Functional Diagram and Ordering Information appear at
end of data sheet.
General Description
The MAX3107 is an advanced universal asynchronous
receiver-transmitter (UART) with 128 words each of
receive and transmit first-in/first-out (FIFO) that can be
controlled through I2C or high-speed SPI. The 2x and
4x rate modes allow a maximum of 24Mbps data rates.
A phase-locked loop (PLL), prescaler, and fractional
baud-rate generator allow for high-resolution baud-rate
programming and minimize the dependency of baud rate
on reference clock frequency.
Autosleep and shutdown modes help reduce power con-
sumption during periods of inactivity. A low 640µA (typ)
supply current and tiny 24-pin TQFN (3.5mm x 3.5mm)
package make the MAX3107 ideal for low-power portable
devices.
Integrated logic-level translation on the controller and
transceiver (RX/TX and RTS/CTS) interfaces enable use
with a wide selection of RS-232/RS-485 transceivers.
Automatic hardware and software flow control with select-
able FIFO interrupt triggering offloads low-level activity
from the host controller. Automatic half-duplex transceiver
control with programmable setup and hold times allow
the MAX3107 to be used in high-speed applications, for
example Profibus-DP.
The MAX3107 is ideal for use in portable devices,
industrial, and automotive applications. The MAX3107 is
available in a 24-pin SSOP package and a 24-pin TQFN
package. It is specified over the -40°C to +85°C extended
ambient temperature range.
Applications
Portable Devices
Industrial Control Systems
Fieldbus Networks
Automotive Infotainment Systems
Medical Systems
Point-of-Sale Systems
HVAC or Building Control
Benets and Features
Bridges an SPI/MICROWIRE or I2C Microprocessor
Bus to an Asynchronous Interface Such as RS-485,
RS-232, or IrDASM
SIR- and MIR-Compliant IrDA Encoder/Decoder
Line Noise Indication Ensures Data Link Integrity
Saves Up to 23% Board Space
24-Pin TQFN (3.5mm x 3.5mm) and SSOP Packages
Integrated Internal Oscillator Eliminates the Need for
an External Oscillator and Reduces the BOM Cost
Integrated PLL and Divider
Fast Data Rates Allow Maximum System Flexibility
Across Interface Standards
24Mbps (max) Data Rate
Fractional Baud-Rate Generator
SPI Up to 26MHz Clock Rate
Deep, 128-Word Buffer and Automated Control
Features Help Offload Activity on the Microcontroller
Auto Transceiver Direction Control
Half-Duplex Echo Suppression
Auto RTS/CTS and XON/XOFF Flow Control
9-Bit Multidrop-Mode Data Filtering
- Special Character Detection
- GPIO-Based Character Detection
- Four Flexible GPIOs
Power Management Control Features Minimize
Power Consumption for Portable Applications
+2.35V to +3.6V Supply Range
- Low 640μA (typ) Supply Current at 1Mbaud and
20MHz Clock
Shutdown and Autosleep Modes
- Low 20μA (typ) Shutdown Power
Logic-Level Translation on the Controller and
Transceiver Interfaces (Down to 1.7V) Ensure
System Compatibility
Register Compatible with MAX3108, MAX3109,
MAX14830
MAX3107 SPI/I2C UART with 128-Word FIFOs
19-5014; Rev 7; 5/15
EVALUATION KIT AVAILABLE
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
2
TABLE OF CONTENTS
General Description ............................................................................ 1
Applications .................................................................................. 1
Benefits and Features .......................................................................... 1
Absolute Maximum Ratings ...................................................................... 6
Package Thermal Characteristics (Note 1) .......................................................... 6
DC Electrical Characteristics ..................................................................... 6
AC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Test Circuits/Timing Diagrams ................................................................... 10
Typical Operating Characteristics .................................................................11
Pin Configurations ............................................................................ 12
Pin Descriptions .............................................................................. 12
Register Map ................................................................................ 14
Detailed Description........................................................................... 15
Register Set................................................................................15
Receive and Transmit FIFOs ..................................................................15
Transmitter Operation ........................................................................15
Receiver Operation ..........................................................................16
Line Noise Indication.........................................................................16
Clocking and Baud-Rate Generation ............................................................16
Crystal Oscillator .........................................................................17
External Clock Source .....................................................................17
PLL and Predivider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fractional Baud-Rate Generator................................................................17
2x and 4x Rate Modes .......................................................................18
Multidrop Mode ..........................................................................19
Auto Data Filtering in Multidrop Mode .........................................................19
Auto Transceiver Direction Control..............................................................19
Echo Suppression ...........................................................................20
Auto Hardware Flow Control...................................................................20
AutoRTS Control .........................................................................20
AutoCTS Control .........................................................................21
Auto Software (XON/XOFF) Flow Control ........................................................21
Transmitter Flow Control ...................................................................22
Receiver Flow Control .....................................................................22
FIFO Interrupt Triggering .....................................................................22
Low-Power Standby Modes ...................................................................22
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
3
Forced Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Autosleep Mode ..........................................................................22
Shutdown Mode ..........................................................................22
Power-Up and IRQ................................................................22
Interrupt Structure ...........................................................................23
Interrupt Enabling.........................................................................23
Interrupt Clearing .........................................................................23
Detailed Register Descriptions .................................................................23
Serial Controller Interface ...................................................................... 44
SPI Interface ...............................................................................44
SPI Single-Cycle Access ...................................................................44
SPI Burst Access .........................................................................44
I2C Interface ...............................................................................44
START, STOP, and Repeated START Conditions................................................45
Slave Address ...........................................................................45
Bit Transfer..............................................................................45
Single-Byte Write .........................................................................45
Burst Write ..............................................................................45
Single-Byte Read.........................................................................46
Burst Read ..............................................................................47
Acknowledge ............................................................................47
Applications Information........................................................................ 47
Startup and Initialization ......................................................................47
Low-Power Operation ........................................................................48
Interrupts and Polling ........................................................................48
Logic-Level Translation .......................................................................48
Connector Pin Sharing .......................................................................49
RS-232 5x3 Application ......................................................................49
Typical Application Circuit ...................................................................... 49
Chip Information .............................................................................. 49
Ordering Information .......................................................................... 49
Functional Diagram ........................................................................... 51
Package Information .......................................................................... 51
Revision History .............................................................................. 52
TABLE OF CONTENTS (CONTINUED)
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
4
LIST OF TABLES
Table 1. StopBits Truth Table .................................................................... 33
Table 2. Length[1:0] Truth Table.................................................................. 33
Table 3. SwFlow[3:0] Truth Table................................................................. 38
Table 4. PLLFactor[1:0] Selection Guide ............................................................41
Table 5. I2C Address Map ...................................................................... 45
LIST OF FIGURES
Figure 1. I2C Timing Diagram ................................................................... 10
Figure 2. SPI Timing Diagram ................................................................... 10
Figure 3. Transmit FIFO Signals ................................................................. 15
Figure 4. Receive Data Format .................................................................. 16
Figure 5. Midbit Sampling ...................................................................... 16
Figure 6. Receive FIFO ........................................................................ 17
Figure 7. Clock Selection Diagram................................................................ 17
Figure 8. 2x and 4x Baud Rates ................................................................. 18
Figure 9. Auto Transceiver Direction Control........................................................ 19
Figure 10. Setup and Hold Times in Auto Transceiver Direction Control .................................. 20
Figure 11. Half-Duplex with Echo Suppression ...................................................... 20
Figure 12. Echo Suppression Timing.............................................................. 21
Figure 13. Simplified Interrupt Structure ........................................................... 23
Figure 14. PLL Signal Path ......................................................................41
Figure 15. SPI Single-Cycle Read ................................................................ 44
Figure 16. SPI Single-Cycle Write ................................................................ 44
Figure 17. I2C START, STOP, and Repeated START Conditions ........................................ 45
Figure 18. Write Byte Sequence ................................................................. 46
Figure 19. Burst Write Sequence ................................................................. 46
Figure 20. Read Byte Sequence ................................................................. 46
Figure 21. Burst Read Sequence................................................................. 47
Figure 22. Acknowledge........................................................................ 47
Figure 23. Startup and Initialization Flowchart ...................................................... 48
Figure 24. Logic-Level Translation................................................................ 49
Figure 25. Connector Sharing with a USB Transceiver ................................................ 49
Figure 26. RS-232 Application................................................................... 50
Figure 27. RS-485 Half-Duplex Application......................................................... 50
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
5
LIST OF REGISTERS
RHR—Receiver Hold Register................................................................... 23
THRTransmit Hold Register ................................................................... 24
IRQEnIRQ Enable Register ................................................................... 24
ISRInterrupt Status Register .................................................................. 25
LSRIntEnLine Status Register Interrupt Enable.................................................... 26
LSR—Line Status Register ..................................................................... 27
SpclChrIntEn—Special Character Interrupt Enable Register ........................................... 28
SpclCharInt—Special Character Interrupt Register................................................... 29
STSIntEnSTS Interrupt Enable Register ......................................................... 30
STSIntStatus Interrupt Register ................................................................ 30
MODE1 Register ............................................................................. 31
MODE2 Register ............................................................................. 32
LCR—Line Control Register..................................................................... 33
RxTimeOut—Receiver Timeout Register........................................................... 34
HDplxDelay Register .......................................................................... 34
IrDA Register ................................................................................ 35
FlowLvlFlow Level Register ................................................................... 35
FIFOTrgLvlFIFO Interrupt Trigger Level Register ................................................... 36
TxFIFOLvl—Transmit FIFO Level Register.......................................................... 36
RxFIFOLvlReceive FIFO Level Register ......................................................... 36
FlowCtrlFlow Control Register ................................................................. 37
XON1 Register ............................................................................... 38
XON2 Register ............................................................................... 39
XOFF1 Register .............................................................................. 39
XOFF2 Register .............................................................................. 40
GPIOConfg—GPIO Configuration Register......................................................... 40
GPIODataGPIO Data Register................................................................. 40
PLLConfigPLL Configuration Register ............................................................41
BRGConfigBaud-Rate Generator Configuration Register ............................................ 42
DIVLSBBaud-Rate Generator LSB Divisor Register ................................................ 42
DIVMSBBaud-Rate Generator MSB Divisor Register ............................................... 42
CLKSourceClock Source Register .............................................................. 43
RevIDRevision Identification Register ........................................................... 43
TQFN
Junction-to-Ambient Thermal Resistance (θJA).......... 65°C/W
Junction-to-Case Thermal Resistance (θJC) .............. 15°C/W
SSOP
Junction-to-Ambient Thermal Resistance (θJA)...........81°C/W
Junction-to-Case Thermal Resistance (θJC) .............. 32°C/W
(Voltages referenced to AGND.)
VL, VA, VEXT, XIN ............................................... -0.3V to +4.0V
V18, XOUT .................................................. -0.3V to (VA + 0.3V)
RST, IRQ, DIN/A1, CS/A0, SCLK/SCL,
DOUT/SDA, LDOEN, I2C/SPI ................ -0.3V to (VL + 0.3V)
TX, RX, RTS/CLKOUT, CTS, GPIO_ .... -0.3V to (VEXT + 0.3V)
DGND .................................................................. -0.3V to +0.3V
Continuous Power Dissipation (TA = +70°C)
TQFN (derate 15.4mW/°C above +70°C)................. 1229mW
SSOP (derate 12.3mW/°C above +70°C) .................. 988mW
Operating Temperature Range .......................... -40°C to +85°C
Junction Temperature ..................................................... +150°C
Storage Temperature Range ........................... -65°C to +150°C
Lead Temperature (soldering, 10s).................................+300°C
Soldering Temperature (reflow).......................................+260°C
(VA = +2.35V to +3.6V, VL = +1.71V to +3.6V, VEXT = +1.71V to +3.6V, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at VA = +2.8V, VL = +1.8V, VEXT = +2.5V, TA = +25°C.) (Note 2)
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer
board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Digital Interface Supply Voltage VL1.71 3.6 V
Analog Supply Voltage VA2.35 3.6 V
UART Interface Logic Supply
Voltage VEXT 1.71 3.6 V
Logic Supply Voltage V18 1.65 1.80 1.95 V
CURRENT CONSUMPTION
VA Supply Current IA
1.8MHz crystal oscillator active, PLL disabled,
VLDOEN = VL, SPI/I2C interface idle 220 500 µA
Baud rate = 1Mbps, external clock, SPI
frequency is 8MHz, external loopback PLL
disabled, VLDOEN = VL (Note 3)
0.65 1.3 mA
VA Shutdown Supply Current IA, SHDN
Shutdown mode, VLDOEN = 0V, VRST = 0V,
all inputs and outputs are idle 20 35 µA
VA Sleep Supply Current IA, SLEEP
Sleep mode, VLDOEN = VL, VRST = VL, all
inputs and outputs are idle 45 100 µA
VL Supply Current ILAll logic inputs are at VL or VEXT or 0V 4 15 µA
VEXT Supply Current IEXT All logic inputs are at VL or VEXT or 0V 5 10 µA
V18 Input Power-Supply Current
in Shutdown Mode I18SHDN
VLDOEN = 0V (V18 is powered by an
external 1.85V voltage source), static
power consumption
7 50 µA
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
6
DC Electrical Characteristics
Package Thermal Characteristics (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Absolute Maximum Ratings
(VA = +2.35V to +3.6V, VL = +1.71V to +3.6V, VEXT = +1.71V to +3.6V, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at VA = +2.8V, VL = +1.8V, VEXT = +2.5V, TA = +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SCLK/SCL, DOUT/SDA
DOUT/SDA Output Low Voltage
in I2C Mode VOL,I2C
ILOAD = -3mA, VL > 2V 0.4 V
ILOAD = -3mA, VL < 2V 0.2 x VLV
DOUT/SDA Output Low Voltage
in SPI Mode VOL,SPI ILOAD = -2mA 0.4 V
DOUT/SDA Output High Voltage
in SPI Mode VOH,SPI ILOAD = 2mA VL - 0.4 V
Input Low Voltage VIL SPI and I2C mode 0.3 x VLV
Input High Voltage VIH SPI and I2C mode 0.7 x VLV
Input Hysteresis VHYST SPI and I2C mode 0.05 x VLV
Input Leakage Current IIL VIN = 0 to VL, SPI and I2C mode -1 +1 µA
Input Capacitance CIN_I2C_SPI SPI and I2C mode 5 pF
I2C/SPI, CS/A0, DIN/A1 INPUTS
Input Low Voltage VIL SPI and I2C mode 0.3 x VLV
Input High Voltage VIH SPI and I2C mode 0.7 x VLV
Input Hysteresis VHYST SPI and I2C mode 50 mV
Input Leakage Current IIL VIN = 0 to VL, SPI and I2C mode -1 +1 µA
Input Capacitance CIN_I2C_SPI SPI and I2C mode 5 pF
IRQ OUTPUT (OPEN DRAIN)
Output Low Voltage VOL ILOAD = -2mA 0.4 V
Output Leakage ILK VIRQ = 0 to VL, IRQ is not asserted -1 +1 µA
LDOEN AND RST INPUTS
Input Low Voltage VIL 0.3 x VLV
Input High Voltage VIH 0.7 x VLV
Input Hysteresis VHYST 50 mV
Input Leakage Current IIN VIN = 0 to VL-1 +1 µA
RTS/CLKOUT AND TX OUTPUTS
Output Low Voltage VOL ILOAD = -2mA 0.4 V
Output High Voltage VOH ILOAD = 2mA VEXT - 0.4 V
Input Leakage Current IIN Output three-stated, VIN = 0 to VEXT -1 +1 µA
Input Capacitance CIN_IRSTB High-Z mode 5 pF
RX, CTS INPUTS
Input Low Voltage VIL 0.3 x VEXT V
Input High Voltage VIH 0.7 x VEXT V
Input Hysteresis VHYST 50 mV
CTS Input Leakage Current IIN_CTS VIN = 0 to VEXT -1 +1 µA
RX Pullup Current IIN_RX VIN = 0V 0.3 1.5 3 µA
Input Capacitance CIN_IUART 5 pF
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
7
DC Electrical Characteristics (continued)
(VA = +2.35V to +3.6V, VL = +1.71V to +3.6V, VEXT = +1.71V to +3.6V, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at VA = +2.8V, VL = +1.8V, VEXT = +2.5V, TA = +25°C.) (Note 2)
(VA = +2.35V to +3.6V, VL = +1.71V to +3.6V, VEXT = +1.71V to +3.6V, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at VA = +2.8V, VL = +1.8V, VEXT = +2.5V, TA = +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
UART CLOCKING
External Crystal Frequency fXOSC 1 4 MHz
External Clock Frequency fCLK 0.5 35 MHz
External Clock Duty Cycle (Note 3) 45 55 %
Baud-Rate Generator Clock
Input fREF (Note 3) 96 MHz
I2C BUS: TIMING CHARACTERISTICS (see Figure 1)
SCL Clock Frequency fSCL
Standard mode 100 kHz
Fast mode 400
Bus Free Time Between a STOP
(P) and START (S) Condition tBUF
Standard mode 4.7 µs
Fast mode 1.3
Hold Time for START (S)
Condition and Repeated START
(Sr) Condition (Note 3)
tHD:STA
Standard mode 4.0
µs
Fast mode 0.6
Low Period of the SCL Clock tLOW
Standard mode 4.7 µs
Fast mode 1.3
High Period of the SCL Clock tHIGH
Standard mode 4.0 µs
Fast mode 0.6
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
GPIO_ OUTPUTS AND INPUTS
Output Low Voltage VOL ILOAD = -2mA, push-pull or open drain 0.4 V
Output High Voltage VOH ILOAD = 2mA, push-pull VEXT - 0.4 V
Input Low Voltage VIL Congured as an input 0.4 V
Input High Voltage VIH Congured as an input 2/3 x VEXT V
Pulldown Current IPD GPIO_ = VEXT 0.25 1 2.5 µA
Input Capacitance CIN_IUART Congured as an input 5 pF
XIN
Input Low Voltage VIL 0.3 V
Input High Voltage VIH 1.2 VAV
Input Capacitance CXI 16 pF
XOUT
Input Capacitance CXO 16 pF
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
8
AC Electrical Characteristics
DC Electrical Characteristics (continued)
Note 2: All devices are production tested at TA = +25°C. Specifications over temperature are guaranteed by design.
