MP Series
• SIP SSR
• Ratings to 4A @ 280 VAC or 3A @ 60 VDC
• Triac (AC) or Transistor (DC) output
• DC Control
• Normally open (AC or DC) or normally closed output (DC only)
• CE Compliant to EN60950-1
PRODUCT SELECTION
Control Voltage 3A 3A 4A 3A
3-32 VDC MP120D3 MP240D3 MP240D4 MPDCD3
AVAILABLE OPTIONS
AC OUTPUT SPECIFICATIONS (1)
Description MP120D3 MP240D3 MP240D4
Operating Voltage (47-63Hz) [Vrms] 12-140 24-280 24-280
Transient Overvoltage [Vpk] 400 600 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 5 5 5
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 200 200 200
Maximum Load Current [Arms] 3 3 4
Minimum Load Current [Arms] 0.02 0.02 0.02
Maximum Surge Current (16.6ms) [Apk] 90 90 130
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6
Maximum I²t for fusing (8.3 msec) [A² sec] 36 36 72
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
DC OUTPUT SPECIFICATIONS (1)
Description MPDCD3
Operating Voltage Range [VDC] 3-60
Maximum Load Current [Arms] 3
Minimum Load Current [Arms] 0.02
Maximum Surge Current for 1 second [Adc] 5
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.5
Maximum Off-State Leakage Current @ Rated Voltage [mA] 1.0