www.vishay.com For technical questions, contact: ww2aresistors@vishay.com Document Number: 30113
44 Revision: 10-Jan-11
CP High Volume
Vishay Dale
Wirewound/Metal Oxide Resistors, Commercial Power, Axial Lead
FEATURES
High performance for low cost
High power to size ratio
Ceramic cases are available with circuit board
stand-offs (designated with a ...3 model ending)
Special cement potting compound and ceramic
case provide high thermal conductivity in a
fireproof package
Compliant to RoHS Directive 2002/95/EC
STANDARD ELECTRICAL SPECIFICATIONS
GLOBAL MODEL
POWER RATING
P40 °C
W
RESISTANCE RANGE Ω
WIREWOUND
RESISTANCE RANGE Ω
METAL OXIDE
TOLERANCE
± %
WEIGHT
(typical)
g
CP0002 2 0.1 to 100 101 to 30K 5, 10 2.0
CP0003 3 0.1 to 100 101 to 33K 5, 10 3.4
CP0005 5 0.1 to 100 101 to 50K 5, 10 3.6
CP0005...3 5 0.1 to 100 101 to 50K 5, 10 4.8
CP0007 7 0.1 to 100 101 to 50K 5, 10 5.0
CP0007...3 7 0.1 to 100 101 to 50K 5, 10 6.8
CP0010 10 0.1 to 100 101 to 50K 5, 10 9.5
CP0010...3 10 0.1 to 100 101 to 50K 5, 10 9.9
CP0015 15 0.1 to 100 101 to 50K 5, 10 16.8
CP0020 20 0.1 to 100 101 to 50K 5, 10 22.8
TECHNICAL SPECIFICATIONS
PARAMETER UNIT WIREWOUND CHARACTERISTICS METAL OXIDE CHARACTERISTICS
Temperature Coefficient ppm/°C ± 400 ± 400
Short Time Overload - 5 x rated power for 5 s 5 x rated power for 5 s
Terminal Strength lb 10 minimum 10 minimum
Operating Temperature Range °C - 65 to + 275 - 65 to + 225
Dielectric Withstanding Voltage VAC 1000 1000
Maximum Working Voltage V (P x R)1/2 (P x R)1/2
GLOBAL PART NUMBER INFORMATION
Global Part Numbering example: CP000515R00JE663
GLOBAL MODEL VALUE TOLERANCE PACKAGING SPECIAL
(See Standard Electrical
Specifications Global
Model column for
options)
R = Decimal
K = Thousand
R1500 = 0.15 Ω
1K500 = 1500 Ω
J = ± 5.0 %
K = ± 10.0 %
E66 = Lead (Pb)-free bulk pack (Dash Number)
(up to 3 digits)
From 1 to 999
as applicable
** Please see document “Vishay Material Category Policy”: www.vishay.com/doc?99902
P000515R00JE66C 3
Document Number: 30113 For technical questions, contact: ww2aresistors@vishay.com www.vishay.com
Revision: 10-Jan-11 45
CP High Volume
Wirewound/Metal Oxide Resistors,
Commercial Power, Axial Lead Vishay Dale
DIMENSIONS in inches [millimeters]
Notes
(1) Potting compound may extend outside of ceramic case up to 0.060 [1.52] maximum per side.
MATERIAL SPECIFICATIONS
Element: Wirewound = Copper-nickel alloy or nickel-
chrome alloy, depending on resistance value
Metal Oxide = High temperature fired metal oxide film
Core: Wirewound = Woven fiberglass
Metal Oxide = Ceramic
Body: Steatite ceramic case with inorganic potting
compound
End Caps: Tin plated steel
Terminals: Tinned copper
Part Marking: DALE, model, wattage, value, tolerance, date
code
DERATING
GLOBAL MODEL
DIMENSIONS in inches [millimeters]
L (1)
± 0.060 [1.5]
W
± 0.040 [1.0]
H
± 0.040 [1.0]
H1
± 0.060 [1.5]
LD
± 0.002 [0.05]
LL
± 0.120 [3.0]
CP0002 0.71 [18] 0.276 [7] 0.276 [7] - 0.0256 [0.65] 1.378 [35]
CP0003 0.87 [22] 0.315 [8] 0.315 [8] - 0.031 [0.8] 1.378 [35]
CP0005 0.87 [22] 0.394 [10] 0.354 [9] - 0.031 [0.8] 1.378 [35]
CP0005...3 0.87 [22] 0.394 [10] 0.354 [9] 0.413 [10.5] 0.031 [0.8] 1.378 [35]
CP0007 1.38 [35] 0.394 [10] 0.354 [9] - 0.031 [0.8] 1.378 [35]
CP0007...3 1.38 [35] 0.394 [10] 0.354 [9] 0.472 [12] 0.031 [0.8] 1.378 [35]
CP0010 1.89 [48] 0.394 [10] 0.354 [9] - 0.031 [0.8] 1.378 [35]
CP0010...3 1.89 [48] 0.394 [10] 0.354 [9] 0.472 [12] 0.031 [0.8] 1.378 [35]
CP0015 1.89 [48] 0.492 [12.5] 0.453 [11.5] - 0.031 [0.8] 1.378 [35]
CP0020 2.36 [60] 0.551 [14] 0.531 [13.5] - 0.031 [0.8] 1.378 [35]
CPxxxx
LL L LD W
H
CPxxxx...3
LL L
LD W
H
H1
3.18 [0.125]
typical
RATED POWER IN %
AMBIENT TEMPERATURE IN °C
0
20
40
60
80
100
120
- 55 75 275- 25 175 225
125
25
40
Wirewound
Metal Oxide
PERFORMANCE
TEST CONDITIONS OF TEST TEST LIMITS (EIA-344)
Thermal Shock - 55 °C to + 275 °C (+ 225 °C for Metal Oxide), 5 cycles, 30 min dwell time ± (5.0 % + 0.05 Ω) ΔR
Short Time Overload 5 x rated power for 5 s ± (4.0 % + 0.05 Ω) ΔR
Dielectric Withstanding Voltage 1000 VRMS, for 1 min ± (2.0 % + 0.05 Ω) ΔR
Low Temperature Storage - 65 °C, full rated working voltage for 45 min ± (3.0 % + 0.05 Ω) ΔR
Humidity 75 °C, 90 % to 100 % RH, 240 h ± (5.0 % + 0.05 Ω) ΔR
Load Life 1000 h at rated power, + 25 °C, 1.5 h “ON”, 0.5 h “OFF” ± (10.0 % + 0.05 Ω) ΔR
Terminal Strength 5 pounds for 30 s; body twisted about axis, 3 x 360° rotations ± (2.0 % + 0.05 Ω) ΔR
Resistance to Solder Heat Terminal immersed 3.5 s in molten solder at 1/8" to 3/16" from body ± (4.0 % + 0.05 Ω) ΔR
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 12-Mar-12 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.