A
C
C
ON
T
R
O
L
(120Vac)
P
F
240A25
MODEL NUMBERS (24Vac)
P
F
E
240A25
D
C
C
ON
T
R
O
L
(5Vdc)
P
F
240D25
P
F
380D25
P
F
480D25
(24Vdc)
P
F
E
240D25
P
F
E
380D25
P
F
E
480D25
OU
T
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
Operating Voltage (47-63 Hz) [Vrms] 12-280 48-530 48-660
Load Current Range [Arms] Forced Air.06-25
Convection Air .06-10
Transient Overvoltage [Vpk] 600 1200 1200
Max. Surge Current, (16.6ms) [Apk] 250 250 250
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6
Maximum I2t for Fusing, (8.3 msec.) [A2sec] 260 260 260
Max. Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] 500 500 500
Max. Turn-On Time 1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec (AC Control)
Power Factor (Min.) with Max. Load 0.5 0.5 0.5
IN
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
D
C
C
ON
T
R
O
L
A
C
C
ON
T
R
O
L
Nominal Voltage 5Vdc 5Vdc 24Vdc 120Vac 24Vac
P
F
E
240D25
MODEL NUMBERS
P
F
380D25
P
F
E
380D25
P
F
240D25
P
F
480D25
P
F
E
480D25
P
F
240A25
P
F
E
240A25
Control Voltage Range 3-15 Vdc 4-15 Vdc 15-32 Vdc 90-140 Vrms 18-36 Vrms
Max. Turn-On Voltage 3.0 Vdc 4.0 Vdc 15.0 Vdc 90.0 Vrms 18.0 Vrms
Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 10.0 Vrms 2.0 Vrms
Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1k Ohm 4.2k Ohm
Typical Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mArms 5 mArms
G
E
N
E
R
A
L
NO
T
ES
All parameters at 25˚C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heatsink temperature 85ûC Maximum.
Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).
•U
ltra
H
igh
S
teady
S
tate
C
urrent
R
ating
L
ow
L
eakage
(O
ff
-
S
tate
)
S
CR
O
utput
A
C
or
D
C
C
ontrol
C
rydom
'
s
P
atented
D
e
s
ign
FastFax Document No. 115
SERIES PF
Rev. 111403
PAGE 1 OF 2
T
M
Crydom's PowerFin
TM
series delivers the
highest ratings of any single in-line pack-
age (SIP). The integral heat sink design
can operate at 25 amps RMS in forced air
at 85˚ûC case temp. With natural convec-
tion in free air, it rates 10 amps RMS at
25û˚C ambient.
Built-in advantages include Surface Mount
Technology and SCR output.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
S
e
r
i
e
s
P
F
,
P
o
w
e
r
F
i
n
U
p
t
o
25
A
m
p
120
/
240
/
380
/
480
V
ac
-
A
C
O
U
T
P
U
T
0 10203040506070 80
AMBIENT TEMPERATURE (˚Cû)
0
2
4
6
8
10
LOAD CURRENT (AMPS)
0
5
10
15
20
25
LOAD CURRENT (AMPS)
0 20406080100120140
HEATSINK TEMPERATURE (˚Cû)
G
E
N
E
R
A
L
SPE
C
I
F
I
C
A
T
ION
S
Dielectric Strength 50/60Hz Input/Output 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output 8 pF
Ambient Operating Temperature Range -30 to 80˚C
Ambient Storage Temperature Range -30 to 125˚C
M
E
C
HANI
C
A
L
SPE
C
I
F
I
C
A
T
ION
S
Weight: (typical) .85 oz. (25g)
Encapsulation: Thermally Conductive Epoxy
All dimensions are in inches (millimeters)
A
PP
R
OVA
L
S
UL E116950
VDE 70938 (DC Control Only)
1.35
MAX.
(34.3)
.700
(17.8) .900
(22.8)
1.70
(43.1)
1.100
(27.9)
.200
(5.1)
.050
(1.3)
.040
(1.0)
DIA.
4 PLACES
.300
(7.6) TYP. .72
(18.3) TYP.
1.6 TYP.
(38.1)
43 2 1
FastFax Document No. 115
SERIES PF
Rev. 111403
PAGE 2 OF 2
F
ig
.1
C
onve
c
tion
C
ooling
F
ig
.2
F
or
c
ed
A
ir
C
ooling
C
U
RR
E
N
T
D
E
R
A
T
IN
G
C
U
R
V
ES
AVAI
L
A
B
L
E
O
P
T
ION
S
R
Random Turn-On (AC & DC Control, 240V Only)
Phase Controllable (DC Control, 240V Only)
Example:
P
F
240A25
R
,
P
F
E
240D25
R
©2003 CRYDOM CORP, Specifications subject to change without notice.
DC CONTROL
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: -DC CONTROL
AC CONTROL
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: AC CONTROL
PIN 4: AC CONTROL
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
T
M
S
e
r
i
e
s
P
F
,
P
o
w
e
r
F
i
n
U
p
t
o
25
A
m
p
120
/
240
/
380
/
480
V
ac
-
A
C
O
U
T
P
U
T