23/06/2014 www.crouzet.com Up counters/Down - 48 x 48 - CTR48 Multicoloured LCD display (green-red) Part number 87621222 Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer Maximum input frequency 40 k Hz Simple parameter setting, configuration using text menus Easy modification of presets Scaling factor 5 A changeover relay and solid state output Removable connectors Backlit LCD display (orange) : 2 lines, 6 digits or multicoloured display (green-red) IP 65 sealed panel Option of locking the keypad, completely or partially (preset, programming) Accessories for 72 x 72 or 55 x 55 cut-out, DIN rail adaptor Part numbers 87621222 Type Functions Preset Voltages Output Multicoloured LCD display (greenred) Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer 2 24 VAC Specifications Physical details and protection Supply Relative humidity (no condensation) Altitude Certifications Vibration resistance in 3 axes Connection by screw terminals Protection Front panel watertight seal Temperature limits use (C) Temperature limits stored (C) Weight (g) 10 30 VDC / 24 V AC / 90 260 VAC EN 60068-2-30 40/93 % RLF 0 < 2000 m UL - cULus (pending) - CE 10-55 Hz/1 min/XYZ EN 60068-2-6 : 30 min. in each direction Removable Conforming to standard EN 60529 IP65 for panel/IP20 for connections -20 +65 -25 +75 150 DC version 250 AC version General characteristics Reset to zero or to preset Minimum pulse time Option to protect against reset from front panel Scale factor (each input pulse is multiplied by this figure) Scaling factor (each input impulse is divided by this value) Decimal point selectable for ease of reading Sensor supply version AC Programming and current value backed up via EEPROM memory On panel : if not locked during programming Electrical : automatic, voltage or solid state (NPN or PNP depending on programming) Impulse counter : < 15 ms Chronometer : 500 s 00,0001 99,9999 01,0000 99,9999 0 0,0 0,00 0,000 0,0000 0,00000 24 VDC -20/+15 % 50 mA Service life 10 years Operating characteristics Functions Number of presets Display Height digits (mm) Display details Preselection counter, Tachometer, Chronometer, Multi-totalizer, Batch counters, Totalizer 1 or 2 LCD with orange backlighting/Multicoloured LCD (green-red) LCD 9 - 999 999 999 999 Inputs specifications Inputs Input modes Input type High level Low level 2 counter inputs 1 reset input, 1 gate input Dir : Directional AS : up/dn AA : up/up PP : phase PP2 : phase 2 PP4 : phase 4 Voltage or solid state 8 VDC30 VDC 0 2 VDC Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 1 changeover relay, 1 NO relay, 2 solid state 23/06/2014 www.crouzet.com Solid state output characteristics Maximum current Max. voltage 30 mA 10 30 VDC for the DC version 24 VDC -20/+15 % Relay output characteristics Changeover relay NO contact Maximum current Minimum current Maximum voltage Min. voltage Response time Mechanical life (operations) Number of operations to 5 A Output modes : maintained or pulsed Depending on version 5A 10 mA 30 VDC / 250 VAC 5 VAC/DC < 13 ms 20 x 106 5 x 104 0.01 99.99 s Accessories Description Code Adaptor for 72 x 72 mm cut-out 26546842 Adaptor for 55 x 55 mm cut-out 26546846 DIN rail adaptor 26546841 Principles No Legend Current value Selected value Chronometer display Active output indication Shows which value is displayed Prog/mode button Preset control buttons Button required for programming parameters Dimensions (mm) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 No www.crouzet.com Legend 10.5 max. Dimensions (mm) 26546842 - Adaptor for 72 x 72 mm cut-out Dimensions (mm) 26546846 - Adaptor for 55 x 55 mm cut-out Dimensions (mm) Panel cut-out Dimensions (mm) 26546841 - DIN rail adaptor Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 Curves Counter : dir Inp A : counter input Inp B : count direction rS0 : Display 0 Preset rSP2 : Display Preset 0 Curves Counter : AS Inp A : Add. counter input 1 Inp B : Sub.. counter input 2 rS0 : Display 0 Preset rSP2 : Display Preset 0 Curves Counter : AA Inp A : Add. counter input 1 Inp B : Sub.. counter input 2 rS0 : Display 0 Preset Curves Counter : PP Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 www.crouzet.com A 90 B Inp A : Counter input Counting on an edge Inp B : Reversal of direction rS0 : Display 0 Preset rSP2 : Display Preset 0 Curves Counter : PP2 A 90 B Inp A : Counter input Counting on a rising edge and on a falling edge Inp B : Reversal of direction rS0 : Display 0 Preset rSP2 : Display Preset 0 Curves Counter : PP4 