Intel Advanced Boot Block Flash Memory (B3) 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Datasheet Product Features * Flexible SmartVoltage Technology -- 2.7 V-3.6 V Read/Program/Erase -- 12 V VPP Fast Production Programming * 1.65 V-2.5 V or 2.7 V-3.6 V I/O Option -- Reduces Overall System Power * High Performance -- 2.7 V-3.6 V: 70 ns Max Access Time * Optimized Block Sizes -- Eight 8-KB Blocks for Data,Top or Bottom Locations -- Up to One Hundred Twenty-Seven 64KB Blocks for Code * Block Locking -- VCC-Level Control through WP# * Low Power Consumption -- 9 mA Typical Read Current * Absolute Hardware-Protection -- VPP = GND Option -- VCC Lockout Voltage * Extended Temperature Operation -- -40 C to +85 C * Automated Program and Block Erase -- Status Registers * Intel(R) Flash Data Integrator Software -- Flash Memory Manager -- System Interrupt Manager -- Supports Parameter Storage, Streaming Data (e.g., Voice) * Extended Cycling Capability -- Minimum 100,000 Block Erase Cycles Guaranteed * Automatic Power Savings Feature -- Typical ICCS after Bus Inactivity * Standard Surface Mount Packaging -- 48-Ball CSP Packages -- 40- and 48-Lead TSOP Packages * Density and Footprint Upgradeable for common package -- 8-, 16-, 32- and 64-Mbit Densities * ETOXTM VIII (0.13 m) Flash Technology -- 16 and 32-Mbit Densities * ETOXTM VII (0.18 m) Flash Technology -- 16-, 32- and 64-Mbit Densities * ETOX TM VI (0.25m) Flash Technology -- 8-, 16-, and 32-Mbit Densities * The x8 option not recommended for new designs The Intel(R) Advanced Boot Block Flash Memory (B3) device, manufactured on Intel's latest 0.13 m and 0.18 m technologies, represents a feature-rich solution at overall lower system cost. The B3 device in x16 will be available in 48-lead TSOP and 48-ball CSP packages. The x8 option of this product family is available only in 40-lead TSOP and 48-ball BGA* packages. Additional information on this product family can be obtained by accessing Intel's website at: http://www.intel.com/design/flash. Notice: This specification is subject to change without notice. Verify with your local Intel sales office that you have the latest datasheet before finalizing a design. Order Number: 290580-017 May 2003 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an ordering number and are referenced in this document, or other Intel literature may be obtained by calling 1-800548-4725 or by visiting Intel's website at http://developer.intel.com/design/flash. Copyright (c) Intel Corporation 2003. *Other names and brands may be claimed as the property of others. 2 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Contents 1.0 Introduction ..................................................................................................................7 1.1 2.0 Product Description ..................................................................................................9 2.1 2.2 3.0 3.2 3.3 3.4 3.5 3.6 3.7 Bus Operation .....................................................................................................14 3.1.1 Read .......................................................................................................15 3.1.2 Output Disable........................................................................................15 3.1.3 Standby ..................................................................................................15 3.1.4 Deep Power-Down / Reset.....................................................................15 3.1.5 Write .......................................................................................................16 Modes of Operation.............................................................................................16 3.2.1 Read Array .............................................................................................16 3.2.2 Read Identifier ........................................................................................17 3.2.3 Read Status Register .............................................................................18 3.2.3.1 Clearing the Status Register .....................................................18 3.2.4 Program Mode........................................................................................19 3.2.4.1 Suspending and Resuming Program ........................................19 3.2.5 Erase Mode ............................................................................................19 3.2.5.1 Suspending and Resuming Erase .............................................20 Block Locking ......................................................................................................21 3.3.1 WP# = VIL for Block Locking ..................................................................21 3.3.2 WP# = VIH for Block Unlocking ..............................................................22 VPP Program and Erase Voltages .......................................................................22 3.4.1 VPP = VIL for Complete Protection .........................................................22 Power Consumption ............................................................................................22 3.5.1 Active Power ..........................................................................................23 3.5.2 Automatic Power Savings (APS) ............................................................23 3.5.3 Standby Power .......................................................................................23 3.5.4 Deep Power-Down Mode .......................................................................23 Power and Reset Considerations........................................................................23 3.6.1 Power-Up/Down Characteristics ............................................................23 3.6.2 RP# Connected to System Reset...........................................................24 3.6.3 VCC, VPP and RP# Transitions ...............................................................24 Power Supply Decoupling ...................................................................................24 Thermal and DC Characteristics ........................................................................25 4.1 4.2 4.3 4.4 Datasheet Package Pinouts ...................................................................................................9 Block Organization ..............................................................................................13 2.2.1 Parameter Blocks ...................................................................................14 2.2.2 Main Blocks ............................................................................................14 Principles of Operation ..........................................................................................14 3.1 4.0 Product Overview ..................................................................................................8 Absolute Maximum Ratings.................................................................................25 Operating Conditions...........................................................................................26 DC Current Characteristics .................................................................................26 DC Voltage Characteristics .................................................................................29 3 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 5.0 AC Characteristics................................................................................................... 30 5.1 5.2 5.3 5.4 5.5 5.6 AC Read Characteristics..................................................................................... 30 AC Write Characteristics ..................................................................................... 34 Erase and Program Timings ............................................................................... 38 Reset Specifications............................................................................................ 39 AC I/O Test Conditions ....................................................................................... 40 Device Capacitance ............................................................................................ 40 6.0 Reset Operations ..................................................................................................... 41 7.0 Ordering Information .............................................................................................. 42 8.0 Additional Information ........................................................................................... 44 Appendix A Write State Machine Current/Next States ................................................. 45 Appendix B Architecture Block Diagram ........................................................................... 46 Appendix C Word-Wide Memory Map Diagrams............................................................. 47 Appendix D Byte-Wide Memory Map Diagrams .............................................................. 53 Appendix E Program and Erase Flowcharts .................................................................... 56 Appendix F Mechanical Specifications .............................................................................. 60 4 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Revision History Number Datasheet Description -001 Original version -002 Section 3.4, VPP Program and Erase Voltages, added Updated Figure 9: Automated Block Erase Flowchart Updated Figure 10: Erase Suspend/Resume Flowchart (added program to table) Updated Figure 16: AC Waveform: Program and Erase Operations (updated notes) IPPR maximum specification change from 25 A to 50 A Program and Erase Suspend Latency specification change Updated Appendix A: Ordering Information (included 8 M and 4 M information) Updated Figure, Appendix D: Architecture Block Diagram (Block info. in words not bytes) Minor wording changes -003 Combined byte-wide specification (previously 290605) with this document Improved speed specification to 80 ns (3.0 V) and 90 ns (2.7 V) Improved 1.8 V I/O option to minimum 1.65 V (Section 3.4) Improved several DC characteristics (Section 4.4) Improved several AC characteristics (Sections 4.5 and 4.6) Combined 2.7 V and 1.8 V DC characteristics (Section 4.4) Added 5 V VPP read specification (Section 3.4) Removed 120 ns and 150 ns speed offerings Moved Ordering Information from Appendix to Section 6.0; updated information Moved Additional Information from Appendix to Section 7.0 Updated figure Appendix B, Access Time vs. Capacitive Load Updated figure Appendix C, Architecture Block Diagram Moved Program and Erase Flowcharts to Appendix E Updated Program Flowchart Updated Program Suspend/Resume Flowchart Minor text edits throughout -004 Added 32-Mbit density Added 98H as a reserved command (Table 4) A1-A20 = 0 when in read identifier mode (Section 3.2.2) Status register clarification for SR3 (Table 7) VCC and VCCQ absolute maximum specification = 3.7 V (Section 4.1) Combined IPPW and ICCW into one specification (Section 4.4) Combined IPPE and ICCE into one specification (Section 4.4) Max Parameter Block Erase Time (tWHQV2/tEHQV2) reduced to 4 sec (Section 4.7) Max Main Block Erase Time (tWHQV3/tEHQV3) reduced to 5 sec (Section 4.7) Erase suspend time @ 12 V (tWHRH2/tEHRH2) changed to 5 s typical and 20 s maximum (Section 4.7) Ordering Information updated (Section 6.0) Write State Machine Current/Next States Table updated (Appendix A) Program Suspend/Resume Flowchart updated (Appendix F) Erase Suspend/Resume Flowchart updated (Appendix F) Text clarifications throughout -005 BGA package diagrams corrected (Figures 3 and 4) IPPD test conditions corrected (Section 4.4) 32-Mbit ordering information corrected (Section 6) BGA package top side mark information added (Section 6) -006 VIH and VILSpecification change (Section 4.4) ICCS test conditions clarification (Section 4.4) Added Command Sequence Error Note (Table 7) Data sheet renamed from Smart 3 Advanced Boot Block 4-Mbit, 8-Mbit, 16-Mbit Flash Memory Family. Added device ID information for 4-Mbit x8 device Removed 32-Mbit x8 to reflect product offerings Minor text changes -007 Corrected RP# pin description in Table 2, 3 Volt Advanced Boot Block Pin Descriptions Corrected typographical error fixed in Ordering Information 5 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Number Description -008 4-Mbit packaging and addressing information corrected throughout document -009 Corrected 4-Mbit memory addressing tables in Appendices D and E -010 Max ICCD changed to 25 A VCCMax on 32 M (28F320B3) changed to 3.3 V -011 Added 64-Mbit density and faster speed offerings Removed access time vs. capacitance load curve -012 Changed references of 32Mbit 80ns devices to 70ns devices to reflect the faster product offering. Changed VccMax=3.3V reference to indicate the affected product is the 0.25m 32Mbit device. Minor text edits throughout document. -013 Added New Pin-1 indicator information on 40 and 48Lead TSOP packages. Minor text edits throughout document. -014 Added specifications for 0.13 micron product offerings throughout document -015 Minor text edits throughout document. Adjusted ordering information. Adjusted specifications for 0.13 micron product offerings. -016 Revised and corrected DC Characteristics Table. Adjusted package diagram information. Minor text edits throughout document. Updated ordering information. Adjusted specifications for 0.13 micron product offerings. -017 Updated AC/DC Characteristics Table. Added TSOP and BGA* package diagram information. Minor text edits throughout document. 