F3SJ-A R C US Options n n safety light curtains D F3SJ-A Safety Light Curtain n n n n Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent on minimum object resolution and protected height n Cascaded designs possible - 4 segments, up to 400 beams n Warning zone function n Partial muting n Position detection muting n Fixed blanking Protected heights: 14 mm protected heights from 245 to 1631 mm (9.6 to 64 in.), 20 mm and 30 mm protected heights from 245 to 2495 mm (9.6 to 98 in.), 55 mm from 270 to 2470 mm (10.6 to 97 in.) n Very compact size - 30 x 24 mm (1.18 x 0.94 in.) Floating blanking - up to four beams n External Device Monitoring n Two PNP safety outputs n One NPN auxiliary output n Cross-talk prevention n Range selection Handheld setting console SD manager programming software n F3SP/F3SX Safety Controller n Weld shields n IP67 enclosures n Multiple mounting options n Description The F3SJ-A system is a fullfeatured safety light curtain that meets demanding and complex guarding requirements. Inside its compact housing the F3SJ-A combines several features which allow it to be used in a variety of ways. These features include a warning zone function, as well as fixed and floating blanking. Also included is a valuable feature known as "partial muting". For complete safety, External Device Monitoring (EDM) is included and cross-talk prevention features are standard. For ease of use, the F3SJ-A can be configured by using either a handheld setting console or by connecting to a computer running the convenient and comprehensive SD Manager programming software. A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D For the Latest Information On the Internet: www.sti.com or www.omron.ca Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A The safety light curtain beams in all areas other than where the workpiece passes through are constantly ON. Warning Zone Function With the F3SJ-A part of the detection zone can be used as warning zone to generate an alarm when someone approaches the danger zone. If the person then enters the danger zone the F3SJ-A will send a stop signal to the guarded machine. In addition, the auxiliary output can be used to activate a flashing lamp to alert the person in the warning zone. The detection zone for a single F3SJ-A can be divided into two zones or set a single warning zone for multiple, cascaded F3SJ-A units. Convenient Serial Connection Sensors with protected heights connection of almostSeries 2.5 m arecable available. If up to 15 m long you want 25 tommmake changes in the future, you can always extend the protective height with series connections. Up to four sets (400 20 mm gap between end beamsconnected when beams) can be series connected side by side and with series-connection cables up to 15 m in length, applications can cover a wide area. Approx. 2.5 m (100 beams) Dividing the zone between series-connected sensors Detection zone Total length: Approx. 10 m (400 beams) Only the beams of the safety light curtain interrupted by the workpiece are muted. Position detection muting is used in applications where the workpiece is set in position each time by an operator, and a turntable or positioning robot then moves the workpiece to the area where the work is performed. A limit switch or other means is used to detect when the robot is in a safe position and muting is then applied. Warning zone A single sensor can also be divided Detection zone Series connection cable up to 15 m long 25 mm Warning zone Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 20 mm gap between end beams when connected side by side For the Latest Information Approx. 