AQ8-RELAYS SOLID STATE RELAY UL File No.: E95895 CSA File No.: LR26550 9 .354 45 1.772 24 .945 mm inch FEATURES 1. So slim with 9 mm .354 inch thickness The thin type (45 mm long x 24 mm high x 9 mm wide) (1.772 x .945 x .354 inch) permits high density mounting. 2. Excellent in noise resistance Since the input and output are insulated by the photo TRIAC coupler, the noise on the output side is not fed back to the input side. 3. Snubber circuit integrated The snubber circuit is integrated to prevent malfunction caused by the rapid rise of the voltage on the output side, such as inductive load and noise. 4. Zero-cross and nonzero-cross types are available. The zero-cross type generates minimal noise by suppressing occurrence of radio frequency interference (RFI) and electromagnetic interference (EMI). The nonzero-cross type features a short operation time which permits phase control. 5. High dielectric strength: 3,000 V AC (between input and output) 6. Two kinds of terminals distance are available. (5.08 mm and 7.62 mm) (.200 and .300 inch) 7. High reliability, long life and maintenance-free APPLICATIONS Most suitable as drivers for small size AC motors, solenoids, solenoid valves and so on. 1. Copying equipment 2. Air conditioners 3. Industrial equipment such as NC machines, sequencers, robots and so on TYPES 1. Zero-cross type Input terminals distance Max. load current 2. Nonzero-cross type Load voltage 75 to 125 V AC 2A 75 to 250 V AC 5.08 mm .200 inch type 75 to 125 V AC 3A 75 to 250 V AC 75 to 125 V AC 2A 75 to 250 V AC 7.62 mm .300 inch type 75 to 125 V AC 3A 75 to 250 V AC Input voltage Part No. 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC AQ2A1-C1-ZT5VDC AQ2A1-C1-ZT12VDC AQ2A1-C1-ZT24VDC AQ2A2-C1-ZT5VDC AQ2A2-C1-ZT12VDC AQ2A2-C1-ZT24VDC AQ3A1-C1-ZT5VDC AQ3A1-C1-ZT12VDC AQ3A1-C1-ZT24VDC AQ3A2-C1-ZT5VDC AQ3A2-C1-ZT12VDC AQ3A2-C1-ZT24VDC AQ2A1-C2-ZT5VDC AQ2A1-C2-ZT12VDC AQ2A1-C2-ZT24VDC AQ2A2-C2-ZT5VDC AQ2A2-C2-ZT12VDC AQ2A2-C2-ZT24VDC AQ3A1-C2-ZT5VDC AQ3A1-C2-ZT12VDC AQ3A1-C2-ZT24VDC AQ3A2-C2-ZT5VDC AQ3A2-C2-ZT12VDC AQ3A2-C2-ZT24VDC Remark: Standard packing Carton: 20 pcs.; Case: 200 pcs. Input terminals distance Max. load current Load voltage 75 to 125 V AC 2A 75 to 250 V AC 5.08 mm .200 inch type 75 to 125 V AC 3A 75 to 250 V AC 75 to 125 V AC 2A 75 to 250 V AC 7.62 mm .300 inch type 75 to 125 V AC 3A 75 to 250 V AC Input voltage Part No. 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC AQ2A1-C1-T5VDC AQ2A1-C1-T12VDC AQ2A1-C1-T24VDC AQ2A2-C1-T5VDC AQ2A2-C1-T12VDC AQ2A2-C1-T24VDC AQ3A1-C1-T5VDC AQ3A1-C1-T12VDC AQ3A1-C1-T24VDC AQ3A2-C1-T5VDC AQ3A2-C1-T12VDC AQ3A2-C1-T24VDC AQ2A1-C2-T5VDC AQ2A1-C2-T12VDC AQ2A1-C2-T24VDC AQ2A2-C2-T5VDC AQ2A2-C2-T12VDC AQ2A2-C2-T24VDC AQ3A1-C2-T5VDC AQ3A1-C2-T12VDC AQ3A1-C2-T24VDC AQ3A2-C2-T5VDC AQ3A2-C2-T12VDC AQ3A2-C2-T24VDC RATINGS 1. Ratings (Ambient temperature: 20C, 68F; Voltage ripple on the input side: 1% or less) 1) Zero-cross type * 2 A type Part No. AQ2A1-C1-ZT5VDC AQ2A1-C1-ZT12VDC AQ2A1-C1-ZT24VDC AQ2A2-C1-ZT5VDC AQ2A1-C2-ZT5VDC AQ2A1-C2-ZT12VDC Input side Item Control voltage 5 V DC (4 to 6V) AQ2A1-C2-ZT24VDC AQ2A2-C2-ZT5VDC 12 V DC 24 V DC (9.6 to 14.4V) (21.6 to 26.4 V) Remarks The parenthesized 12 V DC 24 V DC values