1
GLT540L16
ADVANCED
4M (2-Bank x 131072-Word x 16-Bit) Synchronous DRAM
F
EATURES
Single 3.3 V
±
0.3 V power supply
Clock frequency 100 MHz / 125 MHz / 143 MHz/
166 MHz
Fully synchronous operation referenced to clock
rising edge
Dual bank operation controlled by BA (Bank
Address)
CAS latency- 1 / 2 / 3 (programmable)
Burst length- 1 / 2 / 4 / 8 & Full Page (programmable)
Burst type- sequential / interleave (programmable)
Byte control by DQMU and DQML
Column access - random
Auto precharge / All bank precharge controlled by
A[8]
Auto refresh and Self refresh
1024 refresh cycles / 16 ms
LVTTL Interface
400-mil, 50-Pin Thin Small Outline Package (TSOP II)
with 0.8 mm lead pitch
Single write option
G
ENERAL
D
ESCRIPTION
The GLT540L16 is a 2-bank x 131072-word x 16-bit Syn-
chronous DRAM, with LVTTL interface. All inputs and
outputs are referenced to the rising edge of CLK. The
GLT540L16 achieves very high speed data rate up to
166 MHz.
March 2000 (Rev. 0)
2G-LINK Technology
March 2000 (Rev. 0)
F
UNCTIONAL
B
LOCK
D
IAGRAM
A[8:0]
DQ[15:0]
Figure 1. 4M (2-Bank x 131072-Word x 16-Bit) Synchronous DRAM
Control Circuitry
Address Buffer
BA
CLK
CKE
CS
RAS
Clock Buffer
Control
Signal Buffer
CAS
WE
DQML
DQMU
Mode
Register
Memory Array
Bank #0
Memory Array
Bank #1
I/O Buffer
Signal Description
Signal Type Description
CLK Input Master Clock: All other inputs are referenced to the rising edge of CLK.
CKE Input Clock Enable: CKE controls internal clock. When CKE is low, internal clock for the following cycle is ceased. CKE
is also used to select auto / self refresh. After self refresh mode is started, CKE becomes asynchronous input.
Self refresh is maintained as long as CKE is low.
CS Input Chip Select: When CS is high, any command means No Operation.
RAS, CAS, WE Input Combination of RAS, CAS, WE defines basic commands.
A[8:0] Input A[8:0] specify the Row / Column Address in conjunction with BA. The Row Address is specified by A[8:0]. The
Column Address is specified by A[7:0]. A[8] is also used to indicate precharge option. When A[8] is high at a read
/ write command, an auto precharge is performed. When A[8] is high at a precharge command, both banks are
precharged.
BA Input Bank Address: BA is not simply A[9]. BA specifies the bank to which a command is applied. BA must be set with
ACT, PRE, READ, WRITE commands.
DQ[15:0] Input / Output Data In and Data out are referenced to the rising edge of CLK.
DQML Input Lower Din[7:0] Mask / Lower Output[7:0] Disable: When DQML is high in burst write, lower Din[7:0] for the current
cycle is masked. When DQML is high in burst read, lower Dout[7:0] is disabled at the next but one cycle.
DQMU Input Upper Din[15:8] Mask / Upper Output[15:8] Disable: When DQMU is high in burst write, upper Din(8-15) for the
current cycle is masked. When DQMU is high in burst read, upper Dout[15:8] is disabled at the next but one
cycle.
V
DD
, V
SS
Power Supply Power Supply for the memory array and peripheral circuitry.
V
DDQ
, V
SSQ
Power Supply V
DDQ
and V
SSQ
are supplied to the Output Buffers only.
3
G-LINK Technology
March 2000 (Rev. 0)
F
UNCTIONAL
D
ESCRIPTION
The GLT540L16 provides basic functions, bank (row) acti-
vate, burst read / write, bank (row) precharge, and auto /
self refresh. Each command is defined by control signals
of RAS, CAS and WE at CLK rising edge. In addition to 3
signals, CS, CKE and A[8] are used as chip select, refresh
option, and precharge option, respectively.
To know the detailed definition of commands, please see
the command truth table.
Activate (ACT) [RAS = L, CAS = WE = H]
ACT command activates a row in an idle bank indicated
by BA.
Read (READ) [RAS = H, CAS = L, WE = H]
READ command starts burst read from the active bank
indicated by BA. First output data appears after CAS
latency. When A[8] = H at this command, the bank is
deactivated after the burst read (auto-precharge, READA).
Write (WRITE) [RAS = H, CAS =WE = L]
WRITE command starts burst write to the active bank
indicated by BA. Total data length to be written is set by
burst length. When A[8] = H at this command, the bank is
deactivated after the burst write (auto-precharge,
WRITEA).
Precharge (PRE)
[RAS = L, CAS = H, WE = L]
PRE command deactivates the active bank indicated by
BA. This command also terminates burst read / write
operation. When A[8] = H at this command, both banks
are deactivated (precharge all, PREA).
Auto-Refresh (REFA)
[RAS = CAS = L, WE = CKE = H]
REFA command starts auto-refresh cycle. Refresh
address including bank address are generated internally.
After this command, the banks are precharged automati-
cally. Any other command should not be asserted until
t
RC
is met.