2.5 m (100 beams) On the Internet: www.sti.com or www.omron.ca D D safety light curtains Muting Functions Muting temporarily disables the F3SJ-A when an object must pass through the detection zone, such as when supplying a workpiece to your equipment. Partial muting increases the level of safety by only muting the beams of the safety light curtain where the workpiece passes through, while preventing muting in all other areas. F3SJ-A n Description (continued) "SD Manager" PC Setting Software safety light curtains D Programming Options Using the SD Manager software, all features of the F3SJ-A can be set and checked. Features include: n Display of system specifications: - Model - Number of beams - Minimum object resolution - Response time n Settings for: - Fixed blanking - Floating blanking - Warning zone configuration - Muting - Both partial and position detection - External indicator function - Auxiliary outputs - EDM parameters - Operating range n Monitoring of received and ambient light intensity n Maintenance information: - Power on time - OSSD switching frequency n Recovery of settings n Safety distance calculations based on parameters for connected system When you don't want to take a computer into the field with you the F39-MC21 setting console is a convenient way to set parameters and check the system status. F39-GWUM "SD Manager" PC Setting Software F3SJ-A To a USB terminal Branch Connector Connection Cable All parameters can be set and the system status can be checked with a personal computer. In addition to making it easy to monitor the beam alignment, the ambient incident light intensity can be displayed in bar graph form for an easy check of the system status. Setting Console F39-MC21 Setting Console for the F3SJ-A A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D For the Latest Information On the Internet: www.sti.com or www.omron.ca Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A n Applications Selecting the Best Configuration Space Efficient and Low Cost The built-in external device monitoring function eliminates the need for a safety relay unit. D No Safety Relay Unit F39-JC(R)A G7SA A welded contact detection circuit can be created using two force-guided relays. Contactor safety light curtains With built-in muting and blanking functions, the F3SJ-A is can be employed in a wide variety of applications from robotic work cells to small machines. The potential for cascaded design and a broad selection of minimum object resolutions adds to this versatility. Motor Reduced Wiring and Easy Maintenance Cables with connectors on both ends simplify connections and prevent wiring errors. Connector Type F39-JC(R)B F3SP-B1P Dedicated controller Contactor Motor Multi-input Safety Circuit Configuration When an emergency stop or door switch is used in conjunction with the F3SJ-A, the safety circuit becomes more complex. The F3SX safety controller is one possible solution. Four models are available to match your desired inputs and outputs. Use an F39-CN5 branch connector to significantly reduce the time required to make the proper connections. F39-JC(R)T Connector cable for F3SX use Emergency stop switch Branch connector F39-ON5 F3SX Relays with force-guided contacts Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 F39-JC(R)B Connector cable for F3SX use For the Latest Information On the Internet: www.sti.com or www.omron.ca D F3SJ-A n Wiring Wiring for Single F3SJ-A Application Detection of a welded relay contact is possible without a controller relay unit. D * Manual reset mode safety light curtains Emitter Receiver F39-JC@A-L * Using external device monitoring function F39-JC@A-D KM1 KM2 Shield 0 V (Blue) KM1 Control output 2 (White) Control output 1 (Green) Auxiliary output 1 (Yellow) External device monitoring input (Red) Communication line (-) (Pink) KM4 +24 V (Brown) +24 V (Brown) Interlock