Models CW120, CW121 Model CW240 AP240E Data Analysis Program AP240E Data Analysis Program 1 Bulletin CW-E Realization of Power & Power Quality Management using a CW240 CASE1 Get a view of energy consumption! It is essential to measure energy and manage consumption of each sector such as facility and production line for your energy saving activities and to minimize loss. CASE2 Contribute for improving productivity! Constantly analyze productivity by managing unit consumption. Managing voltage, current, electric power and power factor makes for good maintenance of production facility. Moreover, you can check operation management loss and enhance productivity. CASE3 Discover of electric power waste! Measure and collect data of electric power consumption by short period. The CW240 can figure out load of production process, and has the ability to check wasteful time and current flow of standby load current. 2 CASE4 Detect voltage fluctuation! When trouble occurs on supply side of electric power, instantaneous voltage drop can affect quality of produced goods at the factory. The CW240 is useful for collecting data such as voltage fluctuation to prevent such problems. Characteristics of CW240 Simultaneous measurement of instantaneous value, electric energy, demand, harmonics and voltage fluctuation. Simultaneous measurement of loads in 4 systems of up to 1P2W Simultaneous measurement of loads in 2 systems of up to 1P/3P3W Data saving interval can be set from 1 waveform (for instantaneous measurement) to 1 hour. Measure up to 50th order harmonics 4ch leakage current measurement using newly released clamp probe 96036 Long time data logging by using compact flash memory. Multi language for the display (English, German, French, Italian, Spanish, Korean and Chinese) 2ch analog input (Optional) Equipped with 4ch analog output (recorder output) AC adaptor for power supply. NiMH rechargeable battery and alkaline battery for backup Current input terminals With protection against H/L reverse connection of current clamp-on probes With protection against connection of voltage cables CW240 CW240 Voltage input terminals Protective cover External control I/O terminals CW120 RS-232C connector Analog I/O terminals (Optional) AP240E Card ejection button PC card slot 3 Battery holder Saves or prints the measured data. Starts/stops integration measurement. Makes a screen hard copy. Battery holder lock switch Returns to the TOP MENU. Switches the voltage/current range to another. Turns ON/OFF the backlight (locked when held down for a while). System Configuration Block Diagram MV series: Recorder CW240: Simultaneous measurement using two or more CW240 units External contact signal Current input (clamp) Voltage input External control I/O terminals START &STOP ENTER START ENTER &STOP DA output (4 channels) PC 510 series Illuminance meter RS-232 Analog input (2 channels) Printer CLAMP-ON POWER METER PC card AC adaptor Alkaline battery NiMH battery pack START TOP MENU LIGHT ESC ENTER &STOP RANGE 510 series Illuminance meter Product of Yokogawa Meters & Instruments Corporation A RANGE SAVE DISP COPY MV series: Recorder and JUXTA Product of Yokogawa Electric Corporation JUXTA Temperature converter Power Investigation Power Investigation Improves power Efficiency Through Detailed Data Coll Measurement of Instantaneous Value: For investigation of power consumption, maximum load factor and peak current The CW240 can be used to carry out investigation regarding renewal of electric equipment such as transformers in building, check load factors and demand factors, and to check current/voltage fluctuation at motor start-up. Allows switching data from one to another and saving data. (Example of screen display) Measurement elements : Voltage/current/electric power (active, reactive, apparent)/power factor/phase angle of each phase, average/minimum/maximum values of each measurement element. Data collection time : 1/2/5/10/15/30 seconds, 1/2/5/10/15/30/60 minutes One cycle (waveform), 100/200/500 ms (short time interval) Use of the 3-wattmeter method enables display of instantaneous value of each measurement element. Convenient functions 4 Investigation into Energy Saving at Factories and Buildings Solution Food processing plant Facility investigated : Pumps Purpose : To review the current power equipment, and replace it if necessary but with low investment cost CW240 Solution 1 : Calculation of the amount of used water based on power consumption since flow meters are expensive Solution 2 : Introduction of invert pump control Power measurement Power comparison before and after implementation of the solution before Clamp-on power meter after 14 12 Water supply pump Power (kw) 10 Water supply pump Water supply pump 8 AP240 Suitable for Data Analysis! 6 4 2 :0 0 12 :0 0 14 :0 0 16 :0 0 18 :0 0 20 :0 0 22 :0 0 00 10 00 8: 00 6: 00 4: 2: 0: 00 0 Time Energy saving & Reduce electricity bill Water supply pump ection. CW240 Power wer Quantity Measurement: For Power-Saving Diagnosis and Data Collection for ISO14001 The CW240 can measure and display the power quantity consumed up to the specified time (from the start of integration until the end). (Example of screen display) CW120 Measurement elements : Active power quantity, regenerative power quantity, reactive power quantity (leading/lagging) Data collection time : 1/2/5/10/15/30 seconds, 1/2/5/10/15/30/60 minutes The number of display digits and display units can be selected. Convenient functions Standard (Voltage/current range is selected according to the phase) Arbitrary (Decimal point position and display unit can be specified) Auto (Decimal point position and display unit are selected automatically according to the integration result) Demand Measurement: For Review and Investigation on Contract Demand (Example of screen display) AP240E Measurement elements : Maximum power demand required since the start of logging measurement and the time it occurs Active power, reactive power (lag), power factor Active power quantity (consumption, regeneration), reactive power quantity (lagging/leading) Normally, the demand time limit is set to 30 minutes in the contract with a power company. However, the CW240 allows you to set the desired demand time limit in units of seconds/minutes. Convenient functions Demand time limit setting : 1/2/5/10/15/30 seconds, 1/2/5/10/15/30/60 minutes 5 Demand Demand time limit : Length of time set to obtain the average power (normally 30 minutes) Demand power : Average power during the demand time limit Solution Energy Saving and Maintenance for Electric Equipment at Factories and Buildings Investigation at offices Lighting Cellulametal floor duct Air conditioning Lighting Office automation equipment Elevator CW240 solution (building) 1. For energy investigation/control for each application and floor 2. For simple investigation for each shop and tenant 3. Diagnosis of operational status of equipment such as elevator and air conditioner 4. Diagnosis regarding renewal of electric equipment Distribution board CW240 solution (factory) Personal computer Elevator Distribution board Distribution board Control panel Personal computer Investigation at production departments Power quantity Investigation of electric power consumption rate Production quantity Power factor 1. Diagnosis of operational status of equipment such as production equipment and air conditioner 2. For investigation of electric power consumption rate for each production line 3. For energy investigation/control for privately-owned electrical power facilities 4. For control of monthly target energy consumption Power Supply Quality Control Discovers Failures in Power Supply Lines. Harmonic Measurement In many cases, inverter power supplies are used to drive air-conditioners and compressors. These power supplies cause distortions in voltages and currents, leading to malfunctions and power loss. Therefore, investigation and control of influences on the main power supplies by harmonics is necessary. Harmonics for analysis : 1st to 50th Display data : List, bar graph (linear/log), vector (inflow/outflow judgment) Measurement elements : Level, content, phase angle (voltage/current/electric power of each harmonic), aggregate value (voltage, current, electric power, power factor), aggregate harmonic distortion factors (THD-F or THD-R) of voltage/current THD-F : Distortion factor for the fundamental wave, THD-R: Distortion factor for all rms values voltage/current Data collection time : 1/2/5/10/15/30/60 minutes (Example of graph display) (Example of list display) The harmonic whose data is required to be saved can be selected. Inflow/outflow of harmonics can be checked. Convenient functions THD-F Distortion factor for the fundamental wave, THD-R: Distortion factor for all rms values (Influences by harmonics) Category Power devices 6 : Inflow of harmonic Device Capacitor, reactor Influence type Overheat, burn, vibration, noise due to excessive current Transformer Overheat, noise, increase in core/copper loss Fuse, breaker Blow-out, malfunction due to excessive current Induction motor Periodic fluctuation of revolution speed, overheat, increase