1. H = High Level, L = Low Level, V = Valid, X = Don't Care, n = CLK cycle number
CLK
CS
RAS
CAS
WE
CKE
A[8]
Chip Select: L=select, h=deselect
Command
Command
Command
Define Basic Commands
Refresh option @refresh command
Precharge Option @ precharge or read/write
command
Command T ruth Table
[1]
Command Mnemonic CKE n-1 CKE n CS RAS CAS WE BA A 8 A[7:0]
Deselect DESEL H X H X X X X X X
No Operation NOP H X L H H H X X X
Row Address Entry & Bank Activate ACT H X L L H H V V V
Single Bank Precharge PRE H X L L H L V L X
Precharge All Banks PREA H X L L H L V H X
Column Address Entry & Write WRITE H X L H L L V L V
Column Address Entry & Write with Auto-Precharge WRITEA H X L H L L V H V
Column Address Entry & Read READ H X L H L H V L V
Column Address Entry & Read with Auto-Precharge READA H X L H L H V H V
Auto-Refresh REFA H H L L L H X X X
Self-Refresh Entry REFS H L L L L H X X X
Self-Refresh Exit REFSX L H H X X X X X X
L H L H H H X X X
Burst Terminate TBST H X L H H L X X X
Mode Register Set MRS H X L L L L L L V
4G-LINK Technology
March 2000 (Rev. 0)
Function T ruth Table
[1] [2]
Current State CS RAS CAS WE Address
[3]
Command Action
[4]
IDLE H X X X X DESEL NOP
L H H H X NOP NOP
L H H L BA TBST ILLEGAL
[5]
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
[5]
L L H H BA, RA ACT Bank Active, Latch RA
L L H L BA, A[8] PRE / PREA NOP
[6]
L L L H X REFA Auto-Refresh
[7]
L L L L Op-Code, Mode-Add MRS Mode Register Set
[7]
ROW ACTIVE H X X X X DESEL NOP
L H H H X NOP NOP
L H H L BA TBST NOP
L H L H BA, CA, A[8] READ / READA Begin Read, Latch CA, Determine Auto-
Precharge
L H L L BA, CA, A[8] WRITE / WRITEA Begin Write, Latch CA, Determine Auto-
Precharge
L L H H BA, RA ACT Bank Active / ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA Precharge / Precharge All
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
READ H X X X X DESEL NOP (Continue Burst to END)
L H H H X NOP NOP (Continue Burst to END)
L H H L BA TBST Terminate Burst
L H L H BA, CA, A[8] READ / READA Terminate Burst, Latch CA, Begin New
Read, Determine Auto-Precharge
[8]
L H L L BA, CA, A[8] WRITE / WRITEA Terminate Burst, Latch CA, Begin Write,
Determine Auto-Precharge
[8]
L L H H BA, RA ACT Bank Active / ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA Terminate Burst, Precharge
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
WRITE H X X X X DESEL NOP (Continue Burst to END)
L H H H X NOP NOP (Continue Burst to END)
L H H L BA TBST Terminate Burst
L H L H BA, CA, A[8] READ / READA Terminate Burst, Latch CA, Begin Read,
Determine Auto-Precharge
[8]
L H L L BA, CA, A[8] WRITE / WRITEA Terminate Burst, Latch CA, Begin Write,
Determine Auto-Precharge
[8]
L L H H BA, RA ACT Bank Active / ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA Terminate Burst, Precharge
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
5
G-LINK Technology
March 2000 (Rev. 0)
READ with AUTO
PRECHARGE
H X X X X DESEL NOP (Continue Burst to END)
L H H H X NOP NOP (Continue Burst to END)
L H H L BA TBST ILLEGAL
L H L H BA, CA, A[8] READ / READA ILLEGAL
L H L L BA, CA, A[8] WRITE / WRITEA ILLEGAL
L L H H BA, RA ACT Bank Active / ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA ILLEGAL
[5]
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
WRITE with AUTO
PRECHARGE
H X X X X DESEL NOP (Continue Burst to END)
L H H H X NOP NOP (Continue Burst to END)
L H H L BA TBST ILLEGAL
L H L H BA, CA, A[8] READ / READA ILLEGAL
L H L L BA, CA, A[8] WRITE / WRITEA ILLEGAL
L L H H BA, RA ACT Bank Active / ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA ILLEGAL
[5]
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
PRE -CHARGING H X X X X DESEL NOP (Idle after t
RP
)
L H H H X NOP NOP (Idle after t
RP
)
L H H L BA TBST ILLEGAL
[5]
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
[5]
L L H H BA, RA ACT ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA NOP
[6]
(Idle after t
RP
)
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
ROW ACTIVATING H X X X X DESEL NOP (Row Active after t
RCD
)
L H H H X NOP NOP (Row Active after t
RCD
)
L H H L BA TBST ILLEGAL
[5]
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
[5]
L L H H BA, RA ACT ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA ILLEGAL
[5]
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
WRITE RECOVERING H X X X X DESEL NOP
L H H H X NOP NOP
L H H L BA TBST ILLEGAL
[5]
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
[5]
L L H H BA, RA ACT ILLEGAL
[5]
L L H L BA, A[8] PRE / PREA ILLEGAL
[5]
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
Function T ruth Table
[1] [2]
(Continued)
Current State CS RAS CAS WE Address
[3]
Command Action
[4]
6G-LINK Technology
March 2000 (Rev. 0)
1. H = High Level, L= Low Level, X = Don't Care.
2. All entries assume that CKE was High during the preceding clock cycle and the current clock cycle.
3. BA = Bank Address, RA = Row Address, CA = Column Address, NOP = No OPeration.
4. ILLEGAL = Device operation and/or data-integrity are not guaranteed.
5. ILLEGAL to bank in specified state; function may be legal in the bank indicated by BA, depending on the state of that bank.
