73S1210F Self-Contained Smart Card Reader with PINpad and Power Management Simplifying System IntegrationTM DATA SHEET May 2009 GENERAL DESCRIPTION The 73S1210F is a versatile and economical CMOS System-on-Chip device intended for smart card reader applications. The circuit is built around an 80515 highperformance core; it features primarily an ISO-7816 / EMV interface and a generic asynchronous serial interface. Delivered with turnkey Teridian embedded firmware, it forms a ready-to-use smart card reader solution that can be seamlessly incorporated into any microprocessor-based system where a serial line is available. The solution is scalable, thanks to a built-in I2C interface that allows to drive external electrical smart card interfaces such as Teridian 73S8010 ICs. This makes the solution immediately able to support multi-card slots or multi-SAM architectures. In addition, the 73S1210 features a 5x6 PINpad interface, 8 user I/Os, multiple interrupt options and an analog voltage input (for DC voltage monitoring such as battery level detection) that make it suitable for low-cost PINpad reader devices. The 80515 CPU core instruction set is compatible with the industry standard 8051, while offering one clock-cycle per instruction processing power (most instructions). With a CPU clock running up to 24MHz, it results in up to 24MIPS available that meets the requirements of various encryption needs such as AES, DES / 3-DES and even RSA (for PIN encryption for instance). The circuit requires a single 6MHz to 12MHz crystal. The respective 73S1210F embedded memories are 32KB Flash program memory, 2KB user XRAM memory, and 256B IRAM memory. Dedicated FIFOs for the ISO 7816 UART are independent from the user XRAM and IRAM. Alternatively to the turnkey firmware offered by Teridian, customers can develop their own embedded firmware directly within their application or using Teridian 73S1210F Evaluation Board through a JTAG-like interface. The chip incorporates an inductor-based DC-DC converter that generates all the necessary voltages to the various 73S1210F function blocks (smart card interface, digital core, etc.) from any of two distinct power supply sources: the +5V bus (VBUS, 4.4 to 6.5V), or a main battery (VBAT, 4.0V to 6.5V). The chip automatically powers-up the DCDC converter with VBUS if it is present, or uses VBAT as the supply input if VBUS is not present. Alternatively, the pin VPC can support a wider power supply input range (2.7V to 6.5V), when using a single system supply source. Rev. 1.4 In addition, the circuit features an ON/OFF mode which operates directly with an ON/OFF system switch: Any activity on the ON/OFF button is debounced internally and controls the power generation circuit accordingly, under the supervision of the firmware (OFF request / OFF acknowledgement at firmware level). The OFF mode can be alternatively initiated from the controller (firmware action instead of ON/OFF switch). In OFF mode, the circuit typically draws less than 1A, which makes it ideal for applications where battery life must be maximized. Embedded Flash memory is in-system programmable and lockable by means of on-silicon fuses. This makes the 73S1210F suitable for both development and production phases. Teridian Semiconductor Corporation offers with its 73S1210F a very comprehensive set of software libraries for EMV. Refer to the 73S12xxF Software User's Guide for a complete description of the Application Programming Interface (API Libraries) and related software modules. A complete array of development and programming tools, libraries and demonstration boards enable rapid development and certification of readers that meet most demanding smart card standards. APPLICATIONS * * * * PINpad smart card readers: o With serial connectivity o Ideal for low-cost POS Terminals and Digital Identification (Secure Login, Gov't ID, ...) SIM Readers in Personal Wireless devices Payphones & Vending machines General purpose smart card readers ADVANTAGES * * * * * * * * * Reduced BOM Versatile power supply options o 2.7V to 6.5V ranges Higher performance CPU core (up to 24MIPS) Built-in EMV/ISO slot, expandable to multi-slots Flexible power supply options o On-chip DC-DC converter o CMOS switches between supply inputs Sub-A Power Down mode with ON/OFF switch Powerful In-Circuit Emulation and Programming A complete set of EMV4.1 / ISO7816 libraries Turnkey PC/SC firmware and host drivers o Multiple OS supported (c) 2009 Teridian Semiconductor Corporation 1 73S1210F Data Sheet DS_1210F_001 FEATURES 80515 Core: Communication Interfaces: * 1 clock cycle per instruction (most instructions) * * CPU clocked up to 24MHz Full-duplex serial interface (1200 to 115kbps UART) * 32KB Flash memory (lockable) * I2C Master Interface (400kbps) * 2kB XRAM (User Data Memory) * Man-Machine Interface and I/Os: * 256 byte IRAM * * Hardware watchdog timer 6x5 Keyboard (hardware scanning, debouncing and scrambling) * (8) User I/Os * Single programmable current output (LED) * Operating Voltage: * Single supply 2.7V to 6.5V operation (VPC) * 5V supply (VBUS 4.4V to 5.5V) with or without battery back up operation (VBAT 4.0V to 6.5V) * Automated detection of voltage presence - Priority on VBUS over VBAT Oscillators: * Single low-cost 6MHz to 12MHz crystal * An Internal PLL provides all the necessary clocks to each block of the system Interrupts: * Standard 80C515 4-priority level structure * 9 different sources of interrupt to the core Power Down Modes: DC-DC Converter: * 2 standard 80C515 Power Down and IDLE modes * Requires a single 10H Inductor * Sub-A OFF mode * 3.3V / 20mA supply available for external circuits * ON/OFF Main System Power Switch: Operating Temperature: * Input for an SPST momentary switch to ground * -40C to 85C Timers: Package: * (2) Standard 80C52 timers T0 and T1 * * (1) 16-bit timer Turnkey Firmware: Built-in ISO-7816 Card Interface: * Linear regulator produces VCC for the card (1.8V, 3V or 5V) 68-pin QFN, 44 pin QFN * Compliant with PC/SC, ISO7816 and EMV4.1 specifications * Features a Power Down mode accessible from the host * Full compliance with EMV 4.1 * Activation/Deactivation sequencers * Supports Plug & Play over serial interface * Auxiliary I/O lines (C4 and C8 signals) * (R) Windows XP driver available (*) * 7kV ESD protection on all interface pins * Windows CE / Mobile driver available (*) Communication with Smart Cards: * Linux and other OS: Upon request * ISO 7816 UART 9600 to 115kbps for T=0, T=1 * Or for custom developments: * (2) 2-Byte FIFOs for transmit and receive o * A complete set of ISO-7816, EMV4.1 and low-level libraries are available for T=0 / T=1 Configured to drive multiple external Teridian 73S8010x interfaces (for multi-SAM architectures) o Two-level Application Programming Interface (ANSI C-language libraries) Voltage Detection: * Analog Input (detection range: 1.0V to 2.5V) (*) Contact Teridian Semiconductor for conditions and availability. 2 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Table of Contents 1 Hardware Description ......................................................................................................................... 8 1.1 Pin Description ............................................................................................................................. 8 1.2 Hardware Overview ................................................................................................................... 11 1.3 80515 MPU Core ....................................................................................................................... 11 1.3.1 80515 Overview ............................................................................................................. 11 1.3.2 Memory Organization .................................................................................................... 11 1.4 Program Security ....................................................................................................................... 16 1.5 Special Function Registers (SFRs) ........................................................................................... 18 1.5.1 Internal Data Special Function Registers (SFRs).......................................................... 18 1.5.2 IRAM Special Function Registers (Generic 80515 SFRs) ............................................ 19 1.5.3 External Data Special Function Registers (SFRs) ........................................................ 20 1.6 Instruction Set ............................................................................................................................ 22 1.7 Peripheral Descriptions .............................................................................................................. 22 1.7.1 Oscillator and Clock Generation .................................................................................... 22 1.7.2 Power Supply Management .......................................................................................... 25 1.7.3 Power ON/OFF .............................................................................................................. 26 1.7.4 Power Control Modes .................................................................................................... 27 1.7.5 Interrupts ........................................................................................................................ 33 1.7.6 UART ............................................................................................................................. 40 1.7.7 Timers and Counters ..................................................................................................... 45 1.7.8 WD Timer (Software Watchdog Timer) ......................................................................... 47 1.7.9 User (USR) Ports ........................................................................................................... 49 1.7.10 Analog Voltage Comparator .......................................................................................... 51 1.7.11 LED Driver ..................................................................................................................... 53 1.7.12 I2C Master Interface ....................................................................................................... 54 1.7.13 Keypad Interface ............................................................................................................ 61 1.7.14 Emulator Port ................................................................................................................. 68 1.7.15 Smart Card Interface Function ...................................................................................... 69 1.7.16 VDD Fault Detect Function .......................................................................................... 103 2 Typical Application Schematic ...................................................................................................... 104 3 Electrical Specification................................................................................................................... 105 3.1 Absolute Maximum Ratings ..................................................................................................... 105 3.2 Recommended Operating Conditions ..................................................................................... 105 3.3 Digital IO Characteristics ......................................................................................................... 106 3.4 Oscillator Interface Requirements ........................................................................................... 107 3.5 DC Characteristics: Analog Input............................................................................................. 107 3.6 Smart Card Interface Requirements ........................................................................................ 108 3.7 DC Characteristics ................................................................................................................... 110 3.8 Current Fault Detection Circuits............................................................................................... 111 4 Equivalent Circuits ......................................................................................................................... 112 5 Package Pin Designation ............................................................................................................... 120 5.1 68-pin QFN Pinout ................................................................................................................... 120 5.2 44-pin QFN Pinout ................................................................................................................... 121 6 Packaging Information ................................................................................................................... 122 6.1 68-Pin QFN Package Outline .................................................................................................. 122 6.2 44-Pin QFN Package Outline .................................................................................................. 123 7 Ordering Information ...................................................................................................................... 124 8 Related Documentation .................................................................................................................. 124 9 Contact Information ........................................................................................................................ 124 Revision History ...................................................................................................................................... 125 Rev. 1.4 3 73S1210F Data Sheet DS_1210F_001 Figures Figure 1: IC Functional Block Diagram ......................................................................................................... 7 Figure 2: Memory Map ................................................................................................................................ 15 Figure 3: Clock Generation and Control Circuits ........................................................................................ 22 Figure 4: Oscillator Circuit ........................................................................................................................... 24 Figure 5: Detailed Power Management Logic Block Diagram .................................................................... 25 Figure 6: Power Down Control .................................................................................................................... 27 Figure 7: Detail of Power Down Interrupt Logic .......................................................................................... 28 Figure 8: Power Down Sequencing ............................................................................................................ 29 Figure 9: External Interrupt Configuration ................................................................................................... 33 Figure 10: I2C Write Mode Operation .......................................................................................................... 55 Figure 11: I2C Read Operation ................................................................................................................... 56 Figure 12: Simplified Keypad Block Diagram ............................................................................................. 61 Figure 13: Keypad Interface Flow Chart ..................................................................................................... 63 Figure 14: Smart Card Interface Block Diagram ......................................................................................... 69 Figure 15: External Smart Card Interface Block Diagram .......................................................................... 70 Figure 16: Asynchronous Activation Sequence Timing .............................................................................. 73 Figure 17: Deactivation Sequence .............................................................................................................. 73 Figure 18: Smart Card CLK and ETU Generation ...................................................................................... 74 Figure 19: Guard, Block, Wait and ATR Time Definitions .......................................................................... 75 Figure 20: Synchronous Activation ............................................................................................................. 77 Figure 21: Example of Sync Mode Operation: Generating/Reading ATR Signals ..................................... 77 Figure 22: Creation of Synchronous Clock Start/Stop Mode Start Bit in Sync Mode ................................. 78 Figure 23: Creation of Synchronous Clock Start/Stop Mode Stop Bit in Sync Mode ................................. 78 Figure 24: Operation of 9-bit Mode in Sync Mode ...................................................................................... 79 Figure 25: 73S1210F Typical Application Schematic ............................................................................... 104 Figure 26: 12 MHz Oscillator Circuit ......................................................................................................... 112 Figure 27: 32KHz Oscillator Circuit ........................................................................................................... 112 Figure 28: Digital I/O Circuit ...................................................................................................................... 113 Figure 29: Digital Output Circuit ................................................................................................................ 113 Figure 30: Digital I/O with Pull Up Circuit .................................................................................................. 114 Figure 31: Digital I/O with Pull Down Circuit ............................................................................................. 114 Figure 32: Digital Input Circuit ................................................................................................................... 115 Figure 33: OFF_REQ Interface Circuit ..................................................................................................... 115 Figure 34: Keypad Row Circuit ................................................................................................................. 115 Figure 35: Keypad Column Circuit ............................................................................................................ 116 Figure 36: LED Circuit ............................................................................................................................... 116 Figure 37: Test and Security Pin Circuit ................................................................................................... 117 Figure 38: Analog Input Circuit ................................................................................................................. 117 Figure 39: Smart Card Output Circuit ....................................................................................................... 117 Figure 40: Smart Card I/O Circuit ............................................................................................................. 118 Figure 41: PRES Input Circuit ................................................................................................................... 118 Figure 42: PRESB Input Circuit ................................................................................................................ 118 Figure 43: ON_OFF Input Circuit .............................................................................................................. 119 Figure 44: 73S1210F 68 QFN Pinout ....................................................................................................... 120 Figure 45: 73S1210F 44 QFN Pinout ....................................................................................................... 121 Figure 46: 73S1210F 68 QFN Mechanical Drawing ................................................................................. 122 Figure 47: 73S1210F 44 QFN Package Drawing ..................................................................................... 123 4 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Tables Table 1: 73S1210 Pinout Description ........................................................................................................... 8 Table 2: MPU Data Memory Map ............................................................................................................... 11 Table 3: Flash Special Function Registers ................................................................................................. 13 Table 4: Internal Data Memory Map ........................................................................................................... 14 Table 5: Program Security Registers .......................................................................................................... 17 Table 6: IRAM Special Function Registers Locations ................................................................................ 18 Table 7: IRAM Special Function Registers Reset Values .......................................................................... 19 Table 8: XRAM Special Function Registers Reset Values ......................................................................... 20 Table 9: PSW Register................................................................................................................................ 21 Table 10: Port Registers ............................................................................................................................. 21 Table 11: Frequencies and Mcount Values for MCLK = 96MHz ................................................................ 23 Table 12: The MCLKCtl Register ................................................................................................................ 23 Table 13: The TCON Register .................................................................................................................... 24 Table 14: The INT5Ctl Register .................................................................................................................. 30 Table 15: The MISCtl0 Register.................................................................................................................. 30 Table 16: The MISCtl1 Register.................................................................................................................. 31 Table 17: The MCLKCtl Register ................................................................................................................ 31 Table 18: The PCON Register .................................................................................................................... 32 Table 19: The IEN0 Register ...................................................................................................................... 34 Table 20: The IEN1 Register ...................................................................................................................... 35 Table 21: The IEN2 Register ...................................................................................................................... 35 Table 22: The TCON Register .................................................................................................................... 36 Table 23: The T2CON Register .................................................................................................................. 36 Table 24: The IRCON Register ................................................................................................................... 37 Table 25: External MPU Interrupts.............................................................................................................. 37 Table 26: Control Bits for External Interrupts .............................................................................................. 38 Table 27: Priority Level Groups .................................................................................................................. 38 Table 28: The IP0 Register ......................................................................................................................... 38 Table 29: The IP1 Register ......................................................................................................................... 39 Table 30: Priority Levels.............................................................................................................................. 39 Table 31: Interrupt Polling Sequence.......................................................................................................... 39 Table 32: Interrupt Vectors ......................................................................................................................... 39 Table 33: UART Modes .............................................................................................................................. 40 Table 34: Baud Rate Generation ................................................................................................................ 40 Table 35: The PCON Register .................................................................................................................... 41 Table 36: The BRCON Register ................................................................................................................. 41 Table 37: The MISCtl0 Register.................................................................................................................. 42 Table 38: The S0CON Register .................................................................................................................. 43 Table 39: The S1CON Register .................................................................................................................. 44 Table 40: The TMOD Register .................................................................................................................... 45 Table 41: Timers/Counters Mode Description ............................................................................................ 45 Table 42: The TCON Register .................................................................................................................... 46 Table 43: The IEN0 Register ...................................................................................................................... 47 Table 44: The IEN1 Register ...................................................................................................................... 48 Table 45: The IP0 Register ......................................................................................................................... 48 Table 46: The WDTREL Register ............................................................................................................... 48 Table 47: Direction Registers and Internal Resources for DIO Pin Groups ............................................... 49 Table 48: UDIR Control Bit ......................................................................................................................... 49 Table 49: Selectable Controls Using the UxIS Bits..................................................................................... 49 Table 50: The USRIntCtl1 Register ............................................................................................................ 50 Table 51: The USRIntCtl2 Register ............................................................................................................ 50 Table 52: The USRIntCtl3 Register ............................................................................................................ 50 Table 53: The USRIntCtl4 Register ............................................................................................................ 50 Table 54: The ACOMP Register ................................................................................................................. 51 Table 55: The INT6Ctl Register .................................................................................................................. 52 Table 56: The LEDCtl Register ................................................................................................................... 