https://www.phoenixcontact.com/us/products/2906233 Current transformer - PACT RCP-4000A-UIRO-D190 - 2906233 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines. The signal conditioner outputs 8 different standard signals on the output side and has one switching output. Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626048260 Weight per Piece (excluding packing) 440.000 g Custom tariff number 85437090 Country of origin Germany Technical data Measuring transducer supply Nominal supply voltage 24 V DC Nominal supply voltage range 9.6 V DC ... 30 V DC Power consumption 1 W (at IOUT = 20 mA, 9.6 V DC, 600 load) Measuring coil input data Frequency measuring range 40 Hz ... 20000 Hz Position error <1% Linearity error 0.1 % Measuring transducer input data Measuring ranges (current) 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A Configurable/programmable Via DIP switches 04/13/2017 Page 1 / 5 https://www.phoenixcontact.com/us/products/2906233 Current transformer - PACT RCP-4000A-UIRO-D190 - 2906233 Technical data Measuring transducer signal input Input signal (at 50 Hz) 100 mV (1000 A) Input impedance > 100 k Measuring coil signal output Output signal (at 50 Hz) 100 mV (no load, at 1,000 A) Output voltage (in no-load operation) VOUT = M * dI/dt Output voltage (sinusoidal, in no-load operation) 100 mV (VOUT = 2 * * M * f * I (M = 0.318 H; example: At 50 Hz; I = 1,000 A)) Measuring transducer signal output Current output signal 0 mA ... 20 mA (via DIP switch) 4 mA ... 20 mA (via DIP switch) 0 mA ... 10 mA (via DIP switch) 2 mA ... 10 mA (via DIP switch) 0 mA ... 21 mA (Can be set via software) Voltage output signal 0 V ... 10 V (via DIP switch) 2 V ... 10 V (via DIP switch) 0 V ... 5 V (via DIP switch) 1 V ... 5 V (via DIP switch) 0 V ... 10.5 V (Can be set via software) Load/output load current output 600 (20 mA) General data, measuring coil Length of measuring coil 600 mm Diameter of measuring coil 8.3 mm 0.2 mm Length of signal cable 3000 mm Conductor structure signal line 2x 0.22 mm (Signal (tinned)) 1x 0.22 mm (Shielding (tinned)) Coil material Elastollan Housing material PC Insulation double insulation Rated insulation voltage 1000 V AC (rms CAT III) 600 V AC (rms CAT IV) Test voltage 10.45 kV (DC / 1 min.) Basic accuracy < 0.21 % UL, USA/Canada UL 61010 Recognized General data for measuring transducer Maximum transmission error 0.5 % (From the range end value) Frequency range 16 Hz ... 1000 Hz 04/13/2017 Page 2 / 5 https://www.phoenixcontact.com/us/products/2906233 Current transformer - PACT RCP-4000A-UIRO-D190 - 2906233 Technical data General data for measuring transducer Housing material PBT Degree of protection IP20 Test voltage 3 kV (50 Hz, 1 min.) UL, USA/Canada UL 508 Listed General data Standards/regulations IEC 61010-1 IEC 61010-2-032 Degree of pollution 2 Overvoltage category II Typical measuring error <1% Connection data Connection name Measuring transducer side Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 1.5 mm Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section AWG min. 26 Conductor cross section AWG max. 16 Screw thread M3 Connection method Screw connection Stripping length 10 mm Torque 0.5 Nm ... 0.6 Nm Dimensions Width 6.20 mm Height 110.50 mm Depth 120.50 mm Ambient conditions Ambient temperature (operation) -30 C ... 80 C (Measuring coil) -40 C ... 70 C (Measuring transducer) Ambient temperature (storage/transport) -40 C ... 80 C (Measuring coil) -40 C ... 85 C (Measuring transducer) Maximum altitude > 4000 m Measuring coil degree of protection IP67 (not assessed by UL) Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC 04/13/2017 Page 3 / 5 https://www.phoenixcontact.com/us/products/2906233 Current transformer - PACT RCP-4000A-UIRO-D190 - 2906233 Technical data Standards and Regulations Noise emission EN 61000-6-4 Standards/regulations IEC 61010-1 IEC 61010-2-032 Rated insulation voltage 300 V Degree of pollution 2 Overvoltage category II Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Conformance CE-compliant Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram OUT IN Sensor / Field PLC / DCS S-Port + IN + Coil output - 2 TI+ 5 + OUT U, I+ active + 1 1 - 2 - 4 passive 6 - OUT U, I- IN - + 3 5 RO+ PWR+ RO- 6 7 + PWR- 8 - PWR- PWR+ FM Classifications eCl@ss eCl@ss 4.0 27210902 eCl@ss 4.1 27210902 eCl@ss 5.0 27210902 eCl@ss 5.1 27210902 eCl@ss 6.0 27210902 eCl@ss 7.0 27210902 eCl@ss 8.0 27210902 eCl@ss 9.0 27210902 04/13/2017 Page 4 / 5 https://www.phoenixcontact.com/us/products/2906233 Current transformer - PACT RCP-4000A-UIRO-D190 - 2906233 Classifications ETIM ETIM 3.0 EC002048 ETIM 4.0 EC002048 ETIM 5.0 EC002048 ETIM 6.0 EC002048 UNSPSC UNSPSC 13.2 39121032 Accessories Accessories Mounting material Holder - PACT RCP-CLAMP - 2904895 The optional holding device ensures the Rogowski coil is securely seated on busbars with a thickness of 10 ... 15 mm. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically. Holder - PACT RCP-CLAMP-5-10 - 2907888 The optional holding device ensures the Rogowski coil is securely seated on busbars that are 5 ... 10 mm thick. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically. Phoenix Contact 2017 (c) - all rights reserved http://www.phoenixcontact.com 04/13/2017 Page 5 / 5