1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 1 RoHS Ready SOLARLOK Interconnection System OBSOLETE NOT the LATEST REVISION 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 2 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Table of Contents The SOLARLOK Concept .................................................... 1 Large Junction Box - Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Large Junction Box - Parallel Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium Junction Box - Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Small Junction Box - Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mini Junction Box - Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 T-Branch Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DC/AC Converter Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 AC Inverter Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Solar Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Solar Cable, 1-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Field Wiring, Switching and Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Wiring Example with Extension Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SolKlipTM - Ground Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Interconnection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Application Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Assembly and Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Restriction on the Use of Hazardous Substances (RoHS) . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Engineering Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Product Information Center (PIC) Tyco Electronics Online Our PIC team are there to help with any further questions. With our experienced employees in the Product Information Center (PIC) we can offer you a reliable source of information and support for your technical queries. Internet Homepage: www.tycoelectronics.com To contact your local Tyco Electronics subsidiary, please refer to the address page at the back of this catalog. Electronic Internet Catalog: http://catalog.tycoelectronics.com Product und Machine Literature Order quickly and easily by fax: For Fax No. see address page entry for your specific region. Our website is more than an Internet guide. It is constantly being added to and is an innovative and interactive source for applications tips, product updates and technical information of all types. With our innovative StepSearch software, which has been perfected over a period of several years you can conveniently surf your way through all our products. A large product range has extensive product literature. You can request flyers, catalogs and brochures for each of the product sectors of relevance to you. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 1 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 The SOLARLOK Concept System Features Junction Box Variable wiring options Easily accessible Simple, fast and cost-effective assembly Flat, low profile design High current carrying capacity Good thermal balance Connectorized or direct wire configurations Up to four outputs possible Up to six internal rails Customer-specific solutions TUV and UL approved Connector Simple on-site processing Mating safety provided by keyed housings Semi-automatic assembly capability possible Multiple plugging and unplugging cycles Accomodates solar cable with different insulation diameters High current carrying capacity Wide temperature operating range TUV and UL approved Solar Cable Dual wall insulation Electron beam cross-linked Excellent resistance to U.V., water, ozone, fluids, salt, general weathering Excellent resistance to abrasion Halogen free, flame retardant, low toxicity Very low smoke emissions Excellent flexibility and stripping performance Different cable diameters Operating Temperature from -40 C up to +120 C Voltage Rating up to 2600 V DC IEC 60228 Class 5 (stranded tin plated copper and flexible) TUV certified acc. to 2Pfg 1169/08.2007 UL certified Simple and Reliable System Interconnection of Individual Solar Modules Right to the DC/AC Converters Tyco Electronics will be contributing to the establishment of this environmentally-friendly technology with the introduction of its SOLARLOK connector system. Market expansion of the formerly regulated energy supply sector, increased global environmental awareness and governments committing themselves to more stringent environmental targets have opened up new opportunities for the photovoltaic industry. SOLARLOK delivers a flexible system solution for easy and reliable interconnections from photovoltaic modules to the DC/AC converter. The entire system concept is based on costeffective and reliable processing of individual interconnection system components. This significantly reduces installation costs of the solar energy system. Having served a niche market in the past, the photovoltaics industry now has the opportunity to move into mass production, realizing economies of scale and gaining a greater market share of the world's energy mix. The junction box concept is based on a flexible, open system structure, which allows serial as well as parallel interconnection via direct wire connect or separable connectors. Within the junc-tion box, up to six termination places rails are available for photovoltaic foil connection. All specifications subject to change. Consult Tyco Electronics for latest specifications. The male and female cable coupler was designed for high voltage and high current-carrying capacity in addition to the wellestablished IP 67 sealing requirement in the photovoltaic industry. Mating safety is provided by polarity keyed housings, fully shrouded contacts, reliable high cycle life, and squeeze to release connection system. In addition, a wide temperature range and fulfillment of worldwide standards for photovoltaic connection systems complement the robust product specification. The design of the male and female receptacle for the junction box and the DC/AC converter follow the cable coupler "click philosophy" for quick and secure mating even in difficult mounting positions. If required by the customer, the junction box can be delivered pre-configured with diodes, jumpers, plug connectors, and solar cable pigtails. 