selection input (White) Reset input (Yellow) Test input (Green) S2 S1 Auxiliary output 2 (Red) 0 V (Blue) Shield Communication line (+) (Gray) KM1 KM2 KM2 KM3 +24 VDC IN OUT M E1 0V PLC Light incident Light interrupted External test switch (S1) Reset switch (S2) Control output KM1,KM2 N.O. contact KM1,KM2 N.C. contact PLC input (See note.) PLC output Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D10 A For the Latest Information On the Internet: www.sti.com or www.omron.ca Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A Wiring Connection with an F3SX-E-L2R Controller (Category 4) An emergency stop switch, door switch, two-hand control, single beam or relay unit can be used in conjunction with the F3SX. Various settings can be changed and input/output terminals can be monitored using the setting support software for F3SX. L2 Module 2 8 6 1 3 4 5 7 12 10 F3SJ (1st unit) Emitter 9 11 16 14 13 * Auto reset mode * External device monitoring function disabled Model F39-JC@A-L cable for emitter Wiring for auto reset mode F3SX-E-L2R settings Model F39-JC@A-D cable for receiver * Manual reset mode 0 V (Blue) Shield Control output 1 (White) 24 VDC (Brown) Main Module Control output 1 (Green) * Using feedback time monitoring function Communication line (-) (Pink) External device monitoring input (Red) (See note 2.) Auxiliary output 1 (Yellow) Y3 24 VDC (Brown) E1 Y2 Reset input (Yellow) Shield 24 VDC Interlock selection input (White) 0 V (Blue) S2 Auxiliary output 2 (Red) Open Test input (Green) Communication line (+) (Gray) Y1 safety light curtains 15 D F3SJ-A settings Receiver Wiring when safety light curtain F3SJ is not used Relay Output Module (R Module) 11 21 12 22 S2 S1: Emergency stop switch (direct opening contacts) (A165E, A22E) S2: Reset switch KM1, KM2: Magnetic contactor (LC1D) RY1, RY2: Relay M: 3-phase motor E1: 24 VDC power supply (S82K) Note: 1. This wiring example is for category 4. 2. This example shows the connection when auxiliary output 1 is in the standard setting (ON when light is interrupted). 3. When the F3SJ-A is seriesconnected, or 5 or more sets are connected to the total system of the F3SX, power must be supplied to the F3SJ-A from external source. For details, see the F3SX installation manual. S1 Fuse 24 VDC E1 T12 T21 T22 Y1 Y2 Y3 2 8 6 1 3 4 5 11 7 Control Circuit 23 33 K1 24 VDC 24 VDC E1 AC COM 24 VDC K2 0V A2 SSC AS3 AS2 AS1 SS1 SS2 RY1 RY2 FB 15 9 11 16 14 13 12 10 12 E1 24 VDC 24 VDC E1 24 34 KM1 KM2 (operation command) Motor controller RY1 KM1 Communication line (-) (Pink) Communication line (+) (Gray) Shield 0 V (Blue) Control output 2 (White) Control output 1 (Green) External device monitoring input (Red) (See note 2.) (See note 2.) Auxiliary output 1 (Yellow) 24 VDC (Brown) Emitter Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 F3SJ (2nd unit) Open (Red) 0 V (Blue) Shield Test SW Reset input (Yellow) Wiring when F3SJ's testing function is used Model F39-JC@A-D cable for receiver Model F39-JC@A-L cable for emitter Test input (Green) 24 VDC (Brown) Reset input (Yellow) Interlock selection input (White) Shield 0 V (Blue) M Auxiliary output 2 (Red) Open Test input (Green) RY2 KM2 24 VDC (Brown) T11 Interlock selection input (White) A1 Receiver For the Latest Information On the Internet: www.sti.com or www.omron.ca D11 F3SJ-A n Wiring (continued) Wiring Connection with a G9SX-AD322-T15 Controller (Category 4) F3SJ-A settings D Emitter * Auto reset mode Receiver safety light curtains * External device monitoring function disabled G9XS-AD322-T15 settings * Auto reset mode F39-JC@A-L * Using feedback loop F39-JC@A-D 0 V (Blue) Feedback loop KM1 Shield Control output 2 (White) Auxiliary output 1 (Yellow) Communication line (-) (Pink) Control output 