1
Power Entry Modules with Line Filter 5145
https://www.schurter.com /PG06
EMC Products
IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45
Protection class I with shield Protection class II without shield
Approvals and Compliances
C14
70° C
C18
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Compact power entry module with circuit breaker
- High configurability
- Easy assembly with prewired modules
- Protection class I or II
Characteristics
- All single elements are already wired
- Unwired versions available on request
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
References
Alternative: version without line filter 6145
We recommend for new applications the new type DF12
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Tempe-
rature
-10 °C to 55 °C
Climatic Category 10/055/21 acc. to IEC 60068-1
IP-Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness S Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C14 or C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Line Filter Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
MTBF > 100'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5145
Approval Logo Certificates Certification Body Description
VDE Approvals VDE Certificate Number: 40035745
UL Approvals UL UL File Number: E72928
2
Power Entry Modules with Line Filter
5145 https://www.schurter.com /PG06
EMC Products
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Designed according to UL 1283 Electromagnetic interference filters
Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG EU Directive RoHS 2011/65/EU
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
3
Power Entry Modules with Line Filter 5145
https://www.schurter.com /PG06
EMC Products
Dimension [mm]
3.25
+0.1
0
±0.1
43
M3/ø 3.6
2
1
ø 6
Detail A
50.7
67.5* 13.5
6.3x0.8mm
6.3x0.8mm
36
80
91.5
72
80
R 3
29
0
-0.5
0
+0.2
A
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [M]
1Standard Version 2 x 11 47 2.2 -
2Standard Version 2 x 4 47 2.2 -
3Standard Version 2 x 2.5 47 2.2 -
4Standard Version 2 x 1.6 47 2.2 -
6Standard Version 2 x 0.7 47 2.2 -
8Standard Version 2 x 0.6 47 2.2 -
10 Standard Version 2 x 0.4 47 2.2 -
15 Standard Version 2 x 0.1 47 2.2 -
1Medical Version (M5) 2 x 11 47 - 1
2Medical Version (M5) 2 x 4 47 - 1
6Medical Version (M5) 2 x 0.7 47 - 1
8Medical Version (M5) 2 x 0.6 47 - 1
10 Medical Version (M5) 2 x 0.4 47 - 1
15 Medical Version (M5) 2 x 0.1 47 - 1
4
Power Entry Modules with Line Filter
5145 https://www.schurter.com /PG06
EMC Products
Diagrams
Standard version
Cx
L1
L2
Cy
Cy
2)
L’
PE’
N’
P1
P2
L
PE
N
1)
TA 45
1) Line
2) Load
Medical version (M5)
Cx
L1
L2
R
2)
L’
PE’
N’
P1
P2
L
PE
N
1)
TA 45
1) Line
2) Load
Medical filter (M5) protection class II
Cx
L1
L2
R
2)
L’
N’
P1
P2
L
N
1)
TA 45
1) Line
2) Load
Attenuation Loss - - - - 50 differential mode _____ 50 common mode
Standard version
1 A 2 A 3 A 4 A
6 A 8 A 10 A 15A
5
Power Entry Modules with Line Filter 5145
https://www.schurter.com /PG06
EMC Products
Medical version (M5)
1 A 2 A 3 A 4 A
6 A 8 A 10 A 15A
6
Power Entry Modules with Line Filter
5145 https://www.schurter.com /PG06
EMC Products
ABT W F 150 C0
Colours
Switch front Rocker
W black white
B black black
6 black orange transp.
F embossed / Relief
H printed / bedruckt white / weiss
K printed / bedruckt black / schwarz
L printed / bedruckt white / weiss
Surface Illustration Colour of print
Rocker legend
l
O
ON
OFF
ON
OFF
l
O
M printed black
P printed white
R printed black
Surface Illustration Colour of print
Rated current circuit breaker of equipment
Without release: code C0
Undervoltage release Remote trip release
UEZACode
Rated
voltage Un
2
3
4
240 V AC
230 V AC
120 V AC
l
O
OI
OI
Position of the rocker legend
e.g F
In Code
0,1 J01
0,2 J02
0,3 J03
0,4 J04
0,5 J05
0,6 J06
0,7 J07
0,8 J08
0,9 J09
1,0 J10
1,1 J11
1,2 J12
In Code
1,3 J13
1,4 J14
1,5 J15
1,6 J16
1,7 J17
1,8 J18
1,9 J19
2,0 J20
2,1 J21
2,2 J22
2,3 J23
2,5 J25
In Code
2,8 J28
3,0 030
3,5 035
4,0 040
4,5 045
5,0 050
6,0 060
6,5 065
7,0 070
7,5 075
8,0 080
9,0 090
In Code
10,0 100
11,0 110
12,0 120
13,0 130
14,0 140
15,0 150
20,0 200
Table 1 Selection for type TA45
Order example
Circuit Breaker of Equipment
2-pole, rocker actuated
Quick connect terminal
Other types on request
Without illumination
With illumination 220…240 V
110…120 V
Diagram
Thermal overload protection 1-pole 2-pole
ABT ABD
A12 A32
A14 A34
P2 P1
63
43
P2 P1
}
P2 P1
U<
P2 P1
b
U<
P2 P1
ba
U<
P2 P1
c
7
Power Entry Modules with Line Filter 5145
https://www.schurter.com /PG06
EMC Products
Technical data (continued)
Circuit breaker
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
deter mine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10 0,89
5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
Configuration code (example)
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+ 40 °C ambient temperature 6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
Type
Tripping characteristics
In < 3 A
Tripping characteristics
In >_ 3… <_ 15 A
10’000
60
2000
1000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In ]
10854321,32
Tripping time
Type TA45
Rated current In < 3 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
10’000
60
2’000
1’000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
[ x In ]
10854321,32
Type TA45
Rated current I > 3...
< 15 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
Multiple of rated current
Tripping time
n
Optional Variants
00 standard
21 V-Lock notch
Terminal PE
0 without (PCII)
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Metal Shield Filter
0 with metal shield (PCI)
1 without metal shield (PCI and PCII)
Type of mains fi lter / capacitor / bleed resistor
1 standard X2,Y2 without 1)
3 medical M5 X2 with
Rated current 2)
1 1A
2 2A
3 3A
4 4A
5 6A
6 8A
7 10A
8 15A
1) Not in conjunction with PC II
2) The rated current of the line-fi lter must be equal
or more than the rated current of TA45.
see table 1
5145 - ABTWF150C0 - 000 - 111 - 10 - 00
Order code TA45
(2-pole rocker-switch
without accessories)
8
Power Entry Modules with Line Filter
5145 https://www.schurter.com /PG06
EMC Products
Packaging unit 20 Pcs
Accessories
Description
Assorted Covers
Rear Cover
0859.0074
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091
Appliance Outlet further types to 5145
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012
Connector further types to 5145 ...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Power cord with IEC connector C17, V-Lock, straight VAC17KS
Power Cord further types to 5145
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
02.12.2017
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
5-ABTWF150C0-811 5-ABTWF150C0-831 5-ABTWF050C0-531 5-ABTWF050C0-511 5-ABDWF150C0-811 5-
ABDWF150C0-831 5-ABDWF050C0-511 5-ABDWF050C0-531 5-ABDWF100C0-711 5145.ABDWF100C0.811
5145.0646.631