represent the (9.6 to 14.4V) (21.6 to 26.4 V) allowable voltage ranges Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Drop-out voltage min. 0.5 V min. 1.2 V min. 2.4 V min. 0.5 V min. 1.2 V min. 2.4 V Max. load current Load side 5 V DC (4 to 6V) AQ2A2-C1-ZT12VDC AQ2A2-C1-ZT24VDC AQ2A2-C2-ZT12VDC AQ2A2-C2-ZT24VDC At ambient temperature of 30C or less 2 A*1 Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V 30 A*2 In one cycle at 60 Hz 5 mA/200 V applied 2.5 mA/100 V applied 1.6 V at max. carrying current 25 mA* 50 mA* 3 3 OFF state dV/dt At ambient temperature of 80C 50 V/s * 3 A type Part No. AQ3A1-C1-ZT5VDC AQ3A1-C1-ZT12VDC AQ3A1-C1-ZT24VDC AQ3A2-C1-ZT5VDC Input side Item Control voltage AQ3A1-C2-ZT5VDC AQ3A1-C2-ZT12VDC 5 V DC (4 to 6V) AQ3A1-C2-ZT24VDC AQ3A2-C2-ZT5VDC 12 V DC 24 V DC (9.6 to 14.4V) (21.6 to 26.4 V) Remarks The parenthesized 12 V DC 24 V DC values represent the (9.6 to 14.4V) (21.6 to 26.4 V) allowable voltage ranges Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Drop-out voltage min. 0.5 V min. 1.2 V min. 2.4 V min. 0.5 V min. 1.2 V min. 2.4 V Max. load current Load side 5 V DC (4 to 6V) AQ3A2-C1-ZT12VDC AQ3A2-C1-ZT24VDC AQ3A2-C2-ZT12VDC AQ3A2-C2-ZT24VDC Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current OFF state dV/dt At ambient temperature of 30C or less 3 A*1 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V 80 A*2 2.5 mA/100 V applied In one cycle at 60 Hz 5 mA/200 V applied 1.6 V 25 mA*3 at max. carrying current 50 mA*3 50 V/s Notes: *1) Refer Data 1, characteristics of load current vs. ambient temperature. *2) Refer to Data 2, characteristics of non-repetitive surge current vs. carrying time. *3) When the load current is less than the min. load current, refer to "Cautions for Use (Page 486)". At ambient temperature of 80C 2) Non zero-cross type * 2 A type Part No. AQ2A1-C1-T5VDC AQ2A1-C2-T5VDC Input side Item Control voltage Input impedance Drop-out voltage 5 V DC (4 to 6V) AQ2A1-C1-T12VDC AQ2A1-C2-T12VDC AQ2A1-C1-T24VDC AQ2A1-C2-T24VDC 12 V DC 24 V DC (9.6 to 14.4V) (21.6 to 26.4 V) Approx. 0.3 k Approx. 0.8 k min. 0.5 V min. 1.2 V AQ2A2-C1-T12VDC AQ2A2-C2-T12VDC min. 2.4 V AQ2A2-C1-T24VDC AQ2A2-C2-T24VDC Approx. 0.8 k Approx. 1.8 k min. 1.2 V min. 2.4 V min. 0.5 V At ambient temperature of 30C or less 2 A* 1 Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current Remarks The parenthesized 12 V DC 24 V DC values represent the (9.6 to 14.4V) (21.6 to 26.4 V) allowable voltage ranges 5 V DC (4 to 6V) Approx. 1.8 k Approx. 0.3 k Max. load current Load side AQ2A2-C1-T5VDC AQ2A2-C2-T5VDC 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V 30 A*2 In one cycle at 60 Hz 5 mA/200 V applied 2.5 mA/100 V applied 1.6 V at max. load current 25 mA*3 50 mA*3 OFF state dv/dt At ambient temperature of 80C 50 V/s * 3 A type Part No. AQ3A1-C1-T5VDC AQ3A1-C2-T5VDC Input side Item Control voltage Input impedance Drop-out voltage 5 V DC (4 to 6V) AQ3A1-C1-T12VDC AQ3A1-C2-T12VDC AQ3A1-C1-T24VDC AQ3A1-C2-T24VDC 12 V DC 24 V DC (9.6 to 14.4V) (21.6 to 26.4 V) Approx. 0.3 k Approx. 0.8 k min. 0.5 V min. 1.2 V AQ3A2-C1-T12VDC AQ3A2-C2-T12VDC min. 2.4 V AQ3A2-C1-T24VDC AQ3A2-C2-T24VDC Approx. 0.8 k Approx. 