Data Sheet ACD-16 TRMS-PRO 1000A Data-Logging Clamp-on Multimeter Need the perfect tool to troubleshoot a system? The ACD-16 TRMSPRO provides a full range of measurements, enhanced with data logging capabilities, to catch what the eye can't see. Double the efficiency, with an optional PC interface kit. True RMS for a more accurate signal in a noisy electrical environment. RMS Auto power off Backlight Data hold Measurements: Large, True AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency and Temperature No hassle warranty Data-logging up to 5400 points Optional PC interface capability (RS-232 KIT2) Audible continuity easy to read digital display Accommodates conductors up to 45mm (1.77") in diameter Carrying case, Type k thermocouple, test leads, batteries (installed) and user manual included Voltage overload protection for all functions up to 600V AC/DC No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: $500 MSLP limit) 600V Amprobe(R) Test Tools www.Amprobe.com Data Sheet ACD-16 TRMS-PRO 1000A Data-Logging Clamp-on Multimeter Electrical Specifications: Accuracy is (% reading digits + number of digits) or otherwise specified, at 23 C 5 C & less than 75% R.H. True RMS Models ACD-16 TRMS-PRO ACV & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified. Maximum Crest Factor are as specified below, & with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. Fundamentals are specified at 50Hz and 60Hz. Function AC Voltage 50Hz / 60Hz 45Hz ~ 500Hz 500Hz ~ 3.1kHz 9 CMRR: Input Impedance: True RMS models Crest Factor: DC Voltage NMRR: CMRR: Input Impedance: Resistance Open Circuit Voltage: Audible Continuity Tester Audible threshold: Response time: Frequency Range Accuracy 600.0 V 1.0% + 5d 600.0 V 1.5% + 5d 600.0 V 2.5% + 5d >60dB @ DC to 60Hz, Rs=1kW 2MW, 30pF nominal < 2.3 : 1 at full scale & < 4.6 : 1 at half scale 600.0V >50dB @ 50/60Hz >120dB @ DC, 50/60Hz, Rs=1kW 2MW, 30pF nominal 0.5% + 5d 999.9W 0.4VDC typical 1.0% + 6d between 10W and 300W. 250s 5.00Hz ~ 500.0Hz 0.5%+4d Sensitivity (Sine RMS) 40A range: > 4A 400A range: > 40A 1000A range: > 400A 600V range: > 30V Temperature -50C ~ 300C 2.0% + 3C 1) -58F ~ 572F 2.0% + 6F 1) 1) Add 3C (or 6F) to specified accuracy @ -20C ~ -50C (or @ -4F ~ -58F) Type-K thermocouple range & accuracy not included AC Current (Clamp-on) 50Hz / 60Hz 40.00A, 400.0A, 1000A 1.0% + 5d 1) 2) 3) 45Hz ~500Hz 40.00A, 400.0A 2.0% + 5d 1) 2) 3) 1000A 2.5% + 5d 1) 2) 3) 500Hz ~ 3.1kHz 40.00A, 400.0A 2.0% + 5d 1) 2) 3) 1000A 2.5% + 5d 1) 2) 3) True RMS models Crest Factor: < 2.5 : 1 at full scale & < 5.0 : 1 at half scale for 40.00A & 400.0A ranges < 1.4 : 1 at full scale & < 2.8 : 1 at half scale for 1000A range 1) Add 8d to specified accuracy while reading is below 10% of range 2) Induced error from adjacent current-carrying conductor: < 0.06A/A 3) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening) Amprobe(R) Test Tools www.Amprobe.com ACD-16 TRMS-PRO 1000A Data-Logging Clamp-on Multimeter Data Sheet General Specifications Display: Update: Relative Humidity: Altitude: Storage Temperature: Temperature Coefficient: Sensing: Safety: Transient protection: Pollution degree: E.M.C.: In an RF field of 3V/m: Overload Protections : AC Clamp-on jaws: Power Supply: Power Consumption: Voltage & ACA functions: Ohm & Temperature functions: APO Timing: APO Consumption: Dimension: Weight: Jaw opening & Conductor diameter: Special features: 3-5/6 digits, 6000 counts LCD display 5 per second nominal Maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C Operating below 2000m -20C to 60C, < 80% R.H. (with battery removed) nominal 0.15 x (specified accuracy)/ oC @ (0C -18C or 28C -40C), or otherwise specified True RMS sensing Meets EN61010-1, 201; IEC61010-2-032(1994), EN61010-2 032(1995), UL3111-2-032(1999). Category III 600 Volts AC & DC 6.5kV (1.2/50s surge) 2 Meets EN61326-1 Total Accuracy = Specified Accuracy + 45 digits Performance; above 3V/m is not specified AC 1000A RMS continuous + & COM terminals (all functions): 600VDC/VAC RMS standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2 3.5mA typical 4mA typical Idle for 16 minutes 10A typical L224mm X W78mm X H40mm 224 gm approx 45mm max Display Backlight; Auto-Hold; Display Hold; On screen stand alone Hi-Lo logging (5400 minutes) at sampling speed of faster than: 20 per second for Voltage & ACA functions 4 per second for Ohm & Temperature functions 2 per second for Hz function www.Amprobe.com Data Sheet ACD-16 TRMS-PRO 1000A Data-Logging Clamp-on Multimeters Included Accessories MTL-90B Test leads, TPK-59 banana plug type-K thermocouple, batteries, carrying case and users manual Optional Accessories RS-232 KIT2 ELS2A DKTA-620 and two of TPK-56 TL36A PC Interface kit (PC connection cable with software) Line splitter (Energizer) Dual input Thermocouple adapter with two thermocouples -50F to 600F Heavy duty test leads with threaded alligator clips Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2007 Amprobe Test Tools. All rights reserved. 9/2007 3128800 Rev A Amprobe(R) Test Tools www.Amprobe.com