Features
+5 V CMOS compatibility
8 ns maximum pulse width
distortion
20 ns maximum prop. delay skew
High speed: 12 Mbd
40 ns maximum prop. delay
10 kV/µs minimum common mode
rejection
-40°C to 100°C temperature range
Safety and regulatory approvals
UL Recognized
3750 V rms for 1 min. per
UL 1577
CSA Component Acceptance
Notice #5
IEC/EN/DIN EN 60747-5-2
–V
IORM = 630 Vpeak for
HCPL-7710 Option 060
–V
IORM = 560 Vpeak for
HCPL-0710 Option 060
Applications
Digital fieldbus isolation:
DeviceNet, SDS, Profibus
AC plasma display panel level
shifting
Multiplexed data transmission
Computer peripheral interface
Microprocessor system interface
Description
Available in either an 8-pin DIP or
SO-8 package style respectively,
the HCPL-7710 or HCPL-0710
optocouplers utilize the latest
CMOS IC technology to achieve
outstanding performance with
very low power consumption. The
HCPL-x710 require only two
bypass capacitors for complete
CMOS compatibility.
Functional Diagram
Basic building blocks of the
HCPL-x710 are a CMOS LED
driver IC, a high speed LED and a
CMOS detector IC. A CMOS logic
input signal controls the LED
driver IC which supplies current
to the LED. The detector IC
incorporates an integrated
photodiode, a high-speed
transimpedance amplifier, and a
voltage comparator with an
output driver.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this
component to prevent damage and/or degradation which may be induced by ESD.
* Pin 3 is the anode of the internal LED and must be left unconnected for guaranteed data sheet
performance. Pin 7 is not connected internally.
** A 0.1
µ
F bypass capacitor must be connected between pins 1 and 4, and 5 and 8.
8
7
6
1
3
SHIELD 5
2
4
**V
DD1
V
I
*
GND
1
V
DD2
**
V
O
GND
2
V
I
, INPUT LED1
H
LOFF
ON
TRUTH TABLE
(POSITIVE LOGIC)
NC*
I
O
LED1
V
O
, OUTPUT
H
L
Agilent HCPL-7710, HCPL-0710
40 ns Propagation Delay,
CMOS Optocoupler
Data Sheet
2
Package Outline Drawing
HCPL-7710 8-Pin DIP Package
9.65 ± 0.25
(0.380 ± 0.010)
1.78 (0.070) MAX.
1.19 (0.047) MAX.
A XXXXV
YYWW
DATE CODE
1.080 ± 0.320
(0.043 ± 0.013) 2.54 ± 0.25
(0.100 ± 0.010)
0.51 (0.020) MIN.
0.65 (0.025) MAX.
4.70 (0.185) MAX.
2.92 (0.115) MIN.
DIMENSIONS IN MILLIMETERS AND (INCHES).
5678
4321
5° TYP. 0.254 + 0.076
- 0.051
(0.010+ 0.003)
- 0.002)
7.62 ± 0.25
(0.300 ± 0.010)
6.35 ± 0.25
(0.250 ± 0.010)
TYPE NUMBER
*OPTION 300 AND 500 NOT MARKED.
NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX.
OPTION 060 CODE*
3.56 ± 0.13
(0.140 ± 0.005)
Selection Guide
8-Pin DIP Small Outline
(300 Mil) SO-8
HCPL-7710 HCPL-0710
Ordering Information
Specify Part Number followed by Option Number (if desired)
Example
HCPL-7710#XXXX
060 = IEC/EN/DIN EN 60747-5-2 Option.
300 = Gull Wing Surface Mount Option (HCPL-7710 only).
500 = Tape and Reel Packaging Option.
XXXE = Lead Free Option
No Option and Option 300 contain 50 units (HCPL-7710), 100 units (HCPL-0710) per tube.
Option 500 contain 1000 units (HCPL-7710), 1500 units (HCPL-0710) per reel.
Option data sheets available. Contact Agilent sales representative or authorized distributor.
Remarks: The notation “#” is used for existing products, while (new) products launched since 15th July 2001 and lead free option will use “–”
3
Package Outline Drawing
HCPL-7710 Package with Gull Wing Surface Mount Option 300
Package Outline Drawing
HCPL-0710 Outline Drawing (Small Outline SO-8 Package)
0.635 ± 0.25
(0.025 ± 0.010) 12° NOM.
