MICRO SWITCH
Military-Grade Toggle Switches
TL Series
Datasheet
2sensing.honeywell.com
What makes our switches better?
MIL-DTL-3950 qualified switches available to meet military
specifications
Environmental sealing enables switches to withstand many
demanding indoor and outdoor applications
1-, 2-, and 4-pole options for a variety of circuitry
requirements
2- and 3-position, maintained and momentary toggle action
to meet circuit and actuator requirements
UL recognized, CSA certified, and
CE approved for global use
MICRO SWITCH TL Series
Toggle Switches
Honeywell MICRO SWITCH TL Series toggle switches are military qualied to MIL-DTL-3950, specications for sealed
toggle switches. Quality construction features include a bonded seal between the toggle lever and bushing, and
between the cover and case.
The robust design of the TL Series toggle is well-suited for many military, aerospace and other demanding applications
where reliability is essential. These applications include environments where the panels are subjected to mechanical
shock, vibration, and temperature extremes as well as environments with dust, splashing or hose-directed water.
TL Series toggle switches offer a variety of circuitry and pole options to easily integrate into a number of applications.
A long history in military and aerospace applications has shown the TL Series toggle provides reliable performance with
long operating life under the toughest conditions.
MILITARY QUALIFIED • GLOBAL APPROVALS
MULTI-CIRCUITS • HIGH PERFORMANCE
ATTENTION!!
TL Series toggles are qualified
for military duty!
3
sensing.honeywell.com
Features
and Benefits
MIL-QUALIFIED AND GLOBAL APPROVALS
MIL-DTL-3950 qualified switches are available to meet military/aerospace
specifications. TL Series toggles’ environmental sealing enables switches to
withstand many demanding indoor and outdoor applications. Quality construction
includes a bonded seal between the toggle lever and bushing, and between
the cover and case that enables switches to withstand may demanding
conditions. UL recognized, CSA certified, and CE approved for global use
VARIETY OF CIRCUITRIES AND OPERATING ACTIONS
TL Series’ 1, 2, and 4 pole options meet a variety of circuitry requirements; while
2- and 3-position, maintained and momentary toggle action, for a breadth of
circuitry and actuator requirements. They thrive in a wide range of temperatures:
-65 °C to 71 °C [-85 °F to 160 °F]
LOCKING LEVERS
Optional lever locks (pull-to-unlock) require two separate actions to actuate the
switch in order to prevent unintended actuation
MULTIPLE CONNECTION OPTIONS
MICRO SWITCH TL Series toggles offer three popular termination options:
screw, solder lugs, and IWTS (Integrated Wire Termination Systems)
EASILY CONTROLS LOW-VOLTAGE DC APPLICATIONS
Toggle switches available with a choice of silver alloy or gold-plated contacts
to handle a variety of electrical load requirements
INNOVATIVE PRODUCT DESIGN
Engineered step-design case provides added space between terminals to
prevent shorting
ROBUST CONSTRUCTION
Built from military-grade components to achieve MIL-DTL-3950 requirements
Locking levers reduce unintended actuation
Military-qualified listings
4sensing.honeywell.com
MILITARY AND COMMERCIAL AIRCRAFT AND HELICOPTERS
Used in fixed wing aircraft and helicopter flight decks. Honeywell has a long history
of providing TL Series toggle switches in commercial and military aircraft.
AVIATION GROUND SUPPORT EQUIPMENT
Used to turn on and operate various components of aviation ground support
equipment, such as pumps, lights, and lift platforms.
MILITARY LAND VEHICLES (TRACK AND WHEELED VEHICLES)
Used in military land vehicles to control lights, pumps, arming equipment, and
movement control of lifts/ramps, etc.
CONSTRUCTION EQUIPMENT
Often used on road milling, road pavers, trenchers, and stump cutters to operate
movement of machinery and/or turn on lights, pumps, etc.
