D5R-1A 70-781T-1 (14) 5 (12) 1 1 N.C. 5 N.O. 9 COM 14 13 Input Module Input (A2) 14 1 (12) N.C. 5 (14) N.O. 9 (11) COM. (A2) 14 13 (A1) Input NEMA (IEC) 13 (A1) Input (11) 9 NEMA (IEC) 57 Legacy General Purpose Relays Specifications, Dimensions Socket Specifications 70-782D8-1A and 70-782D14-1 Socket Specifications Part Number 70-782D8-1A 70-782D14-1 Contact Configuration DPDT 4PDT Number of Terminals 8 14 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 16 A 10 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +70 C (-40 to +158 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 7 lb-in (0.8 N*m) Terminal Connection Screw Clamping Screw Clamping Terminal Layout Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 55 g (1.94 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size 62 g (2.19 oz) UL (E70550), CE, CSA (LR40787), RoHS Dimensions, in. (mm) 70-782D8-1A 70-782D14-1 0.74 (19.0) 1.57 (40.0) 44 14 8 5 42 12 1 3.33 (84.0) 4 3.14 (80.0) 0.16 (4.0) 3.11 (79.0) 2.4 (61.0) 2.67 (68.0) 3.3 (84.0) 1.57 (40.0) 1.18 (30.0) 58 INPUT IEC: NEMA: A2 INPUT A1 14 13 41 11 12 9 1.06 (26.0) 1.18 (30.0) 0.24 (6.0) 1.0 (25.5) 0.14 (3.8) 0.74 (19.0) 34 7 24 6 44 14 8 5 42 32 22 12 4 3 2 1 1.55 (39.5) 0.14 (3.8) 11 A2 A1 INPUT INPUT 14 13 41 31 21 12 11 10 0.82 (21.0) 1.18 (30.0) 9 0.25 (6.4) Legacy General Purpose Relays Wiring Diagrams Socket Specifications 70-782D8-1A, 70-782D14-1 Wiring Diagrams 70-782D8-1A 70-782D14-1 (44) 8 (14) 5 (42) 4 (12) (34) 7 (44) 8 1 4 1 8 5 12 9 14 13 N.C. N.O. COM Input Module Input 14 (A2) 13 Input (A1) 12 (41) 9 (11) NEMA (IEC) (24) 6 (14) 5 (42) (32) (22) (12) 4 3 2 1 4 3 2 1 8 7 6 5 12 11 10 9 14 13 N.C. N.O. COM Input Module Input 9 14 13 (11) (A2) (A1) Input 12 11 10 (41) (31) (21) NEMA (IEC) 59 Legacy General Purpose Relays Specifications Socket Specifications 70-782E14-1 and 70-782EL8-1 Socket Specifications Part Number 70-782E14-1 70-782EL8-1 Contact Configuration 4PDT DPDT Number of Terminals 14 8 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 10 A 12 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +70 C (-40 to +158 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3 mm M3.5 mm Maximum Screw Torque 7 lb-in (0.8 N*m) 9 lb-in (1.0 N*m) Terminal Connection Elevator Elevator Terminal Layout Separate Separate Solid Copper Two 16-14 AWG (two 1.5-2.5 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 16-14 AWG (two 1.5-2.5 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 56 g (1.98 oz) 46 g (1.62 oz) Agency Approvals UL (E70550) CE, CSA (LR40787), RoHS UL (E70550), CE, CSA (LR40787), RoHS Temperature Range Maximum Wire Size 60 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-782E14-1 and 70-782EL8-1 Dimensions, in. (mm) 70-782E14-1 70-782EL8-1 1.69 (43.0) 0.86 (22.0) 1.06 (26.9) 0.67 (17.0) 44 3.12 (79.0) 34 2.4 (61.0) 24 0.74 (19.0) 14 8 7 6 5 42 32 22 12 4 3 2 1 3.34 (85.0) 0.12 (3.0) 0.2 (5.6) 1.49 (38.0) A1 A2 14 INPUT 41 11 12 44 9 14 8 5 42 12 4 1 3.11 (79.0) IEC: NEMA: 1.57 (40.0) 1.06 (26.9) 0.9 (22.0) 13 41 31 21 11 A2 IEC: 12 11 10 9 14 NEMA: INPUT A1 13 Wiring Diagrams 70-782E14-1 70-782EL8-1 (44) (34) (24) (14) 8 7 6 5 (41) 12 (11) 9 (42) (32) (22) (12) 4 3 2 1 (44) 8 (14) 5 (42) 4 (12) 1 4 3 2 1 8 7 6 5 12 11 10 9 14 13 N.C. N.O. 4 1 8 5 COM 12 9 Input 