Panel Mount DataSheet Series 1 120 VAC * Ratings from 10A to 40A @ 24-140 VAC * SCR output for heavy industrial loads * Zero turn-on or instantaneous turn-on outputs * UL/CSA/VDE Approved, CE Compliant to EN60950-1 * Improved SEMS screw and washer * Redesigned housing with anti-rotation barriers * AC or DC control * Direct bond copper substrate * EMC compliant to Level 3 * Direct power lead frame * Epoxy free design For Generation 3 datasheet click here PRODUCT SELECTION Control Voltage 3-32 VDC 90-280 VAC 18-36 VAC 10A 25A 40A D1210 A1210 A1210E D1225 A1225 A1225E D1240 A1240 A1240E AVAILABLE OPTIONS Control Voltage A: 90-280 VAC D: 3-32 VDC AxxxxE: 18-36 VAC 4 A Output Frecuency Blank: 47-440 Hz 4: 400 Hz 12 Overvoltage Protection Blank: Not Included P: Included (8) 10 E Operating Rated Load Current Voltage 10: 10 Amps 12: 24-140 VAC 25: 25 Amps 40: 40 Amps K P Termination Blank: Screw F: Quick Connect (7) (Up to 50 Amps only) K: Hex standoffs (14) G Operating Voltage (47-440Hz) [Vrms] (2) Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] Maximum Load Current [Arms] (4) Minimum Load Current [mArms] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] Minimum Power Factor (at Maximum Load) S H Input Status LED Blank: Not Included G: Included OUTPUT SPECIFICATIONS (1) Description Snubber Blank: Not Included S: Included Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On (9) -10 Thermal Pad Blank: Not Included H: Included Required for valid part number For options only and not required for valid part number * Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. 10A 25A 40A 24-140 600 1 500 10 150 115/120 1.15 1.03 66/60 0.5 24-140 600 1 500 25 150 239/250 1.15 0.8 285/259 0.5 24-140 600 1 500 40 150 597/625 1.15 0.5 1770/1629 0.5 INPUT SPECIFICATIONS (1) Description D12xx Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Minimum Turn-Off Voltage Minimum Input Current [mA] Maximum Input Current [mA] Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 3-32 VDC -32 VDC 3.0 VDC (5) 1.0 VDC 7 12 1/2 Cycle (6) 1/2 Cycle Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. A12xx A12xxE 90-280 Vrms 90 Vrms 10 Vrms 5 10 Current Regulated 20 30 18-36 Vrms 18 Vrms 4 Vrms 16 20 20 30 Panel Mount DataSheet GENERAL SPECIFICATIONS (1) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) 4000 Vrms 109 Ohm 8 pF -40 to 80 C -40 to 125 C 2.6 oz (74.9g) UL 94 V-0 Aluminum 13-15 /1.5-1.7 18-20 / 2.0-2.2 18-20 / 2.0-2.2 w/"K" option 8-10 / 0.9-1.13 85% non-condensing w/"G" option (green) 11,641,553 hours (1,328 years) 7,210,376 hours (823 years) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Baseplate Material Input Terminal Screw Torque Range (in-lbs/Nm) Load Terminal Screw Torque Range (in-lbs/Nm) SSR Mounting Screw Torque Range (in-lbs/Nm) Input/Load Terminal Screw Torque Range (in-lbs/Nm) (14) Humidity LED Input Status Indicator MTBF (Mean Time Between Failures) at 40C ambient temperature (15) MTBF (Mean Time Between Failures) at 60C ambient temperature (15) WIRING DIAGRAM AC OUTPUT 2 ( ) Input 2 Output INPUT 4 (- / ) 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] mm2) 110 [490] 2 x 10 AWG (5.3 / 5.3 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] S O L I D S TAT E R E L AY 4 Wire Pull-Out Strength (lbs)[N] 25 Input Current (mA) 1 Wire Size (Solid / Stranded) Terminals Load (13) 1 ( ) Input Current vs Input Voltage Standard Regulated "DC" Inputs Recommended Wire Sizes V 90 [400] 20 15 10 5 0 0 3 5 10 15 20 25 DC Input Voltage 3 (+ / ) EQUIVALENT CIRCUIT BLOCK DIAGRAMS Diagram: Series 1 AC control AC 4 1 AC AC/DC Converter Current Limiter -DC 4 1 AC (11) Trigger Circuit (10) AC 3 Diagram: Series 1 DC control (10) (12) 2 AC Do not forget to visit us at: www.crydom.com +DC 3 Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. Current Limiter (11) Trigger Circuit (12) 2 AC 30 Panel Mount DataSheet MECHANICAL SPECIFICATIONS (1) Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination 1.1 [27.9] 0.49 [12.4] 1 1.88 [47.6] OUTPUT INPUT 1.1 [27.9] 0.49 [12.4] 0.89 [22.6] Mounting Hole/Slot 0.19 [4.9] DIA. 1 2 S O L I D S TAT E R E L AY 4 Hex Standoff Termination ("K" Option) (14) 2.25 [57.3] 1.7 [43.2] 1.88 [47.6] OUTPUT