9.65 ± 0.25
(0.380 ± 0.010)
0.635 ± 0.130
(0.025 ± 0.005)
7.62 ± 0.25
(0.300 ± 0.010)
5
6
7
8
4
3
2
1
9.65 ± 0.25
(0.380 ± 0.010)
6.350 ± 0.25
(0.250 ± 0.010)
1.016 (0.040)
1.27 (0.050)
10.9 (0.430)
2.0 (0.080)
LAND PATTERN RECOMMENDATION
1.080 ± 0.320
(0.043 ± 0.013)
3.56 ± 0.13
(0.140 ± 0.005)
1.780
(0.070)
MAX.
1.19
(0.047)
MAX.
2.54
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX.
0.254 + 0.076
- 0.051
(0.010+ 0.003)
- 0.002)
XXXV
YWW
8765
4321
5.994 ± 0.203
(0.236 ± 0.008)
3.937 ± 0.127
(0.155 ± 0.005)
0.406 ± 0.076
(0.016 ± 0.003) 1.270
(0.050)BSC
5.080 ± 0.127
(0.200 ± 0.005)
3.175 ± 0.127
(0.125 ± 0.005) 1.524
(0.060)
45° X 0.432
(0.017)
0.228 ± 0.025
(0.009 ± 0.001)
TYPE NUMBER
(LAST 3 DIGITS)
DATE CODE
0.305
(0.012)MIN.
TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH)
5.207 ± 0.254 (0.205 ± 0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES) MAX.
OPTION NUMBER 500 NOT MARKED.
NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX.
0.203 ± 0.102
(0.008 ± 0.004)
7°
PIN ONE
0 ~ 7°
*
*
7.49 (0.295)
1.9 (0.075)
0.64 (0.025)
LAND PATTERN RECOMMENDATION
4
All Agilent data sheets report the
creepage and clearance inherent
to the optocoupler component
itself. These dimensions are
needed as a starting point for the
equipment designer when
determining the circuit insulation
requirements. However, once
mounted on a printed circuit
board, minimum creepage and
clearance requirements must be
met as specified for individual
equipment standards. For
creepage, the shortest distance
path along the surface of a
printed circuit board between the
solder fillets of the input and
output leads must be considered.
There are recommended
techniques such as grooves and
ribs which may be used on a
printed circuit board to achieve
desired creepage and clearances.
Creepage and clearance distances
will also change depending on
factors such as pollution degree
and insulation level.
Regulatory Information
The HCPL-x710 have been
approved by the following
organizations:
UL
Recognized under UL 1577,
component recognition program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01.
(Option 060 only)
Recommended Pb-Free IR Profile
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160°C
140°C
150°C
PEAK
TEMP.
245°C
PEAK
TEMP.
240°CPEAK
TEMP.
230°C
SOLDERING
TIME
200°C
PREHEATING TIME
150°C, 90 + 30 SEC.
2.5°C ± 0.5°C/SEC.
3°C + 1°C/0.5°C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3°C + 1°C/0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
Solder Reflow Thermal Profile
Insulation and Safety Related Specifications Value
Parameter Symbol 7710 0710 Units Conditions
Minimum External Air L(I01) 7.1 4.9 mm Measured from input terminals to output
Gap (Clearance) terminals, shortest distance through air.
Minimum External L(I02) 7.4 4.8 mm Measured from input terminals to output
Tracking (Creepage) terminals, shortest distance path along
body.
Minimum Internal Plastic 0.08 0.08 mm Insulation thickness between emitter and
Gap (Internal Clearance) detector; also known as distance through
insulation.
Tracking Resistance CTI 175 175 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking
Index)
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89,
Table 1)
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5 °C of ACTU AL
PEAK TEMPERA TURE
tp
ts
PREHEAT
60 to 180 SEC.
