LH2H LH2H Hour Meters DIN HALF SIZE HOUR METER Features 5. Battery Replacement Easy on Environment To replace battery simply remove body for the one-touch installation type, and remove battery lid for the installation frame type. 6. Screw Terminals Designed for Safety Built in finger protection. 7. Panel Covers Replacable (Standard color is ash gray.) Change the panel design by replacing with a black panel cover. 8. Conforms to IP66 Protective Construction (Only installation frame type.) (Front panel surface) 9. Input Methods 1) Non-voltage input method 2) Voltage input method 3) Free voltage input method 10. Backlight Type Added to Series and Now 2-color Switchable (green/ red) Easy viewing even in dark places and switchable between green and red (Voltage input type). 11. Compliant with UL, c-UL and CE marking. 1. 8.7 mm Character Height (previously 7 mm .343 inch) Easy-to-read character height increased from 7 mm to 8.7 mm .276 inch to .343 inch. Panel mounting type One-touch installation type 8.7mm .343inch 2. Plenty of Digits 7 digits Panel mounting type Installation frame type 3. Select by switch between two time ranges in a single meter. 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable 4. Panel Mounting Type Features 2 Installation Methods Comes with very easy one-touch installation type and also installation frame type that uses the frame on the timer/counter. Choose a method that suits the application. PC board mounting type RoHS Directive compatibility information http://www.nais-e.com/ Product chart Type Installation type Panel mounting type Non-voltage input type Standard type Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Backlight type Voltage input type (4.5 to 30 V DC) One-touch installation type Installation frame type -- -- -- PC board mounting type Product types 1. Panel mounting type 1) One-touch installation type 1 Standard type No. digits 7 digits Measurement time range 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable Front reset Input method Non-voltage input type Yes Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. Part No. LH2H-FE-DHK LH2H-FE-HMK LH2H-FE-DHK-DL LH2H-FE-HMK-DL LH2H-FE-DHK-FV LH2H-FE-HMK-FV LH2H 2 Backlight type No. digits 7 digits Measurement time range 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable Front reset Yes Input method Voltage input type (4.5 to 30 V DC) Part No. LH2H-FE-DHK-DL-B LH2H-FE-HMK-DL-B 2) Installation frame type 1 Standard type No. digits 7 digits Measurement time range 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable Front reset Input method Non-voltage input type Yes Voltage input type (4.5 to 30 V DC) Free voltage input type (24 to 240 V AC/DC) Part No. LH2H-F-DHK LH2H-F-HMK LH2H-F-DHK-DL LH2H-F-HMK-DL LH2H-F-DHK-FV LH2H-F-HMK-FV 2 Backlight type No. digits 7 digits Measurement time range 0 to 999999.9h/0 to 3999d23.9h switchable 0 to 999h59m59s/0 to 9999h59.9m switchable Front reset Yes Input method Voltage input type (4.5 to 30 V DC) Part No. LH2H-F-DHK-DL-B LH2H-F-HMK-DL-B 2. PC board mounting type No. digits 7 digits Measurement time range 0 to 999999.9h 0 to 9999h59.9m Front reset No Input method Non-voltage input type Part No. LH2H-C-H-N LH2H-C-HM-N Specifications 1. Panel mounting type Type Item No. digits External power supply Measurement time range Min. input signal width Input method (signal) Start input Input impedance Residual voltage Min. input signal width Input method (signal) Reset input Input impedance Residual voltage Display method Breakdown voltage (initial) Insulation resistance (initial) Backlight power Protective construction (Note) Accessories (Note) Battery life Standard type Non-voltage input Backlight type Standard type Voltage input Free voltage type 7 digits Not required (built-in battery) 0 to 999999.9h/0 to 3999d23.9h (Switchable by switch) 0 to 999h59m59s/0 to 9999h59.9m (Switchable by switch) Separate product type 200 ms High level: Non-voltage input using High level: 4.5 to 30 V DC 24 to 240 V AC/DC contacts or open collector Low level: 0 to 2 V DC Low level: connection 0 to 2.4 V AC/DC When shorted: Max. 10 k Approx. 4.7 k -- When open: Max. 750 k Max. 0.5 V -- -- 100 ms Non-voltage input using Non-voltage input using High level: 4.5 to 30 V DC contacts or open collector contacts or open collector Low level: 0 to 2 V DC connection connection When shorted: When shorted: Max. 10 k Max. 10 k Appox. 