in loss Malfunction Electronic/electrical Protective relay household Electrical household Flickering, noise, malfunction, breakdown appliances appliances Fluorescent lamp, Burn of stabilizer/capacitor, flickering mercury-arc lamp Malfunction, out of control, breakdown Computer Electronics device Malfunction of automatic control part : Outflow of harmonic Explanation of vector diagram Vector length indicates the apparent power of each harmonic in proportion to that of the fundamental harmonic. The horizontal axis shows active power and the vertical axis indicates reactive power. They are shown in a logarithm. Frequencies shown are those of the measurement element actually measured. Improvement of Harmonic Measurement and Diagnosis Solution Printing plant Purpose: To investigate the cause for periodic breakdown of printing machine It may be caused by harmonics generated in the power lines. Measurement: Advantages obtained by using the CW240 th Compact and easy to carry Measurement of up to the 50 harmonic Long-term data collection Vector diagram display Result: Occurrence of harmonics in 5th and 7th was discovered! In addition, it became clear that harmonics are generated due to loads inside the factory. In perticular, the 5th harmonic causes adverse effects such as burn-out of the serial reactor in the capacitor used to improve the power factor. Before solution Time series for each harmonic for current 1 Content for each harmonic for current 1 Total harmonics distortion for current 1 Confirmation of inflow Discovery of the cause Countermeasure: Installation of transformer filter for 5th and 7th harmonics After solution Time series for each harmonic for current 1 Content for each harmonic for current 1 Total harmonics distortion for current 1 Effects of countermeasures: The contents of 5th and subsequent harmonics decreased drastically and the distortion ratio also dropped below 30%, resulting in elimination of breakdowns. 500kV transformer CW240 Waveform Measurement CW120 Measurement elements : Voltage of each phase, current of each phase Voltage and current of each phase Data saving format : Binary (can be converted to CSV format using a standard application program) The scale of the vertical axis can be changed from x1/3 to x20. Easy to understand waveform distortion. Voltage Fluctuation Measurement The CW240 detects dates/times of when fluctuations occur, fluctuation type, channels where they occur, rms values, and periods between start and end. The voltage threshold is set, and fluctuations exceeding the threshold are detected. Convenient functions Voltage swell (Voltage rise) Instantaneous power failure (Instantaneous stop of power supply) Normal period Measurement results It is possible to provide a voltage difference between start and end by setting a hysteresis. Failures in power supply lines Item Voltage dip (Sag, voltage drop) Fluctuation period Phenomenon A voltage drop occurs for a short time due to the occurrence of a large inrush current, for example, when a motor is started. Voltage increases instantaneously, for example, when lightning occurs or when a power line with a heavy load is turned ON/OFF. Power supply is stopped instantaneously or for a short/long time, for example, when a problem occurs in the power supply (suspension of power supply due to lightning, etc.) or due to the trip of a breaker caused by short circuits in the power supply, etc. Problem Decrease of power supply voltage may cause devices to stop or reset operations. Increase of power supply voltage may cause devices to stop or reset operations. Item Swe: Swell Dip: Dip Int: Instantaneous power failure 7 Occurrence date Instantaneous power failure may cause devices to stop or reset operations. Recently, various preventive measures have been taken for computers, thanks to widespread use of UPS (uninterruptible power source). Channel I: Start 0: End Detection period rms value Power Supply Quality Check at Various Places Solution Quality check for power supplies used in semiconductor manufacturing equipment in accordance with the SEMI guidelines Measure stability of the voltage of supplied power according to SEMI S2-0302 (Environmental, Health, and Safety Guideline for Semiconductor Manufacturing Equipment). If a sag (default: within 2%) occurs, the wafer is removed from the line for inspection so daily quality check for power supplies is necessary. SEMI: Semiconductor Equipment and Materials International SEMI guidelines are used at the time the contract is made, to evaluate the safety of semiconductor manufacturing equipment when exporting it from Japan to the USA. Voltage fluctuation image Result: Measurement results Normal period AP240E Normal period Measurement element : Voltage dip (voltage drop), voltage swell (voltage rise), instantaneous power failure lData saving : Detected based on the voltage rms value of one waveform. Up to 100 data sets can be saved. Fluctuation period Occurrence date/time of the sag can be reported so that semiconductor quality can be improved. Normal period Other: Advantages obtained by using the CW240 Compact and easy to carry Detects voltage fluctuations in each cycle. Instantaneous power failures and voltage fluctuations are monitored continuously, and the occurrence and recovery times are reported. Verification of instantaneous power failure preventive measures implemented in semiconductor manufacturing equipment Voltage level (100% as reference) 50% ~ Fall (rise) time 70% ~ 80% ~ 90% ~ 110% Within 0.2 sec. Within 0.5 sec. Within 10 sec. No limit ~ 120% Within 0.5 sec. Convenient functions Measures Loads in Four Systems Simultaneously. The CW240 enables simultaneous measurement of loads in four systems in the case of the single-phase 2-wire system, and in two systems in the case of the single/three-phase 3-wire system (common to voltage). Current clamp probe/range can be set for each system. This allows measurement according to the current flowing in each load. (example) 1 Power supply N N 8 U1 CW240 side CH1 CH2 CH3 Load 1 200A Load 2 100A Load 3 10A Load 4 2A CH4 Example of single-phase 2-wire system Reduces Operation Errors at Work Site. Wiring check function Prior to start of measurement, the CW240 checks whether wiring is correct. Wiring errors, reverse connection of current clamps, and phases to be checked can be displayed in a vector diagram. Checking the phases displayed in a vector diagram OK/NG judgment Measured values Setting check function Settings made for data saving can be checked in the screen. This prevents data acquisition errors that may occur due to mistakes in voltage range setting, current clamp selection or data save item selection. Phase/range etc. Data save item Measurement start/end To change the settings, press this button to display the setting screen. CW240 Saving a Large Amount of Data Use of an external memory card (compact flash) makes it possible to save a large amount of data. A memory card (*1) of up to 2GB can be used, and the data is saved in CSV format. (*2) In addition, the CW240 has a 1MB internal memory. Storage period when PC card (512MB) and internal memory (1MB) are used When storing all items of measured data, measured power quantity/demand data, and measured voltage fluctuation data Wiring 1P2W 1P3W 1P3W31 4 systems 2 systems 3P3W21 2 systems 3P3W31, 3P4W 3P4W41 3P3W +1P3W Number of storable data items Recording medium PC card (512MB) Internal memory (1MB) 168 196 114 208 138 142 216 1s 9 hrs 8 hrs 14 hrs 8 hrs 12 hrs 12 hrs 7 hrs 1min 24 days 21 days 37 days 20 days 30 days 30 days 19 days 60min 1471 days 1304 days 2223 days 1232 days 1852 days 1802 days 1188 days 1s 8 min 7 min 12 min 7 min 10 min 10 min 6 min 1min 8 hrs 7 hrs 12 hrs 7 hrs 10 hrs 10 hrs 6 hrs 60min 21 days 18 days 32 days 17 days 26 days 26 days 17 days Interval time CW120 *1: Memory cards purchased from Yokogawa should be used. *2: Data shorter than one second is saved in binary format. Screen copies can be made in bitmap format. Voltage fluctuation data is saved in text format. When storing all items of measured data, measured power quantity/demand data, all items of measured harmonics data, waveform data and measured voltage fluctuation data Wiring 1P2W 1P3W 1P3W31 4 systems 2 systems 3P3W21 2 systems 3P3W31, 3P4W 3P4W41 3P3W +1P3W Number of storable data items 5052 3758 6888 4390 5002 7504 Interval time PC card (512MB) 1min 17 hrs 19 hrs 26 hrs 14 hrs 22 hrs 19 hrs 13 hrs 60min 44 days 49 days 65 days 35 days 56 days 49 days 32 days 1min 12 min 13 min 19 min 8 min 16 min 13 min 7 min 60min 12 min 13 hrs 19 hrs 8 hrs 16 hrs 13 hrs 7 hrs Internal memory (1MB) AP240E 5642 Recording medium Leakage Current Measurement - External magnetic field effect is 0.002A or less, at 400A/m - 1R Yokogawa's proprietary technology has achieved a magnetic field impact amount of 30 ppm even in adjacent power lines. (At 100A) Use of the 2A current clamp probe (96036) enables measurements with 200.0 mA range. 