53 Rev. 1.4 5 73S1210F Data Sheet DS_1210F_001 Table 57: The DAR Register ....................................................................................................................... 57 Table 58: The WDR Register ...................................................................................................................... 57 Table 59: The SWDR Register ................................................................................................................... 58 Table 60: The RDR Register....................................................................................................................... 58 Table 61: The SRDR Register .................................................................................................................... 59 Table 62: The CSR Register ....................................................................................................................... 59 Table 63: The INT6Ctl Register .................................................................................................................. 60 Table 64: The KCOL Register..................................................................................................................... 64 Table 65: The KROW Register ................................................................................................................... 64 Table 66: The KSCAN Register .................................................................................................................. 65 Table 67: The KSTAT Register ................................................................................................................... 65 Table 68: The KSIZE Register .................................................................................................................... 66 Table 69: The KORDERL Register ............................................................................................................. 67 Table 70: The KORDERH Register ............................................................................................................ 67 Table 71: The INT5Ctl Register .................................................................................................................. 68 Table 72: The SCSel Register .................................................................................................................... 80 Table 73: The SCInt Register ..................................................................................................................... 81 Table 74: The SCIE Register ...................................................................................................................... 82 Table 75: The VccCtl Register .................................................................................................................... 83 Table 76: The VccTmr Register .................................................................................................................. 84 Table 77: The CRDCtl Register .................................................................................................................. 85 Table 78: The STXCtl Register ................................................................................................................... 86 Table 79: The STXData Register ................................................................................................................ 87 Table 80: The SRXCtl Register ................................................................................................................... 87 Table 81: The SRXData Register ............................................................................................................... 88 Table 82: The SCCtl Register ..................................................................................................................... 89 Table 83: The SCECtl Register ................................................................................................................... 90 Table 84: The SCDIR Register ................................................................................................................... 91 Table 85: The SPrtcol Register ................................................................................................................... 92 Table 86: The SCCLK Register .................................................................................................................. 93 Table 87: The SCECLK Register ................................................................................................................ 93 Table 88: The SParCtl Register .................................................................................................................. 94 Table 89: The SByteCtl Register ................................................................................................................ 95 Table 90: The FDReg Register ................................................................................................................... 96 Table 91: The FDReg Bit Functions............................................................................................................ 96 Table 92: Divider Ratios Provided by the ETU Counter ............................................................................. 96 Table 93: Divider Values for the ETU Clock ............................................................................................... 97 Table 94: The CRCMsB Register ............................................................................................................... 98 Table 95: The BGT Register ....................................................................................................................... 99 Table 96: The EGT Register ....................................................................................................................... 99 Table 97: The BWTB0 Register ................................................................................................................ 100 Table 98: The BWTB1 Register ................................................................................................................ 100 Table 99: The BWTB2 Register ................................................................................................................ 100 Table 100: The BWTB3 Register .............................................................................................................. 100 Table 101: The CWTB0 Register .............................................................................................................. 100 Table 102: The CWTB1 Register .............................................................................................................. 100 Table 103: The ATRLsB Register ............................................................................................................. 101 Table 104: The ATRMsB Register ............................................................................................................ 101 Table 105: The STSTO Register .............................................................................................................. 101 Table 106: The RLength Register ............................................................................................................. 101 Table 107: Smart Card SFR Table ........................................................................................................... 102 Table 108: The VDDFCtl Register ............................................................................................................ 103 Table 109: Order Numbers and Packaging Marks ................................................................................... 124 6 Rev. 1.4 VBAT VBUS VP LIN VPC TBUS0 TBUS1 TBUS2 TBUS3 RXTX ERST ISBR TCLK ANA_IN SEC GND RESET GND 73S1210F Data Sheet TEST DS_1210F_001 ON_OFF ICE INTERFACE VDD PLL and TIMEBASES POWER REGULATION AND VCC CONTROL LOGIC VOLTAGE REFERENCE AND FUSE TRIM CIRCUITRY VPD REGULATOR 12MHz OSCILLATOR VCC RST CLK VDD OCDSI ROW0 ROW1 ROW2 ROW3 KEYPAD INTERFACE FLASH INTERFACE MEMORY_ CONTROL CONTROL UNIT RAM_ SFR_ CONTROL TIMER_0_1 SCRATCH IRAM 256B CORE SMART CARD ISO INTERFACE SMART CARD LOGIC ISO UART and CLOCK GENERATOR FLASH/ROM PROGRAM MEMORY 32KB GND ROW4 ROW5 COL0 COL1 COL2 COL3 COL4 VDD GND X12IN X12OUT OFF_REQ AUX1 AUX2 PRES EXTERNAL SMART CARD INTERFACE ALU SCLK SIO WATCHDOG TIMER PMU DATA XRAM 2KB I/O INT2 PORTS ISR INT3 SERIAL 2 IC MASTER INT. USR(8:0) DRIVERS USR0 USR1 USR2 USR3 USR4 USR5 USR6 USR7 SCL SDA PERIPHERAL INTERFACE and SFR LOGIC LED0 TXD RXD Pins available on both 68 and 44-pin packages. GND LED DRIVER Pins only available on 68-pin package. Figure 1: IC Functional Block Diagram Rev. 1.4 7 73S1210F Data Sheet DS_1210F_001 1 Hardware Description 1.1 Pin Description Pin Name Pin (68 QFN) Pin (44 QFN) Type Equivalent Circuit* Table 1: 73S1210 Pinout Description X12IN 10 9 I Figure 26 MPU clock crystal oscillator input pin. A 1M resistor is required between pins X12IN and X12OUT. X12OUT 11 10 O Figure 26 MPU clock crystal oscillator output pin. ROW(5:0) 0 1 2 3 4 5 I Figure 34 Keypad row input sense. 21 22 24 33 36 37 O Figure 35 Keypad column output scan pins. COL(4:0) 0 1 2 3 4 USR(7:0) 0 1 2 3 4 5 6 7 Description 12 13 14 16 19 35 34 32 31 30 29 23 20 IO Figure 30 General-purpose user pins, individually configurable as inputs or outputs or as external input interrupt ports. O Figure 29 I2C (master mode) compatible Clock signal. Note: the pin is configured as an open drain output. When the I2C interface is being used, an external pull up resistor is required. A value of 3K is recommended. SCL 5 22 21 20 19 18 17 14 13 6 SDA 6 7 IO Figure 28 I2C (master mode) compatible data I/O. Note: this pin is bidirectional. When the pin is configured as output, it is an open drain output. When the I2C interface is being used, an external pull up resistor is required. A value of 3K is recommended. RXD 17 11 I Figure 32 Serial UART Receive data pin. TXD 18 12 O Figure 29 Serial UART Transmit data pin. INT3 48 30 I Figure 32 General purpose interrupt input. INT2 49 31 I Figure 32 General purpose interrupt input. SIO 47 29 IO Figure 28 IO data signal for use with external Smart Card interface circuit such as 73S8010. SCLK 45 28 O Figure 29 Clock signal for use with external Smart Card interface circuit. 8 Rev. 1.4 Pin Name Pin (44 QFN) Type Equivalent Circuit* 73S1210F Data Sheet Pin (68 QFN) DS_1210F_001 PRES 53 34 I Figure 41 Smart Card presence. Active high. Note: the pin has a very weak pull down resistor. In noisy environments, an external pull down may be desired to insure against a false card event. CLK 55 36 O Figure 39 Smart Card clock signal. RST 57 38 O Figure 39 Smart Card reset signal. IO 61 42 IO Figure 40 Smart Card Data IO signal. AUX1 60 41 IO Figure 40 Auxiliary Smart Card IO signal (C4). AUX2 59 40 IO Figure 40 Auxiliary Smart Card IO signal (C8). VCC 58 39 PSO Smart Card VCC supply voltage output. A 0.47F capacitor is required and should be located at the smart card connector. The capacitor should be a ceramic type with low ESR. GND 56 37 GND Smart Card Ground. VPC 65 44 PSI Power supply source for main voltage converter circuit. A 10F and a 0.1F capacitor are required at the VPC input. The 10F capacitor should be a ceramic type with low ESR. VBUS 62 PSI Alternate power source input from external power supply. VBAT 64 PSI Alternate power source input, typically from two series cells, V > 4V. VP 54 35 PSO Intermediate output of main converter circuit. Requires an external 4.7F low ESR filter capacitor to GND. LIN 66 1 PSI Connection to 10H inductor for internal step up converter. Note: inductor must be rated for 400 mA maximum peak current. ON_OFF 63 43 I Figure 43 Power control pin. Connected to normally open SPST switch to ground. Closing switch for duration greater than debounce period will turn 73S1210F on. If 73S1210F is on, closing switch will flag the 73S1210F to go to the off state. Firmware will control when the power is shut down. OFF_REQ 52 33 O Figure 33 Digital output. If ON_OFF switch is closed (to ground) for debounce duration and circuit is "on," OFF_REQ will go high (Request to turn OFF). This output should be connected to an interrupt pin to signal the CPU core that a request to shut down power has been initiated. The firmware can then perform all of its shut down housekeeping duties before shutting down VDD. TBUS(3:0) 0 1 2 3 Rev. 1.4 IO Description Trace bus signals for ICE. 50 46 44 41 9 Type RXTX 43 27 IO ICE control. ERST 38 23 IO ICE control. ISBR 3 IO ICE control. TCLK 39 I ICE control. ANA_IN 15 AI Figure 38 Analog input pin. This signal goes to a programmable comparator and is used to sense the value of an external voltage. SEC 2 I Figure 37 Input pin for use in programming security fuse. It should be connected to ground when not in use. TEST 51 32 DI Figure 37 Test pin, should be connected to ground LED0 4 5 IO Figure 36 Special output driver, programmable pull-down current to drive LED. May also be used as an input. VDD 68 28 40 3 16 25 PSO N/C 7 8 26 27 GND 9 25 42 67 2 8 15 26 GND RESET 1 4 I 24 Equivalent Circuit* Pin Name Pin (44 QFN) DS_1210F_001 Pin (68 Qfn) 73S1210F Data Sheet Description VDD supply output pin. A 0.1F capacitor is recommended at each VDD pin. No connect. General ground supply pins for all IO and logic circuits. Figure 32 Reset input, positive assertion. Resets logic and registers to default condition. Note: to insure proper reset operation after VDD is turned on by application of VBUS power or activation of the ON/OFF switch, external reset circuitry must generate a proper reset signal to the 73S1210F. This can be accomplished via a simple RC network. * See the figures in the Equivalent Circuits section. 10 Rev. 1.4 DS_1210F_001 1.2 73S1210F Data Sheet Hardware Overview The 73S1210F single smart card controller integrates all primary functional blocks required to implement a smart card reader. Included on chip are an 8051-compatible microprocessor (MPU) which executes up to one instruction per clock cycle (80515), a fully integrated IS0 7816 compliant smart card interface, expansion smart card interface, serial interface, I2C interface, 6 x 5 keypad interface, RAM, FLASH memory, and a variety of I/O pins. The power management circuitry provides a 3.3V voltage output (VDD, pin #68) that must be connected to the power supply inputs of the digital core of the circuit, pins # 28 and 40 (these are not internally connected). Should external circuitry require a 3.3V digital power supply, the VDD output is capable of supplying additional current. Figure 1 shows a functional block diagram of the 73S1210F. 1.3 80515 MPU Core 1.3.1 80515 Overview The 73S1210F includes an 80515 MPU (8-bit, 8051-compatible) that performs most instructions in one clock cycle. The 80515 architecture eliminates redundant bus states and implements parallel execution of fetch and execution phases. Normally a machine cycle is aligned with a memory fetch, therefore, most of the 1-byte instructions are performed in a single cycle. This leads to an 8x performance (average) improvement (in terms of MIPS) over the Intel 8051 device running at the same clock frequency. Actual processor clocking speed can be adjusted to the total processing demand of the application (cryptographic calculations, key management, memory management, and I/O management) using the XRAM special function register MPUCKCtl. Typical smart card, serial, keyboard and I2C management functions are available for the MPU as part of the Teridian standard library. A standard ANSI "C" 80515-application programming interface library is available to help reduce design cycle. Refer to the 73S12xxF Software User's Guide. 1.3.2 Memory Organization The 80515 MPU core incorporates the Harvard architecture with separate code and data spaces. Memory organization in the 80515 is similar to that of the industry standard 8051. There are three memory areas: Program memory (Flash), external data memory (XRAM), and internal data memory (IRAM). Data bus address space is allocated to on-chip memory as shown Table 2 Table 2: MPU Data Memory Map Address (hex) Memory Technology Memory Type Typical Usage Memory Size (bytes) 0000-7FFF Flash Memory Non-volatile Program and non-volatile data 32KB 0000-07FF Static RAM Volatile MPU data XRAM 2KB FC00-FFFF External SFR Volatile Peripheral control 1KB Note: The IRAM is part of the core and is addressed differently. Program Memory: The 80515 can address up to 32KB of program memory space from 0x0000 to 0xFFFF. Program memory is read when the MPU fetches instructions or performs a MOVC operation. After reset, the MPU starts program execution from location 0x0000. The lower part of the program memory includes reset and interrupt vectors. The interrupt vectors are spaced at 8-byte intervals, starting from 0x0003. Reset is located at 0x0000. Flash Memory: The program memory consists of flash memory. The flash memory is intended to primarily contain MPU program code. Flash erasure is initiated by writing a specific data pattern to Rev. 1.4 11 73S1210F Data Sheet DS_1210F_001 specific SFR registers in the proper sequence. These special pattern/sequence requirements prevent inadvertent erasure of the flash memory. The mass erase sequence is: 1. Write 1 to the FLSH_MEEN bit in the FLSHCTL register (SFR address 0xB2[1]). 2. Write pattern 0xAA to ERASE (SFR address 0x94). Note: The mass erase cycle can only be initiated when the ICE port is enabled. The page erase sequence is: 1. Write the page address to PGADDR (SFR address 0xB7[7:1]). 2. Write pattern 0x55 to ERASE (SFR address 0x94). The PGADDR register denotes the page address for page erase. The page size is 512 (200h) bytes and there are 128 pages within the flash memory. The PGADDR denotes the upper seven bits of the flash memory address such that bit 7:1 of the PGADDR corresponds to bit 15:9 of the flash memory address. Bit 0 of the PGADDR is not used and is ignored. The MPU may write to the flash memory. This is one of the non-volatile storage options available to the user. The FLSHCTL SFR bit FLSH_PWE (flash program write enable) differentiates 80515 data store instructions (MOVX@DPTR,A) between Flash and XRAM writes. Before setting FLSH_PWE, all interrupts need to be disabled by setting EAL = 1. Table 3 shows the location and description of the 73S1210 flash-specific SFRs. Any flash modifications must set the CPUCLK to operate at 3.6923 MHz (MPUCLKCtl = 0x0C) before any flash memory operations are executed to insure the proper timing when modifying the flash memory. 12 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Table 3: Flash Special Function Registers Register ERASE SFR Address R/W 0x94 W Description This register is used to initiate either the Flash Mass Erase cycle or the Flash Page Erase cycle. Specific patterns are expected for ERASE in order to initiate the appropriate Erase cycle (default = 0x00). 0x55 - Initiate Flash Page Erase cycle. Must be proceeded by a write to PGADDR @ SFR 0xB7. 0xAA - Initiate Flash Mass Erase cycle. Must be proceeded by a write to FLSH_MEEN @ SFR 0xB2 and the debug port must be enabled. Any other pattern written to ERASE will have no effect. PGADDR 0xB7 R/W Flash Page Erase Address register containing the flash memory page address (page 0 through 127) that will be erased during the Page Erase cycle (default = 0x00). Note: the page address is shifted left by one bit (see detailed description above). Must be re-written for each new Page Erase cycle. FLSHCTL 0xB2 R/W Bit 0 (FLSH_PWE): Program Write Enable: 0 - MOVX commands refer to XRAM Space, normal operation (default). 1 - MOVX @DPTR,A moves A to Program Space (Flash) @ DPTR. This bit is automatically reset after each byte written to flash. Writes to this bit are inhibited when interrupts are enabled. W Bit 1 (FLSH_MEEN): Mass Erase Enable: 0 - Mass Erase disabled (default). 1 - Mass Erase enabled. Must be re-written for each new Mass Erase cycle. R/W Bit 6 (SECURE): Enables security provisions that prevent external reading of flash memory and CE program RAM. This bit is reset on chip reset and may only be set. Attempts to write zero are ignored. Internal Data Memory: The Internal data memory provides 256 bytes (0x00 to 0xFF) of data memory. The internal data memory address is always one byte wide and can be accessed by either direct or indirect addressing. The Special Function Registers occupy the upper 128 bytes. This SFR area is available only by direct addressing. Indirect addressing accesses the upper 128 bytes of Internal RAM. The lower 128 bytes contain working registers and bit-addressable memory. The lower 32 bytes form four banks of eight registers (R0-R7). Two bits on the program memory status word (PSW) select which bank is in use. The next 16 bytes form a block of bit-addressable memory space at bit addresses 0x000x7F. All of the bytes in the lower 128 bytes are accessible through direct or indirect addressing. Table 4 shows the internal data memory map. Rev. 1.4 13 73S1210F Data Sheet DS_1210F_001 Table 4: Internal Data Memory Map Address 0xFF 0x80 0x7F 0x30 0x2F 0x20 0x1F 0x00 Direct Addressing Special Function Registers (SFRs) Indirect Addressing RAM Byte-addressable area Byte or bit-addressable area Register banks R0...R7 (x4) External Data Memory: While the 80515 can address up to 64KB of external data memory in the space from 0x0000 to 0xFFFF, only the memory ranges shown in Figure 2 contain physical memory. The 80515 writes into external data memory when the MPU executes a MOVX @Ri,A or MOVX @DPTR,A instruction. The MPU reads external data memory by executing a MOVX A,@Ri or MOVX A,@DPTR instruction. There are two types of instructions, differing in whether they provide an eight-bit or sixteen-bit indirect address to the external data RAM. In the first type (MOVX A,@Ri), the contents of R0 or R1, in the current register bank, provide the eight lower-ordered bits of address. This method allows the user access to the first 256 bytes of the 2KB of external data RAM. In the second type of MOVX instruction (MOVX A,@DPTR), the data pointer generates a sixteen-bit address. 14 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Address Use 0xFFFF Peripheral Control Registers (128b) 0XFF80 0xFF7F 0XFE00 Address Use Smart Card Control (384b) 0xFBFF 0x7FFF - 0x0800 Address 0x07FF 0xFF 0x80 Use Indirect Access Direct Access Byte RAM SFRs 0x7F Byte RAM 0x48 Flash Program Memory 32K Bytes 0x47 Bit/Byte RAM 0x20 XRAM 0x1F Register bank 3 0x18 0x17 Register bank 2 0x10 0x0F Register bank 1 0x08 0x07 0x0000 0x0000 Program Memory Register bank 0 0x00 External Data Memory Internal Data Memory Figure 2: Memory Map Dual Data Pointer: The Dual Data Pointer accelerates the block moves of data. The standard DPTR is a 16-bit register that is used to address external memory. In the 80515 core, the standard data pointer is called DPTR, the second data pointer is called DPTR1. The data pointer select bit chooses the active pointer. The data pointer select bit is located at the LSB of the DPS IRAM special function register (DPS.0). DPTR is selected when DPS.0 = 0 and DPTR1 is selected when DPS.0 = 1. The user switches between pointers by toggling the LSB of the DPS register. All DPTR-related instructions use the currently selected DPTR for any activity. The second data pointer may not be supported by certain compilers. Rev. 1.4 15 73S1210F Data Sheet 1.4 DS_1210F_001 Program Security Two levels of program and data security are available. Each level requires a specific fuse to be blown in order to enable or set the specific security mode. Mode 0 security is enabled by setting the SECURE bit (bit 6 of SFR register FLSHCTL 0xB2). Mode 0 limits the ICE interface to only allow bulk erase of the flash program memory. All other ICE operations are blocked. This guarantees the security of the user's MPU program code. Security (Mode 0) is enabled by MPU code that sets the SECURE bit. The MPU code must execute the setting of the SECURE bit immediately after a reset to properly enable Mode 0. This should be the first instruction after the reset vector jump has been executed. If the "startup.a51" assembly file is used in an application, then it must be modified to set the SECURE bit after the reset vector jump. If not using "startup.a51", then this should be the first instruction in main(). Once security Mode 0 is enabled, the only way to disable it is to perform a global erase of the flash followed by a full circuit reset. Once the flash has been erased and the reset has been executed, security Mode 0 is disabled and the ICE has full control of the core. The flash can be reprogrammed after the bulk erase operation is completed. Global erase of the flash will also clear the data XRAM memory. The security enable bit (SECURE) is reset whenever the MPU is reset. Hardware associated with the bit only allows it to be set. As a result, the code may set the SECURE bit to enable the security Mode 0 feature but may not reset it. Once the SECURE bit is set, the code is protected and no external read of program code in flash or data (in XRAM) is possible. In order to invoke the security Mode 0, the SECSET0 (bit 1 of the XRAM SFR register SECReg 0xFFD7) fuse must be blown beforehand or the security mode 0 will not be enabled. The SECSET0 and SECSET1 fuses once blown, cannot be overridden. Specifically, when SECURE is set: * * * The ICE is limited to bulk flash erase only. Page zero of flash memory, the preferred location for the user's preboot code, may not be pageerased by either MPU or ICE. Page zero may only be erased with global flash erase. Note that global flash erase erases XRAM whether the SECURE bit is set or not. Writes to page zero, whether by MPU or ICE, are inhibited. Security mode 1 is in effect when the SECSET1 fuse has been programmed (blown open). In security mode 1, the ICE is completely and permanently disabled. The Flash program memory and the MPU are not available for alteration, observation, nor control. As soon as the fuse has been blown, the ICE is disabled. The testing of the SECSET1 fuse will occur during the reset and before the start of pre-boot and boot cycles. This mode is not reversible, nor recoverable. In order to blow the SECSET1 fuse, the SEC pin must be held high for the fuse burning sequence to be executed properly. The firmware can check to see if this pin is held high by reading the SECPIN bit (bit 5 of XRAM SFR register SECReg 0xFFD7). If this bit is set and the firmware desires, it can blow the SECSET1 fuse. The burning of the SECSET0 does not require the SEC pin to be held high. In order to blow the fuse for SECSET1 and SECSET0, a particular set of register writes in a specific order need to be followed. There are two additional registers that need to have a specific value written to them in order for the desired fuse to be blown. These registers are FUSECtl (0xFFD2) and TRIMPCtl (0xFFD1). The sequence for blowing the fuse is as follows: 1. Write 0x54H to FUSECtl. 2. Write 0x81H for security mode 0. Note: only program one security mode at a time. Write 0x82H for security mode 1. Note: SEC pin must be high for security mode 1. 3. Write 0xA6 to TRIMPCtl. 4. Delay about 500 s. 5. Write 0x00 to TRIMPCtl and FUSECtl. 16 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Table 5: Program Security Registers Register SFR Address R/W Description FLSHCTL 0xB2 R/W Bit 0 (FLSH_PWE): Program Write Enable: 0 - MOVX commands refer to XRAM Space, normal operation (default). 1 - MOVX @DPTR,A moves A to Program Space (Flash) @ DPTR. This bit is automatically reset after each byte written to flash. Writes to this bit are inhibited when interrupts are enabled. W Bit 1 (FLSH_MEEN): Mass Erase Enable: 0 - Mass Erase disabled (default). 1 - Mass Erase enabled. Must be re-written for each new Mass Erase cycle. R/W Bit 6 (SECURE): Enables security provisions that prevent external reading of flash memory and CE program RAM. This bit is reset on chip reset and may only be set. Attempts to write zero are ignored. TRIMPCtl 0xFFD1 W 0x54 value will set up for security fuse control. All other values are reserved and should not be used. FUSECtl 0xFFD2 W 0xA6 value will cause the selected fuse to be blown. All other values will stop the burning process. SECReg 0xFFD7 W Bit 7 (PARAMSEC): 0 - Normal operation. 