6 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 1.0 Introduction This datasheet contains the specifications for the Intel Advanced Boot Block Flash Memory (B3) device, which is optimized for portable, low-power, systems. This family of products features 1.65 V-2.5 V or 2.7 V-3.6 V I/Os, and a low VCC/VPP operating range of 2.7 V-3.6 V for Read, Program, and Erase operations. In addition, this family is capable of fast programming at 12 V. Throughout this document, the term "2.7 V" refers to the full voltage range 2.7 V-3.6 V (except where noted otherwise) and "VPP = 12 V" refers to 12 V 5%. Section 1.0 and 2.0 provide an overview of the B3 device, including applications, pinouts, and pin descriptions. Section 3.0 describes the memory organization and operation. Sections 4.0 and 5.0 contain the operating specifications. Finally, Sections 6.0 and 7.0 provide ordering and other reference information. The B3 device features the following: * Enhanced blocking for easy segmentation of code and data or additional design flexibility * Program Suspend to Read command * VCCQ input of 1.65 V-2.5 V or 2.7 V-3.6 V on all I/Os. See Figures 1 through 4 for pinout diagrams and VCCQ location * Maximum program and erase time specification for improved data storage. Table 1. B3 Device Feature Summary Feature VCC Read Voltage VCCQ I/O Voltage Speed Reference Section 4.2, Section 4.4 2.7 V- 3.6 V VPP Program/Erase Voltage Bus Width 28F800B3, 28F160B3, 28F320B3(3), 28F640B3 28F008B3, 28F016B3 1.65 V-2.5 V or 2.7 V- 3.6 V Section 4.2, 4.4 2.7 V- 3.6 V or 11.4 V- 12.6 V Section 4.2, 4.4 8 bit 16 bit 70 ns, 80 ns, 90 ns, 100 ns, 110 ns 512 Kbit x 16 (8 Mbit), 1024 Kbit x 16 (16 Mbit), 2048 Kbit x 16 (32 Mbit), 4096 Kbit x 16 (64 Mbit) Table 3 Section 5.1 Memory Arrangement 1024 Kbit x 8 (8 Mbit), 2048 Kbit x 8 (16 Mbit) Blocking (top or bottom) Eight 8-Kbyte parameter blocks and Fifteen 64-Kbyte blocks (8 Mbit) or Thirty-one 64-Kbyte main blocks (16 Mbit) Sixty-three 64-Kbyte main blocks (32 Mbit) One hundred twenty-seven 64-Kbyte main blocks (64 Mbit) Section 2.2 Appendix C WP# locks/unlocks parameter blocks All other blocks protected using VPP Section 3.3 Table 8 Operating Temperature Extended: -40 C to +85 C Section 4.2, Section 4.4 Program/Erase Cycling 100,000 cycles Section 4.2, Section 4.4 Locking Packages 40-lead TSOP(1), 48-Ball BGA* CSP(2) 48-Lead TSOP, 48-Ball BGA CSP(2), 48-Ball VF BGA Section 2.2 Figure 4, Figure 5 NOTES: 1. 32-Mbit and 64-Mbit densities not available in 40-lead TSOP. 2. 8-Mbit densities not available in BGA* CSP. 3. VCCMax is 3.3 V on 0.25m 32-Mbit devices. Datasheet 7 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 1.1 Product Overview Intel provides the most flexible voltage solution in the flash industry, providing three discrete voltage supply pins: VCC for Read operation, VCCQ for output swing, and VPP for Program and Erase operation. All B3 products provide program/erase capability at 2.7 V or 12 V (for fast production programming), and read with VCC at 2.7 V. Since many designs read from the flash memory a large percentage of the time, 2.7 V VCC operation can provide substantial power savings. The B3 products are available in either x8 or x16 packages in the following densities: (see Section 7.0, "Ordering Information" on page 42 for availability.) * 8-Mbit (8, 388, 608-bit) flash memory organized as 512 Kwords of 16 bits each or 1024 Kbytes of 8-bits each * 16-Mbit (16, 777, 216-bit) flash memory organized as 1024 Kwords of 16 bits each or 2048 Kbytes of 8-bits each * 32-Mbit (33, 554, 432-bit) flash memory organized as 2048 Kwords of 16 bits each * 64-Mbit (67, 108, 864-bit) flash memory organized as 4096 Kwords of 16 bits each The parameter blocks are located at either the top (denoted by -T suffix) or the bottom (-B suffix) of the address map in order to accommodate different microprocessor protocols for kernel code location. The upper two (or lower two) parameter blocks can be locked to provide complete code security for system initialization code. Locking and unlocking is controlled by WP# (see Section 3.3, "Block Locking" on page 21 for details). The Command User Interface (CUI) serves as the interface between the microprocessor or microcontroller and the internal operation of the flash memory. The internal Write State Machine (WSM) automatically executes the algorithms and timings necessary for Program and Erase operations, including verification, thereby unburdening the microprocessor or microcontroller. The status register indicates the status of the WSM by signifying block erase or word program completion and status. The B3 flash memory device is also designed with an Automatic Power Savings (APS) feature, which minimizes system current drain and allows for very low power designs. This mode is entered following the completion of a read cycle (approximately 300 ns later). The RP# pin provides additional protection against unwanted command writes that may occur during system reset and power-up/down sequences due to invalid system bus conditions (see Section 3.6, "Power and Reset Considerations" on page 23). Section 3.0, "Principles of Operation" on page 14 gives detailed explanation of the different modes of operation. Section 4.0, "Thermal and DC Characteristics" on page 25 provides complete current and voltage specifications. Refer to Section 5.1, "AC Read Characteristics" on page 30 for read, program, and erase performance specifications. 8 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 2.0 Product Description This section explains device pin description and package pinouts. 2.1 Package Pinouts The B3 flash memory device is available in 40-lead TSOP (x8, Figure 1), 48-lead TSOP (x16, Figure 2), 48-ball BGA(x8 and x16, Figure 4 and Figure 5, respectively), and 48-ball VF BGA (x16, Figure 5) packages. Figure 1. 40-Lead TSOP Package for x8 Configurations 4M A16 A15 A14 A13 A12 A11 A9 A8 WE# RP# VPP WP# A18 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Advanced Boot Block 40-Lead TSOP 10 mm x 20 mm TOP VIEW 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 A17 GND A20 A19 A10 DQ7 DQ6 DQ5 DQ4 VCCQ VCC NC DQ3 DQ2 DQ1 DQ0 OE# GND CE# A0 16 M 8M 0580_01 NOTES: 1. 40-Lead TSOP available for 8-Mbit and 16-Mbit densities only. 2. Lower densities have NC on the upper address pins. For example, an 8-Mbit device will have NC on Pin 38. Figure 2. 48-Lead TSOP Package for x16 Configurations 64 M 32 M 16 M A15 A14 A13 A12 A11 A10 A9 A8 A21 A20 WE# RP# VPP WP# A19 A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Advanced Boot Block 48-Lead TSOP 12 mm x 20 mm TOP VIEW 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A 16 V CCQ GND DQ15 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 V CC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# GND CE# A0 0580_02 Datasheet 9 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 3. New Mark for Pin-1 indicator for 40-Lead 8 Mb, 16 Mb TSOP and 48-Lead 8 Mb, 16 Mb and 32 Mb TSOP Current Mark: New Mark: Note: 10 The topside marking on 8 Mb, 16 Mb, and 32 Mb Intel Advanced Boot Block 40L and 48L TSOP products will convert to a white ink triangle as a Pin-1 indicator. Products without the white triangle will continue to use a dimple as a Pin-1 indicator. There are no other changes in package size, materials, functionality, customer handling, or manufacturability. Product will continue to meet stringent Intel quality requirements. The products affected are the following Intel Ordering Codes: Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Ordering Information Valid Combinations 40-Lead TSOP 48-Lead TSOP TE28F640B3TC70 Ext. Temp. 64 Mbit TE28F640B3BC70 TE28F320B3TD70 TE28F320B3BD70 TE28F320B3TC70 TE28F320B3BC70 TE28F320B3TC90 Ext. Temp. 32 Mbit TE28F320B3BC90 TE28F320B3TA100 TE28F320B3BA100 TE28F320B3TA110 TE28F320B3BA110 TE28F160B3TC70 TE28F160B3BC70 TE28F160B3TC80 Ext. Temp. 16 Mbit Ext. Temp. 8 Mbit TE28F160B3BC80 TE28F016B3TA90 TE28F160B3TA90 TE28F016B3BA90 TE28F160B3BA90 TE28F016B3TA110 TE28F160B3TA110 TE28F016B3BA110 TE28F160B3BA110 TE28F008B3TA90 TE28F800B3TA90 TE28F008B3BA90 TE28F800B3BA90 TE28F008B3TA110 TE28F800B3TA110 TE28F008B3BA110 TE28F800B3BA110 Figure 4. x8 48-Ball BGA* Chip Size Package (Top View, Ball Down) 1 2 3 4 5 6 7 8 16M A A14 A12 A8 V PP W P# A20 A7 A4 A19 A18 A5 A2 A6 A3 A1 8M B A15 A10 W E# C A16 A13 A9 D A17 NC D5 NC D2 NC CE# A0 E VCCQ A11 D6 NC D3 NC D0 GND D7 NC D4 VCC NC D1 OE# F GND RP# 0580_04 NOTES: 1. A19 and A20 indicate the upgrade address connections. Lower density devices will not have the upper address solder balls. Routing is not recommended in this area. A20 is the upgrade address for the 16-Mbit device. Datasheet 11 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 5. x16 48-Ball Very Fine Pitch BGA and BGA* Chip Size Package (Top View, Ball Down) 1 2 3 4 5 6 7 8 16M A A13 A11 A8 VPP WP# A19 A7 A4 B A14 A10 WE# RP# A18 A17 A5 A2 64M 32M C A15 A12 A9 A21 A20 A6 A3 A1 D A16 D14 D5 D11 D2 D8 CE# A0 E VCCQ D15 D6 D12 D3 D9 D0 Vss F Vss D7 D13 D4 VCC D10 D1 OE# 0580_03 NOTES: 1. A19, A20, and A21 indicate the upgrade address connections. Lower density devices will not have the upper address solder balls. Routing is not recommended in this area. A19 is the upgrade address for the 16-Mbit device. A20 is the upgrade address for the 32-Mbit device. A21 is the upgrade address for the 64-Mbit device. 2. Table 2, "B3 Device Pin Descriptions" on page 13 details the usage of each device pin. 12 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 2. Symbol B3 Device Pin Descriptions Type A0-A21 INPUT Name and Function ADDRESS INPUTS for memory addresses. Addresses are internally latched during a program or erase cycle. 28F008B3: A[0-19], 28F016B3: A[0-20], 28F800B3: A[0-18], 28F160B3: A[0-19], 28F320B3: A[0-20], 28F640B3: A[0-21] DQ0-DQ7 INPUT/ OUTPUT DATA INPUTS/OUTPUTS: Inputs array data on the second CE# and WE# cycle during a Program command. Inputs commands to the Command User Interface when CE# and WE# are active. Data is internally latched. Outputs array, identifier and status register data. The data pins float to tri-state when the chip is de-selected or the outputs are disabled. DQ8- DQ15 INPUT/ OUTPUT DATA INPUTS/OUTPUTS: Inputs array data on the second CE# and WE# cycle during a Program command. Data is internally latched. Outputs array and identifier data. The data pins float to tri-state when the chip is de-selected. Not included on x8 products. CE# INPUT CHIP ENABLE: Activates the internal control logic, input buffers, decoders and sense amplifiers. CE# is active low. CE# high de-selects the memory device and reduces power consumption to standby levels. OE# INPUT OUTPUT ENABLE: Enables the device's outputs through the data buffers during a Read operation. OE# is active low. WE# INPUT WRITE ENABLE: Controls writes to the Command Register and memory array. WE# is active low. Addresses and data are latched on the rising edge of the second WE# pulse. RESET/DEEP POWER-DOWN: Uses two voltage levels (VIL, VIH) to control reset/deep power-down mode. RP# INPUT When RP# is at logic low, the device is in reset/deep power-down mode, which drives the outputs to High-Z, resets the Write State Machine, and minimizes current levels (ICCD). When RP# is at logic high, the device is in standard operation. When RP# transitions from logiclow to logic-high, the device defaults to the read array mode. WRITE PROTECT: Provides a method for locking and unlocking the two lockable parameter blocks. WP# INPUT When WP# is at logic low, the lockable blocks are locked, preventing Program and Erase operations to those blocks. If a Program or Erase operation is attempted on a locked block, SR.1 and either SR.4 [program] or SR.5 [erase] will be set to indicate the operation failed. When WP# is at logic high, the lockable blocks are unlocked and can be programmed or erased. See Section 3.3 for details on write protection. VCCQ INPUT OUTPUT VCC: Enables all outputs to be driven to 1.8 V - 2.5 V while the VCC is at 2.7 V-3.3 V. If the VCC is regulated to 2.7 V-2.85 V, VCCQ can be driven at 1.65 V-2.5 V to achieve lowest power operation (see Section 4.4). This input may be tied directly to VCC (2.7 V-3.6 V). VCC VPP DEVICE POWER SUPPLY: 2.7 V-3.6 V PROGRAM/ERASE POWER SUPPLY: Supplies power for Program and Erase operations. VPP may be the same as VCC (2.7 V-3.6 V) for single supply voltage operation. For fast programming at manufacturing, 11.4 V-12.6 V may be supplied to VPP. This pin cannot be left floating. Applying 11.4 V-12.6 V to VPP can only be done for a maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum (see Section 3.4 for details). VPP < VPPLK protects memory contents against inadvertent or unintended program and erase commands. GND GROUND: For all internal circuitry. All ground inputs must be connected. NC NO CONNECT: Pin may be driven or left floating. 