14 13 Module Input 13 (A1) 12 11 10 9 (41) (31) (21) (11) NEMA (IEC) COM Input Module Input Input 14 (A2) N.C. N.O. 14 Input (A2) 13 (A1) NEMA (IEC) 61 Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagram Socket Specifications 70-782EL14-1 Socket Specifications Part Number 70-782EL14-1 Contact Configuration 4PDT Number of Terminals 14 Mounting Style Panel or DIN rail Current Rating 10 A Nominal Voltage Rating Temperature Range 300 V Storage -40 to +105 C (-40 to +221 F) Operating -40 to +70 C (-40 to +158 F) Protection Category IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Screw Style Combination Head Screw Size M3 mm Maximum Screw Torque 7 lb-in (0.8 N*m) Terminal Connection Elevator Terminal Layout Maximum Wire Size Separate Solid Copper Two 16-14 AWG (two 1.5-2.5 mm) Stranded Copper Two 16-14 AWG (two 1.5-2.5 mm) DIN Rail Mounting, EN 60715 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Weight 62 g (2.19 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS Dimensions, in. (mm) Wiring Diagram 70-782EL14-1 70-782EL14-1 2.4 (61.0) (41) (31) (21) (11) 12 11 10 9 0.9 (22) 1.06 (25.4) 0.74 (19.0) 3.34 (85.0) 0.2 (5.6) 41 31 21 12 11 10 9 44 34 24 14 11 8 7 6 5 42 32 22 12 4 3 2 1 (44) (34) (24) (14) 5 8 6 7 (42) (32) (22) (12) 1 2 3 4 4 3 2 1 8 7 6 5 12 11 10 9 14 13 3.11 (79.0) 1.49 (38.0) COM Input Module Input A2 IEC: NEMA: 14 INPUT 13 A1 14 Input (A2) NEMA (IEC) 62 N.C. N.O. 13 (A1) Legacy General Purpose Relays Specifications Socket Specifications 70-783D11-1A and 70-784D14-1 Socket Specifications Part Number 70-783D11-1A 70-784D14-1 Contact Configuration 3PDT 4PDT Number of Terminals 11 14 Mounting Style Panel or DIN rail Panel or DIN rail Current Rating 16 A 16 A Nominal Voltage Rating 300 V 300 V Storage -40 to +105 C (-40 to +221 F) -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) -40 to +55 C (-40 to +131 F) Protection Category IP20 IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Screw Size M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Terminal Layout Mix Mix Solid Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) Stranded Copper Two 14-12 AWG (two 2.5-4 mm) Two 14-12 AWG (two 2.5-4 mm) DIN Rail Mounting, EN 60715 35 mm 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 94V-0 Weight 55 g (1.94oz) 62 g (2.19 oz) Agency Approvals CE, RoHS, UL (E70550), CSA (LR40787) CE, RoHS, UL (E70550), CSA (LR40787) Temperature Range Maximum Wire Size 63 Legacy General Purpose Relays Dimensions, Wiring Diagrams Socket Specifications 70-783D11-1A and 70-784D14-1 Dimensions, in. (mm) 70-784D14-1 70-783D11-1A 1.10 (28.0) 0.74 (19.0) 0.74 (19.0) 44 24 14 44 34 24 8 6 5 8 7 6 5 42 22 12 32 22 12 4 2 1 42 4 3 2 1 3.14 (80.0) 3.33 (84.0) 0.16 (4.0) INPUT 14 13 41 21 11 12 10 9 1.45 (37.0) 1.57 (40.0) A1 0.24 (6.0) 70-783D11-1A (44) 70-784D14-1 (24) 6 (14) (44) (14) 5 (34) (24) 8 8 7 6 5 (42) (22) (12) 4 2 (42) (32) (22) (12) 1 4 3 2 1 4 2 1 8 6 5 12 10 9 14 13 N.C. N.O. COM 4 3 2 1 8 7 6 5 12 11 10 9 (A2) Input 13 (A1) 14 (A2) 13 Input (A1) 12 10 9 12 11 10 9 (41) (21) (11) (41) (31) (21) (11) NEMA (IEC) 64 N.O. COM Module Input Module Input 14 N.C. Input Input NEMA (IEC) 13 14 41 31 21 11 12 11 10 9 0.24 (6.0) 1.96 (50.0) Wiring Diagrams 2.67 (68.0) INPUT A1 1.81 (46.0) 1.18 (30.0) 1.57 (40.0) INPUT A2 14 3.14 (80.0) IEC: NEMA: INPUT A2 1.18 (30.0) 3.33 (84.0) 0.16 (4.0) 2.67 (68.0) IEC: NEMA: 1.57 (40.0) 1.41 (36.0) Legacy General Purpose Relays Specifications, Dimensions, Wiring Diagrams Socket Specifications 70-788EL11-1 Socket Specifications Part Number 70-788EL11-1 Contact Configuration 3PDT Number of Terminals 11 Mounting Style DIN rail Current Rating 25 A Nominal Voltage Rating 300 V Temperature Range Storage -40 to +105 C (-40 to +221 F) Operating -40 to +55 C (-40 to +131 F) Protection Category IP20 Internal Metal Tracks Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Screw Style Combination Head Screw Size M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) Terminal Connection Elevator Terminal Layout Separate Maximum Wire Size Solid Copper Two 14-10 AWG (two 2.5-6 mm) Stranded Copper Two 14-10 AWG (two 2.5-6 mm) DIN Rail Mounting, EN 60715 35 mm Chassis Mount Screw Torque 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Weight 96 g (3.39 oz) Agency Approvals UL (E70550), CE, CSA (LR40787), RoHS Dimensions, in. (mm) Wiring Diagram 70-788EL11-1 70-788EL11-1 2.48 (63.0) 21 3.7 (96.0) 31 11 9 8 7 24 34 14 6 5 4 22 32 12 3 2 1 (21) 9 (31) 8 (11) 7 (24) 6 (34) 5 (14) 4 (22) 3 (32) 2 (12) 1 3 6 9 2 5 1 8 B 4 7 A 3.62 (92.0) N.C. N.O. COM Input Module Input B A2 7 IEC: NEMA: INPUT 1.4 (36.0) A1 2 (A2) Coil Bus Jumper A (A1) Input Input NEMA (IEC) 65 Legacy General Purpose Relays Specifications, Dimensions Mounting Adapter Specifications Mounting Adapter Specifications Part Number 16-781C Mounting Style DIN rail / panel Mating Relays 781R Series Agency Approvals RoHS 16-782C 16-783C 16-784C 792 Series 782 Series 783 Series 784 Series 16-781C1 16-782C2 16-783C1 16-784C1 Panel Key Features 781R Series 792 Series 782 Series 783 Series 784 Series bb Low profile bb Write-on label bb Narrow mounting bb Easy termination bb No socket needed bb DIN or panel mounting bb Plastic construction bb Light weight bb Low cost Mounting Adapter Dimensions, in. (mm) 16-781C All DIN Adapters 16-784C 0.87 (22.2) 0.87 (22.2) 0.76 (19.2) 0.77 (19.6) 1.5 (38.0) 1.84 (46.7) Max. 1.39 (35.2) 16-783C 16-782C 0.15 (3.9) 0.24 (6.1) 0.3 (7.6) 0.29 (7.4) 0.29 (7.4) 1.97 (50.0) Max. 2.06 (52.2) Max. 0.67 (17.0) 0.93 (23.7) 16-781C1 16-782C1 All Flange Adapters 43.2 (43.2 Max.) 0.18 (4.6) 0.67 (17.0) 66 1.5 (38.0) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.94 (24.0) 0.61 (15.6) 1.5 (38.0) 0.14 (3.6) 0.14 (3.6) 16-784C1 0.72 (18.3) 1.5 (38.0) 1.5 (38.0) 1.72 (43.6) 16-783C1 0.72 (18.3) 0.6 (15.6) 42.8 (42.8 Max.) 1.32 (33.5) 0.15 (3.8) 1.34 (34.0) 0.15 (3.8) 1.34 (44.0) Overview Legacy General Purpose Relays Socket Accessories Product Overview Hold-Down Clips For safely securing the relay to the socket. Available in plastic or stainless steel. Socket Modules For optional circuit protection (diode, MOV, or RC) or status indicator LED. Modules plug into mating sockets. DIN Rail and Locking End Clip For quick installation and removal of sockets. Write-on ID Tags Insulated Coil Bus Jumper System For connection to adjacent sockets without tools or additional wiring. For identification of relays in multi-relay circuits. The tag snaps onto the mating socket. 