tL
TL
Tsmax
Tsmin
25
Tp
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
Tsmax = 200 °C, Tsmin = 150 °C
5
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060) HCPL-7710 HCPL-0710
Description Symbol Option 060 Option 060 Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 V rms I-IV I-IV
for rated mains voltage 300 V rms I-IV I-III
for rated mains voltage 450 V rms I-III
Climatic Classification 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage VIORM 630 560 V peak
Input to Output Test Voltage, Method b† VPR 1181 1050 V peak
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a† VPR 945 840 V peak
VIORM x 1.5 = VPR, Type and Sample Test,
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage† VIOTM 6000 4000 V peak
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature TS175 150 °C
Input Current IS,INPUT 230 150 mA
Output Power PS,OUTPUT 600 600 mW
Insulation Resistance at TS, V10 = 500 V RIO 109109
†Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
IEC/EN/DIN EN 60747-5-2, for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Figure
Storage Temperature TS–55 125 °C
Ambient Operating Temperature TA–40 +100 °C
Supply Voltages VDD1, VDD2 0 6.0 Volts
Input Voltage VI–0.5 VDD1 +0.5 Volts
Output Voltage VO–0.5 VDD2 +0.5 Volts
Input Current II–10 +10 mA
Average Output Current IO10 mA
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reflow Temperature Profile See Solder Reflow Temperature Profile Section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Figure
Ambient Operating Temperature TA–40 +100 °C
Supply Voltages VDD1, VDD2 4.5 5.5 V
Logic High Input Voltage VIH 2.0 VDD1 V 1, 2
Logic Low Input Voltage VIL 0.0 0.8 V
Input Signal Rise and Fall Times tr, tf1.0 ms
6
Electrical Specifications
Test conditions that are not specified can be anywhere within the recommended operating range. All typical specifications
are at TA = +25°C, VDD1 = VDD2 = +5 V.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
DC Specifications
Logic Low Input IDD1L 6.0 10.0 mA VI = 0 V 1
Supply Current
Logic High Input IDD1H 1.5 3.0 mA VI = V DDI
Supply Current
Input Supply Current IDD1 13.0 mA
Output Supply Current IDD2 5.5 11.0 mA
Input Current II-10 10 µA
Logic High Output VOH 4.4 5.0 V IO = -20 µA, V I = VIH 1, 2
Voltage 4.0 4.8 IO = -4 mA, VI = VIH
Logic Low Output VOL 0 0.1 V IO = 20 µA, VI = VIL
Voltage 0.5 1.0 IO = 4 mA, VI = VIL
Switching Specifications
Propagation Delay Time tPHL 20 40 ns CL = 15 pF 3, 7 2
to Logic Low Output CMOS Signal Levels
Propagation Delay Time tPLH 23 40
to Logic High Output
Pulse Width PW 80 3
Data Rate 12.5 MBd
Pulse Width Distortion PWD 3 8 ns 4, 8 4
|tPHL - tPLH|
Propagation Delay Skew tPSK 20 5
Output Rise Time tR9 5, 9
(10 - 90%)
Output Fall Time tF86,
(90 - 10%) 10
Common Mode |CMH| 10 20 kV/µsV
I = VDD1, VO >6
Transient Immunity at 0.8 VDD1,
Logic High Output VCM = 1000 V
Common Mode |CML|10 20 V
I = 0 V, VO > 0.8 V,
Transient Immunity at VCM = 1000 V
Logic Low Output
Input Dynamic Power CPD1 60 pF 7
Dissipation
Capacitance
Output Dynamic Power CPD2 10
Dissipation
Capacitance
7
Notes:
1. The LED is ON when VI is low and OFF
when VI is high.
2. tPHL propagation delay is measured from
the 50% level on the falling edge of the VI
signal to the 50% level of the falling edge
of the VO signal. tPLH propagation delay is
measured from the 50% level on the rising
edge of the VI signal to the 50% level of the
rising edge of the VO signal.
3. Mimimum Pulse Width is the shortest
pulse width at which 10% maximum, Pulse
Width Distortion can be guaranteed.
Maximum Data Rate is the inverse of
Minimum Pulse Width. Operating the
HCPL-x710 at data rates above 12.5 MBd is
possible provided PWD and data
dependent jitter increases and relaxed
noise margins are tolerable within the
application. For instance, if the maximum
allowable variation of bit width is 30%, the
maximum data rate becomes 37.5 MBd.
Please note that HCPL-x710 performances
above 12.5 MBd are not guaranteed by
Hewlett-Packard.
4. PWD is defined as |tPHL - tPLH|.
%PWD (percent pulse width distortion) is
equal to the PWD divided by pulse width.
5. tPSK is equal to the magnitude of the worst
case difference in tPHL and/or tPLH that will
be seen between units at any given
temperature within the recommended
operating conditions.
6. CMH is the maximum common mode
voltage slew rate that can be sustained
while maintaining VO > 0.8 VDD2. CML is the
maximum common mode voltage slew rate
that can be sustained while maintaining VO
< 0.8 V. The common mode voltage slew
rates apply to both rising and falling
common mode voltage edges.
