ELECTRICAL CHARACTERISTICS:
1-1. VOLTAGE RATING...................................115/250VAC
1-2. CURRENT RATING
A. @ 115 VAC..........................................6 A RMS MAX
B. @ 250 VAC.........................................6 A RMS MAX
1-3. OPERATING FREQUENCY......................50/60Hz
1-4. LEAKAGE CURRENT: EACH LINE TO GROUND
A. @ 115 VAC 60Hz............................0.20 mA MAX
B. @ 250 VAC 50Hz.............................0.40 mA MAX
1-5. HIPOT RATING (FOR ONE MINUTE)
A. LINE TO GROUND...........................2250 VDC
B. LINE TO LINE.....................................1450 VDC
1-6. MINIMUM INSERTION LOSS IN dB: (AT 50 OHM SYSTEM)
1-7. OPERATING TEMPERATURE.................-25° TO +85° C
1-8. SAFETY:
1-9. RoHS COMPLIANT
FREQ. MHz
COM. MODE dB
DIF. MODE dB
.05
/
/
.01
/
/
.10
/
/
.15
12
4
.50
18
10
1.0
24
15
5.0
35
35
10
40
40
30
40
40
Qualtek Electronics Corp.
PPC DIVISION
Part Number: 883-06/011
Description: EMI FILTER
Tolerance
+/-
(mm)
Dim
range
(mm)
0-1
1-6
6-18
18-50
50-120
120-250
250-500
0.15
0.20
0.30
0.50
0.70
0.90
1.20
Drawn / Date Checked / Date Approved / Date
B.ZHANG
02-27-02 02-27-02 JJH / 02-27-02
UNIT: mm REV. B
CONTROLLED
APPROVEDDATEDESCRIPTION
REV.
REVISION
B RoHS Compliancy 06-01-06 DP
THESE DRAWINGS ARE THE PROPERTY OF QUALTEK
ELECTRONICS AND NOT TO BE REPRODUCED FOR
OR COMMUNICATED TO A THIRD PARTY WITHOUT
THE EXPRESS WRITTEN PERMISSION OF AN OFFICER
OF QUALTEK ELECTRONICS.
L: 1.05mH
Cx: 0.1uF
Cy: 2200pF
R: 1.0M
1. PHYSICAL DIMENSIONS
2. ELECTRICAL SCHEMATIC
50.0
40.01
28.0
58.0
54.0
Ø3.3 ± 0.1(2X)
3.0
55.0
28.4MAX
PANEL CUTOUT
(MOUNTING FROM FRONT)
40.01 ± 0.1
28.5 ± 0.2
0
M3
55.9 ± 0.2
0
R2.0 51.3
41.0
2.0
LABEL
4.0 46.0