67 Legacy General Purpose Relays Selection Socket Accessories Hold-Down Clips Use the table below to select Schneider Electric hold-down clips based on socket and relay compatibility. Key Features bb Stainless steel spring clips: secure the relay to the socket in harsh environments bb Plastic ejector clips: secure and eject relays from tight, multi-socket applications bb Plastic ID clips: easily identify circuits in multi-relay applications; include an ID tag with each clip Socket Part Number Relays Clip Part Number Clip Type 70-124-2 788XBXR / 788XCXR 16-1351 Spring Clip 70-178-1 788XBXR / 788XCXR 16-1351 Spring Clip 70-178-2 788XBXR / 788XCXR 16-1351 Spring Clip 70-378-1 792XDX Control, 782XDXH 16-1342 Spring Clip 70-379-1 792XDX Control, 782XDXH 16-1342 Spring Clip 70-401-1 782XBX Power 16-1342 Spring Clip 70-402-1 782XBX Power 16-1342 Spring Clip 70-459-1 782XBX Power 16-1342 Spring Clip 70-461-1 792XDX Control, 782XDXH 16-1342 Spring Clip 70-463-1 788XBXR / 788XCXR 16-1351 Spring Clip 70-464-1 750XBXR, 750XBXH 16-1351 Spring Clip 70-465-1 750XCXR, 750XCXH 16-1351 Spring Clip 70-750DL8-1 750XBXR 16-1332 Spring Clip 750XBXH 16-1351 Spring Clip 750XCXR 16-1332 Spring Clip 750XCXH 16-1351 Spring Clip 750XBXR 16-1344 Spring Clip 750XBXR, 750XBXH 16-1351 Spring Clip 70-750E11-1 750XCXR, 750XCXH 16-1351 Spring Clip 70-750EL8-1 750XBXR 16-1351 Spring Clip 70-750EL11-1 750XCXR 16-1351 Spring Clip 70-781D5R-1A 781XAXR 16-781IDC ID Clip 16-781SC Spring Clip 70-750DL11-1 70-750E8-1 70-781T-1 781XAXR 16-781SC Spring Clip 70-782D8-1A 782XBX Power 16-1342 Spring Clip 16-782IDC ID Clip 782XBX Power (full-feature cover only) 16-782PC-1 Ejector Clip 792XBX / 792XDX Control 16-782SC Spring Clip 792XBX / 792XDX Control (full-feature cover only) 16-782PC-1 Ejector Clip 782XDXH 16-1342 Spring Clip 792XBX / 792XDX Control 16-782SC Spring Clip 792XBX / 792XDX Control (full-feature cover only) 16-782PC-1 Ejector Clip 782XDXH 16-1342 Spring Clip 792XBX Control 16-782SC Spring Clip 792XBX Control (full-feature cover only) 16-782PC-1 Ejector Clip 792XBX / 792XDX Control 16-782SC Spring Clip 792XBX / 792XDX Control (full-feature cover only) 16-782PC-1 Ejector Clip 782XDXH 16-1342 Spring Clip 783XCX 16-783IDC ID Clip 16-783SC Spring Clip 16-784IDC ID Clip 16-784SC Spring Clip 16-1351 Spring Clip 70-782D14-1 70-782E14-1 70-782EL8-1 70-782EL14-1 70-783D11-1A 70-784D14-1 70-788EL11-1 68 784XDX 788XBXR / 788XCXR Legacy General Purpose Relays Dimensions Socket Accessories Hold-Down Clips Hold-Down Clip Dimensions, in. (mm) 16-781IDC 16-782IDC 16-781SC 0.56 (14.2) 0.4 (10.16) 0.14 (3.5) 0.4 (10.16) 0.51 (13.0) 1.76 (44.7) 1.84 (46.73) 0.88 (22.35) 1.59 (40.5) 0.085 (2.15) 0.935 (23.74) 0.54 (13.71) 0.725 (18.41) 16-782PC 0.85 (21.59) 1.01 (25.65) 0.08 (2.03) 16-782SC 16-783IDC 0.86 (22.0) 0.966 (24.54) 0.23 (6.0) 0.5 (12.8) 0.4 (10.16) 1.86 (47.24) 1.49 (38.0) 2.211 (56.15) 1.0 (25.4) 0.08 (2.03) 1.063 (26.99) 16-783SC 1.24 (31.5) 0.28 (7.0) 1.55 (39.5) 0.50 (12.8) 16-784IDC 16-784SC 1.61 (41.0) 0.4 (10.16) 1.8 (45.7) 1.27 (32.25) 1.44 (36.57) 0.28 (7.0) 0.5 (12.8) 1.5 (38.0) 0.9 (22.86) 1.6 1.76 (40.6) (44.7) 69 Legacy General Purpose Relays Dimensions Socket Accessories Hold-Down Clips Hold-Down Clip Dimensions (continued), in. (mm) 16-1332 16-1342 1.55 (39.37) 1.016 (25.81) 0.284 (7.21) 1.394 (35.41) 2.2 (55.0) 1.099 (27.92) 