Note 3: Not production tested. Guaranteed by design.
Note 4: When V18 is powered by an external voltage regulator, the external power supply must have current capability above or
equal to I18.
Note 5: CB is the total capacitance of either the clock or data line of the synchronous bus in pF.
(VA = +2.35V to +3.6V, VL = +1.71V to +3.6V, VEXT = +1.71V to +3.6V, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at VA = +2.8V, VL = +1.8V, VEXT = +2.5V, TA = +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Data Hold Time tHD:DAT
Standard mode 0 0.9 µs
Fast mode 0 0.9
Data Setup Time tSU:DAT
Standard mode 250 ns
Fast mode 100
Setup Time for Repeated START
(Sr) Condition tSU:STA
Standard mode 4.7 µs
Fast mode 0.6
Rise Time of SDA and SCL
Signals Receiving tR
Standard mode (0.3 x VL to 0.7 x VL)
(Note 5)
20 +
0.1CB
1000
ns
Fast mode (0.3 x VL to 0.7 x VL) (Note 5) 20 +
0.1CB
300
Fall Time of SDA and SCL
Signals tF
Standard mode (0.7 x VL to 0.3 x VL)
(Note 5)
20 +
0.1CB
300
ns
Fast mode (0.7 x VL to 0.3 x VL) (Note 5) 20 +
0.1CB
300
Setup Time for STOP (P)
Condition tSU:STO
Standard mode 4.7 µs
Fast mode 0.6
Capacitive Load for SDA and
SCL (Note 3) CB
Standard mode 400 pF
Fast mode 400
I/O Capacitance (SCL, SDA) CI/O 10 pF
Pulse Width of Spike
Suppressed tSP 50 ns
SPI BUS: TIMING CHARACTERISTICS (see Figure 2)
SCLK Clock Period tCH+CL 38.4 ns
SCLK Pulse-Width High tCH 16 ns
SCLK Pulse-Width Low tCL 16 ns
CS Fall to SCLK Rise Time tCSS 0 ns
DIN Hold Time tDH 3 ns
DIN Setup Time tDS 5 ns
Output Data Propagation Delay tDO 20 ns
DOUT Rise and Fall Times tFT 10 ns
CS Hold Time tCSH 32 ns
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
9
AC Electrical Characteristics (continued
Figure 2. SPI Timing Diagram
Figure 1. I2C Timing Diagram
CS
SCLK
DIN
DOUT
tCSH
tCSS tCL
tDS
tDH
tCH
tDO
tCSH
SDA
START CONDITION
(S)
START CONDITION
(S)
REPEATED START CONDITION
(Sr)
STOP CONDITION
(P)
SCL
tHD:STA
tSU:DAT tSU:STA
tHD:DAT tHD:STA tSU:STO
tRtF
tBUF
tHIGH tLOW
tRtF
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
10
Test Circuits/Timing Diagrams
(VA = 2.5V, VL = 2.5V, VEXT = 2.5V, LDOEN = VL, TA = +25°C, unless otherwise noted.)
GPIO_ OUTPUT LOW VOLTAGE
vs. SINK CURRENT (OPEN DRAIN)
MAX3107 toc07
VOL (V)
ISINK (mA)
21
5
10
15
20
25
30
35
0
0 3
VEXT = 3.3V
VEXT = 2.5V
GPIO_ OUTPUT HIGH VOLTAGE
vs. SOURCE CURRENT (PUSH-PULL)
MAX3107 toc06
VOH (V)
ISOURCE (mA)
3.02.52.01.51.00.5
5
10
15
20
25
30
35
0
0 3.5
VEXT = 3.3V
VEXT = 2.5V
IA SUPPLY CURRENT
vs. PLL FREQUENCY
MAX3107 toc05
PLL FREQUENCY (MHz)
IA (mA)
2.25
2.50
2.75
3.00
3.25
3.50
3.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
2.00
10 100
PLL = x48
PLL = x96
PLL = x144
IA SUPPLY CURRENT
vs. TEMPERATURE
MAX3107 toc04
TEMPERATURE (°C)
IA (µA)
603510-15
20
40
60
80
100
120
140
0
-40 85
EXTERNAL 3.6MHz CLOCK
BAUD RATE = 115kbps
VA = 3.3V
VA = 2.5V
IA SUPPLY CURRENT vs. VA VOLTAGE
(EXTERNAL CRYSTAL, PLL ENABLED)
MAX3107 toc03
VA (V)
I
A
(mA)
3.353.102.60 2.85
0.925
0.950
0.975
1.000
1.050
1.025
1.075
1.100
0.900
2.35 3.60
3.686MHz EXT. CRYSTAL
BAUD RATE = 115kbps
6x PLL MULT.FACTOR
LDOEN = VL
LDOEN = AGND
1.8V APPLIED TO V18
IA SUPPLY CURRENT vs. VA VOLTAGE
(EXTERNAL CLOCK, PLL ENABLED)
MAX3107 toc02
VA (V)
IA (mA)
3.353.102.852.60
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
2.0
2.35 3.60
EXTERNAL 614kHz CLOCK
BAUD RATE = 115kbps
6x PLL MULT.FACTOR
LDOEN = VL
LDOEN = AGND
1.8V APPLIED TO V18
IA SUPPLY CURRENT vs. VA VOLTAGE
(EXTERNAL CLOCK, PLL DISABLED)
MAX3107 toc01
VA (V)
IA (µA)
3.353.102.852.60
20
40
60
80
100
120
140
0
2.35 3.60
EXTERNAL 3.6MHz CLOCK
BAUD RATE = 115kbps
LDOEN = VL
LDOEN = AGND
1.8V APPLIED TO V18
MAX3107 SPI/I2C UART with 128-Word FIFOs
Maxim Integrated
11
www.maximintegrated.com
Typical Operating Characteristics
PIN NAME FUNCTION
TQFN-EP SSOP
1 4 V18
Internal 1.8V LDO Output and 1.8V Logic Supply Input. Bypass V18 with a 1µF
ceramic capacitor to DGND. Keep V18 powered in shutdown mode.
2 5 I2C/SPI SPI or Active-Low I2C Selector Input. Drive I2C/SPI high to enable SPI. Drive I2C/SPI
low to enable I2C.
3 6 LDOEN
LDO Enable Input. Drive LDOEN high to enable the internal 1.8V LDO. Drive LDOEN
low to disable the internal LDO. Power V18 with an external 1.8V supply when
LDOEN is low.
4 7 DOUT/SDA
Serial-Data Output. When I2C/SPI is high, DOUT/SDA functions as the DOUT SPI
serial-data output. When I2C/SPI is low, DOUT/SDA functions as the SDA I2C serial-
data input/output.
5 8 SCLK/SCL
Serial-Clock Input. When I2C/SPI is high, SCLK/SCL functions as the SCLK SPI serial-
clock input (up to 26MHz). When I2C/SPI is low, SCLK/SCL functions as the SCL I2C
serial-clock input (up to 400kHz).
6 9 CS/A0
Active-Low Chip-Select and Address 0 Input. When I2C/SPI is high, CS/A0 functions
as the CS SPI active-low chip select. When I2C/SPI is low, CS/A0 functions as the A0
I2C device address programming input. Connect CS/A0 to DGND or VL.
TQFN
(3.5mm × 3.5mm)
MAX3107
19
20
21
22
1 2 3 4 5 6
18 17 16 15 14 13
23
24
12
11
10
9
8
7
TX
XOUT
VEXT
XIN
VA+
V18
I2C/SPI
LDOEN
DOUT/SDA
SCLK/SCL
CS/A0
RX
GPIO3
GPIO2
GPIO1
AGND
*EP
*CONNECT EP TO AGND.
GPIO0
VL
DGND
RST
DIN/A1
IRQ
CTS
TOP VIEW
24
23
22
21
20
19
17
1
2
3
4
5
6
8
XOUT
VEXT
TX
RX
V18
VA
AGND
XIN
MAX3107
CTS
GPIO2
SCLK/SCL
LDOEN
18
7GPIO3
DOUT/SDA
15
10 GPIO0
DIN/A1
16
9GPIO1
CS/A0
13
12 VL
RST
14
11 DGND
IRQ
I2C/SPI
SSOP
+
RTS/CLKOUT
RTS/CLKOUT
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
12
Pin Descriptions
Pin Congurations
PIN NAME FUNCTION
TQFN-EP SSOP
7 10 DIN/A1
Serial-Data and Address 1 Input. When I2C/SPI is high, DIN/A1 functions as the DIN
SPI serial-data input. When I2C/SPI is low, DIN/A1 functions as the A1 I2C device
address programming input and connects to DIN/A1 DGND or VL.
811 IRQ Active-Low Interrupt Open-Drain Output. IRQ is asserted when an interrupt is pending.
9 12 RST
Active-Low Reset Input. Drive RST low to force the UART into hardware reset mode.
In hardware reset mode, the oscillator and the internal PLL are shut down; there is no
clock activity.
10 13 VL
Digital Interface Logic-Level Supply. VL powers the internal logic-level translators for
RST, IRQ, DIN/A1, CS/A0, SCLK/SCL, DOUT/SDA, LDOEN, and I2C/SPI. Bypass VL
with a 0.1µF ceramic capacitor to DGND. VL must be powered in all modes.
11 14 DGND Digital Ground
12 15 GPIO0 General-Purpose Input/Output 0. GPIO0 is user programmable as an input or output
(push-pull or open drain). GPIO0 has a weak pulldown resistor to ground.
13 16 GPIO1 General-Purpose Input/Output 1. GPIO1 is user programmable as an input or output
(push-pull or open drain). GPIO1 has a weak pulldown resistor to ground.
14 17 GPIO2 General-Purpose Input/Output 2. GPIO2 is user programmable as an input or output
(push-pull or open drain). GPIO2 has a weak pulldown resistor to ground.
15 18 GPIO3 General-Purpose Input/Output 3. GPIO3 is user programmable as an input or output
(push-pull or open drain). GPIO3 has a weak pulldown resistor to ground.
16 19 CTS Active-Low Clear-to-Send Input. CTS is a ow-control input.
17 20 RTS/CLKOUT Active-Low Request-to-Send Output. RTS/CLKOUT can be set high or low by
programming bit 7 (RTS) of the LCR register.
18 21 RX Receive Input. Serial UART data input. RX has an internal weak pullup resistor to VEXT.
19 22 TX Transmit Output. Serial UART data output.
20 23 VEXT
Transceiver Interface Level Supply. VEXT powers the internal logic-level translators
for RX, TX, RTS, CTS, and GPIO_. Bypass VEXT with a 0.1µF ceramic capacitor to
DGND.
21 24 XOUT
Crystal Output. When using an external crystal, connect one end of the crystal to
XOUT and the other to XIN. When using an external clock source, leave XOUT
unconnected.
22 1 XIN
Crystal/Clock Input. When using an external crystal, connect one end of the crystal to
XIN and the other one to XOUT. When using an external clock source, drive XIN with
the external clock.
23 2 AGND Analog Ground
24 3 VA
Analog Supply. VA powers the PLL and internal LDO. Bypass VA with a 0.1µF ceramic
capacitor to AGND.
EP Exposed Paddle. Connect EP to AGND. EP is not intended as an electrical connection
point. Only for TQFN-EP package.
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
13
Pin Descriptions (continued)
*Denotes nonzero default reset value: ISR = 0x60, LCR = 0x05, FIFOTrgLvl = 0xFF, PLLConfig = 0x01, DIVLSB = 0x01,
CLKSource = 0x08, RevID = 0xA1.
†Denotes nonread/write value: RHR = R, THR = W, ISR = COR, SpclCharInt = COR, STSInt = R/COR, LSR = R, TxFIFOLvl = R,
RxFIFOLvl = R, RevID = R.