INPUT 1.58 [40.2] 0.49 [12.4] 1 1.88 [47.6] OUTPUT Faston Terminal(16) 0.25 x 0.032 INPUT 1.40 [35.6] 1.75 [44.5] (4 places) 1.0 [25.4] Quick Connect Termination ("F" Option) - Up to 50 Amp (7) 1.31 [33.4] 1.58 [40.2] Mounting Hole/Slot 0.19 [4.9] DIA. (2 places) 2 S O L I D S TAT E R E L AY 4 0.93 [23.6] (2 places) Quick Connect Termination ("F" Option) - Up to 25 Amp (7) Mounting Hole/Slot 0.19 [4.9] DIA. 3 1.75 [44.5] 1.75 [44.5] 2.25 [57.3] 1.70 [43.2] 1.0 [25.4] 1.0 [25.4] 1.04 [26.4] 2 S O L I D S TAT E R E L AY 4 3 Mounting Hole/Slot 0.19 [4.9] DIA. 2.25 [57.3] 1.88 [47.6] 3 (2 places) 1.25 [31.8] 1.31 [33.4] 0.45 [11.4] (2 places) OUTPUT 2 S O L I D S TAT E R E L AY 4 Faston Terminal(16) 0.187 x 0.020 (4 places) 0.63 [16.0] 1 1.7 [43.2] Faston Terminal(16) 0.25 x 0.032 INPUT 0.49 [12.4] 1.40 [35.6] 1.75 [44.5] 3 Faston Terminal(16) 0.187 x 0.020 (2 places) GENERAL NOTES (1) All parameters at 25C unless otherwise specified. (2) For "S" option, operating voltage frequency is 47-63Hz. (3) For parts with option "S" maximum leakage current is 10mA. (4) Heat sinking required, see derating curves. For "K" option maximum current up to 50 Amp. (5) Increase minimum voltage by 1V for operations from -20 to -40C. (6) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models). (7) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs. (8) Output will self trigger between 450-600Vpk, not suitable for capacitive loads. (9) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. (10) Elective Input Status LED, "G" option. (11) Elective Overvoltage Protection, "P" option. (12) Elective Internal Snubber, "S" option. (13) Load can be wired to either SSR output terminal 1 or 2. (14) Option "K" is intended only for use in attaching a printed circuit board to the SSR or mounting the SSR to a printed circuit board (PCB minimum thickness is 0.031 in) (15) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (16) Mechanical dimensions vary fro m G3 models. For additional information or specific questions, contact Crydom Technical Support. Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. 2.25 [57.3] 1.7 [43.2] 1.25 [31.8] Panel Mount DataSheet SURGE CURRENT INFORMATION 25 A 250 100 200 Surge Current (Amp) Surge Current (Amp) 10 A 120 80 60 40 20 0 0.01 0.1 1 Surge Duration (Secs) 150 100 50 0 0.01 10 0.1 1 Surge Duration (Secs) 10 40 A Surge Current (Amp) 600 500 400 300 200 100 0 0.01 0.1 1 Surge Duration (Secs) 10 Non repetitive peak surge current at Tj initial 40C. THERMAL DERATE INFORMATION 10 A 3C/W 5C/W 25 A 1.5C/W No Heatsink 8 6 4 2 0 2C/W 3C/W 25 Load Current (Amps) Load Current (Amps) 10 20 30 40 50 60 70 Ambient Temperature (C) 20 15 10 5 0 80 20 40 A 1C/W 1.5C/W 2C/W 3.5C/W Load Current (Amps) 40 30 20 10 0 20 30 40 50 60 70 Ambient Temperature (C) Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. 80 30 40 50 60 70 Ambient Temperature (C) 80 Panel Mount DataSheet AGENCY APPROVALS EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge - Level 3 IEC 61000-4-4 : Electrically Fast Transients - Level 3 IEC 61000-4-5 : Electrical Surges - Level 3 IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11ms E116949 LR81689 10143 UG (Not Applicable: -B and 4D) Series 1 has Environmental Product declarations type III conforming to ISO 14025. ACCESORIES Recommended Accessories New Accessories! Protective Cover & Hardware Kits Protective Cover Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Cover Hardware Kit KS101 HK1 HS501DR 5.0 TRM1 HSP-1 HK4 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS202 / HS202DR 2.0 HS201 / HS201DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. Heat Sink Part No. Thermal Resistance Lug Terminal Thermal Pad [C/W] HS053 0.5 HS033 0.36 HS023 0.25 Rev. 112640 Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. Panel Mount DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSI ONE. * Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra * * Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provochera la morte o di lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount DataSheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2014 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)