2S Power supply Load 3T N 9 Current clamp probe 96036 N U1 CW240 side U2 U3 CH1 CH2 CH3 CH4 Three-phase 4-wire 4-current Analog Input/Output - Besides power data - Voltage, current, power etc. Analog data such as temperature and illuminance data can be saved simultaneously with power data by using the analog input function (2 channels). The available input ranges are 100 mV/1 V/5 V. In addition, the analog output function (4 channels) acquires data to an external recorder, allowing data duplexing. Output is 1 VDC. (The analog input/output function is optional.) Temperature, illuminance etc. Analog output 2 channels Digital illuminance meter 51001 Other Convenient Functions Power supply backup Besides the AC adapter, it is possible to use a NiMH battery pack (94004) or alkaline batteries (six AA batteries). The CW240 will continue to operate even if supply of power is interrupted. Multi-lingual support The CW240 supports Japanese, English, German, French, Spanish and Italian (available in the near future). Manual data saving Screen hard copy Zoom function The data for the selected items can be saved or printed using the SAVE key. However, it cannot be saved during integrating measurement (and during standby). The currently displayed screen can be saved or printed using the DISP COPY key. Files are saved in bitmap format. The measured data for the selected five items can be zoomed in. The items to be displayed can be selected from instantaneous value and measured power quantity data. Specifications Inputs Item Input type Voltage Resistive potential division Clamp detection Varies with the clamp and range used. 96036 (2A) 200.0/500.0mA/1.000/2.000A 96033 (50A) 5.000/10.00/20.00/50.00 A 96030 (200A) 20.00/50.00/100.0/200.0 A 96031 (500A) 50.00/100.0/200.0/500.0 A 96032 (1000A) 200.0/500.0 A/1.000 kA 96034 (3000A range) 300.0/750.0 A/1.500/3.000 kA (2000A range) 200.0/500.0 A/1.000/2.000 kA (1000A range) 100.0/200.0/500.0 A/1.000 kA 96035 (3000A range) 300.0/750.0 A/1.500/3.000 kA (300A range) 30.00/75.00/150.0/300.0 A 150.0 V Rated value (range) Equations Active power, reactive power, apparent power, power factor and phase angle are measured for each phase. The average, maximum and minimum values of those obtained during integrating measurement are calculated. Current 300.0 V 600.0 V 1000 V T T T T Voltage rms 1 u (t)2dt = 1 u (t)2 Umrms = T m m T 0 t=0 Current rms 1 i (t)2dt = 1 i (t)2 Imrms = T m m T 0 t=0 T T 0 t=0 Active power Pm = T1 {um(t) im(t)}dt = T1 {um(t)im(t)} Reactive power 1 Phase to be measured Maximum allowed input (continuous) A/D converter Approx. 1.3M Equations for Each Phase Wiring Approx. 100K (CW240 main unit) 1000 Vrms T 1 {u (t)i (t + T )}dt = 1 {u (t)i (t + T )} Qm = T m m m m T 4 4 0 t=0 Single-phase 2-wire, single-phase 3-wire, single-phase 3-wire 3-current (current in neutral line), three-phase 3-wire 2-current (2-power meter method), Three-phase 3-wire 3current (3-power meter method), three-phase 4-wire, three-phase 4-wire 4-current (current in neutral line), Scott connection (three-phase 3-wire + single-phase 3-wire) Number of systems With the same voltage Single-phase 2-wire: 4 systems, single-phase 3-wire: 2 systems, three-phase 3-wire 2to be measured current: 2 systems Input resistance 96036 (2A) 96033 (50A) 96030 (200A) 96031 (500A) 96032 (1000A) 96034 (3000A range) 20Arms 130Arms 250Arms 625Arms 700Arms 2400 Arms (3600 Arms for 10 minutes) (2,000A range) (1000A range) 96035 (3000A range) (300A range) 2400Arms 1200 Arms 3600 Arms 360 Arms Equation Symbol Single-phase 3-wire -- Uave (U1 + U2)/2 Average current -- Iave (1 + I2)/2 Active power -- P P1 + P2 P1 + P3 Q Q1 + Q2 S - P S1 + S2 3 (S1 + S3) 2 Reactive power 2 (*3) Q= S Apparent power Power factor Item 45 to 65Hz (Measurement element is selected from U1, U2 and U3) Accuracy 0.1%rng. Power factor influence -- Reactive factor influence -- 96030, 96031, 96033, 96036 0.6%rdg.0.4%rng. 96032, 96034, 96035 1.0%rdg.0.8%rng. 96030 1.0%rng (45 to 65Hz, power factor =0.5) Other than 96030 2.0%rng (45 to 65Hz, power factor =0.5) 96030 1.0%rng. (45 to 65Hz, reactive factor =0.5) Other than 96030 2.0%rng (45 to 65Hz, reactive factor =0.5) Active input range 5 to 110% of each range (Max. 100% in the case of 1000V range) Display range Voltage / current: 0.4 to 130% of each range (Zero suppression when below 0.4% of the range) Power (active, reactive, apparent): 0 to 130% of each range (Zero suppression when below 0.17% of the range rating). Harmonic level: 0 to 130% of each range Frequency: 40 to 70Hz Temperature coefficient 0.03%rng/C Display updating interval Approx. 0.5 seconds rdg: Reading S S = UI 2 P1 + P2 + P3 *4 Q1 + Q2 + Q3 *4 2 S1 + S2 + S3 *4 PF PF = P S When the reactive power meter method is used PF PF = -- PA PA = cos-1PF P P2 + Q2 *1: Line voltage is measured in the case of 3-phase 3-wire system, and phase voltage in the case of 3-phase 4-wire system. *2: I2 for three-phase 3-wire system (2-power meter method) is calculated by vector operation. *3: This equation is applicable when the reactive power meter method is not used. Even in this case, the value is multiplied by the polarity of Q for each phase calculated by the reactive power meter method. *4: In the case of three-phase 3-wire system, the phase voltage from the virtual neutral point is used to calculate each phase power. *5: Multiplied by the polarity of Q for each phase calculated by the reactive power meter method. *6: In the case of distorted waves and unbalanced inputs, there may be differences from other instruments that employ different measurement principles. P1, P3, Q1, Q3, S1, S3, PF1 and PF3 are obtained during calculations carried out by the 2-power meter method, and do not exist as physical values. Rated input: 3 (however, 1.8 when 1000V range is used) 0.2%rdg. --P 2 (I1 + I2 + I3)/3 *2 In the case of distorted waves, there may be differences from other instruments that employ different measurement principles. Current / Active power / Reactive power (reactive power meter method is used) Frequency range Crest factor 10 Voltage Digital sampling 2 (U1 + U2 + U3)/3 *1 When the reactive power meter method is not used (*5) Phase angle (*5) Measurement Functions Three-phase Three-phase Three-phase 3-wire 3-wire 4-wire 2-current *6 3-current Measurement Items Average voltage Voltage/current input simultaneous conversion, PLL synchronized 128 samples/period, 16-bit resolution Method u(t): Voltage input signal i(t) : Current input signal T : One cycle of input signal m : Each phase When the reactive power meter method is used T 0.05%rng/C rng: Range Range Configuration for Active Power For single-phase 2-wire system (X2 for single/three-phase 3-wire system, X3 for three-phase 4-wire system) When 96030 / 96031/ 96032 / 96033/ 96036 is used Current range 96032(1000A) 96031(500A) Voltage range 96030(200A) 96036(2A) 1.000 A 96033(50A) 200.0 mA 500.0 mA 150.0 V 30.00 W 75.00 W 150.0 W 300.0 W 2.000 A 5.000 A 10.00 A 20.00 A 50.00 A 100.0 A 200.0 A 500.0 A 1.000 kA 750.0 W 1.500 kW 3.000 kW 7.500 kW 15.00 kW 30.00 kW 75.00 kW 150.0 kW 300.0 V 60.00 W 150.0 W 300.0 W 600.0 W 1.500 kW 3.000 kW 6.000 kW 15.00 kW 30.00 kW 60.00 kW 150.0 kW 300.0 kW 600.0 V 120.0 W 300.0 W 600.0 W 1.200 kW 3.000 kW 6.000 kW 12.00 kW 30.00 kW 60.00 kW 120.0 kW 300.0 kW 600.0 kW 1.000 kV 200.0 W 500.0 W 1.000 kW 2.000 kW 5.000 kW 10.00 kW 20.00 kW 50.00 kW 100.0 kW 200.0 kW 500.0 kW 1.000 MW When 96034 / 96035 is used Current range 96034_3(3000A) 96034_2(2000A) 96034_1(1000A) Voltage range 96035_1(3000A) 96035_2(300A) 30.00 A 75.00 A 150.0 A 300.0 A 100.0 A 200.0 A 500.0 A 1.000 kA 2.000 kA 300.0 A 750.0 A 1.500 kA 3.000 kA 150.0 V 4.500 kW 11.25 kW 22.50 kW 45.00 kW 15.00 kW 30.00 kW 75.00 kW 150.0 kW 300.0 kW 45.00 kW 112.5 kW 225.0 kW 450.0 kW 300.0 V 9.000 kW 22.50 kW 45.0 kW 90.00 kW 30.00 kW 60.00 kW 150.0 kW 300.0 kW 600.0 kW 90.00 kW 225.0 kW 450.0 kW 900.0 kW 600.0 V 18.00 kW 45.00 kW 90.00 kW 180.0 kW 60.00 kW 120.0 kW 300.0 kW 600.0 kW 1.200 MW 180.0 kW 450.0 kW 900.0 kW 1.800 MW 1.000kV 30.00 kW 75.00 kW 150.0 kW 300.0 kW 100.0 kW 200.0 kW 500.0 kW 1.000 MW 2.000 MW 300.0 kW 750.0 kW 1.500 MW 3.000 MW Frequency Measurement Function Measurement input Voltage input Selectable from U1, U2 and U3 Measurement frequency range 45 to 65 Hz Display range 40.00 to 70.00 Hz Accuracy 0.1%rdg. 1dgt For 10% to 130% sine wave input of voltage range Low-pass filter function Cutoff frequency: Approx. 300 Hz OFF/ON selectable Harmonic Measurement Function Method PLL synchronization Measurement frequency range Fundamental wave frequency 45 to 65 Hz Harmonics for analysis 1st to 50th Window width 1 cycle Window type Rectangular Analysis data quantity 128 points Analysis rate 1 sample/16 cycles Analysis items Harmonic level: Level of each harmonic of voltage, current and power Relative harmonic content: Content of each harmonic of voltage, current and power Harmonic phase angle: Phase angle of each harmonic of voltage, current and power For voltage and current, the phase angle of the fundamental wave or that of U1 can be selected as the reference. Total value: Total value of all the harmonics up to the 50th harmonic of voltage, current, power and power factor Total harmonic distortion rate: Voltage / current (THD-F or THD-R) Accuracy Harmonic level 1st to 20th: 1.5%rdg. 1.5%rng 21st to 30th: 2.0%rdg. 1.5%rng 31st to 50th: 3.0%rdg. 1.5%rng Relative harmonic content: Value calculated from harmonic level 2dgt Harmonic phase angle The accuracy is guaranteed if both voltage and current levels for each harmonic are 5% of the range or higher. 