REGISTER ADDR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
FIFO DATA
RHR†* 0x00 RData7 RData6 RData5 RData4 RData3 RData2 RData1 RData0
THR0x00 TData7 TData6 TData5 TData4 TData3 TData2 TData1 TData0
INTERRUPTS
IRQEn 0x01 CTSIEn RxEmtyIEn TxEmtyIEn TxTrgIEn RxTrgIEn STSIEn SpclChrIEn LSRErrIEn
ISR*† 0x02 CTSInt RxEmptyInt TxEmptyInt TFifoTriglnt RFifoTrigInt STSInt SpCharInt LSRErrInt
LSRIntEn 0x03 NoiseIntEn RBreakIEn FrameErrIEn ParityIEn ROverrIEn RTimoutIEn
LSR*† 0x04 CTSbit RxNoise RxBreak FrameErr RxParityErr RxOverrun RTimeout
SpclChrIntEn 0x05 MltDrpIntEn BREAKIntEn XOFF2IntEn XOFF1IntEn XON2IntEn XON1IntEn
SpclCharInt 0x06 MultiDropInt BREAKInt XOFF2Int XOFF1Int XON2Int XON1Int
STSIntEn 0x07 SleepIntEn ClkRdyIntEn GPI3IntEn GPI2IntEn GPI1IntEn GPI0IntEn
STSInt*† 0x08 SleepInt ClockReady GPI3Int GPI2Int GPI1Int GPI0Int
UART MODES
MODE1 0x09 IRQSel AutoSleep ForcedSleep TrnscvCtrl RTSHiZ TXHiZ TxDisabl RxDisabl
MODE2 0x0A EchoSuprs MultiDrop Loopback SpecialChr RxEmtyInv RxTrigInv FIFORst RST
LCR*0x0B RTS TxBreak ForceParity EvenParity ParityEn StopBits Length1 Length0
RxTimeOut 0x0C TimOut7 TimOut6 TimOut5 TimOut4 TimOut3 TimOut2 TimOut1 TimOut0
HDplxDelay 0x0D Setup3 Setup2 Setup1 Setup0 Hold3 Hold2 Hold1 Hold0
IrDA 0x0E TxInv RxInv MIR SIR IrDAEn
FIFO CONTROL
FlowLvl 0x0F Resume3 Resume2 Resume1 Resume0 Halt3 Halt2 Halt1 Halt0
FIFOTrgLvl*0x10 RxTrig3 RxTrig2 RxTrig1 RxTrig0 TxTrig3 TxTrig2 TxTrig1 TxTrig0
TxFIFOLvl0x11 TxFL7 TxFL6 TxFL5 TxFL4 TxFL3 TxFL2 TxFL1 TxFL0
RxFIFOLvl0x12 RxFL7 RxFL6 RxFL5 RxFL4 RxFL3 RxFL2 RxFL1 RxFL0
FLOW CONTROL
FlowCtrl 0x13 SwFlow3 SwFlow2 SwFlow1 SwFlow0 SwFlowEn GPIAddr AutoCTS AutoRTS
XON1 0x14 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
XON2 0x15 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
XOFF1 0x16 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
XOFF2 0x17 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
GPIOs
GPIOConfg 0x18 GP3OD GP2OD GP1OD GP0OD GP3Out GP2Out GP1Out GP0Out
GPIOData 0x19 GPI3Dat GPI2Dat GPI1Dat GPI0Dat GPO3Dat GPO2Dat GPO1Dat GPO0Dat
CLOCK CONFIGURATION
PLLCong* 0x1A PLLFactor1 PLLFactor0 PreDiv5 PreDiv4 PreDiv3 PreDiv2 PreDiv1 PreDiv0
BRGCong 0x1B 4xMode 2xMode FRACT3 FRACT2 FRACT1 FRACT0
DIVLSB 0x1C Div7 Div6 Div5 Div4 Div3 Div2 Div1 Div0
DIVMSB 0x1D Div15 Div14 Div13 Div12 Div11 Div10 Div9 Div8
CLKSource*0x1E CLKtoRTS —- ClockEn PLLBypass PLLEn CrystalEn
REVISION
RevID*† 0x1F 1 0 1 0 0 0 0 1
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
14
Register Map
(All default reset values are 0x00, unless otherwise noted. All registers are R/W, unless otherwise noted.)
MICROWIRE is a registered trademark of National
Semiconductor Corp.
Detailed Description
The MAX3107 UART is a bridge between an SPI/
MICROWIRE® or I2C microprocessor bus and an
asynchronous serial-data communication link, such as
RS-485, RS-232, or IrDA. The MAX3107 contains an
advanced UART, a fractional baud-rate generator, and
four GPIOs. The MAX3107 is configured and monitored,
and data is written and read from 8-bit registers through
SPI or I2C. These registers are organized by related
function as shown in the Register Map.
The host controller loads data into the Transmit Holding
register (THR) through SPI or I2C. This data is automati-
cally pushed into the transmit FIFO and sent out at TX.
The MAX3107 adds START, STOP, and parity bits to the
data and sends the data out at the selected baud rate.
The clock configuration registers determine the baud rate,
clock source selection, and clock frequency prescaling.
The receiver in the MAX3107 detects a START bit as a
high-to-low RX transition. An internal clock samples this
data. The received data is automatically placed in the
receive FIFO and can then be read out of the RxFIFO
through the RHR.
Register Set
The MAX3107 has a flat register structure without shadow
registers. The registers are 8 bits wide. The MAX3107
registers have some similarities to the 16C550 registers.
Receive and Transmit FIFOs
The UART’s receiver and the transmitter each have a
128-word deep FIFO, reducing the intervals that the host
processor needs to dedicate for high-speed, high-volume
data transfer. As the data rates of the asynchronous RX,
TX interfaces increase and get closer to those of the host
controller’s SPI/I2C data rates, UART management and
flow control can make up a significant portion of the host’s
activity. By increasing FIFO size, the host is interrupted
less often and can utilize SPI/I2C burst data block
transfers to/from the FIFOs.
FIFO trigger levels can generate interrupts to the host
controller, signaling that programmed FIFO fill levels
have been reached. The transmitter and receiver trig-
ger levels are programmed through FIFOTrgLvl with a
resolution of eight FIFO locations. When a receive FIFO
trigger is generated, the host knows that the receive
FIFO has a defined number of words waiting to be read
out or that a known number of vacant FIFO locations are
available and ready to be filled. The transmit FIFO trigger
generates an interrupt when the transmit FIFO level is
above the programmed trigger level. The host then knows
to throttle data writing to the transmit FIFO.
The host can read out the number of words present in each
of the FIFOs through the TxFIFOLvl and RxFIFOLvl regis-
ters. Note: The TxFIFOLvl and RxFIFOLvl values can be
in error. See the TxFIFOLvl register description for details.
Transmitter Operation
Figure 3 shows the structure of the transmitter with the
TxFIFO. The transmit FIFO can hold up to 128 words that
are written to it through THR.
The transmit FIFO can be programmed to generate
an interrupt when a programmed number of words are
present in the TxFIFO through the FIFOTrgLvl register.
The TxFIFO interrupt trigger level is selectable through
FIFOTrgLvl[3:0]. When the transmit FIFO fill level reaches
the programmed trigger level, the ISR[4] interrupt is set.
The transmit FIFO is empty when ISR[5]: TxEmtyInt is set.
ISR[5] turns high when the transmitter starts transmit-
ting the last word in the TxFIFO. Hence, the transmitter
is completely empty after ISR[5] is set with an additional
delay equal to the length of a complete character (includ-
ing START, parity, and STOP bits).
The contents of the TxFIFO and RxFIFOs are both
cleared through MODE2[1]: FIFORst. To halt transmis-
sion, set MODE1[1]: TxDisabl to 1. After MODE1[1] is
set, the transmitter completes transmission of the current
Figure 3. Transmit FIFO Signals
CURRENT FILL LEVEL
TRANSMITTER TX
TRANSMIT FIFO
FIFOTrgLvl[3:0]
TRIGGER
ISR[4]
THR
DATA FROM SPI/I2C INTERFACE
128
3
2
1
LEVEL
TxFIFOLvl
EMPTY
ISR[5]
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
15
character and then ceases transmission. The TX output
logic can be inverted through IrDA[5]: TxInv. If not stated
otherwise, all transmitter logic described in this data sheet
assumes IrDA[5] is 0. Note: Errors in transmitted data can
occur when the THR is being written to while the transmitter
is sending data. See the THR register description for details.
Receiver Operation
The receiver expects the format of the data at RX to be
as shown in Figure 4. The quiescent logic state is a high
and the first bit (the START bit) is logic-low. The receiver
samples the data near the midbit instant (Figure 4). The
received words and their associated errors are deposited
into the receive FIFO. Errors and status information are
stored for every received word (Figure 6). The host reads
data out of the receive FIFO through the Receive Holding
register (RHR), oldest data first. The status information
of the word previously read out of the RHR is located in
the Line Status register (LSR). After a word is read out of
the RHR, the LSR contains the status information for that
word. Note: If data is read out of RHR simultaneously
when the receiver is receiving data, errors can occur. See
the RHR register description for details.
The following three error conditions are determined for
each received word: parity error, framing error, and noise
on the line. Line noise is detected by checking the con-
sistency of the logic of the three samples (Figure 5). The
receiver can be turned off through MODE1[0]: RxDisabl.
When this bit is set to 1, the MAX3107 turns the receiver
off immediately following the current word and does
not receive any further data. The RX input logic can be
inverted through IrDA[4]: RxInv.
Line Noise Indication
When operating in standard (i.e., not 2x or 4x rate) mode,
the MAX3107 checks that the binary logic level of the
three samples per received bit are identical. If any of the
three samples have differing logic levels, then noise on the
transmission line has affected the received data and is con-
sidered to be noisy. This noise indication is reflected in the
LSR[5]: RxNoise bit for each received byte. Parity errors
are another indication of noise, but are not as sensitive.
Clocking and Baud-Rate Generation
The MAX3107 can be clocked by an external crystal or an
external clock source. Figure 7 shows a simplified diagram
of the clocking circuitry. When the MAX3107 is clocked by
the crystal, the STSInt[5]: ClockReady indicates when the
clocks have settled and the baud-rate generator is ready
for stable operation.
The baud-rate clock can be routed to the RTS/CLKOUT
output. The clock rate is 16x the baud rate in standard
operating mode, and 8x the baud rate in 2x rate mode. In 4x
rate mode, the CLKOUT frequency is 4x the programmed
baud rate. If the fractional portion of the baud-rate genera-
tor is used, the clock is not regular and exhibits jitter.
Figure 5. Midbit Sampling
Figure 4. Receive Data Format
1
RX
BAUD
BLOCK 2 3 4 5 6 7 8 9
ONE BIT PERIOD
10 11
MAJORITY
CENTER
SAMPLER
12 13 14 15 16
A
RECEIVED DATA
LSB
START D0 D1 D2 D3 D4 D5 D6 D7 PARITY STOP STOP
MSB
MIDBIT
SAMPLING
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
16
Crystal Oscillator
Set CLKSource[4]: ClockEn to 1 and CLKSource[1]:
CrystalEn to 1 to enable and select the crystal oscillator.
The on-chip crystal oscillator has load capacitances of
20pF integrated in both XIN and XOUT. Connect an exter-
nal crystal or ceramic oscillator between XIN and XOUT.
External Clock Source
When an external clock signal is used, this should
be connected to XIN. Leave XOUT unconnected.
Set CLKSource[4]: ClockEn to 1 and CLKSource[1]:
CrystalEn to 0 to select external clocking.
PLL and Predivider
The internal predivider and PLL allow for a wide range
of external clock frequencies and baud rates. The PLL
can be configured to multiply the input clock rate by a
factor of 6, 48, 96, or 144 through PLLConfig[7:6]. The
predivider, located between the input clock and the PLL,
allows division of the input clock by a factor between 1
and 63 by writing to PLLConfig[5:0]. See the PLLConfig
register description for more information.
Fractional Baud-Rate Generator
The internal fractional baud-rate generator provides a
high degree of flexibility and high resolution in baud-
rate programming. The baud-rate generator has a 16-bit
integer divisor and a 4-bit word for the fractional divisor.
The fractional baud-rate generator can be used with the
external crystal or clock source.
The integer and fractional divisors are calculated through
the divisor, D:
REF
f
D
16 BaudRate
=
×
where fREF is the reference frequency input to the baud-
rate generator and D is the ideal divisor. fREF must be
less than 96MHz. In 2x and 4x rate modes, replace the
divisor 16 by 8 or 4, respectively.
The integer divisor portion, DIV, of the divisor, D, is
obtained by truncating D:
DIV = TRUNC(D)
Figure 7. Clock Selection Diagram
Figure 6. Receive FIFO
CRYSTAL
OSCILLATOR
XOUT
CrystalEn
XIN
BAUD-RATE
GENERATOR
ClockEn PLLByps
PLLEn
PLLDIVIDER
RECEIVE FIFO
FIFOTrgLvl[7:4]
TRIGGER
ISR[3]
WORD ERROR 128
RxFIFOLvl
4
3
2
1
TIMEOUT
EMPTY
ERRORS
OVERRUN
LSR[1]
RECEIVED
DATA
RHR
RECEIVER RX
I2C/SPI INTERFACE
LSR[0]
ISR[6]
LSR[5:2]
CURRENT FILL LEVEL
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
17
DIV can be a maximum of 16 bits wide and is programmed
into the 2-byte-wide registers DIVMSB and DIVLSB. The
minimum allowed for DIVLSB is 1.
The fractional portion of the divisor, FRACT, is a 4-bit
nibble, which is programmed into BRGConfig[3:0]. The
maximum value is 15, allowing the divisor to be pro-
grammed with a resolution of 0.0625. FRACT is calcu-
lated as:
FRACT = ROUND(16 x (D-DIV))
The following is an example of calculating the divisor.
It is based on a required baud rate of 190kbaud and a
reference input frequency of 28.23MHz and 1x (default)
rate mode.
The ideal divisor is calculated as:
D = 28,230,000/(16 x 190,000)
= 9.2861842105263157894736842105263
hence DIV = 9.
FRACT =
ROUND(4.5789473684210526315789473684211) = 5
so that DIVMSB = 0x00, DIVLSB = 0x09, and
BRGConfig[3:0] = 0x05.
The resulting (actual) baud rate can be calculated as:
REF
ACTUAL
ACTUAL
f
BR 16 D
=
×
For this example: DACTUAL = 9 + 5/16 = 9.3125
where:
DACTUAL = DIV + FRACT/16
and:
BRACTUAL= 28,230,000/(16 x 9.3125)
= 189463.0872483221476510067114094 baud
Thus, the baud rate is within 0.28% of the ideal rate.
2x and 4x Rate Modes
To support higher baud rates than possible with standard
(16x sampling) operation, the MAX3107 offers 2x and 4x
rate modes. In this case, the reference clock rate only
needs to be either 8x or 4x of the baud rate, respec-
tively. The bits are only sampled once at the midbit instant
instead of the usual three samples to determine the logic
value of the bits. This reduces the tolerance to line noise
on the received data. The 2x and 4x modes are selectable
through BRGConfig[5:4]. Note that IrDA encoding and
decoding does not operate in 2x and 4x modes.
When 2x rate mode is selected, the actual baud rate
is twice the rate programmed into the baud-rate gen-
erator. If 4x rate mode is enabled, the actual baud rate
on the line is quadruple that of programmed baud rate
(Figure 8).