1 (Green) +24 V (Brown) External device monitoring input (Red) +24 V (Brown) Interlock selection input (White) Reset input (Yellow) S2 0 V (Blue) Shield Auxiliary output 2 (Red) Open S1 Test input (Green) Communication line (+) (Gray) KM2 Motor controller KM3 KM4 +24 V A1 +24 VDC E1 0V T11 T12 T21 T22 Open Open +24 V T31 T32 T33 Y1 KM1 KM3 KM2 KM4 S34 AND M1 T41 T42 Open Open M2 OFF Control circuit A2 S14 S24 S34 S44 S54 L1 KM1 KM2 Wiring for manual reset mode Feedback loop KM3 KM4 X1 X2 G9SX-AD322-T15 PLC, etc. Motor controller (operation command) S1: External test switch (connect to 0 V if the switch is not necessary) S2: Lockout reset switch (connect 24 V if the switch is not necessary) KM1 to KM4: Magnetic contactor M1, M2: 3-phase motor E1: 24 VDC power supply (S82K) PLC: Programmable controller (used for monitoring, not related to safety system) Control output KM1,KM2 N.C. contact KM3,KM4 N.C. contact KM1 KM1,KM2 N.O. contact S3 KM2 KM3,KM4 N.O. contact KM3 Motor operation command KM4 Motor rotation +24 V OFF-delay time T31 T32 T33 Y1 S3: Reset switch Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D12 A For the Latest Information On the Internet: www.sti.com or www.omron.ca Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A n Specifications Peformance Resolution: 14 mm, 20 mm, 30 mm, 55 mm Protected Height: 14 mm - 245 to 1631 mm (9.6 to 64.2 in.) 20 mm and 30 mm - 245 to 2495 mm (9.6 to 98.2 in.) 55 mm - 270 to 2470 mm (10.6 to 97.2 in.) D Operating Range: 0.2 to 9 m for: 14 mm (all protected heights) 20 mm resolution up to 1505 mm (59.3 in.) protected height 30 mm and 55 mm resolution up to 1620 mm (63.8 in.) protected height safety light curtains 0.2 to 7 m for: 20 mm resolution 1655 to 2495 mm (65.2 to 98.2 in.) protected height 30 mm resolution 1745 to 2495 mm (68.7 to 98.2 in.) protected height 55 mm resolution 1670 to 2470 mm (65.7 to 97.2 in.) protected height Effective Aperture Angle: 2.5 maximum, transmitter and receiver at operating range greater than 3 m (9.8 ft.) Response Time: For 14 mm resolution systems up to 983 mm (38.7 in.) protected height 17.5 ms For 14 mm resolution systems above 983 mm (38.7 in.) protected height 25 ms For 20 mm resolution systems up to 1205 mm (47.4 in.) protected height 15 ms For 20 mm resolution systems above 1205 mm (47.4 in.) protected height 22.5ms For 30 mm resolution systems, all protected heights 17.5 ms For 55 mm resolution systems, all protected heights 13 ms Safety Output Rating: Two PNP outputs sourcing 300 mA max. Auxiliary (Non-Safety) Output Ratings: One PNP output sourcing 300 mA max. Light Source: Infrared LED, 870 nm Light Source Life: NA Indicators: Transmitter: 5 LED Light Level Indicators, 3 LED Error Indicators, Power, Interlock, EDM, Blanking/Test Receiver: 5 LED Light Level Indicators, 3 LED Error Indicators, Machine Run, Machine Stop Mechanical Enclosure: Anodized aluminum housing Cable Length: Optional cables are available up to 20 m(65.6 ft.) in length Transmitter and Receiver Cable Connections: M12, 8-pin Electrical Power Supply: 24 VDC Environmental Protection Rating: IP65 Operating Temperature: -10 to 55C (14 to 131F) Storage Temperature: -30 to 70C (-22 to 158F) Relative Humidity: 35 to 85% non-condensing Vibration: 10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions Shock: 100 m/s2, 1000 times each in X, Y and Z directions Conformity/Approvals Approvals: All F3SJ-A systems have been EC type examined to the requirements of IEC 61496-1, -2 for a Type 4 ESPE Conforming to Standards: ANSI/RIA R15.06-1999; ANSI B11.19-2003; OSHA 1910.217(c); OSHA 1910.212.A Specifications are subject to change without notice. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com or www.omron.ca D13 F3SJ-A n Specifications (continued) Control Unit Power Supply Voltage: 24 VDC 10% Power Consumption: DC1.7 W max (not including sensor's current consumption) Operation Time: 100 ms max. (not including the sensor's response time) safety light curtains D Response Time: 10 ms max. (not including the sensor's response time) Relay Output Number of Contacts: 3 N/O + 1 N/C Rated Load: 25 VAC 5 A (cos = 1); 30 VDC 5 A L/R = 0 ms Rated Current: 5 A Connection Type Between Sensors: M12 connector (8-pin) Others: Terminal block Weight: Approx. 280 g (9.9 oz.) Specifications are subject to change without notice. A Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D14 For the Latest Information On the Internet: www.sti.com or www.omron.ca Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A n Dimensions -- mm 2-Top/bottom mounting brackets 5.5 2-Mounting holes 30 20 Mounting Screw Holes (13.75) 4-M5 20 16.5 1 3.75 D 6.25 safety light curtains 30 24 31 22 7 Intermediate mounting bracket 22 2-M5 5.5 B D 53 A B 42 42 C (Protective height) 2-Mounting holes Beam 10 E E 4-Mounting holes 37 300 6 dia. 43 15 dia. 13.75 6.5 dia. 2-Mounting holes 9 dia. M12 Waterproof connector C (protective height) = 4-digit number in the table A = C + 74 B = C + 46.5 D = C - 20 E = see chart below Protective Height 26 46 Number of Intermediate Brackets E* 245 to 596 mm (9.6 to 23.5 in.) 0 -- 600 to 1130 mm (23.6 to 44.5 in.) 1 E = B/2 1136 to 1658 mm (44.7 to 65.3 in.) 2 E = B/3 1660 to 2180 mm (65.4 to 85.8 in.) 3 E = B/4 2195 to 2500 mm (86.4 to 98.4 in.) 4 E = B/5 *Use E = 530 or less when none of the E values shown above are used. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 For the Latest Information On the Internet: www.sti.com or www.omron.ca D15 F3SJ-A n Ordering The minimum components required for an F3SJ-A system are a emitter receiver set and a set of single or double-ended connector cables. See the table below for an overview of the versions available. The pages which follow provide specific part numbers and accessory descriptions. safety light curtains D Safety Light Curtain F3SJ-A Designator Protection Detection Beam Gap Operating RangeNo. of Beams Protective Height F3SJ-AP141 Finger 14 mm 9 mm 0.2 to 9 m (0.7 to 29.5 ft.) 26 to 180 245 to 1631 mm (9.6 to 64.2 in.) F3SJ-AP201 Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.) F3SJ-AP201 Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.) F3SJ-AP20-TS2 Hand 20 mm 15 mm 0.2 to 9 m (0.7 to 29.5 ft.) 16 to 100 245 to 1505 mm (9.6 to 59.3 in.) F3SJ-AP20-TS2 Hand 20 mm 15 mm 0.2 to 7 m (0.7 to 23.0 ft.) 110 to 166 1655 to 2495 mm (65.2 to 98.2 in.) F3SJ-AP301 Hand/arm 30 mm 25 mm 0.2 to 9 m (0.7 to 29.5 ft.) 10 to 65 245 to 1620 mm (9.6 to 63.8 in.) F3SJ-AP301 Hand/arm 30 mm 25 mm 0.2 to 7 m (0.7 to 23.0 ft.) 70 to 100 1745 to 2495 mm (68.7 to 98.2 in.) F3SJ-AP551 Leg/body 50 mm 50 mm 0.2 to 9 m (0.7 to 29.5 ft.) 6 to 33 270 to 1620 mm (10.6 to 63.8 in.) F3SJ-AP551 Leg/body 50 mm 50 mm 0. 2 to 7 m (0.7 to 23.0 ft.) 34 to 50 1670 to 2470 mm (65.7 to 97.2 in.) Notes: Connection cables are not included with the products and must be purchased separately as needed. 1 Models with S-mark certification have an "-S" at the end of the model number. S-mark certification is for equipment sold in South Korea. Example: F3SJ-A0245P14-S. 2 Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM "SD Manager" Support Software for F3SJ-A. Specific Model Numbers No. of Protective Model BeamsHeight (mm) F3SJ-A14 Series F3SJ-A0839P14 92 839 F3SJ-A0665P20 44 665 F3SJ-A2105P20 140 2105 F3SJ-A0245P14 26 245 F3SJ-A0875P14 96 875 F3SJ-A0695P20 46 695 F3SJ-A2255P20 150 2255 F3SJ-A0263P14 28 263 F3SJ-A0911P14 100 911 F3SJ-A0725P20 48 725 F3SJ-A2405P20 160 2405 F3SJ-A0281P14 30 281 F3SJ-A0983P14 