1st to 20th: 5 20th to 50th: (0.3 X k+1) k: Order The accuracy for current in relation to the fundamental wave is not specified. Display data List, bar graph (linear/log), vector Waveform Measurement Function Measurement elements Selectable from voltage/current waveform of same phase, all voltage waveforms, and all current waveforms. Magnification change x1/3 to x 20 in relation to the rating Display data 1 waveform Voltage Fluctuation Measurement Function Measurement elements Voltage dip, voltage swell, instantaneous power failure Measurement method Detected based on voltage rms of one waveform. Threshold/hysteresis Can be set in percentage in relation to the reference voltage. Accuracy Same as voltage rms accuracy Detection period Time length during which the threshold is exceeded Display data Occurrence date (year, month, day), voltage rms, detection period Number of events 100 Display Function Display Backlight Contrast Display digits Language Display average function Display hold 5.7-inch STN monochrome LCD display (320 dots x 240 dots) with backlight OFF/ON and auto OFF selectable Automatically adjusted according to the ambient temperature / Settable in 8 steps. Items other than power quantity: 4 digits Power quantity: 6 digits English, Japanese, German, French, Spanish, Italian, Korean and Chinese Moving average (Averaging count: selectable from 2, 5, 10 and 20) Hold / cancel Save/Print Function Data can be saved/printed manually or automatically. Storage media Internal memory: 1MB or PC card Printing Dedicated printer (via RS-232) Save/print data Measured data, voltage variation data, waveform data, screen data, setting data Saving format Measured data: CSV format (Binary format if short-time interval is set) Voltage variation data: Text format Waveform data: Binary format Screen data: BMP format (bitmap) Setting data: Text format Save/print interval Standard interval: 1/2/5/10/15/30 seconds, 1/2/5/10/15/30/60 minutes It is not possible to output/print measured harmonic and waveform data if the interval is shorter than 30 seconds. Data storage time display Unoccupied capacity in the storage destination Data save items, calculated based on the interval time. File operation Rename Deletion Format Data copy Setting file File names in the internal memory and PC card can be changed. File names in the internal memory and PC card can be deleted. PC card and internal memory and can be initialized Files in the internal memory can be copied to the PC card. Setting file can be read, written, deleted and renamed. Communication Function Electrical specifications Synchronization system Baud rates Connector EIA RS-232 Asynchronous communication 1200/2400/9600/19200/38400 bps D-sub 9-pin PC card interface Slot Compatible card Data format Recording contents PC card slot TYPE II (x1) ATA flash memory card MS-DOS format Measured data, voltage fluctuation data, waveform data, screen data, setting data External control I/O terminals Used to control start/end of integrating measurement. Control input TTL level or contact Control output TTL level Analog Input and DA Output Functions (Optional) DA output Output voltage 1VDC of the rated value for each range Power quantity depends on the output rate. X1, X10 and X100 can be set for harmonics. Frequency: 0.4 to 0.7V / 40 to 70 Hz Number of output channels 4 channels Output data (Four items can be selected) Instantaneous value Voltage, current, average voltage, average current, active power, reactive power, apparent power, power factor, phase angle, frequency Power quantity Active power quantity (consumption, regeneration), reactive power quantity (lagging/leading) Harmonic Accuracy Resolution Updating interval Temperature coefficient Output resistance Power quantity output route Analog input Input ranges Number of inputs Accuracy Resolution Sampling rate Input resistance Level, content, phase angle, total value, THD (THD-F or THD-R) (Measurement accuracy + 0.2%f.s.) Polarity + 11 bits Other than harmonic measurement: 1 cycle of input signal Harmonic measurement: 16 cycles of input signal 0.02%f.s./C or less 225% Selectable from 1V/1kWh, 1V/5kWh, 1V/10kWh, 1V/50kWh, 1V/ 100kWh, 1V/500kWh and 1V/1000kWh. 100mV/1V/5VDC 2 channels 0.5% f.s Polarity + 11 bits Approx. 20ms Approx. 100k Clock Function Automatic calendar, automatic leap-year setting, 24-hour system Real-time accuracy 20 ppm (Typ., 23C) Wiring Check Function Verification of validity of measurement of voltage/current input value, voltage/current phase difference, voltage-to-voltage phase difference, current-to-current phase difference and frequency Verification of single-phase load (in the case of Scott connection) Wiring diagram, vector diagram display Setting Check Window Used to check data save items and start/end for integrating measurement. Other functions VT ratio/CT ratio setting, ID number setting, NiMH (nickel hydride battery) charge, remaining battery voltage display, beep sound (key operation), key lock, system reset General specifications Location for use: Storage temperature and humidity ranges Operating temperature and humidity ranges Insulating resistance Indoor, at an altitude of 2000 meters or less -20 to 60C, 90%RH (no condensation) 5 to 40C, 5 to 80%RH (no condensation) 500 VDC, 50M or greater Between voltage input terminals and case Between voltage input terminals and current input terminals / DC power terminals / external interface terminals Insulating withstand voltage (50/60Hz, for one minute) 5.55 kVAC rms for one minute (Sensed current: 1mA) Between voltage input terminals and case 3.32 kVAC rms for one minute (Sensed current: 1mA) Between voltage input terminals and current input terminals / DC power terminals / external interface terminals Power supply AC adapter (standard accessory), 100 to 240 VAC, 50/60Hz Backup battery (for power failure) Six AA size alkaline batteries (standard accessory) One NiMH battery pack (optional) Maximum rated power consumption Main unit: Approx. 10W (normal operation), approx. 20W (during charging of NiMH battery pack) AC adaptor: Approx. 30VA (normal operation), approx. 60VA (during charging of NiMH battery pack) External dimensions Approx. 206 (W) 184 (H) 65 (D) mm (excluding projecting parts) Weight Approx. 1.2 kg (without batteries) Accuracy guarantee conditions Warm-up time 30 minutes or more (within active input range, sine wave input, power factor=1, PLL synchronization) Accuracy guarantee temperature and humidity ranges 235C, 30 to 75%RH Accuracy guarantee frequency range 45 to 65Hz Accuracy warranty period 1 year AP240E Demand Measurement Function Measurement elements Active power (consumption), reactive power (lagging), power factor: Demand value within the interval time Active power quantity (consumption, regeneration), reactive power quantity (lagging), leading: Power quantity within the interval time Maximum demand (consumption power demand) required since the start of integrating measurement and the time it occurs Measurement accuracy Measurement accuracy of active power and reactive power 1dgt (When STANDARD is selected as the standard number of display digits) 0.1/0.2/0.5 seconds for each waveform Only instantaneous values can be input. CW120 Power Quantity Measurement Function Measurement elements Active power quantity, regenerative power quantity, reactive power quantity (lead/lag) Measurement accuracy Measurement accuracy of active power and reactive power 1dgt (When STANDARD is selected for display digits) Measurement range Active power quantity Consumption 0.00000 mWh to 999999 GWh Regeneration -0.00000 mWh to -999999 GWh Reactive power quantity Lagging 0.00000 mvarh to 999999 GVarh Leading -0.00000 mvarh to -999999 GVarh Display digits setting function Selectable from automatic setting by rated power, minimum resolution setting, and minimum resolution shift by integrated value. Integration time accuracy 20 ppm (Typ., 23C) Short-time interval: CW240 Specifications of Each Function 11 Model CW120 Clamp-on Power Meter CW120 Maintenance and long term monitoring of electrical equipment and electrical system. Current input (clamp) Voltage input External I/O controller port (integration start/stop signal: function to start/stop multiple units simultaneously) RS-232 connector (8-pin) 12 100-240VAC Power connection PC card slot (flash ATA memory) Power switch Model CW121- -1 Easy-to-recognize function icons Low-cost tools to support your energy conservation efforts CW240 As energy conservation becomes increasingly important, we are pleased to present low-cost clamp-on power meters designed to meet user needs for simple tools capable of measuring power values and instantaneous values. Useful features for energy conservation and power wer measurement Periodically save data as often as once a second Check equipment operating conditions Simultaneous measurement of multiple facilities Multiple CW120 Series