Figure 8. 2x and 4x Baud Rates
FRACTIONAL
RATE
GENERATOR
fREF BAUD RATE
BaudRateConfig[5:4]
DIV[LSB]
DIV[MSB]
NOTE: IrDA DOES NOT WORK IN 2x AND 4x MODES.
FRACT
1x, 2x, 4x RATE
MODES
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
18
Multidrop Mode
In multidrop mode, also known as 9-bit mode, the word
length is 8 bits and a 9th bit is used for distinguishing
between an address and a data word. Multidrop mode is
enabled through MODE2[6]: MultiDrop. Parity checking is
disabled and an SpclCharInt[5]: MultiDropInt interrupt is
generated when an address (9th bit set) is received.
It is up to the host processor to filter out the data intended
for its address. Alternatively, the auto data-filtering mode
can be used to automatically filter out the data intended
for the station’s specific 9-bit mode address.
Auto Data Filtering in Multidrop Mode
In multidrop mode, the MAX3107 can be configured
to automatically filter out data that is not meant for its
address. The address is user-definable either by pro-
gramming a register value or a combination of a register
values and GPIO hardware inputs. Use either XOFF2
or XOFF2[7:4] in combination with GPIO_ to define the
address.
Enable multidrop mode by setting MODE2[6]: MultiDrop
to 1 and enable auto data filtering by setting MODE2[4]:
SpecialChr to 1.
When using register bits in combination with GPIO_ to
define the address, the MSB of the address is written to
XOFF2[7:4] register bits, while the LSBs of the address
are defined through the GPIOs. To enable this mode,
set FlowCtrl[2]: GPIAddr, MODE2[4]: SpecialChr, and
MODE2[6]: MultiDrop to 1. GPIO_ is automatically read
when FlowCtrl[2]: GPIAddr is set to 1, and the address is
updated on logic changes at GPIO_.
In the auto data-filtering mode, the MAX3107 auto-
matically accepts data that is meant for its address and
places this into the receive FIFO, while it discards data
that is not meant for its address. The received address
word is not put into the FIFO.
Auto Transceiver Direction Control
In some half-duplex communication systems, the trans-
ceiver’s transmitter must be turned off when data is being
received so as not to load the bus. This is the case in half-
duplex RS-485 communication. Similarly in full-duplex
multidrop communication, like RS-485 or RS-422/V.11,
only one transmitter can be enabled at any one time and
the others must be disabled. The MAX3107 can auto-
matically enable/disable a transceiver’s transmitter and/
or receiver. This relieves the host processor of this time-
critical task.
The RTS/CLKOUT output is used to control the transceiv-
ers’ transmit enable input and is automatically set high
when the MAX3107’s transmitter starts transmission. This
occurs as soon as data is present in the transmit FIFO.
Auto transceiver direction control is enabled through
MODE1[4]: TrnscvCtrl. Figure 9 shows a typical MAX3107
connection in a RS-485 application.
The RTS/CLKOUT output can be set high in advance
of TX transmission by a programmable time period
called the setup time (Figure 10). The setup time is pro-
grammed through HDplxDelay[7:4]. Similarly, the RTS/
CLKOUT signal can be held high for a programmable
period after the transmitter has completed transmission.
The hold time is programmed through HDplxDelay[3:0].
Figure 9. Auto Transceiver Direction Control
MAX3107 MAX13431
TRANSMITTER TX
B
A
D
RTS/CLKOUT
RX
TxFIFO
RECEIVER
AUTO
TRANSCEIVER
CONTROL
RxFIFO
DI
RO
RE
DE
R
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
19
Echo Suppression
The MAX3107 can suppress echoed data, sometimes
found in half-duplex communication (e.g., RS-485 and
IrDA). If the transceiver’s receiver is not turned off
while the transceiver is transmitting, copies (echoes) are
received by the UART. The MAX3107’s receiver can block
the reception of this echoed data by enabling echo sup-
pression. Set MODE2[7]: EchoSuprs to 1 to enable echo
suppression.
The MAX3107 receiver can block echoes with a long
round trip delay. The transmitter can be configured
to remain enabled after the end of transmission for a
programmable period of time: the hold time delay. The
hold time delay is set by the HDplxDelay[3:0] register.
See the HDplxDelay description in the Detailed Register
Descriptions section for more information.
Auto transceiver direction control and echo suppression
can operate simultaneously.
Auto Hardware Flow Control
The MAX3107 is capable of auto hardware (RTS and
CTS) flow control without the need for host processor
intervention. When AutoRTS control is enabled, the
MAX3107 automatically controls the RTS handshake
without the need for host processor intervention. AutoCTS
flow control separately turns the MAX3107’s transmit-
ter on and off based on the CTS input. AutoRTS and
AutoCTS flow control are independently enabled through
FlowCtrl[1:0].
AutoRTS Control
AutoRTS flow control ensures that the receive FIFO does
not overflow by signaling to the far-end UART to stop
data transmission. The MAX3107 does this automati-
cally by controlling RTS/CLKOUT. AutoRTS flow control
is enabled through FlowCtrl[0]: AutoRTS. The HALT and
RESUME levels determine the threshold levels at which
RTS/CLKOUT is asserted and deasserted. HALT and
Figure 11. Half-Duplex with Echo Suppression
Figure 10. Setup and Hold Times in Auto Transceiver Direction Control
MAX3107 MAX13431
TRANSMITTER TX
B
A
D
RX
TxFIFO
RECEIVER
ECHO
SUPPRESSION
RxFIFO
DI
RO
RE
DE
R
RTS/CLKOUT
TX
FIRST CHARACTER LAST CHARACTER
RTS/CLKOUT
SETUP
HOLD
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
20
RESUME are programmed in FlowLvl. With differing
HALT and RESUME levels, hysteresis can be defined for
the RTS/CLKOUT transitions.
When the RxFIFO fill level reaches the HALT level
(FlowLvl[3:0]), the MAX3107 deasserts RTS/CLKOUT.
RTS/CLKOUT remains deasserted until the RxFIFO is
emptied and the number of words falls to the RESUME
level.
Interrupts are not generated when the HALT and
RESUME levels are reached. This allows the host con-
troller to be completely disengaged from RTS flow control
management.
AutoCTS Control
When AutoCTS flow control is enabled, the UART auto-
matically starts transmitting data when the CTS input is
logic-level low and stops transmitting when CTS is logic-
high. This frees the host processor from managing this
timing-critical flow-control task. AutoCTS flow control is
enabled through FlowCtrl[1]: AutoCTS. During AutoCTS
flow control the CTS interrupt works normally. Set the
IRQEn[7]: CTSIntEn to 0 to disable CTS interrupts; then
ISR[7]: CTSInt is fixed to logic 0 and the host does not
receive interrupts from CTS. If CTS is set high during
transmission, the MAX3107 completes transmission of
the current word and halts transmission afterwards.
Turn the transmitter off by setting MODE1[1] to 1 before
enabling AutoCTS control.
Auto Software (XON/XOFF) Flow Control
When auto software flow control is enabled, the MAX3107
recognizes and/or sends predefined XON/XOFF charac-
ters to control the flow of data across the asynchronous
serial link. Auto flow works autonomously and does not
involve host intervention, similar to auto hardware flow
control. To reduce the chance of receiving corrupted
data that equals a single-byte XON or XOFF character,
the MAX3107 allows for double-wide (16-bit) XON/XOFF
characters. XON and XOFF are programmed into the
XON1, XON2 and XOFF1, XOFF2 registers.
FlowCtrl[7:3] are used for enabling and configuring
auto software flow control. An ISR[1] interrupt is gener-
ated when XON or XOFF are received and details are
found in SpclCharInt. The IRQ can be masked by setting
IRQEn[1]: SpclChrIEn to 0.
Software flow control consists of transmitter control and
receiver overflow control, which can operate indepen-
dently of each other.
Figure 12. Echo Suppression Timing
TX
RX
DI TO RO PROPAGATION DELAY
HOLD DELAYSTOP
BIT
RTS/CLKOUT
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
21
Transmitter Flow Control
If auto transmitter control (FlowCtrl[5:4]) is enabled, the
receiver compares all received words with the XOFF and
XON characters. If a XOFF is received, the MAX3107
halts its transmitter from sending further data. The
receiver is not affected and continues reception. Upon
receiving an XON, the transmitter restarts sending data.
The received XON and XOFF characters are filtered out
and are not put into the receive FIFO, as they do not have
significance to the higher layer protocol. An interrupt is not
generated.
Turn the transmitter off (MODE1[1]) before enabling trans-
mitter control.
Receiver Flow Control
If auto receiver overflow control (FlowCtrl[7:6]) is enabled,
the MAX3107 automatically sends XOFF and XON con-
trol characters to the far-end UART to avoid receiver
overflow. XOFF1/XOFF2 are sent when the receive FIFO
fill level reaches the HALT value set in the FlowLvl regis-
ter. When the host controller reads data from the Receive
FIFO to a level equal to the RESUME level programmed
into the FlowLvl register, XON1/XON2 are automati-
cally sent to the far-end station to signal it to resume data
transmission.
If dual-character (XON1 and XON2/XOFF1 and XOFF2)
flow control is selected, XON1/XOFF1 are transmitted
before XON2/XOFF2.
FIFO Interrupt Triggering
Receive and transmit FIFO fill-dependent interrupts are
generated if FIFO trigger levels are defined. When the
number of words in the FIFOs reach or exceed a trigger
level, as programmed in FIFOTrgLvl, an ISR[3] or ISR[4]
interrupt is generated. There is no relationship between
the trigger levels and the HALT or RESUME levels.
The FIFO trigger level can, for example, be used for a
block data transfer, since it gives the host an indication
when a given block size of data is available for readout in
the receive FIFO or available for transfer to the transmit
FIFO.
Low-Power Standby Modes
The sleep and shutdown modes reduce power con-
sumption during periods of inactivity. In both sleep and
shutdown modes, the UART disables specific functional
blocks to reduce power consumption.
Forced Sleep Mode
In forced sleep mode, all UART-related on-chip clocking is
stopped. The following are inactive: the crystal oscillator,
the PLL, the predivider, the receiver, and the transmitter.
The SPI/I2C interface and the registers remain active.
Thus, the host controller can access the resisters. To
enter sleep mode, set MODE1[5] to 1. To wake up, set
MODE1[5] to 0.
Autosleep Mode
The MAX3107 can be configured to operate in autosleep
mode by setting MODE1[6] to 1. In autosleep mode, the
MAX3107 automatically enters sleep mode when all the
following conditions are met:
Both FIFOs are empty.
There are no pending IRQ interrupts.
There is no activity on any input pins for a period
equal to 65,536 UART characters lengths.
The MAX3107 exits autosleep mode as soon as activity is
detected on any of the GPIO_, RX, or CTS inputs.
To manually wake up the MAX3107, set MODE1[6] to
0. After wake-up is initiated, the internal clock starts up
and a period of time is needed for clock stabilization. The
STSInt[5]: ClockReady bit indicates when the clocks are
stable. If an external clock source is used, the STSInt[5]
bit does not indicate clock stability.
Shutdown Mode
Shutdown mode is the lowest power consumption mode.
In shutdown mode, all the MAX3107 circuitry is off. This
includes the I2C/SPI interface, the registers, the FIFOs,
and clocking circuitry. The LDO is kept on. To enter shut-
down mode, connect RST to DGND.
When the RST input is toggled high, the MAX3107 exits
shutdown mode. When the MAX3107 sets IRQ to logic-
high, the chip initialization is completed. The MAX3107
needs to be reprogrammed following a shutdown. Keep
V18 powered by the internal LDO or an external 1.8V
supply during shutdown.
Power-Up and IRQ
IRQ has two functions. During normal operation (MODE1[7]
is 1), IRQ operates as a hardware interrupt output, where-
by the IRQ is active when an interrupt is pending. An IRQ
interrupt is only produced during normal operation, if at
least one of the IRQEn interrupt enable bits are enabled.
During power-up or following a reset, IRQ has a differ-
ent function. It is held low until the MAX3107 is ready for
programming following an initialization delay. Once IRQ
goes high, the MAX3107 is ready to be programmed.
The MODE1[7]: IRQSel bit should then be set in order to
enable normal IRQ interrupt operation.
In polled mode, the RevID register can be polled to
check whether the MAX3107 is ready for operation. If
the controller gets a valid response from RevID, then the
MAX3107 is ready for operation.
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
22
Bits 7–0: RData[7:0]
The RHR is the bottom of the receive FIFO and is the register used for reading data out of the receive FIFO. It contains the oldest
(first received) character in the receive FIFO. RHR[0] is the first data bit of the serial-data word received by the receiver at the RX
pin. Note that the data read out of RHR can be in error. This occurs when the UART receiver is receiving a character at the same
time as a value is being read out of RHR and the FIFO level counter is being updated. In the event of this error condition, the
result is that a character is read out twice from the RHR. To avoid this, the receiver should not be receiving data while the RHR
is being read out. This can be achieved via flow control, or prior knowledge of the amount of data that is expected to be received.
Bits 7–0: TData[7:0]
Interrupt Structure
The structure of the interrupt is shown in Figure 13. There
are four interrupt source registers: ISR, LSR, STSInt,
and SpclCharInt. The interrupt sources are divided into
top-level and low-level interrupts. The top-level interrupts
typically occur more often and can be read out directly
through the ISR. The low-level interrupts typically occur
less often and their specific source can be read out
through the LSR, STSInt, or SpclChar registers. The three
LSBs of the ISR point to the low-level interrupt registers
that contain the source detail of the interrupt source.
Interrupt Enabling
Every interrupt bit of the four interrupt registers can
be enabled or masked through an associated interrupt
enable register bit. These are the IRQEn, LSRIntEn,
SpclChrIntEn and STSIntEn registers.
Interrupt Clearing
When an ISR interrupt is pending (i.e., any bit in ISR is
set) and the ISR is subsequently read, the ISR bits and
IRQ are cleared. Both the SpclCharInt and the STSInt
registers also are clear on read (COR). The LSR bits are
only cleared when the source of the interrupt is removed,
not when LSR is read.
Detailed Register Descriptions
The MAX3107 has a flat register structure, without shad-
ow registers, that makes programming and code simple
and efficient. All registers are 8 bits wide.
Figure 13. Simplified Interrupt Structure
ADDRESS: 0x00
MODE: R
BIT 7 6 5 4 3 2 1 0
NAME RData7 RData6 RData5 RData4 RData3 RData2 RData1 RData0
RESET X X X X X X X X
76543210
ISR
8
[7] IRQ
POWER-UP DONE
MODE1[7]: IRQSel
[0]
LOW-LEVEL INTERRUPTS
TOP-LEVEL INTERRUPTS
76543210
SpclChrInt
8
76 5 4 3 2 1 0
STSInt
8
76 5 4 3 2 1 0
LSR
8
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
23
RHR—Receiver Hold Register
The THR is the register that the host controller writes data to for subsequent UART transmission. This data is deposited
in the transmit FIFO. THR[0] is the LSB. It is the first data bit of the serial-data word that the transmitter sends out, right
after the START bit. Note that an error can occur in the TxFIFO when a character is written into THR at the same time
as the transmitter is transmitting out data via TX. In the event of this error condition, the result is that the character will
not be transmitted. To avoid this, stop the transmitter when writing data to the THR. This can be done via the TxDisable
bit in the MODE1 register.