108 983 F3SJ-A0755P20 50 755 F3SJ-A2495P20 166 2495 F3SJ-A0299P14 32 299 F3SJ-A1055P14 116 1055 F3SJ-A0785P20 52 785 F3SJ-A30 Series F3SJ-A0317P14 34 317 F3SJ-A1127P14 124 1127 F3SJ-A0815P20 54 815 F3SJ-A0245P30 10 245 F3SJ-A0335P14 36 335 F3SJ-A1199P14 132 1199 F3SJ-A0845P20 56 845 F3SJ-A0270P30 11 270 F3SJ-A0353P14 38 353 F3SJ-A1271P14 140 1271 F3SJ-A0875P20 58 875 F3SJ-A0295P30 12 295 F3SJ-A0371P14 40 371 F3SJ-A1343P14 148 1343 F3SJ-A0905P20 60 905 F3SJ-A0320P30 13 320 F3SJ-A0389P14 42 389 F3SJ-A1415P14 156 1415 F3SJ-A0935P20 62 935 F3SJ-A0345P30 14 345 F3SJ-A0407P14 44 407 F3SJ-A1487P14 164 1487 F3SJ-A0965P20 64 965 F3SJ-A0370P30 15 370 F3SJ-A0425P14 46 425 F3SJ-A1559P14 172 1559 F3SJ-A0995P20 66 995 F3SJ-A0395P30 16 395 F3SJ-A0443P14 48 443 F3SJ-A1631P14 180 1631 F3SJ-A1025P20 68 1025 F3SJ-A0420P30 17 420 F3SJ-A0461P14 50 461 F3SJ-A20, F3SJ-A20-TS* Series F3SJ-A1055P20 70 1055 F3SJ-A0445P30 18 445 F3SJ-A0479P14 52 479 F3SJ-A0245P20 16 245 F3SJ-A1085P20 72 1085 F3SJ-A0470P30 19 470 F3SJ-A0497P14 54 497 F3SJ-A0275P20 18 275 F3SJ-A1115P20 74 1115 F3SJ-A0495P30 20 495 F3SJ-A0515P14 56 515 F3SJ-A0305P20 20 305 F3SJ-A1145P20 76 1145 F3SJ-A0520P30 21 520 F3SJ-A0533P14 58 533 F3SJ-A0335P20 22 355 F3SJ-A1175P20 78 1175 F3SJ-A0545P30 22 545 F3SJ-A0551P14 60 551 F3SJ-A0365P20 24 365 F3SJ-A1205P20 80 1205 F3SJ-A0570P30 23 570 F3SJ-A0569P14 62 569 F3SJ-A0395P20 26 395 F3SJ-A1235P20 82 1235 F3SJ-A0595P30 24 595 F3SJ-A0587P14 64 587 F3SJ-A0425P20 28 425 F3SJ-A1265P20 84 1265 F3SJ-A0620P30 25 620 F3SJ-A0605P14 66 605 F3SJ-A0455P20 30 455 F3SJ-A1325P20 88 1325 F3SJ-A0645P30 26 645 F3SJ-A0623P14 68 623 F3SJ-A0485P20 32 485 F3SJ-A1385P20 92 1385 F3SJ-A0670P30 27 670 F3SJ-A0659P14 72 659 F3SJ-A0515P20 34 515 F3SJ-A1445P20 96 1445 F3SJ-A0695P30 28 695 F3SJ-A0695P14 76 695 F3SJ-A0545P20 36 545 F3SJ-A1505P20 100 1505 F3SJ-A0720P30 29 720 F3SJ-A0731P14 80 731 F3SJ-A0575P20 39 575 F3SJ-A1655P20 110 1655 F3SJ-A0767P14 84 767 F3SJ-A0605P20 40 605 F3SJ-A1805P20 120 1805 F3SJ-A0803P14 88 803 F3SJ-A0635P20 42 635 F3SJ-A1955P20 130 1955 Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D16 For the Latest Information On the Internet: www.sti.com or www.omron.ca A Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A F3SJ-A0745P30 30 745 F3SJ-A1245P30 50 1245 F3SJ-A0570P55 12 570 F3SJ-A1570P55 32 1570 F3SJ-A0770P30 31 770 F3SJ-A1270P30 51 1270 F3SJ-A0620P55 13 620 F3SJ-A1620P55 33 1620 F3SJ-A0795P30 32 795 F3SJ-A1295P30 52 1295 F3SJ-A0670P55 14 670 F3SJ-A1670P55 34 1670 F3SJ-A0820P30 33 820 F3SJ-A1395P30 56 1395 F3SJ-A0720P55 15 720 F3SJ-A1720P55 35 1720 F3SJ-A0845P30 34 845 F3SJ-A1495P30 60 1495 F3SJ-A0770P55 16 770 F3SJ-A1770P55 36 1770 F3SJ-A0870P30 35 870 F3SJ-A1620P30 65 1620 F3SJ-A0820P55 17 820 F3SJ-A1820P55 37 1820 F3SJ-A0895P30 36 895 F3SJ-A1745P30 70 1745 F3SJ-A0870P55 18 870 F3SJ-A1870P55 38 1870 F3SJ-A0920P30 37 920 F3SJ-A1870P30 75 1870 F3SJ-A0920P55 19 920 F3SJ-A1920P55 39 1920 F3SJ-A0945P30 38 945 F3SJ-A1995P30 80 1995 F3SJ-A0970P55 20 970 F3SJ-A1970P55 40 1970 F3SJ-A0970P30 39 970 F3SJ-A2120P30 85 2120 F3SJ-A1020P55 21 1020 F3SJ-A2020P55 41 2020 F3SJ-A0995P30 40 995 F3SJ-A2245P30 90 2245 F3SJ-A1070P55 22 1070 F3SJ-A2070P55 42 2070 F3SJ-A1020P30 41 1020 F3SJ-A2370P30 95 2370 F3SJ-A1120P55 23 1120 F3SJ-A2120P55 43 2120 F3SJ-A1045P30 42 1045 F3SJ-A2495P30 200 2495 F3SJ-A1170P55 24 1170 F3SJ-A2170P55 44 2170 F3SJ-A1070P30 43 1070 F3SJ-A55 Series F3SJ-A1220P55 25 1220 F3SJ-A2220P55 45 2220 F3SJ-A1095P30 44 1095 F3SJ-A0270P55 6 270 F3SJ-A1270P55 26 1270 F3SJ-A2270P55 46 2270 F3SJ-A1120P30 45 1120 F3SJ-A0320P55 7 320 F3SJ-A1320P55 27 1320 F3SJ-A2320P55 47 2320 F3SJ-A1145P30 46 1145 F3SJ-A0370P55 8 370 F3SJ-A1370P55 28 1370 F3SJ-A2370P55 48 2370 F3SJ-A1170P30 47 1170 F3SJ-A0420P55 9 420 F3SJ-A1420P55 29 