6. NOP to bank precharging or in idle state. May precharge bank indicated by BA.
7. ILLEGAL if any bank is not idle.
8. Must satisfy bus contention, bus turn around, write recovery requirements.
REFRESHING H X X X X DESEL NOP (Idle after t
RC
)
L H H H X NOP NOP (Idle after t
RC
)
L H H L BA TBST ILLEGAL
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
L L H H BA, RA ACT ILLEGAL
L L H L BA, A[8] PRE / PREA ILLEGAL
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
MODE REGISTER
SETTING
H X X X X DESEL NOP (Idle after t
RSC
)
L H H H X NOP NOP (Idle after t
RSC
)
L H H L BA TBST ILLEGAL
L H L X BA, CA, A[8] READ / WRITE ILLEGAL
L L H H BA, RA ACT ILLEGAL
L L H L BA, A[8] PRE / PREA ILLEGAL
L L L H X REFA ILLEGAL
L L L L Op-Code, Mode-Add MRS ILLEGAL
Function T ruth Table
[1] [2]
(Continued)
Current State CS RAS CAS WE Address
[3]
Command Action
[4]
7
G-LINK Technology
March 2000 (Rev. 0)
1. H = High Level, L= Low Level, X = Don't Care.
2. CKE Low to High transition will re-enable CLK and other inputs asynchronously. A minimum setup time must be satisfied before any command other than EXIT.
3. Power-Down and Self-Refresh can be entered only from the All Banks Idle State.
4. Must be legal command.
Function T ruth Table for CKE
[1]
Current State CKE n-1 CKE n CS RAS CAS WE Add Action
SELF-REFRESH
[2]
H X X X X X X INVALID
L H H X X X X Exit Self-Refresh (Idle after t
RC
)
L H L H H H X Exit Self-Refresh (Idle after t
RC
)
L H L H H L X ILLEGAL
L H L H L X X ILLEGAL
L H L L X X X ILLEGAL
L L X X X X X NOP (Maintain Self-Refresh)
POWER DOWN H X X X X X X INVALID
L H X X X X X Exit Power Down to Idle
L L X X X X X NOP (Maintain Self-Refresh)
ALL BANKS IDLE
[3]
H H X X X X X Refer to Function Truth Table
H L L L L H X Enter Self-Refresh
H L H X X X X Enter Power Down
H L L H H H X Enter Power Down
H L L H H L X ILLEGAL
H L L H L X X ILLEGAL
H L L L X X X ILLEGAL
L X X X X X X Refer to Current State = Power Down
ANY STATE other than
listed above
H H X X X X X Refer to Function Truth Table
H L X X X X X Begin CLK Suspend at Next Cycle
[4]
L H X X X X X Exit CLK Suspend at Next Cycle
[4]
L L X X X X X Maintain CLK Suspend
8G-LINK Technology
March 2000 (Rev. 0)
Power On Sequence
Before starting normal operation, the following power on
sequence is necessary to prevent damage or malfunction.
1. Apply power and start clock. Attempt to maintain
CKE high, DQMU / DQML high and NOP condition
at the inputs.
2. Maintain stable power, stable clock, and NOP input
conditions for a minimum of 200
m
s.
3. Issue precharge commands for all banks. (PRE or
PREA)
4. After all banks become idle state (after t
RP
), issue 2
or more auto-refresh commands.
5. Issue a mode register set command to initialize the
mode register.
After this sequence, the SDRAM is idle state and ready for
normal operation.
MODE
REGISTER
SET
PRECHARGEPOWER ON
POWER
APPLIED PRE
SELF
REFRESH
IDLE AUTO
REFRESH
CLK
SUSPEND
ROW ACTIVE
WRITE
SUSPEND WRITE READ READ
SUSPEND
WRITE A
SUSPEND WRITE A READ A READ A
SUSPEND
PRE
PRE
PRE
CKEH
CKELCKEL
CKEH
CKEL
CKEH
CKEL
CKEH
WRITE A READE A
WRITE A READE A
WRITE
READ
WRITE A READE A
WRITE READ
POWER
DOWN
CKEL
CKEH
ACT
CKEL
CKEH
MRS REFA
REFS
REFSX
Automatic Sequence
Command Sequence
Figure 2. Simplified State Diagram
TBST TBST
9
G-LINK Technology
March 2000 (Rev. 0)
Mode Register
Burst Length, Burst Type and CAS Latency can be pro-
grammed by setting the mode register (MRS). The mode
register stores these data until the next MRS command,
which may be issued when both banks are in idle state.
After t
RSC
from a MRS command, the SDRAM is ready for
new command.