The IRQEn is used to enable the IRQ physical interrupt. Any of the eight ISR interrupt sources can be enabled to gener-
ate an IRQ. The IRQEn bits only influence the IRQ output and do not have any effect on the ISR contents or behavior.
Every one of the IRQEn bits operates on an ISR bit.
Bit 7: CTSIEn
The CTSIEn bit enables IRQ interrupt generation when the CTSInt interrupt bit is set in the ISR. Set CTSIEn bit low to
disable IRQ generation from CTSInt.
Bit 6: RxEmtyIEn
The RxEmtyIEn bit enables IRQ interrupt generation when the RxEmtyInt interrupt bit is set in the ISR. Set RxEmtyIEn
bit low to disable IRQ generation from RxEmtyInt.
Bit 5: TxEmtyIEn
The TxEmtyIEn bit enables IRQ interrupt generation when the TxEmptyInt interrupt bit is set in the ISR. Set TxEmtyIEn
bit low to disable IRQ generation from TxEmptyInt.
Bit 4: TxTrgIEn
The TxTrgIEn bit enables IRQ interrupt generation when the TFifoTrigInt interrupt bit is set in the ISR. Set TxTrgIEn bit
low to disable IRQ generation from TFifoTrigInt.
Bit 3: RxTrgIEn
The RxTrgIEn bit enables IRQ interrupt generation when the RFifoTrigInt interrupt bit is set in the ISR. Set RxTrgIEn bit
low to disable IRQ generation from RFifoTrigInt.
Bit 2: STSIEn
The STSIEn bit enables IRQ interrupt generation when the STSInt interrupt bit is set in the ISR. Set STSIEn bit low to
disable IRQ generation from STSInt.
Bit 1: SpclChrlEn
The SpclChrIEn bit enables IRQ interrupt generation when the SpCharInt interrupt bit is set in the ISR. Set SpclChrIEn
bit low to disable IRQ generation from SpCharInt.
Bit 0: LSRErrlEn
ADDRESS: 0x01
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME CTSIEn RxEmtyIEn TxEmtyIEn TxTrgIEn RxTrgIEn STSIEn SpclChrIEn LSRErrIEn
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x00
MODE: W
BIT7654321 0
NAME TData7 TData6 TData5 TData4 TData3 TData2 TData1 TData0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
24
IRQEn—IRQ Enable Register
THR—Transmit Hold Register
The LSRErrIEn bit enables IRQ interrupt generation when the LSRErrInt interrupt bit is set in the ISR[0]. Set LSRErrIEn
low to disable IRQ generation from LSRErrInt.
The ISR provides an overview of all interrupts generated in the MAX3107. These interrupts are cleared on reading the
ISR. When the MAX3107 is operated in polled mode, the ISR can be polled to establish the UART’s status. In interrupt-
driven mode, IRQ interrupts are enabled through the appropriate IRQEn bits. The ISR contents give direct information
on the cause for the interrupt or point to other registers that contain more detailed information.
Bit 7: CTSInt
The CTSInt is set when a logic state transition occurs at the CTS input. This bit is cleared after ISR is read. The current
logic state of the CTS input can be read out through the LSR[7]: CTSbit.
Bit 6: RxEmptyInt
The RxEmptyInt is set when the receive FIFO is empty. This bit is cleared after ISR is read. Its meaning can be inverted
by setting the MODE2[3]: RxEmtyInv bit.
Bit 5: TxEmptyInt
The TxEmptyInt bit is set when the transmit FIFO is empty. This bit is cleared once ISR is read.
Bit 4: TFifoTriglnt
The TFifoTrigInt bit is set when the number of characters in the transmit FIFO is equal to or greater than the transmit
FIFO trigger level defined in FIFOTrgLvl[3:0]. TFifoTrigInt is cleared when the transmit FIFO level falls below the trigger
level or after the ISR is read. It can be used as a warning that the transmit FIFO is nearing overflow.
Bit 3: RFifoTriglnt
The RFifoTrigInt bit is set when the receive FIFO fill level reaches the receive FIFO trigger level, as defined in the
FIFOTrgLvl[7:4]. This can be used as an indication that the receive FIFO is nearing overrun. It can also be used to report
that a known number of words are available which can be read out in one block. The meaning of RFifoTrigInt can be
inverted through MODE2[2]. RFifoTrigInt is cleared when ISR is read.
Bit 2: STSInt
The STSInt bit is set high when any bit in the STSInt register that is enabled through a STSIntEn bit is high. The STSInt
bit is cleared on reading ISR.
Bit 1: SpCharlnt
The SpCharInt bit is set high when a special character is received, a line BREAK is detected, or an address character is
received in multidrop mode. The cause for the SpCharInt interrupt can be read from the SpclCharInt register, if enabled
through the SpclChrIntEn bits. The SpCharInt interrupt is cleared when the ISR is read.
Bit 0: LSRErrlnt
The LSRErrInt bit is set high when any LSR bits, which are enabled through the LSRIntEn, are set. This bit is cleared
after the ISR is read.
ADDRESS: 0x02
MODE: COR
BIT 7 6 5 4 3 2 1 0
NAME CTSInt RxEmptyInt TxEmptyInt TFifoTrigInt RFifoTrigInt STSInt SpCharInt LSRErrInt
RESET 0 1 1 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
25
ISR—Interrupt Status Register
The LSRIntEn allows routing of LSR interrupt bits to the ISR[0].
Bits 7 and 6: No Function
Bit 5: NoiseIntEn
Set the NoiseIntEn bit high to enable routing the RxNoise interrupt to LSR[0]. If NoiseIntEn is set low, RxNoise is not
routed to LSR[0].
Bit 4: RBreaklEn
Set the RBreakIEn bit high to enable routing the RxBreak interrupt to LSR[0]. If RBreakIEn is set low, RxBreak is not
routed to LSR[0].
Bit 3: FrameErrlEn
Set the FrameErrIEn bit high to enable routing the FrameErr interrupt to LSR[0]. If FrameErrIEn is set low, FrameErr is
not routed to LSR[0].
Bit 2: ParitylEn
Set the ParityIEn bit high to enable routing the RxParityErr interrupt to LSR[0]. If ParityIEn is set low, RxParityErr is not
routed to the LSR[0].
Bit 1: ROverrlEN
Set the ROverrIEn bit high to enable routing the RxOverrun interrupt to LSR[0]. If ROverrIEn is set low, RxOverrun is not
routed to LSR[0].
Bit 0: RTimoutlEn
Set the RTimoutIEn bit high to enabled routing the RTimeout interrupt to LSR[0]. If RTimoutIEn is set low, the RTimeout
is not routed to LSR[0].
ADDRESS: 0x03
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME NoiseIntEn RBreakIEn FrameErrIEn ParityIEn ROverrIEn RTimoutIEn
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
26
LSRIntEn—Line Status Register Interrupt Enable
The LSR shows all errors related to the word previously read out of the RxFIFO. The LSR bits are not cleared upon a
read; these bits stay set until the character with errors is read out of the RHR. The LSR also reflects the current state
of the CTS input.
Bit 7: CTSbit
The CTSbit reflects the current logic state of the CTS input. This bit is cleared when the CTS input is low. Following a
power-up or reset, the logic state of the CTS bit depends on the CTS input.
Bit 6: No Function
Bit 5: RxNoise
If noise is detected on the RX input during reception of a character, the RxNoise bit is set for that character. The RxNoise
bit indicates that there was noise on the line while the character most recently read from the RHR was received. The
RxNoise flag can generate an ISR[0] interrupt, if enabled through LSRIntEn[5].
Bit 4: RxBreak
If a line BREAK (RX input low for a period longer than the programmed character duration) is detected, a BREAK
character is put in the RxFIFO and the RxBreak bit is set for this character. A BREAK character is represented by an all-
zeros data character. The RxBreak bit distinguishes a regular character with all zeros from a BREAK character. LSR[4]
corresponds to the character most recently read from the RHR. The RxBreak flag can generate an ISR[0] interrupt, if
enabled through LSRIntEn[4].
Bit 3: FrameErr
The FrameErr bit is set high when the received data frame does not match the expected frame format in length.
FrameErr corresponds to the frame error of the character most recently read from the RHR. A frame error is related to
errors in expected STOP bits.
The FrameErr flag can generate an ISR[0] interrupt, if enabled, through LSRIntEn[3].
Bit 2: RxParityErr
If the parity computed on the character being received does not match the received character’s parity bit, the RxParityErr
bit is set for that character. RxParityErr indicates a parity error for the word most recently read from the RHR.
In 9-bit multidrop mode (MODE2[6] = 1) the receiver does not check parity and the RxParityErr represents the 9th (i.e.,
address or data) bit.
The RxParityErr flag can generate an ISR[0] interrupt, if enabled through LSRIntEn[2].
Bit 1: RxOverrun
If the receive FIFO is full and additional data is received that does not fit into the receive FIFO, the RxOverrun bit is set.
The receive FIFO retains the data in it and discards all new data that does not fit into it. The RxOverrun indication is
cleared after the LSR is read or the RxFIFO level falls below its maximum. The RxOverrun flag can generate an ISR[0]
interrupt, if enabled through LSRIntEn[1].
ADDRESS: 0x04
MODE: R
BIT 7 6 5 4 3 2 1 0
NAME CTSbit RxNoise RxBreak FrameErr RxParityErr RxOverrun RTimeout
RESET X 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
27
LSR—Line Status Register
Bit 0: RTimeout
The RTimeout bit indicates that stale data is present in the receive FIFO. RTimeout is set when the youngest character
resides in the RxFIFO for longer than the period programmed into the RxTimeOut register. The timeout counter restarts
when at least one character is read out of the RxFIFO or a new character is received by the RxFIFO. If the value in
RxTimeOut is zero, RTimeout is disabled. RTimeout is cleared when a word is read out of the RxFIFO or a new word is
received. The RTimeout flag can generate an ISR[0] interrupt, if enabled through LSRIntEn[0].
Bits 7 and 6: No Function
Bit 5: MltDrpIntEn
The MltDrpIntEn bit enables routing the SpclCharInt[5]: MultiDropInt interrupt to ISR[1]. If MltDrpIntEn is set low (default),
the MultiDropInt is not routed to the ISR[1].
Bit 4: BREAKIntEn
The BREAKIntEn bit enables routing the SpclCharInt[4]: BREAKInt interrupt to ISR[1]. If BREAKIntEn is set low (default),
the BREAKInt is not routed to the ISR[1].
Bit 3: XOFF2IntE
The XOFF2IntEn bit enables routing the SpclCharInt[3]: XOFF2Int interrupt to ISR[1]. If XOFF2IntEn is set low (default),
the XOFF2Int is not routed to the ISR[1].
Bit 2: XOFF1IntEn
The XOFF1IntEn bit enables routing the SpclCharInt[2]: XOFF1Int interrupt to ISR[1]. If XOFF1IntEn is set low (default),
the XOFF1Int is not routed to the ISR[1].
Bit 1: XON2IntEn
The XON2IntEn bit enables routing the SpclCharInt[1]: XON2Int interrupt to ISR[1]. If XON2IntEn is set low (default), the
XON2Int is not routed to the ISR[1].
Bit 0: XON1IntEn
The XON1IntEn bit enables routing the SpclCharInt[0]: XON1Int interrupt to ISR[1]. If XON1IntEn is set low (default), the
XON1Int is not routed to the ISR[1].
ADDRESS: 0x05
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME MltDrpIntEn BREAKIntEn XOFF2IntEn XOFF1IntEn XON2IntEn XON1IntEn
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
28
SpclChrIntEn—Special Character Interrupt Enable Register
Bits 7 and 6: No Function
Bit 5: MultiDropInt
The MultiDropInt interrupt is set when the MAX3107 receives an address character in 9-bit multidrop mode (MODE2[6] is
1). This bit is cleared when SpclCharInt is read. The SpclCharInt bit can be routed to ISR[1] by enabling SpclChrIntEn[5].
Bit 4: BREAKInt
The BreakInt interrupt is set when a line BREAK (RX low for longer than one character length) is detected by the receiver.
This bit is cleared after SpclCharInt is read. The BREAKInt interrupt can be routed to ISR[1] by enabling SpclChrIntEn[4].
Bit 3: XOFF2Int
The XOFF2Int interrupt bit is set when an XOFF2 special character is received and special character detection is
enabled, through MODE2[4]. This interrupt is cleared upon reading SpclCharInt. The XOFF2Int interrupt can be routed
to the ISR[1] interrupt bit, if enabled through SpclChrIntEn[3].
Bit 2: XOFF1Int
The XOFF1Int interrupt bit is set when an XOFF1 special character is received and special character detection is
enabled, through MODE2[4]. This interrupt is cleared upon reading SpclCharInt. The XOFF1Int interrupt can be routed
to the ISR[1] interrupt bit, if enabled through SpclChrIntEn[2].
Bit 1: XON2Int
The XON2Int interrupt bit is set when an XON2 special character is received and special character detection is enabled,
through MODE2[4]. This interrupt is cleared upon reading SpclCharInt. The XON2Int interrupt can be routed to the ISR[1]
interrupt bit, if enabled through SpclChrIntEn[1].
Bit 0: XON1Int
The XON1Int interrupt bit is set when an XON1 special character is received and special character detection is enabled,
through MODE2[4]. This interrupt is cleared upon reading SpclCharInt. The XON1Int interrupt can be routed to the ISR[1]
interrupt bit, if enabled through SpclChrIntEn[0].
ADDRESS: 0x06
MODE: COR
BIT 7 6 5 4 3 2 1 0
NAME MultiDropInt BREAKInt XOFF2Int XOFF1Int XON2Int XON1Int
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
29
SpclCharInt—Special Character Interrupt Register
Bits 7 and 4: No Function
Bit 6: SleepIntEn
Set the SleepIntEn bit high to route the SleepInt status bit to the ISR[2]: STSInt. If set low, the STSIntEn masks the ISR[2]
bit from SleepInt.
Bit 5: ClkRdyIntEn
Set the ClkRdyIntEn bit high to route the ClockReady status bit to the ISR[2]: STSInt bit. If set low, the ClkRdyIntEn
masks the ISR[2] bit from the ClockReady status.
Bits 3–0: GPI[3:0]IntEn
The GPI[3:0]IntEn bits that are set high route the associated STSInt[3:0]: GPI[3:0]Int bits to the ISR[2] interrupt. GPI[3:0]
IntEn bits that are set low, mask the ISR[2] interrupt from the associated GPI[3:0]Int bit.
Bits 7 and 4: No Function
Bit 6: SleepInt
The SleepInt bit is set when the MAX3107 enters sleep mode. The SleepInt bit is cleared when the MAX3107 exits sleep
mode. This status bit is cleared when the clock is disabled and cannot be cleared upon reading. The SleepInt bit can
generate an ISR[2]: STSInt interrupt, if enabled through STSIntEn[6].