7. Unloaded dynamic power dissipation is
calculated as follows: CPD * VDD2 * f + IDD *
VDD, where f is switching frequency in
MHz.
8. Device considered a two-terminal device:
pins 1, 2, 3, and 4 shorted together and
pins 5, 6, 7, and 8 shorted together.
9. In accordance with UL1577, each HCPL-
0710 is proof tested by applying an
insulation test voltage 4500 VRMS for 1
second (leakage detection current limit, II-O
5 µA). Each HCPL-7710 is proof tested by
applying an insulation test voltage 4500 V
rms for 1 second (leakage detection current
limit, II-O 5 µA).
10. The Input-Output Momentary Withstand
Voltage is a dielectric voltage rating that
should not be interpreted as an input-output
continuous voltage rating. For the
continuous voltage rating refer to your
equipment level safety specification or
Agilent Application Note 1074 entitled
“Optocoupler Input-Output Endurance
Voltage.”
11. CI is the capacitance measured at pin 2 (VI).
V
O
(V)
0
0
V
I
(V)
5
4
1
4123
5
3
2
0 °C
25 °C
85 °C
VITH (V)
4.5
1.6
VDD1 (V)
5.5
2.1
1.7
5.254.75 5
2.2
2.0
1.8
1.9
0 °C
25 °C
85 °C
TPLH, TPHL (ns)
0
15
TA (C)
80
27
17
6020 30
29
25
19
21
10 40 50 70
23 TPLH
TPHL
Package Characteristics
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Input-Output Momentary 0710 VISO 3750 Vrms RH 50%, 8, 9,
Withstand Voltage 7710 3750 t = 1 min., 10
TA = 25°C
Resistance RI-O 1012 VI-O = 500 Vdc 8
(Input-Output)
Capacitance CI-O 0.6 pF f = 1 MHz
(Input-Output)
Input Capacitance CI3.0 11
Input IC Junction-to-Case -7710 θjci 145 °C/W Thermocouple
Thermal Resistance -0710 160 located at center
Output IC Junction-to-Case -7710 θjco 140 underside of package
Thermal Resistance -0710 135
Package Power Dissipation PPD 150 mW
Figure 1. Typical output voltage vs. input
voltage. Figure 2. Typical input voltage switching
threshold vs. input supply voltage. Figure 3. Typical propagation delays vs.
temperature.
8
Figure 11. Thermal derating curve, dependence of Safety Limiting Value with case temperature
per IEC/EN/DIN EN 60747-5-2 .
PWD
(ns)
0
0
T
A
(C)
80
3
6020
4
1
40
2
T
R
(ns)
0
8
T
A
(C)
80
10
6020
11
9
40
T
F
(ns)
0
2
T
A
(C)
80
6
6020
7
3
40
5
4
TR (ns)
0
1
CI (pF)
35
19
25
21
5
15
11
1052030
7
15
17
13
9
3
FALL TIME (ns)
0
0
CI (pF)
35
9
25
10
2
15
5
1052030
3
7
8
6
4
1
OUTPUT POWER P
S
, INPUT CURRENT I
S
0
0
T
A
CASE TEMPERATURE °C
20050
400
12525 75 100 150
600
800
200
100
300
500
700
175
(230)
P
S
(mW)
I
S
(mA)
STANDARD 8 PIN DIP PRODUCT
OUTPUT POWER P
S
, INPUT CURRENT I
S
0
0
T
A
CASE TEMPERATURE °C
20050
400
12525 75 100 150
600
800
200
100
300
500
700
175
(150)
P
S
(mW)
I
S
(mA)
SURFACE MOUNT SO8 PRODUCT
T
PLH
, T
PHL
(ns)
15
15
C
I
(pF)
50
27
40
29
17
30
23
21
2520 35 45
19
25
T
PLH
T
PHL
PWD
(ns)
15
0
C
I
(pF)
50
5
40
6
1
30
3
2520 35 45
2
4
Figure 4. Typical pulse width distortion vs.
temperature. Figure 5. Typical rise time vs. temperature. Figure 6. Typical fall time vs. temperature.
Figure 7. Typical propagation delays vs.
output load capacitance. Figure 8. Typical pulse width distortion vs.
output load capacitance. Figure 9. Typical rise time vs. load
capacitance.
Figure 10. Typical fall time vs. load
capacitance.
9
Application Information
Bypassing and PC Board Layout
The HCPL-x710 optocouplers are
extremely easy to use. No external
interface circuitry is required
because the HCPL-x710 use high-
speed CMOS IC technology
allowing CMOS logic to be
connected directly to the inputs
and outputs.