1 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 2 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 150 mm Large Junction Box - Serial Interconnection W: 150 mm H: 25 mm SERIAL INTERCONNECTION Interconnection Options Configuration Part Number Package Quantity Plug Connector Plus Keyed 2 Direct Wire Contact Rails 1-1394723-6 20 oo oooooo 2-1394723-6 20 oo oooooo 0-1394723-4 20 oo oooooo 0-1394723-3 20 o Diodes Minus Keyed o All specifications subject to change. Consult Tyco Electronics for latest specifications. oooooo oooo 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 3 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 150 mm Large Junction Box - Parallel Interconnection W: 150 mm H: 25 mm PA R A L L E L I N T E R C O N N E C T I O N Interconnection Options Configuration Part Number Package Quantity Plug Connector Direct Wire Plus Keyed Minus Keyed o o Contact Rails 1394723-5 20 1394723-6 20 oooo oooooo 1394723-9 20 oooo oooooo Diodes oooooo All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 4 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 135 mm Medium Junction Box - Serial Interconnection W: 115 mm H: 22.5 mm SERIAL INTERCONNECTION Interconnection Options Configuration Part Number Package Quantity Plug Connector Plus Keyed 4 Direct Wire Contact Rails Diodes Minus Keyed 1740699-1 60 oo oooo ooo SL1010 1740699-6 35 oo oooo ooo SL1010 1740700-1 60 o o oooo ooo SL1010 1740700-3 35 o o oooo ooo SL1010 1740971-1 60 oo oooo ooo SL1515 1740971-2 35 oo oooo ooo SL1515 1740972-1 60 o o oooo ooo SL1515 1740972-3 35 o o oooo ooo SL1515 ) Junction Box Assembly with two 100 cm long 4.0 mm2 black solar cable and plug connector. ) Junction Box Assembly with one 200 cm long 4.0 mm2 black solar cable and two plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 5 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 135 mm Medium Junction Box - Serial Interconnection (continued) W: 115 mm H: 22.5 mm SERIAL INTERCONNECTION Interconnection Options Configuration Part Number Package Quantity Plug Connector Plus Keyed 0-1740657-7 Direct Wire Contact Rails Diodes oooo ooo SL1010 ooo SL1515 oooo ooo SL1010 ooo SL1515 Minus Keyed 60 oo 0-1740657-8 35 0-1740658-1 60 o o oooo ooo SL1010 ooo SL1515 0-1740658-3 35 o o oooo ooo SL1010 ooo SL1515 0-1740657-9 60 oo oooo ooo SL1515 1-1740657-0 35 oo oooo ooo SL1515 0-1740658-4 60 o o oooo ooo SL1515 0-1740658-5 35 o o oooo ooo SL1515 oo ) Junction Box Assembly with two 100 cm long 4.0 mm2 black solar cable and plug connector. ) Junction Box Assembly with one 200 cm long 4.0 mm2 black solar cable and two plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 6 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 138 mm Small Junction Box - Serial Interconnection W: 90 mm H: 22 mm SERIAL INTERCONNECTION Interconnection Options Configuration Part Number Package Quantity Plug Connector Plus Keyed 6 Direct Wire Contact Rails Diodes Minus Keyed 1740220-4 80 oo ooo 1740220-2 80 oo ooo oo 1740425-3 48 oo ooo oo 1740220-3 80 oo ooo 1740220-1 80 oo ooo oo 1740425-1 48 oo ooo oo ) Junction Box Assembly with two 70 cm long 4.0 mm2 black solar cable and plug connector. ) Junction Box Assembly with two 85 cm long 4.0 mm2 black solar cable and plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 7 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 138 mm Small Junction Box - Serial Interconnection (continued) W: 90 mm H: 22 mm SERIAL INTERCONNECTION Interconnection Options Configuration Part Number Package Quantity Plug Connector Direct Wire Plus Keyed Minus Keyed Contact Rails Diodes 0-1418867-2 80 o o ooo 0-1418867-5 80 o o ooo oo 1-1418867-3 48 o o ooo oo 0-1418867-1 80 o o ooo 0-1418867-6 80 o o ooo oo 1-1418867-2 48 o o ooo oo ) Junction Box Assembly with one 140 cm long 4.0 mm2 black solar cable and two plug connectors. ) Junction Box Assembly with one 170 cm long 4.0 mm2 black solar cable and two plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 8 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 D: 111 mm Mini Junction Box - Serial Interconnection W: 76 mm H: 19 mm SERIAL INTERCONNECTION Configuration ) 8 Part Number Package Quantity Contact Rail Shape Direct Wire Contact Rails Diodes 1740863-1 80 Straight oo oo o 1740863-2 80 Right-Angle oo oo o Junction Box Assembly with two 85 cm long 4.0 mm2 black solar cable and plug connector. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 9 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Cable Coupler Wire Size (mm2 ) Female Cable Coupler Male Cable Coupler Package Quantity Plus Keyed Minus Keyed Plus Keyed Minus Keyed 2.5 0-1394462-1 0-1394462-2 0-1394461-1 0-1394461-2 100 4.0 0-1394462-3 0-1394462-4 0-1394461-3 0-1394461-4 100 6.0 5-1394462-5 5-1394462-6 6-1394461-5 6-1394461-6 100 Male Cable Coupler Not Keyed, only for Junction Box Serial Interconnection Wire Size (mm2 ) Male Cable Coupler Package Quantity 2.5 6-1394461-1 100 4.0 6-1394461-2 100 6.0 6-1394461-4 100 Cable Coupler with Connector Latch Locking Clip Connector Latch Locking Clip Package Quantity 0-1534226-1 100 All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 10 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 T-Branch Connector Parallel Interconnection using T-Branch Connector (Male-to-Male) T-Branch Connector Plus Keyed Part Number Package Quantity 1534611-1 20 1534611-2 20 Part Number Package Quantity 1740277-1 20 1740277-2 20 Minus Keyed o o Parallel Interconnection using T-Branch Connector (Female-to-Male) T-Branch Connector Plus Keyed Minus Keyed o o 10 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 11 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 DC/AC Converter Receptacle O-Ring and Metal Nut Flat Seal and Plastic Nut Wire Size 2 2.5 mm (AWG 14) Keying 2 4.0 mm (AWG 12) o Plus o o o o o o o o o o o o o o o o o o 1394738-1 100 1394738-2 100 1394738-3 100 1394738-4 100 1740210-1 100 Remarks O-Ring and Metal Nut 1740210-2 100 1740210-3 100 1740210-4 100 1740210-7 100 Flat Seal and Plastic Nut - Black Flat Seal and Plastic Nut - Red 1740210-8 100 Flat Seal and Plastic Nut - Blue 100 Flat Seal and Plastic Nut - Red o 1-1740210-0-0 100 Flat Seal and Plastic Nut - Blue o 1394739-1 100 Cover o o Package Quantity 1740210-9 o o Part Number Minus o o o With Cover All specifications subject to change. Consult Tyco Electronics for latest specifications. 11 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 12 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 AC Inverter Connector Product Facts Current Rating: 30 A Voltage Rating: 400 V Protection Degree: IP67 (mated) No. of Positions: 5 Poles Temperature Range: -40 C up to +50 C Wire Size Range: 2.5-6.0 mm2 Approvals: * VDE certified * UL pending 12 Configuration 5 Pole Cable Length 200 mm (5 x 4 mm2 ) Metall Nut Receptacle o o o Receptacle o o Header o Assembly o o Assembly o o Plastic Nut o o o All specifications subject to change. Consult Tyco Electronics for latest specifications. Part Number Package Quantity 1740483-1 24 1740483-2 24 1740479-1 24 1740493-1 24 1740493-2 24 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 13 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Solar Cable Product Facts Dual wall insulation Electron beam cross-linked Excellent resistance to UV, water, ozone, fluids, salt, general weathering Excellent resistance to abrasion Halogen free, flame retardant, low toxicity Very low smoke emissions Excellent flexibility and stripping performance Wire size from 2.5 mm2 up to 6.0 mm2 As part of expanding the SOLARLOK Product Line, Tyco Electronics has specified a wire that is designed to meet the harsh environmental conditions typical in the wiring of photovoltaic installations. The flexible, dual wall, halogen free and cross linked solar wire offers long term stability and TUV approval. Standards Material and Finish Mechanical Features Electrical Features Approval: * IEC 60228 Class 5 (stranded tin plated copper and flexible); * TUV certified acc. to 2Pfg 1169/08.2007 Conductor: Stranded tin plated copper Max. Conductor Temperature Continuous: +120 C At Short Circuit: +250 C Voltage Rating UO /U: 1800/3000 V AC / 2600 V DC Insulation: Electron beam cross-linked Polyolefin Sheath: Electron beam cross-linked halogen free Polyolefin Color: Black, blue, red Its outstanding features include: high resistance against environmental conditions like humidity, UV-radiation and ozone. Min. Operating Temperature Free Installation: -25 C Fixed Installation: -40 C Wire Size Range: 2.5 mm2 (AWG 14), 4.0 mm2 (AWG 12), 6.0 mm2 (AWG 10) In addition, it has excellent resistance to abrasion and temperature extremes. The wire has a high dielectric withstand voltage and with its fine-stranded, tin plated copper conductor, it is easy to handle and to strip. Test Voltage for 5 Minutes: 6000 V Max. Current Carrying Capacity (Free in Air): 36 A up to 116 A (size dependent) Min. Bending Radius: 5 x cable wire diameter, fixed installation All specifications subject to change. Consult Tyco Electronics for latest specifications. 13 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 14 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Solar Cable, 1-Pole Tyco Electronics Solar Cable, 1-Pole TUV approved UL approved Wire Size Range (mm2 ) Outer Diameter Package Quantity Color (AWG) (mm) (Inch) Black 2.5 - 5.1 0.20 Red Blue Black 4.0 - 5.7 0.22 Red Blue Black 6.0 - 6.2 0.24 Red Blue Wire Size Range (mm) (Inch) - 14 - 0.17 - 12 10 - - 0.19 0.21 (m) (Feet) TUV 500 - o 1-956297-4 100 - o 0-956297-5 500 - o 1-956297-5 100 - o 0-956297-6 500 - o 1-956297-6 100 - o 0-956298-4 500 - o 1-956298-4 100 - o 0-956298-5 500 - o 1-956298-5 100 - o 0-956298-6 500 - o 1-956298-6 100 - o 0-956299-4 500 - o 1-956299-4 100 - o 0-956299-5 500 - o 1-956299-5 100 - o 0-956299-6 500 - o 1-956299-6 100 - o Package Quantity Color (AWG) - 0-956297-4 Outer Diameter (mm2) Black Black Black Approbation Part Number (m) (Feet) UL -1986166-2 - 500 o -1986166-3 - 2500 o -1986165-2 - 500 o -1986165-3 - 1500 o -1986164-2 - 500 o -1986164-3 - 1000 o ) Technical Data upon request. 