units can start and stop integration simultaneously through externally controlled I/O. Works even with small electric energy values Easily change the decimal position (the number of digits following the decimal point) and display unit (Wh, kWh, MWh, GWh) on the electric energy display. Details for Models CW120/CW121 CW120/CW121 Items Input system Single-phase 2-wire to 3-phase 4-wire Instant mode (Up to 3 phase 3 wire for CW120) Electric Energy mode Available Display Screen Segmented LCD with backlight Communication Interface RS232 or RS485 Protocol MODBUS, PC-link, Power-Monitor, Proprietary Monitoring by AP240E Available Measurement Mode Power supply AP240E The CW120 Series has an instantaneous value filing function (enabling multiple data records to be saved in a single file when multiple measurements are taken) which is useful for determining equipment operating conditions. This function helps ensure that measurement operations are correct. CW120 Data can be saved as low as 1-second interval. This capability allows the CW120 Series to respond quickly to load fluctuations and measure transient responses in equipment. Wiring error check function 13 100 to 240V AC, Supply the power from input. Size (WHD) 11716151mm Weight 600g Load measurements on multiple systems 1o2W Three current systems (example) 2 Load 3 side 1 (Facility 3) Power supply side In addition to support for a variety of connection types, The CW120 Series can simultaneously measure the loads* (facilities, equipment) on multiple systems sharing a common power supply. CW120 (three-phase 3-wire model): 1o2W2 CW121 (three-phase 4-wire model): 1o2W2, 3 Load 2 side (Facility 2) Load 1 side (Facility 1) Low-cost tools to support your energy conservation efforts Compact design The CW120 Series is compact in size (11716151mm (WHD)), making it ideal for installation in cubicles and inside distribution panels. Installation is even easier with the magnetic case (93023). Although the CW120 Series is small, it has a large backlit LCD. A new addition to the clamp lineup is a small-diameter current clamp (model 96033, capable of measurements in the range of 5-50 A) for measurements in tight spots and locations where many wires are jumbled together. Current clamp (96033) Approximately 70 mm o18 mm Magnetic case (93023) 14 Measurements The CW120 Series can be used for voltage measurements up to 495 V. A variety of connection types are supported, from single-phase 2-wire to three-phase 4-wire (CW120: three-phase 3-wire model; CW121: three-phase 4-wire model). Continuous measurement integration (accurate measurements can be obtained even if there are large load fluctuations) Plus/minus signs are shown for reactive power and power factor. The data saving interval can be set in the range of one second to one hour. Parameters setting tool (name: Toolbox) The setting software allows you to set CW120 Series measurement conditions through a PC and save measurement data on a PC when the unit is connected to the PC through RS-232 or RS-485 port. Measurement conditions setting function This function makes it easy to set basic functions needed for measurement, such as start/stop time and date, wiring method, clamp type, voltage, and current range etc. File transfer function The data file stored in CF pack can be transfered to PC. Microsoft Excel can read transferred data file. Setting screen * Toolbox is included as a standard feature (on two floppy disks). RS-232 comm. cable Microsoft, Windows, and Excel are trademarks or registered trademarks of Microsoft Corporation, the United States. File transfer screen Advanced data management and communication CW240 Data management and communication 1 You can connect CW120 to a PC through dedicated RS-232 cable. 2 A printer (sold separately) can be connected through RS-232 cable to print measurement data. 3 If you have a media reader connected to your PC or card slot in notebook PC, measurement data and settings can be uploaded directly to a PC from CF* pack. CF pack 3 CW120 Comm. Cable Model 91011 1 Memory Card Memory capacity Interval Time 10sec Interval Time 1sec Wiring Method 97034 256MB Approx. 103days Approx. 70hours 3system 1o2W 97035 512MB Approx. 206days Approx. 140hours 3system 1o2W 97037 2GB Approx. 2years Approx. 560hours 3system 1o2W Media reader PC 2 Printer Cable Model 91010 Printer Model 97010 AP240E * Compact Flash cards with memory capacity up to 2 GB may be used. Network Communication CW120 In addition to proprietary communication also supports, MODBUS, PC-link and Power Monitor protocols. PC-link is a protocol for Yokogawa's Temperature controllers and PLCs. Power Monitor protocol is a protocol for Yokogawa's Power Monitors. (PR201) Data Management by DAQLOGGER* PC 15 Internet Model MV Model MV Yokogawa's Recorder WEB function: Model MV100/200 can be monitored by Internet Browser on PC. E-mail Alarm function: The alarms from Model MV100/200 can be sent to PC as an Email. FTP function: Model MV100/200 can send gathering data as a file to PC by using FTP function. RS485-MODBUS protocol * DAQLOGGER is Yokogawa's communication software for Windows Remote monitoring The RS-485 allows multiple use to be connected for remote monitoring. PC Monitoring Software * RS-485/RS-232 converter is required to connect the CW120/CW121-m-2 (RS485 communication spec) to the RS-232 port on your PC. Recommended brand and model: Yokogawa's RS-232/RS-485 Converter Model ML2. RS-232 Converter RS-485 Max 31 units, 1.2km Specifications Equations Inputs Parameter Input type Voltage (V) Resistive potential division Current (A) Clamp detection Clamp 96033: 5/10/20/50 A Rated value (range) Clamp 96030: 20/50/100/200 A 150/300/450 V Clamp 96032: 200/500/1000 A Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire CW121 Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire Input CW120 Approximately 1.5 M resistance CW121 Approximately 1.3 M *Current rms Arms= *Active power P= Clamp 96033: 130 Arms input Clamp 96030: 250 Arms 495 Vrms Clamp 96031: 625 Arms Clamp 96032: 1000 Arms Voltage/current input simultaneous conversion, 12-bit resolution 1 T 1 T T 1 T T 0 0 dt = 1 T T t=0 dt = 1 T T t=0 1 T i 0 T dt = T t=0 Single-phase 3-wire, three-phase 3-wire Three-phase 4-wire Approximately 100 k Maximum allowed A/D converter Vrms= Clamp 96031: 50/100/200/500 A CW120 Wiring *Voltage rms P = P1 + P2 P = P1 + P2 + P3 (t), i(t): Input signals T: One period for input signal *Reactive power and power factor Apparent power Reactive power (Note 2) Power factor (Note 2) Single-phase 2-wire Single-phase 3-wire Measurement Input functions Current/active power Digital sampling Frequency range 45-65 Hz (reciprocal system), detected from V1 Crest factor 150/300 V range Rated input: 2 450 V range Rated input: 1.56 Active input range (Note 3) Computation range Display resolution Rated input: 3 10-110% of each range All ranges 1.5 V 0.4% of each range 130% of each range, except 110% for 450 V range 130% of each range 0.05% rng/C 0.07% rng/C (including clamp) Display updating interval Approximately one second Lower limit range Three-phase 3-wire Three-phase 4-wire Upper limit Temperature coefficient Display 16 Voltage Parameter Method Rated value depends on V and A ranges. Rated value depends on V and A ranges. Internal computation only; data not displayed or saved. Same as for active power. Note 1: In the case of distorted waves, there may be differences from other measuring instruments that are based on different measurement principles. Note 2: The polarity of each phase determined by the reactive power meter method is multiplied and the polarity is displayed. Note 3: In the case of three-phase 3-wire and unbalanced inputs, there may be differences from other measuring instruments that are based on different measurement principles, or wiring. Instantaneous Value Measurement Electric Energy Measurement *Measurement parameters: *Measured parameters: Active electric energy, regenerative electric energy (regenerative electric energy is not displayed on the screen; it is merely saved) *Measurement accuracy: Active power measurement accuracy 1 dgt (with standard settings) *Integration function settings Start/stop settings: Manual, timer, external trigger (control) Output intervals: 1/2/5/10/15/30 seconds; 1/2/5/10/15/30 minutes; 1 hour *Displayed digits: This is set automatically based on the rated power, and the minimum resolution can be set Voltage rms (V), current rms (A), active power (W), frequency (Hz) *Measurement accuracy (at power factor 1, including clamp) Voltage: (0.3% rdg + 0.2% rng) Current/active power: (0.8% rdg + 0.4% rng) when using clamps 96030, 96031, and 96033 (1.2% rdg + 0.8% rng) when using clamp 96032 Frequency: (0.1% rdg + 1% dgt) *Computation parameters: Reactive power (Var), power factor *Computation accuracy: (value calculated from measurement) 1 dgt *Power factor influence: 1.0% rng coso = 0.5 (relative to power factor 1) when using clamp 96030 2.0% rng coso = 0.5 (relative to power factor 1) when using clamps 96031, 96032, and 96033 *Reactive factor influence: 1.0% rng sino = 0.5 (relative to reactive factor 1) when using clamp 96030 