4
M63954P
HVIC Half-Bridge Driver
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical Characteristics, HGND = GND, HVCC = VCC = 15V, Ta = 25°C, unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Connection Detect
LN Input Voltage Limit VLN 1—V
CC-1.5 Volts
LNTH Input Voltage Limit VLNTH 1—V
CC-1.5 Volts
LN Offset Voltage VLNIO -50 — 50 mV
LN Input Leak Current ILN VLN < VLNTH -1.0 -0.22 — µA
LNTH Input Leak Current ILNTH VLN > VLNTH, VCC < VUVr -1.0 -0.22 — µA
LNTH Input Hysteresis Current ILNTHh VLN > VLNTH, VLNTH = 5V 20 40 80 µA
LN Response Delay Time tLN 14 — 100 µs
Abnormal Detect
AB Input Voltage Limit VAB 0—V
REG-1.5 Volts
ABTH Input Voltage Limit VABTH 0—V
REG-1.5 Volts
AB Offset Voltage VABIO -50 — 50 mV
AB Input Leak Current IAB VAB < VABTH -0.5 -0.08 — µA
ABTH Input Leak Current IABTH VAB > VABTH -0.5 -0.08 — µA
AB Response Delay Time tAB 30 — 150 µs
External CNT
CNT Input Threshold Voltage VCNT 3.4 3.6 3.8 Volts
CNT Input Hysteresis Voltage VCNTh 0.8 1.0 1.2 Volts
CNT Input Leak Current ICNT VCNT = 0V -0.5 -0.08 — µA
CNT Response Delay Time tCNT 30 — 150 µs
Driver
Floating Supply Leak Current IRFC VHGND = 600V — — 2.0 µA
Dead Time tDEAD C = 1000pF 1.0 — 1.9 µs
HO Output Voltage VHOH1 IHO = 0mA 14.0 14.4 — Volts
VHOH2 IHO = -20mA 10 13 — Volts
VHOH3 IHO = -200mA 1.0 5.5 — Volts
VHOL1 IHO = 0mA — 5 100 mV
VHOL2 IHO = 20mA — 0.5 1.0 Volts
VHOL3 IHO = 200mA — 6 12 Volts
LO Output Voltage VLOH1 ILO = 0mA 14.0 14.4 — Volts
VLOH2 ILO = -20mA 10 13 — Volts
VLOH3 ILO = -200mA 1.0 5.5 — Volts
VLOL1 ILO = 0mA — 5 100 mV
VLOL2 ILO = 20mA — 0.5 1.0 Volts
VLOL3 ILO = 200mA — 6 12 Volts
Output Rise Time trAmplitude 10% → 90%, C = 1000pF — 50 120 ns
Output Fall Time tfAmplitude 90% → 10%, C = 1000pF — 50 120 ns