2.2 Block Organization The B3 device is an asymmetrically blocked architecture that enables system integration of code and data within a single flash device. Each block can be erased independently of the others up to 100,000 times. For the address locations of each block, see the memory maps in Appendix C. Datasheet 13 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 2.2.1 Parameter Blocks The B3 flash memory architecture includes parameter blocks to facilitate storage of frequently updated small parameters (i.e., data that would normally be stored in an EEPROM). The wordrewrite functionality of EEPROMs can be emulated using software techniques. Each device contains eight parameter blocks of 8 Kbytes/4 Kwords (8192 bytes/4,096 words) each. 2.2.2 Main Blocks After the parameter blocks, the remainder of the array is divided into equal-size main blocks (65,536 bytes/32,768 words) for data or code storage. The 8-Mbit device contains 15 main blocks; 16-Mbit flash has 31 main blocks; 32-Mbit has 63 main blocks; 64-Mbit has 127 main blocks. 3.0 Principles of Operation Flash memory combines EEPROM functionality with in-circuit electrical program-and-erase capability. The B3 device family utilizes a Command User Interface (CUI) and automated algorithms to simplify Program and Erase operations. The CUI allows for 100% CMOS-level control inputs and fixed power supplies during erasure and programming. When VPP < VPPLK, the device will execute only the following commands successfully: Read Array, Read Status Register, Clear Status Register, and Read Identifier. The device provides standard EEPROM read, standby, and Output-Disable operations. Manufacturer identification and device identification data can be accessed through the CUI. All functions associated with altering memory contents, namely program and erase, are accessible via the CUI. The internal Write State Machine (WSM) completely automates Program and Erase operations, while the CUI signals the start of an operation and the status register reports status. The CUI handles the WE# interface to the data and address latches, as well as system status requests during WSM operation. 3.1 Bus Operation The B3 flash memory device performs read, program, and erase in-system via the local CPU or microcontroller. All bus cycles to or from the flash memory conform to standard microcontroller bus cycles. Four control pins dictate the data flow in and out of the flash component: CE#, OE#, WE#, and RP#. Table 3 summarizes these bus operations. Table 3. Bus Operations(1) Mode Read (Array, Status, or Identifier) Output Disable Note RP# CE# OE# WE# DQ0-7 DQ8-15 2-4 VIH VIL VIL VIH DOUT DOUT 2 VIH VIL VIH VIH High Z High Z 2 VIH VIH X X High Z High Z Reset 2, 7 VIL X X X High Z High Z Write 2, 5-7 VIH VIL VIH VIL DIN DIN Standby NOTES: 1. 8-bit devices use only DQ[0:7], 16-bit devices use DQ[0:15]. 2. X must be VIL, VIH for control pins and addresses. 3. See DC Characteristics for VPPLK, VPP1, VPP2, VPP3, VPP4 voltages. 4. Manufacturer and device codes may also be accessed in read identifier mode (A1-A21 = 0). See Table 5. 5. Refer to Table 6 for valid DIN during a Write operation. 6. To program or erase the lockable blocks, hold WP# at VIH. 7. RP# must be at GND 0.2 V to meet the maximum deep power-down current specified. 14 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.1.1 Read The flash memory has four read modes available: read array, read identifier, read status, and read query. These modes are accessible independent of the VPP voltage. The appropriate Read Mode command must be issued to the CUI to enter the corresponding mode. Upon initial device powerup or after exit from reset, the device automatically defaults to read-array mode. CE# and OE# must be driven active to obtain data at the outputs. CE# is the device selection control; when active, it enables the flash memory device. OE# is the data output control, and it drives the selected memory data onto the I/O bus. For all read modes, WE# and RP# must be at VIH. Figure 6 illustrates a read cycle. 3.1.2 Output Disable With OE# at a logic-high level (VIH), the device outputs are disabled. Output pins are placed in a high-impedance state. 3.1.3 Standby Deselecting the device by bringing CE# to a logic-high level (VIH) places the device in standby mode, which substantially reduces device power consumption without any latency for subsequent read accesses. In standby, outputs are placed in a high-impedance state independent of OE#. If deselected during Program or Erase operation, the device continues to consume active power until the Program or Erase operation is complete. 3.1.4 Deep Power-Down / Reset From read mode, RP# at VIL for time tPLPH deselects the memory, places output drivers in a highimpedance state, and turns off all internal circuits. After return from reset, a time tPHQV is required until the initial read-access outputs are valid. A delay (tPHWL or tPHEL) is required after return from reset before a write can be initiated. After this wake-up interval, normal operation is restored. The CUI resets to read-array mode, and the status register is set to 80H. Figure 11A illustrates this case. If RP# is taken low for time tPLPH during a Program or Erase operation, the operation will be aborted and the memory contents at the aborted location (for a program) or block (for an erase) are no longer valid, since the data may be partially erased or written. The abort process goes through the following sequence: 1. When RP# goes low, the device shuts down the operation in progress, a process that takes time tPLRH to complete. 2. After this time tPLRH, the part will either reset to read-array mode (if RP# has gone high during tPLRH, Figure 11B), or enter reset mode (if RP# is still logic low after tPLRH, Figure 11C). 3. In both cases, after returning from an aborted operation, the relevant time tPHQV or tPHWL/ tPHEL must be waited before a Read or Write operation is initiated, as discussed in the previous paragraph. However, in this case, these delays are referenced to the end of tPLRH rather than when RP# goes high. As with any automated device, it is important to assert RP# during system reset. When the system comes out of reset, the processor expects to read from the flash memory. Automated flash memories provide status information when read during program or Block-Erase operations. If a CPU reset occurs with no flash memory reset, proper CPU initialization may not occur because the flash memory may be providing status information instead of array data. Intel(R) Flash memories allow proper CPU initialization following a system reset through the use of the RP# input. In this application, RP# is controlled by the same RESET# signal that resets the system CPU. Datasheet 15 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.1.5 Write A write occurs when both CE# and WE# are low and OE# is high. Commands are written to the Command User Interface (CUI) using standard microprocessor write timings to control Flash operations. The CUI does not occupy an addressable memory location. The address and data buses are latched on the rising edge of the second WE# or CE# pulse, whichever occurs first. Table 6 shows the available commands, and Appendix A provides detailed information on moving between the different modes of operation using CUI commands. Two commands modify array data: Program (40H), and Erase (20H). Writing either of these commands to the internal Command User Interface (CUI) initiates a sequence of internally timed functions that culminate in the completion of the requested task (unless that operation is aborted by either RP# being driven to VIL for tPLRH or an appropriate Suspend command). 3.2 Modes of Operation The flash memory has four read modes (read array, read identifier, read status, and read query; see Appendix B), and two write modes (program and block erase). Three additional modes (erase suspend to program, erase suspend to read, and program suspend to read) are available only during suspended operations. Table 4 summarizes the commands used to reach these modes. Appendix A is a comprehensive chart showing the state transitions. 3.2.1 Read Array When RP# transitions from VIL (reset) to VIH, the device defaults to read-array mode and will respond to the read-control inputs (CE#, address inputs, and OE#) without any additional CUI commands. When the device is in read-array mode, four control signals control data output. * * * * WE# must be logic high (VIH) CE# must be logic low (VIL) OE# must be logic low (VIL) RP# must be logic high (VIH) In addition, the address of the preferred location must be applied to the address pins. If the device is not in read-array mode, as would be the case after a Program or Erase operation, the Read Array command (FFH) must be written to the CUI before array reads can occur. 16 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 4. Command Codes and Descriptions Code Device Mode 00, 01, 60, 2F, C0, 98 Invalid/ Reserved Unassigned commands that should not be used. Intel reserves the right to redefine these codes for future functions. FF Read Array Places the device in read-array mode, such that array data will be output on the data pins. 40 Program Set-Up This is a two-cycle command. The first cycle prepares the CUI for a program operation. The second cycle latches addresses and data information and initiates the WSM to execute the program algorithm. The flash outputs status register data when CE# or OE# is toggled. A Read Array command is required after programming to read array data. See Section 3.2.4. 10 Alternate Program Set-Up (See 40H/Program Set-Up) 20 Erase Set-Up Erase Confirm D0 Description Prepares the CUI for the Erase Confirm command. If the next command is not an Erase Confirm command, then the CUI will (a) set both SR.4 and SR.5 of the status register to a "1," (b) place the device into the read-status-register mode, and (c) wait for another command. See Section 3.2.5. If the previous command was an Erase Set-Up command, then the CUI will close the address and data latches, and begin erasing the block indicated on the address pins. During erase, the device will only respond to the Read Status Register and Erase Suspend commands. The device will output status-register data when CE# or OE# is toggled. Program / Erase Resume If a Program or Erase operation was previously suspended, this command will resume that operation. B0 Program / Erase Suspend Issuing this command will begin to suspend the currently executing Program/Erase operation. The status register will indicate when the operation has been successfully suspended by setting either the program suspend (SR.2) or erase suspend (SR.6), and the WSM status bit (SR.7) to a "1" (ready). The WSM will continue to idle in the SUSPEND state, regardless of the state of all input-control pins except RP#, which will immediately shut down the WSM and the remainder of the chip, if it is driven to VIL. See Section 3.2.4.1 and Section 3.2.4.1. 70 Read Status Register This command places the device into read-status-register mode. Reading the device will output the contents of the status register, regardless of the address presented to the device. The device automatically enters this mode after a Program or Erase operation has been initiated. See Section 3.2.3. 50 Clear Status Register The WSM can set the block-lock status (SR.1), VPP status (SR.3), program status (SR.4), and erase status (SR.5) bits in the status register to "1," but it cannot clear them to "0." Issuing this command clears those bits to "0." 90 Read Identifier Puts the device into the intelligent-identifier-read mode, so that reading the device will output the manufacturer and device codes (A0 = 0 for manufacturer, A0 = 1 for device, all other address inputs must be 0). See Section Section 3.2.2. NOTE: See Appendix A for mode transition information. 3.2.2 Read Identifier To read the manufacturer and device codes, the device must be in read-identifier mode, which can be reached by writing the Read Identifier command (90H). Once in read-identifier mode, A0 = 0 outputs the manufacturer's identification code, and A0 = 1 outputs the device identifier (see Table 5) Note: A1-A21 = 0. To return to read-array mode, write the Read-Array command (FFH). Datasheet 17 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 5. Read Identifier Table Device Identifier Size Mfr. ID -T (Top Boot) 28F004B3 -B (Bottom Boot) D4H D5H 28F400B3 8894H 8895H 28F008B3 D2H D3H 8892H 8893H 0089H 28F800B3 28F016B3 D0H D1H 28F160B3 8890H 8891H 8896H 8897H 8898H 8899H 28F320B3 28F640B3 3.2.3 0089H 0089H Read Status Register The device status register indicates when a Program or Erase operation is complete, and the success or failure of that operation. To read the status register, issue the Read Status Register (70H) command to the CUI. This causes all subsequent Read operations to output data from the status register until another command is written to the CUI. To return to reading from the array, issue the Read Array (FFH) command. The status-register bits are output on DQ0-DQ7. The upper byte, DQ8-DQ15, outputs 00H during a Read Status Register command. The contents of the status register are latched on the falling edge of OE# or CE#, which prevents possible Bus errors that might occur if status-register contents change while being read. CE# or OE# must be toggled with each subsequent status read, or the status register will not indicate completion of a Program or Erase operation. When the WSM is active, SR.7 will indicate the status of the WSM; the remaining bits in the status register indicate whether or not the WSM was successful in performing the preferred operation (see Table 7 on page 21). 