Film Capacitors
Metallized Polyester Film Capacitors (MKT)
Series/Type: B32932 ... B32936
Date: July 2013
© EPCOS AG 2013. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Typical applications
For connection in series with the mains
For severe ambient conditions
Capacitive power supply applications
Energy meters
Climatic
Max. operating temperature: 105 °C
Climatic category (IEC 60068-1):
40/105/56
Features
High stability of capacitance value
X2 safety approval (up to 2.2 µF)
RoHS-compatible
Construction
Dielectric: metallized polyester
Internal series connection
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Terminals
Parallel wire leads, lead-free tinned
Standard lead lengths: 6 1 mm
Special lead lengths available on request
Marking
Manufacturer's logo, lot number,
date code, rated capacitance (coded),
capacitance tolerance (code letter),
rated AC voltage (IEC),
series number, sub-class (X2),
dielectric code (MKT), climatic category
Delivery mode
Bulk (untaped, lead length 6 - 1 mm)
Taped (Ammo pack or reel)
Approvals
Approval mark Standards Certificate
EN 60384-14
IEC 60384-14
40028058
UL 60384-14 E97863
CSA E60384-14:09 E97863
Note: X2 safety approval for C 2.2 µF
Dimensional drawing
Dimensions in mm
Lead
spacing
±0.4
Lead
diameter
d1±0.05
Type
15 0.8 B32932
22.5 0.8 B32933
27.5 0.8 B32934
37.5 1.0 B32936
Marking examples
Metallized Polyester Film Capacitors (MKT) B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 2 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types
Lead spacing 15 mm 22.5 mm 27.5 mm 37.5 mm
Type B32932 B32933 B32934 B32936
CR(µF)
0.047
0.068
0.10
0.15
0.22
0.33
0.47
0.56
0.68
0.82
1.0
1.5
2.2
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 3 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units
Lead
spacing
mm
CR
µF
Max. dimensions
w×h×l
mm
Ordering code
(composition see
below)
Ammo
pack
pcs./MOQ
Straight
terminals,
Reel
pcs./MOQ
Straight
terminals,
Untaped
pcs./MOQ
X2
safety
appr.
X = approval granted
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
M = ±20%
K = ±10%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
000 = Straight terminals, Untaped (standard lead
length 6 1 mm)
15 0.047 5.0 ×10.5 ×18.0 B32932A3473+*** 4680 5200 4000 X
0.068 5.0 ×10.5 ×18.0 B32932A3683+*** 4680 5200 4000 X
0.10 6.0 ×11.0 ×18.0 B32932A3104+*** 3840 4400 4000 X
0.15 7.0 ×12.5 ×18.0 B32932A3154+*** 3320 3600 4000 X
0.22 8.5 ×14.5 ×18.0 B32932A3224+*** 2720 2800 2000 X
0.33 9.0 ×17.5 ×18.0 B32932A3334+*** 2560 2800 2000 X
0.47 11.0 ×18.5 ×18.0 B32932A3474M*** 2200 1200 X
22.5 0.10 6.0 ×15.0 ×26.5 B32933A3104+*** 2720 2800 2880 X
0.15 6.0 ×15.0 ×26.5 B32933A3154+*** 2720 2800 2880 X
0.22 7.0 ×16.0 ×26.5 B32933A3224+*** 2320 2400 2520 X
0.33 7.0 ×16.0 ×26.5 B32933A3334+*** 2320 2400 2520 X
0.47 8.5 ×16.5 ×26.5 B32933A3474M*** 1920 2000 2040 X
0.47 10.5 ×16.5 ×26.5 B32933B3474+*** 1560 1600 2160 X
0.56 10.5 ×16.5 ×26.5 B32933A3564+*** 1560 1600 2160 X
0.68 10.5 ×18.5 ×26.5 B32933A3684+*** 1560 1600 2160 X
0.82 12.0 ×22.0 ×26.5 B32933A3824+*** 1800 X
1.0 12.0 ×22.0 ×26.5 B32933A3105M*** 1800 X
1.0 14.5 ×29.5 ×26.5 B32933B3105+*** 1040 X
1.5 14.5 ×29.5 ×26.5 B32933A3155+*** 1040 X
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 4 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units
Lead
spacing
mm
CR
µF
Max. dimensions
w×h×l
mm
Ordering code
(composition see
below)
Ammo
pack
pcs./MOQ
Straight
terminals,
Reel
pcs./MOQ
Straight
terminals,
Untaped
pcs./MOQ
X2
safety
appr.