2.0% rng sino = 0.5 (relative to reactive factor 1) when using clamps 96031, 96032, and 9603 Saving items *Saving items: Voltage, current, active power, reactive power, power factor, frequency, active electric energy, regenerative electric energy Display Functions *Display screen: Backlit segmented LCD *Maximum number of displayed digits Electric energy: 6 digits Other parameters: 4 digits *Range makeup: (rated values) Clamp 96032 Clamp 96031 Clamp 96030 Clamp 96033 Voltage 150.0V 300.0V 450.0V Wiring 5.000 A 10.00 A 20.00 A 50.00 A 100.0 A 200.0 A 500.0 A 1.000 kA 1o2W 750.0 W 1.500 kW 3.000 kW 7.500 kW 15.00 kW 30.00 kW 75.00 kW 150.0 kW 1o3W 1.500 kW 3.000 kW 6.000 kW 15.00 kW 30.00 kW 60.00 kW 150.0 kW 300.0 kW 3o3W 1.500 kW 3.000 kW 6.000 kW 15.00 kW 30.00 kW 60.00 kW 150.0 kW 300.0 kW 3o4W 2.250 kW 4.500 kW 9.000 kW 22.50 kW 45.00 kW 90.00 kW 225.0 kW 450.0 kW 1o2W 1.500 kW 3.000 kW 6.000 kW 15.00 kW 30.00 kW 60.00 kW 150.0 kW 300.0 kW 1o3W 3.000 kW 6.000 kW 12.00 kW 30.00 kW 60.00 kW 120.0 kW 300.0 kW 600.0 kW 3o3W 3.000 kW 6.000 kW 12.00 kW 30.00 kW 60.00 kW 120.0 kW 300.0 kW 600.0 kW 3o4W 4.500 kW 9.000 kW 18.00 kW 45.00 kW 90.00 kW 180.0 kW 450.0 kW 900.0 kW 1o2W 2.250 kW 4.500 kW 9.000 kW 22.50 kW 45.00 kW 90.00 kW 225.0 kW 450.0 kW 1o3W 4.500 kW 9.000 kW 18.00 kW 45.00 kW 90.00 kW 180.0 kW 450.0 kW 900.0 kW 3o3W 4.500 kW 9.000 kW 18.00 kW 45.00 kW 90.00 kW 180.0 kW 450.0 kW 900.0 kW 3o4W 6.750 kW 13.50 kW 27.00 kW 67.50 kW 135.0 kW 270.0 kW 675.0 kW 1.350 MW *Electrical specifications: *Protocols: *Synchronization system: *Baud rates: Conforms to EIA RS-232 or EIA RS-485. CW120/121 proprietary protocol, Power Monitor protocol (Standard protocol used for YOKOGAWA M&C's Power Monitor) PC link communication (Standard protocol used for YOKOGAWA M&C's Temperature Controllers) MODBUS communication (ASCII or RTU) Start stop synchronization 1200, 2400, 4800, 9600, 19200, 38400 bps CW240 Communication Functions PC card interface PC card slot TYPE II ATA flash memory card Saving measurement data, saving and reading settings data Faulty Wiring Checking Functions *Check details: Presence/absence of power input; check for frequency measurement range; voltage phase sequence; presence/absence of power input; whether current clamp is reverse-connected CW120 *Slot: *Compatible card: *Function specifications: Scaling Function The VT ratio and CT ratio can be set. *Settings ranges VT ratio: 1-10,000 CT ratio: 1-10,000 (in increments of 0.01) External Control I/O (for RS-232 only; not provided for RS-485) Other Functions Clock (typical precision: 100 ppm), key lock, system reset General Specifications *Environmental requirements: Indoor usage at an altitude of 2000 meters or less. *Usage temperature and humidity ranges: 0-50C, 5-85% RH (no condensation) 0-40C, 5-85% RH (no condensation) for UL, C-UL *Storage temperature and humidity ranges: -20-60C, 90% RH (no condensation) *Insulating resistance: 500 V DC, 50 MW or greater Between voltage input terminals and case Between voltage input terminals and current input terminals, communication terminals, and control I/O terminals Between power line and case Between power line and current input terminals, communication terminals, and control I/O terminals *Insulating withstand voltage: 5550 V AC for one minute Between voltage input terminals and case 3320 V AC for one minute Between voltage input terminals and current input terminals, communication terminals, and control I/O terminals 2300 V AC for one minute Between power line and case Between power line and current input terminals, communication terminals, and control I/O terminals *Power supply: 100-240 V AC 10%, 50/60 Hz *Consumed power: 8 VA maximum *External magnetic field effects: Within accuracy levels at 400 A/m *External dimensions: Approximately 117 161 51 mm (W H D) *Weight: Approximately 0.6 kg *Terminals: Voltage input CW120: 3 terminals Banana terminals (safety terminals) CW121: 4 terminals Banana terminals (safety terminals) Current terminals CW120: 2 pairs Banana terminals (safety terminals) (H/L) CW121: 3 pairs Banana terminals (safety terminals) External control I/O 3 terminals (H/L/H) Screwless terminals terminals RS-485 4 terminals (+/-/SG/TM) M3 screw terminals *Connectors: RS-232: Mini DIN 8-pin AC power supply: 2-pin *Accessories: Voltage input probes: 3 for CW120, 4 for CW121 Power cord, user's manual, operation guide, Toolbox (setting software) *Safety standards: Compliant with EN61010-1, EN61010-2-031, UL3111-1 First Edition, CAN C22.2 No. 1010.1-92 - Voltage input line Measurement (Overvoltage) category III (Max. input voltage : 600 Vrms) - Power line Installation category II (Max. input voltage : 264 Vrms) Pollution degree 2 *EMC (emission): Compliant with EN55011, Group1, ClassA; EN61326; EN61000-3-2; EN61000-3-3 *EMC (immunity): Compliant with EN61326 AP240E These input and output can be used as signals for starting and stopping integrating measurement. *Control input: TTL level or contact *Control output: TTL level 17 CW240 Model and Suffix Code Model name and suffix code Model (Part No.) Suffix code Option code Accessories Carrying case Description Protective Cover CW240 93020 -D Power Cord (UL/CSA Standard) -F Power Cord (VDE Standard) -H Power Cord (GB Standard) -R Power Cord (SAA Standard) -S Power Cord (BS Standard) CW240 selection list for clamps Aim wiring to measure Number of clamps 1phase2wire1load 1 1phase2wire2load 2 Notes for selecting type of clamp probes Name Different clamps are selectable. 1phase2wire3load 3 1phase2wire4load 4 1phase3wire1load 2 Same clamps must be selected. 1phase3wire2load 4 Same clamps must be selected for each load. 3phase3wire1load 2 Same clamps must be selected. 3phase3wire2load 4 Same clamps must be selected for each load. 3phase3wire1load3currents 3 Same clamps must be selected. 3phase4wire 3 Same clamps must be selected. Scott wiring 4 Same clamps must be selected. Standard accessories comes with main unit 91007 Voltage probes, AC adapter x1, AA size alkaline battery x6, ToolBox240(CD-ROM) x1, User's Manual x1/CD-ROM version x1, Quick Manual x1/CD-ROM version x1, Communication function manual(CD-ROM) x1 18 CW240 main unit can be packed in the carrying case with accessories like current clamps and voltage probes, without disconnecting them from the main unit. It also holds the other accessories. 91022 To prevent error connection of clamp probes. Model No. Voltage probes (4 pcs/set) NiMH battery pack Memory Card (256MB) Memory Card (512MB) Memory Card (2GB) Printer AC adapter (for printer, Europe) AC adapter (for printer, USA) Thermal paper for printer (10 rolls) AC adapter for 96035 91007 94004 97034 97035 97037 97010 94006 94007 97080 94013 B9108WB AP240E CW viewer Description 256MB CF with PC Card Adapter 512MB CF with PC Card Adapter 2GB CF with PC Card Adapter Power Supply 200-240 VAC Power Supply 100-120 VAC For AC 120V For AC 220-240V CW120 Models and Suffix code Model name and suffix code Model (Part No.) Suffix code Option code Carrying case Three-phase 3-wire CW120 CW121 Power cord Accessories Description Main unit case 93022 Portable case 93023 93024 Three-phase 4-wire -D AC power cord (UL/CSA Standard) -F AC power cord (VDE Standard) -H AC power cord (GB Standard) -R AC power cord (SAA Standard) AC power cord (BS Standard) -S Communication -1 RS-232 communication interface -2 RS-485 communication interface CW120/CW121 selection list for clamps Aim wiring to measure Number of clamps Notes for selecting type of clamp probes 1 Same clamps must be selected. 1phase2wire2load 2 Same clamps must be selected. 1phase2wire3load 3 Same clamps must be selected for CW121. 1phase3wire1load 2 Same clamps must be selected. 3phase3wire1load 2 Same clamps must be selected. 3phase4wire 3 Same clamps must be selected for CW121. Accessories supplied at no extra cost Product Name Part No. Includes magnet and stand Power cable Printer 98030 1phase2wire1load 1. Power cord CW120 main unit can be packed in the carrying case with accessories like the current clamps and voltage probes. It also holds the other accessories. This cable supplies power from a measurement circuit. length 1.5m *Not applied to CE and UL. Name Qty 1 2. Voltage probes (for CW 120) 91018 3 Voltage probes (for CW 121) 91007 4 3. User's Manual IM CW120-E 1 4. Operation Guide IM CW-120P-E 1 97010 Voltage probe Voltage probe Communication cable Printer cable Model No. 91007 91018 91011 91010 97034 97035 97037 97010 94006 AC adapter (for printer, Europe) 94007 AC adapter (for printer, USA) Printer thermal paper 97080 AC adapter for 96035 94013 B9108WB CW viewer AP240E Memory Card (256MB) Memory Card (512MB) Memory Card (2GB) Printer Description Four per set Three per set RS232 communication cable for PC (9-pin) RS232 printer cable, length 1.5 m 256MB CF with PC Card Adapter 512MB CF with PC Card Adapter 2GB CF with PC Card Adapter Includes one roll of thermal paper and one battery pack Power Supply 200-240 VAC Power Supply 100-120 VAC 10 rolls For AC 120V For AC 220-240V Effective power supply quality and power saving management for PCs Data Analysis Program for CW240 /CW12x CW240 CWViewer AP240E AP240E