3.2.3.1 Clearing the Status Register The WSM sets status bits 1 through 7 to "1," and clears bits 2, 6, and 7 to "0," but cannot clear status bits 1 or 3 through 5 to "0." Because bits 1, 3, 4, and 5 indicate various error conditions, these bits can be cleared only through the Clear Status Register (50H) command. By allowing the system software to control the resetting of these bits, several operations may be performed (such as cumulatively programming several addresses or erasing multiple blocks in sequence) before reading the status register to determine if an error occurred during that series. Clear the status register before beginning another command or sequence. Note, again, that the Read Array command must be issued before data can be read from the memory array. 18 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.2.4 Program Mode Programming is executed using a two-write sequence. The Program Setup command (40H) is written to the CUI followed by a second write that specifies the address and data to be programmed. The WSM will execute a sequence of internally timed events to program preferred bits of the addressed location, then verify the bits are sufficiently programmed. Programming the memory results in specific bits within an address location being changed to a "0." If users attempt to program "1"s, the memory cell contents do not change and no error occurs. The status register indicates programming status: while the program sequence executes, status bit 7 is "0." The status register can be polled by toggling either CE# or OE#. While programming, the only valid commands are Read Status Register, Program Suspend, and Program Resume. When programming is complete, the program-status bits should be checked. If the programming operation was unsuccessful, bit SR.4 of the status register is set to indicate a program failure. If SR.3 is set, then VPP was not within acceptable limits, and the WSM did not execute the program command. If SR.1 is set, a program operation was attempted on a locked block and the operation was aborted. The status register should be cleared before attempting the next operation. Any CUI instruction can follow after programming is completed; however, to prevent inadvertent status-register reads, be sure to reset the CUI to read-array mode. 3.2.4.1 Suspending and Resuming Program The Program Suspend halts the in-progress program operation to read data from another location of memory. Once the programming process starts, writing the Program Suspend command to the CUI requests that the WSM suspend the program sequence (at predetermined points in the program algorithm). The device continues to output status-register data after the Program Suspend command is written. Polling status-register bits SR.7 and SR.2 will determine when the program operation has been suspended (both will be set to "1"). tWHRH1/tEHRH1 specify the programsuspend latency. A Read Array command can now be written to the CUI to read data from blocks other than that which is suspended. The only other valid commands while program is suspended are Read Status Register, Read Identifier, and Program Resume. After the Program Resume command is written to the flash memory, the WSM will continue with the program process and status-register bits SR.2 and SR.7 will automatically be cleared. After the Program Resume command is written, the device automatically outputs status-register data when read (see Appendix E for Program Suspend and Resume Flowchart). VPP must remain at the same VPP level used for program while in programsuspend mode. RP# must also remain at VIH. 3.2.5 Erase Mode To erase a block, write the Erase Set-up and Erase Confirm commands to the CUI, along with an address identifying the block to be erased. This address is latched internally when the Erase Confirm command is issued. Block erasure results in all bits within the block being set to "1." Only one block can be erased at a time. The WSM will execute a sequence of internally timed events to program all bits within the block to "0," erase all bits within the block to "1," then verify that all bits within the block are sufficiently erased. While the erase executes, status bit 7 is a "0." When the status register indicates that erasure is complete, check the erase-status bit to verify that the Erase operation was successful. If the Erase operation was unsuccessful, SR.5 of the status register will be set to a "1," indicating an erase failure. If VPP was not within acceptable limits after Datasheet 19 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 the Erase Confirm command was issued, the WSM will not execute the erase sequence; instead, SR.5 of the status register is set to indicate an Erase error, and SR.3 is set to a "1" to identify that VPP supply voltage was not within acceptable limits. After an Erase operation, clear the status register (50H) before attempting the next operation. Any CUI instruction can follow after erasure is completed; however, to prevent inadvertent statusregister reads, it is advisable to place the flash in read-array mode after the erase is complete. 3.2.5.1 Suspending and Resuming Erase Since an Erase operation requires on the order of seconds to complete, an Erase Suspend command is provided to allow erase-sequence interruption in order to read data from--or program data to-- another block in memory. Once the erase sequence is started, writing the Erase Suspend command to the CUI requests that the WSM pause the erase sequence at a predetermined point in the erase algorithm. The status register will indicate if/when the Erase operation has been suspended. A Read Array/Program command can now be written to the CUI in order to read data from/ program data to blocks other than the one currently suspended. The Program command can subsequently be suspended to read yet another array location. The only valid commands while Erase is suspended are Erase Resume, Program, Read Array, Read Status Register, or Read Identifier. During erase-suspend mode, the chip can be placed in a pseudo-standby mode by taking CE# to VIH, which reduces active current consumption. Erase Resume continues the erase sequence when CE# = VIL. As with the end of a standard Erase operation, the status register must be read and cleared before the next instruction is issued. Table 6. (1,4) Command Bus Definitions First Bus Cycle Command Notes Second Bus Cycle Oper Addr Data Write X FFH Write X Read Status Register Write Clear Status Register Read Array Read Identifier Program 2 3 Oper Addr Data 90H Read IA ID X 70H Read X SRD Write X 50H Write X 40H / 10H Write PA PD Write BA D0H Block Erase/Confirm Write X 20H Program/Erase Suspend Write X B0H Program/Erase Resume Write X D0H NOTES: PA: Program Address PD: Program Data BA: Block Address IA: Identifier Address ID: Identifier Data SRD: Status Register Data 1. Bus operations are defined in Table 3. 2. Following the Intelligent Identifier command, two Read operations access manufacturer and device codes. A 0 = 0 for manufacturer code, A0 = 1 for device code. A1-A21 = 0. 3. Either 40H or 10H command is valid although the standard is 40H. 4. When writing commands to the device, the upper data bus [DQ 8-DQ15] should be either VIL or VIH, to minimize current draw. 20 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 7. Status Register Bit Definition WSMS ESS ES PS VPPS PSS BLS R 7 6 5 4 3 2 1 0 NOTES: SR.7 = WRITE STATE MACHINE STATUS (WSMS) 1 = Ready 0 = Busy Check Write State Machine bit first to determine word program or block-erase completion, before checking program or erasestatus bits. SR.6 = ERASE-SUSPEND STATUS (ESS) 1 = Erase Suspended 0 = Erase In Progress/Completed When erase suspend is issued, WSM halts execution and sets both WSMS and ESS bits to "1." ESS bit remains set at "1" until an Erase Resume command is issued. SR.5 = ERASE STATUS (ES) 1 = Error In Block Erasure 0 = Successful Block Erase When this bit is set to "1," WSM has applied the max. number of erase pulses to the block and is still unable to verify successful block erasure. SR.4 = PROGRAM STATUS (PS) 1 = Error in Word Program 0 = Successful Word Program When this bit is set to "1," WSM has attempted but failed to program a word. SR.3 = VPP STATUS (VPPS) 1 = VPP Low Detect, Operation Abort 0 = VPP OK The VPP status bit does not provide continuous indication of VPP level. The WSM interrogates VPP level only after the Program or Erase command sequences have been entered, and informs the system if VPP has not been switched on. The VPP is also checked before the operation is verified by the WSM. The VPP status bit is not guaranteed to report accurate feedback between VPPLK max and VPP1 min or between VPP1 max and VPP4 min. SR.2 = PROGRAM SUSPEND STATUS (PSS) 1 = Program Suspended 0 = Program in Progress/Completed When program suspend is issued, WSM halts execution and sets both WSMS and PSS bits to "1." PSS bit remains set to "1" until a Program Resume command is issued. SR.1 = BLOCK LOCK STATUS 1 = Program/Erase attempted on locked block; Operation aborted 0 = No operation to locked blocks If a Program or Erase operation is attempted to one of the locked blocks, this bit is set by the WSM. The operation specified is aborted and the device is returned to read status mode. SR.0 = RESERVED FOR FUTURE ENHANCEMENTS (R) This bit is reserved for future use and should be masked out when polling the status register. NOTE: A Command Sequence Error is indicated when SR.4, SR.5, and SR.7 are set. 3.3 Block Locking The B3 device architecture features two hardware-lockable parameter blocks. 3.3.1 WP# = VIL for Block Locking The lockable blocks are locked when WP# = VIL; any program or Erase operation to a locked block will result in an error, which will be reflected in the status register. For top configuration, the top two parameter blocks (blocks #133 and #134 for the 64 Mbit, #69 and #70 for the 32 Mbit, blocks #37 and #38 for the 16 Mbit, blocks #21 and #22 for the 8 Mbit, blocks #13 and #14 for the 4 Mbit) are lockable. For the bottom configuration, the bottom two parameter blocks (blocks #0 and #1 for 4 /8 /16 /32/64 Mbit) are lockable. Unlocked blocks can be programmed or erased normally (unless VPP is below VPPLK). Datasheet 21 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.3.2 WP# = VIH for Block Unlocking WP# = VIH unlocks all lockable blocks. These blocks can now be programmed or erased. Note that RP# does not override WP# locking as in previous Boot Block devices. WP# controls all block locking and VPP provides protection against spurious writes. Table 8 defines the writeprotection methods. Table 8. 3.4 Write-Protection Truth Table for the B3 Device Family VPP WP# RP# Write Protection Provided X X VIL All Blocks Locked VIL X VIH All Blocks Locked VPPLK VIL VIH Lockable Blocks Locked VPPLK VIH VIH All Blocks Unlocked VPP Program and Erase Voltages The B3 products provide in-system programming and erase at 2.7 V. For customers requiring fast programming in their manufacturing environment, B3 device includes an additional low-cost 12-V programming feature. The 12-V VPP mode enhances programming performance during the short period of time typically found in manufacturing processes; however, it is not intended for extended use. 12 V may be applied to VPP during program and Erase operations for a maximum of 1000 cycles on the main blocks, and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. Warning: Stressing the device beyond these limits may cause permanent damage. During Read operations or idle times, VPP may be tied to a 5-V supply. For Program and Erase operations, a 5-V supply is not permitted. The VPP must be supplied with either 2.7 V-3.6 V or 11.4 V-12.6 V during Program and Erase operations. 3.4.1 VPP = VIL for Complete Protection The VPP programming voltage can be held low for complete write protection of all blocks in the flash device. When VPP is below VPPLK, any Program or Erase operation will result in a error, prompting the corresponding status-register bit (SR.3) to be set. 3.5 Power Consumption Intel flash devices have a tiered approach to power savings that can significantly reduce overall system power consumption. The Automatic Power Savings (APS) feature reduces power consumption when the device is selected but idle. If the CE# is deasserted, the flash enters its standby mode, where current consumption is even lower. The combination of these features can minimize memory power consumption, and therefore, overall system power consumption. 22 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.5.1 Active Power With CE# at a logic-low level and RP# at a logic-high level, the device is in the active mode. Refer to the DC Characteristic tables for ICC current values. Active power is the largest contributor to overall system power consumption. Minimizing the active current could have a profound effect on system power consumption, especially for battery-operated devices. 