Bit 5: ClockReady
The ClockReady bit is set high when the clock, the divider, and the PLL have settled, and the MAX3107 is ready for data
communication. The ClockReady bit only works with the crystal oscillator. It does not work with external clocking through
XIN.
The ClockReady status bit is cleared when the clock is disabled and is not cleared upon read. This bit can generate an
ISR[2]: STSInt interrupt, if enabled through STSIntEn[5].
Bits 3–0: GPI[3:0]Int
The GPI[3:0]Int interrupts are set high when a change of logic state occurs on the associated GPIO_ input. GPI[3:0]Int
is cleared upon reading. These interrupts can be selectively routed to the ISR[2] interrupt bit through the STSIntEn[3:0].
ADDRESS: 0x08
MODE: R/COR
BIT 7 6 5 4 3 2 1 0
NAME SleepInt ClockReady GPI3Int GPI2Int GPI1Int GPI0Int
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x07
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME SleepIntEn ClkRdyIntEn GPI3IntEn GPI2IntEn GPI1IntEn GPI0IntEn
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
30
STSInt—Status Interrupt Register
STSIntEn—STS Interrupt Enable Register
Bit 7: IRQSel
Depending on the logic level of the IRQSel bit, IRQ has different meanings. After a hardware or software (MODE2[0])
reset, the IRQSel bit is set low and after a short delay, the IRQ output signals the end of the MAX3107’s power-up
sequence. The IRQ is low during power-up and transitions to high when the MAX3107 is ready to be programmed.
IRQSel can then be set high. In this case, IRQ becomes a regular interrupt output that signals pending interrupts, as
indicated in the ISR. Details of the IRQSel are described in the Power-Up and IRQ section.
Bit 6: AutoSleep
Set the AutoSleep bit high to set the MAX3107 to automatically enter low-power sleep mode after a period of no activ-
ity (see the Autosleep Mode section). A STSInt[6]: SleepInt interrupt is generated when the MAX3107 goes to sleep or
wakes up.
Bit 5: ForcedSleep
Set the ForcedSleep bit high to force the MAX3107 into low-power sleep mode (see the Sleep Mode section). The current
sleep or wake state can be read out through this ForcedSleep bit, even when the UART is in sleep mode.
Bit 4: TrnscvCtrl
This bit enables the automatic transceiver direction control. Set TrnscvCtrl high so that RTS/CLKOUT automatically con-
trols the transceiver’s transmit/receive enable/disable inputs. Setting TrnscvCtrl high sets RTS/CLKOUT low so that the
transceiver is in receive mode. When the TxFIFO contains data available for transmission, the auto direction control sets
RTS/CLKOUT high before the transmitter sends out the data. When the transmitter is empty, RTS/CLKOUT is automati-
cally forced low again.
Setup and hold times of RTS/CLKOUT with respect to the TX output can be defined through the HDplxDelay register. A
transmitter empty interrupt ISR[5] is generated when the transmitter is empty.
Bit 3: RTSHiZ
Set the RTSHiZ bit high to three-state RTS/CLKOUT.
Bit 2: TxHiZ
Set the TxHiz bit high to three-state the TX output.
Bit 1: TxDisabl
Set the TxDisabl bit high to disable transmission. If the TxDisabl bit is set high during transmission, the transmitter com-
pletes sending out the current character and then ceases transmission. Data still present in the transmit FIFO remains
in the TxFIFO. The TX output is set to logic-high after transmission.
Bit 0: RxDisabl
Set the RxDisabl bit high to disable the receiver so that the receiver stops receiving data. All data present in the receive
FIFO remains in the RxFIFO.
ADDRESS: 0x09
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME IRQSel AutoSleep ForcedSleep TrnscvCtrl RTSHiZ TxHiZ TxDisabl RxDisabl
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
31
MODE1 Register
Bit 7: EchoSuprs
Set the EchoSuprs bit high so that the MAX3107’s receiver gates any data it receives when its transmitter is busy
transmitting. In half-duplex communication (like IrDA and RS-485) this allows blocking of the locally echoed data. The
receiver can block data for an extended time after the transmitter ceases transmission by programming a hold time in
HDplxDelay[3:0] bits.
Bit 6: MultiDrop
Set the MultiDrop bit high to enable the 9-bit multidrop mode. If this bit is set, parity checking is not performed by the
receiver and parity generation is not done by the transmitter. The parity error bit, LSR[2], has a different meaning in this
case. The parity error bit represents the 9th bit (address/data indication) that is received with each 9-bit character.
Bit 5: Loopback
Set the Loopback bit high to enable internal local loopback mode. This internally connects TX to RX and also RTS/
CLKOUT to CTS. In local loopback mode, the TX output and the RX output are disconnected from the internal transmit-
ter and receiver. The TX output is in three-state. The RTS output remains connected to the internal logic and reflects the
logic state programmed in LCR[7]. The CTS input is disconnected from RTS and the internal logic. CTS thus remains in
a high-impedance state.
Bit 4: SpecialChr
The SpecialChr bit enables special character detection. The receiver can detect up to four special characters, as selected
in FlowCtrl:[5:4] and defined in the XON1, XON2, XOFF1 and/or XOFF2 registers, possibly in combination with GPIO_
inputs, enabled through FlowCtrl[2]: GPIAddr. When a special character is received it is put into the RxFIFO and a special
character detect interrupt ISR[1] is generated.
Special character detection can be used in addition to auto XON/XOFF flow control, if enabled through FlowCtrl[3]. In
this case XON/OFF flow control is then limited to single character XON and XOFF and only two special characters can
then be defined (in XON2 and XOFF2).
Bit 3: RxEmtyInv
The RxEmtyInv bit inverts the meaning of the receiver empty interrupt: ISR[6]: RxEmtyInt. If RxEmtyInv is set low (default
state), the ISR[6] interrupt is generated when the receive FIFO is empty. If the RxEmtyInv is set high, the ISR[6] interrupt
is generated when data is put into the empty receive FIFO.
Bit 2: RxTrigInv
The RxTrigInv bit inverts the meaning of the RxFIFO triggering. When set, an ISR[3]: RFifoTrigInt is generated when
the RxFIFO is emptied to the trigger level: FIFOTrgLvl[7:4]. If the RxTrgInv bit is low (default state), the ISR[3] interrupt
is generated when the RxFIFO fill level that starts from a level below FIFOTrgLvl[7:4] is filled up to the trigger level pro-
grammed into FIFOTrgLvl[7:4].
Bit 1: FIFORst
Set the FIFORst bit high to clear both the receive and transmit FIFOs of all data contents. After the FIFO reset, the
FIFORst bit must then be set back to 0 to continue normal operation.
Bit 0: RST
Set the RST bit high to reset the MAX3107. The SPI/I2C bus stays active during this reset, therefore, communication with
the MAX3107 is possible. All register bits are reset to their reset state and all FIFOs are cleared.
Once set high, the RST bit must be cleared by writing a 0 to RST.
ADDRESS: 0x0A
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME EchoSuprs MultiDrop Loopback SpecialChr RxEmtyInv RxTrigInv FIFORst RST
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
32
MODE2 Register
Bit 7: RTS
The RTS bit gives direct control of the RTS/CLKOUT output logic. If the RTS bit is set high, then RTS/CLKOUT is set to
logic-high. The RTS bit only works if the CLKSource[7]:CLKtoRTS is not set high.
Bit 6: TxBreak
Set TxBreak to 1 to generate a line break whereby the TX output is held low until TxBreak is set to 0.
Bit 5: ForceParity
ForceParity enables forced parity, as used in 9-bit multidrop communication. Set both LCR[3] and ForceParity to use
forced parity. The parity bit is forced high by the transmitter if LCR[4] low. The parity bit is forced low if LCR[4] is high.
Bit 4: EvenParity
Set EvenParity high to enable even parity. If EvenParity is set low odd parity generation/checking is used.
Bit 3: ParityEn
The ParityEn bit enables the use of a parity bit on the TX and RX interfaces. When ParityEn is low, then parity usage is
disabled. When ParityEn is set to 1, the transmitter generates the parity bit as defined in LCR[4] and the receiver checks
the received parity bit.
Bit 2: StopBits
This defines the number of STOP bits and depends on the length of the word programmed in LCR[1:0] (Table 1). When
StopBits is high and the word length is 5, the transmitter generates a word with a STOP bit length equal to 1.5. Under
these conditions, the receiver recognizes a STOP bit length greater than a 1-bit duration.
Bits 1 and 0: Length[1:0]
The Length[1:0] bits configure the length of the words that the transmitter generates and the receiver checks for at the
asynchronous TX and RX interfaces (Table 2).
Table 2. Length[1:0] Truth TableTable 1. StopBits Truth Table
Length1 Length0 WORD LENGTH
0 0 5
0 1 6
1 0 7
1 1 8
LCR[2] WORD LENGTH STOP BIT LENGTH
0 5, 6, 7, 8 1
1 5 1–1.5
1 6, 7, 8 2
ADDRESS: 0x0B
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME RTS TxBreak ForceParity EvenParity ParityEn StopBits Length1 Length0
RESET 0 0 0 0 0 1 0 1
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
33
LCR—Line Control Register
Bits 7–0: TimOut[7:0]
The receive data timeout bits allow programming a time delay after the last (newest) character in the receive FIFO was
received until a receive data timeout LSR[0] interrupt is generated. The duration is measured in character intervals and
is dependent on the character length, parity, and STOP bit setting and is inversely proportional to the baud rate. If the
RxTimeOut value equals zero, a timeout interrupt is not generated.
The HDplxDelay register allows programming setup and hold times between RTS/CLKOUT and the TX output in auto
transceiver direction control mode: MODE1[4] is 1. The Hold[3:0] time can also be used for echo suppression in half-
duplex communication. HDplxDelay also functions in the 2x and 4x rate modes.
Bits 7–4: Setup[7:4]
The Setupx bits define a setup time for RTS/CLKOUT to transition high before the transmitter starts transmission of its
first character in auto transceiver direction control mode: MODE1[4]. This allows the MAX3107 to account for skew dif-
ferences of the external transmitter’s enable delay and propagation delays. Setup[7:4] can also be used to fix a stable
state on the transmission line prior to start of transmission.
The unit of the HDplxDelay setup time delay is a 1-bit interval, making this delay baud-rate dependent. The maximum
delay is 15-bit intervals.
Bits 3–0: Hold[3:0]
The Hold[3:0] bits define a hold time for RTS/CLKOUT to be held stable (high) after the transmitter ends transmission of
its last character in auto transceiver direction control mode: MODE1[4]. RTS/CLKOUT turns low after the last STOP bit
was sent with a Hold[3:0] delay. This keeps the external transmitter enabled during the hold duration.
The second factor that the Hold[3:0] bits define, is a delay in echo suppression mode, MODE2[7]. See the Echo
Suppression section for more information.
The unit of the HDplxDelay hold time delay is a 1-bit interval, making the delay baud-rate dependent. The maximum
delay is 15-bit intervals.
ADDRESS: 0x0D
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Setup3 Setup2 Setup1 Setup0 Hold3 Hold2 Hold1 Hold0
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x0C
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME TimOut7 TimOut6 TimOut5 TimOut4 TimOutO3 TimOut2 TimOut1 TimOut0
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
34
HDplxDelay Register
RxTimeOut—Receiver Timeout Register
The IrDA allows selection of IrDA SIR and MIR-compliant pulse shaping at the TX and RX interfaces. It also allows inver-
sion of the TX and RX logic, independently of whether IrDA is enabled or not.
Bits 7 and 6: No Function
Bit 5: TxInv
Set the TxInv bit high to invert the logic at the TX output. This is independent of IrDA operation.
Bit 4: RxInv
Set the RxInv bit high to invert the logic state at the RX input. This is independent of IrDA operation.
Bit 3: MIR
Set the MIR and IrDAEn bits high to select IrDA 1.1 (MIR) with 1/4 period pulse widths.
Bit 2: No Function
Bit 2 must be kept logic 0.
Bit 1: SIR
Set the SIR bit and the IrDAEn bits high to select IrDA 1.0 pulses (SIR) with 3/16th period pulses.
Bit 0: IrDAEn
Set the IrDAEn bit high so that IrDA-compliant pulses are produced at the TX output and the MAX3107 receiver expects
such pulses at its Rx input. If IrDAEn is set to low (default), normal (nonIrDA) pulses are generated and expected at the
receiver. IrDAEn must be used in conjunction with the SIR or MIR select bits.
FlowLvl is used for selecting the RxFIFO threshold levels used for software (XON/XOFF) and hardware (RTS/CTS) flow control.
Bits 7–4: Resume[7:4]
Resume[7:4] sets the transmit FIFO threshold at which an XON is automatically sent or RTS/CLKOUT is automati-
cally set low. This signals the far-end station to start transmission. The actual threshold level is calculated as 8 times
Resume[7:4]. The resulting level is in the range of 0 to 120.
Bits 3–0: Halt[3:0]
Halt[3:0] sets a receive FIFO threshold level at which an XOFF is automatically sent or RTS/CLKOUT is automatically
set high, depending on whether auto software or hardware flow control is enabled. This signals the far-end station to halt
transmission. The actual threshold level is calculated as 8 times Halt[3:0]. Hence, the selectable threshold granularity is
eight. The resulting level is in the range of 0 to 120.
ADDRESS: 0x0F
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Resume3 Resume2 Resume1 Resume0 Halt3 Halt2 Halt1 Halt0
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x0E
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME TxInv RxInv MIR SIR IrDAEn
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
35
FlowLvl—Flow Level Register
IrDA Register
Bits 7–4: RxTrig[3:0]
These 4 bits allow definition of the receive FIFO threshold level at which an ISR[3] interrupt is generated. This can be used
to signal that the receive FIFO is nearing overflow or that a predefined number of FIFO locations are available for being read
out in one block. The actual FIFO trigger level is 8 times RxTrig[7:4], hence, the selectable threshold granularity is eight.
Bits 3–0: TxTrig[3:0]
These 4 bits allow definition of the transmit FIFO threshold level at which the MAX3107 generates an ISR[4] interrupt. This can
be used to manage data flow to the transmit FIFO. For example, if the trigger level is defined near the bottom of the TxFIFO, the
host knows that a predefined number of FIFO locations are available for being written to in one block. Alternatively, if the trigger
level is set near the top of the FIFO, the host is warned when the transmit FIFO is nearing overflow, if written to on a word-by-
word basis. The actual FIFO trigger level is 8 times TxTrig[3:0], hence, the selectable threshold granularity is eight.
Bits 7–0: TxFL[7:0]
The TxFIFOLvl register represents the current number of words in the transmit FIFO whenever the transmit UART is
idle. When the transmit UART actively sends out characters, the value in this register can sometimes be inaccurate if
this register is read at the same time that the transmit UART updates the transmit FIFO. First, disable the transmitter to
get an accurate value. To manage the transmit FIFO even when the transmit UART is active, do not use this register to
determine transmit FIFO state. Rather, use the TFifoEmpty bit or the TFifoTrigInt bits.