1 - Enable permanent programming of the security fuses. R Bit 5 (SECPIN): Indicates the state of the SEC pin. The SEC pin is held low by a pull-down resistor. The user can force this pin high during boot sequence time to indicate to firmware that sec mode 1 is desired. R/W Bit 1 (SECSET1): See the Program Security section. R/W Bit 0 (SECSET0): See the Program Security section. Rev. 1.4 17 73S1210F Data Sheet 1.5 DS_1210F_001 Special Function Registers (SFRs) The 73S1210F utilizes numerous SFRs to communicate with the 73S1210Fs many peripherals. This results in the need for more SFR locations outside the direct address IRAM space (0x80 to 0xFF). While some peripherals are mapped to unused IRAM SFR locations, additional SFRs for the smart card and other peripheral functions are mapped to the top of the XRAM data space (0xFC00 to 0xFFFF). 1.5.1 Internal Data Special Function Registers (SFRs) A map of the Special Function Registers is shown in Table 6. Table 6: IRAM Special Function Registers Locations Hex\Bin F8 F0 E8 E0 D8 D0 C8 C0 B8 B0 A8 A0 98 90 88 80 X000 X001 X010 X011 X100 X101 KCOL KROW KSCAN KSTAT KSIZE X110 X111 B A BRCON PSW T2CON IRCON IEN1 IP1 IEN0 IP0 S0CON USR70 TCON S0BUF UDIR70 TMOD SP KORDERL KORDERH S0RELH S1RELH FLSHCTL S0RELL IEN2 DPS TL0 DPL S1CON TL1 DPH PGADDR S1BUF S1RELL ERASE TH0 TH1 DPL1 DPH1 WDTREL MCLKCtl PCON Bin/ Hex FF F7 EF E7 DF D7 CF C7 BF B7 AF A7 9F 97 8F 87 Only a few addresses are used, the others are not implemented. SFRs specific to the 73S1210F are shown in bold print (gray background). Any read access to unimplemented addresses will return undefined data, while most write access will have no effect. However, a few locations are reserved and not user configurable in the 73S1210F. Writes to the unused SFR locations can affect the operation of the core and therefore must not be written to. This applies to all the SFR areas in both the IRAM and XRAM spaces. In addition, all unused bit locations within valid SFR registers must be left in their default (power on default) states. 18 Rev. 1.4 DS_1210F_001 1.5.2 73S1210F Data Sheet IRAM Special Function Registers (Generic 80515 SFRs) Table 7 shows the location of the SFRs and the value they assume at reset or power-up. Table 7: IRAM Special Function Registers Reset Values Name Location Reset Value Description SP 0x81 0x07 Stack Pointer DPL 0x82 0x00 Data Pointer Low 0 DPH 0x83 0x00 Data Pointer High 0 DPL1 0x84 0x00 Data Pointer Low 1 DPH1 0x85 0x00 Data Pointer High 1 WDTREL 0x86 0x00 Watchdog Timer Reload register PCON 0x87 0x00 Power Control TCON 0x88 0x00 Timer/Counter Control TMOD 0x89 0x00 Timer Mode Control TL0 0x8A 0x00 Timer 0, low byte TL1 0x8B 0x00 Timer 1, high byte TH0 0x8C 0x00 Timer 0, low byte TH1 0x8D 0x00 Timer 1, high byte MCLKCtl 0x8F 0x0A Master Clock Control USR70 0x90 0xFF User Port Data (7:0) UDIR70 0x91 0xFF User Port Direction (7:0) DPS 0x92 0x00 Data Pointer Select Register ERASE 0x94 0x00 Flash Erase S0CON 0x98 0x00 Serial Port 0, Control Register S0BUF 0x99 0x00 Serial Port 0, Data Buffer IEN2 0x9A 0x00 Interrupt Enable Register 2 S1CON 0x9B 0x00 Serial Port 1, Control Register S1BUF 0x9C 0x00 Serial Port 1, Data Buffer S1RELL 0x9D 0x00 Serial Port 1, Reload Register, low byte IEN0 0xA8 0x00 Interrupt Enable Register 0 IP0 0xA9 0x00 Interrupt Priority Register 0 S0RELL 0xAA 0xD9 Serial Port 0, Reload Register, low byte FLSHCTL 0xB2 0x00 Flash Control PGADDR 0xB7 0x00 Flash Page Address IEN1 0xB8 0x00 Interrupt Enable Register 1 IP1 0xB9 0x00 Interrupt Priority Register 1 S0RELH 0xBA 0x03 Serial Port 0, Reload Register, high byte S1RELH 0xBB 0x03 Serial Port 1, Reload Register, high byte IRCON 0xC0 0x00 Interrupt Request Control Register T2CON 0xC8 0x00 Timer 2 Control PSW 0xD0 0x00 Program Status Word KCOL 0XD1 0x1F Keypad Column Rev. 1.4 19 73S1210F Data Sheet DS_1210F_001 Name Location Reset Value Description KROW 0XD2 0x3F Keypad Row KSCAN 0XD3 0x00 Keypad Scan Time KSTAT 0XD4 0x00 Keypad Control/Status KSIZE 0XD5 0x00 Keypad Size KORDERL 0XD6 0x00 Keypad Column LS Scan Order KORDERH 0XD7 0x00 Keypad Column MS Scan Order BRCON 0xD8 0x00 Baud Rate Control Register (only BRCON.7 bit used) A 0xE0 0x00 Accumulator B 0xF0 0x00 B Register 1.5.3 External Data Special Function Registers (SFRs) A map of the XRAM Special Function Registers is shown in Table 8. The smart card registers are listed separately in Table 107. Table 8: XRAM Special Function Registers Reset Values Name Location Reset Value Description DAR 0x FF80 0x00 Device Address Register (I2C) WDR 0x FF81 0x00 Write Data Register (I2C) SWDR 0x FF82 0x00 Secondary Write Data Register (I2C) RDR 0x FF83 0x00 Read Data Register (I2C) SRDR 0x FF84 0x00 Secondary Read Data Register (I2C) CSR 0x FF85 0x00 Control and Status Register (I2C) USRIntCtl1 0x FF90 0x00 External Interrupt Control 1 USRIntCtl2 0x FF91 0x00 External Interrupt Control 2 USRIntCtl3 0x FF92 0x00 External Interrupt Control 3 USRIntCtl4 0x FF93 0x00 External Interrupt Control 4 INT5Ctl 0x FF94 0x00 External Interrupt Control 5 INT6Ctl 0x FF95 0x00 External Interrupt Control 6 MPUCKCtl 0x FFA1 0x0C MPU Clock Control ACOMP 0x FFD0 0x00 Analog Compare Register TRIMPCtl 0x FFD1 0x00 TRIM Pulse Control FUSECtl 0x FFD2 0x00 FUSE Control VDDFCtl 0x FFD4 0x00 VDDFault Control SECReg 0x FFD7 0x00 Security Register MISCtl0 0x FFF1 0x00 Miscellaneous Control Register 0 MISCtl1 0x FFF2 0x10 Miscellaneous Control Register 1 LEDCtl 0x FFF3 0xFF LED Control Register Accumulator (ACC, A): ACC is the accumulator register. Most instructions use the accumulator to hold the operand. The mnemonics for accumulator-specific instructions refer to accumulator as "A", not ACC. B Register: The B register is used during multiply and divide instructions. It can also be used as a scratch-pad register to hold temporary data. 20 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Program Status Word (PSW): Table 9: PSW Register MSB LSB CV AC F0 RS1 RS OV Bit Symbol PSW.7 CV Carry flag. PSW.6 AC Auxiliary Carry flag for BCD operations. PSW.5 F0 General purpose Flag 0 available for user. PSW.4 RS1 P Function Register bank select control bits. The contents of RS1 and RS0 select the working register bank: RS1/RS0 PSW.3 - RS0 Bank Selected Location 00 Bank 0 (0x00 - 0x07) 01 Bank 1 (0x08 - 0x0F) 10 Bank 2 (0x10 - 0x17) 11 Bank 3 (0x18 - 0x1F) PSW.2 OV Overflow flag. PSW.1 F1 General purpose Flag 1 available for user. PSW.0 P Parity flag, affected by hardware to indicate odd / even number of "one" bits in the Accumulator, i.e. even parity. Stack Pointer: The stack pointer (SP) is a 1-byte register initialized to 0x07 after reset. This register is incremented before PUSH and CALL instructions, causing the stack to begin at location 0x08. Data Pointer: The data pointer (DPTR) is 2 bytes wide. The lower part is DPL, and the highest is DPH. It can be loaded as a 2-byte register (MOV DPTR,#data16) or as two registers (e.g. MOV DPL,#data8). It is generally used to access external code or data space (e.g. MOVC A,@A+DPTR or MOVX A,@DPTR respectively). Program Counter: The program counter (PC) is 2 bytes wide initialized to 0x0000 after reset. This register is incremented during the fetching operation code or when operating on data from program memory. Note: The program counter is not mapped to the SFR area. Port Registers: The I/O ports are controlled by Special Function Register USR70. The contents of the SFR can be observed on corresponding pins on the chip. Writing a 1 to any of the ports (see Table 10) causes the corresponding pin to be at high level (3.3V), and writing a 0 causes the corresponding pin to be held at low level (GND). The data direction register UDIR70 define individual pins as input or output pins (see the User (USR) Ports section for details). Table 10: Port Registers SFR Address R/W USR70 0x90 R/W Register for User port bit 7:0 read and write operations (pins USR0... USR7). UDIR70 0x91 R/W Data direction register for User port bits 0:7. Setting a bit to 0 means that the corresponding pin is an output. Register Rev. 1.4 Description 21 73S1210F Data Sheet DS_1210F_001 All ports on the chip are bi-directional. Each consists of a Latch (SFR `USR70'), an output driver, and an input buffer, therefore the MPU can output or read data through any of these ports if they are not used for alternate purposes. 1.6 Instruction Set All instructions of the generic 8051 microcontroller are supported. A complete list of the instruction set and of the associated op-codes is contained in the 73S12xxF Software User's Guide. 1.7 Peripheral Descriptions 1.7.1 Oscillator and Clock Generation The 73S1210F has one oscillator circuit for the main CPU clock. The main oscillator circuit is designed to operate with various crystal or external clock frequencies. An internal divider working in conjunction with a PLL and VCO provides a 96MHz internal clock within the 73S1210F. 96 MHz is the recommended frequency for proper operation of specific peripheral blocks such as the specific timers, ISO 7816 UART and interfaces, Step-up converter, and keypad. The clock generation and control circuits are shown in Figure 3. MCount(2:0) 12.00MHz M DIVIDER /(2*N + 4) DIVIDER /93760 HOSCen KEYCLK 1kHz MCLK 96MHz X12IN 12.00MHz HIGH XTAL OSC HCLK Phase Freq DET VCO X12OUT 1.5-48MHz ICLK 7.386MHz 7.386MHz MPU CLOCK - CPCLK 3.6923MHz div 2 div 2 CPUCKDiv CPU CLOCK DIVIDER 6 bits DIVIDE by 120 I2CCLK 400kHz I2C_2x 800kHz CLK1M DIVIDE by 96 SCLK CLOCK Prescaler 6bits div 2 div 2 SC/SCE CLOCK Prescaler 6bits 1MHz SEL SELSC SMART CARD LOGIC BLOCK CLOCK SCCLK ETU CLOCK DIVIDER 12 bits ETUCLK SCECLK See SC Clock descriptions for more accurate diagram SCCKenb Figure 3: Clock Generation and Control Circuits 22 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet The master clock control register enables different sections of the clock circuitry and specifies the value of the VCO Mcount divider. The MCLK must be configured to operate at 96MHz to ensure proper operation of some of the peripheral blocks according to the following formula: MCLK = (Mcount * 2 + 4) * FXTAL = 96MHz Mcount is configured in the MCLKCtl register must be bound between a value of 1 to 10. The possible crystal or external clock frequencies for getting MCLK = 96MHz are shown in Table 11. Table 11: Frequencies and Mcount Values for MCLK = 96MHz FXTAL (MHz) Mcount (N) 12.00 2 9.60 3 8.00 4 6.86 5 6.00 6 Master Clock Control Register (MCLKCtl): 0x8F 0x0A The MPU clock that drives the CPU core defaults to 3.6923MHz after reset. The MPU clock is scalable by configuring the MPU Clock Control register. Table 12: The MCLKCtl Register MSB LSB HSOEN KBEN SCEN - - MCT.2 Bit Symbol MCLKCtl.7 HSOEN MCLKCtl.6 KBEN 1 = Disable the keypad logic clock. MCLKCtl.5 SCEN 1 = Disable the smart card logic clock. MCLKCtl.4 - MCLKCtl.3 - MCLKCtl.2 MCT.2 MCLKCtl.1 MCT.1 MCLKCtl.0 MCT.0 Rev. 1.4 MCT.1 MCT.0 Function High-speed oscillator disable. When set = 1, disables the high-speed crystal oscillator and VCO/PLL system. Do not set this bit = 1. This value determines the ratio of the VCO frequency (MCLK) to the high-speed crystal oscillator frequency such that: MCLK = (MCount*2 + 4)* FXTAL. The default value is MCount = 2h such that MCLK = (2*2 + 4)*12.00MHz = 96MHz. 23 73S1210F Data Sheet DS_1210F_001 MPU Clock Control Register (MPUCKCtl): 0xFFA1 0x0C Table 13: The TCON Register MSB LSB - - Bit MPUCKCtl.7 Symbol - MPUCKCtl.6 - MPUCKCtl.5 MDIV.5 MPUCKCtl.4 MDIV.4 MPUCKCtl.3 MDIV.3 MPUCKCtl.2 MDIV.2 MPUCKCtl.1 MDIV.1 MPUCKCtl.0 MDIV.0 MDIV.5 MDIV.4 MDIV.3 MDIV.2 MDIV.1 MDIV.0 Function This value determines the ratio of the MPU master clock frequency to the VCO frequency (MCLK) such that MPUClk = MCLK/(2 * (MPUCKDiv(5:0) + 1)). Do not use values of 0 or 1 for MPUCKDiv(n). Default is 0Ch to set CPCLK = 3.6923MHz. X12IN 73S1210F X12OUT The oscillator circuits are designed to connect directly to standard parallel resonant crystal in a Pierce oscillator configuration. Each side of the crystal should include a 22pF capacitor to ground for both oscillator circuits and a 1M resistor is required across the 12MHz crystal. 1M 12MHz 22pF 22pF Note: The crystal should be placed as close as possible to the IC, and vias should be avoided. Figure 4: Oscillator Circuit 24 Rev. 1.4 DS_1210F_001 1.7.2 73S1210F Data Sheet Power Supply Management The detailed power supply management logic block diagram is shown in Figure 5. VBUS + VBUSTH NO VPC NC S R SET CLR Q Q DC-DC Converter EN / Pass Through* PTEN VBAT VP LIN *Pass Through -> VP = VPC D ON_OFF SET Q Debounce Circuit CLR OFF_REQ Q INT INT3 Delay Circuit (POR) MPU PWRDN* VP *PWRDN bit in MISCtl0 Pass Through Mode Enable VCC Voltage Select VCC Regulator VCC Enable Power Control VDD Regulator VDD to Internal Circuits VCC Smart Card Power To optional VDD external circuits 20mA max. Figure 5: Detailed Power Management Logic Block Diagram The 73S1210F contains a power supply and converter circuit that takes power from any one of three sources; VPC, VBUS, or VBAT. VPC is specified to range from 2.7 to 6.5 volts. It can typically be supplied by a single cell battery with a voltage range of 2.7 to approximately 3.1 volts or by a standard supply of 3.3 or 5 volts. VBUS is typically supplied by an external power supply and ranges in value from 4.4 to 5.5 volts (6.5V maximum). Rev. 1.4 25 73S1210F Data Sheet DS_1210F_001 VBAT is expected to be supplied from a battery of three to four series connected cells with a voltage value of 4.0 to 6.5 volts. VBAT and VBUS are internally switched to VPC by two separate FET switches configured as a SPDT switch (break-before-make). They will not be enabled at the same time. VBUS is automatically selected in lieu of VBAT when VBUS is present (i.e. VBUS always has the priority). If VPC is provided and either VBAT or VBUS is also used, the source of VPC must be diode isolated from the VPC pin to prevent current flow from VBAT or VBUS into the VPC source. The power that is supplied to the VPC pin (externally or internally, i.e. through VBAT or VBUS - see above) is up-converted to the intermediate voltage VP utilizing an inductive, step-up converter. A series power inductor (nominal value = 10 H) must be connected from VPC to the pin LIN, and a 10F low ESR filter capacitor must be connected to VPC. VP requires a 4.7F filter capacitor and will have a nominal value of 5.5 volts during normal operation. VP is used internally by the smart card electrical interface circuit and is regulated to the desired smart card supply VCC voltage (can be programmed for values of 5V, 3V, or 1.8V). VP is also used internally to generate a 3.3V nominal, regulated power supply VDD. VDD is output on pin 68 and must be directly tied to all other VDD pins on the 73S1210F (pins 28 and 40). VDD powers all the digital logic, input/output buffering, and analog functions. It can also be used for external circuitry: up to 20mA current can be supplied to external devices simultaneously to the 73S1210F's digital core maximum consumption. 1.7.3 Power ON/OFF The 73S1210F features an ON_OFF input pin for a momentary contact, main-system ON/OFF switch. The purpose of this switch is to place the circuit in a very low-power mode - the "OFF" mode - where all circuits are no longer powered, therefore allowing the lowest possible current consumption. When in "OFF" mode, an action on the ON/OFF switch will turn-on the power supply of the digital core (VDD) and apply a power-on-reset condition. Alternatively, entering the "OFF" mode from the "ON" mode requires firmware action. When in "ON" mode, an action on the ON/OFF switch will send a request to the controller that will have to be acknowledged (firmware action required) in order to enter the "OFF" state. When placed into the "OFF" state, the 73S1210F will consume minimum current from VPC and VBAT; VP and VDD will be unavailable (VDD out = 0V and VP = 0V). When in "ON" mode, the 73S1210F will operate normally, with all the features described in this document available. VP and VDD will be available (VDD out = 3.3V and VP = 5.5V nominal). Whenever VBUS power is supplied, the circuit will be automatically in the "ON" state. The functions of the ON/OFF switch and circuitry are overridden and the 73S1210F is in the "ON" state with VP and VDD available. Without VBUS applied, the circuit is by default in the "OFF" state, and will respond only to the ON_OFF pin. The ON_OFF pin should be connected to an SPST switch to ground. If the circuit is OFF and the switch is closed for a debounce period of 50-100ms, the circuit will go into the "ON" state wherein all functions are operating in normal fashion. If the circuit is in the "ON" state and the ON/OFF pin is connected to ground for a period greater than the debounce period, OFF_REQ will be asserted high and held regardless of the state of ON/OFF. The OFF_REQ signal should be connected to one of the interrupt pins to signal the CPU core that a request to shutdown has been initiated. The firmware will acknowledge this request by setting the SCPWRDN bit in the Smart Card VCC Control/Status Register (VccCtl) high after it has completed all shutdown activities. When SCPWRDN is set high, the circuit will deactivate the smart card interface if required and turn off all analog functions and the VDD supply for the logic and companion circuits. The default state upon application of power is the "OFF" state unless power is supplied to the VBUS supply. Note that at any time, the firmware may assert SCPWRDN and the 26 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 73S1210F will go into the "OFF" state (when VBUS is not present). If the ON/OFF switch function is not desired and the application does not need to shut down power on VDD, the ON_OFF input can be permanently grounded which will automatically turn on VDD when power is supplied on any of the VPC, VBAT or VBUS power supply inputs. If power is applied to both VBAT and VBUS, the circuit will automatically consume power from only the VBUS source. The 73S1210F will be unconditionally "ON" when VBUS is applied. If the VBUS source is removed, the 73S1210F will switchover to the VBAT input supply and remain in the "ON" state. The firmware should assert SCPWRDN based on no activity or VBUS removal to reduce battery power consumption. When operating from VBUS, and not calling for VCC, the step-up converter becomes a simple switch connecting VBUS to VP in order to save power. Note: When the ON_OFF switch function is not needed, i.e. when the 73S1210F must be in an always-ON state when using another supply than VBUS (VPC or VBAT), some external discrete components are needed. 1.7.4 Power Control Modes The 73S1210F contains circuitry to disable portions of the device and place it into a lower power standby mode or power down the 73S1210F into its "OFF" mode. The standby mode will stop the core, clock subsystem and the peripherals connected to it. This is accomplished by either shutting off the power or disabling the clock going to the block. The Miscellaneous Control registers MISCtl0, MISCtl1 and the Master Clock Control register (MCLKCtl) provide control over the power modes. The PWRDN bit in MISCtl0 will setup the 73S1210F for standby or "OFF" modes. Depending on the state of the ON/OFF circuitry and power applied to the VBUS input, the 73S1210F will go into either standby mode or power "OFF" mode. If system power is provided by, VBUS or the ON/OFF circuitry is in the "ON" state, the MPU core will placed into standby mode. If the VBUS input is not sourcing power and the ON/OFF circuitry is in the "OFF" state, setting the PWRDN bit will shut down the converter and VP will turn off. The power down mode should only be initiated by setting the PWRDN bit in the MISCtl0 register and not by manipulating individual control bits in various registers. Figure 6 shows how the PWRDN bit controls the various functions that comprise power down state. Note: the PWRDN Signal is not the direct version of the PWRDN Bit. There are delays from assertion of the PWRDN bit to the assertion of the PWRDN Signal (32 MPU clocks). Refer to the Power Down sequence diagram. MISCtl0 - PWRDN PWRDN Signal Analog functions (VCO, PLL, reference and bias circuits, etc.) VDDFCtl - VDDFEN + VDDFAULT ACOMP - CMPEN + ANALOG COMPARE MCLCKCtl - HOSEN + High Speed OSC SCVCCCtl - SCPRDN + Smart Card Power MISCtl1 - FRPEN + These are the registers and the names of the control bits. Flash Read Pulse one-shot circuit These are the block references. Figure 6: Power Down Control Rev. 1.4 27 73S1210F Data Sheet DS_1210F_001 When the PWRDN bit is set, the clock subsystem will provide a delay of 32 MPUCLK cycles to allow the program to set the STOP bit in the PCON register. This delay will enable the program to properly halt the core before the analog circuits shut down (high speed oscillator, VCO/PLL, voltage reference and bias circuitry, etc.). The PDMUX bit in SFR INT5Ctl should be set prior to setting the PWRDN bit in order to configure the wake up interrupt logic. The power down mode is de-asserted by any of the interrupts connected to external interrupts 0, 4 and 5 (external USR[0:7], smart card and Keypad). These interrupt sources are OR'ed together and routed through some delay logic into INT0 to provide this functionality. The interrupt will turn on the power to all sections that were shut off and start the clock subsystem. After the clock subsystem clocks start running, the MPUCLK begins to clock a 512 count delay counter. When the counter times out, the interrupt will then be active on INT0 and the program can resume. Figure 7 shows the detailed logic for waking up the 73S1210F from a power down state using these specific interrupt sources. Figure 8 shows the timing associated with the power down mode. PDMUX (FF94h:bit7) USR0 USR1 USR2 USR3 USR4 USR5 USR6 USR7 USR[7:0] Control MPU 0 USRxINTSrc set to 4(ext INT0 high) or 6(ext INT0 low) INT0 1 INT4 CE INT5 TC 9 BIT CNTR CLR RESETB D Q PWRDN (FFF1h:bit7) PWRDN_analog CLR TC CE RESETB 5 BIT CNTR Notes: 1. The counters are clocked by the MPUCLK 2. TC - Terminal count (high at overflow) 3. CE - Count enable CLR RESETB Figure 7: Detail of Power Down Interrupt Logic 28 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet text t0 PWRDN BIT t1 PWRDN SIG t4 EXT. EVENT t6 INT0 to MPU t7 MPU STOP ANALOG Enable t2 t3 t5 PLL CLOCKS t0: MPU sets PWRDN bit. t1: 32 MPU clock cycles after t0, the PWRDN SIG is asserted, turning all analog functions OFF. t2: MPU executes STOP instruction, must be done prior to t1. t3: Analog functions go to OFF condition. No Vref, PLL/VCO, Ibias, etc. text: An external event (RTC, Keypad, Card event, USB) occurs. t4: PWRDN bit and PWRDN signal are cleared by external event. t5: High-speed oscillator/PLL/VCO operating. t6: After 512 MPU clock cycles, INT0 to MPU is asserted. t7: INT0 causes MPU to exit STOP condition. Figure 8: Power Down Sequencing Rev. 1.4 29 73S1210F Data Sheet DS_1210F_001 External Interrupt Control Register (INT5Ctl): 0xFF94 0x00 Table 14: The INT5Ctl Register MSB LSB PDMUX Bit - - - - - KPIEN KPINT Symbol Function INT5Ctl.7 PDMUX When set = 1, enables interrupts from Keypad (normally going to int5), Smart Card interrupts (normally going to int4), or USR(7:0) pins (int0) to cause interrupt on int0. The assertion of the interrupt to int0 is delayed by 512 MPU clocks to allow the analog circuits, including the clock system, to stabilize. This bit must be set prior to asserting the PWRDN bit in order to properly configure the interrupts that will wake up the circuit. This bit is reset = 0 when this register is read. INT5Ctl.6 - INT5Ctl.5 - INT5Ctl.4 - INT5Ctl.3 - INT5Ctl.2 - INT5Ctl.1 KPIEN Keypad interrupt enable. INT5Ctl.0 KPINT Keypad interrupt flag. Miscellaneous Control Register 0 (MISCtl0): 0xFFF1 0x00 Table 15: The MISCtl0 Register MSB LSB PWRDN Bit - - - Symbol MISCtl0.7 PWRDN MISCtl0.6 - MISCtl0.5 - MISCtl0.4 - MISCtl0.3 - MISCtl0.2 - MISCtl0.1 SLPBK MISCtl0.0 SSEL 30 - - SLPBK SSEL Function This bit sets the circuit into a low-power condition. All analog (high-speed oscillator and VCO/PLL) functions are disabled 32 MPU clock cycles after this bit is set = 1. This allows time for the next instruction to set the STOP bit in the PCON register to stop the CPU core. The MPU is not operative in this mode. When set, this bit overrides the individual control bits that otherwise control power consumption. UART loop back testing mode. Serial port pins select. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Miscellaneous Control Register 1 (MISCtl1): 0xFFF2 0x10 Table 16: The MISCtl1 Register MSB LSB - - Bit Symbol MISCtl1.7 - MISCtl1.6 - FRPEN FLSH66 - - - - Function MISCtl1.5 FRPEN Flash Read Pulse enable (low). If FRPEN = 1, the Flash Read signal is passed through with no change. When FRPEN = 0 a one-shot circuit that shortens the Flash Read signal is enabled to save power. The Flash Read pulse will shorten to 40 or 66ns (approximate based on the setting of the FLSH66 bit) in duration, regardless of the MPU clock rate. For MPU clock frequencies greater than 10MHz, this bit should be set high. MISCtl1.4 FLSH66 When high, creates a 66ns Flash read pulse, otherwise creates a 40ns read pulse when FRPEN is set. MISCtl1.3 - MISCtl1.2 - MISCtl1.1 - MISCtl1.0 - Master Clock Control Register (MCLKCtl): 0x8F 0x0A Table 17: The MCLKCtl Register MSB LSB HSOEN KBEN SCEN - - MCT.2 MCT.1 MCT.0 Bit Symbol Function MCLKCtl.7 HSOEN* MCLKCtl.6 KBEN 1 = Disable the keypad logic clock. This bit is not changed in PWRDN mode but the function is disabled. MCLKCtl.5 SCEN 1 = Disable the smart card logic clock. This bit is not changed in PWRDN mode but the function is disabled. Interrupt logic for card insertion/removal remains operable even with smart card clock disabled. MCLKCtl.4 - MCLKCtl.3 - MCLKCtl.2 MCT.2 MCLKCtl.1 MCT.1 MCLKCtl.0 MCT.0 High-speed oscillator enable. When set = 1, disables the high-speed crystal oscillator and VCO/PLL system. This bit is not changed when the PWRDN bit is set but the oscillator/VCO/PLL is disabled. This value determines the ratio of the VCO frequency (MCLK) to the high-speed crystal oscillator frequency such that: MCLK = (MCount*2 + 4)*Fxtal. The default value is MCount = 2h such that MCLK = (2*2 + 4)*12.00MHz = 96MHz. *Note: The HSOEN bit should never be set under normal circumstances. Power down control should only be initiated via use of the PWRDN bit in MISCtl0. Rev. 1.4 31 73S1210F Data Sheet DS_1210F_001 Power Control Register 0 (PCON): 0x87 0x00 The SMOD bit used for the baud rate generator is set up via this register. Table 18: The PCON Register MSB LSB SMOD 32 - - - Bit Symbol PCON.7 SMOD PCON.6 - PCON.5 - PCON.4 - PCON.3 GF1 General purpose flag 1. PCON.2 GF0 General purpose flag 1. PCON.1 STOP Sets CPU to Stop mode. PCON.0 IDLE Sets CPU to Idle mode. GF1 GF0 STOP IDLE Function If SM0D = 1, the baud rate is doubled. Rev. 1.4 DS_1210F_001 1.7.5 73S1210F Data Sheet Interrupts The 80515 core provides 10 interrupt sources with four priority levels. Each source has its own request flag(s) located in a special function register (TCON, IRCON, and SCON). Each interrupt requested by the corresponding flag can be individually enabled or disabled by the enable bits in SFRs IEN0, IEN1, and IEN2. Some of the 10 sources are multiplexed in order to expand the number of interrupt sources. These are described in more detail in the respective sections. External interrupts are the interrupts external to the 80515 core, i.e. signals that originate in other parts of the 73S1210F, for example the USR I/O, smart card interface, analog comparators, etc. The external interrupt configuration is shown in Figure 9. PDMUXCtl Clear PWRDN bit USR0 USR1 t0 USR2 USR3 USR Pads USR4 USR5 USR USR USR Int USR Int Int Ctl Int Ctl Ctl Ctl 0 int0 1 t1 int1 USR6 USR7 + INT2 int3 CRDCtl + VCC_OK int2 INT Pads INT3 Card_Det Delay VccCTL Wait Timeout Card Event VCC_TMR RxData TX_Event Tx_Sent TX_Error RX_Error + SCInt INT5 Ctl KeyPad SCIE int4 MPU CORE During STOP, IDLE when PWRDN bit is set int5 I2C VDD_Fault Analog Comp INT6 Ctl int6 Serial Ch 0 SerChan 0 int Serial Ch 1 SerChan 1 int Figure 9: External Interrupt Configuration Rev. 1.4 33 73S1210F Data Sheet 1.7.5.1 DS_1210F_001 Interrupt Overview When an interrupt occurs, the MPU will vector to the predetermined address as shown in Table 32. Once the interrupt service has begun, it can only be interrupted by a higher priority interrupt. The interrupt service is terminated by a return from the RETI instruction. When a RETI is performed, the processor will return to the instruction that would have been next when the interrupt occurred. When the interrupt condition occurs, the processor will also indicate this by setting a flag bit. This bit is set regardless of whether the interrupt is enabled or disabled. Each interrupt flag is sampled once per machine cycle, then samples are polled by the hardware. If the sample indicates a pending interrupt when the interrupt is enabled, then the interrupt request flag is set. On the next instruction cycle, the interrupt will be acknowledged by hardware forcing an LCALL to the appropriate vector address. Interrupt response will require a varying amount of time depending on the state of the MPU when the interrupt occurs. If the MPU is performing an interrupt service with equal or greater priority, the new interrupt will not be invoked. In other cases, the response time depends on the current instruction. The fastest possible response to an interrupt is 7 machine cycles. This includes one machine cycle for detecting the interrupt and six cycles to perform the LCALL. 