report creation in line with your objectives. CW120 Powerful & Accurate measurement with the CW240 AP240E Increased quality and effectiveness of report creation CW Viewer AP240E is data analyzing software for the CW240 Clampon Power Meter. Making full use of the rich measuring functions of the CW240, this efficiently manages the large amounts of measurement data that are required in order to implement power quality management, energy management, and power saving measures. Furthermore, the quality and efficiency of report creation has been improved in order that reports to meet certain purposes can be easily created. Report creation in line with objectives Graph Display Daily Report Display, Weekly / Monthly Report Display Harmonic Graph Display Harmonics Instant Value Display Waveform Data Display Voltage Change Display Graph Daily Report 19 Report Creation Effective power supply quality and power saving management for PCs. Power quality and power saving management data measured with the CW240 AP240E report creation in line with your objectives Increased quality and effectiveness of report creation Bulk Data Management In order to edit measurement data to create reports that meet objectives, it is necessary to sort the required elements from a broad range of measurement data, and to set both the parameters for display, and items to display. CW Viewer AP240E carries out bulk management of data by registering measurement data and display parameters. Easy data registration, deletion, reference, and analysis means that the program is easy to use immediately, even for beginners. Bulk Management of Large Quantities of Measurement Data 20 Using the AP240E, it is easy to register a large amount of data measured with CW240 in the database, for integrated handling. 1 At the time of data registration, only the target files are displayed, and detailed information can be confirmed by selecting these files. 2 Measurement data can be searched by measurement date or group name. 3 Automatically links to measurement data such as that for waveforms and voltage changes. 4 Group names and comments can be added and registered. Registered Data Details dialog 1 2 3 4 Fast Reproduction of Past Reports Main screen CW Viewer AP240E links display parameters for graphs and records with measurement data, and saves this in the database, which means that reports that have been created in the past can be swiftly recreated in the same format. Simple Report Creation Select measurement data, and click the Data Display button to edit reports. Settings of display items is easy, and items such as graphs and daily reports are easy to create. Simple Operation Pick out target elements from large amounts of data. Clear Display 1 Items that can be selected when setting display items are displayed 2 in a list, which means that measurement data items that are required for carrying out power management and power quality management 3 can be efficiently selected to meet objectives. 4 1Up to a maximum of 8 items can be set for both the left and right Item Selection dialog axes. 2 Display items, units, and scale, etc. can be selected from the list. 3 Desired maximum and minimum values for the graph scale can be set. Additionally, the Automatic Settings button can be used to set optimal values. 4 This is also convenient for comparisons with power reduction targets, by setting standard values. Easy Setting of Focus Times Setting the start and period of the focus times enables setting of a range of part (or all) of the measurement data. 1The display start time can be specified from the range of existing measurement data. 2 The specified display range can be moved easily using these 1 buttons. 3 The graph display period (the whole period or a desired period) 2 can be specified. 3 4 4 A desired range (more than the measurement cycle) can be specified. Focus Period settings Data Analysis Program CW Viewer AP240E Report formats that can be selected as a result of the types of measurement data are displayed on tabs. Report formats in line with objectives can be easily selected with tabs from a variety of report presentations. CW240 Variety of Presentations in Line with Objectives Selection of Report Formats with Tabs Tab Selection Graph display can be changed (line type, line thickness, and line color, markers, etc.) in line with objectives, and multiple measurement data can be displayed on the report in an easy to see manner. AP240E Easy-to-see Graph Display CW120 Report formats such as graph display, daily report display, harmonics graph and voltage change can be easily switched by selection with tabs. Superimposed Display of Multiple Waveforms A channel, system, and type can be selected for each measurement item such as power, voltage, and current, and up to 8 items can be simultaneously displayed on the graph for each of the left and right vertical axes (a total of 16 items). This enables the comparative display per channel and system of multiple data items. Graph Display Harmonics Data Analysis Harmonics graphs are displayed by selecting the desired degree from amongst 50. Harmonics trend graphs and harmonics instant value graphs can be selected with tabs, and in the harmonics instant value tab, all harmonics levels, harmonics content ratios, and phase differences can be displayed. Vector display of power phase differences is also possible. Harmonics Trend Display Harmonics Instant Value Display 21 Waveform Data Display Displays as a graph waveform data (maximum of 7 for each of four systems) measured with the CW240. Irregularities in voltage and current waveforms for each phase can be viewed at a glance, making for effective management of electrical power quality (current situation and confirmation of measures taken). Power Phase Difference Vector Diagram Display Waveform Display One-Touch Selection of Daily and Weekly Reports Daily Report Display Demand measurement values for power consumption are displayed in time units (30 minutes or 1 hour) as daily reports, simply by selecting the desired demand measurement items. Furthermore, load and demand ratio calculations are carried out automatically by setting capacitance values for facilities. Weekly and Monthly Report Display Demand measurement values for power consumption in 1 day units are displayed as weekly and monthly reports. Load and demand ratio calculations are carried out automatically in the same way as with daily reports. Voltage Change Display Displays in a list voltage drops, rises, and momentary power interruption detection data and detection time. This enables confirmation of the start, end, and period of voltage changes. Record Display When the graph display, harmonics trend display, and harmonics instant value display tabs have been selected, numerical data for the displayed graph range can be displayed as a record. Daily Report Display Voltage Change Display Records Display Report Creation Effective power supply quality and power saving management for PCs. Report Creation Customization Functions Graph and Record Printing Print graphs and records by using the Print buttons on the graph display screen and records screen. Additionally, when printing, the preview screen will allow confirmation of output. Selectable Printer Type Printer configuration is possible in order that either color or monochrome are printed correctly. Print Preview AP240E Analysis Data can be Further Edited in MS Excel and Word Graph Copy Pasting Records Pasting Graphs The portion of the graph on the displayed screen can be copied to the clipboard by using the Graph Copy button on the graph screen. This enables graph images that are created in CW Viewer AP240E to be pasted into Excel or Word documents. Power phase difference vector diagrams and waveform data are also handled in the same way. Record Copy By using the Record Copy button in the same way as with graphs, record data can be copied to the clipboard. Record data is copied as text data. 22 Saving Record Data as CSV Format Files The range of data displayed on the daily report, monthly report, and record screens can be saved as CSV format files. CSV files can be used in spreadsheet software; this is convenient for secondary analysis of measurement data, and creation of original reports. Example of Copying Graphs and Records Useful Functions Analog Input Data Scaling for analog input data settings, and unit settings can be carried out. This enables comparison of measurement data such as temperature and lighting density with data such as used energy. Voltage Unbalance Ratio Display Automatically measures voltage unbalance ratios when CH1 ~ CH3 voltage is measured, and can display as a graph in the same way as with other measurement data items. Scaling Settings Default Settings Frequently used unit settings, graph display parameter settings, and group name settings, etc. can be registered as defaults in advance. Display Settings / Measurement Parameter Display Settings parameters and measurement intervals, etc. at the time of measurement are displayed on the top of the tabs on the data display screen, enabling constant confirmation by selecting tabs even if the report format