4.7 k When open: When open: Max. 750 k Max. 750 k Max 0.5 V -- Max. 0.5 V 7-segment LCD 7-segment LCD 7-segment LCD With green/red backlight Between charged and Between charged and uncharged parts: 1,000 V AC for 1 minute. uncharged parts: 2,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. -- 24 V DC (10%) -- IEC Standard IP66 (only panel front: when using rubber gasket) Rubber gasket, mounting bracket 10 years (at 25C 77F) Note) Only for installation frame type. All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LH2H 2. PC board mounting type Type Item Input method No. digits Rated operation voltage Allowable operation voltage range Current consumption Measurement time range Min. input signal width Input method Start input Input impedance Reset input Residual voltage Min. input signal width Input method Input impedance Residual power Break down voltage (initial) Insulation resistance (initial) PC board mounting type Non DC voltage input 7 digits 3 V DC 2.7 to 3.3 V DC Max. 20 A (max. 200 A during reset input) 0 to 999999.9h 0 to 9999h59.9m 200 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V 10 ms Non-voltage input using contacts or open collector connection When shorted: Max. 10 k When open: Max. 750 k Max. 0.5 V Between charged and uncharged parts: 1,000 V AC for 1 minute. Min. 100 M (measured at 500 V DC) Measurement location same as for break down voltage. 3. Common Type Panel mounting/PC board mounting types Item Time accuracy 100 ppm (25C 77F) 10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm (10 min. on 3 axes) 10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm (1 hr. on 3 axes) Min. 98 m/s2 (4 times on 3 axes) Min. 294 m/s2 (5 times on 3 axes) -10 to +55C +14 to +131F (without frost or dew) -25 to +65C -13 to +149F (without frost or dew) 35 to 85% RH (non-condensing) Functional Vibration resistance Destructive Functional Shock resistance Destructive Operation temperature Storage temperature Ambient humidity Applicable standard Safety standard EN61010-1 (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity Pollution Degree 2/Overvoltage Category III EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 EMC RF electromagnetic field immunity EN61000-4-3 EFT/B immunity Conductivity noise immunity Power frequency magnetic field immunity EN61000-4-4 EN61000-4-6 EN61000-4-8 4 kV contact 8 kV air 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (90 MHz) 2 kV (power supply line) 10 V/m AM modulation (0.15 MHz to 80 MHz) 30 A/m (50 Hz) All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LH2H Part names 1. Front reset button Reset the elapsed time. It does not work when the lock switch is ON. Be aware that battery life will decrease if this switch is used frequently. 2. Lock switch (Refer to chart on right.) Disable the front reset button. HOUR METER h RESET m Time range switch s LH2H Front reset button Time unit seal Lock switch Note) Turn ON at the LCD side (reset disabled) and OFF at the terminal block side (reset enabled). 3. Time range switch (See chart on right). Switch the time range. 0 to 999999.9h/0 to 3999d23.9h Note) Always press the front reset button when operating the time range switch. 4. Time unit sticker Unit seals are included in the package. Affix them in accordance with the time range. 0 to 999h59m59s/0 to 9999h59.9m (Terminal block side) OFF (LCD side) ON Lock switch (Unit display 1) (Terminal block side) 0 to 999999.9h (Terminal block side) 0 to 9999h59.9m 0 to 3999d23.9h 0 to 999h59m59s Count speed switch (Unit display 2) (LCD side) (LCD side) Notes) 1. Default setting when shipped. 2. Make the switch setting before installing to panel. Dimensions mm inch General tolerance: 1.0 .039 1. Panel mounting type * External dimensions 1) One-touch installation type * Panel installation diagram 44.8 1.764 M3.5 M.138 Panel (1 to 4.5mm .039 to .177inch thickness) 54.4 2.142 Rubber spacer Note) When installing to a 4.5 mm .177 inch thick panel, remove the rubber spacer first. 10.4 .409 (44) (1.732) 5 .197 48 1.890 HOUR METER 22 .866 24 .945 RESET LH2H 7 .276 Reset button When installing the one-touch installation type model, make sure that the installation spring does not pinch the rubber gasket. To prevent the installation spring from pinching the rubber gasket: 1. Set the rubber gasket on both ends of the installation spring (left and right). 