www.cor.com - Libertyville, IL (847) 680-7400
DC Series
The DC series filters were designed as general purpose
line filters for DC applications. They are available with or
without circuit breakers for extra protection. They will also
be available soon with feed-through capacitors for added
performance (contact factory for more information). The
DC series is designed to comply with UL 1283, CSA 22.2
No. 8 and EN60950.
The DC series was developed in response to the
increasing demand for DC filtering in the telecom-datacom
market. These filters are generally used in central office
equipment like switches, routers, and hubs to clean up the
48 VDC power, but are not exclusive to that equipment.
They can also be used at the primary input of the DC
power supply.
RFI Power Line Filters
Line Filters for DC Applications
Specifications
Hipot rating (one minute):
line-to-ground2250VDC
line-to-line1450VDC
Operating Voltage (max):80VDC
Operating ambient temp. range:-10
o
C to 55
o
C
In an ambient, T
o
, higher than 55
o
C, the maximum
operating current, I
o
, is as follows:
Minimum insertion loss in dB:
*
Line-to-line in 50 ohm circuit
CurrentFrequency-MHz
Rating.01.05.1.15.51351030
15A-11220414561634739
30A-41523475964564436
60A--917294059503934
100A- - 1018383953503521
125A-11220414561634739
Line-to-ground in 50 ohm circuit
CurrentFrequency-MHz
Rating.01.05.1.15.51351030
15A7222730303656493831
30A7222831325956514128
60A15303640403560513932
100A14293539333053534130
125A7222730303656493831
* Contact factory for insertion loss data on high performance versions.
DC Series
Standard Performance Version
High Performance Version
UL Recognized*
CSA Certified*
TUV Approved*
*
Approvals pending
Electrical Schematics
85 - T
o
30
I
o= I
r
Note 2
Note 1
Note 4
Resistor location for reference only.
Note 1:Depicts style 6 terminals are redundant.
Note 2:Depicts optional circuit breaker.
Note 3:For 100 & 125A versions delete second coil.
Note 4:Depicts style 10 terminal versions have seperate ground stud.
Note 1
Note 2Note 3
Note 4
Note 1
Note 1
Available Part Numbers
15DCF615DCB6B15DCF1015DCB10B
30DCF630DCB6B30DCF1030DCB10B
60DCF660DCB6B60DCF1060DCB10B
100DCF615DCB6F100DCF1015DCB10F
125DCF630DCB6F125DCF1030DCB10F
15DCF6B60DCB6F15DCF10B60DCB10F
30DCF6B100DCB6F30DCF10B100DCB10F
60DCF6B125DCB6F60DCF10B125DCB10F
15DCB615DCB6BF15DCB1015DCB10BF
30DCB630DCB6BF30DCB1030DCB10BF
60DCB660DCB6BF60DCB1060DCB10BF
100DCB6100DCB10
125DCB6125DCB10
Contact factory for availability of 100 & 125 amp circuit breaker versions.
Libertyville, IL (847) 680-7400 - www.cor.com
Series DC
Current Rating
15, 30, 60, 100, 125A Options
B- Circuit Breaker
F- Feedthru Capacitors for
High Performance
BF- Circuit Breaker and Feedthru
Capacitors
Termination Style
6- Redundant Stud
10- Phoenix Terminal
Mounting Style
F- Flange Mounting
B- Bulkhead and Rack Mounting
Series Name
DC- Series Name
60DCB6B
Ordering Information
Consult your local Corcom sales representative for pricing
Terminations
Style 6 (15, 30 & 60A)
Supplied with #10-32 redundant studs - 0.625” spacing.
Style 6 (100 & 125A)
Supplied with 1/4-20 redundant studs - 0.75” spacing
Style 10 (15 & 30A)
Phoenix Contact P/N VDFK4
Accepts 12 AWG stranded wire
Torque Spec: 5.5 - 7.0 in-lb.
Ground Stud 8-32
Style 10 (60A)
Phoenix Contact P/N HDFK 16-VP
Accepts 6 AWG stranded wire
Torque Spec: 17.7 - 21.2 in-lb.
Ground Stud 10-32
Style 10 (100A)
Phoenix Contact P/N HDFK 25-VP
Accepts 4 AWG stranded wire
Torque Spec: 35.4 - 39.9 in-lb.
Ground Stud 1/4 - 20
Style 10 (125A)
Phoenix Contact P/N HDFK 50-VP
Accepts 1 AWG stranded wire
Torque Spec: 35.4 - 39.9 in-lb.
Ground Stud 1/4 - 20
Cutout Dimensions
Metric shown in italics.
PartABCDEFFig.