Bits 7–0: RxFL[7:0]
The RxFIFOLvl register represents the current number of words in the receive FIFO whenever the receive UART is
idle. When the receive UART actively receives characters, the value in this register can sometimes be inaccurate if this
register is read at the same time that the receive UART updates the receive FIFO. To manage the receive FIFO even
when the receive UART is active, do not use this register to determine receive FIFO state. Use the RFIFOEmptyInt bit,
the RxTrgInt bit, and the RTimeOut bit instead.
ADDRESS: 0x12
MODE: R
BIT 7 6 5 4 3 2 1 0
NAME RxFL7 RxFL6 RxFL5 RxFL4 RxFL3 RxFL2 RxFL1 RxFL0
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x11
MODE: R
BIT 7 6 5 4 3 2 1 0
NAME TxFL7 TxFL6 TxFL5 TxFL4 TxFL3 TxFL2 TxFL1 TxFL0
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x10
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME RxTrig3 RxTrig2 RxTrig1 RxTrig0 TxTrig3 TxTrig2 TxTrig1 TxTrig0
RESET 1 1 1 1 1 1 1 1
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
36
RxFIFOLvl—Receive FIFO Level Register
TxFIFOLvl—Transmit FIFO Level Register
FIFOTrgLvl—FIFO Interrupt Trigger Level Register
Bits 7–4: SwFlow[3:0]
The SwFlow[3:0] bits configure auto software flow control and/or special character detection in combination with the
characters defined in the XON1, XON2, XOFF1 and/or XOFF2 registers. See Table 3.
FlowCtrl[5:4] select which of the XON1, XON2, XOFF1 or/and XOFF2 characters are used for special character detec-
tion and/or auto flow control. If auto receiver flow control is enabled through SwFlowEn and FlowCtrl[7:6], the XON and
XOFF characters that the MAX3107 receives are filtered out and are not put into the RxFIFO. Set the SwFlowEn bit
to 0 and set MODE2[4] to 1 to only enable special character detection. Under these conditions, auto flow transmit flow
control is not active.
If both special character detection (MODE2[4]) and auto software flow control (FlowCtrl[3]) are to be enabled, XON1 and
XOFF1 define the auto flow control characters, while XON2 and XOFF2 define the special character detection characters.
Bit 3: SwFlowEn
The SwFlowEn bit enables auto software flow control. The characters used for auto software flow control are selected in
SwFlow[7:4]. If special character detection (MODE2[4] set to 1) is used in addition to auto software flow control, XON1
and XOFF1 are used for flow control, while XON2 and XOFF2 define the special characters.
Bit 2: GPIAddr
The GPIAddr bit, when set, enables that the four GPIO_ inputs are used in conjunction with XOFF2 for the definition of
a special character. This can be used, for example, for defining the address of a RS-485 slave device through hardware.
The GPIO_ inputs logic levels, which define the 4 LSBs of the special character, while the 4 MSBs are defined by the
XOFF2[7:4] bits. If GPIAddr is set, the contents of the XOFF2[3:0] bits are neglected. In this case, the XOFF2[3:0] bits,
when read, also do not reflect the logic on GPIO_.
Bit 1: AutoCTS
The AutoCTS bit enables auto CTS flow control by which the transmitter stops and starts sending data depending on
the logic state at the CTS input. See the Auto Hardware Flow Control section for a description of AutoCTS flow con-
trol. Logic changes at the CTS input result in an ISR[7]: CTSInt interrupt. The transmitter must be turned off by setting
MODE1[1] to 1 before AutoCTS is enabled.
Bit 0: AutoRTS
The AutoRTS bit enables auto RTS flow control by which the MAX3107 sets its RTS/CLKOUT output dependent on
the receive FIFO fill level. The FIFO thresholds at which RTS/CLKOUT changes state are set in FlowLvl. See the Auto
Hardware Flow Control section for more information.
ADDRESS: 0x13
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME SwFlow3 SwFlow2 SwFlow1 SwFlow0 SwFlowEn GPIAddr AutoCTS AutoRTS
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
37
FlowCtrl—Flow Control Register
The XON1 and XON2 register contents define the XON characters used for auto XON/XOFF flow control and/or the
special characters used for special character detection. See details in the FlowCtrl register description.
Bits 7–0: Bit[7:0]
These bits define the XON1 character if single-character XON auto software flow control is enabled in FlowCntrl[7:4].
If double-character flow control is selected in FlowCntrl[7:4], these bits constitute the LSB of the XON character. If
special character detection is enabled in MODE2[4] and auto flow control is not enabled, these bits define a special
character. If special character detection and auto software flow control are enabled, XON1 defines the XON flow
control character.
X = Don’t care
Table 3. SwFlow[3:0] Truth Table
ADDRESS: 0x14
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
RESET 0 0 0 0 0 0 0 0
SwFlow3 SwFlow2 SwFlow1 SwFlow0
DESCRIPTION
RECEIVER FLOW CONTROL
TRANSMITTER FLOW
CONTROL/SPECIAL
CHARACTER DETECTION
0 0 0 0 No ow control/no character detection.
0 0 X X No receiver ow control.
1 0 X X Transmitter generates XON1, XOFF1.
0 1 X X Transmitter generates XON2, XOFF2.
1 1 X X Transmitter generates XON1, XON2, XOFF1, and XOFF2.
X X 0 0 No transmitter ow control.
X X 1 0
Receiver compares XON1 and XOFF1 and controls the
transmitter accordingly. XON1 and XOFF1 special character
detection.
X X 0 1
Receiver compares XON2 and XOFF2 and controls the
transmitter accordingly. XON2 and XOFF2 special character
detection.
X X 1 1
Receiver compares XON1, XON2, XOFF1, and XOFF2 and
controls the transmitter accordingly. XON1, XON2, XOFF1,
and XOFF2 special character detection.
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
38
XON1 Register
The XON1 and XON2 register contents define the XON characters for auto XON/XOFF flow control and/or the special
characters used in special character detection. See details in the FlowCtrl register description.
Bits 7–0: Bit[7:0]
These bits define the XON2 character if single-character auto software flow control is enabled in FlowCntrl[7:4]. If
double-character flow control is selected in FlowCntrl[7:4], these bits constitute the MSB of the XON character. If special
character detection is enabled in MODE2[4], and auto software flow control is not enabled, these bits define a special
character. If both special character detection and auto software flow control are enabled (MODE2[4] and FlowCntrl[3]),
these bits define a special character.
The XOFF1 and XOFF2 register contents define the XOFF characters for auto XON/XOFF flow control and/or the special
characters used in special character detection. See details in the FlowCtrl register description.
Bits 7–0: Bit[7:0]
These bits define the XOFF1 character if single-character XOFF auto software flow control is enabled in FlowCntrl[7:4].
If double character flow control is selected in FlowCntrl[7:4], these bits constitute the LSB of the XOFF character. If
special character detection is enabled in MODE2[4] and auto software flow control is not enabled, these bits define a
special character. If special character detection and software flow control are both enabled, XOFF1 defines the XOFF
flow control character.
ADDRESS: 0x16
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x15
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
39
XOFF1 Register
XON2 Register
The XOFF1 and XOFF2 register contents define the XOFF characters for auto XON/XOFF flow control and/or special
characters used in special character detection. See details in the FlowCtrl register description.
Bits 7–0: Bit[7:0]
These bits define the XOFF2 character if auto software flow control is enabled in FlowCntrl[7:4]. If double-character flow
control is selected in FlowCntrl[7:4], these bits constitute the MSB of the XOFF character. If special character detection is
enabled in MODE2[4] and auto flow control is not enabled, these bits define a special character. If both special character
detection and auto flow control are enabled (MODE2[4] and FlowCntrl[3]), these bits define a special character.
The four GPIOs can be configured as inputs or outputs and can be operated in push-pull or open-drain mode. The
reference clock has to be active for the GPIOs to work.
Bits 7–4: GP[3:0]OD
Set the GP[3:0]OD bits to 1 to configure open-drain output or input operation. If GP[3:0]OD are 0 (default), the GPIO_are
push-pull outputs, if configured as outputs in GPIOConfg[3:0]. If configured as inputs in GPIOConfg[3:0], the GPIO_ are
high-impedance inputs with weak pulldowns.
Bits 3–0: GP[3:0]Out
The GP[3:0]Out bits configure the GPIO_ to be inputs or outputs. Set the GP[3:0]Out bits high to configure the associated
GPIO_ as outputs. The GP[3:0]Out bits which are set low, are configured to be inputs.
Bits 7–4: GPI[3:0]Dat
The GPI[3:0]Dat bits reflect the logic on GPIO_ when configured as inputs through GPIOConfg[3:0].
Bits 3–0: GPO[3:0]Dat
The GPO[3:0]Dat bits allows programming the logic state of the GPIO_, when these are configured as outputs through
GPIOConfg[3:0]. For open-drain operation, pullup resistors are needed on GPIO_.
ADDRESS: 0x19
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME GPI3Dat GPI2Dat GPI1Dat GPI0Dat GPO3Dat GPO2Dat GPO1Dat GPO0Dat
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x18
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME GP3OD GP2OD GP1OD GP0OD GP3Out GP2Out GP1Out GP0Out
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x17
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
40
GPIOData—GPIO Data Register
GPIOConfg—GPIO Configuration Register
XOFF2 Register
Bits 7 and 6: PLLFactor[1:0]
The two PLLFactor[1:0] bits allow programming the PLL’s multiplication factor. The input and output frequencies of the
PLL have to be limited to the ranges shown in Table 4. Enable the PLL through CLKSource[2].
Bits 5–0: PreDiv[5:0]
The six PreDiv[5:0] bits allow programming the divisor of the PLL’s predivider. The divisor must be chosen such that
the output frequency of the predivider, which equals the PLL’s input frequency, is limited to the ranges shown in Table 4. The
input frequency of XIN is fCLK; fPLLIN = fCLK/PreDiv (Figure 4). PreDiv is an integer that must be in the range of 1 to 63.
Table 4. PLLFactor[1:0] Selection Guide
Figure 14. PLL Signal Path
PLLFactor1 PLLFactor0 MULTIPLICATION
FACTOR
fPLLIN fREF
MIN (kHz) MAX MIN (MHz) MAX (MHz)
0 0 6 500 800kHz 3 4.8
0 1 48 850 1.2MHz 40.8 56
1 0 96 425 1MHz 40.8 96
1 1 144 390 667kHz 56 96
ADDRESS: 0x1A
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME PLLFactor1 PLLFactor0 PreDiv5 PreDiv4 PreDiv3 PreDiv2 PreDiv1 PreDiv0
RESET 0 0 0 0 0 0 0 1
PREDIVIDER
fCLK PLL
fPLLIN fREF FRACTIONAL
BAUD-RATE
GENERATOR
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
41
PLLConfig—PLL Configuration Register
Bits 7 and 6: No Function
Bit 5: 4xMode
When the 4xMode bit is set high, the MAX3107 baud rate is quadruple the regular (16x sampling) baud rate. The 2xMode
bit should be set low if 4xMode is enabled. See the 2x and 4x Rate Modes section for more information.
Bit 4: 2xMode
When the 2xMode bit is set high, the MAX3107 baud rate is double the regular (16x sampling) baud rate. See the 2x and
4x Rate Modes section for a detailed description.
Bits 3–0: FRACT[3:0]
This is the fractional portion of the baud-rate generator divisor. Set FRACT[3:0] to zero if not used. See the Fractional
Baud-Rate Generator section for calculations.
DIVLSB and DIVMSB define the baud-rate generator integer divisors. The minimum value is 1. See the Fractional Baud
Rate Generator section for more information.
Bits 7–0: Div[7:0]
Div[7:0] are the 8 LSBs of the integer divisor portion (DIV) of the baud-rate generator.
Bits 7–0: Div[15:8]
Div[15:8] is the MSB portion of the integer divisor (DIV).
ADDRESS: 0x1D
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Div15 Div14 Div13 Div12 Div11 Div10 Div9 Div8
RESET 0 0 0 0 0 0 0 0
ADDRESS: 0x1C
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME Div7 Div6 Div5 Div4 Div3 Div2 Div1 Div0
RESET 0 0 0 0 0 0 0 1
ADDRESS: 0x1B
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME 4xMode 2xMode FRACT3 FRACT2 FRACT1 FRACT0
RESET 0 0 0 0 0 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
42
DIVMSB—Baud-Rate Generator MSB Divisor Register
DIVLSB—Baud-Rate Generator LSB Divisor Register
BRGConfig—Baud-Rate Generator Configuration Register
Bit 7: CLKtoRTS
Set the CLKtoRTS bit to 1 to route the baud-rate generator (16x baud rate) output clock to RTS/CLKOUT. The clock
frequency is a factor of 16x, 8x, or 4x of the baud rate, depending on the BRGConfig[5:4] settings.
Bits 6 and 5: No Function
Bit 4: ClockEn
Set the ClockEn bit high to enable an external clocking (crystal or clock generator at XIN). Set the ClockEn bit to 0 to
disable clocking.
Bit 3: PLLBypass
Set the PLLBypass bit high to enable bypassing the internal PLL and predivider.
Bit 2: PLLEn
Set the PLLEn bit high to enable the internal PLL. If PLLEn is set low, the internal PLL is disabled.
Bit 1: CrystalEn
Set the CrystalEn bit high to enable the crystal oscillator. When using an external clock source at XIN, CrystalEn must
be set low.
Bit 0: No Function
Always keep Bit 0 at logic 0.
Bit 7–0: Bit[7:0]
The RevID register indicates the revision number of the MAX3107 silicon, starting with 0xA1. This can be used during
software development.
ADDRESS: 0x1F
MODE: R
BIT 7 6 5 4 3 2 1 0
NAME Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
RESET 1 0 1 0 0 0 0 1
ADDRESS: 0x1E
MODE: R/W
BIT 7 6 5 4 3 2 1 0
NAME CLKtoRTS ClockEn PLLBypass PLLEn CrystalEn
RESET 0 0 0 0 1 0 0 0
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
43
RevID—Revision Identification Register
CLKSource—Clock Source Register
Serial Controller Interface
The MAX3107 can be controlled through SPI or I2C as
defined by the logic on I2C/SPI. See the Pin Configurations
for further details.
SPI Interface
The SPI supports both single-cycle and burst-read/write
access. The SPI master must generate clock and data
signals in SPI MODE0 (i.e., with clock polarity CPOL = 0
and clock phase CPHA = 0).
SPI Single-Cycle Access
Figure 15 shows a single-cycle read and Figure 16 shows
a single-cycle write.
SPI Burst Access
Burst access allows writing and reading in one block by
only defining the initial register address in the SPI com-
mand byte. Multiple characters can be loaded into the
transmit FIFO by using the THR (0x00) as the initial burst
read address. Similarly, multiple characters can be read
out of the receiver FIFO by using the RHR (0x00) as the
SPI’s burst read address. If the SPI burst address is dif-
ferent to 0x00, the MAX3107 automatically increments
the register address after each SPI data byte. Efficient
programming of multiple consecutive registers is thus
possible. Chip select, CS/A0, must be kept low during
the whole cycle. The SCLK/SCL clock continues clocking
throughout the burst access cycle. The burst cycle ends
when the SPI master pulls CS/A0 high.