CLK
CS
RAS
CAS
WE
BA, A[8:0]
BA A8 A7 A6 A5 A4 A3 A2 A1 A0
WBL 0 Ø LTMODE BT BL
000
CL
001
CAS LATENCY
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
R
1
2
3
R
R
R
R
000
BL
001
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
BT = 0 BT = 1
1
2
4
8
R
R
R
Full Page
1
2
4
8
R
R
R
R
1
SEQUENTIAL
INTERLEAVED
0BURST
TYPE
BURST
LENGTH
LATENCY
MODE
Write Burst Length (WBL)
BA
0
1
Length
= BL specified
Single bit (BL = 1)
CLK
Command READ
Address
DQ
WRITE
Q0 Q1 Q3
Y
Q2 D0 D1 D3D2
CAS Latency Burst Length Burst Length
Y
Burst Type
Initial
Address BL Column Addressing
A2 A1 A0 Sequential Interleaved
00080123456701234567
001 1234567010325476
010 2345670123016745
011 3456701232107654
100 4567012345670123
101 5670123454761032
110 6701234567452301
111 7012345676543210
–0040123 0123
–01 1230 1032
–10 2301 2301
–11 3012 3210
–0201 01
––1 10 10
10 G-LINK Technology
March 2000 (Rev. 0)
O
PERATIONAL
D
ESCRIPTION
Bank Activate
The SDRAM has two independent banks. Each bank is
activated by the ACT command with the bank address
(BA). A row is indicated by the row address A[8:0] The
minimum activation interval between one bank and the
other bank is t
RRD
.
Precharge
The PRE command deactivates the bank indicated by BA.
When both banks are active, the precharge all command
(PREA, PRE + A[8] = H) is available to deactivate them at
the same time. After t
RP
from the precharge, an ACT com-
mand can be issued.
CLK
Figure 3. Bank Activation and Precharge All (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT ACT READ PRE ACT
Xa
Xa
0
Xb Ya
Xb 0
01 1
Xb
Xb
1
Qa2Qa1Qa0 Qa3
Precharge All
tRRD tRAS tRP
11
G-LINK Technology
March 2000 (Rev. 0)
Read
After t
RCD
from the bank activation, a READ command
can be issued. 1st output data is available after the CAS
Latency from the READ, followed by (BL-1) consecutive
data when the Burst Length is BL. The start address is
specified by A[7:0], and the address sequence of burst
data is defined by the Burst Type. A READ command may
be applied to any active bank, so the row precharge time
(t
RP
) can be hidden behind continuous output data (in
case of BL = 4) by interleaving the dual banks. When A[8]
is high at a READ command, the auto-precharge (READA)
is performed. Any command (READ, WRITE, PRE, ACT) to
the same bank is inhibited till the internal precharge is
complete. The internal precharge start timing depends on
CAS Latency. The next ACT command can be issued after
t
RP
from the internal precharge timing.
CLK
Figure 4. Dual Bank Interleaving READ (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT READ ACT PRE
Qa2Qa1Qa0 Qa3
READ
Xa Ya Xb Yb
Xa 0 Xb 00
0 0 1 01
Qb0 Qb1 Qb2
tRCD
CAS Latency
Burst Length
CLK
Figure 5. READ with Auto-Precharge (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT READ A ACT
Qa2Qa1Qa0 Qa3
tRCD
Xa Y Xa
Xa 1 Xa
0 0 0
tRP
Internal Precharge begins
CLK
Figure 6. READ Auto-Precharge Timing (BL=4)
Command
CL=3 DQ
CL=2 DQ
ACT READ A
Internal Precharge Start Timing
Qa2Qa1Qa0 Qa3
Qa2Qa1Qa0 Qa3
12 G-LINK Technology
March 2000 (Rev. 0)
Write
After tRCD from the bank activation, a WRITE command
can be issued. 1st input data is set at the same cycle as
the WRITE. Following (BL-1) data are written into the
RAM, when the Burst Length is BL. The start address is
specified by A[7:0], and the address sequence of burst
data is defined by the Burst Type. A WRITE command
may be applied to any active bank, so the row precharge
time (tRP) can be hidden behind continuous input data (in
case of BL = 4) by interleaving the dual banks. From the
last input data to the PRE command, the write recovery
time (tRDL) is required. When A[8] is high at a WRITE com-
mand, the auto-precharge (WRITEA) is performed. Any
command (READ, WRITE, PRE, ACT) to the same bank is
inhibited till the internal precharge is complete. The inter-
nal precharge begins at tWR after the last input data cycle.
The next ACT command can be issued after tRP from the
internal precharge timing.
CLK
Figure 7. Dual Bank Interleaving WRITE (BL=4)
Command
A[7:0]
A[8]
BA
DQ
tRCD tRCD
Burst Length
tRDL (1 CLK)
Da2Da1Da0 Da3
ACT WRITE ACT PREWRITE
Xa Y Xb Y
Xa 0 Xb 00
0 0 1 01
Db1Db0 Db3Db2
CLK
Figure 8. WRITE with Auto-Precharge (BL=4)
Command
A[7:0]
A[8]
BA
Internal Precharge Begins
DQ
tRCD tRP
tRDL
Da2Da1Da0 Da3
ACT WRITE ACT
Xa Y Xa
Xa 1 Xa
0 0 0
13G-LINK Technology
March 2000 (Rev. 0)
Burst Interruption
[Read Interrupted by Read]
The burst read operation can be interrupted by a new
read of the same or the other bank. GLT540L16 allows
random column access. READ to READ interval is 1 CLK
minimum.
[Read Interrupted by Write]
Burst read operation can be interrupted by write of the
same or the other bank. Random column access is
allowed. In this case, the DQ should be controlled ade-
quately by using the DQMU / DQML to prevent the bus
contention. The output is disabled automatically 2 cycles
after WRITE assertion.