14 Approbation Part Number All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 15 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Field Wiring, Switching and Protection Product Features Switching Collecting Protecting 1 to 10 strings input Cable cross section up to 10 mm2 SOLARLOK connectors Various cable glands Current up to 80 A DC Voltage up to 1000 V DC Lightning protection Modular product concept One- / two-pole switches Current up to 80 A DC Voltage up to 1000 VDC Compact, standardized design Proven quality One- / two-pole switch Main switch function Lockable Current up to 63 A DC Voltage up to 900 V Uoc Your Solution The photovoltaic integrator looks for best fit solutions to wire various types and sizes of solar generators. The new product concept from Tyco Electronics provides this flexibility to photovoltaic integrators. The modular product can be comprised of a switch, lightning protection, fuses or any combination of these or other commonly available components. We can customize a product to fit your specific application. Please contact us with your requirements. All specifications subject to change. Consult Tyco Electronics for latest specifications. 15 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 16 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Wiring Example with Extension Cables 2 3 Clearance (e.g. Roof Window) 2 2 1 1 Male Cable Coupler (+) 1394461-3 Female Cable Coupler (+) 1394462-3 2 Male Cable Coupler (-) 1394461-4 Female Cable Coupler (-) 1394462-4 3 Female Cable Coupler (+) 1394462-3 Female Cable Coupler (+) 1394462-3 Inverter Configuration Example at 4.0 mm2. Cable Assembly Wire Size: 4.0 mm2 Color: Black Part Numbers for Cable Length Cable Assembly Version 1m 3m 5m 10 m 20 m 1 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 2 1-1987376-1 1-1987376-2 1-1987376-3 1-1987376-4 1-1987376-5 3 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 More variants (cable length, wire diameter, color) upon request. 16 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 17 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Wiring Example with Extension Cables (continued) 5 5 3 Clearance (e.g. Roof Window) 4 2 1 1 Male Cable Coupler (+) 1394461-3 Female Cable Coupler (+) 1394462-3 2 Male Cable Coupler (-) 1394461-4 Female Cable Coupler (-) 1394462-4 3 Female Cable Coupler (+) 1394462-3 Female Cable Coupler (+) 1394462-3 4 Female Cable Coupler (-) 1394462-4 Female Cable Coupler (-) 1394462-4 5 Female Cable Coupler (-) 1394462-4 Female Cable Coupler (+) 1394462-3 Inverter Configuration Example at 4.0 mm2. Cable Assembly Wire Size: 4.0 mm2 Color: Black Part Numbers for Cable Length Cable Assembly Version 1m 3m 5m 10 m 20 m 1 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 2 1-1987376-1 1-1987376-2 1-1987376-3 1-1987376-4 1-1987376-5 3 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 4 3-1987376-1 3-1987376-2 3-1987376-3 3-1987376-4 3-1987376-5 5 4-1987376-1 4-1987376-2 4-1987376-3 4-1987376-4 4-1987376-5 More variants (cable length, wire diameter, color) upon request. All specifications subject to change. Consult Tyco Electronics for latest specifications. 17 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 18 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 SolKlipTM - Ground Clip Product Features Self-tapping screw Quick and easy mounting Four-point contact to wire Low interface resistance Toolless termination Re-terminateable up to 5 times UV resistant Weather-proof UL approved RoHS compliant Tyco Electronics' newest innovation provides the photovoltaic integrator with a solution for grounding PV panels and mounting frames. The Tyco Electronics SolKlip brings a new ground connection solution to the market by the utilizing well-known insulation displacement termination technology. Existing solutions typically require the use of ring tongue crimp terminals which have to be crimped first at a specific location on the wire, a hole is then drilled into the mounting surface, and the product is finally mounted on the frame with a separate thread forming or self-tapping screw. The new Tyco Electronics SolKlip provides an extremely simplified solution for terminating a continuous-run ground wire. 18 Termination times are measured in seconds using the pre-mounted Tyco Electronics SolKlip thereby saving time and reducing wiring costs substantially. The four-point wire contact inherent in the design optimizes grounding performance and provides protection against contact problems due to its low interface resistance. The Tyco Electronics SolKlip can be used with un-insulated copper wires from 12 AWG to 10 AWG. The retained-force nature of the contact provides a robust interface that minimizes vibration or thermally induced termination problems that often occur with traditional ground-screw connections. Termination of the wire is safely and easily accomplished toollessly by simply inserting the wire and closing the cover. All specifications subject to change. Consult Tyco Electronics for latest specifications. With a tensile strength of up to 36 kg, the UV-resistant enclosure provides a secure termination even in roughest environmental and assembly conditions. As an added benefit, the connection can be opened and re-terminated again up to five times. Retrofitting the Tyco Electronics SolKlip on panels or frames can be done at any time by simply by drilling mounting hole in the frame and attaching the terminal to the frame using the integrated, self-tapping screw. This ensures a secure connection with the panel and/or frame. The patent-pending Tyco Electronics SolKlip ground terminal supplements the existing Tyco Electronics SOLARLOK product portfolio and offers the electrician yet another valuable component for simple and fast wiring of a PV-system. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 19 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 SolKlipTM - Ground Clip (continued) 3 Easy Steps to Ground Your PV System - + - + - + Yesterday * * * * Insert ... - + ... Push ... ... Ready! - + * Screwdriver * Drill * Pliers - + Today Click Screw Washer Lock Washer Ring Tongue * SolKlip Click Click Description Electrical Standards and Specifications Mechanical SolKlip ground clips are designed for solar panel grounding applications using solid un-insulated copper 10 AWG and 12 AWG. The electrical performance of this product will meet the tough requirements of photovoltaic grounding applications. SolKlip Grounding Clip: UL 467 pending, a requirement for UL 1703 solar panel listing. The mechanical properties of this product will meet the tough requirements for grounding applications layed down in the UL requirements. Applications Product Offering & Dimensions Solar panels and related products that require grounding for safety reasons. SolKlip for Solar Grounding Part No. 1954381-1 to handle 12-10 AWG solid, un-insulated ground wire. Applications include: wire jumpers between solar panels, solar roof tiles and between panels and the AC/DC inverters. Application Tooling UL 486A-B pending, also a requirement as part of the UL 1703 approval listing. Materials Housing: Durable PPT Contact: High conductivity copper alloy No special tooling required. All specifications subject to change. Consult Tyco Electronics for latest specifications. 19 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 20 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Interconnection Examples Serial Interconnection for Junction Boxes with Cable Glands (4.0 mm2 Wiring) 1394462-4 6-1394461-2 1394461-4 1394462-3 1394462-4 1394462-3 1394738-4 1394738-3 DC/AC Converter 20 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 21 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Interconnection Examples (continued) Serial Interconnection for Junction Boxes with Plug Connectors (4.0 mm2 Wiring) 1394462-4 1394462-3 1394462-3 1394462-4 1394462-4 1394462-3 1394738-4 1394738-3 DC/AC Converter All specifications subject to change. Consult Tyco Electronics for latest specifications. 21 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 22 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Application Tooling Cable Assembly Tooling Hand Crimping Tool incl. Vario Crimp Head and Locator Part Numbers 1-1579004-1 (1.5 + 2.5 mm2) 1-1579004-2 (4.0 + 6.0 mm2) Vario Crimp Head 7-1579001-8 (1.5 + 2.5 mm2) 7-1579001-9 (4.0 + 6.0 mm2) Hand Crimping Tool incl. Vario Crimp Head and Locator Part No. 1579004-8 (for 1.5 + 2.5 + 4.0 + 6.0 mm2) Die Set Part No. 6-1579001-6 (for 1.5 + 2.5 + 4.0 + 6.0 mm2) Extraction Tool suitable for all wire sizes Part No. 1102855-3 Insulation Stripper includes length stop for all wire sizes: 1.5 mm2, 2.5 mm2, 4.0 mm2 and 6.0 mm2. Suitable for Tyco Electronics Solar Cable. Part No. 4-1579002-2 SOLARLOK Electric Terminator CS 200 Adapter for Vario Crimp Head: Part No. 1579000-4 Base Machine: Part No. 539630-1 Vario Crimp Head (1.5 and 2.5 mm2): Part No. 7-1579001-8 Vario Crimp Head (4.0 and 6.0 mm2): Part No. 7-1579001-9 Vario Crimp Head (AWG 10): Part No. 8-1579001-2 Vario Crimp Head (AWG 12): Part No. 5-1579001-5 Vario Crimpkopf (AWG 14): Part No. 5-1579001-4 22 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 23 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Application Tooling (continued) Wire Spring Clamp Tool Junction Box Assembly Tooling Part No. 1579007-2 Dioden / Jumper Spring Clamp Tool Part No. 1579007-5 Foil Spring Clamp Tool Part No. 1579007-3 Large Box Part No. 1740969-1 Medium Box Part No. 1740969-2 Small Box Field Service Kit Kit includes the following parts: Part No. 1534858-1 (Metric Wire) All specifications subject to change. Consult Tyco Electronics for latest specifications. 100 Cable Coupler (Housings, Plus and Minus coded) Crimp Contacts (4.0 and 6.0 mm2) Strain Relief Seals Hand Crimp Tool: Part No. 1-1579004-2 Extraction Tool: Part No. 1102855-3 Insulation Stripper: Part No. 4-1579002-2 23 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 24 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines Table of Contents Page SOLARLOK Plug Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1. General Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2. Termination of the Cable Wires / Crimping of the Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3. Handling of the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.1 Selection of Sealing Grommet for Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.2 Connector Latching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.3 Disconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 DC/AC Converter Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4. Application Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6. Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 SOLARLOK Plug Connector Attention: This connector is to be used only to interconnect firmly fixed cables. Do not disconnect under load. Current path should only be disconnected using approved disconnect devices. Cable assemblies shall be labeled with Part No. 1394470-1. To protect against shock, ensure that conductors and their associated connectors are separated from opposite polarity components. 1. General Comments Any kind of pollution (dust, oil, humidity, etc.) during the assembly process or to the unmated connector can degrade contact and connector performance. This applies in particular to the seals and the crimping of the contacts. A clean assembly environment is therefore essential. 2. Termination of the Cable Wires and Crimping of the Contacts SOLARLOK connectors use different crimp contacts for various wire gauges. Possible wire gauges are 1.5 mm2, 2.5 mm2, 4.0 mm2, 5.3 mm2 und 6.0 mm2 resp. AWG 16, AWG 14, AWG 12 and AWG 10. The tools to be used are selected based upon the wire gauge. For the application specification, please refer to specification # 114-74013. 