16-1344 1.665 (42.28) 16-1351 0.182 (4.62) 2.8 (71.12) 0.3 (7.62) 2.15 (54.61) 1.32 (33.5) 70 1.377 (34.77) Legacy General Purpose Relays Dimensions Socket Accessories Insulated Coil Bus Jumper, DIN Rail and Clip, and ID Tags Insulated Coil Bus Jumper Dimensions, in. (mm) 16-750/788CBJ-1 Coil Bus Jumper 1.37 (35) 1.25 (32) 16-750/788CBJ-1 Coil Bus Jumper 0.98 (25.0) 0.12 (3.2) 0.3 (8.3) 0.09 (2.3) 0.84 (21.5) 0.02 (0.64) 0.10 (2.6) 0.29 (7.4) 0.09 (2.3) 0.02 (0.64) DIN Rail and DIN Clip Dimensions, in. (mm) 16-700DIN Metal DIN Rail 16-DCLIP-1 DIN Rail Clip 39.3 (1000) 0.3 (7.5 +0.0/-0.4) 0.37 (9.4) 1.377 +0.011/-0.007 (35.0 0.3) 1.55 (39.5) The lips at base of the DIN rail may or may not be present on DIN rail extrusions. 1.0 (25.5) 0.19 (5) 0.39 (10.0) 0.99 (25.0) 1.65 (42.0) 1.39 (35.5) 0.86 (22.0) 0.039 (1.0 0.04) 1.37 (34.7) 1.17 (29.7) ID Tag Dimensions, in. (mm) 16-700ST-1 ID Tag/Label 0.46 (11.8) 16-750/788FT-1 ID Tag/Label 0.19 (4.8) 0.12 (3.7) 16-782FT-1 ID Tag/Label 1.06 (27.0) 1.2 (32.0) 0.47 (12.0) 0.55 (14.2) 1.07 (27.4) 0.45 (11.5) 0.55 (14.2) 0.9 (23.0) 71 Legacy General Purpose Relays Dimensions Socket Accessories Panel Mount Adapter and Socket Modules Panel Mount Adapter Dimensions, in. (mm) 16-788C1 Panel Mount Adapter 0.17 Typ. (4.31) 0.06 Typ. (1.4) 0.256 (6.5) 0.12 (3.04) 1.39 Max. (35.3) 0.165 (4.19) 0.165 Typ. (4.19) 1.4 Max. (35.5) 0.585 (14.95) 1.7 (43.18) Socket Module Dimensions, in. (mm) 70-BSM Socket Modules 70-ASM Socket Modules 1.37 (34.7) 0.384 (9.82) 0.49 (12.4) 0.34 (8.63) LED (only on LED modules) 1.05 (26.67) Max. 1.60 Max. A2 A2 A1 Socket Module Wiring Diagrams 70-ASM & 70-BSM Socket Modules LED Indicator A2 70-ASMLG 70-BSMLG Protection Diode A2 70-ASMD 70-BSMD 72 + A1 + A1 A2 MOV Suppressor 70-ASMM 70-BSMM A1 RC Suppressor A2 A1 70-ASMR 70-BSMR A1 Legacy General Purpose Relays Application Data General Purpose Relays Typical Electromechanical Relay General purpose relays are electromechanical relays which consist of a coil, armature, and contacts (see the figure at left). Principle of Operation Coil When power is applied to the coil, the resulting magnetic field causes the armature to move, and the contacts to open or close. Armature Mechanical Contacts Applications With multiple options, features, and available accessories, our general purpose relays offer a complete system solution to improve your design, speed up installation, and simplify testing of your application. Typical Examples of General Purpose Relay Applications Automation Panels Food & Beverage Packaging Machinery Lighting Control Power Supplies Material Handling HVAC & Refrigeration Appliances Process controls, motor controls, standby lighting Conveyor motors, food processors, product/shrink wrap, solenoid controls Universal power supplies, battery backup systems Anti-condensation equipment, compressor controls, blower controls, motorized duct/vent controls Commercial/industrial cooking equipment, filtration systems, bottling, chillers, convection ovens Traffic signal systems, motorway information systems, theatrical lighting, ballast lighting Motor control, conveyor controls Air conditioners, water heaters, portable heaters, spa controls, water pumps 73 Website Guide Legacy General Purpose Relays The Legacy Relays website (www.serelays.com) is designed to help you easily find the proper relay to fit your design requirements, and to help you simplify and shorten your workflow. Easily find the proper relay to fit your design requirements b Online Catalog Find the right product by choosing specifications, comparing products side-byside, and viewing technical specifications, 2D and 3D drawings, and associated accessories. b Cross-Reference Search Search our comprehensive database to identify products by manufacturer and part number, and link directly to part specifications. b 3D CAD Library View, email, download, or insert a file directly into your open CAD software. Choose from 18 file formats. 3D Models b Order Free Samples Schneider Electric offers free samples as a courtesy to individuals and companies evaluating our products for their designs and applications. Sample orders are subject to approval. Simplify and shorten your workflow b Interactive Tools View interactive demonstrations, such as our Time Delay Relay Interactive Demo (left), which visually demonstrates the ten different timing functions offered. b Distributor Inventory Search Search authorized distributors' current Schneider Electric inventory and buy online. (Buy online is not available for all distributors). Time Delay Relay Demo 74 Index Legacy General Purpose Relays 16-700DIN 8, 12, 16, 20, 24, 28, 32, 36, 40 16-700ST-1 8, 16 16-750/788CBJ-1 28, 32, 40 16-750/788FT-1 28, 32, 40 16-781C 12, 65 16-781C1 12, 65 16-781IDC 12, 67 16-781SC 12, 67 16-782C 8, 16, 65 16-782C1 8, 16 16-782C2 65 16-782CBJ-1 8, 36 16-782FT-1 8, 36 16-782IDC 16, 67 16-782PC-1 8, 16, 67 16-782SC 8, 67 16-783C 20, 65 16-783C1 20, 65 16-783IDC 20, 67 16-783SC 20, 67 16-784C 24, 65 16-784C1 24, 65 16-784IDC 24, 67 16-784SC 24, 67 16-1332 28, 67 16-1342 16, 36, 67 16-1344 28, 32, 67 16-1351 28, 32, 40, 67 16-DCLIP-1 8, 12, 16, 20, 24, 28, 32, 36, 40 70-124-2 32, 42 70-169-1 28, 40, 43 70-170-1 28, 40, 43 70-178-1 32, 44 70-178-2 32, 44 70-378-1 8, 36, 45 70-379-1 8, 36, 45 70-401-1 16, 47 70-402-1 16, 47 70-459-1 16, 41, 49 70-461-1 8, 36, 41, 49 70-463-1 32, 41, 49 70-464-1 28, 40, 41, 51 70-465-1 28, 40, 41, 51 70-750DL8-1 28, 40, 41, 52 70-750DL11-1 28, 40, 41, 52 70-750E8-1 28, 40, 41, 53 70-750E11-1 28, 40, 41, 53 70-750EL8-1 28, 41, 55 70-750EL11-1 28, 41, 55 70-781D5R-1A 12, 41, 56 70-781T-1 12, 56 70-782D 8 70-782D8-1A 16, 41, 58 70-782D14-1 36, 41, 58 70-782E 8 70-782E14-1 36, 41, 59 70-782EL8-1 41, 59 70-782EL14-1 36, 41, 61 70-783D11-1A 20, 41, 62 70-784D14-1 24, 41, 62 70-788EL11-1 32, 41, 64 70-ASM 20, 24, 28, 32 70-BSM 8, 12, 16 750XBXH 37, 38 750XBXR 25, 26 750XCXH 37, 38 750XCXR 25, 26 781XAXR 9, 10 782XBX 14 782XBXC 13 782XBXCL 13 782XBXCT 13 782XBXM4L 13 782XDXH10 33, 34 782XDXH21 33, 34 783XCX 17, 18 784XDX 21, 22 788XBXR 29, 30 788XCXR 29, 30 792XBX 4, 5 792XDX 4, 6 75 Schneider Electric USA, Inc. 200 N. Martingale Rd. Schaumburg, IL 60173 Tel: 847-441-2540 www.serelays.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. (c) 2011-2017 Schneider Electric. All Rights Reserved. Schneider Electric is a trademark and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. All other trademarks are the property of their respective owners. 8501CT1105R01/17, 01/2017 Replaces 8501CT1105R10/15 dated 10/2015