CLK
Figure 9. READ Interrupted by READ (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
Internal Precharge Start Timing
DQ
0
Qj1Qj0Qi0 Qk0
READ READ READ
Qk2Qk1 Ql1Ql0
READ
Yi Yk YlYj
0 0 00
0 10
Ql2 Ql3
CLK
Command
A[7:0]
A[8]
BA
DQMU, DQML
Figure 10. READ Interrupted by WRITE (BL=4, CL=3)
Q
D Dj0
Qi0
Dj1
READ
Dj3Dj2
WRITE
Yi Yj
0 0
0 0
DQM U/ DQML control Write control
14 G-LINK Technology
March 2000 (Rev. 0)
[Read Interrupted by Precharge]
Burst read operation can be interrupted by precharge of
the same bank. READ to PRE interval is minimum 1 CLK.
A PRE command disables the data output, depending on
the CAS Latency. The figure below shows examples,
when the data-out is terminated.
Figure 11. READ Interrupted by Precharge (BL=4)
CLK
Command
DQ
Command
DQ
Command
DQ
Command
DQ
Command
DQ
Command
DQ
CL=2
CL=3
Q 0
READ PRE
READ PRE
READ PRE
READ PRE
READ PRE
READ PRE
Q 0 Q 1 Q 2 Q 3
Q 0 Q 1 Q 2
Q 0
Q 0 Q 1 Q 2 Q 3
Q 0 Q 1 Q 2
15G-LINK Technology
March 2000 (Rev. 0)
[Read Interrupted by Burst Terminate]
Similarly to the precharge, burst terminate command can
interrupt burst read operation and disable the data out-
put. READ to TBST interval is minimum 1 CLK. The figure
below shows examples, when the data-out is terminated.
CLK
Command
DQ
Command
DQ
Command
Figure 12. READ Interrupted by Burst Terminate (BL=4)
DQ
Command
DQ
Command
DQ
Command
DQ
CL=2
CL=3
Q 0
READ TBST
Q 1 Q 2 Q 3
READ TBST
Q 0 Q 1 Q 2
READ
Q 0
TBST
Q 0 Q 1 Q 2 Q 3
Q 0 Q 1 Q 2
Q 0
READ TBST
READ TBST
READ TBST
16 G-LINK Technology
March 2000 (Rev. 0)
[Write Interrupted by Write]
Burst write operation can be interrupted by new write of
the same or the other bank. Random column access is
allowed. WRITE to WRITE interval is minimum 1 CLK.
[Write Interrupted by Read]
Burst write operation can be interrupted by read of the
same or the other bank. Random column access is
allowed. WRITE to READ interval is minimum 1 CLK. The
input data on DQ at the interrupting READ cycle is
“don't care”. Using the DQMU / DQML to prevent the bus
contention is optional.
CLK
Command
A[7:0]
A[8]
BA
DQ
Figure 13. WRITE Interrupted by WRITE (BL=4)
Dj1Dj0Di0 Dk0
WRITE
Dk2Dk1 Dl1Dl0
Yi Yk YlYj
0 0 00
0 1 00
Dl2 Dl3
WRITE WRITE WRITE
CLK
Command
DQ
Figure 14. WRITE interrupted by READ (BL=4, CL=3)
A[7:0]
A[8]
BA
DQMU, DQML
WRITE READ
0 0
Di0 Qj1Qj0 Dk0 Dk1
WRITE READ
Yi Yj Yk Yl
0 0 0 0
0 1
Ql0
17G-LINK Technology
March 2000 (Rev. 0)
[Write Interrupted by Precharge]
Burst write operation can be interrupted by precharge of
the same bank. Random column access is allowed.
Because the write recovery time (tRDL) is required
between the last input data and the next PRE, 3rd data
should be masked with DQMU / DQML shown as below.
[Write Interrupted by Burst Terminate]
Burst terminate command can terminate burst write
operation. In this case, the write recovery time is not
required and the bank remains active. The figure below
shows the case 3 words of data are written. Random col-
umn access is allowed. WRITE to TBST interval is
minimum 1 CLK.
CLK
Command
DQ
Figure 15. WRITE Interrupted by Precharge (BL=4)
A[7:0]
A[8]
BA
DQMU, DQML
This data should be masked to satisfy tRDL requirement.
0
0
Di0
Ya Xb
WRITE PRE ACT
0 Xb
0 0
Di1
CLK
Command
DQ
Figure 16. WRITE Interrupted by Burst Terminate (BL=4)
A[7:0]
A[8]
BA
DQMU, DQML
Da0
Ya
WRITE TBST
Da1
0
0
Da2
18 G-LINK Technology
March 2000 (Rev. 0)
Auto Refresh
Single cycle of auto-refresh is initiated with a REFA
(CS = RAS = CAS = L, WE = CKE = H) command. The
refresh address is generated internally. 1024 REFA cycles
within 16 ms refresh 4 Mbit memory cells. The auto-
refresh is performed on each bank alternately (ping-pong
refresh). Before performing an auto-refresh, both banks
must be in the idle state. Additional commands must not
be supplied to the device before tRC from the REFA
command.
Self Refresh
Self-refresh mode is entered by issuing a REFS command
(CS = RAS = CAS = L, WE = H, CKE = L). Once the self-
refresh is initiated, it is maintained as long as CKE is kept
low. During the self-refresh mode, CKE is asynchronous
and the only enabled input (but asynchronous), all other
inputs including CLK are disabled and ignored, and
power consumption due to synchronous inputs is saved.
To exit the self-refresh, supplying stable CLK inputs,
asserting DESEL or NOP command and then asserting
CKE (REFSX). After tRC from REFSX both banks are in the
idle state and a new command can be issued after tRC, but
DESEL or NOP commands must be asserted till then.