Potential Applications
5
sensing.honeywell.com
MICRO SWITCH™ Military-Grade Toggle Switches
Table 1. Specifications
Characteristic Parameter
Description military-grade toggle switch
Sealing qualified to MIL-DTL-3950
Operating temperature -65 °C to 71 °C [-85 °F to 160 °F]
Actuators standard, locking, special design, tab
Action 2- or 3- position; momentary and maintained
Mounting Bushing 15/32 in (0.47 in) Ø
Circuitry SPST, SPDT, DPST, DPDT, 4PST, 4PDT
Terminations IWTS, solder, screw, quick-connect, leadwire
Contacts Silver alloy or gold-plated
Amp rating Up to 20 A, ac and dc capability
Approvals UL, CSA, CE
Measurement 26,7 mm H x 33,5 mm W x 22,6 mm D [1.05 in H x 1.32 in W x 0.89 in D]
Table 2. UL and CSA Electrical Ratings
Rating code Electrical rating
L192 10 amps, 125, 250, 277 Vac; ¼ Hp, 125 Vac; ½ Hp, 250, 277 Vac; 3 amps, 125 Vac “L”
L191 15 amps, 125, 250, 277 Vac; ½ Hp, 125 Vac; 1 Hp, 250, 277 Vac; 5 amps, 125 Vac “L”
Table 3. Electrical Ratings (in amperes)
Electrical rating code 28 Vdc 115 Vdc 250 Vdc 115 Vac, 60 Hz & 400 Hz
Max. 230 Vac
Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res.
115 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
315 20 7 0.75 0.5 15 15 4 6
410 18 5 0.75 0.5 8 11 2 6
512 20 5 0.75 0.5 15 15 4 6
610 18 4 0.75 0.5 8 11 2 6
6sensing.honeywell.com
TL Series
TERMINAL CIRCUIT IDENTIFICATION
Terminal identications are referred to in the order guides to indi-
cate which circuits are made in each toggle position (i.e., 1-2 refers
to circuit closure through terminals 1 and 2).
One Pole
Two Pole
Four Pole
TERMINALS
In addition to the screw terminal listings in the order guides, IWTS
(Integrated Wire Termination Systems) versions and solder turrent
terminals are available.
IWTS provides a reliable, completely serviceable unit which meets
MIL-DTL-3950 requirements. IWTS improves maintainability since
wiring bundles need not be disturbed. Leads are quickly and easily
assembled or removed with an insert-extract tool.
A unique three-rib (grommet style) elastomer seal protects the lead
connections without potting. There are no exposed metal termi-
nals.
Versions available that will accept No. 16 wire with M39029/1-102
contact pins or No. 20 wire with MS39029/1-101 contact pins.
Connections are resistant to shock, vibration, and high pull-out
force.
SPECIAL CIRCUITRIES
Catalog listings with -10, -50, and -70 sufx numbers, as shown
in the order guides, have special “on-on-on” circuits, as illustrated
below. TLs with -12 sufx are the same as -50 except the keyway
position is maintained, and the center position circuits 2-3 and 4-5
are made. -72 is the same as -50 except that the opposite keyway
position is momentary, and in the center position circuits 2-3 and
4-5 are made.
-10 CIRCUITRY
No of
poles
Keyway Side
Maint. Position
Center Maint.
Position
Opposite
Keyway Maint.
Position
2
4
-50 CIRCUITRY
No of
poles
Keyway Side
Maint. Position
Center Maint.
Position
Opposite
Keyway Maint.
Position
2
4
-70 CIRCUITRY
No of
poles
Keyway Side
Maint. Position
Center Maint.
Position
Opposite
Keyway Maint.
Position
2
4
7
sensing.honeywell.com
MICRO SWITCH™ Military-Grade Toggle Switches
TL (SCREW TERMINAL) 2-POSITION ORDER GUIDE
Circuits Made with Toggle At: Standard Toggle Pull-to-Unlock Toggle
No. of
poles Keyway Position Opposite Keyway
Elect.
Rating
Code
UL Rating
Code
Catalog
Listing
Military
Number
Add
Suffix to
Standard
Toggle
Listing D
Military
Number**
1 OFF 2-3 1 L191 1TL1-2 MS24523-22 D, F, G MS24658-22
OFF* 2-3 2 L192 1TL1-4 MS24523-29 F MS24658-29
1-2* OFF 2 L192 1TL1-6 MS24523-30 F MS24658-30
1-2 2-3 1 L191 1TL1-3 MS24523-23 D, F, G MS24658-23
1-2* 2-3 2 L192 1TL1-8 MS24523-26 F MS24658-26
2 OFF 2-3, 5-6 3 L191 2TL1-2 MS24524-22 D, F, G MS24659-22
OFF* 2-3, 5-6 4 L192 2TL1-4 MS24524-29 F MS24659-29
1-2, 4-5* OFF 4 L192 2TL1-6 MS24524-30 F MS24659-30
1-2, 4-5 2-3, 5-6 3 L191 2TL1-3 MS24524-23 D, F, G MS24659-23
1-2, 4-5* 2-3, 5-6 4 L192 2TL1-8 MS24524-26 F MS24659-26
4 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-2 MS24525-22 D, F, G MS24660-22
OFF* 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-4 MS24525-29 F MS24660-29
1-2, 4-5, 7-8, 10-
11*
OFF 6 L192 4TL1-6 MS24525-30 F MS24660-30
1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-3 MS24525-23 D, F, G MS24660-23
1-2, 4-5*, 7-8,
10-11
2-3, 5-6, 8-9, 11-12 6 L192 4TL1-8 MS24525-26 F MS24660-26
* These positions are momentary. All others are maintained.
