1© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
One world. One KEMET
Benets
Proprietary ferrite material
Flat insertion loss characteristics
Suitable for each countrys power line, including
100 V type
• Operatingtemperaturerangefrom−25°Cto+100°C
• UL94V–0ameretardantratedbase
RoHS compliant
Overview
The KEMET PLT pulse transformers are common mode
choke coils suitable for Power Line Communication (PLC).
Designed with our proprietary ferrite core, they show
excellent insertion loss characteristics.
Applications
PLT-01: 264 VAC maximum power supply line for Power
Line Communication (PLC)
PLT-02: 110 VAC maximum power supply line for Power
Line Communication (PLC)
Pulse Transformers
Device for HD-PLC, PLT Series
Ordering Information
PLT- 01
Series Power Supply Line AC (V)
PLT 01 = 264 V
02 = 110 V
PLT-01 PLT-02
2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Pulse Transformers – Device for HD-PLC, PLT Series
Dimensions – Millimeters
PLT-01
10.0 7.5
7.5
10.0
4 - 1.1φ
1
23
4
Marking
Dimensions - Millimeters Pin Pattern Gauge
Dimensions - Millimeters
Tolerance ±0.1 mm
Circuit Diagram
Lot Number
13.5 Maximum
Part Number
12.5 Maximum
4± 0.7
φ0.6
12.3 Maximum
1 4
32
P S
PLT-02
Dimensions - Millimeters Pin Pattern Gauge
Dimensions - Millimeters
Tolerance ±0.1 mm
Circuit Diagram
1 2
34
P S
7.62
4 - 1.1φ
1
23
4
9.5 Maximum
5.08 7.62
12 Maximum
3 ±0.6
φ0.6
11.5 Maximum
Marking
Part
Number
Lot
Number
5.08
3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Pulse Transformers – Device for HD-PLC, PLT Series
Environmental Compliance
All KEMET Pulse Transformers are RoHS compliant.
Performance Characteristics
Item Performance Characteristics
Rated Current 0.30 Arms
Insulation Resistance 100MΩminimumat500VDC(betweencoilandcoil)
Rated Inductance 7.5 µH minimum
Inductance Measurement Condition 100 kHz, 1 mA
Rated DC Resistance Range 55mΩmaximum
Operating Temperature Range 25°Cto+100°C(includingself-temperaturerise)
Table 1 – Ratings & Part Number Reference
Part
Number
Rated Voltage
AC (V)
Maximum
Rated
Current (A)
ΔT = 25˚C
Inductance
(µH)
Minimum
DC Resistance
(mΩ)
Maximum
Dielectric
Voltage AC1
(V)
Terminal Lead
Diameter
(mm)
Weight
(g)
PLT-01 264 0.3 7.5 55 3,600 φ0.6 1.8
PLT-02 110 0.3 7.5 55 1,200 φ0.6 1.3
1 Two seconds, between coil and coil, no abnormality.
4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Pulse Transformers – Device for HD-PLC, PLT Series
Insertion Loss Characteristics
Measuring Circuit
Meter
50Ω
SMA Cable
(50Ω)
Universal Board
(Calibration Point)
Universal Board
(Calibration Point)
N1 N2
SMA Cable
(50Ω)
Frequency (MHz)
PLT-01
0.0
2.0
4.0
6.0
8.0
10.0
0.1 1 10 100
Insertion Loss (dB)
PLT-02
Frequency (MHz)
0.0
2.0
4.0
6.0
8.0
10.0
0.1 1 10 100
Insertion Loss (dB)
Impedance Characteristics
PLT-01
Frequency (MHz)
0.001
10,000
1,000
100
10
1
0.1
0.01 0.1 1 10 100
Impedance (Ω)
PLT-02
Frequency (MHz)
Impedance (Ω)
0.001
10,000
1,000
100
10
1
0.1
0.01 0.1 1 10 100
5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Pulse Transformers – Device for HD-PLC, PLT Series
Packaging
Part Number Packaging Type Pieces per Box
PLT-01 Bulk 280
PLT-02 Bulk 900
Handling Precautions
Precautions for product storage
Pulse Transformers should be stored in normal working environments. While the transformers themselves are quite
robust in other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive
atmospheres, and long term storage.
KEMETrecommendsthatmaximumstoragetemperaturenotexceed40°Candmaximumstoragehumiditynotexceed70%
relativehumidity.Atmospheresshouldbefreeofchlorineandsulfurbearingcompounds.Temperatureuctuationsshould
beminimizedtoavoidcondensationontheparts.Avoidalsostoragenearstrongmagneticeldsasthismightmagnetize
the product.
For optimized solderability Transformers stock should be used promptly, preferably within six months of receipt.
Product temperature rise values
The values listed for temperature rise are the result of self-heating in wires when the rated current is applied. Check and
evaluate the value of the core temperature rise under actual operating conditions when using.
Export Control
For customers in Japan
For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export
licensespeciedbythelawisrequiredforexport.
For customers outside Japan
Pulse Transformers should not be used or sold for use in the development, production, stockpiling or utilization of any
conventional weapons or mass-destructive weapons (nuclear weapons, chemical or biological weapons or missiles) or any
other weapons.
6© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard TF0001_PLT 5/2/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Pulse Transformers – Device for HD-PLC, PLT Series
KEMET Electronics Corporation Sales Offi ces
Foracompletelistofourglobalsalesoffices,pleasevisitwww.kemet.com/sales.
Disclaimer
Allproductspecications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsiblefor
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET) knowledge of typical operating conditions for such
applications,butarenotintendedtoconstitute–andKEMETspecicallydisclaims–anywarrantyconcerningsuitabilityforaspeciccustomerapplicationoruse.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes
no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury
or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.