1.7.5.2 Special Function Registers for Interrupts Interrupt Enable 0 Register (IEN0): 0xA8 0x00 Table 19: The IEN0 Register MSB EAL 34 LSB WDT - ES0 ET1 EX1 Bit Symbol IEN0.7 EAL EAL = 0 - disable all interrupts. IEN0.6 WDT Not used for interrupt control. IEN0.5 - IEN0.4 ES0 ES0 = 0 - disable serial channel 0 interrupt. IEN0.3 ET1 ET1 = 0 - disable timer 1 overflow interrupt. IEN0.2 EX1 EX1 = 0 - disable external interrupt 1. IEN0.1 ET0 ET0 = 0 - disable timer 0 overflow interrupt. IEN0.0 EX0 EX0 = 0 - disable external interrupt 0. ET0 EX0 Function Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Interrupt Enable 1 Register (IEN1): 0xB8 0x00 Table 20: The IEN1 Register MSB - LSB SWDT EX6 EX5 EX4 EX3 Bit Symbol IEN1.7 - IEN1.6 SWDT IEN1.5 EX6 EX6 = 0 - disable external interrupt 6. IEN1.4 EX5 EX5 = 0 - disable external interrupt 5. IEN1.3 EX4 EX4 = 0 - disable external interrupt 4. IEN1.2 EX3 EX3 = 0 - disable external interrupt 3. IEN1.1 EX2 EX2 = 0 - disable external interrupt 2. IEN1.0 - EX2 - Function Not used for interrupt control. Interrupt Enable 2 Register (IEN2): 0x9A 0x00 Table 21: The IEN2 Register MSB - Bit Symbol IEN2.0 ES1 Rev. 1.4 LSB - - - - - - ES1 Function ES1 = 0 - disable serial channel interrupt. 35 73S1210F Data Sheet DS_1210F_001 Timer/Counter Control Register (TCON): 0x88 0x00 Table 22: The TCON Register MSB LSB TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0 Bit Symbol Function TCON.7 TF1 Timer 1 overflow flag. TCON.6 TR1 Not used for interrupt control. TCON.5 TF0 Timer 0 overflow flag. TCON.4 TR0 Not used for interrupt control. TCON.3 IE1 Interrupt 1 edge flag is set by hardware when the falling edge on external interrupt int1 is observed. Cleared when an interrupt is processed. TCON.2 IT1 Interrupt 1 type control bit. 1 selects falling edge and 0 selects low level for input pin to cause an interrupt. TCON.1 IE0 Interrupt 0 edge flag is set by hardware when the falling edge on external interrupt int0 is observed. Cleared when an interrupt is processed. TCON.0 IT0 Interrupt 0 type control bit. 1 selects falling edge and 0 sets low level for input pin to cause interrupt. Timer/Interrupt 2 Control Register (T2CON): 0xC8 0x00 Table 23: The T2CON Register MSB LSB - I3FR Bit Symbol T2CON.7 - I2FR - - - - - Function External interrupt 3 failing/rising edge flag. T2CON.6 I3FR T2CON.5 I2FR T2CON.4 - T2CON.3 - T2CON.2 - T2CON.1 - T2CON.0 - I3FR = 0 external interrupt 3 negative transition active. I3FR = 1 external interrupt 3 positive transition active. External interrupt 3 failing/rising edge flag. 36 I2FR = 0 external interrupt 3 negative transition active. I2FR = 1 external interrupt 3 positive transition active. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Interrupt Request Register (IRCON): 0xC0 0x00 Table 24: The IRCON Register MSB LSB - - EX6 IEX5 Bit Symbol IRCON.7 - IRCON.6 - IRCON.5 IEX6 External interrupt 6 flag. IRCON.4 IEX5 External interrupt 5 flag. IRCON.3 IEX4 External interrupt 4 flag. IRCON.2 IEX3 External interrupt 3 flag. IRCON.1 IEX2 External interrupt 2 flag. IRCON.0 - 1.7.5.3 IEX4 IEX3 IEX2 - Function External Interrupts The external interrupts (external to the CPU core) are connected as shown in Table 25. Interrupts with multiple sources are OR'ed together and individual interrupt source control is provided in XRAM SFRs to mask the individual interrupt sources and provide the corresponding interrupt flags. Multifunction USR [7:0] pins control Interrupts 0 and 1. Dedicated external interrupt pins INT2 and INT3 control interrupts 2 and 3. The polarity of interrupts 2 and 3 is programmable in the MPU. Interrupts 4, 5 and 6 have multiple peripheral sources and are multiplexed to one of these three interrupts. The peripheral functions will be described in subsequent sections. Generic 80515 MPU literature states that interrupts 4 through 6 are defined as rising edge sensitive. Thus, the hardware signals attached to interrupts 4, 5 and 6 are converted to rising edge level by the hardware. SFR (special function register) enable bits must be set to permit any of these interrupts to occur. Likewise, each interrupt has its own flag bit that is set by the interrupt hardware and is reset automatically by the MPU interrupt handler. Table 25: External MPU Interrupts External Interrupt Connection Polarity Flag Reset 0 USR I/O High Priority see USRIntCtlx Automatic 1 USR I/O Low Priority see USRIntCtlx Automatic 2 External Interrupt Pin INT2 Edge selectable Automatic 3 External Interrupt Pin INT3 Edge selectable Automatic 4 Smart Card Interrupts N/A Automatic 5 Keypad N/A Automatic N/A Automatic 6 2 I C, VDD_Fault, Analog Comp Note: Interrupts 4, 5 and 6 have multiple interrupt sources and the flag bits are cleared upon reading of the corresponding register. To prevent any interrupts from being ignored, the register containing multiple interrupt flags should be stored temporary to allow each interrupt flag to be tested separately to see which interrupt(s) is/are pending. Rev. 1.4 37 73S1210F Data Sheet DS_1210F_001 Table 26: Control Bits for External Interrupts Enable Bit 1.7.5.4 Description Flag Bit Description EX0 Enable external interrupt 0 IE0 External interrupt 0 flag EX1 Enable external interrupt 1 IE1 External interrupt 1 flag EX2 Enable external interrupt 2 IEX2 External interrupt 2 flag EX3 Enable external interrupt 3 IEX3 External interrupt 3 flag EX4 Enable external interrupt 4 IEX4 External interrupt 4 flag EX5 Enable external interrupt 5 IEX5 External interrupt 5 flag EX6 Enable external interrupt 6 IEX6 External interrupt 6 flag Power Down Interrupt Logic The 73S1210F contains special interrupt logic to allow INT0 to wake up the CPU from a power down (CPU STOP) state. See the Power Control Modes section for details. 1.7.5.5 Interrupt Priority Level Structure All interrupt sources are combined in groups, as shown in Table 27. Table 27: Priority Level Groups Group 0 External interrupt 0 Serial channel 1 interrupt 1 Timer 0 interrupt - External interrupt 2 2 External interrupt 1 - External interrupt 3 3 Timer 1 interrupt - External interrupt 4 4 Serial channel 0 interrupt - External interrupt 5 5 - - External interrupt 6 Each group of interrupt sources can be programmed individually to one of four priority levels by setting or clearing one bit in the special function register IP0 and one in IP1. If requests of the same priority level are received simultaneously, an internal polling sequence as per Table 31 determines which request is serviced first. IEN enable bits must be set to permit any of these interrupts to occur. Likewise, each interrupt has its own flag bit that is set by the interrupt hardware and is reset automatically by the MPU interrupt handler. Interrupt Priority 0 Register (IP0): 0xA9 0x00 Table 28: The IP0 Register MSB - LSB WDTS IP0.5 IP0.4 IP0.3 IP0.2 IP0.1 IP0.0 Note: WDTS is not used for interrupt controls. 38 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Interrupt Priority 1 Register (IP1): 0xB9 0x00 Table 29: The IP1 Register MSB - LSB - IP1.5 IP1.4 IP1.3 IP1.2 IP1.1 IP1.0 Table 30: Priority Levels IP1.x IP0.x Priority Level 0 0 Level0 (lowest) 0 1 Level1 1 0 Level2 1 1 Level3 (highest) Table 31: Interrupt Polling Sequence External interrupt 0 Serial channel 1 interrupt Polling sequence Timer 0 interrupt External interrupt 2 External interrupt 1 External interrupt 3 Timer 1 interrupt Serial channel 0 interrupt External interrupt 4 External interrupt 5 External interrupt 6 1.7.5.6 Interrupt Sources and Vectors Table 32 shows the interrupts with their associated flags and vector addresses. Table 32: Interrupt Vectors Interrupt Request Flag Description Rev. 1.4 Interrupt Vector Address N/A Chip Reset 0x0000 IE0 External interrupt 0 0x0003 TF0 Timer 0 interrupt 0x000B IE1 External interrupt 1 0x0013 TF1 Timer 1 interrupt 0x001B RI0/TI0 Serial channel 0 interrupt 0x0023 RI1/TI1 Serial channel 1 interrupt 0x0083 IEX2 External interrupt 2 0x004B IEX3 External interrupt 3 0x0053 IEX4 External interrupt 4 0x005B IEX5 External interrupt 5 0x0063 IEX6 External interrupt 6 0x006B 39 73S1210F Data Sheet 1.7.6 DS_1210F_001 UART The 80515 core of the 73S1210F includes two separate UARTs that can be programmed to communicate with a host. The 73S1210F can only connect one UART at a time since there is only one set of TX and Rx pins. The MISCtl0 register is used to select which UART is connected to the TX and RX pins. Each UART has a different set of operating modes that the user can select according to their needs. The UART is a dedicated 2-wire serial interface, which can communicate with an external host processor at up to 115,200 bits/s. The TX and RX pins operate at the VDD supply voltage levels and should never exceed 3.6V. The operation of each pin is as follows: RX: Serial input data is applied at this pin. Conforming to RS-232 standard, the bytes are input LSB first. The voltage applied at RX must not exceed 3.6V. TX: This pin is used to output the serial data. The bytes are output LSB first. The 73S1210F has several UART-related read/write registers. All UART transfers are programmable for parity enable, parity select, 2 stop bits/1 stop bit and XON/XOFF options for variable communication baud rates from 300 to 115200 bps. Table 33 shows the selectable UART operation modes and Table 34 shows how the baud rates are calculated. Table 33: UART Modes UART 0 UART 1 Mode 0 N/A Start bit, 8 data bits, parity, stop bit, variable baud rate (internal baud rate generator). Mode 1 Start bit, 8 data bits, stop bit, variable baud rate (internal baud rate generator or timer 1). Start bit, 8 data bits, stop bit, variable baud rate (internal baud rate generator). Mode 2 Start bit, 8 data bits, parity, stop bit, fixed baud rate 1/32 or 1/64 of fCKMPU. N/A Mode 3 Start bit, 8 data bits, parity, stop bit, variable baud rate (internal baud rate generator or timer 1). N/A Note: Parity of serial data is available through the P flag of the accumulator. Seven-bit serial modes with parity, such as those used by the FLAG protocol, can be simulated by setting and reading bit 7 of 8-bit output data. Seven-bit serial modes without parity can be simulated by setting bit 7 to a constant 1. 8-bit serial modes with parity can be simulated by setting and reading the 9th bit, using the control bits S0CON3 and S1CON3 in the S0COn and S1CON SFRs. Table 34: Baud Rate Generation Using Timer 1 Serial Interface 0 Serial Interface 1 2 smod * fCKMPU/ (384 * (256-TH1)) N/A Using Internal Baud Rate Generator 2smod * fCKMPU/(64 * (210-S0REL)) fCKMPU/(32 * (210-S1REL)) Note: S0REL (9:0) and S1REL (9:0) are 10-bit values derived by combining bits from the respective timer reload registers SxRELH (bits 1:0) and SxRELL (bits 7:0). TH1 is the high byte of timer 1. The SMOD bit is located in the PCON SFR. 40 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Power Control Register 0 (PCON): 0x87 0x00 The SMOD bit used for the baud rate generator is set up via this register. Table 35: The PCON Register MSB LSB SMOD - - - GF1 Bit Symbol PCON.7 SMOD PCON.6 - PCON.5 - PCON.4 - PCON.3 GF1 General purpose flag 1. PCON.2 GF0 General purpose flag 1. PCON.1 STOP Sets CPU to Stop mode. PCON.0 IDLE Sets CPU to Idle mode. GF0 STOP IDLE Function If SM0D = 1, the baud rate is doubled. Baud Rate Control Register 0 (BRCON): 0xD8 0x00 The BSEL bit used to enable the baud rate generator is set up via this register. Table 36: The BRCON Register MSB LSB BSEL - Bit Symbol BRCON.7 BSEL BRCON.6 - BRCON.5 - BRCON.4 - BRCON.3 - BRCON.2 - BRCON.1 - BRCON.0 - Rev. 1.4 - - - - - - Function If BSEL = 0, the baud rate is derived using timer 1. If BSEL = 1 the baud rate generator circuit is used. . 41 73S1210F Data Sheet DS_1210F_001 Miscellaneous Control Register 0 (MISCtl0): 0xFFF1 0x00 Transmit and receive (TX and RX) pin selection and loop back test configuration are setup via this register. Table 37: The MISCtl0 Register MSB LSB PWRDN - Bit Symbol MISCtl0.7 PWRDN MISCtl0.6 - MISCtl0.5 - MISCtl0.4 - MISCtl0.3 - MISCtl0.2 - MISCtl0.1 SLPBK MISCtl0.0 SSEL 1.7.6.1 - - - - SLPBK SSEL Function This bit places the 73S1210F into a power down state. 1 = UART loop back testing mode. The pins TXD and RXD are to be connected together externally (with SLPBK =1) and therefore: SLPBK SSEL Mode 0 0 normal using Serial_0 0 1 normal using Serial_1 1 0 Serial_0 TX feeds Serial_1 RX 1 1 Serial_1 TX feeds Serial_0 RX Selects either Serial_1 if set =1 or Serial_0 if set = 0 to be connected to RXD and TXD pins. Serial Interface 0 The Serial Interface 0 can operate in 4 modes: * Mode 0 Pin RX serves as input and output. TX outputs the shift clock. 8 bits are transmitted with LSB first. The baud rate is fixed at 1/12 of the crystal frequency. Reception is initialized in Mode 0 by setting the flags in S0CON as follows: RI0 = 0 and REN0 = 1. In other modes, a start bit when REN0 = 1 starts receiving serial data. * Mode 1 Pin RX serves as input, and TX serves as serial output. No external shift clock is used, 10 bits are transmitted: a start bit (always 0), 8 data bits (LSB first), and a stop bit (always 1). On receive, a start bit synchronizes the transmission, 8 data bits are available by reading S0BUF, and stop bit sets the flag RB80 in the Special Function Register S0CON. In mode 1 either internal baud rate generator or timer 1 can be use to specify baud rate. * Mode 2 This mode is similar to Mode 1, with two differences. The baud rate is fixed at 1/32 or 1/64 of oscillator frequency and 11 bits are transmitted or received: a start bit (0), 8 data bits (LSB first), a programmable 9th bit, and a stop bit (1). The 9th bit can be used to control the parity of the serial interface: at transmission, bit TB80 in S0CON is output as the 9th bit, and at receive, the 9th bit affects RB80 in Special Function Register S0CON. 42 Rev. 1.4 DS_1210F_001 * 73S1210F Data Sheet Mode 3 The only difference between Mode 2 and Mode 3 is that in Mode 3 either internal baud rate generator or timer 1 can be use to specify baud rate. The S0BUF register is used to read/write data to/from the serial 0 interface. Serial Interface 0 Control Register (S0CON): 0x9B 0x00 Transmit and receive data are transferred via this register. Table 38: The S0CON Register MSB LSB SM0 SM1 Bit Symbol S0CON.7 SM0 S0CON.6 SM1 SM20 REN0 TB80 RB80 TI0 RI0 Function These two bits set the UART0 mode: Mode Description SM0 SM1 0 N/A 0 0 1 8-bit UART 0 1 2 9-bit UART 1 0 3 9-bit UART 1 1 S0CON.5 SM20 Enables the inter-processor communication feature. S0CON.4 REN0 If set, enables serial reception. Cleared by software to disable reception. S0CON.3 TB80 The 9th transmitted data bit in Modes 2 and 3. Set or cleared by the MPU, depending on the function it performs (parity check, multiprocessor communication etc.). S0CON.2 RB80 In Modes 2 and 3 it is the 9th data bit received. In Mode 1, if SM20 is 0, RB80 is the stop bit. In Mode 0 this bit is not used. Must be cleared by software. S0CON.1 TI0 Transmit interrupt flag, set by hardware after completion of a serial transfer. Must be cleared by software. S0CON.0 RI0 Receive interrupt flag, set by hardware after completion of a serial reception. Must be cleared by software. Rev. 1.4 43 73S1210F Data Sheet 1.7.6.2 DS_1210F_001 Serial Interface 1 The Serial Interface 1 can operate in 2 modes: * Mode A This mode is similar to Mode 2 and 3 of Serial interface 0, 11 bits are transmitted or received: a start bit (0), 8 data bits (LSB first), a programmable 9th bit, and a stop bit (1). The 9th bit can be used to control the parity of the serial interface: at transmission, bit TB81 in S1CON is outputted as the 9th bit, and at receive, the 9th bit affects RB81 in Special Function Register S1CON. The only difference between Mode 3 and A is that in Mode A only the internal baud rate generator can be use to specify baud rate. * Mode B This mode is similar to Mode 1 of Serial interface 0. Pin RX serves as input, and TX serves as serial output. No external shift clock is used, 10 bits are transmitted: a start bit (always 0), 8 data bits (LSB first), and a stop bit (always 1). On receive, a start bit synchronizes the transmission, 8 data bits are available by reading S1BUF, and stop bit sets the flag RB81 in the Special Function Register S1CON. In mode 1, the internal baud rate generator is use to specify the baud rate. The S1BUF register is used to read/write data to/from the serial 1 interface. Serial Interface Control Register (S1CON): 0x9B 0x00 The function of the serial port depends on the setting of the Serial Port Control Register S1CON. Table 39: The S1CON Register MSB LSB SM - Bit Symbol S1CON.7 SM SM21 REN1 TB81 RB81 TI1 RI1 Function Sets the UART operation mode. SM Mode Description Baud Rate 0 A 9-bit UART variable 1 B 8-bit UART variable S1CON.6 - S1CON.5 SM21 Enables the inter-processor communication feature. S1CON.4 REN1 If set, enables serial reception. Cleared by software to disable reception. S1CON.3 TB81 The 9th transmitted data bit in Mode A. Set or cleared by the MPU, depending on the function it performs (parity check, multiprocessor communication, etc.). S1CON.2 RB81 In Mode B, if sm21 is 0, rb81 is the stop bit. Must be cleared by software. S1CON.1 TI1 Transmit interrupt flag, set by hardware after completion of a serial transfer. Must be cleared by software. S1CON.0 RI1 Receive interrupt flag, set by hardware after completion of a serial reception. Must be cleared by software. Multiprocessor operation mode: The feature of receiving 9 bits in Modes 2 and 3 of Serial Interface 0 or in Mode A of Serial Interface 1 can be used for multiprocessor communication. In this case, the slave processors have bit SM20 in S0CON or SM21 in S1CON set to 1. When the master processor outputs slave's address, it sets the 9th bit to 1, causing a serial port receive interrupt in all the slaves. The slave processors compare the received byte with their network address. If there is a match, the addressed slave will clear SM20 or SM21 and receive the rest of the message, while other slaves will leave the SM20 or SM21 bit unaffected and ignore this message. After addressing the slave, the host will output the rest of the message with the 9th bit set to 0, so no serial port receive interrupt will be generated in unselected slaves. 44 Rev. 1.4 DS_1210F_001 1.7.7 73S1210F Data Sheet Timers and Counters The 80515 has two 16-bit timer/counter registers: Timer 0 and Timer 1. These registers can be configured for counter or timer operations. In timer mode, the register is incremented every machine cycle, meaning that it counts up after every 12 periods of the MPU clock signal. In counter mode, the register is incremented when the falling edge is observed at the corresponding input signal T0 or T1 (T0 and T1 are the timer gating inputs derived from USR[0:7] pins, see the User (USR) Ports section). Since it takes 2 machine cycles to recognize a 1-to-0 event, the maximum input count rate is 1/2 of the oscillator frequency. There are no restrictions on the duty cycle, however to ensure proper recognition of 0 or 1 state, an input should be stable for at least 1 machine cycle. Four operating modes can be selected for Timer 0 and Timer 1. Two Special Function Registers (TMOD and TCON) are used to select the appropriate mode. The Timer 0 load registers are designated as TL0 and TH0 and the Timer 1 load registers are designated as TL1 and TH1. Timer/Counter Mode Control Register (TMOD): 0x89 0x00 Table 40: The TMOD Register MSB LSB GATE C/T M1 M0 GATE C/T Timer 1 M1 M0 Timer 0 Bits TR1 and TR0 in the TCON register start their associated timers when set. Bit Symbol Function TMOD.7 TMOD.3 Gate If set, enables external gate control (USR pin(s) connected to T0 or T1 for Counter 0 or 1, respectively). When T0 or T1 is high, and TRx bit is set (see the TCON register), a counter is incremented every falling edge on T0 or T1 input pin. If not set, the TRx bit controls the corresponding timer. TMOD.6 TMOD.2 C/T Selects Timer or Counter operation. When set to 1, the counter operation is performed based on the falling edge of T0 or T1. When cleared to 0, the corresponding register will function as a timer. TMOD.5 TMOD.1 M1 Selects the mode for Timer/Counter 0 or Timer/Counter 1, as shown in the TMOD description. TMOD.4 TMOD.0 M0 Selects the mode for Timer/Counter 0 or Timer/Counter 1, as shown in the TMOD description. Table 41: Timers/Counters Mode Description M1 M0 Mode 0 0 Mode 0 13-bit Counter/Timer. 0 1 Mode 1 16-bit Counter/Timer. 1 0 Mode 2 8-bit auto-reload Counter/Timer. 1 1 Mode 3 If Timer 1 M1 and M0 bits are set to '1', Timer 1 stops. If Timer 0 M1 and M0 bits are set to '1', Timer 0 acts as two independent 8-bit Timer/Counters. Rev. 1.4 Function 45 73S1210F Data Sheet DS_1210F_001 Mode 0 Putting either timer/counter into mode 0 configures it as an 8-bit timer/counter with a divide-by-32 prescaler. In this mode, the timer register is configured as a 13-bit register. As the count rolls over from all 1's to all 0's, it sets the timer overflow flag TF0. The overflow flag TF0 then can be used to request an interrupt. The counted input is enabled to the timer when TRx = 1 and either GATE = 0 or TX = 1 (setting GATE = 1 allows the timer to be controlled by external input TX, to facilitate pulse width measurements). TRx are control bits in the special function register TCON; GATE is in TMOD. The 13-bit register consists of all 8 bits of TH1 and the lower 5 bits of TL0. The upper 3 bits of TL0 are indeterminate and should be ignored. Setting the run flag (TRx) does not clear the registers. Mode 0 operation is the same for timer 0 as for timer 1. Mode 1 Mode 1 is the same as mode 0, except that the timer register is run with all 16 bits. Mode 2 Mode 2 configures the timer register as an 8-bit counter (TLx) with automatic reload. The overflow from TLx not only sets TFx, but also reloads TLx with the contents of THx, which is preset by software. The reload leaves THx unchanged. Mode 3 Mode 3 has different effects on timer 0 and timer 1. Timer 1 in mode 3 simply holds its count. The effect is the same as setting TR1 = 0. Timer 0 in mode 3 establishes TL0 and TH0 as two separate counters. TL0 uses the timer 0 control bits: C/T, GATE, TR0, INT0, and TF0. TH0 is locked into a timer function (counting machine cycles) and takes over the use of TR1 and TF1 from timer 1. Thus, TH0 now controls the "timer 1" interrupt. Mode 3 is provided for applications requiring an extra 8-bit timer or counter. When timer 0 is in mode 3, timer 1 can be turned on and off by switching it out of and into its own mode 3, or can still be used by the serial channel as a baud rate generator, or in fact, in any application not requiring an interrupt from timer 1 itself. Timer/Counter Control Register (TCON): 0x88 0x00 Table 42: The TCON Register MSB LSB TF1 46 TR1 TF0 TR0 IE1 IT1 IE0 IT0 Bit Symbol Function TCON.7 TF1 Timer 1 overflow flag. TCON.6 TR1 Not used for interrupt control. TCON.5 TF0 Timer 0 overflow flag. TCON.4 TR0 Not used for interrupt control. TCON.3 IE1 Interrupt 1 edge flag is set by hardware when the falling edge on external interrupt int1 is observed. Cleared when an interrupt is processed. TCON.2 IT1 Interrupt 1 type control bit. 1 selects falling edge and 0 selects low level for input pin to cause an interrupt. TCON.1 IE0 Interrupt 0 edge flag is set by hardware when the falling edge on external interrupt int0 is observed. Cleared when an interrupt is processed. TCON.0 IT0 Interrupt 0 type control bit. 1 selects falling edge and 0 sets low level for input pin to cause interrupt. Rev. 1.4 DS_1210F_001 1.7.8 73S1210F Data Sheet WD Timer (Software Watchdog Timer) The software watchdog timer is a 16-bit counter that is incremented once every 24 or 384 clock cycles. After a reset, the watchdog timer is disabled and all registers are set to zero. The watchdog consists of a 16-bit counter (WDT), a reload register (WDTREL), prescalers (by 2 and by 16), and control logic. Once the watchdog starts, it cannot be stopped unless the internal reset signal becomes active. WD Timer Start Procedure: The WDT is started by setting the SWDT flag. When the WDT register enters the state 0x7CFF, an asynchronous WDTS signal will become active. The signal WDTS sets bit 6 in the IP0 register and requests a reset state. WDTS is cleared either by the reset signal or by changing the state of the WDT timer. Refreshing the WD Timer: The watchdog timer must be refreshed regularly to prevent the reset request signal from becoming active. This requirement imposes an obligation on the programmer to issue two instructions. The first instruction sets WDT and the second instruction sets SWDT. The maximum delay allowed between setting WDT and SWDT is 12 clock cycles. If this period has expired and SWDT has not been set, WDT is automatically reset, otherwise the watchdog timer is reloaded with the content of the WDTREL register and WDT is automatically reset. Interrupt Enable 0 Register (IEN0): 0xA8 0x00 Table 43: The IEN0 Register MSB LSB EAL WDT ET2 ES0 ET1 Bit Symbol IEN0.7 EAL EAL = 0 - disable all interrupts. IEN0.6 WDT Watchdog timer refresh flag. EX1 ET0 EX0 Function Set to initiate a refresh of the watchdog timer. Must be set directly before SWDT is set to prevent an unintentional refresh of the watchdog timer. WDT is reset by hardware 12 clock cycles after it has been set. IEN0.5 - IEN0.4 ES0 ES0 = 0 - disable serial channel 0 interrupt. IEN0.3 ET1 ET1 = 0 - disable timer 1 overflow interrupt. IEN0.2 EX1 EX1 = 0 - disable external interrupt 1. IEN0.1 ET0 ET0 = 0 - disable timer 0 overflow interrupt. IEN0.0 EX0 EX0 = 0 - disable external interrupt 0. Rev. 1.4 47 73S1210F Data Sheet DS_1210F_001 Interrupt Enable 1 Register (IEN1): 0xB8 0x00 Table 44: The IEN1 Register MSB LSB - SWDT EX6 EX5 EX4 EX3 Bit Symbol IEN1.7 - IEN1.6 SWDT IEN1.5 EX6 EX6 = 0 - disable external interrupt 6. IEN1.4 EX5 EX5 = 0 - disable external interrupt 5. IEN1.3 EX4 EX4 = 0 - disable external interrupt 4. IEN1.2 EX3 EX3 = 0 - disable external interrupt 3. IEN1.1 EX2 EX2 = 0 - disable external interrupt 2. IEN1.0 - EX2 - Function Watchdog timer start/refresh flag. Set to activate/refresh the watchdog timer. When directly set after setting WDT, a watchdog timer refresh is performed. Bit SWDT is reset by the hardware 12 clock cycles after it has been set. Interrupt Priority 0 Register (IP0): 0xA9 0x00 Table 45: The IP0 Register MSB - LSB WDTS IP0.5 IP0.4 IP0.3 IP0.2 IP0.1 IP0.0 Bit Symbol Function IP0.6 WDTS Watchdog timer status flag. Set when the watchdog timer has expired. The internal reset will be generated, but this bit will not be cleared by the reset. This allows the user program to determine if the watchdog timer caused the reset to occur and respond accordingly. Can be read and cleared by software. Note: The remaining bits in the IP0 register are not used for watchdog control. Watchdog Timer Reload Register (WDTREL): 0x86 0x00 Table 46: The WDTREL Register MSB LSB WDPSEL WDREL6 WDREL5 WDREL4 WDREL3 WDREL2 WDREL1 WDREL0 Bit Symbol WDTREL.7 WDPSEL WDTREL.6 to WDTREL.0 48 Function Prescaler select bit. When set, the watchdog is clocked through an additional divide-by-16 prescaler. Seven bit reload value for the high-byte of the watchdog timer. This value is WDREL6-0 loaded to the WDT when a refresh is triggered by a consecutive setting of bits WDT and SWDT. Rev. 1.4 DS_1210F_001 1.7.9 73S1210F Data Sheet User (USR) Ports The 73S1210F includes 8 pins of general purpose digital I/O (GPIO). On reset or power-up, all USR pins are inputs until they are configured for the desired direction. The pins are configured and controlled by the USR70 and UDIR70 SFRs. Each pin declared as USR can be configured independently as an input or output with the bits of the UDIR70 register. Table 47 lists the direction registers and configurability associated with each group of USR pins. USR pins 0 to 7 are multiple use pins that can be used for general purpose I/O, external interrupts and timer control. Table 48 shows the configuration for a USR pin through its associated bit in its UDIR register. Values read from and written into the GPIO ports use the data registers USR70. Note: After reset, all USR pins are defaulted as inputs and pulled up to VDD until any write to the corresponding UDIR register is performed. This insures all USR pins are set to a known value until set by the firmware. Unused USR pins can be set for output if unused and unconnected to prevent them from floating. Alternatively, unused USR pins can be set for input and tied to ground or VDD. Table 47: Direction Registers and Internal Resources for DIO Pin Groups USR Pin Group Type USR_0...USR_7 Multi-use Direction Register Name Direction Register (SFR) Location Data Register Name Data Register (SFR) Location UDIR70 0x91 [7:0] USR70 0x90 [7:0] Table 48: UDIR Control Bit UDIR Bit USR Pin Function 0 1 output input Four XRAM SFR registers (USRIntTCtl0, USRIntTCtl1, USRIntTCtl2, and USRIntTCtl3) control the use of the USR [7:0] pins. Each of the USR [7:0] pins can be configured as GPIO or individually be assigned an internal resource such as an interrupt or a timer/counter control. Each of the four registers contains two 3-bit configuration words named UxIS (where x corresponds to the USR pin). The control resources selectable for the USR pins are listed in Table 50 through Table 53. If more than one input is connected to the same resource, the resources are combined using a logical OR. Table 49: Selectable Controls Using the UxIS Bits UxIS Value Resource Selected for USRx Pin 0 None 1 None 2 T0 (counter0 gate/clock) 3 T1 (counter1 gate/clock) 4 Interrupt 0 rising edge/high level on USRx 5 Interrupt 1 rising edge/high level on USRx 6 7 Interrupt 0 falling edge/low level on USRx Interrupt 1 falling edge/low level on USRx Note: x denotes the corresponding USR pin. Interrupt edge or level control is assigned in the IT0 and IT1 bits in the TCON register. Rev. 1.4 49 73S1210F Data Sheet DS_1210F_001 External Interrupt Control Register (USRIntCtl1) : 0xFF90 0x00 Table 50: The USRIntCtl1 Register MSB - LSB U1IS.6 U1IS.5 U1IS.4 - U0IS.2 U0IS.1 U0IS.0 External Interrupt Control Register (USRIntCtl2) : 0xFF91 0x00 Table 51: The USRIntCtl2 Register MSB - LSB U3IS.6 U3IS.5 U3IS.4 - U2IS.2 U2IS.1 U2IS.0 External Interrupt Control Register (USRIntCtl3) : 0xFF92 0x00 Table 52: The USRIntCtl3 Register MSB - LSB U5IS.6 U5IS.5 U5IS.4 - U4IS.2 U4IS.1 U4IS.0 External Interrupt Control Register (USRIntCtl4) : 0xFF93 0x00 Table 53: The USRIntCtl4 Register MSB - 50 LSB U7IS.6 U7IS.5 U7IS.4 - U6IS.2 U6IS.1 U6IS.0 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 1.7.10 Analog Voltage Comparator The 73S1210F includes a programmable comparator that is connected to the ANA_IN pin. The comparator can be configured to trigger an interrupt if the input voltage rises above or falls below a selectable threshold voltage. The comparator control register should not be modified when the analog interrupt (ANAIEN bit in the INT6Ctl register) is enabled to guard against any false interrupt that might be generated when modifying the threshold. The comparator has a built-in hysteresis to prevent the comparator from repeatedly responding to low-amplitude noise. This hysteresis is approximately 20mV. Interrupt control is handled in the INT6Ctl register. Analog Compare Control Register (ACOMP): 0xFFD0 0x00 Table 54: The ACOMP Register MSB LSB ANALVL - ONCHG CPOL CMPEN TSEL.2 TSEL.1 TSEL.0 Bit Symbol ACOMP.7 ANALVL ACOMP.6 - ACOMP.5 ONCHG If set, the Ana_interrupt is invoked on any change above or below the threshold, bit 4 is ignored. ACOMP.4 CPOL If set = 1, Ana_interrupt is invoked when signal rises above selected threshold. If set = 0, Ana_interrupt is invoked when signal goes below selected threshold (default). ACOMP.3 CMPEN Enables power to the analog comparator. 