3.5.2 Automatic Power Savings (APS) Automatic Power Savings provides low-power operation during read mode. After data is read from the memory array and the address lines are quiescent, APS circuitry places the device in a mode where typical current is comparable to ICCS. The flash stays in this static state with outputs valid until a new location is read. 3.5.3 Standby Power With CE# at a logic-high level (VIH) and the device in read mode, the flash memory is in standby mode, which disables much of the device circuitry, and substantially reduces power consumption. Outputs are placed in a high-impedance state independent of the status of the OE# signal. If CE# transitions to a logic-high level during Erase or Program operations, the device will continue to perform the operation and consume corresponding active power until the operation is completed. System engineers should analyze the breakdown of standby time versus active time, and quantify the respective power consumption in each mode for their specific application. This approach will provide a more accurate measure of application-specific power and energy requirements. 3.5.4 Deep Power-Down Mode The deep power-down mode is activated when RP# = VIL (GND 0.2 V). During read modes, RP# going low de-selects the memory and places the outputs in a high-impedance state. Recovery from deep power-down requires a minimum time of tPHQV (See "AC Read Characteristics" on page 30.) During program or erase modes, RP# transitioning low will abort the in-progress operation. The memory contents of the address being programmed or the block being erased are no longer valid as the data integrity has been compromised by the abort. During deep power-down, all internal circuits are switched to a low-power savings mode (RP# transitioning to VIL or turning off power to the device clears the status register). 3.6 Power and Reset Considerations 3.6.1 Power-Up/Down Characteristics To prevent any condition that may result in a spurious write or erase operation, it is recommended to power-up VCC and VCCQ together. Conversely, VCC and VCCQ must power-down together. It is also recommended to power-up VPP with or slightly after VCC. Conversely, VPP must powerdown with or slightly before VCC. If VCCQ and/or VPP are not connected to the VCC supply, then VCC should attain VCCMin before applying VCCQ and VPP. Device inputs should not be driven before supply voltage = VCCMin. Power supply transitions should only occur when RP# is low. Datasheet 23 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 3.6.2 RP# Connected to System Reset The use of RP# during system reset is important with automated program/erase devices because the system expects to read from the flash memory when it exits reset. If a CPU reset occurs without a flash memory reset, proper CPU initialization will not occur because the flash memory may be providing status information instead of array data. Intel recommends connecting RP# to the system CPU RESET# signal to allow proper CPU/flash initialization following system reset. System designers must guard against spurious writes when VCC voltages are above VLKO. Because both WE# and CE# must be low for a command write, driving either signal to VIH will inhibit writes to the device. The CUI architecture provides additional protection since alteration of memory contents can occur only after successful completion of the two-step command sequences. The device is also disabled until RP# is brought to VIH, regardless of the state of its control inputs. By holding the device in reset (RP# connected to system POWERGOOD) during power-up/down, invalid bus conditions during power-up can be masked, providing yet another level of memory protection. 3.6.3 VCC, VPP and RP# Transitions The CUI latches commands as issued by system software and is not altered by VPP or CE# transitions or WSM actions. Its default state upon power-up, after exit from reset mode or after VCC transitions above VLKO (Lockout voltage), is read-array mode. After any program or Block-Erase operation is complete (even after VPP transitions down to VPPLK), the CUI must be reset to read-array mode via the Read Array command if access to the flash-memory array is required. 3.7 Power Supply Decoupling Flash memory power-switching characteristics require careful device decoupling. System designers should consider the following three supply current issues: 1. Standby current levels (ICCS) 2. Read current levels (ICCR) 3. Transient peaks produced by falling and rising edges of CE#. Transient current magnitudes depend on the device outputs' capacitive and inductive loading. Twoline control and proper decoupling capacitor selection will suppress these transient voltage peaks. Each flash device should have a 0.1 F ceramic capacitor connected between each VCC and GND, and between its VPP and GND. These high-frequency, inherently low-inductance capacitors should be placed as close as possible to the package leads. 24 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 4.0 Thermal and DC Characteristics 4.1 Absolute Maximum Ratings Warning: Stressing the device beyond the "Absolute Maximum Ratings" may cause permanent damage. These are stress ratings only. Operation beyond the "Operating Conditions" is not recommended, and extended exposure beyond the "Operating Conditions" may affect device reliability. . NOTICE: Specifications are subject to change without notice. Verify with your local Intel Sales office that you have the latest datasheet before finalizing a design. Parameter Maximum Rating Notes Extended Operating Temperature During Read -40 C to +85 C During Block Erase and Program -40 C to +85 C Temperature under Bias -40 C to +85 C Storage Temperature -65 C to +125 C Voltage On Any Pin (except VCC and VPP) with Respect to GND -0.5 V to +3.7 V 1 VPP Voltage (for Block Erase and Program) with Respect to GND -0.5 V to +13.5 V 1,2,3 VCC and VCCQ Supply Voltage with Respect to GND -0.2 V to +3.6 V Output Short Circuit Current 100 mA 4 NOTES: 1. Minimum DC voltage is -0.5 V on input/output pins. During transitions, this level may undershoot to -2.0 V for periods <20 ns. Maximum DC voltage on input/output pins is VCC +0.5 V which, during transitions, may overshoot to VCC +2.0 V for periods <20 ns. 2. Maximum DC voltage on VPP may overshoot to +14.0 V for periods <20 ns. 3. VPP Program voltage is normally 1.65 V-3.6 V. Connection to a 11.4 V-12.6 V supply can be done for a maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter blocks during program/erase. VPP may be connected to 12 V for a total of 80 hours maximum. 4. Output shorted for no more than one second. No more than one output shorted at a time. Datasheet 25 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 4.2 Table 9. Operating Conditions Temperature and Voltage Operating Conditions Symbol Parameter TA Operating Temperature VCC1 VCC Supply Voltage Notes VCC2 VCCQ1 VCCQ2 VPP2 Cycling Block Erase Cycling Units -40 +85 C 2.7 3.6 Volts 1, 2 3.0 3.6 1 2.7 3.6 1.65 2.5 1.8 2.5 1 1.65 3.6 Volts 1, 3 11.4 12.6 Volts 3 100,000 I/O Supply Voltage Supply Voltage Max 1, 2 VCCQ3 VPP1 Min Volts Cycles NOTES: 1. VCC and VCCQ must share the same supply when they are in the VCC1 range. 2. VCCMax = 3.3 V for 0.25m 32-Mbit devices. 3. Applying VPP = 11.4 V-12.6 V during a program/erase can only be done for a maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. 4.3 DC Current Characteristics Table 10. DC Current Characteristics (Sheet 1 of 3) Sym ILI ILO 26 Parameter Input Load Current Output Leakage Current VCC 2.7 V-3.6 V 2.7 V-2.85 V 2.7 V-3.3 V VCCQ 2.7 V-3.6 V 1.65 V-2.5 V 1.8 V-2.5 V Note Typ Typ Typ 1,2 1,2 Max 1 10 Max 1 10 Unit Test Conditions A VCC = VCCMax VCCQ = VCCQMax VIN = VCCQ or GND A VCC = VCCMax VCCQ = VCCQMax VIN = VCCQ or GND Max 1 10 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 10. DC Current Characteristics (Sheet 2 of 3) Sym ICCS ICCD VCC 2.7 V-3.6 V 2.7 V-2.85 V 2.7 V-3.3 V VCCQ 2.7 V-3.6 V 1.65 V-2.5 V 1.8 V-2.5 V Note Typ Max Typ Max Typ Max VCC Standby Current for 0.13 and 0.18 Micron Product 1 7 15 20 50 150 250 A VCC Standby Current for 0.25 Micron Product 1 10 25 20 50 150 250 A VCC Power-Down Current for 0.13 and 0.18 Micron Product 1,2 7 15 7 20 7 20 A VCC Power-Down Current for 0.25 Product 1,2 7 25 7 25 7 25 A VCC Read Current for 0.13 and 0.18 Micron Product 1,2,3 9 18 8 15 9 15 mA VCC Read Current for 0.25 Micron Product 1,2,3 10 18 8 15 9 15 mA 1 0.2 5 0.2 5 0.2 5 A RP# = GND 0.2 V VPP VCC 18 55 18 55 18 55 mA VPP =VPP1, Program in Progress 8 22 10 30 10 30 mA 16 45 21 45 21 45 mA 8 15 16 45 16 45 mA 7 15 50 200 50 200 A 10 25 50 200 50 200 A Parameter Unit ICCW ICCE ICCES/ ICCWS Datasheet VPP Deep PowerDown Current VCC Program Current VCC Erase Current 1,4 1,4 VCC Erase Suspend Current for 0.13 and 0.18 Micron Product VCC = VCCMax VCCQ = VCCQMax VIN = VCCQ or GND RP# = GND 0.2 V VCC = VCCMax VCCQ = VCCQMax OE# = VIH, CE# =VIL f = 5 MHz, IOUT=0 mA Inputs = VIL or VIH VPP = (12v) VPP2 Program in Progress VPP = VPP1, Erase in Progress VPP = VPP2 1,4,5 VCC Erase Suspend Current for 0.25 Micron Product VCC = VCCMax CE# = RP# = VCCQ or during Program/ Erase Suspend WP# = VCCQ or GND ICCR IPPD Test Conditions (12v) , Erase in Progress CE# = VIH, Erase Suspend in Progress 27 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 10. DC Current Characteristics (Sheet 3 of 3) Sym IPPR IPPW IPPE Parameter VPP Read Current VPP Program Current VPP Erase Current VCC 2.7 V-3.6 V 2.7 V-2.85 V 2.7 V-3.3 V VCCQ 2.7 V-3.6 V 1.65 V-2.5 V 1.8 V-2.5 V Note Typ Max Typ Max Typ Max 2 15 2 15 2 15 A VPP VCC 50 200 50 200 50 200 A VPP > VCC 0.05 0.1 0.05 0.1 0.05 0.1 mA VPP =VPP1, Program in Progress 8 22 8 22 8 22 mA 0.05 0.1 0.05 0.1 0.05 0.1 mA 8 22 16 45 16 45 mA 1,4 1,4 VCC Erase Suspend Current Test Conditions VPP = VPP2 1,4 0.2 IPPES/ IPPWS Unit 5 0.2 5 0.2 5 A 1,4 (12v) Program in Progress VPP = VPP1, Erase in Progress VPP = (12v) , Erase in Progress VPP = VPP1, Program or Erase Suspend in Progress VPP = (12v) , 50 200 50 200 50 200 A VPP2 VPP2 Program or Erase Suspend in Progress NOTES: 1. All currents are in RMS unless otherwise noted. Typical values at nominal VCC, TA = +25 C. 2. The test conditions VCCMax, VCCQMax, VCCMin, and VCCQMin refer to the maximum or minimum VCC or VCCQ voltage listed at the top of each column. VCCMax = 3.3 V for 0.25m 32-Mbit devices. 3. Automatic Power Savings (APS) reduces ICCR to approximately standby levels in static operation (CMOS inputs). 4. Sampled, not 100% tested. 5. ICCES or ICCWS is specified with device de-selected. If device is read while in erase suspend, current draw is sum of ICCES and ICCR. If the device is read while in program suspend, current draw is the sum of ICCWS and ICCR. 28 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 4.4 DC Voltage Characteristics Table 11. DC Voltage Characteristics Sym Parameter VCC 2.7 V-3.6 V 2.7 V-2.85 V 2.7 V-3.3 V VCCQ 2.7 V-3.6 V 1.65 V-2.5 V 1.8 V-2.5 V Note Min Max Min Max Min Max Unit Test Conditions VIL Input Low Voltage -0.4 VCC * 0.22 V -0.4 0.4 -0.4 0.4 V VIH Input High Voltage 2.0 VCCQ +0.3V VCCQ - 0.4V VCCQ +0.3V VCCQ - 0.4V VCCQ +0.3V V VOL Output Low Voltage -0.1 0.1 -0.1 0.1 -0.1 0.1 V VCC = VCCMin VCCQ = VCCQMin IOL = 100 A VOH Output High Voltage VCCQ -0.1V V VCC = VCCMin VCCQ = VCCQMin IOH = -100 A VPPLK VPP LockOut Voltage 1.0 V Complete Write Protection VPP1 VPP2 VPP during Program / Erase Operations 1 VCCQ - 0.1V 1.0 VCCQ - 0.1V 1.0 1 1.65 3.6 1.65 3.6 1.65 3.6 V 1,2 11.4 12.6 11.4 12.6 11.4 12.6 V VLKO VCC Prog/ Erase Lock Voltage 1.5 1.5 1.5 V VLKO2 VCCQ Prog/ Erase Lock Voltage 1.2 1.2 1.2 V NOTES: 1. Erase and Program are inhibited when VPP < VPPLK and not guaranteed outside the valid VPP ranges of VPP1 and VPP2. 2. Applying VPP = 11.4 V-12.6 V during program/erase can only be done for a maximum of 1000 cycles on the main blocks and 2500 cycles on the parameter blocks. VPP may be connected to 12 V for a total of 80 hours maximum. Datasheet 29 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 5.0 AC Characteristics 5.1 AC Read Characteristics Table 12. Read Operations--8 Mbit Density Density 8 Mbit Product # Sym 90 ns 110 ns Parameter Unit 3.0 V - 3.6 V 2.7 V - 3.6 V 3.0 V - 3.6 V 2.7 V - 3.6 V Note Min Min Min Min 80 VCC Max Max tAVAV Read Cycle Time 3,4 R2 tAVQV Address to Output Delay 3,4 80 90 100 110 ns R3 tELQV CE# to Output Delay 1,3,4 80 90 100 110 ns R4 tGLQV OE# to Output Delay 1,3,4 30 30 30 30 ns R5 tPHQV RP# to Output Delay 3,4 150 150 150 150 ns R6 tELQX CE# to Output in Low Z 2,3,4 0 0 0 0 ns R7 tGLQX OE# to Output in Low Z 2,3,4 0 0 0 0 ns R8 tEHQZ CE# to Output in High Z 2,3,4 20 20 20 20 ns R9 tGHQZ OE# to Output in High Z 2,3,4 20 20 20 20 ns tOH Output Hold from Address, CE#, or OE# Change, Whichever Occurs First 2,3,4 0 0 100 Max R1 R10 90 Max 0 110 0 ns ns NOTES: 1. OE# may be delayed up to tELQV-tGLQV after the falling edge of CE# without impact on tELQV. 2. Sampled, but not 100% tested. 3. See Figure 6, "Read Operation Waveform" on page 33. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 30 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 13. Read Operations--16 Mbit Density Density # Sym Paramete r 16 Mbit Product 70 ns 80 ns VCC 2.7 V-3.6 V 2.7 V-3.6 V 3.0 V-3.6 V 2.7 V-3.6 V 3.0 V-3.6V 2.7 V-3.6V Min Min Min Min Min Min Max 70 Max 80 90 ns Max 80 110 ns Max 90 Max 100 Unit Notes ns 3,4 Max 110 R1 tAVAV Read Cycle Time R2 tAVQ Address to Output Delay 70 80 80 90 100 110 ns 3,4 R3 tELQ CE# to Output Delay 70 80 80 90 100 110 ns 1,3,4 R4 tGLQ OE# to Output Delay 20 20 30 30 30 30 ns 1,3,4 R5 tPHQ RP# to Output Delay 150 150 150 150 150 150 ns 3,4 R6 tELQ R7 tGLQ R8 tEHQ R9 tGHQ R10 tOH V V V V X X Z Z CE# to Output in Low Z 0 0 0 0 0 0 ns 2,3,4 OE# to Output in Low Z 0 0 0 0 0 0 ns 2,3,4 CE# to Output in High Z 20 20 20 20 20 20 ns 2,3,4 OE# to Output in High Z 20 20 20 20 20 20 ns 2,3,4 ns 2,3,4 Output Hold from Address, CE#, or OE# Change, Whichever Occurs First 0 0 0 0 0 0 NOTES: 1. OE# may be delayed up to tELQV-tGLQV after the falling edge of CE# without impact on tELQV. 