As shown in Figure 12, the only
external components required for
proper operation are two bypass
capacitors. Capacitor values
should be between 0.01 µF and
0.1 µF. For each capacitor, the
total lead length between both
ends of the capacitor and the
power-supply pins should not
exceed 20 mm. Figure 13
illustrates the recommended
printed circuit board layout for
the HPCL-x710.
Figure 12. Recommended Printed Circuit Board layout.
Figure 13. Recommended Printed Circuit Board layout.
V
DD2
C1 C2
710
YWW
V
O
GND2
V
DD1
V
I
GND1
C1, C2 = 0.01 µF TO 0.1 µF
7
5
6
8
2
3
4
1
GND
2
C1 C2
NC
V
DD2
NC V
O
V
DD1
V
I
710
YWW
C1, C2 = 0.01 µF TO 0.1 µF
GND
1
Propagation Delay, Pulse-Width
Distortion and Propagation Delay
Skew
Propagation Delay is a figure of
merit which describes how
quickly a logic signal propagates
through a system. The propaga-
tion delay from low to high (tPLH)
is the amount of time required for
an input signal to propagate to the
output, causing the output to
change from low to high.
Similarly, the propagation delay
from high to low (tPHL) is the
amount of time required for the
input signal to propagate to the
output, causing the output to
change from high to low. See
Figure 14.
Figure 14.
INPUT
t
PLH
t
PHL
OUTPUT
V
I
V
O
10% 90%90% 10%
V
OH
V
OL
0 V
50% 5 V CMOS
2.5 V CMOS
10
Figure 15. Propagation delay skew waveform. Figure 16. Parallel data transmission example.
Propagation delay skew repre-
sents the uncertainty of where an
edge might be after being sent
through an optocoupler. Figure 16
shows that there will be
uncertainty in both the data and
clock lines. It is important that
these two areas of uncertainty not
overlap, otherwise the clock
signal might arrive before all of
the data outputs have settled, or
some of the data outputs may
start to change before the clock
signal has arrived. From these
considerations, the absolute
minimum pulse width that can be
sent through optocouplers in a
parallel application is twice tPSK.
A cautious design should use a
slightly longer pulse width to
ensure that any additional
uncertainty in the rest of the
circuit does not cause a problem.
The HCPL-x710 optocouplers
offer the advantage of guaranteed
specifications for propagation
delays, pulse-width distortion,
and propagation delay skew over
the recommended temperature
and power supply ranges.
Pulse-width distortion (PWD) is
the difference between tPHL and
tPLH and often determines the
maximum data rate capability of a
transmission system. PWD can be
expressed in percent by dividing
the PWD (in ns) by the minimum
pulse width (in ns) being trans-
mitted. Typically, PWD on the
order of 20 - 30% of the minimum
pulse width is tolerable. The PWD
specification for the HCPL-x710 is
8 ns (10%) maximum across
recommended operating condi-
tions. 10% maximum is dictated
by the most stringent of the three
fieldbus standards, PROFIBUS.
Propagation delay skew, tPSK, is
an important parameter to con-
sider in parallel data applications
where synchronization of signals
on parallel data lines is a concern.
If the parallel data is being sent
through a group of optocouplers,
differences in propagation delays
will cause the data to arrive at the
outputs of the optocouplers at
different times. If this difference
in propagation delay is large
enough it will determine the
maximum rate at which parallel
data can be sent through the
optocouplers.
Propagation delay skew is defined
as the difference between the
minimum and maximum propa-
gation delays, either tPLH or tPHL,
for any given group of optocoup-
lers which are operating under
the same conditions (i.e., the same
drive current, supply voltage,
output load, and operating
temperature). As illustrated in
Figure 15, if the inputs of a group
of optocouplers are switched
either ON or OFF at the same
time, tPSK is the difference
between the shortest propagation
delay, either tPLH or tPHL, and the
longest propagation delay, either
tPLH or tPHL.
As mentioned earlier, tPSK can
determine the maximum parallel
data transmission rate. Figure 16
is the timing diagram of a typical
parallel data application with
both the clock and data lines
being sent through the
optocouplers. The figure shows
data and clock signals at the
inputs and outputs of the
optocouplers. In this case the data
is assumed to be clocked off of the
rising edge of the clock.