3.1 Handling of the Connectors 3.1 Selection of 3.1 Sealing Grommet 3.1 for Cable Connectors Use only appropriate wire gauges. Besides the standard seal/pinch ring combination further five different seals are available. 4.0 mm grommet inner diameter (for insulation diameter from 3.2 to 4.3 mm), Part No. 1394465-5 5.0 mm grommet inner diameter (for insulation diameter from 4.3 to 5.3 mm), Part No. 1394465-1 6.0 mm grommet inner diameter (for insulation diameter from 5.3 to 6.2 mm), Part No. 1394465-2 7.0 mm grommet inner diameter (for insulation diameter from 6.2 to 7.2 mm), Part No. 1394465-3 8.0 mm grommet inner diameter (for insulation diameter from 7.2 to 8.0 mm), Part No. 1394465-4 The grommet has to be matched with the outer diameter of the solar cable (see customer drawing, Part No. 1394461 and Part No. 1394462) and the pinch ring (Part No. 1418677-2) must be applied. 24 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 25 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) When assembling the connectors, the following sequence must be followed: 1 Stripping the Wire (please refer to application specification # 114-74013) 8,0 mm Fig. 1 2 Insert the stripped wire into the wire crimp barrel until it stops. While holding the wire in place, squeeze tool handles together until ratchet releases. Fig. 2 3 Place seal/pinch ring combination into the connector housing until it stops. Fig. 3 4 Place backshell onto the connector housing. Fig. 4 5 Push contact with cable into the connector housing until you hear the contact is locked into position Fig. 5 6 Tighten backshell nut to 1.5 Nm Fig. 6 All specifications subject to change. Consult Tyco Electronics for latest specifications. 25 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 26 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 3.2 Connector Latching When mating the SOLARLOK connectors, ensure the following: Connectors labeled with a plus or minus are keyed and can only be mated to similarly marked and keyed connectors. CAUTION: The "neutral" designated pin connectors incorporate no keying features and must only be used for Serial Interconnection of Photovoltaic Modules. The neutral product should not be used where maintaining polarity is critical. The polarity of the "neutral" connector must labeled with Part No. 1394725-1 or Part No. 1394725-2 nearby the connector. The connector system is fully latched only when the latches are flush with the mating connector. After the connector is fully latched, the optional latch locking clip may be snapped into place. Fig. 7 (Female Connector) 3.3 Disconnecting C A U T I O N : This connector must not be disconnected under load. Disconnect circuit from load before unplugging connectors. Cable assemblies should be labeled using Tyco Electronics Label, Part No. 1394470-1. Unmating of the connector CAUTION: Do not disconnect the connector under load! 1 2 1 1 The locking mechanism is opened by depressing the latches. 2 Pull out the connectors. While depressing the latches, disconnect the connector by pulling the connector halves apart. 26 All specifications subject to change. Consult Tyco Electronics for latest specifications. Fig. 8 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 27 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 3.4 DC/AC Converter Receptacle 1 Place a single wire seal onto the wire and strip wire (single wire seals are not available with every version). Fig. 9 2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013) Fig. 10 3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing Fig. 11 4 Push seal into the housing Fig. 12 5 Assembly of the cover cap (not available with every version) and mounting in front panel Fig. 13 Required panel mount hole diameter: Diameter 12.5 mm. The panel thickness must not be under 1.0 mm. For environmental protection of the unmated connector, use of the covering cap is recommended. Cover: Part No. 1394739-1 All specifications subject to change. Consult Tyco Electronics for latest specifications. 27 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 28 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 4. Application Examples Fig. 14: Serial (Wire Diagram) Fig. 15: Parallel (Wire Diagram) 5. Storage See Product Specification 108-18701 6. Tooling The following tools are available for the contact crimping (please specify wire gauge required): Hand Tool, integral Locator and Die (Part No. 1-1105851-8), use `HVT' position on locator Hand Tool, only (Part No. 539973-1) An extraction tool (Part No. 1102855-3) is needed to disassemble the connector components. This tool is used to unlock the contact retention features, after which the contact can be removed and re-used if necessary. Technical Description Fig. 16 28 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 29 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Technical Data (Junction Box and One Pole Plug Connectors) Materials Socket and Pin Contacts: CuZn Housing: PPO, weatherproof against UV radiation and ozone Color Connector, Junction Box: Black Electrical Features Withstanding Voltage: 1000 V DC Current Rating: up to 25 A Contact Resistance: 5 m Contact Resistance (typical): 1 m Protection Class: II Mechanical Features Junction Boxes Dimensions: Depending on junction box type Temperature Range: -40 C to +105 C Wire Size Range: up to AWG 12 Protection Degree: IP 65, closed Connector Dimensions: Diameter 18 mm, (diameter 0.71 inch) Temperature Range: -40 C to +105 C Wire Size Range: AWG 14, AWG 12, AWG 10 stranded wire Protection Degree: IP 67, mated Contact Finish: silver plated, Mating Cycles: 50, silver plated Unmating Force: 30 - 40 Newton Additional Features: Coded housing ensures mating safety Contact voltage-proof Connector with crimp technology Standards IEC 61215 Edition 2, 61646, IEC 61730, Protection Class II, UL 1703 Subject to Change. All specifications subject to change. Consult Tyco Electronics for latest specifications. 