A 90 B Inp A : Counter input Counting on a rising edge and on a falling edge Inp B : Counter input Counting on a rising edge and on a falling edge, reversal of direction rS0 : Display 0 Preset rSP2 : Display Preset 0 Curves Chronometer : Start tcCb Inp A : No function Inp B : On/Off Cumulative time counting while B is active Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcCbb Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 Inp A : No function Inp B : On/Off Cumulative time counting Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcCAb Inp A : On Inp B : Off Cumulative time counting Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcSb Inp A : No function Inp B : On/Off Individual time counting, automatic reset before each new count Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcSbb Inp A : No function Inp B : On/Off Individual time counting, automatic reset before each new count Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcSAb Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 www.crouzet.com Inp A : On Inp B : Off Individual time counting, automatic reset before each new count Add : Display 0 Preset Sub : Display Preset 0 Curves Chronometer : Start tcAuto Inp A : No function Inp B : No function Time counting command via Reset (manual or electrical) Add : Display 0 Preset Sub : Display Preset 0 The Gate input has a display memory function Curves Tachometer : Start tA.A Inp A : Frequency input Inp B : No function Curves Tachometer : Start tA.AS Inp A : Frequency input 1 Inp B : Frequency input 2 Formula : A - B Curves Tachometer : Start tA.AA Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 Inp A : Frequency input 1 Inp B : Frequency input 2 Formula : A + B Curves Tachometer : Start tA.PP A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP rS0 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP rSA0 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP bCrSA0 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP tCrSA0 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP rSP2 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP rSAP2 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoPbCrSA2 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP tCrSA2 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP bCrS0 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP tCrS0 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP MurS0 (AA) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP bCrSP2 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP tCrSP2 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Curves Output operation : OutoP MurS0 (AS) A 90 B Inp A : Frequency input 1 Inp B : Reversal of direction Connections 87621111 / 211 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/AC : 24 VAC No Legend Sensor voltage supply (* UB interconnected) GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 - 10-30 VDC/30 mA 11-12-13 : Output 1 14-15 : Supply Connections 87621112 / 212 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/AC : 90 260 VDC No Legend Sensor voltage supply GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 - 24 VDC/30 mA 11-12-13 : Output 1 14-15 : Supply Connections 87621115 / 215 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/AC : 24 VAC No Legend Sensor voltage supply GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 - 24 VDC/30 mA 11-12-13 : Output 1 14-15 : Supply Connections 87621121 / 221 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/DC : 10 30 VDC No Legend Sensor voltage supply (* UB interconnected) GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 : 10-30 VDC/30 mA Output 2 : 10-30 VDC/30 mA 9-10 : Output 1 11-12-13 : Output 2 14-15 : Supply Connections 87621122 / 222 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/AC : 90 260 DC No Legend Sensor voltage supply GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 : 24 VDC/30 mA Output 2 : 24 VDC/30 mA 9-10 : Output 1 11-12-13 : Output 2 14-15 : Supply Connections 87621125 / 225 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 www.crouzet.com Output : 5 A/250 VAC/AC : 90 260 VDC No Legend Sensor voltage supply GND (0 VDC) INP A (signal A input) INP B (signal B input) Reset (Reset input) Gate input Output 1 : 24 VDC/30 mA Output 2 : 24 VDC/30 mA 9-10 : Output 1 11-12-13 : Output 2 14-15 : Supply Applications Programming diagram Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 23/06/2014 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 87621222