is changed. Default Settings Measurement Parameter Display Data Analysis Program CW Viewer AP240E CW240 AP240E Specifications Graph Display *Graph display of up to 8 items on each of the left and right axes possible. *Selection of display items an ordered list possible. *Settings of units, decimal points, minimum values, and maximum values, as well as automatic adjustment for each of the left and right axes possible. *Graph customization (line type, line thickness marker, color) possible. *Setting of the graph display period (focused time, period, measurement cycle) possible. *Movement of the graph display period possible. *Graph interpolation of non-measured segments possible. Harmonic Graph Display *Displays the harmonics graph tab where there is harmonics measurement data. *Selection of degree data up to a maximum of 50 degrees possible. AP240E Data Display Selection * Always display measurement parameters on the data display screen. * Selection by the use of tabs to select report displays (graph display, daily report display, weekly / monthly report display, harmonic graph display, harmonics instant value display, waveform data display, voltage change display) possible. Daily Report Display, Weekly / Monthly Report Display *Displays the daily report, and weekly / monthly report tabs where there is demand measurement data. *Displays selected demand measurement values per time (or date). *Selection of display intervals for daily report display (1 hour / 30 minutes) possible. *Can set the equipment capacity, and automatically calculate load ratios and demand ratios. CW120 Data Management * Display of measurement parameters when measurement data is registered. * Registration in the database of measurement date, measurement parameters, group names, and comments added to measurement data possible. * Bulk management of data such as harmonics data, waveform data, and voltage change data. *Editing of data names, comments, and group names possible. *Searching by measurement dates / periods, and group names possible. *Saving of settings information at the time the report was displayed, and that corresponds to data. *Setting of defaults for a range of settings data possible. Harmonics Instant Value Display *Displays the harmonics graph tab when there is harmonics measurement data. *Selection of degrees of up to 50 possible. *Display of power phase difference vector diagrams possible. 23 Waveform Data Display *Displays the waveform data tab when there is waveform data. *Display of selected waveform data. Voltage Change Display *Displays the voltage change data tab when there is voltage change detection data. *Displays voltage change data per detection time. *Selection of display items (voltage dip, voltage swell, detected momentary power interruptions) possible. Package contents Contents AP240E installation CD User registration card 1 1 Common Accessories for CW120/121 and CW240 Item Measuring range Output voltage Accuracy Amplitude 96030 Clamp-on Current Probe 0-200 Arms AC (300 Apk) 0-0.5 Vrms AC (2.5 mV/A) 96031 Clamp-on Current Probe 0-500 Arms AC (750 Apk) 0-0.5 Vrms AC (1 mV/A) 96032 Clamp-on Current Probe 0-700 Arms AC (990 Apk) 1000 Arms (1414 Apk) for 5 minutes 1.5% rdg 0.4 mV (20 Hz to 45 Hz) 0.5% rdg 0.1 mV (45 Hz to 66 Hz) 0.8% rdg 0.2 mV (66 Hz to 1 kHz) 2.0% rdg 0.4 mV (1 kHz to 20 kHz) 1.5% rdg 0.4 mV (20 Hz to 45 Hz) 0.5% rdg 0.1 mV (45 Hz to 66 Hz) 0.8% rdg 0.2 mV (66 Hz to 1 kHz) 0-0.25 Vrms AC (0.25 mV/A) 1.0% rdg 0.2 mV (45 Hz to 66 Hz) 0.5 (45 Hz to 1 kHz) 1.0 (45 Hz to 1 kHz) 1.0 (50 A or more, 45 Hz to 66 Hz) Phase 96033 Clamp-on Current Probe 0-50 Arms AC 0-0.5 Vrms AC (10 mV/A) 1.0% rdg 0.3 mV (20 Hz to 45 Hz) 0.5% rdg 0.1 mV (45 Hz to 66 Hz) 0.8% rdg 0.2 mV (66 Hz to 1 kHz) 1.0% rdg 0.3 mV (1 kHz to 5 kHz) 3% rdg 0.4 mV (5 kHz to 20 kHz) 1.0 (45 Hz to 1 kHz) 96036Clamp-on Current Probe 0-2Arms AC (20Apk) 0-0mVrms AC (25mV/A) 1.5%rdg0.04mV (20Hz-45Hz) 0.5%rdg0.01mV (45Hz-66Hz) 0.8%rdg0.02mV (66Hz-1kHz) 2%rdg0.04mV (1kHz-5kHz) 2 (45Hz-3.5kHz) (for temperature of 23C 5C, relative humidity of 35-75%, and sine wave input) Output impedance External magnetic field effects Approx. 18 Approx. 100 (max.) Approx. 2.4 Approx. 6 Approx.70 2mA equivalent or less (at 400A/m, 50/60Hz) 0.1 A equivalent or less (at 400 A/m, 50/60 Hz) 0.2 A equivalent or less (at 400 A/m, 50/60 Hz) 0.5 A equivalent or less (at 400 A/m, 50/60 Hz) 0.1 A equivalent or less (at 400 A/m, 50/60 Hz) Conductor position effects 0.5% (at 20-200 A, 45 Hz to 1 kHz) 0.5% (at 50-500 A, 45 Hz to 1 kHz) 0.5% (at 200-1000 A, 45 Hz to 66 Hz) 0.5% (at 1-50 A, 45 Hz to 1 kHz) 0.5% (at 0.2-2A, 45Hz-1kHz) 300 Vrms AC max. Approx. 100 (W) x 172.5 (H) x 32 (D) mm Approx. 52 (W) x 106 (H) x 25 (D) mm (excluding protrusions) Approx. 220 g Approx. 500 g Approx. 3 meters 600 Vrms AC max. Approx. 73 (W) x 130 (H) x 30 (D) mm Approx. 300 g Operating circuit voltage External dimensions Weight Output cable length 50Vrms AC max. Approx.70(W)120(H)25(D)mm Approx.300g External Dimensions Item Range type Measuring range Output voltage Accuracy Amplitude (for temperature of 23C 5C, relative humidity Phase of 20-70%, and sine wave input) Maximum allowable current (600 Hz or less) 1000 A 0-1000 Arms AC 0-0.5 Vrms AC (0.5 mV/A) 96034 Clamp-on Current Probe 2000 A 0-2000 Arms AC 0-0.5 Vrms AC (0.25 mV/A) 3000 A 0-3000 Arms AC 0-0.5 Vrms AC (0.1667 mV/A) 1% rdg +0.045 mV (1-20 A) 1% rdg (20-1200 A) 1% rdg +0.0225 mV (1-20 A) 1% rdg (20-2400 A) 1% rdg +0.015 mV (1-20 A) 1% rdg (20-3600 A) 1% rdg (5-3000 A, 45 Hz to 66 Hz) 3% rdg (100 A, 10 Hz to 10 kHz) 1% rdg (5-300 A, 45 Hz to 66 Hz) 5% rdg (100 A, 10 Hz to 10 kHz) Not specified (1-20 A) 1.0 (20-200 A) 0.5 (200-1200 A) Not specified (1-20 A) 1.0 (20-200 A) 0.5 (200-2400 A) Not specified (1-20 A) 1.0 (20-200 A) 0.5 (200-3600 A) 1 (5-3000 A, 45 Hz to 66 Hz) 4 (200 A, 40 Hz to 1 kHz) 1 (5-300 A, 45 Hz to 66 Hz) 7 (200 A, 40 Hz to 1 kHz) 1200 Arms AC (continuous) 2400 Arms AC (continuous) 2400-2800 Arms AC (for 15 minutes) 2800-3600 Arms AC (for 10 minutes) 3600 Arms AC (10 Hz to 1 kHz) 360 Arms AC 96035 Clamp-on Current Probe 3000 A 300 A 0-3000 Arms AC 0-300 Arms AC 0-0.5 Vrms AC (0.1667 mV/A) 0-0.5 Vrms AC (1.667 mV/A) 2 or less Output impedance Approx. 47 External magnetic field effects 0.1% of full scale (at 400 A/m, 50/60 Hz) Conductor position effects Operating circuit voltage Measurable conductor diameter 1% +0.2 A or less 2% of full scale 600 Vrms AC max. Main unit: 600 Vrms AC max. Measuring unit: 1000 Vrms AC max. o64 x 100 mm, five 125 x 5 mm bus bars, or three 100 x 10 mm bus bars o170 mm max. Approx. 310 (W) x 120 (H) x 48 (D) mm Main unit: Approx. 140 (W) x 64 (H) x 28 (D) mm Measuring unit: Approx. 610 mm External dimensions Weight Main unit: Approx. 300 g (including battery and output cable) Measuring unit: Approx. 180 g Approx. 1400 g Output cable length Output terminal Approx. 3 meters Banana plug (safety terminal) 9 V alkaline battery (6LF22) AC Adapter Power supply Continuous measurement: 150 hours Intermittent measurement: 10,000 times unit: mm 96030,31 24.7 73 unit: mm 96033 100 66 52 69 106 172.5 86 130 71 30 unit: mm 96032 57 60 30 25 unit: mm 96034 48 unit: mm 96035 40 unit: mm 96036 120 Air-core Length: approx. 610mm Weight: approx. 180g 64 310 120 o40 3000 28 140 Box Weight: approx. 300g (including a battery and output cable) 40 25 55.6 NOTICE World Wide Web site at http://www.yokogawa.com/ymi YOKOGAWA METERS & INSTRUMENTS CORPORATION Tachihi Bld. No.2, 6-1-3 Sakaecho, Tachikawa-shi, Tokyo, 190-8586 Japan Phone: +81-42-534-1413 Facsimile: +81-42-534-1426 International Sales Dept. YOKOGAWA CORPORATION OF AMERICA (U.S.A.) YOKOGAWA EUROPE B. V. (THE NETHERLANDS) YOKOGAWA ENGINEERING ASIA PTE. LTD. (SINGAPORE) YOKOGAWA AMERICA DO SUL LTDA (BRAZIL) YOKOGAWA MEASURING INSTRUMENTS KOREA CORPORATION (KOREA) YOKOGAWA AUSTRALIA PTY. LTD. (AUSTRALIA) YOKOGAWA INDIA LTD. (INDIA) YOKOGAWA SHANGHAI TRADING CO., LTD. (CHINA) YOKOGAWA MIDDLE EAST B. S. C.(C) (BAHRAIN) YOKOGAWA ELECTRIC CIS LTD. (RUSSIAN FEDERATION) Phone: +1-770-253-7000 Phone: +31-88-4641000 Phone: +65-6241-9933 Phone: +55-11-5681-2400 Phone: +82-2-551-0660 Phone: +61-2-8870-1100 Phone: +91-80-4158-6000 Phone: +86-21-6239-6363 Phone: +973-17-358100 Phone: +7-495-737-7868 Subject to change without notice. All Rights Reserved. Copyright (c) 2002, Yokogawa Meters & Instruments Corporation. Facsimile: +1-770-254-0928 Facsimile: +31-88-4641111 Facsimile: +65-6241-2606 Facsimile: +55-11-5681-4434 Facsimile: +82-2-551-0665 Facsimile: +61-2-8870-1111 Facsimile: +91-80-2852-1441 Facsimile: +86-21-6880-4987 Facsimile: +973-17-336100 Facsimile: +7-495-737-7869 [Ed: 11/b] Before using the product, read the instruction manual carefully to ensure proper and safe operation. Represented by: MIK-ES17 Printed in Japan: Mar. 2011(C)/5,000(KP) Clamp-On Power Meters Part Number Description CW121-D/SP1 CW121-D Clamp Meter with standard accessories and 93037 Carrying case and 94009 Lithium ion battery CW240-D/SP1 CW240-D Clamp Meter with standard accessories and 93037 Carrying case and 94009 Lithium ion battery Contact Information: www.Farnell.co.uk www.Newark.com