SCD SPECIFICATION CONTROL DRAWING 55A0811 Date Revision WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, 4-27-15 NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 55A. Title Z PRIMARY INSULATION - RADIATION-CROSSLINKED, MODIFIED ETFE Primary insulation shall be of a contrasting pigmentation to that of the jacket. CONDUCTOR - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS PART NUMBER 1/ WIRE SIZE (AWG) CONDUCTOR STRANDING (number x AWG) DIAMETER OF STRANDED CONDUCTOR (inch) FINISHED WIRE MAXIMUM RESISTANCE AT 20C (ohms/1000 ft.) DIAMETER (inch) MAXIMUM WEIGHT (lbs/1000 ft.) MINIMUM MAXIMUM 55A0811-28-* 28 7 x 36 .014 .016 68.6 .035 .002 1.3 55A0811-26-* 26 19 x 38 .018 .020 41.3 .040 .002 1.7 55A0811-24-* 24 19 x 36 .023 .025 26.2 .045 .002 2.3 55A0811-22-* 22 19 x 34 .029 .031 16.2 .050 .002 3.2 55A0811-20-* 20 19 x 32 .037 .039 9.88 .058 .002 4.7 55A0811-18-* 18 19 x 30 .046 .049 6.23 .070 .003 7.2 55A0811-16-* 16 19 x 29 .052 .055 4.81 .077 .003 9.0 55A0811-14-* 14 19 x 27 .065 .069 3.06 .094 .003 13.8 55A0811-12-* 12 37 x 28 .084 .089 2.02 .111 .003 20.5 55A0811-10-* 10 37 x 26 .106 .113 1.26 .134 .004 32.4 55A0811-8-* 8 133 x 29 .158 .173 .701 .195 .008 60.3 55A0811-6-* 6 133 x 27 .198 .217 .445 .241 .010 55A0811-4-* 4 133 x 25 .250 .274 .280 .310 .010 150. 55A0811-2-* 2 665 x 30 .320 .340 .183 .408 .012 249. 55A0811-1-* 1 817 x 30 .360 .380 .149 .470 .012 325. 55A0811-0-* 0 1045 x 30 .395 .425 .116 .510 .016 383. 94.5 55A0811-00-* 00 1330 x 30 .440 .475 .091 .570 .016 500. 55A0811-000-* 000 1665 x 30 .500 .540 .071 .610 .016 596. 55A0811-0000-* 0000 2109 x 30 .565 .605 .056 .675 .022 753. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE Connectivity (logo), and TE (logo) are trademarks. Page 1 of 2 DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2008-2015 Tyco Electronics Corporation. All rights reserved. Page SPECIFICATION CONTROL DRAWING Revision 2 of 2 SCD 55A0811 Z TABLE II. PERFORMANCE DETAILS PART NUMBER 1/ MANDREL DIAMETER (inch) ( 3%) LIFE CYCLE, IMMERSION, AND ACCELERATED AGING WEIGHT (lb) ( 3%) COLD BEND LIFE CYCLE, IMMERSION, AND ACCELERATED AGING .750 COLD BEND 55A0811-28-* .375 .250 2.00 55A0811-26-* .375 1.00 .500 3.00 55A0811-24-* .500 1.00 .750 55A0811-22-* .500 1.00 1.00 3.00 55A0811-20-* .500 1.00 1.50 4.00 55A0811-18-* .750 1.50 2.00 4.00 3.00 55A0811-16-* 1.00 1.50 2.00 5.00 55A0811-14-* 1.00 2.00 3.00 5.00 55A0811-12-* 1.50 2.00 3.00 5.00 55A0811-10-* 2.00 3.00 3.00 5.00 55A0811-8-* 3.00 4.00 4.00 6.00 55A0811-6-* 4.00 5.00 4.00 10.0 55A0811-4-* 5.00 6.00 4.00 10.0 55A0811-2-* 6.00 8.00 6.00 15.0 55A0811-1-* 8.00 10.0 6.00 15.0 55A0811-0-* 8.00 10.0 6.00 15.0 55A0811-00-* 10.0 12.0 8.00 20.0 55A0811-000-* 10.0 12.0 8.00 20.0 55A0811-0000-* 10.0 12.0 8.00 20.0 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING (CROSSLINKING PROOF): 300 3C for 7 hours BLOCKING: 200 3C for 24 hours COLOR: White preferred CONCENTRICITY: 70% (minimum) FLAMMABILITY: Procedure 1, 3 seconds (maximum), 3 inches (maximum); no flaming of facial tissue HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft. (minimum), AWG 28-10 3000 megohms for 1000 ft. (minimum), AWG 8-0000 IDENTIFICATION, COLOR STRIPING, AND BAND DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: Elongation, 125% (minimum) for primary insulation, AWG 28-10 only 75% (minimum) for total insulation (primary insulation & jacket) Tensile Strength, 5000 lbf/in2 (minimum) for primary insulation 5000 lbf/in2 (minimum) for total insulation (primary insulation & jacket) INSULATION FLAWS: Primary Insulation, Spark Test, 1.5 kV (rms) at 60 Hz; 4.2 kV (rms) at 3 kHz Impulse Dielectric Test, 6.0 kV (peak) Finished Wire, Spark Test, 5.7 kV (rms) at 3 kHz Impulse Dielectric Test, 8.0 kV (peak) 1/ See footer section on page 1 INSULATION RESISTANCE: 5000 megohms for 1000 ft. (minimum), AWG 28-10 3000 megohms for 1000 ft. (minimum), AWG 8-0000 INSULATION THICKNESS: 0.003 in. (minimum) for primary insulation 0.004 in. (minimum) for outer jacket 0.009 in. (minimum) for total insulation LIFE CYCLE: 200 3C for 500 hours LOW TEMPERATURE-COLD BEND: -65 3C for 4 hours SHRINKAGE: 200 3C for 6 hours, 0.125 in. (maximum) in 12 inches SMOKE TEST: 200 2C, no visible smoke SOLDERABILITY (AWG 10 and smaller only): Per MIL-STD-202, Method 208, except without steam aging SURFACE RESISTANCE: 500 meghoms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 150 3C, 0.060 in. (maximum), AWG 28-12 0.100 in. (maximum), AWG 10-8 0.125 in. (maximum), AWG 6-0000 VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz WICKING: 2.25 in. (maximum) WRAP TEST: 200 3C for 2 hours 1/ PART NUMBER: The "*" in the part numbers in Tables I and II shall be replaced by a color code designator. Example: AWG 22, white: 55A0811-22-9 AWG 22, white with a black stripe: 55A0811-22-90 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: 55A0811-6-9