1 = Enabled. 0 = Disabled (default). ACOMP.2 TSEL.2 Sets the voltage threshold for comparison to the voltage on pin ANA_IN. Thresholds are as follows: ACOMP.1 TSEL.1 ACOMP.0 TSEL.0 Rev. 1.4 Function When read, indicates whether the input level is above or below the threshold. This is a real time value and is not latched, so it may change from the time of the interrupt trigger until read. TSEL.2 0 0 0 0 1 1 1 1 TSEL.1 0 0 1 1 0 0 1 1 TSEL.0 0 1 0 1 0 1 0 1 Voltage Threshold 1.00V 1.24V 1.40V 1.50V 1.75V 2.00V 2.30V 2.50V 51 73S1210F Data Sheet DS_1210F_001 External Interrupt Control Register (INT6Ctl): 0xFF95 0x00 Table 55: The INT6Ctl Register MSB LSB - - VFTIEN VFTINT I2CIEN I2CINT ANIEN ANINT Bit Symbol INT6Ctl.7 - INT6Ctl.6 - INT6Ctl.5 VFTIEN VDD fault interrupt enable. INT6Ctl.4 VFTINT VDD fault interrupt flag. INT6Ctl.3 I2CIEN I2C interrupt enabled. INT6Ctl.2 I2CINT I2C interrupt flag. INT6Ctl.1 ANIEN If ANIEN = 1 Analog Compare event interrupt is enabled. When masked (ANIEN = 0), ANINT (bit 0) may be set, but no interrupt is generated. INT6Ctl.0 ANINT (Read Only) Set when the selected ANA_IN signal changes with respect to the selected threshold if Compare_Enable is asserted. Cleared on read of register. 52 Function Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 1.7.11 LED Driver The 73S1210F provides a single dedicated output pin for driving an LED. The LED driver pin can be configured as a current source that will pull to ground to drive an LED that is connected to VDD without the need for an external current limiting resistor. This pin may be used as general purpose output with the programmed pull-down current and a strong (CMOS) pull-up, if enabled. The analog block must be enabled when this output is being used to drive the selected output current. This pin may be used as an input with consideration of the programmed output current and level. The register bit when read, indicates the state of the pin. LED Control Register (LEDCtl): 0xFFF3 0xFF Table 56: The LEDCtl Register MSB LSB - LPUEN ISET.1 ISET.0 - - - LEDD0 Bit Symbol LEDCtl.7 - LEDCtl.6 LPUEN 0 = Pull-ups are enabled for all of the LED pins. LEDCtl.5 ISET.1 These two bits control the drive current (to ground) for the LED driver pin. Current levels are: LEDCtl.4 ISET.0 LEDCtl.3 - LEDCtl.2 - LEDCtl.1 - LEDCtl.0 LEDD0 Rev. 1.4 Function 00 = 0ma(off) 01 = 2ma 10 = 4ma 11 = 10ma Write data controls output level of pin LED0. Read will report level of pin LED0. 53 73S1210F Data Sheet DS_1210F_001 1.7.12 I2C Master Interface The 73S1210F includes a dedicated fast mode, 400kHz I2C Master interface. The I2C interface can read or write 1 or 2 bytes of data per data transfer frame. The MPU communicates with the interface through six dedicated SFR registers: * * * * * * Device Address (DAR) Write Data (WDR) Secondary Write Data (SWDR) Read Data (RDR) Secondary Read Data (SRDR) Control and Status (CSR) The DAR register is used to set up the slave address and specify if the transaction is a read or write operation. The CSR register sets up, starts the transaction and reports any errors that may occur. When the I2C transaction is complete, the I2C interrupt is reported via external interrupt 6. The I2C interrupt is automatically de-asserted when a subsequent I2C transaction is started. The I2C interface uses a 400kHz clock from the time-base circuits. 1.7.12.1 I2C Write Sequence To write data on the I2C Master Bus, the 80515 has to program the following registers according to the following sequence: 1. Write slave device address to Device Address register (DAR). The data contains 7 bits for the slave device address and 1 bit of op-code. The op-code bit should be written with a 0 to indicate a write operation. 2. Write data to Write Data register (WDR). This data will be transferred to the slave device. 3. If writing 2 bytes, set bit 0 of the Control and Status register (CSR) and load the second data byte to Secondary Write Data register (SWDR). 4. Set bit 1 of the CSR register to start I2C Master Bus. 5. Wait for I2C interrupt to be asserted. It indicates that the write on I2C Master Bus is done. Refer to information about the INT6Ctl, IEN1 and IRCON register for masking and flag operation. Figure 10 shows the timing of the I2C write mode: 54 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Transfer length (CSR bit0) Start I2C (CSR bit1) I2C_Interrupt SDA Device Address [7:0] MSB Write Data [7:0 LSB MSB LSB SCL 1-7 8 9 10-17 18 ACK bit ACK bit START condition STOP condition Transfer length (CSR bit0) Start I2C (CSR bit1) I2C_Interrupt SDA Device Address [7:0] MSB Secondary Write Data [7:0] Write Data [7:0] LSB MSB MSB LSB LSB SCL 1-7 8 9 ACK bit 10-17 18 ACK bit START condition 19-26 27 ACK bit STOP condition Figure 10: I2C Write Mode Operation 1.7.12.2 I2C Read Sequence To read data on the I2C Master Bus from a slave device, the 80515 has to program the following registers in this sequence: 1. Write slave device address to Device Address register (DAR). The data contains 7 bits device address and 1 bit of op-code. The op-code bit should be written with a 1. 2. Write control data to Control and Status register. Write a 1 to bit 1 to start I2C Master Bus. Also write a 1 to bit 0 if the Secondary Read Data register (SRDR) is to be captured from the I2C Slave device. 3. Wait for I2C interrupt to be asserted. It indicates that the read operation on the I2C bus is done. Refer to information about the INT6Ctl, IEN1 and IRCON registers for masking and flag operation. 4. Read data from the Read Data register (RDR). 5. Read data from Secondary Read Data register (SRDR) if bit 0 of Control and Status register (CSR) is written with a 1. Rev. 1.4 55 73S1210F Data Sheet DS_1210F_001 Figure 11 shows the timing of the I2C read mode: Transfer length (CSR bit0) Start I2C (CSR bit1) I2c_Interrupt SDA Device Address [7:0] MSB Read Data [7:0 LSB MSB LSB SCL 1-7 8 9 10-17 18 ACK bit No ACK bit START condition STOP condition Transfer length (CSR bit0) Start I2C (CSR bit1) I2c_Interrupt SDA Device Address [7:0] MSB Secondary Read Data[7:0] Read Data [7:0] LSB MSB LSB SCL 1-7 START condition 8 9 ACK bit 10-17 18 ACK bit 19-26 27 No ACK bit STOP condition Figure 11: I2C Read Operation 56 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Device Address Register (DAR): 0xFF80 0x00 Table 57: The DAR Register MSB LSB DVADR.6 Bit DVADR.5 DVADR.4 DVADR.3 DVADR.2 Symbol DVADR.1 DVADR.0 I2CRW Function DAR.7 DAR.6 DAR.5 DAR.4 DVADR [0:6] Slave device address. I2CRW If set = 0, the transaction is a write operation. If set=1, read. DAR.3 DAR.2 DAR.1 DAR.0 I2C Write Data Register (WDR): 0XFF81 0x00 Table 58: The WDR Register MSB WDR.7 Bit LSB WDR.6 WDR.5 WDR.4 WDR.3 WDR.2 WDR.1 WDR.0 Function WDR.7 WDR.6 WDR.5 WDR.4 WDR.3 Data to be written to the I2C slave device. WDR.2 WDR.1 WDR.0 Rev. 1.4 57 73S1210F Data Sheet DS_1210F_001 I2C Secondary Write Data Register (SWDR): 0XFF82 0x00 Table 59: The SWDR Register MSB SWDR.7 LSB SWDR.6 SWDR.5 SWDR.4 Bit SWDR.3 SWDR.2 SWDR.1 SWDR.0 Function SWDR.7 SWDR.6 SWDR.5 SWDR.4 SWDR.3 Second Data byte to be written to the I2C slave device if bit 0 (I2CLEN) of the Control and Status register (CSR) is set = 1. SWDR.2 SWDR.1 SWDR.0 I2C Read Data Register (RDR): 0XFF83 0x00 Table 60: The RDR Register MSB RDR.7 Bit LSB RDR.6 RDR.5 RDR.4 RDR.3 RDR.2 RDR.1 RDR.0 Function RDR.7 RDR.6 RDR.5 RDR.4 RDR.3 Data read from the I2C slave device. RDR.2 RDR.1 RDR.0 58 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet I2C Secondary Read Data Register (SRDR): 0XFF84 0x00 Table 61: The SRDR Register MSB LSB SRDR.7 SRDR.6 SRDR.5 SRDR.4 Bit SRDR.3 SRDR.2 SRDR.1 SRDR.0 Function SRDR.7 SRDR.6 SRDR.5 SRDR.4 SRDR.3 Second Data byte to be read from the I2C slave device if bit 0 (I2CLEN) of the Control and Status register (CSR) is set = 1. SRDR.2 SRDR.1 SRDR.0 I2C Control and Status Register (CSR): 0xFF85 0x00 Table 62: The CSR Register MSB LSB - - - - - AKERR I2CST I2CLEN Bit Symbol CSR.7 - CSR.6 - CSR.5 - CSR.4 - CSR.3 - CSR.2 AKERR Set to 1 if acknowledge bit from Slave Device is not 0. Automatically reset when the new bus transaction is started. CSR.1 I2CST Write a 1 to start I2C transaction. Automatically reset to 0 when the bus transaction is done. This bit should be treated as a "busy" indicator on reading. If it is high, the serial read/write operations are not completed and no new address or data should be written. CSR.0 I2CLEN Set to 1 for 2 byte read or write operations. Set to 0 for 1-byte operations. Rev. 1.4 Function 59 73S1210F Data Sheet DS_1210F_001 External Interrupt Control Register (INT6Ctl): 0xFF95 0x00 Table 63: The INT6Ctl Register MSB LSB - - VFTIEN VFTINT I2CIEN I2CINT ANIEN ANINT Bit Symbol INT6Ctl.7 - INT6Ctl.6 - INT6Ctl.5 VFTIEN VDD fault interrupt enable. INT6Ctl.4 VFTINT VDD fault interrupt flag. INT6Ctl.3 I2CIEN When set = 1, the I2C interrupt is enabled. INT6Ctl.2 I2CINT When set = 1, the I2C transaction has completed. Cleared upon the start of a subsequent I2C transaction. INT6Ctl.1 ANIEN Analog compare interrupt enable. INT6Ctl.0 ANINT Analog compare interrupt flag. 60 Function Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 1.7.13 Keypad Interface The 73S1210F supports a 30-button (6 rows x 5 columns) keypad (SPST Mechanical Contact Switches) interface using 11 dedicated I/O pins. Figure 12 shows a simplified block diagram of the keypad interface. KORDERL / H Registers 7 6 6 5 5 4 4 3 3 2 2 Column Scan Order 7 1 7 6 5 4 3 2 1 0 0 pull-up VDD Keypad Clock Column Value 5 1 COL4:0 Scan 0 VDD KSIZE Register 6 5 4 3 2 1 0 pullup 7 ROW5:0 KCOL Register(1) Keypad Clock Row Value 6 7 6 5 4 3 2 1 Debouncing 0 7 6 5 4 3 2 1 If smaller keypad than 6 x 5 is to be implemented, unused row inputs should be connected to VDD. Unused column outputs should be left unconnected. Debounce Time Key_Detect Hardware Scan Enable Key_Detect_Enable KROW Register 0 6 KSTAT Register Scan Time 0 73S1210F Dividers 1 2 3 4 5 6 7 KSCAN Register 1kHz (1) KCOL is normally used as Read only register. When hardware keyscan mode is disabled, this register is to be used by firmware to write the column data to handle firmware scanning. Figure 12: Simplified Keypad Block Diagram There are five drive lines (outputs) corresponding to columns and 6 sense lines (inputs) corresponding to rows. Hysteresis and pull-ups are provided on all inputs (rows), which eliminate the need for external resistors in the keypad. Key scanning happens by asserting one of the 5 column lines low and looking for a low on a sense line indicating that a key is pressed (switch closed) at the intersection of the drive/sense (column/row) line in the keypad. Key detection is performed by hardware with an incorporated debounce timer. Debouncing time is adjustable through the KSCAN register. Internal hardware circuitry performs column scanning at an adjustable scanning rate and column scanning order through registers KSCAN and KORDERL / KORDERH. Key scanning is disabled at reset and must be enabled by firmware. When a valid key is detected, an interrupt is generated and the valid value of the pressed key is automatically Rev. 1.4 61 73S1210F Data Sheet DS_1210F_001 written into the KCOL and KROW registers. The keypad interface uses a 1kHz clock derived from the 12MHz crystal. The clock is enabled by setting bit 6 - KBEN - in the MCLKCtl register (see the Oscillator and Clock Generation section) to carry out scanning and debouncing. The keypad size can be adjusted within the KSIZE register. Normal scanning is performed by hardware when the SCNEN bit is set at 1 in the KSTAT register. Figure 13 shows the flowchart of how the hardware scanning operates. In order to minimize power, scanning does not occur until a key-press is detected. Once hardware key scanning is enabled, the hardware drives all column outputs low and waits for a low to be detected on one of the inputs. When a low is detected on any row, and before key scanning starts, the hardware checks that the low level is still detected after a debounce time. The debounce time is defined by firmware in the KSCAN register (bits 7:0, DBTIME). Debounce times from 4ms to 256ms in 4ms increments are supported. If a key is not pressed after the debounce time, the hardware will go back to looking for any input to be low. If a key is confirmed to be pressed, key scanning begins. Key scanning asserts one of the 5 drive lines (COL 4:0) low and looks for a low on a sense line indicating that a key is pressed at the intersection of the drive/sense line in the keypad. After all sense lines have been checked without a key-press being detected, the next column line is asserted. The time between checking each sense line is the scan time and is defined by firmware in the KSCAN register (bits 0:1 - SCTIME). Scan times from 1ms to 4ms are supported. Scanning order does not affect the scan time. This scanning continues until the entire keypad is scanned. If only one key is pressed, a valid key is detected. Simultaneous key presses are not considered as valid (If two keys are pressed, no key is reported to firmware). Possible scrambling of the column scan order is provided by means of the KORDERL and KORDERH registers that define the order of column scanning. Values in these registers must be updated every time a new keyboard scan order is desired. It is not possible to change the order of scanning the sense lines. The column and row intersection for the detected valid key are stored in the KCOL and KROW registers. When a valid key is detected, an interrupt is generated. Firmware can then read those registers to determine which key had been pressed. After reading the KCOL and KROW registers, the firmware can update the KORDERL / KORDERH registers if a new scan order is needed. When the SCNEN bit is enabled in the KSTAT register, the KCOL and KROW registers are only updated after a valid key has been identified. The hardware does not wait for the firmware to service the interrupt in order to proceed with the key scanning process. Once the valid key (or invalid key - e.g. two keys pressed) is detected, the hardware waits for the key to be released. Once the key is released, the debounce timer is started. If the key is not still released after the debounce time, the debounce counter starts again. After a key release, all columns will be driven low as before and the process will repeat waiting for any key to be pressed. When the SCNEN bit is disabled, all drive outputs are set to the value in the KCOL register. If firmware clears the SCNEN bit in the middle of a key scan, the KCOL register contains the last value stored in there which will then be reflected on the output pins. A bypass mode is provided so that the firmware can do the key scanning manually (SCNEN bit must be cleared). In bypass mode, the firmware writes/reads the Column and Row registers to perform the key scanning. 62 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet KSTAT Register: Enable HW Scanning Enable Keypad Interrupt Keypad Initialization All Column Outputs = 0 Any Row Input = 0 ? No Yes No Deboucing Timer KSCAN Register: Debouncing Time Any Row Input still = 0 ? KSIZE Register: Keypad Size Definition KORDERL / H Registers: Column Scan Order Keypad Scanning KSCAN Register: Scanning Rate How Many keys have been detected? More than 1 key 0 key 1 key Download of the key row and column values in KROW and KCOL registers Keypad Interrupt generation KCOL Register: Value of the valid key column KROW Register: Value of the valid key row KSTAT Register: Key Detect Interrupt No Deboucing Timer Is (are) the key(s) released ? (*) Yes No Is (are) the key(s) still released ? (*) Yes KSCAN Register: Debouncing Time Register Used to Control the hardware keypad interface Register written by the hardware keypad interface (*) Key release is cheked by looking for a low level on any row. Figure 13: Keypad Interface Flow Chart Rev. 1.4 63 73S1210F Data Sheet DS_1210F_001 Keypad Column Register (KCOL): 0xD1 0x1F This register contains the value of the column of a key detected as valid by the hardware. In bypass mode, this register firmware writes directly this register to carry out manual scanning. Table 64: The KCOL Register MSB LSB - - Bit Symbol KCOL.7 - KCOL.6 - KCOL.5 - KCOL.4 COL.4 KCOL.3 COL.3 KCOL.2 COL.2 KCOL.1 COL.1 KCOL.0 COL.0 - COL.4 COL.3 COL.2 COL.1 COL.0 Function Drive lines bit mapped to corresponding with pins COL(4:0). When a key is detected, firmware reads this register to determine column. In bypass (S/W keyscan) mode, Firmware writes this register directly. 0x1E = COL(0) low, all others high. 0x0F = COL(4) low, all others high. 0x1F = COL(4:0) all high. Keypad Row Register (KROW): 0xD2 0x3F This register contains the value of the row of a key detected as valid by the hardware. In bypass mode, this register firmware reads directly this register to carry out manual detection. Table 65: The KROW Register MSB LSB - 64 - Bit Symbol KROW.7 - KROW.6 - KROW.5 ROW.6 KROW.4 ROW.4 KROW.3 ROW.3 KROW.2 ROW.2 KROW.1 ROW.1 KROW.0 ROW.0 ROW.5 ROW.4 ROW.3 ROW.2 ROW.1 ROW.0 Function Sense lines bit mapped to correspond with pins ROW(5:0). When key detected, firmware reads this register to determine row. In bypass mode, firmware reads rows and has to determine if there was a key press or not. 0x3E = ROW(0) low, all others high. 0x1F = ROW(5) low, all others high. 0x3F = ROW(5:0) all high. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Keypad Scan Time Register (KSCAN): 0xD3 0x00 This register contains the values of scanning time and debouncing time. Table 66: The KSCAN Register MSB LSB DBTIME.5 DBTIME.4 DBTIME.3 DBTIME.2 DBTIME.1 DBTIME.0 SCTIME.1 SCTIME.0 Bit Symbol KSCAN.7 DBTIME.5 KSCAN.6 DBTIME.4 KSCAN.5 DBTIME.3 KSCAN.4 DBTIME.2 KSCAN.3 DBTIME.1 KSCAN.2 DBTIME.0 KSCAN.1 SCTIME.1 KSCAN.0 SCTIME.0 Function Debounce time in 4ms increments. 1 = 4ms de-bounce time, 0x3F = 252ms, 0x00 = 256ms. Key presses and key releases are debounced by this amount of time. Scan time in ms. 01 = 1ms, 02 = 2ms, 00 = 3ms, 00 = 4ms. Time between checking each key during keypad scanning. Keypad Control/Status Register (KSTAT): 0xD4 0x00 This register is used to control the hardware keypad scanning and detection capabilities, as well as the keypad interrupt control and status. Table 67: The KSTAT Register MSB LSB - - - - KEYCLK HWSCEN KEYDET KYDTEN Bit Symbol KSTAT.7 - KSTAT.6 - KSTAT.5 - KSTAT.4 - KSTAT.3 KEYCLK The current state of the keyboard clock can be read from this bit. KSTAT.2 HWSCEN Hardware Scan Enable - When set, the hardware will perform automatic key scanning. When cleared, the firmware must perform the key scanning manually (bypass mode). KSTAT.1 KEYDET Key Detect - When HWSCEN = 1, this bit is set causing an interrupt that indicates a valid key press was detected and the key location can be read from the Keypad Column and Row registers. When HWSCEN = 0, this bit is an interrupt which indicates a falling edge on any Row input if all Row inputs had been high previously (note: multiple Key Detect interrupts may occur in this case due to the keypad switch bouncing). In all cases, this bit is cleared when read. When HWSCEN = 0 and the keypad interface 1kHz clock is disabled, a key press will still set this bit and cause an interrupt. KSTAT.0 KYDTEN Key Detect Enable - When set, the KEYDET bit can cause an interrupt and when cleared the KEYDET cannot cause an interrupt. KEYDET can still get set even if the interrupt is not enabled. Rev. 1.4 Function 65 73S1210F Data Sheet DS_1210F_001 Keypad Scan Time Register (KSIZE): 0xD5 0x00 This register is not applicable when HWSCEN is not set. Unused row inputs should be connected to VDD. Table 68: The KSIZE Register MSB 66 LSB - - ROWSIZ.2 Bit Symbol KSIZE.7 - KSIZE.6 - KSIZE.5 ROWSIZ.2 KSIZE.4 ROWSIZ.1 KSIZE.3 ROWSIZ.0 KSIZE.2 COLSIZ.2 KSIZE.1 COLSIZ.1 KSIZE.0 COLSIZ.0 ROWSIZ.1 ROWSIZ.0 COLSIZ.2 COLSIZ.1 COLSIZ.0 Function Defines the number of rows in the keypad. Maximum number is 6 given the number of row pins on the package. Allows for a reduced keypad size for scanning. Defines the number of columns in the keypad. Maximum number is 5 given the number of column pins on the package. Allows for a reduced keypad size for scanning. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Keypad Column LS Scan Order Register (KORDERL): 0xD6 0x00 In the KORDERL and KORDERH registers, Column Scan Order(14:0) is grouped into 5 sets of 3 bits each. Each set determines which column (COL(4:0) pin) to activate by loading the column number into the 3 bits. When in HW_Scan_Enable mode, the hardware will step through the sets from 1Col to 5Col (up to the number of columns in Colsize) and scan the column defined in the 3 bits. To scan in sequential order, set a counting pattern with 0 in set 0, and 1 in set 1,and 2 in set 2, and 3 in set 3, and 4 in set 4. The firmware should update this as part of the interrupt service routine so that the new scan order is loaded prior to the next key being pressed. For example, to scan COL(0) first, 1Col(2:0) should be loaded with 000'b. To scan COL(4) fifth, 5Col(2:0) should be loaded with 100'b. Table 69: The KORDERL Register MSB LSB 3COL.1 3COL.0 Bit Symbol KORDERL.7 3COL.1 KORDERL.6 3COL.0 KORDERL.5 2COL.2 KORDERL.4 2COL.1 KORDERL.3 2COL.0 KORDERL.2 1COL.2 KORDERL.1 1COL.1 KORDERL.0 1COL.0 2COL.2 2COL.1 2COL.0 1COL.2 1COL.1 1COL.0 Function Column to scan 3rd (lsb's). Column to scan 2nd. Column to scan 1st. Keypad Column MS Scan Order Register (KORDERH): 0xD7 0x00 Table 70: The KORDERH Register MSB LSB - 5COL.2 Bit Symbol KORDERH.7 - KORDERH.6 5COL.2 KORDERH.5 5COL.1 KORDERH.4 5COL.0 KORDERH.3 4COL.2 KORDERH.2 4COL.1 KORDERH.1 4COL.0 KORDERH.0 3COL.2 Rev. 1.4 5COL.1 5COL.0 4COL.2 4COL.1 4COL.0 3COL.2 Function Column to scan 5th. Column to scan 4th. Column to scan 3rd (msb). 67 73S1210F Data Sheet DS_1210F_001 External Interrupt Control Register (INT5Ctl): 0xFF94 0x00 Table 71: The INT5Ctl Register MSB LSB PDMUX - - - - - KPIEN KPINT Bit Symbol Function INT5Ctl.7 PDMUX INT5Ctl.6 - INT5Ctl.5 - INT5Ctl.4 - INT5Ctl.3 - INT5Ctl.2 - INT5Ctl.1 KPIEN Enables Keypad interrupt when set = 1. INT5Ctl.0 KPINT This bit indicates the Keypad logic has set Key_Detect bit and a key location may be read. Cleared on read of register. Power down multiplexer control. 1.7.14 Emulator Port The emulator port, consisting of the pins E_RST, E_TCLK and E_RXTX, provides control of the MPU through an external in-circuit emulator. The E_TBUS[3:0] pins, together with the E_ISYNC/BRKRQ, add trace capability to the emulator. The emulator port is compatible with the ADM51 emulators manufactured by Signum SystemsTM. The signals of the emulator port have weak pull-ups. Adding resistor footprints for signals E_RST, E_TCLK and E_RXTX on the PCB is recommended. If necessary, adding 10k pull-up resistors on E_TCLK and E_RXTX and a 3k on E_RST will help the emulator operate normally if a problem arises. If code trace capability is needed on this interface, 20pF capacitors ( (to ground) need to be added to allow the trace function capability to run properly. These capacitors should be attached to the TBUS0:3 and ISBR signals. 