29 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 30 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Numerical Index Part Number Page Part Number Page Part Number Page Part Number Page 539630-1 22 1394470-1 26 1740210-7 11 1987376-2 16, 17 539973-1 28 1394470-1 24 1740210-8 11 1987376-3 16, 17 956297-4 14 1394723-3 2 1740210-9 11 1987376-4 16, 17 956297-5 14 1394723-4 2 1-1740210-0 11 1987376-5 16, 17 956297-6 14 1394723-5 3 1740220-1 6 1-1987376-1 16, 17 1-956297-4 14 1394723-6 3 1740220-2 6 1-1987376-2 16, 17 1-956297-5 14 1394723-9 3 1740220-3 6 1-1987376-3 16, 17 1-956297-6 14 1-1394723-6 2 1740220-4 6 1-1987376-4 16, 17 956298-4 14 2-1394723-6 2 1740277-1 10 1-1987376-5 16, 17 956298-5 14 1394725-1 26 1740277-2 10 2-1987376-1 16, 17 956298-6 14 1394725-2 26 1740425-1 6 2-1987376-2 16, 17 1-956298-4 14 1394738-1 11 1740425-3 6 2-1987376-3 16, 17 1-956298-5 14 1394738-2 11 1740479-1 12 2-1987376-4 16, 17 1-956298-6 14 1394738-3 11, 20, 21 1740483-1 12 2-1987376-5 16, 17 956299-4 14 1394738-4 11, 20, 21 1740483-2 12 3-1987376-1 17 956299-5 14 1394739-1 11, 27 1740493-1 12 3-1987376-2 17 956299-6 14 1418677-2 24 1740493-2 12 3-1987376-3 17 1-956299-4 14 1418867-1 7 1740657-7 5 3-1987376-4 17 1-956299-5 14 1418867-2 7 1740657-8 5 3-1987376-5 17 1-956299-6 14 1418867-5 7 1740657-9 5 4-1987376-1 17 1102855-3 22, 23, 28 1418867-6 7 1-1740657-0 5 4-1987376-2 17 1-1105851-8 28 1-1418867-2 7 1740658-1 5 4-1987376-3 17 1394461-1 9 1-1418867-3 7 1740658-3 5 4-1987376-4 17 1394461-2 9 1534226-1 9 1740658-4 5 4-1987376-5 17 1394461-3 9, 16, 17 1534611-1 10 1740658-5 5 1394461-4 9, 16, 17, 1534611-2 10 1740699-1 4 20 1534858-1 23 1740699-6 4 6-1394461-1 9 1579000-4 22 1740700-1 4 6-1394461-2 9, 20 5-1579001-4 22 1740700-3 4 6-1394461-4 9 5-1579001-5 22 1740863-1 8 6-1394461-5 9 6-1579001-6 22 1740863-2 8 6-1394461-6 9 7-1579001-8 22 1740969-1 23 1394462-1 9 7-1579001-9 22 1740969-2 23 1394462-2 9 8-1579001-2 22 1740971-1 4 1394462-3 9, 16, 17, 4-1579002-2 22, 23 1740971-2 4 20, 21 1579004-8 22 1740972-1 4 1394462-4 9, 16, 17, 1-1579004-1 22 1740972-3 4 20, 21 1-1579004-2 22, 23 1954381-1 19 5-1394462-5 9 1579007-2 23 1986164-2 14 5-1394462-6 9 1579007-3 23 1986164-3 14 1394465-1 24 1579007-5 23 1986165-2 14 1394465-2 24 1740210-1 11 1986165-3 14 1394465-3 24 1740210-2 11 1986166-2 14 1394465-4 24 1740210-3 11 1986166-3 14 1394465-5 24 1740210-4 11 1987376-1 16, 17 30 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 31 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Restriction on the Use of Hazardous Substances (RoHS) Restriction on the Use of Hazardous Substances (RoHS) At Tyco Electronics, we're ready to support your RoHS requirements. We've assessed more than 1.5 million end items/components for RoHS compliance, and issued new part numbers where any change was required to eliminate the restricted materials. Part numbers in this catalog are identified as: RoHS Compliant Part numbers in this catalog are RoHS Compliant, unless marked otherwise. These products comply with European Union Directive 2002/95/EC as amended 1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE in certain electrical and electronic products sold into the EU as of 1 July 2006. Note: For purposes of this Catalog, included within the definition of RoHS Compliant are products that are clearly "Out of Scope" of the RoHS Directive such as hand tools and other non-electrical accessories. Non-RoHS Compliant These part numbers are identified with a "t" symbol. These products do not comply with the material restrictions of the European Union Directive 2002/95/EC. 5 of 6 Compliant A "l" symbol identifies these part numbers. These products do not fully comply with the European Union Directive 2002/95/EC because they contain lead in solderable interfaces (they do not contain any of the other five restricted substances above allowable limits). However, these products may be suitable for use in RoHS applications where there is an application-based exception for lead in solders, such as the server, storage, or networking infrastructure exemption. Note: Information regarding RoHS compliance is provided based on reasonable inquiry of our suppliers and represents our current actual knowledge based on the information provided by our suppliers. This information is subject to change. For latest compliance status, refer to our website referenced below. Getting the Information You Need Our comprehensive on-line RoHS Customer Support Center provides a forum to answer your questions and support your RoHS needs. A RoHS FAQ (Frequently Asked Questions) is available with links to more detailed information. You can also submit RoHS questions and receive a response within 24 hours during a normal work week. The Support Center also provides: Cross-Reference from Non-compliant to Compliant Products Ability to browse RoHS Compliant Products in our on-line catalog: http://ecommas.tycoelectronics.com/commerce/alt/RohsAltHome.do Downloadable Technical Data Customer Information Presentation More detailed information regarding the definitions used above RoHS Customer Support Center So whatever your questions when it comes to RoHS, we've got the answers at www.tycoelectronics.com/leadfree All specifications subject to change. Consult Tyco Electronics for latest specifications. 