2. Confirm that the installation spring is not pinching the rubber gasket, and then insert and fix the installation spring in place from the rear of the timer unit. All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LH2H 2) Installation frame type * Panel mounting diagram 44.8 1.764 Mounting frame ATH3803 (included) Mounting screws (found on mounting bracket) M3.5 M.138 54.4 2.142 37 1.457 Rubber gasket ATH3804 (included) Panel (1 to 4.5mm .039 to .177inch thickness) 10.4 .409 44 1.732 48 1.890 5 .197 HOUR METER 22 .866 24 .945 RESET LH2H 7 .276 Reset button * Panel cut-out dimensions * For connected installation (sealed installation) (Only installation frame type.) The standard panel cut-out is shown below. Use the mounting frame (ATH3803) and the rubber packing (ATH3804). (Only installation frame type.) 22.2+0.5 0 .874+.020 0 A A=(48xn-2.5)+1.0 0 A=(1.890xn-.098)+.039 0 60 min. 2.362 min. 45+0.5 0 1.772+.020 0 Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm .039 to .177 inch. 2. Waterproofing will be lost when installing repeatedly (sealed installation). +0.5 0 +.020 0 22.2 .874 * Terminal layout and wiring diagrams 1) Standard type Non voltage input type Start input Voltage input type Start input +V Reset input 1 2 3 1 4 Free voltage input type Reset input +V 2 3 4 Start input or 0V 0V W-R are connected internally. 2) Backlight type Voltage input type Start input +V Reset input +V 0V +V 5 1 2 5 3 4 1 6 0V Backlight 2 5 3 4 1 6 2 3 4 6 0V 0V +V All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. Reset input 1 2 3 4 LH2H General tolerance: 1.0 .039 mm inch 2. PC board mounting type * External dimensions PC board pattern (BOTTOM VIEW) 33.020.3 1.300.012 5.080.3 .200.012 0.60.1 .024.004 5.080.3 .200.012 Mounting area 2.54 .100 DIP switch x 8 1.9 .075 2.54 .100 3.30.3 .130.012 15.24 Connection sockets .600 28 pin DIP terminal 8-0.8 dia. 8-.031 dia. 43.4 1.709 0.50.3 .020.012 17.3 .681 5.19 .204 15.240.3 .600.012 19 .748 1.9 5.19 .075 .204 5.08 .200 5.08 .200 33.02 1.300 HOUR METER LH2H General tolerance: 0.1 .004 0.30.1 .012.004 Note: The AXS212811K is recommended as a compatible connection socket. * Terminal layout and wiring diagrams Start input 15 17 26 28 14 12 3 Reset input 1 Q-E, }-w, e-t and S-F are connected internally. An external power supply is required. Input method 1. Standard type Non-voltage input type Panel mounting type Contact input Start input 1 2 3 4 PC board mounting type Transistor input Contact input NPN transistor Transistor input NPN transistor Reset input Start input 1 2 3 Reset input 4 0V (W and R are connected internally.) Start input 15 17 26 28 14 12 3 1 Reset input Start input 15 17 26 28 14 12 3 1 Reset input 0V (W and R are connected internally.) 3V DC 3V DC Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type, please use relays and switches with high contact reliability. 2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 A) Voltage input type Transistor input +V Start input Reset input 1 2 3 4 +V Start input 1 2 3 4 Free voltage input type PNP transistor +V +V Reset input Start input 1 2 3 4 Reset input 1 or or 2 3 4 or Reset input NPN transistor Start input Contact input Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.) 2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 A) 3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LH2H 2. Backlight type Voltage input type Transistor input Contact input NPN transistor +V Start input Reset input 5 1 2 3 Backlight connection PNP transistor +V +V Green +V Red 24V DC Start input 1 2 3 Reset input 4 Start input 4 6 5 1 2 3 4 6 Reset input 5 1 2 6 5 3 4 1 2 6 3 4 24V DC Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight. 2. 2 and 4. (The input and reset circuits are functionally insulated.) 3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 A) 4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. Explanation of operation 1. Time measuring takes place when the start input is ON. 2. When the elapsed (measured) time reaches full scale it returns to "0", and then measuring starts again from "0". 3. When reset input is ON, the display becomes "0". You cannot measure during reset input. For PC board mounting type the display disappears while the reset input is ON; however, the display reads "0" when the reset input turns OFF. 4. Press the front reset button if you want to perform a manual reset (for panel installation type) ON Start input ON OFF ON Reset input OFF Full scale PC board type Elapsed time 0 All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LH2H Cautions for use 1. Non-voltage input type For both panel mounting and PC board mounting types 1) Never apply voltage to the non-voltage input type. This will damage the internal elements. 