2. Sampled, but not 100% tested. 3. See Figure 6, "Read Operation Waveform" on page 33. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. Datasheet 31 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 14. Read Operations--32 Mbit Density Density # Sym Parameter 32 Mbit Product 70 ns 90 ns VCC 2.7 V-3.6 V 2.7 V-3.6 V 3.0 V-3.3 V 2.7 V-3.3 V 3.0 V-3.3 V 2.7 V-3.3 V Min Min Min Min Min Min Max 70 Max 90 100 ns Max 90 110 ns Max 100 Max 100 Unit Notes ns 3,4 Max 110 R1 tAVAV Read Cycle Time R2 tAVQ Address to Output Delay 70 90 90 100 100 110 ns 3,4 R3 tELQ CE# to Output Delay 70 90 90 100 100 110 ns 1,3,4 R4 tGLQ OE# to Output Delay 20 20 30 30 30 30 ns 1,3,4 R5 tPHQ RP# to Output Delay 150 150 150 150 150 150 ns 3,4 R6 tELQ R7 tGLQ R8 tEHQ R9 tGHQ R10 tOH V V V V X X Z Z CE# to Output in Low Z 0 0 0 0 0 0 ns 2,3,4 OE# to Output in Low Z 0 0 0 0 0 0 ns 2,3,4 CE# to Output in High Z 20 20 20 20 20 20 ns 2,3,4 OE# to Output in High Z 20 20 20 20 20 20 ns 2,3,4 ns 2,3,4 Output Hold from Address, CE#, or OE# Change, Whichever Occurs First 0 0 0 0 0 0 NOTES: 1. OE# may be delayed up to tELQV-tGLQV after the falling edge of CE# without impact on tELQV. 2. Sampled, but not 100% tested. 3. See Figure 6, "Read Operation Waveform" on page 33. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 32 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 15. Read Operations -- 64 Mbit Density Density # Sym 64 Mbit Product 70 ns 80 ns VCC 2.7 V-3.6 V 2.7 V-3.6 V Note Min Min 70 Parameter Unit Max Max R1 tAVAV Read Cycle Time 3,4 R2 tAVQV Address to Output Delay 3,4 70 80 ns R3 tELQV CE# to Output Delay 1,3,4 70 80 ns R4 tGLQV OE# to Output Delay 1,3,4 20 20 ns R5 tPHQV RP# to Output Delay 3,4 150 150 ns R6 tELQX CE# to Output in Low Z R7 tGLQX R8 tEHQZ R9 tGHQZ R10 tOH 80 ns 2,3,4 0 OE# to Output in Low Z 2,3,4 0 CE# to Output in High Z 2,3,4 20 20 ns OE# to Output in High Z 2,3,4 20 20 ns Output Hold from Address, CE#, or OE# Change, Whichever Occurs First 2,3,4 0 0 ns 0 ns 0 ns NOTES: 1. OE# may be delayed up to tELQV-tGLQV after the falling edge of CE# without impact on tELQV. 2. Sampled, but not 100% tested. 3. See Figure 6, "Read Operation Waveform" on page 33. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. Figure 6. Read Operation Waveform R1 R2 Address [A] R3 R8 CE# [E] R4 R9 OE# [G] WE# [W] R7 R6 R10 Data [D/Q] R5 RST# [P] Datasheet 33 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 5.2 AC Write Characteristics Table 16. Write Operations--8 Mbit Density Density 8 Mbit Product # Sym Parameter 90 ns 3.0 V - 3.6 V 110 ns 80 100 Unit VCC 2.7 V - 3.6 V 90 110 Note Min Min Min Min W1 tPHWL / tPHEL RP# High Recovery to WE# (CE#) Going Low 4,5 150 150 150 150 ns W2 tELWL / tWLEL CE# (WE#) Setup to WE# (CE#) Going Low 4,5 0 0 0 0 ns W3 tWLWH / tELEH WE# (CE#) Pulse Width 4,5 50 60 70 70 ns W4 tDVWH / tDVEH Data Setup to WE# (CE#) Going High 2,4,5 50 50 60 60 ns W5 tAVWH / tAVEH Address Setup to WE# (CE#) Going High 2,4,5 50 60 70 70 ns W6 tWHEH / tEHWH CE# (WE#) Hold Time from WE# (CE#) High 4,5 0 0 0 0 ns W7 tWHDX / tEHDX Data Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 ns W8 tWHAX / tEHAX Address Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 ns W9 tWHWL / tEHEL WE# (CE#) Pulse Width High 2,4,5 30 30 30 30 ns W10 tVPWH / tVPEH VPP Setup to WE# (CE#) Going High 3,4,5 200 200 200 200 ns W11 tQVVL VPP Hold from Valid SRD 3,4 0 0 0 0 ns W12 tBHWH / tBHEH WP# Setup to WE# (CE#) Going High 3,4 0 0 0 0 ns W13 tQVBL WP# Hold from Valid SRD 3,4 0 0 0 0 ns W14 tWHGL WE# High to OE# Going Low 3,4 30 30 30 30 ns NOTES: 1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high (whichever goes high first). Hence, tWP = tWLWH = tELEH = tWLEH = tELWH. Similarly, write pulse width high (tWPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low last). Hence, tWPH = tWHWL = tEHEL = tWHEL = tEHWL. 2. Refer to Table 3, "Bus Operations(1)" on page 14 for valid AIN or DIN. 3. Sampled, but not 100% tested. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 5. See Figure 7, "Write Operations Waveform" on page 38. 34 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 17. Write Operations--16 Mbit Density Density 16 Mbit Product # Sym Parameter 70 ns 80 ns 3.0 V - 3.6 V 90 ns 110 ns 80 100 Unit VCC 2.7 V - 3.6 V 70 80 90 110 Note Min Min Min Min Min Min W1 tPHWL / tPHEL RP# High Recovery to WE# (CE#) Going Low 4,5 150 150 150 150 150 150 ns W2 tELWL / tWLEL CE# (WE#) Setup to WE# (CE#) Going Low 4,5 0 0 0 0 0 0 ns W3 tWLWH / tELEH WE# (CE#) Pulse Width 1,4,5 45 50 50 60 70 70 ns W4 tDVWH / tDVEH Data Setup to WE# (CE#) Going High 2,4,5 40 40 50 50 60 60 ns W5 tAVWH / tAVEH Address Setup to WE# (CE#) Going High 2,4,5 50 50 50 60 70 70 ns W6 tWHEH / tEHWH CE# (WE#) Hold Time from WE# (CE#) High 4,5 0 0 0 0 0 0 ns W7 tWHDX / tEHDX Data Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 0 0 ns W8 tWHAX / tEHAX Address Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 0 0 ns W9 tWHWL / tEHEL WE# (CE#) Pulse Width High 1,4,5 25 30 30 30 30 30 ns W10 tVPWH / tVPEH VPP Setup to WE# (CE#) Going High 3,4,5 200 200 200 200 200 200 ns W11 tQVVL VPP Hold from Valid SRD 3,4 0 0 0 0 0 0 ns W12 tBHWH / tBHEH WP# Setup to WE# (CE#) Going High 3,4 0 0 0 0 0 0 ns W13 tQVBL WP# Hold from Valid SRD 3,4 0 0 0 0 0 0 ns W14 tWHGL WE# High to OE# Going Low 3,4 30 30 30 30 30 30 ns NOTES: 1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high (whichever goes high first). Hence, tWP = tWLWH = tELEH = tWLEH = tELWH. Similarly, write pulse width high (tWPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low last). Hence, tWPH = tWHWL = tEHEL = tWHEL = tEHWL. 2. Refer to Table 3, "Bus Operations(1)" on page 14 for valid AIN or DIN. 3. Sampled, but not 100% tested. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 5. See Figure 7, "Write Operations Waveform" on page 38. Datasheet 35 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 18. Write Operations--32 Mbit Density Density 32 Mbit Product # Sym 70 ns 90 ns 3.0 V - 3.6 V6 Parameter 100 ns 110 ns 90 100 Unit VCC 2.7 V - 3.6 V 70 90 100 110 Note Min Min Min Min Min Min W1 tPHWL / tPHEL RP# High Recovery to WE# (CE#) Going Low 4,5 150 150 150 150 150 150 ns W2 tELWL / tWLEL CE# (WE#) Setup to WE# (CE#) Going Low 4,5 0 0 0 0 0 0 ns W3 tWLWH / tELEH WE# (CE#) Pulse Width 1,4,5 45 60 60 70 70 70 ns W4 tDVWH / tDVEH Data Setup to WE# (CE#) Going High 2,4,5 40 40 50 60 60 60 ns W5 tAVWH / tAVEH Address Setup to WE# (CE#) Going High 2,4,5 50 60 60 70 70 70 ns W6 tWHEH / tEHWH CE# (WE#) Hold Time from WE# (CE#) High 4,5 0 0 0 0 0 0 ns W7 tWHDX / tEHDX Data Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 0 0 ns W8 tWHAX / tEHAX Address Hold Time from WE# (CE#) High 2,4,5 0 0 0 0 0 0 ns W9 tWHWL / tEHEL WE# (CE#) Pulse Width High 1,4,5 25 30 30 30 30 30 ns W10 tVPWH / tVPEH VPP Setup to WE# (CE#) Going High 3,4,5 200 200 200 200 200 200 ns W11 tQVVL VPP Hold from Valid SRD 3,4 0 0 0 0 0 0 ns W12 tBHWH / tBHEH WP# Setup to WE# (CE#) Going High 3,4 0 0 0 0 0 0 ns W13 tQVBL WP# Hold from Valid SRD 3,4 0 0 0 0 0 0 ns W14 tWHGL WE# High to OE# Going Low 3,4 30 30 30 30 30 30 ns NOTES: 1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high (whichever goes high first). Hence, tWP = tWLWH = tELEH = tWLEH = tELWH. Similarly, write pulse width high (tWPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low last). Hence, tWPH = tWHWL = tEHEL = tWHEL = tEHWL. 2. Refer to Table 3, "Bus Operations(1)" on page 14 for valid AIN or DIN. 3. Sampled, but not 100% tested. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 5. See Figure 7, "Write Operations Waveform" on page 38. 6. VCCMax = 3.3 V for 32-Mbit 0.25 Micron product. 36 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 19. Write Operations--64Mbit Density # Sym Parameter VCC Density 64 Mbit Product 80 ns 2.7 V - 3.6 V Note Min Unit W1 tPHWL / tPHEL RP# High Recovery to WE# (CE#) Going Low 4,5 150 ns W2 tELWL / tWLEL CE# (WE#) Setup to WE# (CE#) Going Low 4,5 0 ns W3 tWLWH / tELEH WE# (CE#) Pulse Width 1,4,5 60 ns W4 tDVWH / tDVEH Data Setup to WE# (CE#) Going High 2,4,5 40 ns W5 tAVWH / tAVEH Address Setup to WE# (CE#) Going High 2,4,5 60 ns W6 tWHEH / tEHWH CE# (WE#) Hold Time from WE# (CE#) High 4,5 0 ns W7 tWHDX / tEHDX Data Hold Time from WE# (CE#) High 2,4,5 0 ns W8 tWHAX / tEHAX Address Hold Time from WE# (CE#) High 2,4,5 0 ns W9 tWHWL / tEHEL WE# (CE#) Pulse Width High 1,4,5 30 ns W10 tVPWH / tVPEH VPP Setup to WE# (CE#) Going High 3,4,5 200 ns W11 tQVVL VPP Hold from Valid SRD 3,4 0 ns W12 tBHWH / tBHEH WP# Setup to WE# (CE#) Going High 3,4 0 ns W13 tQVBL WP# Hold from Valid SRD 3,4 0 ns W14 tWHGL WE# High to OE# Going Low 3,4 30 ns NOTES: 1. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high (whichever goes high first). Hence, tWP = tWLWH = tELEH = tWLEH = tELWH. Similarly, write pulse width high (tWPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going low (whichever goes low last). Hence, tWPH = tWHWL = tEHEL = tWHEL = tEHWL. 2. Refer to Table 3, "Bus Operations(1)" on page 14 for valid AIN or DIN. 3. Sampled, but not 100% tested. 4. See Figure 9, "AC Input/Output Reference Waveform" on page 40 for timing measurements and maximum allowable input slew rate. 5. See Figure 7, "Write Operations Waveform" on page 38. Datasheet 37 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 7. Write Operations Waveform W5 W8 Address [A] W6 CE# [E] W3 W2 W9 WE# [W] OE# [G] W4 W7 Data [D/Q] W1 RP# [P] W10 Vpp [V] 5.3 Erase and Program Timings Table 20. Erase and Program Timings Symbol VPP 1.65 V-3.6 V 11.4 V-12.6 V Note Typ Max Typ Max Parameter Unit tBWPB 4-KW Parameter Block Word Program Time 1, 2, 3 0.10 0.30 0.03 0.12 s tBWMB 32-KW Main Block Word Program Time 1, 2, 3 0.8 2.4 0.24 1 s Word Program Time for 0.13 and 0.18 Micron Product 1, 2, 3 12 200 8 185 s Word Program Time for 0.25 Micron Product 1, 2, 3 22 200 8 185 s tWHQV2 / tEHQV2 4-KW Parameter Block Erase Time 1, 2, 3 0.5 4 0.4 4 s tWHQV3 / tEHQV3 32-KW Main Block Erase Time 1, 2, 3 1 5 0.6 5 s tWHRH1 / tEHRH1 Program Suspend Latency 1,3 5 10 5 10 s tWHRH2 / tEHRH2 Erase Suspend Latency 1,3 5 20 5 20 s tWHQV1 / tEHQV1 NOTES: 1. Typical values measured at TA= +25 C and nominal voltages. 2. Excludes external system-level overhead. 3. Sampled, but not 100% tested. 38 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 5.4 Reset Specifications Table 21. Reset Specifications VCC 2.7 V - 3.6 V Symbol Parameter Notes Unit Min Max tPLPH RP# Low to Reset during Read (If RP# is tied to VCC, this specification is not applicable) tPLRH1 RP# Low to Reset during Block Erase 3 22 s tPLRH2 RP# Low to Reset during Program 3 12 s 1, 2 100 ns NOTES: 1. If tPLPH is < 100 ns the device may still reset but this is not guaranteed. 2. If RP# is asserted while a Block Erase or Word Program operation is not executing, the reset will complete within 100 ns. 3. Sampled, but not 100% tested. Figure 8. Reset Operations Waveforms RP# (P) VIH VIL t PLPH (A) Reset during Read Mode t PHQV t PHWL t PHEL Abort Complete t PLRH RP# (P) VIH t PHQV t PHWL t PHEL V IL t PLPH (B) Reset during Program or Block Erase, t PLPH < t PLRH Abort Deep Complete PowerDown RP# (P) VIH V IL t PLRH t PHQV t PHWL t PHEL t PLPH (C) Reset Program or Block Erase, t PLPH > t PLRH Datasheet 39 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 5.5 AC I/O Test Conditions Figure 9. AC Input/Output Reference Waveform VCCQ VCCQ /2 Input Test Points VCCQ/2 Output 0V NOTE: Input timing begins, and output timing ends, at VCCQ/2. Input rise and fall times (10% to 90%) < 5 ns. Worst case speed conditions are when VCC = VCCMin. Figure 10. Transient Equivalent Testing Load Circuit VCCQ R1 Device Under Test Out CL R2 NOTE: See Table 17 for component values. Table 22. Test Configuration Component Values for Worst Case Speed Conditions Test Configuration VCCQMin Standard Test CL (pF) R1 (k) R2 (k) 50 25 25 NOTE: CL includes jig capacitance. 5.6 Device Capacitance TA = 25 C, f = 1 MHz Symbol CIN COUT Parameter Typ Max Unit Condition Input Capacitance 6 8 pF VIN = 0.0 V Output Capacitance 8 12 pF VOUT = 0.0 V Sampled, not 100% tested. F. 40 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 6.0 Reset Operations Figure 11. AC Waveform: Deep Power-Down/Reset Operation RP# (P) VIH VIL t PLPH (A) Reset during Read Mode t PHQV t PHWL t PHEL Abort Complete t PLRH RP# (P) VIH t PHQV t PHWL t PHEL V IL t PLPH (B) Reset during Program or Block Erase, t PLPH < t PLRH Abort Deep Complete PowerDown RP# (P) VIH VIL t PLRH t PHQV t PHWL t PHEL t PLPH (C) Reset Program or Block Erase, t PLPH > t PLRH 0580_09 Reset Specifications VCC = 2.7 V-3.6 V Symbol Parameter Notes Unit Min tPLPH RP# Low to Reset during Read (If RP# is tied to VCC, this specification is not applicable) 1,2 tPLRH RP# Low to Reset during Block Erase or Program 2,3 Max 100 ns 22 s NOTES: 1. If tPLPH is <100 ns the device may still RESET but this is not guaranteed 2. .Sampled, but not 100% tested. 