https://www.phoenixcontact.com/us/products/2906233
04/13/2017Page1/5
Current transformer-PACT RCP-4000A-UIRO-D190-2906233
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 600 mm in
length/190 mm in diameter for AC current measurement on busbars and power lines.
The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4055626048260
Weight per Piece (excluding packing) 440.000 g
Custom tariff number 85437090
Country of origin Germany
Technical data
Measuring transducer supply
Nominal supply voltage 24 V DC
Nominal supply voltage range 9.6 V DC ... 30 V DC
Power consumption ≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
Measuring coil input data
Frequency measuring range 40 Hz ... 20000 Hz
Position error < 1 %
Linearity error 0.1 %
Measuring transducer input data
Measuring ranges (current) 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Configurable/programmable Via DIP switches
https://www.phoenixcontact.com/us/products/2906233
04/13/2017Page2/5
Current transformer-PACT RCP-4000A-UIRO-D190-2906233
Technical data
Measuring transducer signal input
Input signal (at 50 Hz) 100 mV (1000 A)
Input impedance > 100 kΩ
Measuring coil signal output
Output signal (at 50 Hz) 100 mV (no load, at 1,000 A)
Output voltage (in no-load operation) VOUT = M * dI/dt
Output voltage (sinusoidal, in no-load operation) 100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I =
1,000 A))
Measuring transducer signal output
Current output signal 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
0 mA ... 10 mA (via DIP switch)
2 mA ... 10 mA (via DIP switch)
0 mA ... 21 mA (Can be set via software)
Voltage output signal 0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10.5 V (Can be set via software)
Load/output load current output ≤ 600 Ω (20 mA)
General data, measuring coil
Length of measuring coil 600 mm
Diameter of measuring coil 8.3 mm ±0.2 mm
Length of signal cable 3000 mm
Conductor structure signal line 2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielding (tinned))
Coil material Elastollan
Housing material PC
Insulation double insulation
Rated insulation voltage 1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage 10.45 kV (DC / 1 min.)
Basic accuracy <± 0.21 %
UL, USA/Canada UL 61010 Recognized
General data for measuring transducer
Maximum transmission error ≤ 0.5 % (From the range end value)
Frequency range 16 Hz ... 1000 Hz
https://www.phoenixcontact.com/us/products/2906233
04/13/2017Page3/5
Current transformer-PACT RCP-4000A-UIRO-D190-2906233
Technical data
General data for measuring transducer
Housing material PBT
Degree of protection IP20
Test voltage 3 kV (50 Hz, 1 min.)
UL, USA/Canada UL 508 Listed
General data
Standards/regulations IEC61010-1
IEC61010-2-032
Degree of pollution 2
Overvoltage category II
Typical measuring error < 1 %
Connection data
Connection name Measuring transducer side
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 16
Screw thread M3
Connection method Screw connection
Stripping length 10 mm
Torque 0.5 Nm ... 0.6 Nm
Dimensions
Width 6.20 mm
Height 110.50 mm
Depth 120.50 mm
Ambient conditions
Ambient temperature (operation) -30 °C ... 80 °C (Measuring coil)
-40 °C ... 70 °C (Measuring transducer)
Ambient temperature (storage/transport) -40 °C ... 80 °C (Measuring coil)
-40 °C ... 85 °C (Measuring transducer)
Maximum altitude > 4000 m
Measuring coil degree of protection IP67 (not assessed by UL)
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
https://www.phoenixcontact.com/us/products/2906233
04/13/2017Page4/5
Current transformer-PACT RCP-4000A-UIRO-D190-2906233
Technical data
Standards and Regulations
Noise emission EN 61000-6-4
Standards/regulations IEC61010-1
IEC61010-2-032
Rated insulation voltage 300 V
Degree of pollution 2
Overvoltage category II
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Conformance CE-compliant
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Block diagram
IN OUT
passive
5
6
Sensor / Field PLC / DCS
PWR+
PWR–
+
+
+
+
FM
1 5
2
3 7
4 8
OUT U, I–
PWR–
IN +
IN
RO–
OUT U, I+
TI+
PWR+RO+
6
S-Port
active
1
2
+
Coil output
Classifications
eCl@ss
eCl@ss 4.0 27210902
eCl@ss 4.1 27210902
eCl@ss 5.0 27210902
eCl@ss 5.1 27210902
eCl@ss 6.0 27210902
eCl@ss 7.0 27210902
eCl@ss 8.0 27210902
eCl@ss 9.0 27210902
https://www.phoenixcontact.com/us/products/2906233
04/13/2017Page5/5
Current transformer-PACT RCP-4000A-UIRO-D190-2906233
Classifications
ETIM
ETIM 3.0 EC002048
ETIM 4.0 EC002048
ETIM 5.0 EC002048
ETIM 6.0 EC002048
UNSPSC
UNSPSC 13.2 39121032
Accessories
Accessories
Mounting material
Holder-PACT RCP-CLAMP-2904895
The optional holding device ensures the Rogowski coil is securely seated on busbars with a thickness of 10 ... 15 mm.
During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Holder-PACT RCP-CLAMP-5-10-2907888
The optional holding device ensures the Rogowski coil is securely seated on busbars that are 5 ... 10 mm thick. During
installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Phoenix Contact 2017 © - all rights reserved
http://www.phoenixcontact.com