Schneider Electric Brand
s
Ultrasonic Sensors
File 9006
CONTENTS
Description Page
Selection / Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
Specifications / Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371
x
Ultrasonic Sensors
12, 18, and 30 mm Plastic Tubular
DC
©1997- 2002 Schneider Electric All Rights Reserved
370 10/02
Ultrasonic Sensors
12, 18, and 30 mm Plastic Tubular/ DC
Features:
PNP or NPN output
Housing: Plastic
Self-teach on 30 mm version
Mounting nuts included
Output
Mode
Circuit
Type
Voltage
Range
Connection
Type
Load Current
Maximum
Ultrasonic
Frequency
Catalog
Number
12 mm Diameter – Nominal Sensing Range 2" (51 mm)
N.O. PNP/NPN 12-24 Vdc 4 pin Nano 100 mA 500 kHz XX512A1KAM8
18 mm Diameter – Nominal Sensing Range 5.98" (152 mm)
N.O. PNP/NPN 12-24 Vdc 4 pin Micro 100 mA 500 kHz XX518A1KAM12
30 mm Diameter – Nominal Sensing Range 3.2" (1 m)
N.O. PNP/NPN 12-24 Vdc 4 pin Micro 100 mA 200 kHz XX630A1KAM12
Operation
During set up and operation of the XX ultrasonic sensor continually and accurately measures the elapsed
time of every pulse echo reception after each pulse transmission. The transmitted pulse starts a clock to
register the elapsed time for the received echoes. Given the elapsed time, the sensor software calculates
the distance traveled to the object of surface and back to the sensor, using a D=TVs/2, D= Distance from
the sensor to the object; T = Elapsed time between the pulse transmission and its echo reception, Vs =
the Velocity of sound, approximately 1100 feet per second.
While the sensor is in operation, the calculated distance (D) between the sensor and the object is
compared to the distances associated with the fixed window limits. These limits are shown in the
illustration above as Dwi and Dwo. If D is within these limits, an output is generated. The output remains
on until the echo does not return or it returns from outside the window limits.
Normally open operation diagrams shown below for all the XX Ultrasonic ranges.
12 mm 18 mm
30 mm
Dimensions
8 mm x 1 mm
2.29 in.
58 mm
12 mm
0.47 in.
1.5 in.
38 mm
1.95 in.
50 mm
Sensing face
12 mm x 1 mm
12 mm
12mmx1mm
18 mm x 1 m
m
2.55 in.
65 mm
2.01 in.
51 mm
0.71 in.
18 mm
2.91 in.
74 mm
Sensing face
18 mm
1.11 in.
28 mm
1.37 in.
35 mm
M30 x 1.5 mm-6g
0.79 in.
20 mm
3.73 in.
95 mm 3.33 in.
85 mm
30 mm
thread
M12X1
thread
M18X1
thread
M30X1.5
D
SHADED AREA
REPRESENTS THE
FIXED SENSING
WINDOW
PULSE Dwo
Dwi
ECHO
OBJECT
Near Limit Far Limit
Orange LED is ON
when an object is
not sensed.
Amber LED is ON
when an object is
sensed Deadband
Amber
LED
Erratic operation
within this range
Sensing Field
ON OFF
V+
BLK
(sink)
WHT
(source)
V+
BLK
(sink)
WHT
(source)
ON
OFF Orange
LED
Small objects are
best sensed about
38.1 mm (1.5")
Far Limit
50.8 mm (2.00")
Near Limit
6.3 mm (0.25")
6.4 mm
(0.25")
0.0 mm
(0.0")
Deadband
Amber
LED
Erratic operation
within this range
Fixed Sensing
Window
V+
BLK
(sink)
WHT
(source)
ON
OFF OFF
V+
BLK
(sink)
WHT
(source)
V+
BLK
(sink)
WHT
(source)
Amber LED is ON
when an object is
within window
Green LED is ON
when power is
applied
Far Limit
152.4 mm
(6.00")
Near Limit
25.4 mm
(1.00")
19.1 mm
(0.75")
0.0 mm
(0.0")
Deadband
Erratic operation
within this range
Window
Sensing Range
Red
Green Off
Yellow
LED
Multicolor
LED
Setup
Pushbutton
Connector
Multicolor LED
Red
WHT
PNP
Red LED is On when
black-wire PNP is active
BLK
PNP
WHT
PNP
BLK
PNP
WHT
PNP
BLK
PNP
WHT
PNP
BLK
PNP
Black-wire PNP is N.O.
White-wire PNP is N.C.