68 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 1.7.15 Smart Card Interface Function The 73S1210F integrates one ISO-7816 (T=0, T=1) UART, one complete ICC electrical interface as well as an external smart card interface to allow multiple smart cards to be connected using the Teridian 8010 family of interface devices. Figure 14 shows the simplified block diagram of the card circuitry (UART + interfaces), with detail of dedicated XRAM registers. ICC Event SCInt SCIE Card Interrupt Management ICC Pwr_event Card Insertion SParCtl Serial UART SByteCtl SCCtl UART T=0 T=1 SCPrtcol STXCtl RX Direct Mode SCECtl 2-Byte Tx FIFO Card and Mode Selection SRXData Bypass Mode SRXCtl Activation / Deactivation Sequencer VCC Card Generation VCC Buffer / Level Shifter I/O ICC#1 STXData 2-Byte Rx FIFO VccCtl/ VccTMR TX SCSel I/OExt. ICC FDReg I/O Buffer / Level Shifter RST Buffer / Level Shifter SCCLK/SCSCLK CLK BGT/EGT BGT0/1/2/3/ CWT0/1 ATRMsB/LsB PRES Buffer / Level Shifter Timers C4 STSTO Buffer / Level Shifter RLength C8 SCDir SCCLK CLK ICC 7.2MHz Card Clock Management Internal ICC Interface CLKExt. ICC SIO SCLK XRAM Registers SCSCLK SCCLK/ SCSCLK External ICC Interface Figure 14: Smart Card Interface Block Diagram Card interrupts are managed through two dedicated registers: SCIE (Interrupt Enable to define which interrupt is enabled) and SCInt (Interrupt status). They allow the firmware to determine the source of an interrupt, that can be a card insertion / removal, card power fault, or a transmission (TX) or reception (RX) event / fault. It should be noted that even when card clock is disabled, an ICC interrupt can be generated Rev. 1.4 69 73S1210F Data Sheet DS_1210F_001 on a card insertion / removal to allow power saving modes. Card insertion / removal is generated from the respective card switch detection inputs (whose polarity is programmable). The built-in ICC Interface has a linear regulator (VCC generator) capable of driving 1.8, 3.0 and 5.0V smart cards in accordance with the ISO 7816-3 and EMV4.1 standards. This converter uses the VP (5.5V nominal) input supply source. See the power supply management section above for more detail. Auxiliary I/O lines C4 and C8 are only provided for the built-in interface. If support for the auxiliary lines is necessary for the external smart card interface, they need to be handled manually through the USR GPIO pins. The external 73S8010x devices directly connect the I/O (SIO) and clock (SCLK) signals and control is handled via the I2C interface. Figure 15 shows how multiple 8010 devices can be connected to the 73S1210F. VPC VPC PRES PRES VCC RST CLK C4 C8 I/O GND SC1 SIO SCLK 73S1210F INT PRES SCL 73S8010 SC(n) SDA IOUC XTALIN SAD(0:2) INT PRES SCL SDA 73S8010 SC3 IOUC XTALIN SAD(0:2) INT INT3 SCL SDA SDA SCL IOUC XTALIN SAD(0:2) PRES 73S8010 SC2 Figure 15: External Smart Card Interface Block Diagram 70 Rev. 1.4 DS_1210F_001 1.7.15.1 73S1210F Data Sheet ISO 7816 UART An embedded ISO 7816 (hardware) UART is provided to control communications between a smart card and the 73S1210F MPU. The UART can be shared between the one built-in ICC interface and the external ICC interface. Selection of the desired interface is made by register SCSel. Control of the external interface is handled by the I2C interface for any external 73S8010x device. The following is a list of features for the ISO 7816 UART: * * * * * * * * * * * * Two-byte FIFO for temporary data storage on both TX and Rx data. Parity checking in T=0. This feature can be enabled/disabled by firmware. Parity error reporting to firmware and Break generation to ICC can be controlled independently. Parity error generation for test purposes. Retransmission of last byte if ICC indicates T=0 parity error. This feature can be enabled/disabled by firmware. Deletion of last byte received if ICC indicates T=0 parity error. This feature can be enabled/disabled by firmware. CRC/LRC generation and checking. CRC/LRC is automatically inserted into T=1 data stream by the hardware. This feature can be enabled/disabled by firmware. Support baud rates: 115200, 57600, 38400, 28800, 19200, 14400, 9600 under firmware control (assuming 12MHz crystal) with various F/D settings. Firmware manages F/D. All F/D combinations are supported in which F/D is directly divisible by 31 or 32 (i.e. F/D is a multiple of either 31 or 32). Flexible ETU clock generation and control. Detection of convention (direct or indirect) character TS. This affects both polarity and order of bits in byte. Convention can be overridden by firmware. Supports WTX Timeout with an expanded Wait Time Counter (28 bits). A Bypass Mode is provided to bypass the hardware UART in order for the software to emulate the UART (for non-standard operating modes). In such a case, the I/O line value is reflected in SFR SCCtl or SCECtl respectively for the built-in or external interfaces. This mode is appropriate for some synchronous and non T=0 / T=1 cards. The single integrated smart card UART is capable of supporting T=0 and T=1 cards in hardware therefore offloading the bit manipulation tasks from the firmware. The embedded firmware instructs the hardware which smart card it should communicate with at any point in time. Firmware reconfigures the UART as required when switching between smart cards. When the 73S1210F has transmitted a message with an expected response, the firmware should not switch the UART to another smart card until the first smart card has responded. If the smart card responds while another smart card is selected, that first smart card's response will be ignored. Rev. 1.4 71 73S1210F Data Sheet 1.7.15.2 DS_1210F_001 Answer to Reset Processing A card insertion event generates an interrupt to the firmware, which is then responsible for the configuration of the electrical interface, the UART and activation of the card. The activation sequencer goes through the power up sequence as defined in the ISO 7816-3 specification. An asynchronous activation timing diagram is shown in Figure 16. After the card reset is de-asserted, the firmware instructs the hardware to look for a TS byte that begins the ATR response. If a response is not provided within the pre-programmed timeout period, an interrupt is generated and the firmware can then take appropriate action, including instructing the 73S1210F to begin a deactivation sequence. Once commanded, the deactivation sequencer goes through the power down sequence as defined in the ISO 7816-3 specification. If an ATR response is received, the hardware looks for a TS byte that determines direct/inverse convention. The hardware handles the indirect convention conversion such that the embedded firmware only receives direct convention. This feature can be disabled by firmware within SByteCtl register. Parity checking and break generation is performed on the TS byte unless disabled by firmware. If during the card session, a card removal, over-current or other error event is detected, the hardware will automatically perform the deactivation sequence and then generate an interrupt to the firmware. The firmware can then perform any other error handling required for proper system operation. Smart card RST, I/O and CLK, C4, C8 shall be low before the end of the deactivation sequence. Figure 17 shows the timing for a deactivation sequence. SELSC bits VCCSEL bits VCC VCCOK bit t4 RSTCRD bit See Note RST CLK ATR starts IO t1 t2 t3 t4 t5 tto t1: SELSC.1 bit set (selects internal ICC interface) and a non-zero value in VCCSEL bits (calling for a value of Vcc of 1.8, 3.0, or 5.0 volts) will begin the activation sequence. t1 is the time for Vcc to rise to acceptable level, declared as Vcc OK (bit VCCOK gets set). This time depends on filter capacitor value and card Icc load. tto: The time allowed for Vcc to rise to Vcc OK status after setting of the VCCSEL bits. This time is generated by the VCCTMR counter. If Vcc OK is not set, (bit VCCOK) at this time, a deactivation will be initiated. VCCSEL bits are not automatically cleared. The firmware must clear the VCCSEL bits before starting a new activation. t2: Time from VccTmr timeout and VCC OK to IO reception (high), typically 2-3 CLK cycles if RDYST = 0. If RDYST = 1, t2 starts when VCCOK = 1. t3: Time from IO = high to CLK start, typically 2-3 CLK cycles. t4: Time allowed for start of CLK to de-assertion of RST. Programmable by the RLength register. t5: Time allowed for ATR timeout, set by the STSTO register. Note: If the RSTCRD bit is set, RST is asserted (low). Upon clearing RSTCRD bit, RST will be de-asserted after t4. 72 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Figure 16: Asynchronous Activation Sequence Timing Firmware sets VCCSEL to 00 t5 t5 delay or Card Event IO RST CLK CMDVCCnB VCC t3 t1 t2 t4 t1: Time after either a "card event" occurs or firmware sets the VCCSela and VCCSelb bits to 0 (see t5, VCCOff_tmr) occurs until RST is asserted low. t2: Time after RST goes low until CLK stops. t3: Time after CLK stops until IO goes low. t4: Time after IO goes low until VCC is powered down. t5: Delayed VCC off time (in ETUs per VCCOff_tmr bits). Only in effect due to firmware deactivation. Figure 17: Deactivation Sequence 1.7.15.3 Data Reception/Transmission When a 12Mhz crystal is used, the smart card UART will generate a 3.69Mhz (default) clock to both smart card interfaces. This will allow approximately 9600bps (1/ETU) communication during ATR (ISO 7816 default). As part of the PPS negotiation between the smart card and the reader, the firmware may determine that the smart card parameters F & D may be changed. After this negotiation, the firmware may change the ETU by writing to the SFR FDReg to adjust the ETU and CLK. The firmware may also change the smart card clock frequency by writing to the SFR SCCLK (SCECLK for external interface). Independent clock frequency control is provided to each smart card interface. Clock stop high or Clock stop low is supported in asynchronous mode. Figure 18 shows the ETU and CLK control circuits. The firmware determines when clock stop is supported by the smart card and when it is appropriate to go into that mode (and when to come out of it). The smart card UART is clocked by the same clock that is provided to the selected smart card. The transition between smart card clocks is handled in hardware to eliminate any glitches for the UART during switchover. The external smart card clock is not affected when switching the UART to communicate with the internal smart card. Rev. 1.4 73 73S1210F Data Sheet DS_1210F_001 FDReg(3:0) FDReg(7:4) FI Decoder F/D Register Pre-Scaler 6 bits ETUCLK 7.38M EDGE ETU Divider 12 bits 1/13 9926 CENTER 1/744 SCSel(3:2) SYNC SCCLK(5:0) MSCLK 7.38M SCSCLK(5:0) DIV by 2 3.69M CLK MCLK = 96MHz Pre-Scaler 6 bits PLL MSCLKE 7.38M 1/13 DIV by 2 3.69M SCLK Defaults in Italics Figure 18: Smart Card CLK and ETU Generation There are two, two-byte FIFOs that are used to buffer transmit and receive data. During a T=0 processing, if a parity error is detected by the 73S1210F during message reception, an error signal (BREAK) will be generated to the smart card. The byte received will be discarded and the firmware notified of the error. Break generation and receive byte dropping can be disabled under firmware control. During the transmission of a byte, if an error signal (BREAK) is detected, the last byte is retransmitted again and the firmware notified. Retransmission can be disabled by firmware. When a correct byte is received, an interrupt is generated to the firmware, which then reads the byte from the receive FIFO. Receive overruns are detected by the hardware and reported via an interrupt. During transmission of a message, the firmware will write bytes into the transmit FIFO. The hardware will send them to the smart card. When the last byte of a message has been written, the firmware will need to set the LASTTX bit in the STXCtl SFR. This will cause the hardware to insert the CRC/LRC if in a T=1 protocol mode. CRC/LRC generation/checking is only provided during T=1 processing. Firmware will need to instruct the smart function to go into receive mode after this last transmit data byte if it expects a response from the smart card. At the end of the smart card response, the firmware will put the interface back into transmit mode if appropriate. The hardware can check for the following card-related timeouts: * * * Character Waiting Time (CWT) Block Waiting Time (BWT) Initial Waiting Time (IWT) The firmware will load the Wait Time with the appropriate value for the operating mode at the appropriate time. Figure 19 shows the guard, block, wait and ATR time definitions. If a timeout occurs, an interrupt will be generated and the firmware can take appropriate recovery steps. Support is provided for adding additional guard times between characters using the Extra Guard Time register (EGT), and between the last byte received by the 73S1210F and the first byte transmitted by the 73S1210F using the Block Guard Time register (BGT). Other than the protocol checks described above, the firmware is responsible for all protocol checking and error recovery. 74 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet T = 0 Mode > EGT CHAR 1 CHAR 2 < WWT WWT is set by the value in the BWT registers. T = 1 Mode TRANSMISSION RECEPTION (By seting Last_TXByte and TX/RXB=0 during CHAR N, RX mode will start after last TX byte) BLOCK1 CHAR 1 CHAR 2 CHAR N BGT(4:0) BLOCK2 CHAR N+1 CHAR N+2 CHAR N+3 TX > BWT EGT < CWT ATR Timing Parameters CHAR 1 CHAR 2 CHAR N IO TSTO(7:0) ATRTO(15:0) RST IWT(15:0) RLen(7:0) VCC_OK Figure 19: Guard, Block, Wait and ATR Time Definitions 1.7.15.4 Bypass Mode It is possible to bypass the smart card UART in order for the firmware to support non-T=0/T=1 smart cards. This is called Bypass mode. In this mode the embedded firmware will communicate directly with the selected smart card and drive I/O during transmit and read I/O during receive in order to communicate with the smart card. In this mode, ATR processing is under firmware control. The firmware must sequence the interface signals as required. Firmware must perform TS processing, parity checking, break generation and CRC/LRC calculation (if required). 1.7.15.5 Synchronous Operation Mode The 73S1210F supports synchronous operation. When sync mode is selected for either interface, the CLK signal is generated by the ETU counter. The values in c, SCCLK, and SCECLK must be set to obtain the desired sync CLK rate. There is only one ETU counter and therefore, in sync mode, the interface must be selected to obtain a smart card clock signal. In sync mode, input data is sampled on the rise of CLK, and output data is changed on the fall of CLK. Rev. 1.4 75 73S1210F Data Sheet DS_1210F_001 Special Notes Regarding Synchronous Mode Operation When the SCISYN or SCESNC bits (SPrtcol, bit 7, bit 5, respectively) are set, the selected smart card interface operates in synchronous mode and there are changes in the definition and behavior of pertinent register bits and associated circuitry. The following requirements are to be noted: 1. The source for the smart card clock (CLK or SCLK) is the ETU counter. Only the actively selected interface can have a running synchronous clock. In contrast, an unselected interface may have a running clock in the asynchronous mode of operation. 2. The control bits CLKLVL, SCLKLVL, CLKOFF, and SCLKOFF are functional in synchronous mode. When the CLKOFF bit is set, it will not truncate either the logic low or logic high period when the (stop at) level is of opposite polarity. The CLK/SCLK signal will complete a correct logic low or logic high duty cycle before stopping at the selected level. The CLK "start" is a result of the falling edge of the CLKOFF bit. Setting clock to run when it is stopped low will result in a half period of low before going high. Setting clock to run when it is stopped high will result in the clock going low immediately and then running at the selected rate with 50% duty cycle (within the limitations of the ETU divisor value). 3. The Rlen(7:0) is configured to count the falling edges of the ETU clock (CLK or SCLK) after it has been loaded with a value from 1 to 255. A value of 0 disables the counting function and RLen functions such as I/O source selection (I/O signal bypasses the FIFOs and is controlled by the SCCLK/SCECLK SFRs). When the RLen counter reaches the "max" (loaded) value, it sets the WAITTO interrupt (SCInt, bit 7), which is maskable via WTOIEN (SCIE, bit 7). It must be reloaded in order to start the counting/clocking process again. This allows the processor to select the number of CLK cycles and hence, the number of bits to be read or written to/from the card. 4. The FIFO is not clocked by the first CLK (falling) edge resulting from a CLKOFF de-assertion (a clock start event) when the CLK was stopped in the high state and RLen has been loaded but not yet clocked. 5. The state of the pin IO or SIO is sampled on the rising edge of CLK/SCLK and stored in bit 5 of the SCCtl/SCECtl register. 6. When Rlen = max or 0 and I2CMODE= 1 (STXCtl, b7), the IO or SIO signal is directly controlled by the data and direction bits in the respective SCCtl and SCECtl register. The state of the data in the TX FIFO is bypassed. 7. In the SPrtcol register, bit 6 (MODE9/8B) becomes active. When set, the RXData FIFO will read nine-bit words with the state of the ninth bit being readable in SRXCtl, bit 7 (B9DAT). The RXDAV interrupt will occur when the ninth bit has been clocked in (rising edge of CLK or SCLK). 8. Care must be taken to clear the RX and TX FIFOs at the start of any transaction. The user shall read the RX FIFO until it indicates empty status. Reading the TX FIFO twice will reset the input byte pointer and the next write to the TX FIFO will load the byte to the "first out" position. Note that the bit pointer (serializer/deserializer) is reset to bit 0 on any change of the TX/RXD bit. Special bits that are only active for sync mode include: SRXCtl, b7 "BIT9DAT", SPrtcol, b6 "MODE9/8B", STXCtl, b7 "I2CMODE", and the definition of SCInt, b7, which was "WAITTO", becomes RLenINT interrupt, and SCIE, b7, which was "WTOIEN", becomes RLenIEN. 76 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet VCCSEL bits VCC VCCOK RSTCRD RST t3 CLK IO t4 t1 t2 tto t1: The time from setting VCCSEL bits until VCCOK = 1. tto: The time from setting VCCSEL bits until VCCTMR times out. At t1 (if RDYST = 1) or tto (if RDYST = 0), activation starts. It is suggested to have RDYST = 0 and use the VCCTMR interrupt to let MPU know when sequence is starting. t2: time from start of activation (no external indication) until IO goes into reception mode (= 1). This is approximately 4 SCCLK (or SCECLK) clock cycles. t3: minimum one half of ETU period. t4: ETU period. Note that in Sync mode, IO as input is sampled on the rising edge of CLK. IO changes on the falling edge of CLK, either from the card or from the 73S1210F. The RST signal to the card is directly controlled by the RSTCRD bit (non-inverted) via the MPU and is shown as an example of a possible RST pattern. Figure 20: Synchronous Activation IO reception on 5 2 RST CLK CLKOFF 1 CLKLVL RLength Count RLenght = 1 7 Count MAX 4 3 Rlength Interrupt 6 TX/RXB Mode bit (TX = '1') t1 1. Clear CLKOFF after Card is in reception mode. 2. Set RST bit. 3. Interrupt is generated when Rlength counter is MAX. 4. Read and clear Interrupt. 5. Clear RST bit. 6. Toggle TX/RXB to reset bit counter. 7. Reload RLength Counter. t1. CLK wll start at least 1/2 ETU after CLKOFF is set low when CLKLVL = 0 Figure 21: Example of Sync Mode Operation: Generating/Reading ATR Signals Rev. 1.4 77 73S1210F Data Sheet DS_1210F_001 START Bit CLK IO Data from Card -end of ATR RLength Count MAX RLength Count - was set for length of ATR RLen=0 5 Rlen=1 2 1 RLength Interrupt Data from TX FIFO 6 CLK Stop 3 CLK Stop Level 7 IO Bit IODir Bit 6 TX/RX Mode Bit TX = '1' 4 1. Interrupt generated when Rlength counter is MAX. 2. Read and clear Interrupt. 3. Set CLK Stop and CLK Stop level high in Interrupt routine. 4. Set TX/RX Bit to TX mode. 5. Reload Rlength Counter. 6. Set IO Bit low and IODir = Output. Since Rlen=(MAX or 0) and TX/RX =1, IO pin is controlled by IO bit. 7. Clear CLK Stop and CLK Stop level. Note: Data in TX fifo should not be Empty here. Synchronous Clock Start/Stop Mode style Start bit procedure. This procedure should be used to generate the start bit insertion in Synchronous mode for Synchronous Clock Start/Stop Mode protocol. Figure 22: Creation of Synchronous Clock Start/Stop Mode Start Bit in Sync Mode CLK IO I2CMode = 1: Data to/from Card I2CMode = 0: Data from TX fifo I2CMode = 1:ACK Bit (to/from card) I2CMode = 0: Data from TX fifo 6 RLength Count MAX RLength Count (Rlength = 9) STOP Bit 1 2 RLength Interrupt CLK Stop 8 3 CLK Stop Level 7 IO Bit 4 IODir Bit TX/RX Mode Bit TX = '1' TX/RX mode 5 1. Interrupt generated when Rlength counter is MAX. 2. Read and clear Interrupt. 3. Set CLK Stop and CLK Stop level high. 4. Set IO Bit low and IODir = Output. 5. Set TX/RX Bit to TX mode. 6. Reload Rlength Counter. 7. Set IO Bit High and IODir = Output. 8. Clear CLK Stop and CLK Stop level. Note: Data in TX fifo should not be Empty here. Synchronous Clock Start/Stop Mode Stop bit procedure. This procedure should be used to generate the Stop bit in Synchronous Mode. SYCKST is bit 7 of STXCTL register. Figure 23: Creation of Synchronous Clock Start/Stop Mode Stop Bit in Sync Mode 78 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet CLK IO RLength Count RLength = 9 Data from Card (Bit 8) Data from Card (Bit 1) Protection Bit (Bit 9) RLength Count MAX Rlen=9 Rlen=8 Rlen=0 Rlen =1 RLength Interrupt RX FIFO (Data from Card is ready for CPU read) RX data Protection Bit Data (Bit 9) Protection Bit is ready for CPU read TX/RX Mode Bit TX = '1' 1._ Interrupt generated when Rlength counter is Max 2._ Read and clear Interrupt 3._ Reload RLength counter Receive data in 9 bit mode CLK RLength Count RLength = 9 RLength Count MAX Rlen=9 Rlen=8 RLength Interrupt CLK Stop CLK Stop Level = 0 1._ Interrupt generated when Rlength counter is Max 2._Stop CLK after the last byte and protection bit Stop CLK after receiving the last byte and protection bit. Figure 24: Operation of 9-bit Mode in Sync Mode Synchronous card operation is broken down into three primary types. These are commonly referred to as 2-wire, 3-wire and I2C synchronous cards. Each card type requires different control and timing and therefore requires different algorithms to access. Teridian has created an application note to provide detailed algorithms for each card type. Refer to the application note titled "73S12xxF Synchronous Card Design Application Note". Rev. 1.4 79 73S1210F Data Sheet 1.7.15.6 DS_1210F_001 Smart Card SFRs Smart Card Select Register (SCSel): 0xFE00 0x00 The Smart Card Select register is used to determine which smart card interface is using the ISO UART. The internal Smart Card has integrated 7816-3 compliant sequencer circuitry to drive an external smart card interface. The external smart card interface relies on 73S8010 parts to generate the ISO 7816-3 compatible signals and sequences. Multiple 73S8010 devices can be connected to the external smart card interface. Table 72: The SCSel Register MSB LSB - - - - SELSC.1 SELSC.0 BYPASS - Bit Symbol SCSel.7 - SCSel.6 - SCSel.5 - SCSel.4 - SCSel.3 SELSC.1 Select Smart Card Interface - These bits select the interface that is using the IS0 UART. These bits do not activate the interface. Activation is performed by the VccCtl register. SCSel.2 SELSC.0 00 = No smart card interface selected. 01 = External Smart Card Interface selected (using SCLK, SIO). 1X = Internal Smart Card Interface selected. SCSel.1 BYPASS 1 = Enabled, 0 = Disabled. When enabled, ISO UART is bypassed and the I/O line is controlled via the SCCtl and SCECtl registers. SCSel.0 - 80 Function Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Smart Card Interrupt Register (SCInt): 0xFE01 0x00 When the smart card interrupt is asserted, the firmware can read this register to determine the actual cause of the interrupt. The bits are cleared when this register is read. Each interrupt can be disabled by the Smart Card Interrupt Enable register. Error processing must be handled by the firmware. This register relates to the interface that is active - see the SCSel register (above). Table 73: The SCInt Register MSB LSB WAITTO CRDEVT VCCTMRI Bit Symbol Function WAITTO Wait Timeout - An ATR or card wait timeout has occurred. In sync mode, this interrupt is asserted when the RLen counter (it advances on falling edges of CLK/ETU) reaches the loaded (max) value. This bit is cleared when the SCInt register is read. When running in Synchronous Clock Stop Mode, this bit becomes RLenINT interrupt (set when the Rlen counter reaches the terminal count). SCInt.6 CRDEVT Card Event - A card event is signaled via pin DETCARD either when the Card was inserted or removed (read the CRDCtl register to determine card presence) or there was a fault condition in the interface circuitry. This bit is functional even if the smart card logic clock is disabled and when the PWRDN bit is set. This bit is cleared when the SCInt register is read. SCInt.5 VCCTMRI VCC Timer - This bit is set when the VCCTMR times out. This bit is cleared when the SCInt register is read. SCInt.7 RXDAV TXEVT TXSENT TXERR RXERR SCInt.4 RXDAV Rx Data Available - Data was received from the smart card because the Rx FIFO is not empty. In bypass mode, this interrupt is generated on a falling edge of the smart card I/O line. After receiving this interrupt in bypass mode, firmware should disable it until the firmware has received the entire byte and is waiting for the next start delimiter. This bit is cleared when there is no RX data available in the RX FIFO. SCInt.3 TXEVNT TX Event - Set whenever the TXEMTY or TXFULL bits are set in the SRXCtl SFR. This bit is cleared when the STXCtl register is read. TXSENT TX Sent - Set whenever the ISO UART has successfully transmitted a byte to the smart card. Also set when a CRC/LRC byte is sent in T=1 mode. Will not be set in T=0 when a break is detected at the end of a byte (when break detection is enabled). This bit is cleared when the SCInt register is read. TXERR TX Error - An error was detected during the transmission of data to the smart card as indicated by either BREAKD or TXUNDR bit being set in the STXCtl SFR. Additional information can be found in that register description. This bit is cleared when the STXCtl register is read. RXERR RX Error - An error was detected during the reception of data from the smart card. Additional information can be found in the SRXCtl register. This interrupt will be asserted for RXOVRR, or RX Parity error events. This bit is cleared when the SRXCtl register is read. SCInt.2 SCInt.1 SCInt.0 Rev. 1.4 81 73S1210F Data Sheet DS_1210F_001 Smart Card Interrupt Enable Register (SCIE): 0xFE02 0x00 When set to 1, the respective condition can cause a smart card interrupt. When set to a 0, the respective condition cannot cause an interrupt. When disabled, the respective bit in the Smart Card Interrupt register can still be set, but it will not interrupt the MPU. Table 74: The SCIE Register MSB LSB WTOIEN CDEVEN VTMREN RXDAEN TXEVEN 82 TXSNTEN TXEREN RXEREN Bit Symbol Function SCIE.7 WTOIEN Wait Timeout Interrupt Enable - Enable for ATR or Wait Timeout Interrupt. In sync mode, function is RLIEN (RLen = max.) interrupt enable. SCIE.6 CDEVEN Card Event Interrupt Enable. SCIE.5 VTMREN VCC Timer Interrupt Enable. SCIE.4 RXDAEN Rx Data Available Interrupt Enable. SCIE.3 TXEVEN TX Event Interrupt Enable. SCIE.2 TXSNTEN TX Sent Interrupt Enable. SCIE.1 TXEREN TX Error Interrupt Enable. SCIE.0 RXEREN RX Error Interrupt Enable. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Smart Card VCC Control/Status Register (VccCtl): 0xFE03 0x00 This register is used to control the power up and power down of the integrated smart card interface. It is used to determine whether to apply 5V, 3V, or 1.8 to the smart card. Perform the voltage selection with one write operation, setting both VCCSEL.1 and VCCSEL.0 bits simultaneously. The VDDFLT bit (if enabled) will provide an emergency deactivation of the internal smart card slot. See the VDD Fault Detect Function section for more detail. Table 75: The VccCtl Register MSB LSB VCCSEL.1 VCCSEL.0 Bit VDDFLT RDYST Symbol VCCOK - - SCPWRDN Function Setting non-zero value for bits 7,6 will begin activation sequence with target Vcc as given below: VccCtl.7 VCCSEL.1 State 1 2 3 4 VccCtl.6 VCCSEL.0 A card event or VCCOK going low will initiate a deactivation sequence. When the deactivation sequence for RST, CLK and I/O is complete, VCC will be turned off. When this type of deactivation occurs, the bits must be reset before initiating another activation. VccCtl.5 VDDFLT When there is a VDD Fault event, this bit will be set = 0. This causes VCCSEL.1 and VCCSEL.0 bits to be immediately set = 0 to begin deactivation. VccCtl.4 RDYST If this bit is set = 1, the activation sequence will start when bit VCCOK is set = 1. If not set, the deactivation sequence shall start when the VCCTMR times out. VccCtl.3 VCCOK (Read only). Indicates that VCC output voltage is stable. VccCtl.2 - VccCtl.1 - VCCSEL.1 0 0 1 1 VCCSEL.0 0 1 0 1 VCC 0V 1.8V 3.0V 5V This bit controls the power-off mode of the 73S1210F circuit. VccCtl.0 Rev. 1.4 1 = power off, 0 = normal operation. When in power down mode, SCPWRDN VDD = 0V. VDD can only be turned on by pressing the ON/OFF switch or by application of 5V to VBUS. If VBUS power is available and SCPWRDN bit is set, it has no effect until VBUS is removed and VDD will shut off. 83 73S1210F Data Sheet DS_1210F_001 VCC Stable Timer Register (VccTmr): 0xFE04 0x0F A programmable timer is provided to set the time from activation start (setting the VCCSEL.1 and VCCSEL.0 bits to non-zero) to when VCC_OK is evaluated. VCC_OK must be true at the end of this timers programmed interval (tto in Figure 16) in order for the activation sequence to continue. If VCC_OK is not true and the end of the interval (tto), the Card Event interrupt will be set, and a deactivation sequence shall begin including clearing of the VCCSEL bits. Table 76: The VccTmr Register MSB LSB OFFTMR.3 OFFTMR.2 OFFTMR.1 OFFTMR.0 VCCTMR.3 VCCTMR.2 VCCTMR.1 VCCTMR.0 Bit Symbol Function VccTmr.7 OFFTMR.3 VccTmr.6 OFFTMR.2 VccTmr.5 OFFTMR.1 VccTmr.4 OFFTMR.0 VCC Off Timer - The bits set the delay (in number of ETUs) for deactivation after the VCCSEL.1 and VCC SEL.0 have been set to 0. The time value is a count of the 32768Hz clock and is given by tto = OFFTMR(7:4) * 30.5s. This delay does not affect emergency deactivations due to VDD Fault or card events. A value of 0000 results in no additional delay. VccTmr.3 VCCTMR.3 VCC Timer - VCCOK must be true at the time set by the value in VCCTMR.2 these bits in order for the activation sequence to continue. If not, the VCCSEL bits will be cleared. The time value is a count of the VCCTMR.1 32768Hz clock and is given by tto = VCCTMR(3:0) * 30.5s. A value of 0000 results in no timeout, not zero time, and activation VCCTMR.0 requires that RDYST is set and RDY goes high. VccTmr.2 VccTmr.1 VccTmr.0 84 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Card Status/Control Register (CRDCtl): 0xFE05 0x00 This register is used to configure the card detect pin (DETCARD) and monitor card detect status. This register must be written to properly configure Debounce, Detect_Polarity (= 0 or = 1), and the pullup/down enable before setting CDETEN. The card detect logic is functional even without smart card logic clock. When the PWRDN bit is set = 1, no debounce is provided but card presence is operable. Table 77: The CRDCtl Register MSB LSB DEBOUN CDETEN Bit - - DETPOL PUENB PDEN CARDIN Symbol Function CRDCtl.7 DEBOUN Debounce - When set = 1, this will enable hardware debounce of the card detect pin. The debounce function shall wait for 64ms of stable card detect assertion before setting the CARDIN bit. This counter/timer uses the keypad clock as a source of 1kHz signal. De-assertion of the CARDIN bit is immediate upon de-assertion of the card detect pin(s). CRDCtl.6 CDETEN Card Detect Enable - When set = 1, activates card detection input. Default upon power-on reset is 0. CRDCtl.5 - CRDCtl.4 - CRDCtl.3 DETPOL Detect Polarity - When set = 1, the DETCARD pin shall interpret a logic 1 as card present. CRDCtl.2 PUENB Enable pull-up current on DETCARD pin (active low). CRDCtl.1 PDEN CRDCtl.0 Rev. 1.4 CARDIN Enable pull-down current on DETCARD pin. Card Inserted - (Read only). 