X = approval granted
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
M = ±20%
K = ±10%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
000 = Straight terminals, Untaped (standard lead
length 6 1 mm)
27.5 0.47 11.0 ×19.0 ×31.5 B32934A3474+*** 1400 1280 X
0.56 11.0 ×19.0 ×31.5 B32934A3564+*** 1400 1280 X
0.68 11.0 ×19.0 ×31.5 B32934A3684+*** 1400 1280 X
0.82 11.0 ×19.0 ×31.5 B32934A3824+*** 1400 1280 X
1.0 11.0 ×19.0 ×31.5 B32934A3105M*** 1400 1280 X
1.0 11.0 ×21.0 ×31.5 B32934B3105+*** 1400 1280 X
1.5 13.5 ×23.0 ×31.5 B32934B3155M*** 1200 1120 X
1.5 14.0 ×24.5 ×31.5 B32934D3155+*** 1040 X
2.2 18.0 ×27.5 ×31.5 B32934B3225+*** 800 X
37.5 1.0 12.0 ×22.0 ×41.5 B32936A3105+*** 1620 X
1.5 12.0 ×22.0 ×41.5 B32936A3155+*** 1620 X
2.2 14.0 ×25.0 ×41.5 B32936A3225+*** 1380 X
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 5 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Technical data
Max. operating temperature Top,max
(Top = Tamb + self-heating)
+105 °C
Dissipation factor tan δ(in 10-3)
at 20 °C (upper limit values)
tan δ1 kHz 10 kHz
C1µF 8 15
C>1µF 8
Insulation resistance Rins
or time constant τ= CRRins
at 20 °C,
rel. humidity 65% (minimum
as-delivered values)
CR0.33 µF CR> 0.33 µF
30000 M10000 s
DC test voltage 1312 V DC, 2 s (4.3 VRaccording to IEC 60384-14)
Passive flammability category
to IEC 40 (CO) 752
B
Capacitance tolerances
(measured at 1 kHz) ±10% (K), ±20% (M)
Rated AC voltage ( IEC 60384-14 ) 305 V (50/60 Hz)
Operating voltage Vop at high
temperature
TA105 °C Vop = 1.25 VAC (1000 h)
Damp heat test Test conditions
1. Temperature:
Relative humidity (RH):
Test duration:
Voltage value:
+85 °C±2°C
85% ±2%
1000 hours
240 V AC, 50 Hz
2. Temperature:
Relative humidity (RH):
Test duration:
Voltage value:
+40 °C±2°C
93% ±2%
1000 hours
240 V AC, 50 Hz
Limit values after damp heat test Capacitance change (C/C):
Dissipation factor change
(tan δ):
10%
510-3 (at 1 kHz)
Insulation resistance Rins
or time constant τ= CRRins:50% of initial limit
Reference standard AEC-Q200
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 6 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k0values
Lead spacing (mm) 15 22.5 27.5 37.5
dV/dt (V/µs) 90 50 35 25
k0(V2/µs) 108000 60000 42000 30000
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 7 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Mounting guidelines
1 Soldering
1.1 Solderability of leads
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far
higher than the upper category temperature of the capacitors, the terminal wires should be cut off
from the capacitor before the ageing procedure to prevent the solderability being impaired by the
products of any capacitor decomposition that might occur.
Solder bath temperature 235 ±5°C
Soldering time 2.0 ±0.5 s
Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane
Evaluation criteria:
Visual inspection Wetting of wire surface by new solder 90%, free-flowing solder
1.2 Resistance to soldering heat
Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A.
Conditions:
Series Solder bath temperature Soldering time
MKT boxed (except 2.5 ×6.5 ×7.2 mm)
coated
uncoated (lead spacing > 10 mm)
260 ±5°C 10 ±1 s
MFP
MKP (lead spacing > 7.5 mm)
MKT boxed (case 2.5 ×6.5 ×7.2 mm) 5±1 s
MKP
MKT
(lead spacing 7.5 mm)
uncoated (lead spacing 10 mm)
insulated (B32559)
<4s
recommended soldering
profile for MKT uncoated
(lead spacing 10 mm) and
insulated (B32559)
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 8 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane
Shield Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor
body and liquid solder
Evaluation criteria:
Visual inspection No visible damage
C/C0
2% for MKT/MKP/MFP
5% for EMI suppression capacitors
tan δAs specified in sectional specification
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 9 of 16Please read Cautions and warnings and
Important notes at the end of this document.