** Also add the appropriate sufx to the military number.
D See page 12 for locking congurations.
PULL-TO-UNLOCK OPTION
When ordering pull-to-unlock toggle listings (see page 12 for configurations), add the suffix letter shown in the chart on page XXX to the standard tog-
gle listing or the MS part number. For example, to order a 1TL1-1 pull-to-unlock toggle switch with the lever locked in the center position,
add the letter E (i.e., 1TL1-1E, MS24658-21E)
SOLDER TURRET TERMINAL VERSION
11TL, 12TL, and 14TL type switches with solder turrent terminals are quali-
ed to MIL-DTL-3950. They have the same circuitry and electrical ratings as
their 1TL, 2TL, and 4TL counterparts, For example, an 11TL1-2 is the same
as a 1TL1-2, except it has solder turret terminals instead of screw terminals.
Circuitry Type Standard Lever Lever Lock
One pole 11TL MS27734 MS27737
Two pole 12TL MS27735 MS27738
Four pole 14TL MS27736 MS27739
8sensing.honeywell.com
TL Series
TL (SCREW TERMINAL) 3-POSITION ORDER GUIDE
Circuits Made with Toggle At: Standard Toggle Pull-to-Unlock Toggle
No. of
poles Keyway Position Center Position Opposite Keyway
Elect. Rating
Code
UL/CSA
Rating Code
Catalog
Listing
Military
Number
Add
Suffix to
Standard
Toggle
Listing D
Military
Number***
1 1-2 OFF 2-3 1 L191 1TL1-1 MS24523-21 ALL TYPES MS24658-21
1-2* OFF 2-3 2 L192 1TL1-5 MS24523-31 E, F, K, L
M, N
MS24658-31
1-2* OFF 2-3* 2 L192 1TL1-7 MS24523-27 E, L, N MS24658-27
NONE** OFF 2-3 1 L191 1TL1-21 MS24523-24 E, F, K, M MS24658-24
NONE** 1-2 2-3 1 L192 1TL1-31 MS24523-33 E, F, K, M MS24658-33
NONE** 1-2 2-3* 2 L192 1TL1-51 MS24523-32 E MS24658-32
1-2* OFF NONE** 2 L192 1TL1-61 MS24523-28 E MS24658-28
2 1-2, 4-5 OFF 2-3, 5-6 3 L191 2TL1-1 MS24524-21 ALL TYPES MS24659-21
1-2, 4-5* OFF 2-3, 5-6 4 L192 2TL1-5 MS24524-31 E, F, K, L,
M, N
MS24659-31
1-2, 4-5* OFF 2-3, 5-6* 4 L192 2TL1-7 MS24524-27 E, L, N MS24659-27
NONE** OFF 2-3, 5-6 3 L191 2TL1-21 MS24524-24 E, F, K, M MS24659-24
NONE** 1-2, 4-5 2-3, 5-6 3 L191 2TL1-31 MS24524-33 E, F, K, M MS24659-33
NONE** 1-2, 4-5 2-3, 5-6* 4 L192 2TL1-51 MS24524-32 E MS24659-32
1-2, 4-5* OFF NONE** 4 L192 2TL1-61 MS24524-28 E MS24659-28
1-2, 4-5 1-2, 5-6 2-3, 5-6 3 L191 2TL1-10 MS27407-4 ALL TYPES MS27408-4
1-2, 4-5* 1-2, 5-6 2-3, 5-6 4 L192 2TL1-50 MS27407-5 E, F, K, L,
M, N
MS27408-5
1-2, 4-5* 1-2, 5-6 2-3, 5-6* 4 L192 2TL1-70 MS27407-6 E, L, N MS27408-6
4 1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-1 MS24525-21 ALL TYPES MS24660-21
1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-5 MS24525-31 E, F, K, L,
M, N
MS24660-31
1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-7 MS24525-27 E, L, N MS24660-27
NONE** OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-21 MS24525-24 E, F, K, M MS24660-24
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-31 MS24525-33 E, F, K, M MS24660-33
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-51 MS24525-32 E MS24660-32
1-2, 4-5, 7-8, 10-11* OFF NONE** 6 L192 4TL1-61 MS24525-38 E MS24660-28
1-2, 4-5, 7-8, 10-11 2-3, 4-5 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-10 ALL TYPES
1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-50 MS27406-2 E, F, K, L,
M, N
MS27409-2
1-2, 4-5, 7-8, 10-11* 2-3, 4-5 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-70 E, L, N
1-2, 4-5, 7-8, 10-11 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-12 MS27406-1 ALL TYPES MS27409-1
1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-72 MS27406-3 E, L, N MS27409-3
* These positions are momentary. All others are maintained.
** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position.
*** Also add appropriate sufx letter to military number
D See page 12 for locking congurations.
9
sensing.honeywell.com
MICRO SWITCH™ Military-Grade Toggle Switches
TL (IWTS TERMINATION) 2-POSITION ORDER GUIDE
Circuits Made with Toggle At: No. 16 Termination No. 20 Termination
No. of
poles Keyway Position Opposite Keyway
Elect.
Rating
Code
UL Rating
Code
Catalog
Listing
Military
Number
Catalog
Listing
Military
Number
1 OFF 2-3 1 L191 101TL1-2 MS27722-22 101TL2-2 MS27784-22
OFF* 2-3 2 L192 101TL1-4 MS27722-29 101TL2-4 MS27784-29
1-2* OFF 2 L192 101TL1-6 MS27722-30 101TL2-6 MS27784-30
1-2 2-3 1 L191 101TL1-3 MS27722-23 101TL2-3 MS27784-23
1-2* 2-3 2 L192 101TL1-8 MS27722-26 101TL2-8 MS27784-26
2 OFF 2-3, 5-6 3 L191 102TL1-2 MS27723-22 102TL2-2 MS27785-22
OFF* 2-3, 5-6 4 L192 102TL1-4 MS27723-29 102TL2-4 MS27785-29
1-2, 4-5* OFF 4 L192 102TL1-6 MS27723-30 102TL2-6 MS27785-30
1-2, 4-5 2-3, 5-6 3 L191 102TL1-3 MS27723-23 102TL2-3 MS27785-23
1-2, 4-5* 2-3, 5-6 4 L192 102TL1-8 MS27723-26 102TL2-8 MS27785-26
4 OFF 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-2 MS27724-22 104TL2-2 MS27786-22
OFF* 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-4 MS27724-29 104TL2-4 MS27786-29
1-2, 4-5, 7-8, 10-
11*
OFF 6 L192 104TL1-6 MS27724-30 104TL2-6 MS27786-30
1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-3 MS27724-23 104TL2-3 MS27786-23
1-2, 4-5, 7-8, 10-
11*
2-3, 5-6, 8-9, 11-12 6 L192 104TL1-8 MS27724-26 104TL2-8 MS27786-26
TL (IWTS TERMINATION) 3-POSITION ORDER GUIDE
Circuits Made with Toggle At: No. 16 Termination No. 20 Termination
No. of
poles
Keyway Position Center Position Opposite Keyway
Elect. Rating
Code
UL/CSA
Rating Code
Catalog
Listing
Military
Number
Catalog
Listing
Military
Number
1 1-2 OFF 2-3 1 L191 101TL1-1 MS27722-21 101TL2-1 MS27784-21
1-2* OFF 2-3 2 L192 101TL1-5 MS27722-31 101TL2-5 MS27784-31
1-2* OFF 2-3* 2 L192 101TL1-7 MS27722-27 101TL2-7 MS27784-27
2 1-2, 4-5 OFF 2-3, 5-6 3 L191 102TL1-1 MS27723-21 102TL2-1 MS27785-21
1-2, 4-5* OFF 2-3, 5-6 4 L192 102TL1-5 MS27723-31 102TL2-5 MS27785-31
1-2, 4-5* OFF 2-3, 5-6* 4 L192 102TL1-7 MS27723-6 102TL2-7 MS27785-27
4 1-2, 4-5, 7-8,
10-11
OFF 2-3, 5-6, 8-9,
11-12
5 L191 104TL1-1 MS27724-21 104TL2-1 MS27786-21
1-2, 4-5, 7-8,
10-11*
OFF 2-3, 5-6, 8-9,
11-12
6 L192 104TL1-5 MS27724-31 104TL2-5 MS27786-31
1-2, 4-5, 7-8,
10-11*
OFF 2-3, 5-6, 8-9,
11-12*
6 L192 104TL1-7 MS27724-27 104TL2-7 MS27786-27
* These positions are momentary. All others are maintained.