50%
50%
tPSK
VI
VO
VI
VO
2.5 V,
CMOS
2.5 V,
CMOS
DATA
INPUTS
CLOCK
DATA
OUTPUTS
CLOCK
tPSK
tPSK
11
Optical Isolation for Field Bus
Networks
To recognize the full benefits of
these networks, each recommends
providing galvanic isolation using
Agilent optocouplers. Since
network communication is bi-
directional (involving receiving
data from and transmitting data
onto the network), two Agilent
optocouplers are needed. By
providing galvanic isolation, data
integrity is retained via noise
reduction and the elimination of
false signals. In addition, the
Figure 17. Typical field bus communication physical model.
network receives maximum
protection from power system
faults and ground loops.
Within an isolated node, such as
the DeviceNet Node shown in
Figure 18, some of the node’s
components are referenced to a
ground other than V- of the
network. These components could
include such things as devices
with serial ports, parallel ports,
RS232 and RS485 type ports. As
shown in Figure 18, power from
the network is used only for the
transceiver and input (network)
side of the optocouplers.
Isolation of nodes connected to
any of the three types of digital
field bus networks is best
achieved by using the HCPL-x710
optocouplers. For each network,
the HCPL-x710 satisify the critical
propagation delay and pulse
width distortion requirements
over the temperature range of 0°C
to +85°C, and power supply
voltage range of 4.5 V to 5.5 V.
Digital Field Bus Communication
Networks
To date, despite its many draw-
backs, the 4 - 20 mA analog
current loop has been the most
widely accepted standard for
implementing process control
systems. In today’s manufacturing
environment, however, automated
systems are expected to help
manage the process, not merely
monitor it. With the advent of
digital field bus communication
networks such as DeviceNet,
PROFIBUS, and Smart
Distributed Systems (SDS), gone
are the days of constrained
information. Controllers can now
receive multiple readings from
field devices (sensors, actuators,
etc.) in addition to diagnostic
information.
The physical model for each of
these digital field bus communica-
tion networks is very similar as
shown in Figure 17. Each includes
one or more buses, an interface
unit, optical isolation, transceiver,
and sensing and/or actuating
devices.
CONTROLLER
TRANSCEIVER
OPTICAL
ISOLATION
BUS
INTERFACE
TRANSCEIVER
OPTICAL
ISOLATION
BUS
INTERFACE
TRANSCEIVER
OPTICAL
ISOLATION
BUS
INTERFACE
TRANSCEIVER
OPTICAL
ISOLATION
BUS
INTERFACE
TRANSCEIVER
OPTICAL
ISOLATION
BUS
INTERFACE
FIELD BUS
XXXXXX
YYY
SENSOR
DEVICE
CONFIGURATION
MOTOR
STARTER
MOTOR
CONTROLLER
12
Implementing DeviceNet and SDS
with the HCPL-x710
With transmission rates up to 1
Mbit/s, both DeviceNet and SDS
are based upon the same
broadcast-oriented, communica-
tions protocol — the Controller
Area Network (CAN). Three types
of isolated nodes are
recommended for use on these
networks: Isolated Node Powered
by the Network (Figure 19),
Figure 18. Typical DeviceNet node.
Isolated Node with Transceiver
Powered by the Network (Figure
20), and Isolated Node Providing
Power to the Network (Figure 21).
Isolated Node Powered by the
Network
This type of node is very flexible
and as can be seen in Figure 19, is
regarded as “isolated” because not
all of its components have the
same ground reference. Yet, all
Figure 19. Isolated node powered by the network.
components are still powered by
the network. This node contains
two regulators: one is isolated and
powers the CAN controller, node-
specific application and isolated
(node) side of the two optocoup-
lers while the other is non-
isolated. The non-isolated
regulator supplies the transceiver
and the non-isolated (network)
half of the two optocouplers.
NODE/APP SPECIFIC
uP/CAN
HCPL
x710 HCPL
x710
TRANSCEIVER
LOCAL
NODE
SUPPLY
5 V REG.
NETWORK
POWER
SUPPLY
V+ (SIGNAL)
V (SIGNAL)
V+ (POWER)
V (POWER)
GALVANIC
ISOLATION
BOUNDARY
AC LINE
DRAIN/SHIELD
SIGNAL
POWER
NODE/APP SPECIFIC
uP/CAN
HCPL
x710 HCPL
x710
TRANSCEIVER REG.
