2
Characteristic
Optical characteristic
Environmental characteristic Mechanical characteristics
Attenuation
Return loss
Rated input power
Controlled Operating
Environment
Uncontrolled Operating
Environment
Non-Operating
Environment
Humidity/Condensation
Cycling Test
Water Immersion
Vibration
Side Pull Load
Cable Retention
Durability
Impact Test
Measurement at a point within the wavelength of 1310 ±30
nm and a point within the wavelength of 1550 ±30 nm.
Power : 250mW(LD)
Wavelength : 1470nm
Duration : 100 hours
Temperature : -5ç to 50ç
Duration : 182.5 hours
Humidity : 15% to 90%
Temperature : -40ç to 75ç
Period of 1 cycle : 8 hours
Number of cycles
: 21
Low-Temperature Exposure and Thermal Shock
Temperature :
23
ç
➝40
ç
➝
-
40
ç
➝23ç
Duration : 2.1h 72 h 5 min.
minimum
High-Temperture Exposure and Thermal Shock
Temperature :
23
ç
➝70
ç
➝
70ç
➝23ç
Duration : 1.6h 72 h 5 min.
minimum
High Relative Humidity Exposure
Temperature :
23
ç
➝40
ç
➝
40ç
➝23ç
Duration : 0.6h 96 h 0.6h
Humidity : 90% to 95%
Temperature : -10ç to 65ç
Period of 1 cycle : 12 hours
Humidity : 90% to 100%
Number of cycles
: 14
Temperature : 43ç
Duration : 168 hours
Solution : PH 5.5
Vibration frequency range
: 10 to 55 Hz
Maximum amplitude
: 1.52 mm
Duration : 2 hours in each of 3 directions
Bend angle : 90°
Load : 1.25 kg
Load : 2 kg
Insertion/withdrawal cycles
: 200
Drop onto a concrete floor from a height of 1.8 m.
Cycles: 8 times in each of 3 directions
1) After test, change in attenuation(fluctuation)and return loss shall be
1) as follows.
1) • Attenuation(fluctuation) : within 0.5 dB
1) • Return loss : 60 dB min.
2) No breakage, crack or dislocation of components.
Refer to the various types of attenuation tolerance (the previous page).
60 dB min.
After / during test, changing in attenuation(fluctuation)shall be less than
±0.1dB.
1) After /during test, change in attenuation(fluctuation)and return loss
1) shall be as follows.
1) • Attenuation(fluctuation) : within 0.5 dB
1) • Return loss : 60 dB min.
2) No breakage, crack or dislocation of components.
1) After test, change in attenuation(fluctuation)and return loss shall be
1) as follows.
1) • Attenuation(fluctuation) : within 0.5 dB
1) • Return loss : 60 dB min.
2) No breakage, crack or dislocation of components.
Test Method (Conforms with Telcordia GR-910-CORE)
Specification
Component Material
Body
Ferrule
Split sleeve
Zinc alloy
Zirconia
Zirconia
■Materials and Dimensions
Serial No.