1420 F3SJ-A2420P55 49 2420 F3SJ-A1195P30 48 1195 F3SJ-A0470P55 10 470 F3SJ-A1470P55 30 1470 F3SJ-A2470P55 50 2470 F3SJ-A1220P30 49 1220 F3SJ-A0520P55 11 520 F3SJ-A1520P55 31 1520 *The suffix "-TS" is attached to the model number of models with fixed auto reset. D safety light curtains Accessories Model Description Single-End Connector Cable (2 cables per set, for emitter and receiver) For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller F39-JC3A M12 connector (8-pin), 3 m (9.8 ft.) F39-JC7A M12 connector (8-pin), 7 m (23.0 ft.) F39-JC10A M12 connector (8-pin), 10 m (32.8 ft.) F39-JC15A M12 connector (8-pin), 15 m (49.2 ft.) F39-JC20A M12 connector (8-pin), 20 m (65.6 ft.) F39-JC7A Double-End Connector Cable (2 cables per set, for emitter and receiver) For connection with F3SP-B1P control unit, and for extension when series-connected. Note: To extend the cable length under series connection, use F39-JJR3W and F39-JCB in combination. F39-JCR5B M12 connector (8-pin), 0.5 m (1.6 ft.) F39-JC1B M12 connector (8-pin), 1 m (3.3 ft.) F39-JC3B M12 connector (8-pin), 3 m (9.8 ft.) F39-JC5B M12 connector (8-pin), 5 m (16.4 ft.) F39-JC7B M12 connector (8-pin), 7 m (23.0 ft.) F39-JC10B M12 connector (8-pin), 10 m (32.8 ft.) F39-JC15B M12 connector (8-pin), 15 m (49.2 ft.) F39-JC20B M12 connector (8-pin), 20 m (65.6 ft.) F39-JC15B Series Connection Cable (2 cables per set, for emitter and receiver) F39-JJR3W Series connection cable3 or when using water-resistant case4, 0.3 m (1.0 ft.) F39-JCB Extension cable, 0.5 to 15 m (1.6 to 49.2 ft.) F39-JCB F39-JJR3W To change series connection length in combination with F39-JJR3W F39-JJR06L Side-by-side series connection cable, 0.06 m (2.4 in.) Dedicated series connection cable with minimum length, used in place of the sensor's cable with connector F39-JJR15L Side-by-side series connection cable, 0.15 m (5.9 in.) Dedicated series connection cable with minimum length, used in place of the sensor's cable with connector Total cable length of series connection is 0.6 m to connect to connector cable of the main sensor unit. For series connection with minimum length, use the F39-JJR06L or F39-JJR15L. 4 When using the F39-EJ-L/D water-resistant case in series connection configurations, use the special series connection cables for the water-resistant case. 3 Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 F39-JJR06L F39-JJR15L For the Latest Information On the Internet: www.sti.com or www.omron.ca D17 F3SJ-A n Ordering (continued) Accessories (continued) Model Description Safety Controller F3SX-EL2 D Can connect 2 sets of F3SJ-As and emergency stop switch DC semiconductor safety output F3SX-E-L2L2 F3SX Can connect 4 sets of F3SJ-As and emergency stop switch safety light curtains DC semiconductor safety output F3SX-N-L2R Can connect 2 sets of F3SJ-As and emergency stop switch Relay output (2 N/O + 2 N/C) F3SX-N-L2L2R Can connect 4 sets of F3SJ-As and emergency stop switch Relay output (2 N/O + 2 N/C) Connection Cable for F3SX (F3SX to F39-CN5) F39-JC1T F3SX connection cable, 1 m (3.3 ft.) F39-JC3T F3SX connection cable, 3 m (9.8 ft.) F39-JC5T F3SX connection cable, 5 m (16.4 ft.) F39-JC7T F3SX connection cable, 7 m (23.0 ft.) F39-JC10T F3SX connection cable, 10 m (32.8 ft.) F39-JC15T F3SX connection cable, 15 m (49.2 ft.) F39-JC-10T Branch Connector for F3SX (F39-JCT to F39-JCB) F39-CN5 F39-CN5 Branch connector for F3SX F3SJ Emitter F3SJ Receiver Accessory connection example Wire color: Gray Wire color: Black Branch connector for safety light curtains F39-CN5 Gray Black Double-end connector cable: F39-JC@B-L (gray) Double-end connector cable F39-JC@B-D (black) Connection cable for F3SX F39-JC@T F3SX Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 D18 For