V+ V+ V+
V+
990.6 mm
(39.00")
50.8 mm
(2.00")
0.0 mm
(0.0")
Ultrasonic Sensors
12, 18, and 30 mm Plastic Tubular
DC, AC/DC
371
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Ultrasonic Sensors
Specifications
Mechanical
Diameter 12 mm 18 mm 30 mm
Nominal Sensing Range 2" (51 mm) 5.98" (152 mm) 3.21’ (1 m)
Sensing Zone 0.25 - 2.0" (6.4 - 50.8 mm) 1.0 - 6.0" (25.4 - 152.4 mm) 2.0 - 39.0" (51 - 991 mm)
Ultrasonic Cone Angle (see beam plots) 7 ° 10 °
Temperature Range - 4 to + 149 °F (- 20 to + 65 °C) + 32 to + 122 °F (0 to + 50 °C)
Humidity 100 %
Enclosure Rating IP67
Vibration 7 G @ 1 mm (F = 10 to 55 Hz)
Shock 30 G, 11 ms
Repeat Accuracy + / - 0.027" (0.7 mm) + / - 0.034" (0.87 mm)
Maximum Angular Deviation + / - 10 °
Minimum Size Detection 0.1" (2.5 mm) dia. rod
0.04" (1 mm) flat bar 0.06" (1.59 mm) dia. rod
Enclosure Material Case: plastic; Sensing Face: silicon rubber / except 0.47" (12 mm) glass epoxy
LED Indicators LED ring No LED Two LED’s
Electrical
Rated Supply Voltage 12 to 24 Vdc
Voltage Limits (including ripple) 10 to 28 Vdc
Maximum Load Current 100 mA
Voltage Drop; on-state 0.79 V PNP / 0.58 V NPN 0.75 V PNP / 0.67 V NPN 0.75 V PNP / 0.33 V NPN
Residual Current; open state 0.07 uA max. 0.05 uA max.
Current Consumption, no load 20 mA 60 mA 80 mA
Power Up Delay 20 ms 350 ms 720 ms
On / Off Delay 2 ms on / 2 ms off 3 ms on / 3 ms off 25 ms on / 25 ms off
Ultrasonic Frequency 500 kHz
Protection ESD Yes
Overvoltage Yes
Reverse Polarity Yes
Approvals CE
Beam Plots
The beam plots below, were developed from data collected at 20 °C and zero air flow, which defines the
boundaries and shape of the sonic beams shown for the XX ultrasonic sensor range. The boundaries
were established using a 10 cm x 10 cm target positioned parallel to the sensor face, moved in and out
of the sensors operating range.
12 mm 18 mm
30 mm
For additional cable options and lengths see p. 518
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS141 Nano Conn., 4 pin, 2 m, straight
XSZCS151 Nano Conn., 4 pin, 2 m, 90°
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4pin, 2 m, 90°
Wiring
Connector M8
12 mm
Connector M12
18 / 30 mm
24
13
3 (-)
1 (+)
4 NPN Output
2 PNP Output
12
43 3 (-)
1 (+)
4 NPN Output
2 PNP Output
BN/1
BU/3
+
BK/4
WH/2
PNP/NPN
010 40 60
-20
-10
0
10
20
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
-0.5
-0.4
-0.3
-0.2
-0.1
-0.0
0.1
0.2
0.3
0.4
0.5
mm inches
mm
inches
Deadband
20 30 50
0 5 10 15 20 25 30 35
-120
-80
-40
0
40
80
120
0123456789101112
13
-4
-3
-2
-1
0
1
2
3
4
mm
in.
cm
in.
deadband
sonic pattern measured by moving a large flat surface into the beam
110
-400
-300
-200
-100
0
100
200
300
400
0 4 8 12 16 20 24 28 32 36 40
-10
-8
-6
-4
-2
0
2
4
6
8
10
mm
inches
cm
inches
deadband
30 40 50 60 70 80 90 100
2010
0
Ultrasonic Sensors
Declaration of Conformity
©1997- 2002 Schneider Electric All Rights Reserved
372 10/02
Ultrasonic Sensors
xx
MANUFACTURER’S DECLARATION OF CONFORMITY
ALL DISTRIBUTION OR REPRODUCTION WITHOUT WRITTEN AUTHORIZATION IS FORBIDDEN. Page 1 of 1
The undersigned, representing the manufacturer Document No: R-MDOC-XX5&6-R1
Company: SQUARE D COMPANY
address: 8001 HWY 64 East
Knightdale, NC 27545-9023
USA
Herewith declares that the product(s)
Product identification: XX512A1KAM8, 12mm cylindrical ultrasonic sensor
XX518A1KAM12, 18mm cylindrical ultrasonic sensor
XX630A1KAM12, 30mm cylindrical ultrasonic sensor
To which this declaration refers are in conformity with the following:
Standards
And/Or
Normative Documents:
Low Voltage Switchgear and Controlgear,
EN60947-1: General rules
EN60947-5-2: Proximity Switches
Subject to installation, maintenance and utilization in accordance with their purpose, regulations, current
standards, manufacturer‘s instructions and industry standards. Meet(s) the provisions of the following EC
Directive(s): (Including all applicable amendments)
reference n° title
73/23/CCE
89/336/CEE
Low-voltage Directive of February 19, 1973 modified by Directive 93/68/EC of July
22, 1993.
Electromagnetic Compatibility Directive of May 3, 1989 modified by Directives
92/31/CEE of April 28, 1992 and 93/68/CEE of July 22, 1993.
The CE marking on the product and/or the packaging signifies that the product is in compliance with the
applicable EU Directives .
Location Date Authorization Signature
Raleigh, NC February 13, 2002 Name: John Gawron
Position: Director, Industrial Control Activity
Signature:
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schneider Electric:
XX518A1KAM12 XX630A1KAM12 XX512A1KAM8