NOTE: For TL switches featuring IWTS termination and a “pull-to-unlock” lever option, contact a Honeywell Sensing and Control representative at
1-800-537-6945.
10 sensing.honeywell.com
TL Series
TL SERIES 1-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS
Note: Three-position switches shown
1TL1: Single pole, standard lever,
screw terminals
11TL1: Single pole, standard lever,
solder terminals
101TL1: Single pole, standard lever,
IWTS terminals
10,9 mm
[0.43 in]
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
31° ±7° total travel
15° 30’ ±3° 30’
Ø 6,09 mm [Ø 0.24 in]
15/32 - 32 UNS 2A thread
to within 1,52 mm
[0.060 in] of shoulder
Sealed to prevent entrance
of liquids or dust
17,0 mm [0.67 in]
11,9 mm
[0.47 in] 6,1 mm [0.24 in]
29,5 mm
[1.16 in]
23,1 mm
[0.91 in]
3X 6-32 UNC-2A X (0.260)
binding head terminal
screw and lockwasher
(sems)
28,4 mm
[1.12 in]
4,8 mm
[0.19 in]
15,7 mm [0.62 in]
19,05 mm
[0.75 in]
9,7 mm
[0.38 in]
10,9 mm
[0.43 in]
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
31° ±7° total travel
15° 30’ ±3° 30’
Ø 6,09 mm [Ø 0.24 in]
15/32 - 32 UNS 2A
thread to within 1,52 mm
[0.060 in] of shoulder
Sealed to prevent
entrance of
liquids or dust
17,0 mm [0.67 in]
11,9 mm
[0.47 in] 6,1 mm [0.24 in]
29,5 mm
[1.16 in]
23,1 mm
[0.91 in]
4,7 mm ± 0,38 mm [0.185 in ±0.015 in] (3)
28,4 mm
[1.12 in]
4,8 mm
[0.19 in]
15,7 mm [0.62 in]
19,05 mm
[0.75 in]
9,7 mm
[0.38 in]
4,57 mm dia [0.18 in dia] (3)
6,4 mm [0.25 in]
2,29 mm dia [0.09 in dia] (3)
10,9 mm
[0.43 in]
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
31° ±7° total travel
15° 30’ ±3° 30’
Ø 6,09 mm [Ø 0.24 in]
15/32 - 32 UNS-2
thr
ead to within 1,52 mm
[0.060 in] of shoulder
Sealed to prevent
entrance of
liquids or dust
17,0 mm [0.67 in]
11,9 mm
[0.47 in] 6,1 mm [0.24 in]
36,07 mm
[1.42 in]
28,4 mm
[1.12 in]
15,7 mm [0.62 in]
9,7 mm
[0.38 in]
28,7 mm ±0,76 mm
[1.130 ±0.030 in]
Sealed construction
(blue seal)
9,7 mm
[0.38 in]
Locking lever dimensions for
single pole TL toggles
26,67 mm
[1.05 in]
Ø 10,67 mm
[Ø 0.42 in]
31° ±7°
total travel
15° ±3°
2,28 mm
[0.090 in]
approx. pullout
to change
position
11
sensing.honeywell.com
MICRO SWITCH™ Military-Grade Toggle Switches
TL SERIES 2-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS
Note: Three-position switches shown
2TL1: Single pole, standard lever,
screw terminals
12TL1: Single pole, standard lever,
solder terminals
102TL1: Single pole, standard lever,
IWTS terminals
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
10,9 mm
[0.43 in]
34° ±8° total travel
Ø 6,09 mm [Ø 0.24 in]
17° ±4°
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS 2A
thread to within
1,52 mm [0.060 in]
of shoulder
17,0 mm [0.67 in]
11,9 mm
[0.47 in] 6,1 mm [0.24 in]
34,29 mm
[1.35 in]
3,3 mm min.