Number
15DCB61.3751.2493.472 1
34.9331.7288.19
15DCB6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
15DCB100.7811.2183.472 1
19.8430.9488.19
15DCB10B1.4490.7561.3083.4721.2180.781 2
36.8019.2033.2288.1930.9419.84
15DCF6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
15DCF10B1.4490.7561.3083.4721.2180.781 2
36.8019.2033.2288.1930.9419.84
30DCB61.3751.2493.472 1
34.9331.7288.19
30DCB6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
30DCB100.7811.2183.472 1
19.8430.9488.19
30DCB10B1.4490.7561.3083.4721.2180.781 2
36.8019.2033.2288.1930.9419.84
30DCF6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
30DCF10B1.4490.7561.3083.4721.2180.781 2
36.8019.2033.2288.1930.9419.84
60DCB61.3751.2493.472 1
34.9331.7288.19
60DCB6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
60DCB101.0051.6353.462 1
25.5341.5387.93
60DCB10B1.4490.7561.3083.4621.0051.6352
36.8019.2033.2287.9325.5341.53
60DCF6B1.4490.7561.3083.4721.3751.249 2
36.8019.2033.2288.1934.9331.72
60DCF10B1.4490.7561.3083.4621.0051.6352
36.8019.2033.2287.9325.5341.53
100DCB61.7001.5493.221 1
43.1839.3481.81
100DCB101.2812.0002.244 1
32.5450.8057.00
125DCB61.7001.5493.221 1
43.1839.3481.81
125DCB101.5622.1882.180 1
39.6755.5855.37
Recommended Panel Cutouts
Fig. 1
Recommended Panel Cutouts
Fig. 2
Holes:
.157Dia.(4)
3.99
Holes:
.157Dia.(4)
3.99
DCSeries
www.cor.com - Libertyville, IL (847) 680-7400
Fig. 3
Fig. 4
Fig. 5
Fig 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Case Style
Metric shown in italics.
Note:15DCF6 & 30DCF6 versions come with mounting
holes in place of mounting slots.
Typical dimensions
Mounting slots: (4)
.
260 x .39
6.6 x 9.9
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Tapped insert: 6-32 (4)
Typical dimensions
Mounting slots: (4)
.
260 x .39
6.6 x 9.9
Typical dimensions
Mounting holes: (4)
.
156 x .203
4.0 x 5.2
Typical dimensions
Mounting slots: (4)
.
260 x .39
6.6 x 9.9
Typical dimensions
Mounting slots: (4)
.
260 x .39
6.6 x 9.9
Note: Delete circuit breaker for DCB10 models
Note: Delete circuit breaker for DCB6 models
Note: Delete circuit breaker for DCB10 models
Case Dimensions
Metric shown in italics.
PartABCDEFFig.
Number(max)(max)(max)(max)
15DCB65.665.061.464.5004.060.950 6
143.8128.537.0114.30103.124.13
15DCB6B7.825.061.464.5006.060.950 6
198.6128.537.0114.30153.924.13
15DCB104.885.061.464.5004.060.950 3
123.8128.537.0114.30103.124.13
15DCB10B7.065.061.464.5006.060.950 3
179.3128.537.0114.30153.924.13
15DCF65.333.101.782.6773.702.000 8
135.478.745.268.0094.050.80
15DCF6B7.695.061.465.7406.063.520 7
195.3128.537.0145.80153.989.41
15DCF104.603.101.782.6773.702.000 4
116.878.745.268.094.050.80
15DCF10B7.065.061.465.7406.063.5205
179.3128.537.0145.80153.989.41
30DCB67.695.061.464.5006.060.950 6
195.3128.537.0114.30153.924.13
30DCB6B8.695.061.464.5007.060.950 6
220.7128.537.0114.30179.324.13
30DCB106.885.061.464.5006.060.950 3
174.6128.537.0114.30153.924.13
30DCB10B8.065.061.464.5007.060.950 3
204.7128.537.0114.30179.324.13
30DCF66.193.962.183.5004.562.000 8
157.2100.655.488.90115.850.80
30DCF6B8.695.001.465.7407.064.520 7
220.7127.037.0145.80179.3114.81
30DCF105.953.962.183.5004.562.000 4
151.1100.655.488.90115.850.80
30DCF10B8.065.061.465.7407.064.5205
204.7128.537.0145.80179.3114.81
60DCB68.695.061.464.5007.060.950 6
220.73128.537.0114.30179.324.13
60DCB6B10.695.061.464.5009.060.950 6
271.5128.537.0114.30230.124.13
60DCB109.755.061.464.5007.060.950 9
247.7128.537.0114.30179.324.13
60DCB10B11.755.061.464.5009.060.950 9
298.5128.537.0114.30230.124.13
60DCF67.565.482.554.9205.942.756 8
192.0139.264.8124.97150.970.00
60DCF6B10.695.061.465.7409.066.520 7
271.5128.537.0145.80230.1165.61
60DCF108.505.482.554.9205.942.57611
215.9139.264.8124.97150.965.43
60DCF10B11.755.061.465.7409.066.52010
298.5128.537.0145.80230.1165.61
100DCB6,10.315.061.784.5008.060.950 6
125DCB6261.9128.545.2114.30204.724.13
100DCF6,10.606.302.525.7008.464.583 8
125DCF6269.2160.064.0144.78214.9116.41
100DCB1011.135.061.784.5008.060.950 9
282.6128.545.2114.30204.724.13
100DCF1011.506.302.525.7008.464.58311
292.1160.064.0144.78214.9116.41
125DCB1011.505.061.784.5008.060.950 9
292.1128.545.2114.30204.724.13
125DCF1011.756.302.525.7008.464.58310
298.5160.064.0144.78214.9116.41
Libertyville, IL (847) 680-7400 - www.cor.com
Series DC
Case Style
Metric shown in italics.
Fig. 11
Typical dimensions
Mounting slots: (4)
.
260 x .39
6.6 x 9.9