2) Since the current flow is very small from the start input and reset input terminals (1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board mounting type) please use relays and switches with high contact reliability. When inputting with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. 3) When wiring, try to keep all the input lines to the start and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 mm2). In particular, when using shielded wiring, be careful of the capacitance between wires. PC board mounting type 1) For external power supply use manganese dioxide or lithium batteries (CR type: 3V). 2) Always reset after external power is applied and confirm that the display reads "0". 3) Make the wiring from the battery to the hour meter unit as short as absolutely possible. Also, be careful of polarity. 4) Calculate battery life with the following formula. t = A/I t: battery life [h] I: LH2H current consumption [mA] A: battery capacity until minimum operation voltage is reached [mAh] 5) Hand solder to the lead terminal. Do not dip solder. With the tip of the soldering iron at 300C 572F perform soldering within 3 seconds (for 30 to 60 W soldering iron). 2. Voltage input type 1) Be aware that applying more than 30 V DC to start input terminals 1 and 2, and reset input terminals 3 and 4 will cause damage to the internal elements. 2) For external resetting use H level (application of 4.5 to 30 V DC) between reset terminals 3 and 4 of the rear terminals. In this case, connect + to terminal 3 and - to terminal 4. This is the valid polarity; therefore, the hour meter will not work if reversed. 3) When wiring, try to keep all the input lines to the start and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft. for parallel wires of 2 mm2). 3. Free voltage input type 1) Use start input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non-voltage input. 2) Be aware that the application of voltage that exceeds the voltage range of the H level to the start input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. 3) Since the current flow is very small from reset input terminal 3, please use relays and switches with high contact reliability. 4) When inputting a reset with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. 5) To reset externally, short reset input terminals 3 and 4 on the rear. 6) Input uses a high impedance circuit; therefore, erroneous operation may occur if the influence of induction voltage is present. If you plan to use wiring for the input signal that is 10 m or longer (wire capacitance 120 pF/m at normal temperature), we recommend the use of a CR filter or the connection of a bleeder resistor. 4. How to reset multiple panel mounting type counters all at once (input is the same for count) Non-voltage input type D D 3 4 D 3 4 Tr 5. Backlight luminance To prevent varying luminance among backlights when using multiple Backlight types, please use the same backlight power supply. 24V DC Voltage input type 3 4 3 4 3 4 +V +V or 2 5 2 2 6 6 24V DC Red 6. Acquisition of CE marking Please abide by the conditions below when using in applications that comply with EN 61010-1/IEC 61010-1 1) Ambient conditions * Overvoltage category II, pollution level 2 * Indoor use * Acceptable temperature and humidity range: -10 to +55C, 35 to 85%RH (with no condensation at 20C) * Under 2000 m elevation 2) Use the main unit in a location that matches the following conditions. * There is minimal dust and no corrosive gas. * There is no combustible or explosive gas. * There is no mechanical vibration or impacts. * There is no exposure to direct sunlight. * Located away from large-volume electromagnetic switches and power lines with large electrical currents. 3) Connect a breaker that conforms to EN60947-1 or EN60947-3 to the voltage input section. 4) Applied voltage should be protected with an overcurrent protection device (example: T 1A, 250 V AC time lag fuse) that conforms to the EN/IEC standards. (Free voltage input type) 7. Terminal connection Tighten the terminal screws with a torque of 0.8 N*cm or less. Notes) 1. Use the following as a guide for choosing transistors used for input (Tr). Leakage current < 1 A 2. Use as small a diode (D) as possible in the forward voltage so that the voltage between terminals 3 and 4 during reset input meets the standard value (0.5 V). ( At IF = 20 A, forward voltage 0.1 and higher.) R Tr 5 Green or 3 4 2 3 4 Note) Make sure that H (reset ON) level is at least 4.5 V. All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.