3. If RP# is asserted while a block erase or word program operation is not executing, the reset will complete within 100 ns. Datasheet 41 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 7.0 Ordering Information Figure 12. Ordering Information T E2 8 F 3 2 0 B3 T C7 0 Access Speed (ns) (70, 80, 90, 100, 110) Package TE = 48-Lead TSOP GT = 48-Ball BGA* CSP GE = VF BGA CSP Lithography Not Present = 0.4 m A = 0.25 m C = 0.18 m D = 0.13 m Product line designator for all Intel(R) Flash products T = Top Blocking B = Bottom Blocking Device Density 640 = x16 (64 Mbit) 320 = x16 (32 Mbit) 160 = x16 (16 Mbit) 800 = x16 (8 Mbit) Product Family B3 = 3 Volt Advanced+ Boot Block VCC = 2.7 V-3.6 V VPP = 2.7 V-3.6 V or 11.4 V-12.6 V 016 = x8 (16 Mbit) 008 = x8 (8 Mbit) Table 23. Ordering Information Valid Combinations (Sheet 1 of 2) 40-Lead TSOP 48-Lead TSOP Ext. Temp. 64 Mbit TE28F640B3TC80 TE28F640B3BC80 Ext. Temp. 32 Mbit TE28F320B3TD70 TE28F320B3BD70 TE28F320B3TC70 TE28F320B3BC70 TE28F320B3TC90 TE28F320B3BC90 TE28F320B3TA100 TE28F320B3BA100 TE28F320B3TA110 TE28F320B3BA110 Ext. Temp. 16 Mbit 42 TE28F016B3TA90 TE28F016B3BA90 TE28F016B3TA110 TE28F016B3BA110 TE28F160B3TD70 TE28F160B3BD70 TE28F160B3TC70 TE28F160B3BC70 TE28F160B3TC80 TE28F160B3BC80 TE28F160B3TC90 TE28F160B3BC90 TE28F160B3TA90 TE28F160B3BA90 TE28F160B3TA110 TE28F160B3BA110 48-Ball BGA CSP(1,2) 48-Ball VF BGA GE28F640B3TC80 GE28F640B3BC80 GE28F320B3TD70 GE28F320B3BD70 GE28F320B3TC70 GE28F320B3BC70 GE28F320B3TC90 GE28F320B3BC90 GT28F160B3TA90(3) GT28F160B3BA90(3) GT28F160B3TA110(3) GT28F160B3BA110(3) GE28F160B3TD70 GE28F160B3BD70 GE28F160B3TC70 GE28F160B3BC70 GE28F160B3TC80 GE28F160B3BC80 GE28F160B3TC90 GE28F160B3BC90 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Table 23. Ordering Information Valid Combinations (Sheet 2 of 2) 40-Lead TSOP 48-Lead TSOP Ext. Temp. 8 Mbit TE28F008B3TA90 TE28F008B3BA90 TE28F008B3TA110 TE28F008B3BA110 TE28F800B3TA90 TE28F800B3BA90 TE28F800B3TA110 TE28F800B3BA110 48-Ball BGA CSP(1,2) 48-Ball VF BGA GE28F800B3TA70 GE28F800B3BA70 GE28F008B3TA70 GE28F008B3BA70 GE28F800B3TA90 GE28F800B3BA90 GE28F008B3TA90 GE28F008B3BA90 NOTES: 1. The 48-ball BGA package top side mark reads F160B3. This mark is identical for both x8 and x16 products. All product shipping boxes or trays provide the correct information regarding bus architecture. However, once the devices are removed from the shipping media, it may be difficult to differentiate based on the top side mark. The device identifier (accessible through the Device ID command: see Section 3.2.2 for further details) enables x8 and x16 BGA package product differentiation. 2. The second line of the 48-ball BGA package top side mark specifies assembly codes. For samples only, the first character signifies either "E" for engineering samples or "S" for silicon daisy-chain samples. All other assembly codes without an "E" or "S" as the first character are production units. 3. Intel recommends using .18 m Intel Advanced Boot Block Products. Datasheet 43 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 8.0 Additional Information Order Number Document/Tool 297948 Intel Advanced Boot Block Flash Memory Family Specification Update 292199 AP-641 Achieving Low Power with the 3 Volt Advanced Boot Block Flash Memory 292200 AP-642 Designing for Upgrade to the 3 Volt Advanced Boot Block Flash Memory Note 2 3 Volt Advanced Boot Block Algorithms (`C' and assembly) http://developer.intel.com/design/flash/swtools Contact your Intel Representative 297874 Intel(R) Flash Data Integrator (IFDI) Software Developer's Kit IFDI Interactive: Play with Intel(R) Flash Data Integrator on Your PC NOTES: 1. Please call the Intel Literature Center at (800) 548-4725 to request Intel documentation. International customers should contact their local Intel or distribution sales office. 2. Visit Intel's World Wide Web home page at http://www.Intel.com or http://developer.intel.com for technical documentation and tools. 3. For the most current information on Intel Advanced Boot Block Flash memory and Intel Advanced+ Boot Block Flash memory, visit our microsite at http://developer.intel.com/design/flash/abblock. 44 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix A Write State Machine Current/Next States Command Input (and Next State) Current State SR.7 Data When Read Read Array (FFH) Program Setup (10/ 40H) Erase Setup (20H) Read Array "1" Array Read Array Program Setup Erase Setup Read Status "1" Status Read Array Program Setup Read Identifier "1" Identifier Read Array Program Setup Prog. Setup "1" Status Program (continue) "0" Status Program Suspend to Read Status "1" Status Prog. Susp. to Read Array Program Suspend to Read Array Program (continue) Program Susp. to Read Array Program (continue) Prog. Susp. to Read Status Prog. Susp. to Read Array Prog. Susp. to Read Identifier Program Suspend to Read Array "1" Array Prog. Susp. to Read Array Program Suspend to Read Array Program (continue) Program Susp. to Read Array Program (continue) Prog. Susp. to Read Status Prog. Sus. to Read Array Prog. Susp. to Read Identifier Prog. Susp. to Read Identifier "1" Identifier Prog. Susp. to Read Array Program Suspend to Read Array Program (continue) Program Susp. to Read Array Program (continue) Prog. Susp. to Read Status Prog. Sus. to Read Array Prog. Susp. to Read Identifier Program (complete) "1" Status Read Array Read Status Read Array Read Identifier Erase Setup "1" Status Erase Cmd. Error "1" Status Erase (continue) "0" Status Erase Suspend to Status "1" Status Erase Susp. to Read Array Program Setup Erase Susp. to Read Array Erase Erase Susp. to Read Array Erase Erase Susp. to Read Status Erase Susp. to Read Array Ers. Susp. to Read Identifier Erase Susp. to Read Array "1" Array Erase Susp. to Read Array Program Setup Erase Susp. to Read Array Erase Erase Susp. to Read Array Erase Erase Susp. to Read Status Erase Susp. to Read Array Ers. Susp. to Read Identifier Erase Susp. to Read Identifier "1" Identifier Erase Susp. to Read Array Program Setup Erase Susp. to Read Array Erase Erase Susp. to Read Array Erase Erase Susp. to Read Status Erase Susp. to Read Array Ers. Susp. to Read Identifier Erase (complete) "1" Status Read Array Program Setup Erase Setup Read Status Read Array Read Identifier Datasheet Erase Confirm (D0H) Prog/Ers Suspend (B0H) Prog/Ers Resume (D0H) Read Status (70H) Clear Status (50H) Read Identifier. (90H) Read Array Read Status Read Array Read Identifier Erase Setup Read Array Read Status Read Array Read Identifier Erase Setup Read Array Read Status Read Array Read Identifier Program (Command Input = Data to be Programmed) Prog. Sysop. to Rd. Status Program (continue) Program Setup Erase Setup Erase Command Error Read Array Program Setup Program (continue) Read Array Erase (continue) Erase Cmd. Error Erase (continue) Erase Command Error Erase Setup Read Array Read Status Erase (continue) Erase Sus. to Read Status Erase (continue) Read Array Read Array Read Identifier 45 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix B Architecture Block Diagram DQ0-DQ15 VCCQ Power Reduction Control Input Buffer Identifier Register Status Register Data Register Output Multiplexer Output Buffer I/O Logic CE# WE# OE# RP# Command User Interface Data Comparator WP# A0-A19 Y-Decoder Y-Gating/Sensing Write State Machine Address Counter 32-KWord Main Block X-Decoder 4-KWord Parameter Block 32-KWord Main Block Address Latch 4-KWord Parameter Block Input Buffer Program/Erase Voltage Switch VPP VCC GND 0580-C1 46 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix C Word-Wide Memory Map Diagrams 16-Mbit and 32-Mbit Word-Wide Memory Addressing Top Boot Size (KW) 4 4 4 4 4 4 4 4 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 16 Mbit Bottom Boot 32 Mbit FF000-FFFFF 1FF000-1FFFFF FE000-FEFFF 1FE000-1FEFFF FD000-FDFFF 1FD000-1FDFFF FC000-FCFFF 1FC000-1FCFFF FB000-FBFFF 1FB000-1FBFFF FA000-FAFFF 1FA000-1FAFFF F9000-F9FFF 1F9000-1F9FFF F8000-F8FFF 1F8000-1F8FFF F0000-F7FFF 1F0000-1F7FFF E8000-EFFFF 1E8000-1EFFFF E0000-E7FFF 1E0000-1E7FFF D8000-DFFFF 1D8000-1DFFFF D0000-D7FFF 1D0000-1D7FFF C8000-CFFFF 1C8000-1CFFFF C0000-C7FFF 1C0000-1C7FFF B8000-BFFFF 1B8000-1BFFFF B0000-B7FFF 1B0000-1B7FFF A8000-AFFFF 1A8000-1AFFFF A0000-A7FFF 1A0000-1A7FFF 98000-9FFFF 198000-19FFFF 90000-97FFF 190000-197FFF 88000-8FFFF 188000-18FFFF 80000-87FFF 180000-187FFF 78000-7FFFF 178000-17FFFF 70000-77FFF 170000-177FFF 68000-6FFFF 168000-16FFFF 60000-67FFF 160000-167FFF 58000-5FFFF 158000-15FFFF 50000-57FFF 150000-157FFF 48000-4FFFF 148000-14FFFF 40000-47FFF 140000-147FFF 38000-3FFFF 138000-13FFFF 30000-37FFF 130000-137FFF 28000-2FFFF 128000-12FFFF 20000-27FFF 120000-127FFF 18000-1FFFF 118000-11FFFF 10000-17FFF 110000-117FFF 08000-0FFFF 108000-10FFFF 00000-07FFF 100000-107FFF This column continues on next page Datasheet Size (KW) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 8 Mbit 16 Mbit 32 Mbit 1F8000-1FFFFF 1F0000-1F7FFF 1E8000-1EFFFF 1E0000-1E7FFF 1D8000-1DFFFF 1D0000-1D7FFF 1C8000-1CFFFF 1C0000-1C7FFF 1B8000-1BFFFF 1B0000-1B7FFF 1A8000-1AFFFF 1A0000-1A7FFF 198000-19FFFF 190000-197FFF 188000-18FFFF 180000-187FFF 178000-17FFFF 170000-177FFF 168000-16FFFF 160000-167FFF 158000-15FFFF 150000-157FFF 148000-14FFFF 140000-147FFF 138000-13FFFF 130000-137FFF 128000-12FFFF 120000-127FFF 118000-11FFFF 110000-117FFF 108000-10FFFF 100000-107FFF F8000-FFFFF 0F8000-0FFFFF F0000-F7FFF 0F0000-0F7FFF E8000-EFFFF 0E8000-0EFFFF E0000-E7FFF 0E0000-0E7FFF D8000-DFFFF 0D8000-0DFFFF D0000-D7FFF 0D0000-0D7FFF C8000-CFFFF 0C8000-0CFFFF This column continues on next page 47 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 16-Mbit and 32-Mbit Word-Wide Memory Addressing (Continued) Top Boot Size (KW) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 48 16 Mbit Bottom Boot 32 Mbit Size (KW) 16 Mbit 32 Mbit 0F8000-0FFFFF 0F0000-0F7FFF 0E8000-0EFFFF 0E0000-0E7FFF 0D8000-0DFFFF 0D0000-0D7FFF 0C8000-0CFFFF 0C0000-0C7FFF 0B8000-0BFFFF 0B0000-0B7FFF 0A8000-0AFFFF 0A0000-0A7FFF 098000-09FFFF 090000-097FFF 088000-08FFFF 080000-087FFF 078000-07FFFF 070000-077FFF 068000-06FFFF 060000-067FFF 058000-05FFFF 050000-057FFF 048000-04FFFF 040000-047FFF 038000-03FFFF 030000-037FFF 028000-02FFFF 020000-027FFF 018000-01FFFF 010000-017FFF 008000-00FFFF 000000-007FFF 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 4 4 4 4 4 4 4 4 C0000-C7FFF B8000-BFFFF B0000-B7FFF A8000-AFFFF A0000-A7FFF 98000-9FFFF 90000-97FFF 88000-8FFFF 80000-87FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF 0C0000-0C7FFF 0B8000-0BFFFF 0B0000-0B7FFF 0A8000-0AFFFF 0A0000-0A7FFF 098000-09FFFF 090000-097FFF 088000-08FFFF 080000-087FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 4-Mbit and 8-Mbit Word-Wide Memory Addressing Top Boot Size (KW) 4 4 4 4 4 4 4 4 32 32 32 32 32 32 32 Size (KW) 4 Mbit 3F000-3FFFF 3E000-3EFFF 3D000-3DFFF 3C000-3CFFF 3B000-3BFFF 3A000-3AFFF 39000-39FFF 38000-38FFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 00000-07FFF Datasheet Bottom Boot 7F000-7FFFF 7E000-7EFFF 7D000-7DFFF 7C000-7CFFF 7B000-7BFFF 7A000-7AFFF 79000-79FFF 78000-78FFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 00000-07FFF 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 4 4 4 4 4 4 4 4 4 Mbit 8 Mbit 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF 49 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing Top Boot Size (KW) 16 Mbit 4 4 4 4 4 4 4 4 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 FF000-FFFFF FE000-FEFFF FD000-FDFFF FC000-FCFFF FB000-FBFFF FA000-FAFFF F9000-F9FFF F8000-F8FFF F0000-F7FFF E8000-EFFFF E0000-E7FFF D8000-DFFFF D0000-D7FFF C8000-CFFFF C0000-C7FFF B8000-BFFFF B0000-B7FFF A8000-AFFFF A0000-A7FFF 98000-9FFFF 90000-97FFF 88000-8FFFF 80000-87FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 00000-07FFF 50 32 Mbit Bottom Boot 64 Mbit 1FF000-1FFFFF 3FF000-3FFFFF 1FE000-1FEFFF 3FE000-3FEFFF 1FD000-1FDFFF 3FD000-3FDFFF 1FC000-1FCFFF 3FC000-3FCFFF 1FB000-1FBFFF 3FB000-3FBFFF 1FA000-1FAFFF 3FA000-3FAFFF 1F9000-1F9FFF 3F9000-3F9FFF 1F8000-1F8FFF 3F8000-3F8FFF 1F0000-1F7FFF 3F0000-3F7FFF 1E8000-1EFFFF 3E8000-3EFFFF 1E0000-1E7FFF 3E0000-3E7FFF 1D8000-1DFFFF 3D8000-3DFFFF 1D0000-1D7FFF 3D0000-3D7FFF 1C8000-1CFFFF 3C8000-3CFFFF 1C0000-1C7FFF 3C0000-3C7FFF 1B8000-1BFFFF 3B8000-3BFFFF 1B0000-1B7FFF 3B0000-3B7FFF 1A8000-1AFFFF 3A8000-3AFFFF 1A0000-1A7FFF 3A0000-3A7FFF 198000-19FFFF 398000-39FFFF 190000-197FFF 390000-397FFF 188000-18FFFF 388000-38FFFF 180000-187FFF 380000-387FFF 178000-17FFFF 378000-37FFFF 170000-177FFF 370000-377FFF 168000-16FFFF 368000-36FFFF 160000-167FFF 360000-367FFF 158000-15FFFF 358000-35FFFF 150000-157FFF 350000-357FFF 148000-14FFFF 348000-34FFFF 140000-147FFF 340000-347FFF 138000-13FFFF 338000-33FFFF 130000-137FFF 330000-337FFF 128000-12FFFF 328000-32FFFF 120000-127FFF 320000-327FFF 118000-11FFFF 318000-31FFFF 110000-117FFF 310000-317FFF 108000-10FFFF 308000-30FFFF 100000-107FFF 300000-307FFF 0F8000-0FFFFF 2F8000-2FFFFF 0F0000-0F7FFF 2F0000-2F7FFF 0E8000-0EFFFF 2E8000-2EFFFF 0E0000-0E7FFF 2E0000-2E7FFF 0D8000-0DFFFF 2D8000-2DFFFF 0D0000-0D7FFF 2D0000-2D7FFF 0C8000-0CFFFF 2C8000-2CFFFF 0C0000-0C7FFF 2C0000-2C7FFF 0B8000-0BFFFF 2B8000-2BFFFF 0B0000-0B7FFF 2B0000-2B7FFF This column continues on next page Size (KW) 16 Mbit 32 Mbit 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 64 Mbit 3F8000-3FFFFF 3F0000-3F7FFF 3E8000-3EFFFF 3E0000-3E7FFF 3D8000-3DFFFF 3D0000-3D7FFF 3C8000-3CFFFF 3C0000-3C7FFF 3B8000-3BFFFF 3B0000-3B7FFF 3A8000-3AFFFF 3A0000-3A7FFF 398000-39FFFF 390000-397FFF 388000-38FFFF 380000-387FFF 378000-37FFFF 370000-377FFF 368000-36FFFF 360000-367FFF 358000-35FFFF 350000-357FFF 348000-34FFFF 340000-347FFF 338000-33FFFF 330000-337FFF 328000-32FFFF 320000-327FFF 318000-31FFFF 310000-317FFF 308000-30FFFF 300000-307FFF 2F8000-2FFFFF 2F0000-2F7FFF 2E8000-2EFFFF 2E0000-2E7FFF 2D8000-2DFFFF 2D0000-2D7FFF 2C8000-2CFFFF 2C0000-2C7FFF 2B8000-2BFFFF 