the Latest Information On the Internet: www.sti.com or www.omron.ca A Go to the Engineering Guide For in-depth information on safety standards and use. F3SJ-A Accessories (continued) G7SA Model Description Control Unit F3SP-B1P Relay, 3 N/O + 1 N/C output, for connection with F3SJ-A, use an F39-JCB double-end G7S connector cable Force-Guided Relays G7SA-3A1B 4 contacts, 3 N/O + 1 N/C, Rated switch load: 250 VAC 6 A, 30 VDC 6 A G7S-4A2B-E 6 contacts, 4 N/O + 2 N/C, Rated switch load: 250 VAC 10 A, 30 VDC 10 A G7S-3A3B-E 6 contacts, 3 N/O + 3 N/O, Rated switch load: 250 VAC 10 A, 30 VDC 10 A F39-A01-PR-PAC Dedicated External Indicator Set (Can be connected to either an emitter or a receiver) F39-A01PR-PAC Indicator (red), mounting bracket (1 set), and dedicated connection cable (0.1 m) F39-A01PG-PAC Indicator (green), mounting bracket (1 set), and dedicated connection cable (0.1 m) F39-A01PY-PAC Indicator (yellow), mounting bracket (1 set), and dedicated connection cable (0.1 m) F39-JJ3N F39-HJ General External Indicator Cable Cable to connect top of the main unit and an off-the-shelf external indicator (2-wire), 3 m (9.8 ft.) Splatter Protection Cover F39-HJ For F3SJ-A series sensor, reduces operating range by 10%, includes two pieces for emitter and receiver Sensor Mounting Brackets (sold separately) F39-LJ1 Standard mounting bracket (for top/bottom), included with main unit, 2 for emitter and 2 for receiver (total of 4 per set) F39-LJ2 F39-LJ1 F39-LJ2 Flat side mounting bracket, Use these small-sized brackets when performing side mounting with standard mounting brackets so that they do not protrude from the detection surface, 2 for emitter and 2 for receiver (total of 4 per set) F39-LJ3 Free-location mounting bracket (also used as standard intermediate bracket), Use these brackets for mounting any place without using standard bracket, 1 set with 2 pieces Key Cap for Muting F39-CN6 F39-LJ3 F39-CN6 Cap attaches to the main unit to enable muting function, attach to either an emitter or a receiver, orange case Setting Tools 5 F39-GWUM "SD Manager" Setting Support Software for the F3SJ-A Accessories: SD Manager CD-ROM, F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual F39-MC21 Setting Console F39-GWUM Accessories: F39-CN1 Branch Connector, Connector Cap, 2 m Dedicated Cable, 0.3 m Dedicated Cable with Plug, Instruction Manual Water-Reistant Case (Set of 1 tube, packing, and dedicated connector cable) When using for both emitter and receiver, order two sets. F39-EJ-L Water-resistant case for emitter, includes gray cable for emitter F39-EJ-D Water-resistant case for receiver, includes black cable for receiver F39-EJ-R 6 Rear mounting brackets, top/bottom 1 each, total of 2 F39-EJ-S 6 Side mounting brackets, top/bottom 1 each, total of 2 F39-JJR3WE-L Series connection cable for emitter, purchase additionally for series connection when using the F39-MC21 water-resistant case F39-JJR3WE-D Series connection cable for receiver, purchase additionally for series connection when using the water-resistant case The setting tools described above can be connected only to F3SJ-A models with built-in software of Ver. 2 or later. Note that the setting tools cannot be used with products shipped prior to December 2005. The setting tools cannot be used for setting parameters on the F3SJ-A-TS series, but the monitoring function can be used. 6 Be sure to purchase brackets with the case to match the mounting direction (rear or side). 5 F39-EJ-R F39-EJ-L/D Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 F39-EJ-S For the Latest Information On the Internet: www.sti.com or www.omron.ca D19 safety light curtains 4 contacts, 2 N/O + 2 N/C, Rated switch load: 250 VAC 6 A, 30 VDC 6 A F39-JJ3N D F3SP-B1P G7SA-2A2B