V+ (SIGNAL)
V (SIGNAL)
V+ (POWER)
V (POWER)
GALVANIC
ISOLATION
BOUNDARY
DRAIN/SHIELD
SIGNAL
POWER
ISOLATED
SWITCHING
POWER
SUPPLY
NETWORK
POWER
SUPPLY
13
Figure 20. Isolated node with transceiver powered by the network.
Isolated Node with Transceiver
Powered by the Network
Figure 20 shows a node powered
by both the network and another
source. In this case, the trans-
ceiver and isolated (network) side
of the two optocouplers are
powered by the network. The rest
of the node is powered by the AC
line which is very beneficial when
an application requires a
significant amount of power. This
method is also desirable as it does
not heavily load the network.
More importantly, the unique
“dual-inverting” design of the
HCPL-x710 ensure the network
will not “lock-up” if either AC line
power to the node is lost or the
node powered-off. Specifically,
when input power (VDD1) to the
HCPL-x710 located in the
transmit path is eliminated, a
RECESSIVE bus state is ensured
as the HCPL-x710 output voltage
(V
O) go HIGH.
*Bus V+ Sensing
It is suggested that the Bus V+
sense block shown in Figure 20 be
implemented. A locally powered
node with an un-powered isolated
Physical Layer will accumulate
errors and become bus-off if it
attempts to transmit. The Bus V+
sense signal would be used to
change the BOI attribute of the
DeviceNet Object to the “auto-
reset” (01) value. Refer to Volume
1, Section 5.5.3. This would cause
the node to continually reset until
bus power was detected. Once
power was detected, the BOI
attribute would be returned to the
“hold in bus-off” (00) value. The
BOI attribute should not be left in
the “auto-reset” (01) value since
this defeats the jabber protection
capability of the CAN error
confinement. Any inexpensive
low frequency optical isolator can
be used to implement this feature.
NODE/APP SPECIFIC
uP/CAN
HCPL
x710 HCPL
x710
TRANSCEIVER
NON ISO
5 V
REG.
NETWORK
POWER
SUPPLY
V+ (SIGNAL)
V (SIGNAL)
V+ (POWER)
V (POWER)
GALVANIC
ISOLATION
BOUNDARY
AC LINE
DRAIN/SHIELD
SIGNAL
POWER
*HCPL
x710
* OPTIONAL FOR BUS V + SENSE
14
Figure 21. Isolated node providing power to the network.
Isolated Node Providing Power to
the Network
Figure 21 shows a node providing
power to the network. The AC line
powers a regulator which
provides five (5) volts locally. The
AC line also powers a 24 volt
isolated supply, which powers the
network, and another five-volt
regulator, which, in turn, powers
the transceiver and isolated
(network) side of the two
optocouplers. This method is
recommended when there are a
limited number of devices on the
network that don’t require much
power, thus eliminating the need
for separate power supplies.
More importantly, the unique
“dual-inverting” design of the
HCPL-x710 ensure the network
will not “lock-up” if either AC line
power to the node is lost or the
node powered-off. Specifically,
when input power (VDD1) to the
HCPL-x710 located in the
transmit path is eliminated, a
RECESSIVE bus state is ensured
as the HCPL-x710 output voltage
(VO) go HIGH.
NODE/APP SPECIFIC
uP/CAN
HCPL
x710 HCPL
x710
TRANSCEIVER 5 V REG.
V+ (SIGNAL)
V (SIGNAL)
V+ (POWER)
V (POWER)
GALVANIC
ISOLATION
BOUNDARY
AC LINE
DRAIN/SHIELD
SIGNAL
POWER
ISOLATED
SWITCHING
POWER
SUPPLY
5 V REG.
DEVICENET NODE
15
Power Supplies and Bypassing
The recommended DeviceNet
application circuit is shown in
Figure 22. Since the HCPL-x710
are fully compatible with CMOS
logic level signals, the optocoupler
is connected directly to the CAN
Figure 22. Recommended DeviceNet application circuit.
Implementing PROFIBUS with the
HCPL-x710
An acronym for Process Fieldbus,
PROFIBUS is essentially a
twisted-pair serial link very
similar to RS-485 capable of
achieving high-speed communi-
cation up to 12 MBd. As shown in
Figure 23, a PROFIBUS Controller
(PBC) establishes the connection
of a field automation unit (control
or central processing station) or a
field device to the transmission
medium. The PBC consists of the
line transceiver, optical isolation,
frame character transmitter/
receiver (UART), and the FDL/
APP processor with the interface
to the PROFIBUS user.
transceiver. Two bypass
capacitors (with values between
0.01 and 0.1 µF) are required and
should be located as close as
possible to the input and output
power-supply pins of the HCPL-
x710. For each capacitor, the total
Figure 23. PROFIBUS Controller (PBC).