1 = card inserted, 0 = card not inserted. A change in the value of this bit is a "card event." A read of this bit indicates whether smart card is inserted or not inserted in conjunction with the DETPOL setting. 85 73S1210F Data Sheet DS_1210F_001 TX Control/Status Register (STXCtl): 0xFE06 0x00 This register is used to control transmission of data to the smart card. Some control and some status bits are in this register. Table 78: The STXCtl Register MSB LSB I2CMODE Bit STXCtl.7 - Symbol TXFULL TXEMTY TXUNDR LASTTX TX/RXB BREAKD Function I2C Mode - When in sync mode and this bit is set, and when the RLen count value = max or 0, the source of the smart card data for IO pin (or SIO pin) will I2CMODE be connected to the IO bit in SCCtl (or SCECtl) register rather than the TX FIFO. See the description for the Protocol Mode Register for more detail. STXCtl.6 - STXCtl.5 TXFULL TX FIFO is full. Additional writes may corrupt the contents of the FIFO. This bit it will remain set as long as the TX FIFO is full. Generates a TX_Event interrupt upon going full. TXEMTY 1 = TX FIFO is empty, 0 = TX FIFO is not empty. If there is data in the TX FIFO, the circuit will transmit it to the smart card if in transmit mode. In T=1 mode, if the LASTTX bit is set and the hardware is configured to transmit the CRC/LRC, the TXEMTY will not be set until the CRC/LRC is transmitted. In T=0, if the LASTTX bit is set, TXEMTY will be set after the last word has been successfully transmitted to the smart card. Generates a TXEVNT interrupt upon going empty. TXUNDR TX Underrrun - (Read only) Asserted when a transmit under-run condition has occurred. An under-run condition is defined as an empty TX FIFO when the last data word has been successfully transmitted to the smart card and the LASTTX bit was not set. No special processing is performed by the hardware if this condition occurs. Cleared when read by firmware. This bit generates a TXERR interrupt. LASTTX Last TX Byte - Set by firmware (in both T=0 and T=1) when the last byte in the current message has been written into the transmit FIFO. In T=1 mode, the CRC/LRC will be appended to the message. Should be set after the last byte has been written into the transmit FIFO. Should be cleared by firmware before writing first byte of next message into the transmit FIFO. Used in T=0 to determine when to set TXEMTY. STXCtl.1 TX/RXB 1 = Transmit mode, 0 = Receive mode. Configures the hardware to be receiving from or transmitting to the smart card. Determines which counters should be enabled. This bit should be set to receive mode prior to switching to another interface. Setting and resetting this bit shall initialize the CRC logic. If LASTTX is set, this bit can be reset to RX mode and UART logic will automatically change mode to RX when TX operation is completed (TX_Empty = 1). STXCtl.0 BREAKD Break Detected - (Read only) 1 = A break has been detected on the I/O line indicating that the smart card detected a parity error. Cleared when read. This bit generates a TXERR interrupt. STXCtl.4 STXCtl.3 STXCtl.2 86 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet STX Data Register (STXData): 0xFE07 0x00 Table 79: The STXData Register MSB LSB STXDAT.7 STXDAT.6 STXDAT.5 STXDAT.4 STXDAT.3 Bit STXDAT.2 STXDAT.1 STXDAT.0 Function STXData.7 STXData.6 STXData.5 STXData.4 STXData.3 STXData.2 Data to be transmitted to smart card. Gets stored in the TX FIFO and then extracted by the hardware and sent to the selected smart card. When the MPU reads this register, the byte pointer is changed to effectively "read out" the data. Thus, two reads will always result in an "empty" FIFO condition. The contents of the FIFO registers are not cleared, but will be overwritten by writes. STXData.1 STXData.0 SRX Control/Status Register (SRXCtl): 0xFE08 0x00 This register is used to monitor reception of data from the smart card. Table 80: The SRXCtl Register MSB LSB BIT9DAT - Bit Symbol SRXCtl.7 BIT9DAT SRXCtl.6 - LASTRX CRCERR RXFULL RXEMTY RXOVRR PARITYE Function Bit 9 Data - When in sync mode and with MODE9/8B set, this bit will contain the data on IO (or SIO) pin that was sampled on the ninth CLK (or SCLK) rising edge. This is used to read data in synchronous 9-bit formats. SRXCtl.5 LASTRX Last RX Byte - User sets this bit during the reception of the last byte. When byte is received and this bit is set, logic checks CRC to match 0x1D0F (T=1 mode) or LRC to match 00h (T=1 mode), otherwise a CRC or LRC error is asserted. SRXCtl.4 CRCERR (Read only) 1 = CRC (or LRC) error has been detected. SRXCtl.3 RXFULL (Read only) RX FIFO is full. Status bit to indicate RX FIFO is full. SRXCtl.2 RXEMTY (Read only) RX FIFO is empty. This is only a status bit and does not generate an RX interrupt. SRXCtl.1 RXOVRR RX Overrun - (Read Only) Asserted when a receive-over-run condition has occurred. An over-run is defined as a byte was received from the smart card when the RX FIFO was full. Invalid data may be in the receive FIFO. Firmware should take appropriate action. Cleared when read. Additional writes to the RX FIFO are discarded when a RXOVRR occurs until the overrun condition is cleared. Will generate an RXERR interrupt. SRXCtl.0 PARITYE Parity Error - (Read only) 1 = The logic detected a parity error on incoming data from the smart card. Cleared when read. Will generate an RXERR interrupt. Rev. 1.4 87 73S1210F Data Sheet DS_1210F_001 SRX Data Register (SRXData): 0xFE09 0x00 Table 81: The SRXData Register MSB LSB SRXDAT.7 SRXDAT.6 SRXDAT.5 SRXDAT.4 SRXDAT.3 SRXDAT.2 SRXDAT.1 SRXDAT.0 Bit Function SRXData.7 SRXData.6 SRXData.5 SRXData.4 SRXData.3 (Read only) Data received from the smart card. Data received from the smart card gets stored in a FIFO that is read by the firmware. SRXData.2 SRXData.1 SRXData.0 88 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Smart Card Control Register (SCCtl): 0xFE0A 0x21 This register is used to monitor reception of data from the smart card. Table 82: The SCCtl Register MSB LSB RSTCRD Bit - IO IOD C8 C4 CLKLVL CLKOFF Symbol Function SCCtl.7 RSTCRD 1 = Asserts the RST (set RST = 0) to the smart card interface, 0 = De-assert the RST (set RST = 1) to the smart card interface. Can be used to extend RST to the smart card. Refer to RLength register description. This bit is operational in all modes and can be used to extend RST during activation or perform a "Warm Reset" as required. In auto-sequence mode, this bit should be set = 0 to allow the sequencer to de-assert RST per the RLength parameters. In sync mode (see the SPrtcol register) the sense of this bit is non-inverted, if set = 1, RST = 1, if set = 0, RST = 0. Rlen has no effect on Reset in sync mode. SCCtl.6 - Smart Card I/O. Read is state of I/O signal (Caution, this signal is not synchronized to the MPU clock). In Bypass mode, write value is state of signal on I/O. In sync mode, this bit will contain the value of I/O pin on the latest rising edge of CLK. SCCtl.5 IO SCCtl.4 IOD Smart Card I/O Direction control Bypass mode or sync mode. 1 = input (default), 0 = output. C8 Smart Card C8. When C8 is an output, the value written to this bit will appear on the C8 line. The value read when C8 is an output is the value stored in the register. When C8 is an input, the value read is the value on the C8 pin (Caution, this signal is not synchronized to the MPU clock). When C8 is an input, the value written will be stored in the register but not presented to the C8 pin. SCCtl.2 C4 Smart Card C4. When C4 is an output, the value written to this bit will appear on the C4 line. The value read when C4 is an output is the value stored in the register. When C4 is an input, the value read is the value on the C4 pin (Caution, this signal is not synchronized to the MPU clock). When C4 is an input, the value written will be stored in the register but not presented to the C4 pin. SCCtl.1 CLKLVL 1 = High, 0 = Low. If CLKOFF is set = 1, the CLK to smart card will be at the logic level indicated by this bit. If in bypass mode, this bit directly controls the state of CLK. SCCtl.0 CLKOFF 0 = CLK is enabled. 1 = CLK is not enabled. When asserted, the CLK will stop at the level selected by CLKLVL. This bit has no effect if in bypass mode. SCCtl.3 Rev. 1.4 89 73S1210F Data Sheet DS_1210F_001 External Smart Card Control Register (SCECtl): 0xFE0B 0x00 This register is used to directly set and sample signals of External Smart Card interface. There are three modes of asynchronous operation, an "automatic sequence" mode, and bypass mode. Clock stop per the ISO 7816-3 interface is also supported but firmware must handle the protocol for SIO and SCLK for I2C clock stop and start. Control for Reset (to make RST signal), activation control, voltage select, etc. should be handled via the I2C interface when using external 73S8010 devices. USR(n) pins shall be used for C4, C8 functions if necessary. Table 83: The SCECtl Register MSB LSB - - Bit Symbol SCECtl.7 - SCECtl.6 - SIO SIOD - - SCLKLVL SCLKOFF Function SCECtl.5 SIO External Smart Card I/O. Bit when read indicates state of pin SIO for SIOD = 1 (Caution, this signal is not synchronized to the MPU clock), when written, sets the state of pin SIO for SIOD = 0. Ignored if not in bypass or sync modes. In sync mode, this bit will contain the value of IO pin on the latest rising edge of SCLK. SCECtl.4 SIOD 1 = input, 0 = output. External Smart Card I/O Direction control. Ignored if not in bypass or sync modes. SCECtl.3 - SCECtl.2 - SCECtl.1 SCLKLVL Sets the state of SCLK when disabled by SCLKOFF bit. If in bypass mode, this bit directly controls the state of SCLK. SCECtl.0 SCLKOFF 0 = SCLK enabled, 1 = SCLK disabled. When disabled, SCLK level is determined by SCLKLVL. This bit has no effect if in bypass mode. 90 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet C4/C8 Data Direction Register (SCDIR): 0xFE0C 0x00 This register determines the direction of the internal interface C4/C8 lines. After reset, all signals are tri-stated. Table 84: The SCDIR Register MSB LSB - - - - C8D C4D Bit Symbol SCDIR.7 - SCDIR.6 - SCDIR.5 - SCDIR.4 - SCDIR.3 C8D 1 = input, 0 = output. Smart Card C8 direction. SCDIR.2 C4D 1 = input, 0 = output. Smart Card C4 direction. SCDIR.1 - SCDIR.0 - Rev. 1.4 - - Function 91 73S1210F Data Sheet DS_1210F_001 Protocol Mode Register (SPrtcol): 0xFE0D 0x03 This register determines the protocol to be use when communicating with the selected smart card. This register should be updated as required when switching between smart card interfaces. Table 85: The SPrtcol Register MSB LSB SCISYN Bit MOD9/8B SCESYN Symbol 0 TMODE CRCEN CRCMS RCVATR Function Smart Card Internal Synchronous mode - Configures internal smart card interface for synchronous mode. This mode routes the internal interface buffers for RST, IO, C4, C8 to the SCCtl register bits for direct firmware control. CLK is generated by the ETU counter. SPrtcol.7 SCISYN SPrtcol.6 MOD9/8B Synchronous 8/9 bit mode select - For sync mode, in protocols with 9-bit words, set this bit. The first eight bits read go into the RX FIFO and the ninth bit read will be stored in the IO (or SIO) data bit of the SRXCtl register. SPrtcol.5 SCESYN Smart Card External Synchronous mode - Configures External Smart Card interface for synchronous mode. This mode routes the external smart card interface buffers for SIO to SCECtl register bits for direct firmware control. SCLK is generated by the ETU counter. SPrtcol.4 0 SPrtcol.3 TMODE Protocol mode select - 0: T=0, 1: T=1. Determines which smart card protocol is to be used during message processing. SPrtcol.2 CRCEN CRC Enable - 1 = Enabled, 0 = Disabled. Enables the checking/generation of CRC/LRC while in T=1 mode. Has no effect in T=0 mode. If enabled and a message is being transmitted to the smart card, the CRC/LRC will be inserted into the message stream after the last TX byte is transmitted to the smart card. If enabled, CRC/LRC will be checked on incoming messages and the value made available to the firmware via the CRC LS/MS registers. SPrtcol.1 CRCMS CRC Mode Select - 1 = CRC, 0 = LRC. Determines type of checking algorithm to be used. SPrtcol.0 RCVATR Receive ATR - 1 = Enable ATR timeout, 0 = Disable ATR timeout. Set by firmware after the smart card has been turned on and the hardware is expecting ATR. 92 Reserved bit, must always be set to 0. Rev. 1.4 DS_1210F_001 73S1210F Data Sheet SC Clock Configuration Register (SCCLK): 0xFE0F 0x0C This register controls the internal smart card (CLK) clock generation. Table 86: The SCCLK Register MSB LSB - - ICLKFS.5 ICLKFS.4 ICLKFS.3 ICLKFS.2 ICLKFS.1 ICLKFS.0 Bit Symbol Function SCCLK.7 - SCCLK.6 - SCCLK.5 ICLKFS.5 SCCLK.4 ICLKFS.4 SCCLK.3 ICLKFS.3 SCCLK.2 ICLKFS.2 SCCLK.1 ICLKFS.1 SCCLK.0 ICLKFS.0 Internal Smart Card CLK Frequency Select - Division factor to determine internal smart card CLK frequency. MCLK clock is divided by (register value + 1) to clock the ETU divider, and then by 2 to generate CLK. Default ratio is 13. The programmed value in this register is applied to the divider after this value is written, in such a manner as to produce a glitch-free output, regardless of the selection of active interface. A register value = 0 will default to the same effect as register value = 1. External SC Clock Configuration Register (SCECLK): 0xFE10 0x0C This register controls the external smart card (SCLK) clock generation. Table 87: The SCECLK Register MSB LSB - - ECLKFS.5 Bit Symbol SCECLK.7 - SCECLK.6 - SCECLK.5 ECLKFS.5 SCECLK.4 ECLKFS.4 SCECLK.3 ECLKFS.3 SCECLK.2 ECLKFS.2 SCECLK.1 ECLKFS.1 SCECLK.0 ECLKFS.0 Rev. 1.4 ECLKFS.4 ECLKFS.3 ECLKFS.2 ECLKFS.1 ECLKFS.0 Function External Smart Card CLK Frequency Select - Division factor to determine external smart card CLK frequency. MCLK clock is divided by (register value + 1) to clock the ETU divider, and then by 2 to generate SCLK. Default ratio is 13. The programmed value in this register is applied to the divider after this value is written, in such a manner as to produce a glitch-free output, regardless of the selection of active interface. A register value = 0 will default to the same effect as register value = 1. 93 73S1210F Data Sheet DS_1210F_001 Parity Control Register (SParCtl): 0xFE11 0x00 This register provides the ability to configure the parity circuitry on the smart card interface. The settings apply to both integrated smart card interfaces. Table 88: The SParCtl Register MSB LSB - DISPAR BRKGEN BRKDET RETRAN DISCRX INSPE FORCPE Bit Symbol SParCtl.7 - SParCtl.6 DISPAR Disable Parity Check - 1 = disabled, 0 = enabled. If enabled, the UART will check for even parity (the number of 1's including the parity bit is even) on every character. This also applies to the TS during ATR. SParCtl.5 BRKGEN Break Generation Disable - 1 = disabled, 0 = enabled. If enabled, and T=0 protocol, the UART will generate a Break to the smart card if a parity error is detected on a receive character. No Break will be generated if parity checking is disabled. This also applies to TS during ATR. SParCtl.4 BRKDET Break Detection Disable - 1 = disabled, 0 = enabled. If enabled, and T=0 protocol, the UART will detect the generation of a Break by the smart card. SParCtl.3 RETRAN Retransmit Byte - 1 = enabled, 0 = disabled. If enabled and a Break is detected from the smart card (Break Detection must be enabled), the last character will be transmitted again. This bit applies to T=0 protocol. SParCtl.2 DISCRX Discard Received Byte - 1 = enabled, 0 = disabled. If enabled and a parity error is detected (Parity checking must be enabled), the last character received will be discarded. This bit applies to T=0 protocol. SParCtl.1 INSPE Insert Parity Error - 1 = enabled, 0 = disabled. Used for test purposes. If enabled, the UART will insert a parity error in every character transmitted by generating odd parity instead of even parity for the character. SParCtl.0 FORCPE Force Parity Error - 1 = enabled, 0 = disabled. Used for test purposes. If enabled, the UART will generate a parity error on a character received from the smart card. 94 Function Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Byte Control Register (SByteCtl): 0xFE12 0x2C This register controls the processing of characters and the detection of the TS byte. When receiving, a Break is asserted at 10.5 ETU after the beginning of the start bit. Break from the card is sampled at 11 ETU. Table 89: The SByteCtl Register MSB LSB - DETTS Bit Symbol SByteCtl.7 - SByteCtl.6 SByteCtl.5 DIRTS BRKDUR.1 BRKDUR.0 - - - Function DETTS Detect TS Byte - 1 = Next Byte is TS, 0 = Next byte is not TS. When set, the hardware will treat the next character received as the TS and determine if direct or indirect convention is being used. Direct convention is the default used if firmware does not set this bit prior to transmission of TS by the smart card to the firmware. The hardware will check parity and generate a break as defined by the DISPAR and BRKGEN bits in the parity control register. This bit is cleared by hardware after TS is received. TS is decoded prior to the FIFO and is stored in the receive FIFO. DIRTS Direct Mode TS Select - 1 = direct mode, 0 = indirect mode. Set/cleared by hardware when TS is processed indicating either direct/indirect mode of operation. When switching between smart cards, the firmware should write the bit appropriately since this register is not unique to an individual smart card (firmware should keep track of this bit). SByteCtl.4 BRKDUR.1 Break Duration Select - 00 = 1 ETU, 01 = 1.5 ETU, 10 = 2 ETU, 11 = reserved. Determines the length of a Break signal which is generated SByteCtl.3 BRKDUR.0 when detecting a parity error on a character reception in T=0 mode. SByteCtl.2 - SByteCtl.1 - SByteCtl.0 - Rev. 1.4 95 73S1210F Data Sheet DS_1210F_001 FD Control Register (FDReg): 0xFE13 0x11 This register uses the transmission factors F and D to set the ETU (baud) rate. The values in this register are mapped to the ISO 7816 conversion factors as described below. The CLK signal for each interface is created by dividing a high-frequency, intermediate signal (MSCLK) by 2. The ETU baud rate is created by dividing MSCLK by 2 times the Fi/Di ratio specified by the codes below. For example, if FI = 0001 and DI = 0001, the ratio of Fi/Di is 372/1. Thus the ETU divider is configured to divide by 2 * 372 = 744. The maximum supported F/D ratio is 4096. Table 90: The FDReg Register MSB LSB FVAL.3 FVAL.2 FVAL.1 FVAL.0 DVAL.3 DVAL.2 DVAL.1 DVAL.0 Table 91: The FDReg Bit Functions Bit Symbol FDReg.7 FVAL.3 FDReg.6 FVAL.2 FDReg.5 FVAL.1 FDReg.4 FVAL.0 FDReg.3 DVAL.3 FDReg.2 DVAL.2 FDReg.1 DVAL.1 FDReg.0 DVAL.0 Function Refer to the Table 93 above. This value is converted per the table to set the divide ratio used to generate the baud rate (ETU). Default, also used for ATR, is 0001 (Fi = 372). This value is used by the selected interface. Refer to Table 93 above. This value is used to set the divide ratio used to generate the smart card CLK. Default, also used for ATR, is 0001 (Di = 1). Table 92: Divider Ratios Provided by the ETU Counter FI (code) 0000 0001 0010 0011 0100 0101 0110 0111 Fi (ratio) 372 372 558 744 1116 1488 1860 1860 FCLK max 4 5 6 8 12 16 20 20 FI(code) 1000 1001 1010 1011 1100 1101 1110 1111 Fi(ratio) 512 512 768 1024 1536 2048 2048 2048 FCLK max 5 5 7.5 10 15 20 20 20 DI(code) 0000 0001 0010 0011 0100 0101 0110 0111 Di(ratio) 1 1 2 4 8 16 32 32 DI(code) 1000 1001 1010 1011 1100 1101 1110 1111 Di(ratio) 12 20 16 16 16 16 16 16 Note: values marked with are not included in the ISO definition and arbitrary values have been assigned. The values given below are used by the ETU divider to create the ETU clock. The entries that are not shaded will result in precise CLK/ETU per ISO requirements. Shaded areas are not precise but are within 1% of the target value. 96 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Table 93: Divider Values for the ETU Clock Di code 0001 0010 0011 0100 1000 0101 1001 0110 Di code 0001 0010 0011 0100 1000 0101 1001 0110 Rev. 1.4 Fi code F D 1 2 4 8 12 16 20 32 0000 372 0001 372 0010 558 0011 744 0100 1116 0101 1488 744 372 186 93 62 47 37 23 744 372 186 93 62 47 37 23 1116 558 279 138 93 70 56 35 1488 744 372 186 124 93 74 47 2232 1116 558 279 186 140 112 70 2976 1488 744 372 248 186 149 93 Fi code F D 1 2 4 8 12 16 20 32 0110 1860 1001 512 1010 768 1011 1024 1100 1536 1101 2048 3720 1860 930 465 310 233 186 116 1024 512 256 128 85 64 51 32 1536 768 384 192 128 96 77 48 2048 1024 512 256 171 128 102 64 3072 1536 768 384 256 192 154 96 4096 2048 1024 512 341 256 205 128 97 73S1210F Data Sheet DS_1210F_001 CRC MS Value Registers (CRCMsB): 0xFE14 0xFF, (CRCLsB): 0xFE15 0xFF Table 94: The CRCMsB Register MSB CRC.15 LSB CRC.14 CRC.13 CRC.12 CRC.11 CRC.10 CRC.9 MSB CRC.7 CRC.8 LSB CRC.6 CRC.5 CRC.4 CRC.3 CRC.2 CRC.1 CRC.0 The 16-bit CRC value forms the TX CRC word in TX mode (write value) and the RX CRC in RX mode (read value). The initial value of CRC to be used when generating a CRC to be transmitted at the end of a message (after the last TX byte is sent) when enabled in T=1 mode. Should be reloaded at the beginning of every message to be transmitted. When using CRC, both CRC registers should be initialized to FF. When using LRC, the CRCLsB value register should be loaded to 00. When receiving a message, the firmware should load this with the initial value and then read this register to get the final value at the end of the message. These registers need to be reloaded for each new message to be received. When in LRC mode, bits (7:0) are used and bits (15:8) are undefined. During LRC/CRC checking and generation, this register is updated with the current value and can be read to aid in debugging. This information will be transmitted to the smart card using the timing specified by the Guard Time register. When checking CRC/LRC on an incoming message (CRC/LRC is checked against the data and CRC/LRC), the firmware reads the final value after the message has been received and determines if an error occurred (= 0x1D0F (CRC) no error, else error; = 0 (LRC) no error, else error). When a message is received, the CRC/LRC is stored in the FIFO. The polynomial used to generate and 16 12 5 check CRC is x + x + x +1. When in indirect convention, the CRC is generated prior to the conversion into indirect convention. When in indirect convention, the CRC is checked after the conversion out of indirect convention. For a given message, the CRC generated (and readable from this register) will be the same whether indirect or direct convention is used to transmit the data to the smart card. The CRCLsB / CRCMsB registers will be updated with CRC/LRC whenever bits are being received or transmitted from/to the smart card (even if CRCEN is not set and in mode T1). They are available to the firmware to use if desired. 