[0.130 in min.]
27,94 mm
[1.10 in]
3,3 mm min.
[0.130 in min.]
6,6 mm
[0.26 in]
22,6 mm
[0.89 in]
9,7 mm
[0.38 in]
33,53 mm
[1.32 in]
19,05 mm
[0.75 in]
9,7 mm
[0.38 in]
7,1 mm
[0.28 in]
6X 6-32
UNC-2A x (0.260)
binding head terminal
screw and lockwsher
(sems)
3
2
1
6
5
4
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
Ø 6,09 mm [Ø 0.24 in]
10,9 mm
[0.43 in]
34° ±8° total travel
6,09 mm [0.24 in]
17° ±4°
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS-2
thread to within
1,52 mm [0.060 in]
of shoulder
17,0 mm [0.67 in]
3,05 mm
[0.12 in]
11,9 mm
[0.47 in]
34,29 mm
[1.35 in]
3,3 mm min.
[0.130 in min.]
27,94 mm
[1.10 in] 3,3 mm min.
[0.130 in min.]
0,76 mm [0.03 in] (6)
4,57 mm dia
[0.18 in dia] (6)
2,29 mm dia [0.09 in dia] (6)
4,83 mm dia [0.19 in dia] (6)
34,0 mm max.
[1.34 in max.]
23,1 mm max.
[0.91 in max]
19,05 mm
[0.75 in]
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
7,1 mm
[0.28 in]
6,6 mm [0.26 in]
3
2
1
6
5
4
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
34° ±8° total travel
6,09 mm [0.24 in]
17° ±4°
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS-2
thread to within
1,52 mm [0.060 in]
of shoulder
17,0 mm [0.67 in]
3,05 mm
[0.12 in]
37,34 mm max
[1.47 in max.]
11,9 mm
[0.47 in]
Terminals accept
PIN M39029/1-102
22,6 mm
[0.89 in]
33,53 mm
[1.320 in]
Sealed construction
(blue seal)
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
Ø 6,09 mm [Ø 0.24 in]
10,9 mm
[0.43 in]
Locking lever dimensions for
double pole TL toggles
26,67 mm
[1.05 in]
Ø 10,67 mm
[Ø 0.42 in]
34° ±8°
total travel
17° ±4°
2,28 mm
[0.090 in]
approx. pullout
to change
position
12 sensing.honeywell.com
TL Series
TL SERIES 4-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS
Note: Three-position switches shown
4TL1: Four-pole, standard lever,
screw terminals
14TL1: Four-pole, standard lever,
solder terminals
104TL1: Four pole, standard lever,
IWTS terminals
1,93 mm ±0,20 mm
wide keyway
[0.076 in ±0.008
wide keyway]
10,9 mm
[0.43 in]
34° ±8° total travel
17° ±4°
10,9 mm
[0.43 in]
Ø 6,09 mm [Ø 0.24 in]
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS 2A
thread to within
1,52 mm [0.060 in]
of shoulder
3,05 mm
[0.12 in]
11,9 mm
[0.47 in]
17,01 mm
[0.67 in]
27,94 mm
[1.10 in] 3,3 mm min.
[0.130 in min.]
6,1 mm [0.24 in]
34,29 mm
[1.35 in]
6,6 mm
[0.26 in]
41,66 mm
[1.64 in] 9,4 mm
[0.37 in]
33,53 mm
[1.32 in]
19,05 mm
[0.75 in]
9,7 mm
[0.38 in]
7,1 mm [0.28 in]
9,4 mm
[0.37 in]
9,4 mm
[0.37 in]
6,4 mm [0.25 in]
3,3 mm min. [0.130 in min.]
12X 6-32 UNC-2 X
(0.260) binding head
terminal screw and
lockwasher (sems)
3
2
1
9
8
7
6
5
4
12
11
10
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS-2
thread to within
1,52 mm [0.060 in]
of shoulder
3,3 mm min.
[0.130 in min.]
0,76 mm [0.03 in] (12)
4,57 mm dia [0.18 in dia] (12)
2,29 mm dia [0.09 in dia] (12)
4,83 mm dia [0.19 in dia] (12)
33,53 mm
[1.32 in]
41,7 mm
[1.64 in]
19,05 mm
[0.75 in]
9,4 mm
[0.37 in]
9,7 mm
[0.38 in]
7,1 mm
[0.28 in]
6,6 mm
[0.26 in]
9,4 mm
[0.37 in]
9,4 mm
[0.37 in]
6,09 mm [0.24 in]
17,0 mm [0.67 in]
11,9 mm [0.47 in]
34,29 mm
[1.35 in]
27,94 mm
[1.10 in] 3,3 mm min.
