Features
GDT/TBU® High-Speed Protector technology
Low impulse let-through
High surge current rating
Available in isolated and grounded versions
10/100/1000 data compatibility
5 kV isolation
Listed per UL 497B (File: E153537)
Applications
Data communications
Highly exposed Ethernet
1000 Base-T Gigabit Ethernet
Indoor/controlled environment installations
Telecommunications and industrial
installations
1500 Series Gigabit Ethernet SPD
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
The 1500 Series Ethernet Surge Protective Device (SPD) incorporates multiple Bourns® circuit protection technologies. These technologies
are designed to work together to provide an unmatched level of surge protection for exposed Ethernet applications. The 1500 Series is
designed to meet key surge and AC power cross requirements of GR-1089-Core Issue 6. The isolated model is designed to withstand
voltages up to 5 kV.
The 1500 Series is available as a wall mount unit with optional DIN Rail hardware.
Characteristics
Test methods per UL 497B, GR-1089 Issue 6, and CSA C22.2.
Parameter Isolated Version Grounded Version
DC Breakdown Line to Line 150 V Typical Input / 7 V Typical Output
DC Breakdown Line to Ground N/A 150 V Typ.
Line Series Resistance (Loop) 12 Ω Typ.
Line Series Balance 0.5 Ω Typ. / 1.0 Ω Max
Capacitance Line to Line @ 1 MHz N/A 10 pF Typ.
Time-to-block (tblock) <1 μs
First Level Surge
1 kV – 10/1000 μs, 100 A
2.5 kV – 2/10 μs, 500 A
800 V – 1.2/50 μs, 8/20 μs Combo Wave
>10 operations
>10 operations
>10 operations
Second Level Surge
2.5 kV – 2/10 μs, 500 A, Inductive Kick
6 kV / 3 kA – 1.2/50 μs, 8/20 μs Combo Wave
> 1 operation
> 1 operation
First Level Power Fault
220 mA Below Protection Threshold
600 V / 1 A / 1 Second
1000 V / 1 A / 1 Second
425 V / 0.5 A / 4 Seconds
15 minutes
> 60 operations
> 60 operations
> 1 operation
Second Level Power Fault
120 V / 25 A 1
425 V / 40 A / 1.5 Second 1
425 V / 7 A / 5 Seconds 1
425 V / 2.2 A
15 minutes
1 operation
1 operation
15 minutes
BER Performance Testing
10/100 Mbps
1 Gbps
> 100 meters
Up to 100 meters
Storage and Operating Temperature -40 to +65 °C
Ground Connection Screw Lug or DIN Rail Clip
Notes:
Isolated version does not require a ground connection.
1) Fuse may fail open and disconnect from circuit.
Asia-Pacifi c: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
Product Dimensions
How To Order
DIMENSIONS: MM
(INCHES)
1500 - X Y - W
Model Number Designator
Confi guration
1 = Isolated*
2 = Grounded
Hardware Options
S = Screw Lug
D = DIN Rail
Ground Wire (Optional)
W = #14 AWG Ground Wire, 3 Ft.
* Isolated unit requires no ground.
DIN Rail Hardware Dimensions
65.10
(2.563)
25.12
(0.989)
107.01
(4.213)
15.75
(0.62)
40.64
(1.60)
16.25
(0.65)
46.48
(1.83)
REV. C 04/15
“Bourns” is a registered trademark of Bourns, Inc. in the United States and other countries.
“TBU” is a registered trademark of Bourns, Inc. in the U.S. and other countries, except Japan. All references to TBU® in this document for use in Japan shall be deemed to be replaced
with Bourns® TBU™.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
1500 Series Gigabit Ethernet SPD
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Bourns:
1500-1S 1500-2D 1500-2D-W 1500-2S-W 1500-1D