CLK
CS
A[8:0]
Figure 17. Auto Refresh
RAS
CAS
WE
CKE
BA
NOP or Deselect
Minimum tRC
Auto Refresh on Bank 0 Auto Refresh on Bank 1
minimum tRC for recovery
CLK
CS
A[8:0]
Figure 18. Self-Refresh
RAS
CAS
WE
CKE
BA
Stable CLK
Self Refresh Entry Self Refresh Exit
NOP
new command
X
0
19G-LINK Technology
March 2000 (Rev. 0)
CLK Suspend
CKE controls the internal CLK at the following cycle.
Figure 19 and Figure 20 show how CKE works. By negat-
ing CKE, the next internal CLK is suspended. The purpose
of CLK suspend is power down, output suspend or input
suspend. CKE is a synchronous input except during the
self-refresh mode. CLK suspend can be performed either
when the banks are active or idle, but a command at the
following cycle is ignored.
ext. CLK
CKE
int. CLK
CLK
CKE
Figure 19. Power Down by CKE
Command
CKE
Command
Standby Power Down
Active Power Down
NOPPRE NOP NOP NOP NOP NOP NOP
NOPACT NOP NOP NOP NOP NOP NOP
CLK
CKE
Figure 20. DQ Suspend by CKE
Command
DQ
WRITE READ
D0 D1 D2 D3 Q0 Q1 Q2 Q3
20 G-LINK Technology
March 2000 (Rev. 0)
DQMU / DQML Control
DQMU / DQML is a dual function signal defined as the
data mask for writes and the output disable for reads.
During writes, DQMU / DQML masks upper / lower input
data word by word. DQMU / DQML to write mask latency
is 0. During reads, DQMU / DQML forces upper / lower
output to Hi-Z word by word. DQMU / DQML to output Hi-
Z latency is 2.
CLK
Command
Figure 21. DQMU / DQML Function
DQ[7:0]
DQMU
DQ[15:8]
DQML
Masked by DQML = High
Masked by DQMU = High Disabled by DQMU =High
Disabled by DQML = High
D2D0 D3 Q0 Q1 Q3
WRITE READ
D1D0 D3 Q0 Q3Q2
21G-LINK Technology
March 2000 (Rev. 0)
ELECTRICAL SPECIFICATIONS
1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and functional operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
1. VIH (max) = 5.6 V for pulse width less than 3 ns.
2. VIL (min) = -2.0 V for pulse width less than 3 ns.
Absolute Maximum Ratings [1]
Symbol Parameter Conditions Ratings Unit
VDD Supply Voltage with respect to VSS -1.0 to 4.6 V
VDDQ Supply Voltage for Output with respect to VSSQ -1.0 to 4.6 V
VIInput Voltage with respect to VSS -1.0 to 4.6 V
VOOutput Voltage with respect to VSSQ -1.0 to 4.6 V
IOOutput Current 50 mA
PDPower Dissipation TA = 25 °C 1000 mW
TOPR Operating Temperature 0 to 70 °C
TSTG Storage Temperature -65 to 150 °C
Recommended Operating Conditions (TA = 0 to +70°C, unless otherwise noted)
Symbol Parameter Min Typ Max Unit
VDD Supply Voltage 3.0 3.3 3.6 V
VDDQ Supply Voltage for Output 3.0 3.3 3.6 V
VIH [1] High-Level Input Voltage all inputs 2.0 VDDQ + 0.3 V
VIL [2] Low-Level Input Voltage all inputs -0.3 0.8 V
DC Characteristics (TA = 0 to +70°C, VDD = VDDQ = 3.3 ±0.3V , VSS = VSSQ = 0 V, unless otherwise noted)
Symbol Parameter Test Conditions Min Max Unit
VOH High-Level Output Voltage IOH = -2 mA 2.4 V
VOL Low-Level Output Voltage IOL = 2 mA 0.4 V
IOZ Off-state Output Current Q floating VO = 0 to VDDQ -10 10 mA
IIInput Current VIH = 0 to VDDQ + 0.3 V -10 10 mA
Capacitance (TA = 0 to +70°C, VDD = VDDQ = 3.3 ±0.3 V , VSS = VSSQ = 0 V, unless otherwise noted)
Symbol Parameter Test Condition Min Max Unit
CI(A) Input Capacitance, address pin VI = VSS
f = 1 MHz
VI = 25 mVrms
2.5 5 pF
CI(C) Input Capacitance, control pin 2.5 5 pF
CI(K) Input Capacitance, CLK pin 2.5 5 pF
CI/O Input Capacitance, I/O pin 4 7 pF
22 G-LINK Technology
March 2000 (Rev. 0)