[0.130 in min.]
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
Ø 6,09 mm [Ø 0.24 in]
10,9 mm
[0.43 in]
34° ±8° total travel
17° ±4°
3,05 mm
[0.12 in]
3
2
58
1
6
4
9
7
12
10
11
1,93 mm ±0,20 mm wide keyway
[0.076 in ±0.008 wide keyway]
Ø 6,09 mm [Ø 0.24 in]
10,9 mm
[0.43 in]
34° ±8° total travel
17° ±4°
3,05 mm
[0.12 in]
Sealed to prevent
entrance of
liquids or dust
15/32 - 32 UNS-2
thread to within
1,52 mm [0.060 in]
of shoulder
6,09 mm [0.24 in]
17,0 mm [0.67 in]
11,9 mm [0.47 in]
37,3 mm
[1.47 in]
Terminals accept
PIN M39029/1-102
33,53 mm
[1.320 in]
Sealed construction
(blue seal)
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
9,7 mm
[0.38 in]
41,7 mm
[1.64 in]
Locking lever dimensions for
four-pole NT toggles
26,67 mm
[1.05 in]
Ø 10,67 mm
[Ø 0.42 in]
34° ±8°
total travel
17° ±4°
2,28 mm
[0.090 in]
approx. pullout
to change
position
13
sensing.honeywell.com
MICRO SWITCH™ Military-Grade Toggle Switches
MICRO SWITCH TL™ SERIES LOCKING CONFIGURATIONS
005430-3-EN | 3 | 10/17
Copyright © 2017 Honeywell International Inc. All rights reserved.
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com
For more information
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specications, pricing or the near-
est Authorized Distributor, visit sensing.
honeywell.com or call:
Asia Pacic +65 6355-2828
Europe +44 (0) 1698 481481
USA/Canada +1-800-537-6945
ADDITIONAL INFORMATION
The following associated literature is available on the Web
(sensing.honeywell.com):
Product installation instructions
Product range guide
Product application-specific information
Flight deck toggle switches
Sensors and switches in front loaders
Sensors and switches in mobile cranes
Sensors and switches in oil rig applications
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particu-
lar purpose. In no event shall Honeywell be liable for conse-
quential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
102TL2-12A 102TL2-3 12TL1-1A 12TL1-2 101TL2-2F 101TL255-3 101TL2887-51 101TL2887-8F 102TL1-2D
102TL1-6 102TL200-1 102TL2-10E 102TL2-10M 102TL2-10P 102TL2133-10 102TL2-50N 102TL2-72L
102TL2855-7 104TL2-7 104TL2-72 104TL286-12A 104TL2887-3 104TL2887-8F 11TL146-2 1TL119-3-A03
1TL119-4-A02 1TL133-21 1TL150-7E 1TL28-5 1TL28-7 1TL5-1 1TL5-3 1TL5-7 1TL64-51 1TL82-7 1TL887-51E
2TL124-10 2TL126-70-A02 2TL130-21 2TL149-1A 2TL256-5F 2TL28-1 2TL49-3G 2TL57-7 2TL84-7R 2TL863-7
2TL887-3D 2TL887-7E 4TL11-82G 4TL143-3D 4TL887-51E 1TL11-1 1TL11-5 1TL11-7 1TL11-8 1TL11-82
1TL91-3 1TL91-4 1TL91-7 2TL1-1L 2TL1-50 2TL150-1N 2TL150-3D 2TL1-50E 2TL1-50F 2TL1-50K 2TL1-50M
2TL1-50N 2TL49-1A 2TL49-21E 2TL49-31E 2TL51-5 2TL887-3 2TL91-8 4TL1-10A 4TL1-10E 4TL1-10L 4TL1-
10M 4TL1-10P 4TL1-1D 4TL1-1E 4TL1-1L 4TL1-1M 4TL1-1N 4TL1-1P 4TL1-21F 4TL1-21K 4TL1-2D 4TL1-2F
4TL1-2G 4TL1-31K 4TL1-3F 4TL1-3G 4TL1-50 4TL150-3D 4TL1-50E 4TL1-50F 4TL1-50K 4TL1-50L 4TL1-50M