1.3 General notes on soldering
Permissible heat exposure loads on film capacitors are primarily characterized by the upper cate-
gory temperature Tmax. Long exposure to temperatures above this type-related temperature limit
can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical
characteristics. For short exposures (as in practical soldering processes) the heat load (and thus
the possible effects on a capacitor) will also depend on other factors like:
Pre-heating temperature and time
Forced cooling immediately after soldering
Terminal characteristics:
diameter, length, thermal resistance, special configurations (e.g. crimping)
Height of capacitor above solder bath
Shadowing by neighboring components
Additional heating due to heat dissipation by neighboring components
Use of solder-resist coatings
The overheating associated with some of these factors can usually be reduced by suitable coun-
termeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced
cooling process may possibly have to be included.
EPCOS recommends the following conditions:
Pre-heating with a maximum temperature of 110 °C
Temperature inside the capacitor should not exceed the following limits:
MKP/MFP 110 °C
MKT 160 °C
When SMD components are used together with leaded ones, the leaded film capacitors should
not pass into the SMD adhesive curing oven. The leaded components should be assembled af-
ter the SMD curing step.
Leaded film capacitors are not suitable for reflow soldering.
Uncoated capacitors
For uncoated MKT capacitors with lead spacings 10 mm (B32560/B32561) the following mea-
sures are recommended:
pre-heating to not more than 110 °C in the preheater phase
rapid cooling after soldering
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 10 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Cautions and warnings
Do not exceed the upper category temperature (UCT).
Do not apply any mechanical stress to the capacitor terminals.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after it has been soldered to the PC board.
Do not pick up the PC board by the soldered capacitor.
Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified
lead spacing.
Do not exceed the specified time or temperature limits during soldering.
Avoid external energy inputs, such as fire or electricity.
Avoid overload of the capacitors.
The table below summarizes the safety instructions that must always be observed. A detailed de-
scription can be found in the relevant sections of the chapters "General technical information" and
"Mounting guidelines".
Topic Safety information Reference chapter
"General technical
information"
Storage conditions Make sure that capacitors are stored within the
specified range of time, temperature and humidity
conditions.
4.5
"Storage conditions"
Flammability Avoid external energy, such as fire or electricity
(passive flammability), avoid overload of the
capacitors (active flammability) and consider the
flammability of materials.
5.3
"Flammability"
Resistance to
vibration
Do not exceed the tested ability to withstand
vibration. The capacitors are tested to
IEC 60068-2-6.
EPCOS offers film capacitors specially designed
for operation under more severe vibration regimes
such as those found in automotive applications.
Consult our catalog "Film Capacitors for
Automotive Electronics".
5.2
"Resistance to vibration"
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 11 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Topic Safety information Reference chapter
"Mounting guidelines"
Soldering Do not exceed the specified time or temperature
limits during soldering.
1 "Soldering"
Cleaning Use only suitable solvents for cleaning capacitors. 2 "Cleaning"
Embedding of
capacitors in
finished assemblies
When embedding finished circuit assemblies in
plastic resins, chemical and thermal influences
must be taken into account.
Caution: Consult us first, if you also wish to
embed other uncoated component types!
3 "Embedding of
capacitors in finished
assemblies"
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications and the website of EPCOS, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the
specifications of the respective products. Detailed information can be found on the Internet
under www.epcos.com/orderingcodes.