1.8 k min. 1.2 V min. 2.4 V min. 0.5 V At ambient temperature of 30C or less 3 A*1 Load voltage Frequency Repetitive peak OFF voltage Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current Remarks The parenthesized 12 V DC 24 V DC values represent the (9.6 to 14.4V) (21.6 to 26.4 V) allowable voltage ranges 5 V DC (4 to 6V) Approx. 1.8 k Approx. 0.3 k Max. load current Load side AQ3A2-C1-T5VDC AQ3A2-C2-T5VDC 75 to 125 V AC 75 to 250 V AC 45 to 65 Hz 400 V 600 V 80 A*2 In one cycle at 60 Hz 5 mA/200 V applied 2.5 mA/100 V applied 1.6 V at max. carrying current 25 mA* 50 mA* 3 3 OFF state dv/dt At ambient temperature of 80C 50 V/s Notes: *1) Refer to Data 1, characteristics of load current vs. ambient temperature. *2) Refer to Data 2, characteristics of non-repetitive surge current vs. carrying time. *3) When the load current is less than the min. load current, refer to "Points to note for operation". 2. Characteristics (Amdient temperature: 20C 68F; Input voltage ripple: 1% or less) Type Item Operate time, max. Release time, max. 1/2 cycle of voltage sine wave + 1 ms 1 ms Remarks 1/2 cycle of voltage sine wave + 1 ms at 500 V DC 3,000 V AC between input and output For 1 minute Functional 10 to 55 Hz at double amplitude of 3 mm 10 min. for X, Y, Z axis Destructive 10 to 55 Hz at double amplitude of 3 mm 1 hour for X, Y, Z axis Breakdown voltage Shock resistance Non-zero-cross type 109 between input and output Insulation resistance, min. Vibration resistance Zero-cross type 2 Functional Min. 980 m/s {100 G} 4 times each for X, Y, Z axis Destructive Min. 980 m/s2 {100 G} 5 times each for X, Y, Z axis Ambient temperature -30C to +80C -22F to +176F Storage temperature -30C to +100C -22F to +212F Operational method Zero-cross (Turn ON and Turn OFF) Random turn ON, zero-cross turn OFF DIMENSIONS mm inch Mounting hole location (Bottom view) (Common for zero-cross and nonzero-cross types) 9 max. .354 45 max. 1.772 Terminal 4 1. Input terminals distance 5.08 mm .200 inch 1) 2 A type - 4INPUT3 + 3 2.54 x 2 .100 x 2 24 max. .945 Copper foil 27.94 1.100 2 1 2.54 x 4 .100 x 4 2.54 x 5 .100 x5 4-1.2 dia. 4-.047 Tolerance: 0.1 .004 Schematic 2 LOAD 1 8 min. .315 5.08 .200 4 3 2) 3 A type LOAD 2 1 INPUT 4 3 5.08 .200 10.16 .400 12.7 .500 4-0.8 dia. 4-.031 2.5 .098 2 1 General tolerance: 0.5 .020 9 max. .354 43 max. 1.693 - + Load Input Load power source power source Mounting hole location (Bottom view) Terminal 4 - 4INPUT3 + 4 2. Input terminals distance 7.62 mm .300 inch 1) 2A type 2.54 x 4 .100 x 4 4-1.2 dia. 4-.047 2 LOAD 1 5.08 .200 10.16 .400 12.7 .500 3 2.54 x 5 .100 x5 1 Tolerance: 0.1 .004 Schematic 8 min. .315 5.08 .200 3 2.54 x 2 .100 x 2 32 max. 1.259 Copper foil 27.94 1.100 2 2 INPUT 4 3 LOAD 2 1 4-0.8 dia. 4-.031 2.5 .098 General tolerance: 0.5 .020 1 - + Load Load Input power source power source Mounting hole location (Bottom view) 9 max. .354 45 max. 1.772 Terminal 4 - 4INPUT 3+ 3 2.54 x 3 .100 x 3 24 max. .945 30.48 1.200 2 2.54 x 5 .100 x 5 Copper foil 1 2.54 x 4 .100 x 4 4-1.2 dia. 4-.047 Tolerance: 0.1 .004 Schematic 2 LOAD 1 8 min. .315 7.62 .300 4 5.08 .200 10.16 .400 12.7 .500 3 2) 3 A type 2 INPUT 4 3 4-0.8 dia. 4-.031 2.5 .098 1 General tolerance: 0.5 .020 9 max. .354 43 max. 1.693 - + Load Input Load power source