1. Input Pulse Levels: 0.8 V to 2.0 V. Input Timing Measurement Level: 1.4 V.
Average Supply Current from VDD
(TA = 0 to +70°C, VDD = VDDQ = 3.3 ±0.3 V, VSS = VSSQ = 0 V, unless otherwise noted)
Symbol Parameter Test Conditions
Rating (Max)
Unit-6 -7 -8 -10
ICC1S Operating Current, Single Bank tRC = min, tCLK = min, BL = 1, CL = 3 120 110 100 90 mA
ICC1D Operating Current, Dual Bank tRC = min, tCLK = min, BL = 1, CL = 3 170 150 140 120 mA
ICC2H Standby Current, CKE = H both banks idle, tCLK = min, CKE = H 20 20 20 20 mA
ICC2L Standby Current, CKE = L both banks idle, tCLK = min, CKE = L 2222mA
ICC3H Active Standby Current, CKE = H both banks active, tCLK = min, CKE = H 35 35 35 35 mA
ICC3L Active Standby Current, CKE = L both banks active, tCLK = min, CKE = L 2222mA
ICC4 Burst Current tCLK = min, BL = 4, CL = 3, both banks active 150 140 130 120 mA
ICC5 Auto-Refresh Current tRC = min, tCLK = min 110 100 90 80 mA
ICC6 Self-Refresh Current CKE < 0.2 V 1111mA
Low Power 300 300 300 300 mA
AC Characteristics (TA = 0 to +70°C, VDD = VDDQ = 3.3 ±0.3 V, VSS = VSSQ = 0 V, unless otherwise noted) [1]
Symbol Parameter
-6 -7 -8 -10
UnitMin Max Min Max Min Max Min Max
tCLK CLK Cycle Time CL=2 9 10 13 ns
CL=3 6 7 8 10 ns
tCH CLK High Pulse Width 2.0 2.5 3 3.5 ns
tCL CLK Low Pulse Width 2.0 2.5 3 3.5 ns
tTTransition Time of CLK 1 10 1 10 1 10 1 10 ns
tIS Input Setup Time (all inputs) 2 2.5 2.5 2.5 ns
tIH Input Hold Time (all inputs) 1 1 1 1 ns
tRC Row Cycle Time 60 63 72 90 ns
tRCD Row to Column Delay 18 21 24 30 ns
tRAS Row Active Time 42 100k 42 100k 48 100k 60 100k ns
tRP Row Precharge Time 18 21 24 30 ns
tCCD Column Address to Column Address Delay 1 1 1 1 CLK
tRRD Act to Act Delay Time 2 2 2 2 CLK
tRSC Mode Register Set Cycle Time 2 2 2 2 CLK
tRDL Last Data-In to Row Precharge Delay 1 1 1 1 CLK
tREF Refresh Interval Time 16.4 16.4 16.4 16.4 ms
1.4VCLK
Signal 1.4V
Any AC timing is ref-
erenced to the input
signal crossing
23G-LINK Technology
March 2000 (Rev. 0)
Switching Characteristics (TA = 0 to +70°C, VDD = VDDQ = 3.3 ±0.3 V , VSS = VSSQ = 0 V unless otherwise noted)
Symbol Parameter
-6 -7 -8 -10
UnitMin Max Min Max Min Max Min Max
tAC Access Time from CLK CL = 3 5.5 6 6 7 ns
tOH Output Hold Time from CLK 2 2.5 3 3 ns
tOLZ Delay Time, Output Low Impedance from CLK 1 1 1 1 ns
tOHZ Delay Time, Output High Impedance from CLK 5.5 6 6 7 ns
1.4VCLK
DQ 1.4V
Output Timing Measurement Reference Point
1.4VCLK
DQ 1.4V
tAC tOH tOHZ
-
+
VREF = 1.4V
VTT = 1.4V
VOUT
50 W
50 pF (1)
Figure 22. Output Load Condition
1. For GLT540L16-6, -7, the Output Load is 30 pF.
24 G-LINK Technology
March 2000 (Rev. 0)
Figure 23. WRITE Cycle (single bank) BL=4
tRCD tRDL
tRAS tRP
tRC
Xa
HIGH
Xb
XbXa
D D D D
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
ACT
B0 B0 B0 B0
WRITE PRE ACT
Yi
25G-LINK Technology
March 2000 (Rev. 0)
Figure 24. WRITE Cycle (Dual Bank) BL=4
tRCD
tRDL
tRAS
tRC
Xa
Xa
YbYa Xb
Xb
Da0 Da1 Da2 Da3 Db0 Db1 Db2 Db3
tRP
tRCD
tRRD tRAS
tRDL
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
HIGH
ACT
B0 B0 B1B1 B0 B1
WRITE WRITEACT PRE PRE
26 G-LINK Technology
March 2000 (Rev. 0)
Figure 25. READ Cycle (Single Bank) BL=4, CL=3
tRCD
tRAS
tRC
X
X
XY
tRP
tRCD
X2
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ QQQQ
ACT READ PRE
27G-LINK Technology
March 2000 (Rev. 0)
Figure 26. READ Cycle (Dual Bank) BL=4, CL=3
tRCD
Xa YY Xb
Xa Xb
Xa
Xa
tRCD
tRRD
tRC
tRAS
tRAS tRP
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ Qa Qa Qa Qa Qb Qb Qb Qb
ACT READ READ PRE ACT
28 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 27. WRITE to READ (Single Bank) BL=4, CL=3
X YY
X
tRAS
tRCD
DDDD QQQQ
ACT WRITE READ
29G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 28. WRITE to READ (Dual Bank) BL=4, CL=3
Xa YY Xb Xa
Xa Xb Xa
tRCD
tRRD
tRC
tRAS
tRAS tRP
tWR
tRCD
Da Da Da Da Qb0 Qb1 Qb2 Qb3
ACT WRITE ACT READ PRE PRE ACT
30 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQML
A[7:0]
A[8]
BA
DQ[7:0]
Figure 29. DQM Byte Control for WRITE 3030to READ (Single Bank) BL=4, CL=3
DQMU
DQ[15:8]
X YY
X
Q
tRAS
tRCD
DDD
DDDQQQ
QQ
ACT WRITE READ
31G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 30. READ to WRITE (Single Bank) BL=4, CL=3
Xa YY
Xa
tRAS
tRCD tWR
for output disable
DDDQa0 Qa1 D
READPRE WRITE PRE
32 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 31. READ to WRITE (Dual Bank) BL=4, CL=3