For example, writing 128 bytes into the TxFIFO can be
achieved by a burst write access through the following
sequence:
Pull CS/A0 low
Send SPI write command
Send 128 byes
Release CS/A0
This takes a total of (1 + 128) x 8 clock cycles.
I2C Interface
The MAX3107 contains an I2C-compatible interface for
data communication with a host processor (SCL and
SDA). The interface supports a clock frequency up to
400kHz. SCL and SDA require pullup resistors that are
connected to a positive supply.
Figure 16. SPI Single-Cycle Write
Figure 15. SPI Single-Cycle Read
CS
W A6 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0
SCLK
SDI
A_ = REGISTER ADDRESS
D_ = 8-BIT REGISTER CONTENTS
CS
R A6 A5 A4 A3 A2 A1 A0
D7 D6 D5 D4 D3 D2 D1 D0
SCLK
SDI
SDO
A_ = REGISTER ADDRESS
D_ = 8-BIT REGISTER CONTENTS
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
44
START, STOP, and Repeated START Conditions
When writing to the MAX3107 using I2C, the master
sends a START condition (S) followed by the MAX3107
I2C address. After the address, the master sends
the register address of the register that is to be pro-
grammed. The master then ends communication by
issuing a STOP condition (P) to relinquish control of the
bus, or a repeated START condition (Sr) to communicate
to another I2C slave. See Figure 17.
Slave Address
The MAX3107 includes a 7-bit slave address. The first 5
bits (MSBs) of the slave address are factory-programmed
and always 01011. These slave addresses are unique
device IDs. Connect A1, A0 to ground or VL to set the
I2C slave address (Table 5). The address is defined as
the 7 MSBs followed by the read/write bit. Set the read/
write bit to 1 to configure the MAX3107 to read mode. Set
the read/write bit to 0 to configure the MAX3107 to write
mode. The address is the first byte of information sent to
the MAX3107 after the START condition.
Bit Transfer
One data bit is transferred during each SCL clock cycle.
The data on SDA must remain stable during the high
period of the SCL clock pulse. Changes in SDA while
SCL is high and stable are considered control signals
(see the START, STOP, and Repeated START Conditions
section). Both SDA and SCL remain high when the bus is
not active.
Single-Byte Write
With this operation the master sends an address and 1
or 2 data bytes to the slave device (Figure 18). The write
byte procedure is as follows:
1) The master sends a START condition.
2) The master sends the 7-bit slave ID plus a write bit
(low).
3) The addressed slave asserts an ACK on the data line.
4) The master sends the 8-bit register address.
5) The active slave asserts an ACK on the data line only
if the address is valid (NACK if not).
6) The master sends the 8-bit data byte.
7) The slave asserts an ACK on the data line.
8) The master generates a STOP condition.
Burst Write
With this operation the master sends an address and mul-
tiple data bytes to the slave device (Figure 19). The burst
write procedure is as follows:
1) The master sends a START condition.
Figure 17. I2C START, STOP, and Repeated START Conditions
Table 5. I2C Address Map
DIN/A1 CS/A0 READ/
WRITE I2C ADDRESS
0 0 W 0x58
R 0x59
0 1 W 0x5A
R 0x5B
1 0 W 0x5C
R 0x5D
1 1 W 0x5E
R 0x5F
SCL
SDA
S Sr P
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
45
2) The master sends the 7-bit slave ID plus a write bit (low).
3) The addressed slave asserts an ACK on the data
line.
4) The master sends the 8-bit register address.
5) The slave asserts an ACK on the data line only if the
address is valid (NACK if not).
6) The master sends 8 bits of data.
7) The slave asserts an ACK on the data line.
8) Repeat steps 6 and 7 N - 1 times.
9) The master generates a STOP condition.
Single-Byte Read
With this operation the master sends an address and
receives 1 or 2 data bytes from the slave device (Figure 20).
The read byte procedure is as follows:
1) The master sends a START condition.
2) The master sends the 7-bit slave ID plus a write bit (low).
3) The addressed slave asserts an ACK on the data line.
4) The master sends the 8-bit register address.
5) The active slave asserts an ACK on the data line only
if the address is valid (NACK if not).
6) The master sends a repeated START (Sr).
7) The master sends the 7-bit slave ID plus a read bit (high).
Figure 20. Read Byte Sequence
Figure 19. Burst Write Sequence
Figure 18. Write Byte Sequence
S
Sr
DEVICE SLAVE ADDRESS - W A
DEVICE SLAVE ADDRESS - R
READ SINGLE BYTE
A
REGISTER ADDRESS A
8 DATA BITS NA
FROM MASTER TO STAVE FROM SLAVE TO MASTER
P
S DEVICE SLAVE ADDRESS - W A
8 DATA BITS - 1
BURST WRITE
A
REGISTER ADDRESS A
8 DATA BITS - N A
8 DATA BITS - 2 A
FROM MASTER TO STAVE FROM SLAVE TO MASTER
P
S
P
DEVICE SLAVE ADDRESS - W A
8 DATA BITS
FROM MASTER TO STAVE
WRITE SINGLE BYTE
FROM SLAVE TO MASTER
A
REGISTER ADDRESS A
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
46
8) The addressed slave asserts an ACK on the data
line.
9) The slave sends 8 data bits.
10) The master asserts a NACK on the data line.
11) The master generates a STOP condition.
Burst Read
With this operation the master sends an address and
receives multiple data bytes from the slave device
(Figure 21). The burst read procedure is as follows:
1) The master sends a START condition.
2) The master sends the 7-bit slave ID plus a write bit (low).
3) The addressed slave asserts an ACK on the data line.
4) The master sends the 8-bit register address.
5) The slave asserts an ACK on the data line only if the
address is valid (NACK if not).
6) The master sends a repeated START condition.
7) The master sends the 7-bit slave ID plus a read bit
(high). 8) The slave asserts an ACK on the data line.
9) The slave sends 8 bits of data.
10) The master asserts an ACK on the data line.
11) Repeat steps 9 and 10 N - 1 times.
12) The master generates a STOP condition.
Acknowledge
Data transfers are acknowledged with an acknowledge
bit (ACK) or a not-acknowledge bit (NACK). Both the
master and the MAX3107 generate ACK bits. To gener-
ate an ACK, pull SDA low before the rising edge of the
9th clock pulse and keep it low during the high period
of the 9th clock pulse (see Figure 22). To generate a
NACK, leave SDA high before the rising edge of the 9th
clock pulse and keep it high for the duration of the 9th
clock pulse. Monitoring for NACK bits allows for detection
of unsuccessful data transfers.
Applications Information
Startup and Initialization
The MAX3107 can be initialized following power-up or
a hardware or software reset as shown in Figure 23.
To verify that the MAX3107 is ready for operation after
a power-up or reset, check the IRQ output if interrupt
driven operation is employed.
In polled mode, repeatedly read a known register until
the expected contents are returned. Note that the con-
tents of the RevID change if new revisions of the product
are released. If reading RevID, it is recommended to only
check for the most significant 4 bits: Ah.
Figure 22. Acknowledge
Figure 21. Burst Read Sequence
NOT ACKNOWLEDGE
ACKNOWLEDGE
1 2 8 9
SDA
SCL
S
S
Sr
DEVICE SLAVE ADDRESS - W A
DEVICE SLAVE ADDRESS - R
BURST READ
A
REGISTER ADDRESS A
8 DATA BITS - 1 A
A 8 DATA BITS - 38 DATA BITS - 2 A
8 DATA BITS - N A
FROM MASTER TO STAVE FROM SLAVE TO MASTER
P
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
47
Low-Power Operation
To reduce the power consumption during normal opera-
tion, the following techniques can be adopted:
Do not use the internal PLL. This saves the most
power of the options listed here. Disable and bypass
the PLL. With the PLL enabled, the current to the
VA supply is in the range of a few mA (depending
on clock and multiplication factor), while it drops to
below 1mA if disabled.
Keep the internal clock rates as low as possible.
Use low voltage on the VA supply.
Use an external 1.8V supply. This saves the power
dissipated in the internal 1.8V linear regulator for the
1.8V logic supply. Connect the external 1.8V supply to
V18 and disable the internal regulator by connecting
LDOEN to DGND.
Interrupts and Polling
The host controller can manage and control the MAX3107
through polling and/or through interrupts. In polled
mode, the IRQ physical interrupt output is not used and
the host controller polls the ISR register at frequent inter-
vals to establish the state of the MAX3107.
Alternatively, the MAX3107’s physical IRQ interrupt can
be used to interrupt the host controller at specified events,
making polling unnecessary. The IRQ output is an open-
drain output that requires a pullup resistor to VL.
Logic-Level Translation
The MAX3107 can be directly connected to transceivers
and controllers that have different supply voltages. The
VL input defines the logic voltage levels of the controller
interface while the VEXT voltage defines the logic of the
transceiver interface. This ensures flexibility when select-
ing a controller and transceiver. Figure 24 is an example
of a setup when the controller, transceiver, and the
MAX3107 are powered by three different supplies.
Figure 23. Startup and Initialization Flowchart
POWER-UP/
RST INPUT PULLED HIGH/
RST BIT SET LOW
IS IRQ HIGH?
OR
RevID READ
SUCCESSFULLY
Y
N
CONFIGURE
CLOCKING
CONFIGURE
MODES
CONFIGURE
FIFO CONTROL
CONFIGURE
FLOW CONTROL
CONFIGURE
GPIOs
START
COMMUNICATION
ENABLE
INTERRUPTS
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
48
Connector Pin Sharing
The TX and RTS/CLKOUT outputs can be programmed
to be high impedance. This can be used in cases where
the MAX3107 shares a common connector with other
communication devices. Set the output of the MAX3107
to high impedance when the other communication
devices are active. Program MODE1[2]: TxHiZ high to
set TX to a high-impedance state. Program MODE1[3]:
RTSHiZ high to set RTS/CLKOUT to a high-impedance
state. Figure 25 shows an example of connector sharing
with a USB transceiver.
RS-232 5x3 Application
The four GPIOs can be used to implement the other flow-
control signals defined in ITU V.24. Figure 26 shows how
the GPIOs create the DSR, DTR, DCD, and RI signals
found on some RS-232/V.28 interfaces.
Set FlowCtrl[1:0] high to enable auto hardware RTS/CTS
flow control.
Typical Application Circuit
Figure 27 shows the MAX3107 being used in a half-duplex
RS-485 application. The microcontroller, the RS-485
transceiver, and the MAX3107 are powered by 3.3V. SPI
is used as the controller’s communication interface.
The MAX14840 receiver is continually enabled so that
echoing occurs. Enable auto echo suppression in the
MAX3107 UART by setting MODE2[7]: EchoSuprs to 1.
Set MODE1[4]: TranscvCtrl high to enable auto trans-
ceiver direction control to automatically control the DE
input of the transceiver.
Ordering Information
Figure 25. Connector Sharing with a USB Transceiver
Figure 24. Logic-Level Translation
+Denotes a lead(Pb)-free/RoHS-compliant package.
T = Tape and reel.
*EP = Exposed pad.
/V denotes an automotive qualified part
PART TEMP RANGE PIN-PACKAGE
MAX3107EAG+T -40°C to +85°C 24 SSOP
MAX3107ETG+T -40°C to +85°C 24 TQFN-EP*
MAX3107ETG/V+T -40°C to +85°C 24 TQFN-EP*
MAX3107
TX
RX
MAX13481E
D+
D-
OE
TX/D+
RX/D-
SHARED
CONNECTOR
MAX3107
TX
RX
RTS/CLKOUT
AGND DGND
VLVAVEXT
RST
IRQ
SPI/I2C
MAX3078
TRANSCEIVER
VCC
DI
DE
RO
VDD
2.5V
1.8V 3.3V
MICROCONTROLLER
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
49
Chip Information
PROCESS: BiCMOS
Figure 27. RS-485 Half-Duplex Application
Figure 26. RS-232 Application
MAX14840
A
B
DI
RO
RE
DE
MAX3107
TX
RX
XOUT
AGND V18 DGND
100nF
VEXT VAVL
IRQ
SPI/I2C
LDOEN
RST
XIN
SPI
3.3V
MICROCONTROLLER
CLOCK
RTS
10k
1µF
100nF
MAX3107
TX
RX
Tx
Rx
SPI/I2C
MAX3245
T1IN
R1OUT
MICROCONTROLLER
RST
LDOEN
IRQ
RTS/CLKOUT
CTS
RTS
CTS
T2IN
R2OUT
GPIO0
GPIO1
DTR
DSR
T3IN
R3OUT
GPIO2
GPIO3
DCD
RI
R4OUT
R5OUT
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
50
PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND
PATTERN NO.
24 SSOP A24+1 21-0056 90-0110
24 TQFN-EP T243A3+1 21-0188 90-0122
MAX3107
LOGIC-LEVEL
TRANSLATION
SPI/I2C
TX AND FIFO
LDO
PLL
FLOW
CONTROL
LOGIC-LEVEL
TRANSLATION
REGISTERS
AND
CONTROL
Rx AND FIFO
FRACTIONAL
BAUD-RATE
GENERATOR
GPIO
GPIO0
RX
CTS
GPIO1
GPIO2
GPIO3
CRYSTAL
OSCILLATOR
TX
V18
VA
DGNDAGND
VEXT
VL
LDOEN
I2C/SPI
DIN/A1
DOUT/SDA
CS/A0
SCLK/SCL
RST
IRQ
XIN
XOUT DIVIDER
RTS/CLKOUT
MAX3107 SPI/I2C UART with 128-Word FIFOs
www.maximintegrated.com Maxim Integrated
51
Package Information
For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”,
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing
pertains to the package regardless of RoHS status.
Functional Diagram
REVISION
NUMBER
REVISION
DATE DESCRIPTION PAGES
CHANGED
0 10/09 Initial release
1 4/10
Changed the maximum number for the “External Clock Frequency” specication
from 30MHz to 35MHz in the AC Electrical Characteristics table 8
Replaced the text in the SPI Burst Access section 44
2 4/10 Increased the maximum VIL specication for the XIN Clock Input in the Electrical
Characteristics from 0.2V to 0.3V. 8
3 8/11 Removed internal oscillator and updated register information; V18 capacitor
increased to 1µF; keep supplies powered during shutdown
1, 2, 6, 8,
11–18, 22, 24,
27, 30, 32, 35,
41, 43, 48–51
4 3/14 Removed automotive part from Ordering Information table 1
5 1/15 Replacing automotive references on page 1 1
6 2/15
Added to the Receive and Transmit FIFOs section a note about how the TxFIFOLvl
and RxFIFOLvl values can be in error; added a note to the Transmitter Operation
and Receiver Operation sections about how errors can occur; updated the RHR,
THR, TxFIFOLvl, and RxFIFOLvl register bit descriptions
15, 16, 23, 24, 36
7 5/15 Revised Benets and Features section 1
Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses
are implied. Maxim Integrated reserves the right to change the circuitry and specications without notice at any time. The parametric values (min and max limits)
shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance.
Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.
MAX3107 SPI/I2C UART with 128-Word FIFOs
© 2015 Maxim Integrated Products, Inc.