98 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Block Guard Time Register (BGT): 0xFE16 0x10 This register contains the Extra Guard Time Value (EGT) most-significant bit. The Extra Guard Time indicates the minimum time between the leading edges of the start bit of consecutive characters. The delay is depends on the T=0/T=1 mode. Used in transmit mode. This register also contains the Block Guard Time (BGT) value. Block Guard Time is the minimum time between the leading edge of the start bit of the last character received and the leading edge of the start bit of the first character transmitted. This should not be set less than the character length. The transmission of the first character will be held off until BGT has elapsed regardless of the TX data and TX/RX control bit timing. Table 95: The BGT Register MSB LSB EGT.8 - - Bit Symbol BGT.7 EGT.8 BGT.6 - BGT.5 - BGT.4 BGT.4 BGT.3 BGT.3 BGT.2 BGT.2 BGT.1 BGT.1 BGT.0 BGT.0 BGT.4 BGT.3 BGT.1 BGT.2 BGT.0 Function Most-significant bit for 9-bit EGT timer. See the EGT register. Time in ETUs between the start bit of the last received character to start bit of the first character transmitted to the smart card. Default value is 22. Extra Guard Time Register (EGT): 0xFE17 0x0C This register contains the Extra Guard Time Value (EGT) least-significant byte. The Extra Guard Time indicates the minimum time between the leading edges of the start bit of consecutive characters. The delay depends on the T=0/T=1 mode. Used in transmit mode. Table 96: The EGT Register MSB LSB EGT.7 EGT.6 Bit EGT.5 EGT.4 EGT.3 EGT.1 EGT.2 EGT.0 Function EGT.7 EGT.6 EGT.5 EGT.4 EGT.3 EGT.2 Time in ETUs between start bits of consecutive characters. In T=0 mode, the minimum is 1. In T=0, the leading edge of the next start bit may be delayed if there is a break detected from the smart card. Default value is 12. In T=0 mode, regardless of the value loaded, the minimum value is 12, and for T=1 mode, the minimum value is 11. EGT.1 EGT.0 Rev. 1.4 99 73S1210F Data Sheet DS_1210F_001 Block Wait Time Registers (BWTB0): 0xFE1B 0x00, (BWTB1): 0xFE1A 0x00, (BWTB2): 0xFE19 0x00, (BWTB3): 0xFE18 0x00 These registers are used to set the Block Waiting Time(27:0) (BWT). All of these parameters define the maximum time the 73S1210F will have to wait for a character from the smart card. These registers serve a dual purpose. When T=1, these registers are used to set up the block wait time. The block wait time defines the time in ETUs between the beginning of the last character sent to smart card and the start bit of the first character received from smart card. It can be used to detect an unresponsive card and should be loaded by firmware prior to writing the last TX byte. When T=0, these registers are used to set up the work wait time. The work wait time is defined as the time between the leading edge of two consecutive characters being sent to or from the card. If a timeout occurs, an interrupt is generated to the firmware. The firmware can then take appropriate action. A Wait Time Extension (WTX) is supported with the 28bit BWT. Table 97: The BWTB0 Register MSB LSB BWT.7 BWT.6 BWT.5 BWT.4 BWT.3 BWT.1 BWT.2 BWT.0 Table 98: The BWTB1 Register MSB LSB BWT.15 BWT.14 BWT.13 BWT.12 BWT.11 BWT.10 BWT.9 BWT.8 Table 99: The BWTB2 Register MSB LSB BWT.23 BWT.22 BWT.21 BWT.20 BWT.19 BWT.18 BWT.17 BWT.16 Table 100: The BWTB3 Register MSB LSB - - - - BWT.27 BWT.26 BWT.25 BWT.24 Character Wait Time Registers (CWTB0): 0xFE1D 0x00, (CWTB1): 0xFE1C 0x00 These registers are used to hold the Character Wait Time(15:0) (CWT) or Initial Waiting Time(15:0) (IWT) depending on the situation. Both the IWT and the CWT measure the time in ETUs between the leading edge of the start of the current character received from the smart card and the leading edge of the start of the next character received from the smart card. The only difference is the mode in which the card is operating. When T=1 these registers are used to configure the CWT and these registers configure the IWT when the ATR is being received. These registers should be loaded prior to receiving characters from the smart card. Firmware must manage which time is stored in the register. If a timeout occurs, an interrupt is generated to the firmware. The firmware can then take appropriate action. Table 101: The CWTB0 Register MSB CWT.7 LSB CWT.6 CWT.5 CWT.4 CWT.3 CWT.1 CWT.2 CWT.0 Table 102: The CWTB1 Register MSB CWT.15 100 LSB CWT.14 CWT.13 CWT.12 CWT.11 CWT.10 CWT.9 CWT.8 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet ATR Timeout Registers (ATRLsB): 0xFE20 0x00, (ATRMsB): 0xFE1F 0x00 These registers form the ATR timeout (ATRTO [15:0]) parameter. Time in ETU between the leading edge of the first character and leading edge of the last character of the ATR response. Timer is enabled when the RCVATR is set and starts when leading edge of the first start bit is received and disabled when the RCVATR is cleared. An ATR timeout is generated if this time is exceeded. Table 103: The ATRLsB Register MSB LSB ATRTO.7 ATRTO.6 ATRTO.5 ATRTO.4 ATRTO.3 ATRTO.1 ATRTO.2 ATRTO.0 Table 104: The ATRMsB Register MSB LSB ATRTO.15 ATRTO.14 ATRTO.13 ATRTO.12 ATRTO.11 ATRTO.10 ATRTO.9 ATRTO.8 TS Timeout Register (STSTO): 0xFE21 0x00 The TS timeout is the time in ETU between the de-assertion of smart card reset and the leading edge of the TS character in the ATR (when DETTS is set). The timer is started when smart card reset is de-asserted. An ATR timeout is generated if this time is exceeded (MUTE card). Table 105: The STSTO Register MSB LSB TST0.7 TST0.6 TST0.5 TST0.4 TST0.3 TST0.1 TST0.2 TST0.0 Reset Time Register (RLength): 0xFE22 0x70 Time in ETUs that the hardware delays the de-assertion of RST. If set to 0 and RSTCRD = 0, the hardware adds no extra delay and the hardware will release RST after VCCOK is asserted during power-up. If set to 1, it will delay the release of RST by the time in this register. When the firmware sets the RSTCRD bit, the hardware will assert reset (RST = 0 on pin). When firmware clears the bit, the hardware will release RST after the delay specified in Rlen. If firmware sets the RSTCRD bit prior to instructing the power to be applied to the smart card, the hardware will not release RST after power-up until RLen after the firmware clears the RSTCRD bit. This provides a means to power up the smart card and hold it in reset until the firmware wants to release the RST to the selected smart card. Works with the selected smart card interface. Table 106: The RLength Register MSB RLen.7 Rev. 1.4 LSB RLen.6 RLen.5 RLen.4 RLen.3 RLen.1 RLen.2 RLen.0 101 73S1210F Data Sheet DS_1210F_001 Shaded locations indicate functions that are not provided in the synchronous mode. Table 107: Smart Card SFR Table Name SCSel SCInt Address FE00 FE01 SCIE FE02 VccCtl VCCTmr CRDCtl STXCtl STXData SRXCtl SRXData SCCtl SCECtl SCDIR SPrtcol SCCLK SCECLK SParCtl SByteCtl FDReg CRCMsB CRCLsB BGT EGT BWTB3 BWTB2 BWTB1 BWTB0 CWTB1 CWTB0 ATRMsB ATRLsB STSTO RLength FE03 FE04 FE05 FE06 FE07 FE08 FE09 FE0A FE0B FE0C FE0D FE0F FE10 FE11 FE12 FE13 FE14 FE15 FE16 FE17 FE18 FE19 FE1A FE1B FE1C FE1D FE1F FE20 FE21 FE22 102 b7 b6 b5 WAITTO/ CRDEVT VCCTMR RLIEN WTOI/ CDEVNT VTMREN RLIEN VCCSEL.1 VCCSEL.0 VDDFLT OFFTMR(3:0) DEBOUN CDETEN I2CMODE TXFULL BIT9DAT LASTRX RSTCRD IO SIO SCISYN MOD9/8B SCESYN DISPAR BRKGEN DETTS DIRTS FVAL(3:0) EGT8 b4 RXDAVl b3 b2 SelSC(1:0) TXEVNT TXSENT RXDAEN TXEVEN RDYST VCCOK TXSNTEN b1 BYPASS TXERR b0 RXERR TXERR RXERR SCPWRDN VCCTMR(3:0) PUENB PDEN LASTTX TX/RXB DETPOL TXEMTY TXUNDR TXDATA(7:0) CRCERR RXFULL RXEMTY RXOVRR RXDATA(7:0) IOD C8 C4 CLKLVL SIOD SCLKLVL C8D C4D 0 TMODE CRCEN CRCMS ICLKFS(5:0) ECLKFS(5:0) BRKDET RTRAN DISCRX INSPE BRKDUR (1:0) DVAL (3:0) CRC(15:8) CRC(7:0) BGT(4:0) EGT(7:0) BWT(27:24) BWT(23:16) BWT(15:8) BWT(7:0) CWT(15:8) CWT(7:0) ATRTO(15:8) ATRTO(7:0) TSTO(7:0) RLen(7:0) CARDIN BREAKD PARITYE CLKOFF SCLKOFF RCVATR FORCPE Rev. 1.4 DS_1210F_001 73S1210F Data Sheet 1.7.16 VDD Fault Detect Function The 73S1210F contains a circuit to detect a low-voltage condition on the supply voltage VDD. If enabled, it will deactivate the active internal smart card interface when VDD falls below the VDD Fault threshold. The register configures the VDD Fault threshold for the nominal default of 2.3V* or a user selectable threshold. The user's code may load a different value using the FOVRVDDF bit = 1 after the power-up cycle has completed. VDDFault Control Register (VDDFCtl): 0xFFD4 0x00 Table 108: The VDDFCtl Register MSB LSB - FOVRVDDF VDDFLTEN Bit Symbol VDDFCtl.7 - - STXDAT.3 VDDFTH.2 VDDFTH.1 VDDFTH.0 Function Setting this bit high will allow the VDDFLT(2:0) bits set in this register to control VDDFCtl.6 FOVRVDDF the VDDFault threshold. When this bit is set low, the VDDFault threshold will be set to the factory default setting of 2.3V*. VDDFCtl.5 VDDFLTEN VDDFCtl.4 - VDDFCtl.3 - VDDFCtl.2 VDDFTH.2 VDDFCtl.1 VDDFTH.1 VDDFCtl.0 VDDFTH.0 Set = 1 will disable VDD Fault operation. VDD Fault Threshold. Bit Value(2:0) 000 001 010 011 100 101 110 111 VDDFault Voltage 2.3 (nominal default) 2.4 2.5 2.6 2.7 2.8 2.9 3.0 * Note: The VDD Fault factory default can be set to any threshold as defined by bits VDDFTH(2:0). The 73S1210F has the capability to burn fuses at the factory to set the factory default to any of these voltages. Contact Teridian for further details. Rev. 1.4 103 73S1210F Data Sheet DS_1210F_001 2 Typical Application Schematic R1 Y1 1M 12.000MHz C2 C1 22pF 22pF VDD Host Serial TX D1 Host Serial RX R2 R3 3K 3K LED C3 0.1uF + C4 10uF Input Power Supply (2.7 - 6.5V) 3 1 3 1 F3 A SW_MOM 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 SW_MOM 3 3 2 S10 3 1 USR6 B UP SW_MOM SW_MOM SW_MOM 3 1 3 1 3 1 1 SW_MOM S9 S8 S7 S6 1 SW_MOM 3 4 6 5 3 1 3 USR5 USR4 USR3 USR2 C DOWN SW_MOM SW_MOM SW_MOM SW_MOM S16 1 3 1 3 1 S15 S14 S13 S12 1 SW_MOM 3 1 3 1 7 S21 1 3 1 3 D SW_MOM SW_MOM USR1 3 CLR 9 8 SW_MOM SW_MOM S20 S19 S18 S17 1 TXD COL4 USR7 ROW0 ROW1 USR6 ROW2 GND N/C N/C VDD USR5 USR4 USR3 USR2 ROW3 USR1 SW_MOM . 1 3 1 SW_MOM SW_MOM SW_MOM S27 S28 S29 3 ENTER / 0 S26 1 3 1 3 73S1210F R4 SLUG VDD GND LIN VPC VBAT ON_OFF VBUS I/O C4/AUX1 C8/AUX2 VCC RST GND CLK VP PRES OFF_REQ 69 10k 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 L1 ON_OFF SW 2 SMARTCARD SLOT #1 VDD J1 1 2 3 4 5 6 7 8 R5 0 C7 9 10 4.7uF R6 C8 C9 20k 27p 27p C10 VCC RST CLK C4 GND VPP I/O C8 SW-1 SW-2 Smart Card Connector E SW_MOM C6 10uF 10uH S11 1 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 3 S25 S24 S23 S22 1 U1 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 3 1 ON/CE SW_MOM SW_MOM 3 1 3 F2 F1 SW_MOM RXD COL3 ANAIN COL2 COL1 COL0 X12OUT X12IN GND N/C N/C SDA SCL LED0 ISBR SEC RESET 1 C5 0.1uF VDD S5 S4 S3 S2 S1 USR0 ROW4 ROW5 ERST TCLK VDD TBUS3 GND RXTX TBUS2 SCLK TBUS1 SIO INT3 INT2 TBUS0 TEST 30-SWITCH KEYPAD 0.47uF SW_MOM W SW_MOM 1 3 1 3 1 3 1 3 Z Y X VDD F SW_MOM SW_MOM SW_MOM USR0 3 1 S31 S30 SW_MOM C11 VDD 24 23 22 21 20 19 18 17 C13 C14 0.1uF 0.1uF 0.1uF 1 NC 100 RV1 2 D2 10K 5.0V Zener C15 + C19 1uF 0.1uF NC I/OUC AUX1UC AUX2UC SAD0 SAD1 SAD2 NC NC VCC RST CLK GND AUX1 AUX2 NC J2 16 15 14 13 12 11 10 9 1 2 3 4 5 6 7 8 R7 0 9 10 C16 C17 27p 27p C18 VCC RST CLK C4 GND VPP I/O C8 SW-1 SW-2 Smart Card Connector 1.0uF VDD 3 CW 15 DB5 DB7 DB3 DB4 DB6 13 14 USR3 USR2 12 11 USR0 USR1 DB1 E DB0 R/W* RS DB2 9 10 8 6 7 5 4 GND VDD USR6 USR5 USR4 3 1 2 VO R8 25 26 27 28 29 30 31 32 XTALOUT XTALIN INT GND VDD SDA SCL VDDF_ADJ C12 GND GND VPC NC NC NC PRES I/O U2 SMARTCARD SLOT #2 73S8010R 1 2 3 4 5 6 7 8 OPTIONAL LCD DISPLAY SYSTEM 16 CHARACTER BY 2 LINES 0.1uF U3 R9 LCD BRIGHTNESS ADJUST 20k Figure 25: 73S1210F Typical Application Schematic 104 Rev. 1.4 DS_7310F_001 73S1210F Data Sheet 3 Electrical Specification 3.1 Absolute Maximum Ratings Operation outside these rating limits may cause permanent damage to the device. The smart card interface pins are protected against short circuits to VCC, ground, and each other. Parameter Rating DC Supply voltage, VDD -0.5 to 4.0 VDC Supply Voltage VPC -0.5 to 6.6 VDC Supply Voltage VBUS -0.5 to 6.6 VDC Supply Voltage VBAT -0.5 to 6.6 VDC Storage Temperature -60 to 150C Pin Voltage (except card interface) -0.3 to (VDD+0.5) VDC Pin Voltage (card interface) -0.3 to (VCC+0.5) VDC ESD tolerance (except card interface) +/- 2KV ESD tolerance (card interface) +/- 7KV Pin Current 200 mA Note: ESD testing on smart card pins is HBM condition, 3 pulses, each polarity referenced to ground. Note: Smart Card pins are protected against shorts between any combinations of Smart Card pins. 3.2 Recommended Operating Conditions Unless otherwise noted all specifications are valid over these temperatures and supply voltage ranges: Parameter Rating Supply Voltage VPC 2.7 to 6.5 VDC Supply Voltage VBUS 4.4 to 5.5 VDC Supply Voltage VBAT 4.0 to 6.5 VDC Ambient Operating Temperature (Ta) -40C to +85C Rev. 1.4 105 73S1210F Data Sheet 3.3 DS_1210F_001 Digital IO Characteristics These requirements pertain to digital I/O pin types with consideration of the specific pin function and configuration. The LED(1:0) pins have pull-ups that may be enabled. The Row pins have 100k pullups. Symbol Parameter Conditions Min. Voh Output level, high Ioh = -2mA 0.8 * VDD OFF_REQ pin - IOH = -1mA VDD - 0.45 Iol = 2mA 0 Vol Output level, low Typ. Max. Unit VDD V V OFF_REQ pin - Iol = 2mA 0.3 V 0.45 V Vih Input voltage, high 2.7v < VDD <3.6v 1.8 VDD +0.3 V Vil Input voltage, low 2.7v < VDD <3.6v -0.3 0.6 V RESET, ON_OFF,PRES pins -0.3 0.8 V 0 < Vin < VDD -5 5 A Ileak Leakage current All output modes disabled, pull-up/downs disabled Ipu Pull-up current If provided and enabled, A -5 Vout < 0.1v Ipd Pull-down current If provided and enabled, 5 A Max. Unit Vout > VDD - 0.1v Symbol Parameter Iled LED drive current Vout = 1.3V, 2.7v < VDD < 3.6v 2 4 10 Iolkrow Keypad row output low current 0.0v < Voh < 0.1v when pull-up R is enabled 40 100 A Iolkcol Keypad column output high current 0.0v < Voh < 0.1v when col. is pulled low 1.5 3 mA 106 Conditions Min. Typ. mA Rev. 1.4 DS_1210F_001 3.4 73S1210F Data Sheet Oscillator Interface Requirements Symbol Parameter Condition Min Typ. Max Unit High-Frequency Oscillator (Xin) Parameters. Xin Is Used As Input For External Clock For Test Purposes Only. A Resistor Connecting x12in To x12out Is Required, Value = 1m. VILX12IN Input Low Voltage - X12IN VIHX12IN Input High Voltage - X12IN IILXTAL Input Current -X12IN Fxtal Crystal resonant frequency 3.5 -0.3 1.5 0.3*VDD V 0.7*VDD 1.6 Vdd+.0.3 V GND < Vin < Vdd -10 10 A Fundamental mode 6 12 MHz Max Unit +3% V DC Characteristics: Analog Input Symbol Parameter VTHTOL Voltage Threshold Tolerance Rev. 1.4 Condition Min Selected Threshold Value -3% Typ. 107 73S1210F Data Sheet 3.6 DS_1210F_001 Smart Card Interface Requirements Symbol Parameter Condition Min Typ. Max Unit Card Power Supply (VCC) Regulator General conditions, -40C < T < 85C, 4.75V < VPC < 6.0V, 2.7V < VDD < 3.6V VCC Card supply Voltage including ripple and noise VCCrip VCC Ripple ICCmax Card supply output current ICCF ICC fault current Isc Maximum current prior to shut-down Inactive mode -0.1 0.1 V Inactive mode, ICC = 1mA -0.1 0.4 V Active mode; ICC <65mA; 5V 4.65 5.25 V Active mode; ICC < 65mA; 3V 2.85 3.15 V Active mode; ICC < 40mA; 1.8V 1.68 1.92 V Active mode; single pulse of 100mA for 2s; 5V, fixed load = 25mA 4.6 5.25 V Active mode; single pulse of 100mA for 2s; 3V, fixed load = 25mA 2.76 3.15 V Active mode; current pulses of 40nAs with peak |ICC | <200mA, t <400ns; 5V 4.6 5.25 V Active mode; current pulses of 40nAs with peak |ICC | <200mA,t <400ns; 3V 2.7 3.15 V Active mode; current pulses of 20nAs with peak |ICC | <100mA,t <400ns; 1.8V 1.62 1.92 V fRIPPLE = 20kHz - 200MHz 350 mV Static load current, VCC>1.65 40 mA Static load current, VCC>4.6V or 2.7V as selected 65 mA Class A, B (5V and 3V) 100 180 Class C (1.8V) 60 130 Load current limit prior to Vcc shut-down 80 150 60 130 Load current limit prior to Vcc shut-down for Vcc = 1.8V mA mA. mA VSR Vcc slew rate, rise Rise rate on activate C = 0.47F 0.12 .30 0.50 V/s VSF Vcc slew rate, fall Fall rate on deactivate, C = 0.47F 0.15 .30 1.20 V/s 5V operation, Vcc rising 4.6 V 3V operation, Vcc rising 2.75 V 1.8V operation, Vcc rising 1.65 V Vrdy 108 Vcc ready voltage (VCCOK = 1) Rev. 1.4 DS_1210F_001 Symbol 73S1210F Data Sheet Parameter Condition Min Typ. Max Unit Interface Requirements - Data Signals: I/O, AUX1 and AUX2 IOH = 0 0.9 * VCC VCC+0.1 V IOH = -40A 0.75 VCC VCC+0.1 V 0.15 *VCC V 0.6 * VCC VCC+0.30 V -0.15 0.2 * VCC V IOL = 0 0.1 V IOL = 1mA 0.3 V VIH = VCC 10 A Input current, low VIL = 0 0.65 mA IIL Input current, low VIL = 0 0.7 mA ISHORTL Short circuit output current For output low, shorted to VCC through 33 15 mA ISHORTH Short circuit output current For output high, shorted to ground through 33 15 mA tR, tF Output rise time, fall times For I/O, AUX1, AUX2, CL = 80pF, 10% to 90%. For I/OUC, AUX1UC, AUX2UC, CL = 50Pf, 10% to 90%. 100 ns tIR, tIF Input rise, fall times 1 s RPU Internal pull-up resistor 14 k FDMAX Maximum data rate 1 MHz VOH Output level, high VOL Output level, low VIH Input level, high VIL Input level, low VINACT Output voltage when outside of session ILEAK Input leakage IIL IOL = 1mA Output stable for >200ns 8 11 Reset and Clock for card interface, RST, CLK VOH Output level, high IOH = -200A 0.9 * VCC VCC V VOL Output level, low IOL= 200A 0 0.15 *VCC V VINACT Output voltage when outside of session IOL = 0 0.1 V IOL = 1mA 0.3 V IRST_LIM Output current limit, RST 30 ICLK_LIM Output current limit, CLK 70 mA CL = 35pF for CLK, 10% to 90% 8 ns CL = 200pF for RST, 10% to 90% 100 ns 55 % tR, tF Output rise time, fall time CL = 35pF, FCLK Duty cycle for CLK 20MHz, CLKIN duty 45 cycle is 48% to 52%. Rev. 1.4 109 73S1210F Data Sheet 3.7 DC Characteristics Symbol Parameter Supply Current @ VPC = 2.7V (VBUS and VBAT unconnected) Supply Current @ VPC = 3.3V (VBUS and VBAT unconnected) IPC Supply Current @ VPC = 5.0V (VBUS and VBAT unconnected) Supply Current @ VVBUS = 4.4V Supply Current @ VVBUS = 5.0V IVBUS Supply Current @ VVBUS = 5.5V Supply Current @ VVBAT = 4.0V (VBUS = 0V) Supply Current @ VVBAT = 5.0V (VBUS = 0V) IVBAT Supply Current @ VVBAT = 6.5V (VBUS = 0V) VDD* 110 DS_1210F_001 VDD Supply Voltage Condition Min Typ. Max Unit CPU clock @ 24MHz 44 55 66 mA CPU clock @ 12MHz 31 38 46 mA CPU clock @ 6MHz 23 29 35 mA CPU clock @ 3.69MHz 20 25 30 mA CPU clock @ 24MHz 34 43 51 mA CPU clock @ 12MHz 24 30 36 mA CPU clock @ 6MHz 18 22 27 mA CPU clock @ 3.69MHz 16 19 23 mA CPU clock @ 24MHz 20 25 30 mA CPU clock @ 12MHz 14 18 21 mA CPU clock @ 6MHz 11 13 16 mA CPU clock @ 3.69MHz 9 12 14 mA CPU clock @ 24MHz 16 20 24 mA CPU clock @ 12MHz 11 14 17 mA CPU clock @ 6MHz 8 10 13 mA CPU clock @ 3.69MHz 7 9 11 mA CPU clock @ 24MHz 16 19 23 mA CPU clock @ 12MHz 11 14 17 mA CPU clock @ 6MHz 8 10 13 mA CPU clock @ 3.69MHz 7 9 11 mA CPU clock @ 24MHz 16 20 23 mA CPU clock @ 12MHz 11 14 17 mA CPU clock @ 6MHz 8 11 13 mA CPU clock @ 3.69MHz 7 9 11 mA CPU clock @ 24MHz 28 34 41 mA CPU clock @ 12MHz 19 24 28 mA CPU clock @ 6MHz 14 18 21 mA CPU clock @ 3.69MHz 12 15 19 mA CPU clock @ 24MHz 20 26 31 mA CPU clock @ 12MHz 14 18 21 mA CPU clock @ 6MHz 11 13 16 mA CPU clock @ 3.69MHz 9 12 14 mA CPU clock @ 24MHz 16 20 24 mA CPU clock @ 12MHz 11 14 17 mA CPU clock @ 6MHz 8 10 13 mA CPU clock @ 3.69MHz 7 9 11 mA 2.7V < VPC < 6.5V, IVDD < 40mA. 3.0 3.3 3.6 V Rev. 1.4 DS_1210F_001 IDD_IN 73S1210F Data Sheet Supply Current - pins 28 + 40 (internal consumption - digital core) IDD_OUT Supply Current - pin 68 (available to external circuitry) IVBUS Supply Current from VBUS IVBAT IVPC Supply Current from VBAT or VPC VBUSON VBUS detection threshold CPU clock @ 24MHz 29 33.5 mA CPU clock @ 12MHz 21 24 mA CPU clock @ 6MHz 15.5 18 mA CPU clock @ 3.69MHz 13.5 15.5 mA Power down (-40 to 85C) 8 50 A Power down (25C) 6 15 A 20 mA Circuit ON VCC off, IDDINTERNAL < 20A 0.2 0.4 mA Circuit OFF 0.01 1 A VBUSIDIS VBUS discharge current 3.5 V 50 A External Capacitor Values CVPC External filter capacitor for VPC 8.0 10.0 12.0 F CVP External filter capacitor for VP 2.0 4.7 10.0 F CVDD* External filter capacitors for VDD 0.2 1.0 F CVCC External filter capacitor for VCC CVCC should be ceramic with low ESR (<100M). 0.2 0.47 1.0 F Min Typ. Max Unit 150 mA *Note: Recommend on 0.1F for each VDD pin. 3.8 Current Fault Detection Circuits Symbol Parameter IVPmax VP over current fault IDDmax VDD over-current limit 40 100 mA ICCF Card overcurrent fault 80 150 mA ICCF1P8 Card overcurrent fault 60 130 mA Rev. 1.4 Condition VCC = 1.8V 111 73S1210F Data Sheet DS_1210F_001 4 Equivalent Circuits VDD X12LIN X12OUT ESD ESD ENABLE TTL To circuit Figure 26: 12 MHz Oscillator Circuit VDD ENABLEb X32OUT >1MEG X32LIN ESD ESD TTL To circuit Figure 27: 32KHz Oscillator Circuit 112 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet VDD STRONG PFET Output Disable PIN ESD Data From circuit TTL To circuit STRONG NFET Figure 28: Digital I/O Circuit VDD STRONG PFET Output Disable PIN Data From circuit ESD STRONG NFET Figure 29: Digital Output Circuit Rev. 1.4 113 73S1210F Data Sheet DS_1210F_001 VDD VERY WEAK PFET Pull-up Disable STRONG PFET Output Disable PIN ESD Data From circuit STRONG NFET TTL To circuit Figure 30: Digital I/O with Pull Up Circuit VDD STRONG PFET Output Disable PIN ESD Data From circuit Pull-down Enable TTL To circuit STRONG NFET VERY WEAK NFET Figure 31: Digital I/O with Pull Down Circuit 114 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet TTL To circuit PIN ESD Figure 32: Digital Input Circuit VDD VERY WEAK PFET Pull-up Disable STRONG PFET ESD Output Disable PIN ESD Data From circuit TTL To circuit STRONG NFET VERY WEAK NFET Pull-down Enable Figure 33: OFF_REQ Interface Circuit VDD Pull-up Disable STRONG PFET 100k OHM Output Disable PIN ESD Data From circuit TTL To circuit STRONG NFET Figure 34: Keypad Row Circuit Rev. 1.4 115 73S1210F Data Sheet DS_1210F_001 VDD 1200 OHMS MEDIUM PFET Output Disable PIN ESD Data From circuit TTL To circuit STRONG NFET Figure 35: Keypad Column Circuit VDD STRONG PFET Pullup Disable PIN ESD Data From circuit TTL To circuit STRONG NFET Current Value Control 0, 2, 4, 10mA Figure 36: LED Circuit 116 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet This buffer has a special input threshold: Vih>0.7*VDD To Circuit Logic PIN ESD R= 20k Figure 37: Test and Security Pin Circuit To Comparator Input PIN ESD Figure 38: Analog Input Circuit VCC STRONG PFET ESD From circuit PIN ESD STRONG NFET Figure 39: Smart Card Output Circuit Rev. 1.4 117 73S1210F Data Sheet DS_1210F_001 VCC STRONG PFET RL=11K ESD 125ns DELAY IO PIN From circuit To circuit CMOS STRONG NFET ESD Figure 40: Smart Card I/O Circuit VDD TTL ESD To circuit PIN VERY WEAK NFET Pull-down Enable ESD Figure 41: PRES Input Circuit VDD VERY WEAK PFET To circuit ESD TTL Pull-up Disable Pull-down Enable PIN ESD Figure 42: PRESB Input Circuit 118 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet VPC R= 24k To Circuit Logic PIN ESD Figure 43: ON_OFF Input Circuit Rev. 1.4 119 73S1210F Data Sheet DS_1210F_001 5 Package Pin Designation 5.1 68-pin QFN Pinout SEC RESET 2 1 3 4 SDA SCL LED0 ISBR 5 N/C N/C 8 6 XI2IN GND 10 7 X12OUT 11 9 COL1 COL0 12 13 ANA_IN COL2 15 14 RXD COL3 16 17 CAUTION: Use handling procedures necessary for a static sensitive component TXD 18 68 VDD COL4 19 67 GND USR7 20 66 LIN ROW0 ROW1 USR6 21 65 22 64 VPC VBAT 23 63 ON_OFF ROW2 GND N/C 24 62 VBUS 61 N/C VDD 27 59 IO AUX1 AUX2 58 VCC USR5 USR4 USR3 29 57 30 56 31 55 RST GND CLK USR2 ROW3 USR1 32 54 33 53 34 52 51 43 RXTX TBUS2 50 42 GND VP PRES OFF_REQ TBUS0 TEST 41 VDD TBUS3 49 40 48 39 TCLK 47 38 60 SIO INT3 INT2 37 ROW5 ERST 46 36 ROW4 44 35 USR0 28 SCLK TBUS1 26 45 TERIDIAN 73S1210F 25 Figure 44: 73S1210F 68 QFN Pinout 120 Rev. 1.4 DS_1210F_001 5.2 73S1210F Data Sheet 44-pin QFN Pinout VDD GND LIN 3 1 RESET 4 2 SCL LED0 6 5 SDA 7 8 XI2IN GND X12OUT 10 9 RXD 11 CAUTION: Use handling procedures necessary for a static sensitive component. VPC ON_OFF TXD USR7 12 44 13 43 USR6 GND 14 42 15 41 IO AUX1 VDD USR5 USR4 16 40 AUX2 39 USR3 19 USR2 20 36 VCC RST GND CLK USR1 21 35 USR0 22 34 VP PRES 33 32 27 RXTX SCLK 31 26 GND 30 25 VDD 37 INT3 INT2 TEST OFF_REQ 24 TCLK 38 SIO 23 ERST 18 29 17 28 TERIDIAN 73S1210F Figure 45: 73S1210F 44 QFN Pinout Rev. 1.4 121 73S1210F Data Sheet DS_1210F_001 6 Packaging Information 6.1 68-Pin QFN Package Outline Notes: 6.3mm x 6.3mm exposed pad area must remain UNCONNECTED (clear of PCB traces or vias). Controlling dimensions are in mm. 0.65 8.00 7.75 0.85 0.2 0.00/0.05 68 1 2 3 7.75 8.00 TOP VIEW 12 SEATING PLANE 8.00 0.42 0.24/0.60 6.15/6.45 68 0.00/0.05 1 2 0.45 SIDE VIEW PIN#1 ID R0.20 6.30 0.20 0.15/0.25 3 0.42 0.24/0.60 SECTION "C-C" 6.30 SCALE: NONE 6.40 8.00 6.15/6.45 C C CL 6.40 0.40 TERMINAL TIP FOR ODD TERMINAL/SIDE BOTTOM VIEW Figure 46: 73S1210F 68 QFN Mechanical Drawing 122 Rev. 1.4 DS_1210F_001 6.2 73S1210F Data Sheet 44-Pin QFN Package Outline Notes: 5.1mm x 5.1mm exposed pad area must remain UNCONNECTED (clear of PCB traces or vias). Controlling dimensions are in mm. 0.65 7.00 6.75 0.85 0.2 0.00/0.05 44 1 2 3 6.75 7.00 TOP VIEW 12 SEATING PLANE 7.00 0.42 0.24/0.60 4.95/5.25 SIDE VIEW PIN#1 ID R0.20 5.10 44 0.00/0.05 1 0.45 0.23 0.18/0.30 2 3 0.42 0.24/0.60 SECTION "C-C" 5.10 SCALE: NONE 5.00 7.00 4.95/5.25 C C CL 5.00 0.50 TERMINAL TIP FOR ODD TERMINAL/SIDE BOTTOM VIEW Figure 47: 73S1210F 44 QFN Package Drawing Rev. 1.4 123 73S1210F Data Sheet DS_1210F_001 7 Ordering Information Table 109 lists the order numbers and packaging marks used to identify 73S1210F products. Table 109: Order Numbers and Packaging Marks Part Description Order Number Packaging Mark 73S1210F 68-Pin QFN, Lead Free 73S1210F 68-Pin QFN, Lead Free with Programming 73S1210F-68IM/F 73S1210F-68IM/F/P 73S1210F68IM 73S1210F68IM 73S1210F 68-Pin QFN, Lead Free, Tape and Reel 73S1210F-68IMR/F 73S1210F 68-Pin QFN, Lead Free, Tape and Reel with Programming 73S1210F-68IMR/F/P 73S1210F68IM 73S1210F68IM 73S1210F 44-Pin QFN, Lead Free 73S1210F 44-Pin QFN, Lead Free with Programming 73S1210F44IM 73S1210F44IM 73S1210F-44IM/F 73S1210F-44IM/F/P 73S1210F 44-Pin QFN, Lead Free, Tape and Reel 73S1210F-44IMR/F 73S1210F 44-Pin QFN, Lead Free, Tape and Reel with Programming 73S1210F-44IMR/F/P 73S1210F44IM 73S1210F44IM 8 Related Documentation The following 73S1210F documents are available from Teridian Semiconductor Corporation: 73S1210F Data Sheet (this document) 73S1210F Development Board Quick Start Guide 73S1210F Software Development Kit Quick Start Guide 73S1210F Evaluation Board User's Guide 73S12xxF Software User's Guide 73S12xxF Synchronous Card Design Application Note 9 Contact Information For more information about Teridian Semiconductor products or to check the availability of the 73S1210F, contact us at: 6440 Oak Canyon Road Suite 100 Irvine, CA 92618-5201 Telephone: (714) 508-8800 FAX: (714) 508-8878 Email: scr.support@teridian.com For a complete list of worldwide sales offices, go to http://www.teridian.com. 124 Rev. 1.4 DS_1210F_001 73S1210F Data Sheet Revision History Revision Date 1.0 1.1 5/10/2007 11/6/2007 Description First publication. In Table 1, added Equivalent Circuit references. In Section 1.4, updated program security description to remove pre-boot and 32-cycle references. In Section 1.7.1, changed "Mcount is configured in the MCLKCtl register must be bound between a value of 1 to 7. The possible crystal or external clock are shown in Table 12." to "Mcount is configured in the MCLKCtl register must be bound between a value of 1 to 7. The possible crystal or external clock frequencies for getting MCLK = 96MHz are shown in Table 11." In the BRCON description, changed "If BSEL = 1, the baud rate is derived using timer 1." to "If BSEL = 0, the baud rate is derived using timer 1." 1.2 12/15/2008 In Section 1.7.14, removed the following from the emulator port description: "The signals of the emulator port have weak pull-ups. Adding resistor footprints for signals E_RST, E_TCLK and E_RXTX on the PCB is recommended. If necessary, adding 10K pull-up resistors on E_TCLK and E_RXTX and a 3K on E_RST will help the emulator operate normally if a problem arises." In Ordering Information, removed the leaded part numbers. In Table 1, added the "Pin (44 QFN)" column. In Table 1, added more description to the SCL, SDA, PRES, VCC, VPC, SEC, TEST and VDD pins. In Section 1.3.2, changed "FLSH_ERASE" to "ERASE" and "FLSH_PGADR" to "PGADDR". Added "The PGADDR register denotes the page address for page erase. The page size is 512 (200h) bytes and there are 128 pages within the flash memory. The PGADDR denotes the upper seven bits of the flash memory address such that bit 7:1 of the PGADDR corresponds to bit 15:9 of the flash memory address. Bit 0 of the PGADDR is not used and is ignored." In the description of the PGADDR register, added "Note: the page address is shifted left by one bit (see detailed description above)." In Table 5, changed "FLSHCRL" to "FLSHCTL". In Table 5, removed the PREBOOT bit description. In Table 5, moved the TRIMPCtl bit description to FUSECtl and moved the FUSECtl bit description to TRIMPCtl. In Table 6, changed "PGADR" to "PGADDR". In Table 7, added PGADDR. In Table 8, changed the reset value for RTCCtl from "0x81" to "0x00". Added the RTCTrim0 and ACOMP registers. Deleted the OMP, VRCtl, LEDCal and LOCKCtl registers. In Table 7, removed the Mcount 7 row. In Table 50 through Table 53, changed the names of registers USRIntCtl0 through USRIntCtl3 to USRIntCtl1 through USRIntCtl4. In TCON, corrected the descriptions for TCON.2 and TCON.0. In Section 1.7.9, added a note about USR pins defaulting as inputs after reset. Changed the register address for ATRMsB from FE21 to FE1F. Rev. 1.4 125 73S1210F Data Sheet DS_1210F_001 In Section 1.7.15.5, deleted "The ETU clock is held in reset condition until the activation sequence begins (either by VCCOK=1 or VCCTMR timeout) and will go high 1/2 the ETU period thereafter." In Section 1.7.15.5, added "Synchronous card operation is broken down into three primary types. These are commonly referred to as 2-wire, 3-wire and I2C synchronous cards. Each card type requires different control and timing and therefore requires different algorithms to access. Teridian has created an application note to provide detailed algorithms for each card type. Refer to the application note titled 73S12xxF Synchronous Card Design Application Note." In Table 78 and Table 107, changed the SYCKST bit to I2CMODE. In Figure 25, replaced the schematic with a new schematic. In Section 3.4, changed the Fxtal Min from 4 to 6. Added 44-pin QFN package. Added Section 8, Related Documentation. Added Section 9, Contact Information. Formatted the document per new standard. Added section numbering. 1.3 1/22/2009 Changed the value for the IDD_IN Power Down (25C) parameter from 13 A to 15 A. 1.4 5/12/2009 In Table 1, corrected the 44 QFN GND pin from 37 to 26. Added the "with Programming" ordering numbers to Table 109. (c) 2009 Teridian Semiconductor Corporation. All rights reserved. Teridian Semiconductor Corporation is a registered trademark of Teridian Semiconductor Corporation. Windows is a registered trademark of Microsoft Corporation. Signum Systems is a trademark of Signum Systems Corporation. All other trademarks are the property of their respective owners. Teridian Semiconductor Corporation makes no warranty for the use of its products, other than expressly contained in the Company's warranty detailed in the Teridian Semiconductor Corporation standard Terms and Conditions. The company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice and does not make any commitment to update the information contained herein. Accordingly, the reader is cautioned to verify that this document is current by comparing it to the latest version on http://www.teridian.com or by checking with your sales representative. Teridian Semiconductor Corp., 6440 Oak Canyon, Suite 100, Irvine, CA 92618 TEL (714) 508-8800, FAX (714) 508-8877, http://www.teridian.com 126 Rev. 1.4 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Maxim Integrated: 73S1210F-44IM/F 73S1210F-44IMR/F 73S1210F-68IM/F 73S1210F-68IMR/F 73S1210F-44M/F/PC 73S1210F44MR/F/PC 73S1210F-68M/F/PG 73S1210F-68M/F/PH 73S1210F-68MR/F/PG 73S1210F-68MR/F/PH 73S1210F44IMR/F/P 73S1210F-44IM/F/P 73S1210F-IM68 DK 73S1210F-IM68 EB 73S1210F-68MR/F/PJ 73S1210F-68M/F/PJ