PROFIBUS USER:
CONTROL STATION
(CENTRAL PROCESSING)
OR FIELD DEVICE
USER INTERFACE
FDL/APP
PROCESSOR
TRANSCEIVER
OPTICAL ISOLATION
UART
PBC
MEDIUM
lead length between both ends of
the capacitor and the power
supply pins should not exceed 20
mm. The bypass capacitors are
required because of the high-
speed digital nature of the signals
inside the optocoupler.
8
7
6
1
3
5
2
4
VDD1
VIN
GND1
VDD2
VO
GND2
HCPL-x710
4
3
2
5
7
1
6
8
GND2
VO
VDD2
GND1
VIN
VDD1
HCPL-x710
GND
ISO 5 V
ISO 5 V
0.01 µF
RX0
0.01 µF
TX0 0.01
µF
0.01
µF
TxD CANH
REF
RXD
82C250
VCC
GND
Rs
CANL
C4
0.01 µF
+
VREF
LINEAR OR
SWITCHING
REGULATOR
5 V
5 V
++
R1
1 M
C1
0.01 µF
500 V
D1
30 V
5 V+
4 CAN+
3 SHIELD
2 CAN
1 V
GALVANIC
ISOLATION
BOUNDARY
Figure 24. Recommended PROFIBUS application circuit.
1
2
3
8
6
4
7
5
V
DD2
V
O
GND
2
V
DD1
V
IN
GND
1
HCPL-x710
8
7
6
1
3
5
2
4
V
DD1
V
IN
GND
1
V
DD2
V
O
GND
2
HCPL-x710
5 V
0.01 µF
0.01 µF
0.01
µF
0.01
µF
RA
SN75176B
V
CC
GND
DE
B
0.01
µF
ISO 5 V
1 M
0.01 µF
+
GALVANIC
ISOLATION
BOUNDARY
5 V ISO 5 V
RE
D
1
4
3
2
Rx
ISO 5 V
Tx
8
7
6
1
3
5
2
4
ANODE
V
CC
V
O
GND
5 V
0.01
µF
ISO 5 V
Tx ENABLE CATHODE
V
E
680
HCPL-061N
1, 0 k
5
7
6
8
RT SHIELD
Power Supplies and Bypassing
The recommended PROFIBUS
application circuit is shown in
Figure 24. Since the HCPL-x710
are fully compatible with CMOS
logic level signals, the
optocoupler is connected directly
to the transceiver. Two bypass
capacitors (with values between
0.01 and 0.1 µF) are required and
should be located as close as
possible to the input and output
power-supply pins of the
HCPL-x710. For each capacitor,
the total lead length between both
ends of the capacitor and the
power supply pins should not
exceed 20 mm. The bypass
capacitors are required because of
the high-speed digital nature of
the signals inside the optocoupler.
Being very similar to multi-station
RS485 systems, the HCPL-061N
optocoupler provides a transmit
disable function which is
necessary to make the bus free
after each master/slave
transmission cycle. Specifically,
the HCPL-061N disables the
transmitter of the line driver by
putting it into a high state mode.
In addition, the HCPL-061N
switches the RX/TX driver IC into
the listen mode. The HCPL-061N
offers HCMOS compatibility and
the high CMR performance
(1 kV/µs at VCM = 1000 V)
essential in industrial
communication interfaces.
16
www.agilent.com/semiconductors
For product information and a complete list of
distributors, please go to our web site.
For technical assistance call:
Americas/Canada: +1 (800) 235-0312 or
(916) 788-6763
Europe: +49 (0) 6441 92460
China: 10800 650 0017
Hong Kong: (+65) 6756 2394
India, Australia, New Zealand: (+65) 6755 1939
Japan: (+81 3) 3335-8152 (Domestic/Interna-
tional), or 0120-61-1280 (Domestic Only)
Korea: (+65) 6755 1989
Singapore, Malaysia, Vietnam, Thailand,
Philippines, Indonesia: (+65) 6755 2044
Taiwan: (+65) 6755 1843
Data subject to change.
Copyright © 2005 Agilent Technologies, Inc.
Obsoletes 5989-0789EN
February 28, 2005
5989-2134EN