power source Mounting hole location (Bottom view) Terminal 4 32 max. 1.259 - 4 INPUT3+ 4 3 12.7 .500 30.48 1.200 2 3 2.54 x 3 .100 x 3 2.54 x 5 .100 x 5 5.08 .200 10.16 .400 2 INPUT 4 3 LOAD 2 1 4-0.8 dia. 4-.031 2.5 .098 1 General tolerance: 0.5 .020 Copper foil 1 2.54 x 4 .100 x 4 4-1.2 dia. 4-.047 Tolerance: 0.1 .004 Schematic 2 LOAD 1 8 min. .315 7.62 .300 LOAD 2 1 - + Load Input Load power source power source AQ8 REFERENCE DATA (2 A type) 3 A type 2.5 2 A type 2.0 1.5 1.0 (3 A type) Non-repetitive surge current, A 3.0 Load current, A 2. Characteristics of non-repetitive surge current vs. carrying time Non-repetitive surge current, A 1. Characteristics of load current vs. ambient temperature Conditions: Natural cooling 100 80 60 40 20 0.5 0 -30 0 3. Characteristics of input current vs. input voltage zero-cross type Nonzero-cross type 80 60 40 20 0 20 40 60 80 Ambient temperature, C 100 5 10 50 No. of cycles at 60 Hz 0 100 5 10 50 No. of cycles at 60 Hz 100 4. Characteristics of load current vs. ambient temperature for adjacent mounting Conditions: Natural cooling (2 A type) (3 A type) 30 2.5 3.0 20 15 (12 V type) 10 (24 V type) 1.5 Load current, A R=20.32 mm .800 inch R=12.7 mm .500 inch R=9.0 mm .354 inch 2.0 Load current, A Input current, mA 25 1.0 2.0 1.0 (5 V type) 0.5 5 R R R R=Adjacent mounting pitch 0 0 10 0 -30 20 30 Input voltage, V 0 Product name 20 40 60 80 Ambient temperature, C Qualified ratings UL E95895 2A type: 2 A 125, 250 V AC 2 A 125 V AC (Tungsten) FLA 1 A, LRA 6 A 125, 250 V AC CSA LR26550 20 40 60 80 Ambient temperature, C 1. When used for the load less than rated In case of the load current less than rated, malfunction may result from the residual voltage across the both ends of the load even if the solid state relay is turned off. Use a dummy resistor as a countermeasure. The total of the current through the resistor and the load current must exceed the min. rated load current. 3A type: 3 A 125, 250 V AC 3 A 125 V AC (Tungsten) FLA 1.5 A, LRA 9 A 125, 250 V AC * Characteristics of load impedance vs. residual voltage R0 Dummy resistor 1 0 NOTES File No. AQ8 R R=Adjacent mounting pitch 0 -30 Approved standards list SSR R=20.32 mm .800 inch R=12.7 mm .500 inch R=9.0 mm .354 inch Load Load power source 2 100 80 f= 60Hz Ve: Residual voltage V: Power voltage Load 1 In case the dummy resistor is not used, keep in mind that the residual voltage becomes as follows: Example: For the inductive load by the 20 mA load current and the 200 V AC load voltage, the load impedance becomes 10 k and Ve/V = 14% is estimated from the right above graph. Accordingly, the 28 V voltage remains across the both ends of the load when the solid state relay is turned off. 60 Ve x 100 V (%) 40 SSR 2 V Ve Max. 45 Power factor: 1 (resistor load) Power factor: 0.4 (induction load) 20 0 10 2. Solder the terminals within 5 seconds at 260C 500F. 3. when the terminal is bent Care shall be taken neither to apply mechanical stresses to the mold area of the solid state relay nor to bend the terminal 45 degrees or more. 20 30 40 Solid state relay 50 Printed board Solder Load impedance (k) For Cautions for Use 6/1/1999 All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd. Go To Online Catalog