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 12 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Symbols and terms
Symbol English German
αHeat transfer coefficient Wärmeübergangszahl
αCTemperature coefficient of capacitance Temperaturkoeffizient der Kapazität
A Capacitor surface area Kondensatoroberfläche
βCHumidity coefficient of capacitance Feuchtekoeffizient der Kapazität
C Capacitance Kapazität
CRRated capacitance Nennkapazität
C Absolute capacitance change Absolute Kapazitätsänderung
C/C Relative capacitance change (relative
deviation of actual value)
Relative Kapazitätsänderung (relative
Abweichung vom Ist-Wert)
C/CRCapacitance tolerance (relative deviation
from rated capacitance)
Kapazitätstoleranz (relative Abweichung
vom Nennwert)
dt Time differential Differentielle Zeit
t Time interval Zeitintervall
T Absolute temperature change
(self-heating)
Absolute Temperaturänderung
(Selbsterwärmung)
tan δAbsolute change of dissipation factor Absolute Änderung des Verlustfaktors
V Absolute voltage change Absolute Spannungsänderung
dV/dt Time differential of voltage function (rate
of voltage rise)
Differentielle Spannungsänderung
(Spannungsflankensteilheit)
V/t Voltage change per time interval Spannungsänderung pro Zeitintervall
E Activation energy for diffusion Aktivierungsenergie zur Diffusion
ESL Self-inductance Eigeninduktivität
ESR Equivalent series resistance Ersatz-Serienwiderstand
f Frequency Frequenz
f1Frequency limit for reducing permissible
AC voltage due to thermal limits
Grenzfrequenz für thermisch bedingte
Reduzierung der zulässigen
Wechselspannung
f2Frequency limit for reducing permissible
AC voltage due to current limit
Grenzfrequenz für strombedingte
Reduzierung der zulässigen
Wechselspannung
frResonant frequency Resonanzfrequenz
FDThermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur
Diffusion
FTDerating factor Deratingfaktor
i Current (peak) Stromspitze
ICCategory current (max. continuous
current)
Kategoriestrom (max. Dauerstrom)
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 13 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Symbol English German
IRMS (Sinusoidal) alternating current,
root-mean-square value
(Sinusförmiger) Wechselstrom
izCapacitance drift Inkonstanz der Kapazität
k0Pulse characteristic Impulskennwert
LSSeries inductance Serieninduktivität
λFailure rate Ausfallrate
λ0Constant failure rate during useful
service life
Konstante Ausfallrate in der
Nutzungsphase
λtest Failure rate, determined by tests Experimentell ermittelte Ausfallrate
Pdiss Dissipated power Abgegebene Verlustleistung
Pgen Generated power Erzeugte Verlustleistung
Q Heat energy Wärmeenergie
ρDensity of water vapor in air Dichte von Wasserdampf in Luft
R Universal molar constant for gases Allg. Molarkonstante für Gas
R Ohmic resistance of discharge circuit Ohmscher Widerstand des
Entladekreises
RiInternal resistance Innenwiderstand
Rins Insulation resistance Isolationswiderstand
RPParallel resistance Parallelwiderstand
RSSeries resistance Serienwiderstand
S severity (humidity test) Schärfegrad (Feuchtetest)
t Time Zeit
T Temperature Temperatur
τTime constant Zeitkonstante
tan δDissipation factor Verlustfaktor
tan δDDielectric component of dissipation
factor
Dielektrischer Anteil des Verlustfaktors
tan δPParallel component of dissipation factor Parallelanteil des Verlfustfaktors
tan δSSeries component of dissipation factor Serienanteil des Verlustfaktors
TAAmbient temperature Umgebungstemperatur
Tmax Upper category temperature Obere Kategorietemperatur
Tmin Lower category temperature Untere Kategorietemperatur
tOL Operating life at operating temperature
and voltage
Betriebszeit bei Betriebstemperatur und
-spannung
Top Operating temperature Beriebstemperatur
TRRated temperature Nenntemperatur
Tref Reference temperature Referenztemperatur
tSL Reference service life Referenz-Lebensdauer
VAC AC voltage Wechselspannung
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 14 of 16Please read Cautions and warnings and
Important notes at the end of this document.
Symbol English German
VCCategory voltage Kategoriespannung
VC,RMS Category AC voltage (Sinusförmige)
Kategorie-Wechselspannung
VCD Corona-discharge onset voltage Teilentlade-Einsatzspannung
Vch Charging voltage Ladespannung
VDC DC voltage Gleichspannung
VFB Fly-back capacitor voltage Spannung (Flyback)
ViInput voltage Eingangsspannung
VoOutput voltage Ausgangssspannung
Vop Operating voltage Betriebsspannung
VpPeak pulse voltage Impuls-Spitzenspannung
Vpp Peak-to-peak voltage Impedance Spannungshub
VRRated voltage Nennspannung
RAmplitude of rated AC voltage Amplitude der Nenn-Wechselspannung
VRMS (Sinusoidal) alternating voltage,
root-mean-square value
(Sinusförmige) Wechselspannung
VSC S-correction voltage Spannung bei Anwendung "S-correction"
Vsn Snubber capacitor voltage Spannung bei Anwendung
"Beschaltung"
Z Impedance Scheinwiderstand
Lead spacing Rastermaß
B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Page 15 of 16Please read Cautions and warnings and
Important notes at the end of this document.
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-
tailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK,
MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other coun-
tries. Further information will be found on the Internet at www.epcos.com/trademarks.
Important notes
Page 16 of 16