Inductive sensors IWRM 08 Inductive linear sensors sample drawing 46 SW 13 34 M8 x 1 M8 x 1 general data sample picture mounting type quasi shielded measuring distance Sd 0 ... 2 mm resolution < 0,001mm (stat.) < 0,005 mm (dynam.) < 0,02 mm repeatability linearity error 100 m temperature drift 5% (Full Scale) electrical data response time (factory characteristic) < 0,5 ms voltage supply range +Vs 15 ... 30 VDC short circuit protection yes reverse polarity protection yes voltage output current consumption max. 25 mA output signal 0 ... 10 VDC load resistance > 1000 Ohm current output current consumption max. 35 mA output signal 0 ... 10 mA load resistance +Vs min. < 910 Ohm load resistance +Vs max. < 2400 Ohm mechanical data type cylindrical threaded housing material stainless steel dimension 8 mm ambient conditions operating temperature 10 ... +60 C protection class IP 67 order reference output circuit housing length connection types IWRM 08I9501 current output 40 mm cable IWRM 08I9501/S35 current output 46 mm connector M8 IWRM 08U9501 voltage output 40 mm cable IWRM 08U9501/S35 voltage output 46 mm connector M8 www.baumerelectric.com 21/3/2008