HM 65688A MATRA MHS
Rev. C (12/12/94)4
DC Parameters
PARAMETER DESCRIPTION MINIMUM TYPICAL MAXIMUM UNIT
IIX (3) Input leakage current – 1.0 – 1.0 µA
IOZ (3) Output leakage current – 1.0 – 1.0 µA
VOL (4) Output low voltage – – 0.4 V
VOH (4) Output high voltage 2.4 – – V
Note : 3. Gnd < Vin < Vcc, Gnd < Vout < Vcc output disabled, CS ≥ 2.2 V.
4. Vcc min, IOL = 4.0 mA, IOH = –1.0 mA.
Consumption for Commercial Specification (–5) :
SYMBOL PARAMETER 6568A B-5 65688A S-5 65688A -5 65688A C-5 UNIT VALUE
ICCSB (5) Standby supply current 10 15 10 15 mA max
ICCSB1 (6) Standby supply current 1.0 75 1.0 75 µA max
ICCOP (7) Operating supply current 65 75 65 75 mA max
Consumption for Industrial Specification (–9) :
SYMBOL PARAMETER 65688A B-9 65688A S-9 65688A -9 65688A C-9 UNIT VALUE
ICCSB (5) Standby supply current 15 20 15 20 mA max
ICCSB1 (6) Standby supply current 5.0 100.0 5.0 100.0 µA max
ICCOP (7) Operating supply current 75 100 75 100 mA max
Consumption for Military Specification (–2) :
SYMBOL PARAMETER 65688A B-2 65688A S-2 65688A -2 65688A C-2 UNIT VALUE
ICCSB (5) Standby supply current 15 20 15 20 mA max
ICCSB1 (6) Standby supply current 50.0 500.0 50.0 500.0 µA max
ICCOP (7) Operating supply current 75 100 75 100 mA max
Notes : 5. CS ≥ VIH.
6. CS ≥ Vcc – 0.3 V, Iout = 0 mA.
7. Vcc max, Iout = 0 mA, f = max, Vin = Gnd/Vcc.
Output Load