for output disable
Xa YY Xb
Xa Xb
Xa
Xa
tRC
tRCD
tRRD tRAS
tRAS tRP
tRCD
tWR
Db Db DbQa Qa Db
ACT READ PRE ACTACT WRITE PRE
33G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 32. Write with Auto-Precharge BL=4
DQMU, DQML
X XY
X X
tRC33
tRCD tWR + tRP
Internal Precharge starts
this timing depends on BL
D D D D
ACT WRITE A ACT
34 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 33. Read with Auto-Precharge BL=4, CL=3
DQMU, DQML
X XY
X X
Internal Precharge start s @ CL=3, BL=4
this timing depends on CL and BL
tRC
tRCD tRP
Q Q Q Q
ACT READ ACT
35G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 34. Auto-Refresh
DQMU, DQML
If any bank is active, it
must be precharged
tRC
tRP
PRE A REF S REF S
36 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 35. Self-Refresh Entry
DQMU, DQML
If any bank is active, it
must be precharged
tRP
PRE A REF S
37G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 36. Self-Refresh Exit
DQMU, DQML
X
X
NOP or desel
tRC
tSRX
Internal CLK Re-start ACT
38 G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 37. Mode Register Set BL=4, CL=3
DQMU, DQML
X
YMode X
tRP tRPC tRCD
If any bank is
active, it must be
precharged
Q Q Q
PRE A MRS ACT READ
39G-LINK Technology
March 2000 (Rev. 0)
PACKAGING INFORMATION
Figure 38. 50-Pin 400 mil TSOP II Pin Assignment
VDD
DQ0
VSSQ
DQ2
DQ3
VDDQ
DQ4
DQ5
VSSQ
DQ6
DQML
WE
CAS
RAS
CS
BA
A8/AP
VDDQ
DQ11
DQ10
VSSQ
DQ9
DQ8
VDDQ
NC
DQMU
CLK
NC
NC
A7
A6
A5
A4
VSS
1
2
3
4
5
6
7
8
9
10
13
14
15
16
17
18
19
20
44
43
42
41
40
39
38
37
36
35
32
31
30
29
28
27
26
Top View
A0
A1
21
22
DQ7
VDDQ
11
12
34
33
CKE
NC
23
24
25
45
46
47
48
49
50
A2
A3
VDD
DQ12
DQ13
VSSQ
DQ14
DQ15
VSS
DQ1
40 G-LINK Technology
March 2000 (Rev. 0)
0.3 +0.1/-0.05
10.16 ± 0.1
20.95 ± 0.1
21.35 max.
0.8
0.125 + 0.05
- 0.02
0.1
11.76 ± 0.2
0.5 ± 0.1
0.125 ± 0.075
1.0 ± 0.10
1 25
2650
Detail A
Detail A 0°~10°
Figure 39. 50-Pin 400 mil Plastic TSOP II Package Dimensions
41G-LINK Technology
March 2000 (Rev. 0)
ORDERING INFO
GLT5160L16
Part Number Mode Cycle Time Max Frequency Interface Package
GLT540L16-10TC Synchronous 10 100 MHz LVTTL 50-Pin 400 mil Plastic TSOP II
GLT540L16-8TC Synchronous 8 125 MHz LVTTL 50-Pin 400 mil Plastic TSOP II
GLT540L16-7TC Synchronous 7 143 MHz LVTTL 50-Pin 400 mil Plastic TSOP II
GLT 540L16-6TC Synchronous 6 166MHz LVTTL 50-Pin 400 mil Plastic TSOP ll
42 G-LINK Technology
March 2000 (Rev. 0)
43G-LINK Technology
March 2000 (Rev. 0)
© 1999 G-LINK Technology
All rights reserved. No part of this document may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of
G-LINK Technology.
Circuit diagrams utilizing G-LINK products are included as a means of illustrating typical semiconductor applications. Complete information sufficient for design purposes is
not necessarily given.
G-LINK Technology reserves the right to change products or specifications without notice.
The information contained in this document does not convey any license under copyrights, patent rights or trademarks claimed and owned by G-LINK or its subsidiaries.
G-LINK assumes no liability for G-LINK applications assistance, customer’s product design, or infringement of patents arising from use of semiconductor devices in such
systems’ designs. Nor does G-LINK warrant or represent that any patent right, copyright, or other intellectual property right of G-LINK covering or relating to any combination,
machine, or process in which such semiconductor devices might be or are used.
G-LINK Technology’s products are not authorized for use in life support devices or systems. Life support devices or systems are device or systems which are: a) intended for
surgical implant into the human body and b) designed to support or sustain life; and when properly used according to label instructions, can reasonably be expected to cause
significant injury to the user in the event of failure.
The information contained in this document is believed to be entirely accurate. However, G-LINK Technology assumes no responsibility for inaccuracies.
www.glinktech.com
G-LINK Technology
2701 Northwestern Parkway
Santa Clara, CA 95051, USA
TEL: 408-492-9068 • FAX: 408-492-9067
G-LINK Technology Corporation, Taiwan
6F, No. 24-2, Industry E. Rd. IV
Science-Based Industrial Park
Hsin Chu, Taiwan, R.O.C.
TEL: 03-578-2833 • FAX: 03-578-5820
Printed in USA