31 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 32 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Engineering Notes 32 All specifications subject to change. Consult Tyco Electronics for latest specifications. 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 3 Global Contacts Americas Argentina - Buenos Aires Phone: +54-11-4733-2200 Fax: +54-11-4733-2211 Brasil - Sao Paulo Phone: +55-11-3611-1311 Fax: +55-11-3611-0397 Canada - Toronto Phone: +1-905-475-6222 Fax: +1-905-474-5520 Product Information Center: Phone: +1-905-470-4425 Fax: +1-905-474-5525 Colombia - Bogota Phone: +57-1-231-9398 Fax: +57-1-660-0206 Mexico - Mexico City Phone: +52-55-1106-0800 +01-800-733-8926 Fax: +52-55-1106-0901 For Latin/South American Countries not shown Phone: +54-11-4733-2015 Fax: +54-11-4733-2083 United States Harrisburg, PA Phone: +1-717-564-0100 Fax: +1-717-986-7575 Product Information Center: Phone: +1-800-522-6752 Fax: +1-717-986-7575 Troy, MI Phone: +1-248-273-3359 Fax: +1-248-273-3322 Asia/Pacific Australia - Sydney Phone: +61-2-9554-2600 Fax: +61-2-9502-2556 Product Information Center: Phone: +61-2-9840-8200 Fax: +61-2-9634-6188 Japan - Kawasaki, Kanagawa Phone: +81-44-844-8111 Fax: +81-44-812-3207 Product Information Center: Phone: +81-44-844-8013 Fax: +81-44-812-3200 India - Bangalore Phone: +91-80-285-40800 Fax: +91-80-285-40820 Korea - Seoul Phone: +82-2-3415-4500 Fax: +82-2-3486-3810 Indonesia - Jakarta Phone: +65-6482-0311 Fax: +65-6482-1012 Malaysia - Selangor Phone: +60-3-7805-3055 Fax: +60-3-7805-3066 New Zealand - Auckland Phone: +64-9-634-4580 Fax: +64-9-634-4586 Singapore - Singapore Phone: +65-6482-0311 Fax: +65-6482-1012 Philippines - Makati City Phone: +632-848-0171 Fax: +632-867-8661 Taiwan - Taipei Phone: +886-2-8768-2788 Fax: +886-2-8768-2268 People's Republic of China Hong Kong Phone: +852-2735-1628 Fax: +852-2735-0243 Thailand - Bangkok Phone: +66-2-955-0500 Fax: +66-2-955-0505 Shanghai Phone: +86-21-2407-1588 Fax: +86-21-2407-1599 Vietnam - Ho Chi Minh City Phone: +84-8-930-5546 Fax: +84-8-930-3443 Europe/Middle East /Africa Austria - Vienna Phone: +43-1-905-60-0 Fax: +43-1-905-60-1333 Product Information Center: Phone: +43-1-905-60-1249 Fax: +43-1-905-60-1251 France - Cergy-Pontoise Cedex Phone: +33-1-3420-8888 Fax: +33-1-3420-8600 Product Information Center: Phone: +33-1-3420-8686 Fax: +33-1-3420-8623 Belarus - Minsk Phone: +375-17-237-47-94 Fax: +375-17-237-47-94 France Export Divisions - Cergy-Pontoise Cedex Phone: +33-1-3420-8804 Fax: +33-1-3420-8699 Belgium - Kessel-Lo Phone: +32-16-352-300 Fax: +32-16-352-352 Bulgaria - Sofia Phone: +359-2-971-2152 Fax: +359-2-971-2153 Czech Republic and Slovakia Czech Republic - Kurim Phone: +420-541-162-111 Fax: +420-541-162-223 Product Information Center: Phone: +420-541-162-113 Fax: +420-541-162-132 Denmark - Glostrup Phone: +45-43-48-04-00 Fax: +45-43-44-14-14 Egypt - Cairo Phone: +202-419-2334 Fax: +202-417-7647 Estonia - Tartu Phone: +372-5138-274 Fax: +372-7400-779 Finland - Helsinki Phone: +358-95-12-34-20 Fax: +358-95-12-34-250 Germany - Bensheim Phone: +49-6251-133-0 Fax: +49-6251-133-1600 Product Information Center: Phone: +49-6251-133-1999 Fax: +49-6251-133-1988 Greece - Athens Phone: +30-210-9370-396/397 Fax: +30-210-9370-655 Hungary - Budapest Phone: +36-1-289-1000 Fax: +36-1-289-1010 Product Information Center: Phone: +36-1-289-1016 Fax: +36-1-289-1017 Ireland - Dublin Phone: +353-1-866-5612 Fax: +353-1-866-5714 Israel - Petach-Tikva Phone: +972-3-929-0999 Fax: +972-3-919-1088 Italy - Collegno (Torino) Phone: +39-011-4012-111 Fax: +39-011-4031-116 Product Information Center: Phone: +39-011-4012-428 Fax: +39-011-40-287-428 Lithuania and Latvia Lithuania - Vilnius Phone: +370-5-213-1402 Fax: +370-5-213-1403 Product Information Center: Phone: +370-5-211-3016 Fax: +370-5-213-1403 South Africa - Port Elizabeth Phone: +27-41-503-4500 Fax: +27-41-581-0440 Netherlands - 's-Hertogenbosch Phone: +31-73-6246-246 Fax: +31-73-6212-365 Product Information Center: Phone: +31-73-6246-999 Fax: +31-73-6246-998 Sweden - Upplands Vasby Phone: +46-8-50-72-50-00 Fax: +46-8-50-72-50-01 Norway - Nesbru Phone: +47-66-77-88-50 Fax: +47-66-77-88-55 Turkey - Istanbul Phone: +90-212-281-8181-83 +90-212-282-5130/5430 Fax: +90-212-281-8184 Poland - Warsaw Phone: +48-22-4576-700 Fax: +48-22-4576-720 Product Information Center: Phone: +48-22-4576-704 Fax: +48-22-4576-720 Romania - Bucharest Phone: +40-21-311-3479/3596 Fax: +40-21-312-0574 Russia - Moscow Phone: +7-495-790-7902 Fax: +7-495-721-1893 Product Information Center: Phone: +7-495-790-7902-404 Fax: +7-495-790-7902-401 Spain - Barcelona Phone: +34-93-291-0330 Fax: +34-93-201-7879 Switzerland - Steinach Phone: +41-71-447-0447 Fax: +41-71-447-0444 Ukraine - Kiev Phone: +380-44-206-2265 Fax: +380-44-206-2264 Product Information Center: Phone: +380-44-206-2265 Fax: +380-44-206-2264 United Kingdom - Stanmore, Middlesex Phone: +44-8706-080208 Fax: +44-208-954-6234 Product Information Center: Freephone (UK only): +0800-267-666 Phone: +44-8706-080208 Fax: +44-208-420-8095 Russia - St. Petersburg Phone: +7-812-718-8192 Fax: +7-812-718-8193 Slovenia - Ljubljana Phone: +386-1561-3270 Fax: +386-1561-3240 www.tycoelectronics.com 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Tyco Electronics AMP GmbH Siemensstr. 13 67346 Speyer / Germany Phone: +49-(0)6232-30-2520 Fax: +49-(0)6232-30-2243 www.tycoelectronics.com AMP, SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. (c) 2008 Tyco Electronics Ltd. 889753-3 Revised 6-2008 5M ST Seite 4