2B0000-2B7FFF 2A8000-2AFFFF 2A0000-2A7FFF 298000-29FFFF 290000-297FFF 288000-28FFFF 280000-287FFF 278000-27FFFF This column continues on next page Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing (Continued) Top Boot Size (KW) 16 Mbit 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 Datasheet 32 Mbit 0A8000-0AFFFF 0A0000-0A7FFF 098000-09FFFF 090000-097FFF 088000-08FFFF 080000-087FFF 078000-07FFFF 070000-077FFF 068000-06FFFF 060000-067FFF 058000-05FFFF 050000-057FFF 048000-04FFFF 040000-047FFF 038000-03FFFF 030000-037FFF 028000-02FFFF 020000-027FFF 018000-01FFFF 010000-017FFF 008000-00FFFF 000000-007FFF Bottom Boot 64 Mbit 2A8000-2AFFFF 2A0000-2A7FFF 298000-29FFFF 290000-297FFF 288000-28FFFF 280000-287FFF 278000-27FFFF 270000-277FFF 268000-26FFFF 260000-267FFF 258000-25FFFF 250000-257FFF 248000-24FFFF 240000-247FFF 238000-23FFFF 230000-237FFF 228000-22FFFF 220000-227FFF 218000-21FFFF 210000-217FFF 208000-21FFFF 200000-207FFF 1F8000-1FFFFF 1F0000-1F7FFF 1E8000-1EFFFF 1E0000-1E7FFF 1D8000-1DFFFF 1D0000-1D7FFF 1C8000-1CFFFF 1C0000-1C7FFF 1B8000-1BFFFF 1B0000-1B7FFF 1A8000-1AFFFF 1A0000-1A7FFF 198000-19FFFF 190000-197FFF 188000-18FFFF 180000-187FFF 178000-17FFFF 170000-177FFF 168000-16FFFF 160000-167FFF 158000-15FFFF 150000-157FFF 148000-14FFFF 140000-147FFF 138000-13FFFF 130000-137FFF 128000-12FFFF 120000-127FFF 118000-11FFFF 110000-117FFF 108000-10FFFF 100000-107FFF This column continues on next page Size (KW) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 16 Mbit 32 Mbit 1F8000-1FFFFF 1F0000-1F7FFF 1E8000-1EFFFF 1E0000-1E7FFF 1D8000-1DFFFF 1D0000-1D7FFF 1C8000-1CFFFF 1C0000-1C7FFF 1B8000-1BFFFF 1B0000-1B7FFF 1A8000-1AFFFF 1A0000-1A7FFF 198000-19FFFF 190000-197FFF 188000-18FFFF 180000-187FFF 178000-17FFFF 170000-177FFF 168000-16FFFF 160000-167FFF 158000-15FFFF 150000-157FFF 148000-14FFFF 140000-147FFF 138000-13FFFF 130000-137FFF 128000-12FFFF 120000-127FFF 118000-11FFFF 110000-117FFF 108000-10FFFF 100000-107FFF F8000-FFFFF F8000-FFFFF F0000-F7FFF F0000-F7FFF E8000-EFFFF E8000-EFFFF E0000-E7FFF E0000-E7FFF D8000-DFFFF D8000-DFFFF D0000-D7FFF D0000-D7FFF C8000-CFFFF C8000-CFFFF This column continues on next page 64 Mbit 270000-277FFF 268000-26FFFF 260000-267FFF 258000-25FFFF 250000-257FFF 248000-24FFFF 240000-247FFF 238000-23FFFF 230000-237FFF 228000-22FFFF 220000-227FFF 218000-21FFFF 210000-217FFF 208000-20FFFF 200000-207FFF 1F8000-1FFFFF 1F0000-1F7FFF 1E8000-1EFFFF 1E0000-1E7FFF 1D8000-1DFFFF 1D0000-1D7FFF 1C8000-1CFFFF 1C0000-1C7FFF 1B8000-1BFFFF 1B0000-1B7FFF 1A8000-1AFFFF 1A0000-1A7FFF 198000-19FFFF 190000-197FFF 188000-18FFFF 180000-187FFF 178000-17FFFF 170000-177FFF 168000-16FFFF 160000-167FFF 158000-15FFFF 150000-157FFF 148000-14FFFF 140000-147FFF 138000-13FFFF 130000-137FFF 128000-12FFFF 120000-127FFF 118000-11FFFF 110000-117FFF 108000-10FFFF 100000-107FFF F8000-FFFFF F0000-F7FFF E8000-EFFFF E0000-E7FFF D8000-DFFFF D0000-D7FFF C8000-CFFFF 51 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 16-Mbit, 32-Mbit, and 64-Mbit Word-Wide Memory Addressing (Continued) Top Boot Size (KW) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 52 16 Mbit 32 Mbit Bottom Boot 64 Mbit Size (KW) 16 Mbit 32 Mbit 64 Mbit 0F8000-0FFFFF 0F0000-0F7FFF 0E8000-0EFFFF 0E0000-0E7FFF 0D8000-0DFFFF 0D0000-0D7FFF 0C8000-0CFFFF 0C0000-0C7FFF 0B8000-0BFFFF 0B0000-0B7FFF 0A8000-0AFFFF 0A0000-0A7FFF 098000-09FFFF 090000-097FFF 088000-08FFFF 080000-087FFF 078000-07FFFF 070000-077FFF 068000-06FFFF 060000-067FFF 058000-05FFFF 050000-057FFF 048000-04FFFF 040000-047FFF 038000-03FFFF 030000-037FFF 028000-02FFFF 020000-027FFF 018000-01FFFF 010000-017FFF 008000-00FFFF 000000-007FFF 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 4 4 4 4 4 4 4 4 C0000-C7FFF B8000-BFFFF B0000-B7FFF A8000-AFFFF A0000-A7FFF 98000-9FFFF 90000-97FFF 88000-8FFFF 80000-87FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF C0000-C7FFF B8000-BFFFF B0000-B7FFF A8000-AFFFF A0000-A7FFF 98000-9FFFF 90000-97FFF 88000-8FFFF 80000-87FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF C0000-C7FFF B8000-BFFFF B0000-B7FFF A8000-AFFFF A0000-A7FFF 98000-9FFFF 90000-97FFF 88000-8FFFF 80000-87FFF 78000-7FFFF 70000-77FFF 68000-6FFFF 60000-67FFF 58000-5FFFF 50000-57FFF 48000-4FFFF 40000-47FFF 38000-3FFFF 30000-37FFF 28000-2FFFF 20000-27FFF 18000-1FFFF 10000-17FFF 08000-0FFFF 07000-07FFF 06000-06FFF 05000-05FFF 04000-04FFF 03000-03FFF 02000-02FFF 01000-01FFF 00000-00FFF Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix D Byte-Wide Memory Map Diagrams 8-Mbit and 16-Mbit Byte-Wide Byte-Wide Memory Addressing Top Boot Size (KB) 8 Mbit 8 8 8 8 8 8 8 8 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 FE000-FFFFF FC000-FDFFF FA000-FBFFF F8000-F9FFF F6000-F7FFF F4000-F5FFF F2000-F3FFF F0000-F1FFF E0000-EFFFF D0000-DFFFF C0000-CFFFF B0000-BFFFF A0000-AFFFF 90000-9FFFF 80000-8FFFF 70000-7FFFF 60000-6FFFF 50000-5FFFF 40000-4FFFF 30000-3FFFF 20000-2FFFF 10000-1FFFF 00000-0FFFF Bottom Boot 16 Mbit 1FE000-1FFFFF 1FC000-1FDFFF 1FA000-1FBFFF 1F8000-1F9FFF 1F6000-1F7FFF 1F4000-1F5FFF 1F2000-1F3FFF 1F0000-1F1FFF 1E0000-1EFFFF 1D0000-1DFFFF 1C0000-1CFFFF 1B0000-1BFFFF 1A0000-1AFFFF 190000-19FFFF 180000-18FFFF 170000-17FFFF 160000-16FFFF 150000-15FFFF 140000-14FFFF 130000-13FFFF 120000-12FFFF 110000-11FFFF 100000-10FFFF 0F0000-0FFFFF 0E0000-0EFFFF 0D0000-0DFFFF 0C0000-0CFFFF 0B0000-0BFFFF 0A0000-0AFFFF 090000-09FFFF 080000-08FFFF 070000-07FFFF 060000-06FFFF 050000-05FFFF 040000-04FFFF 030000-03FFFF 020000-02FFFF 010000-01FFFF 000000-00FFFF This column continues on next page Datasheet Size (KB) 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 8 Mbit 16 Mbit 1F0000-1FFFFF 1E0000-1EFFFF 1D0000-1DFFFF 1C0000-1CFFFF 1B0000-1BFFFF 1A0000-1AFFFF 190000-19FFFF This column continues on next page 53 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 8-Mbit and 16-Mbit Byte-Wide Memory Addressing (Continued) Top Boot Size (KB) 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 54 8 Mbit Bottom Boot 16 Mbit Size (KB) 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 8 8 8 8 8 8 8 8 8 Mbit 16 Mbit F0000-FFFFF E0000-EFFFF D0000-DFFFF C0000-CFFFF B0000-BFFFF A0000-AFFFF 90000-9FFFF 80000-8FFFF 70000-7FFFF 60000-6FFFF 50000-5FFFF 40000-4FFFF 30000-3FFFF 20000-2FFFF 10000-1FFFF 0E000-0FFFF 0C000-0DFFF 0A000-0BFFF 08000-09FFF 06000-07FFF 04000-05FFF 02000-03FFF 00000-01FFF 180000-18FFFF 170000-17FFFF 160000-16FFFF 150000-15FFFF 140000-14FFFF 130000-13FFFF 120000-12FFFF 110000-11FFFF 100000-10FFFF 0F0000-0FFFFF 0E0000-0EFFFF 0D0000-0DFFFF 0C0000-0CFFFF 0B0000-0BFFFF 0A0000-0AFFFF 090000-09FFFF 080000-08FFFF 070000-07FFFF 060000-06FFFF 050000-05FFFF 040000-04FFFF 030000-03FFFF 020000-02FFFF 010000-01FFFF 00E000-00FFFF 00C000-00DFFF 00A000-00BFFF 008000-009FFF 006000-007FFF 004000-005FFF 002000-003FFF 000000-001FFF Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 4-Mbit Byte-Wide Memory Addressing Top Boot Bottom Boot Size (KB) 4 Mbit Size (KB) 4 Mbit 8 8 8 8 8 8 8 8 64 64 64 64 64 64 64 7E000-7FFFF 7C000-7DFFF 7A000-7BFFF 78000-79FFF 76000-77FFF 74000-75FFF 72000-73FFF 70000-71FFF 60000-6FFFF 50000-5FFFF 40000-4FFFF 30000-3FFFF 20000-2FFFF 10000-1FFFF 00000-0FFFF 64 64 64 64 64 64 64 8 8 8 8 8 8 8 8 70000-7FFFF 60000-6FFFF 50000-5FFFF 40000-4FFFF 30000-3FFFF 20000-2FFFF 10000-1FFFF 0E000-0FFFF 0C000-0DFFF 0A000-0BFFF 08000-09FFF 06000-07FFF 04000-05FFF 02000-03FFF 00000-01FFF Datasheet 55 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix E Program and Erase Flowcharts Figure 13. Program Flowchart Start Write 40H Bus Operation Command Write Program Setup Write Program Program Address/Data Data = 40H Data = Data to Program Addr = Location to Program Status Register Data Toggle CE# or OE# to Update Status Register Data Read Read Status Register Check SR.7 1 = WSM Ready 0 = WSM Busy Standby Repeat for subsequent programming operations. No SR.7 = 1? Comments SR Full Status Check can be done after each program or after a sequence of program operations. Yes Full Status Check if Desired Write FFH after the last program operation to reset device to read array mode. Program Complete FULL STATUS CHECK PROCEDURE Read Status Register Data (See Above) Bus Operation 1 SR.3 = 0 VPP Range Error Programming Error 0 1 SR.1 = Comments Standby Check SR.3 1 = VPP Low Detect Standby Check SR.4 1 = VPP Program Error Standby Check SR.1 1 = Attempted Program to Locked Block - Program Aborted 1 SR.4 = Command SR.3 MUST be cleared, if set during a program attempt, before further attempts are allowed by the Write State Machine. Attempted Program to Locked Block - Aborted SR.1, SR.3 and SR.4 are only cleared by the Clear Staus Register Command, in cases where multiple bytes are programmed before full status is checked. 0 Program Successful If an error is detected, clear the status register before attempting retry or other error recovery. 0580_E1 56 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 14. Program Suspend/Resume Flowchart Start Bus Operation Command Write Program Suspend Data = B0H Addr = X Write Read Status Data = 70H Addr = X Comments Write B0H Status Register Data Toggle CE# or OE# to Update Status Register Data Addr = X Write 70H Read Read Status Register 0 SR.7 = 1 Standby Check SR.7 1 = WSM Ready 0 = WSM Busy Standby Check SR.2 1 = Program Suspended 0 = Program Completed Write 0 SR.2 = Read Array Program Completed Read array data from block other than the one being programmed. Read 1 Write FFH Write Data = FFH Addr = X Program Resume Data = D0H Addr = X Read Array Data No Done Reading Yes Write D0H Write FFH Program Resumed Read Array Data 0580_E2 Datasheet 57 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 15. Block Erase Flowchart Start Bus Operation Write 20H Write D0H and Block Address Command Write Erase Setup Write Erase Confirm Data = D0H Addr = Within Block to Be Erased Status Register Data Toggle CE# or OE# to Update Status Register Data Read Read Status Register Suspend Erase Loop 0 SR.7 = No Suspend Erase Comments Data = 20H Addr = Within Block to Be Erased Check SR.7 1 = WSM Ready 0 = WSM Busy Standby Yes Repeat for subsequent block erasures. Full Status Check can be done after each block erase or after a sequence of block erasures. 1 Full Status Check if Desired Write FFH after the last write operation to reset device to read array mode. Block Erase Complete FULL STATUS CHECK PROCEDURE Read Status Register Data (See Above) Bus Operation 1 SR.3 = 0 1 Command Sequence Error 0 1 SR.5 = Block Erase Error Comments Standby Check SR.3 1 = V PP Low Detect Standby Check SR.4,5 Both 1 = Command Sequence Error Standby Check SR.5 1 = Block Erase Error Standby Check SR.1 1 = Attempted Erase of Locked Block - Erase Aborted VPP Range Error SR.4,5 = Command SR. 1 and 3 MUST be cleared, if set during an erase attempt, before further attempts are allowed by the Write State Machine. 0 1 SR.1 = 0 Attempted Erase of Locked Block - Aborted SR.1, 3, 4, 5 are only cleared by the Clear Staus Register Command, in cases where multiple bytes are erased before full status is checked. If an error is detected, clear the status register before attempting retry or other error recovery. Block Erase Successful 0580_E3 58 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 16. Erase Suspend/Resume Flowchart Start Bus Operation Command Comments Write Erase Suspend Data = B0H Addr = X Write Read Status Data = 70H Addr = X Write B0H Status Register Data Toggle CE# or OE# to Update Status Register Data Addr = X Write 70H Read Read Status Register 0 SR.7 = 1 Standby Check SR.7 1 = WSM Ready 0 = WSM Busy Standby Check SR.6 1 = Erase Suspended 0 = Erase Completed Write 0 SR.6 = Read Array Erase Completed Read array data from block other than the one being erased. Read 1 Write FFH Write Data = FFH Addr = X Erase Resume Data = D0H Addr = X Read Array Data No Done Reading Yes Write D0H Write FFH Erase Resumed Read Array Data 0580_E4 Datasheet 59 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Appendix F Mechanical Specifications Figure 17. BGA* and VF BGA Package Drawing & Dimensions R0 Ball A1 Corner D 1 E 2 3 4 S1 5 6 7 8 8 A A B B C C D D E E F F 7 6 5 4 3 Ball A1 Corner S2 2 1 e b Top View - Bump Side down Bottom View -Bump side up A 1 A2 A Seating Y Plan Side View Note: Drawing not to scale Dimensions Package Height Ball Height Package Body Thickness Ball (Lead) Width Package Body Length 8M (.25) Package Body Length 16M (.25/.18/.13) 32M (.25/.18/.13) Package Body Length 64M (.18) Package Body Width 8M (.25) Package Body Width 16M (.25/.18/.13) 32M (.18/.13) Package Body Width 32M (.25) Package Body Width 64M (.18) Pitch Ball (Lead) Count 8M, 16M Ball (Lead) Count 32M Ball (Lead) Count 64M Seating Plane Coplanarity Corner to Ball A1 Distance Along D 8M (.25) Corner to Ball A1 Distance Along D 16M (.25/.18/.13) 32M (.18/.13) Corner to Ball A1 Distance Along D 64M (.18) Corner to Ball A1 Distance Along E 8M (.25) Corner to Ball A1 Distance Along E 16M (.25/.18/.13) 32M (.18/.13) Corner to Ball A1 Distance Along E 32M (.25) Corner to Ball A1 Distance Along E 64M (.18) 60 Symbol A A1 A2 b D D D E E E E e N N N Y S1 S1 S1 S2 S2 S2 S2 Min Millimeters Nom Max 1.000 0.150 0.325 7.810 7.186 7.600 6.400 6.864 10.750 8.900 1.230 0.918 1.125 1.275 1.507 3.450 2.525 Min Inches Nom Max 0.0394 0.0059 0.665 0.375 7.910 7.286 7.700 6.500 6.964 10.850 9.000 0.750 46 47 48 1.330 1.018 1.225 1.375 1.607 3.550 2.625 0.0128 0.0262 0.0148 0.425 8.010 7.386 7.800 6.600 7.064 10.860 9.100 0.2829 0.2992 0.2520 0.2702 0.4232 0.3504 0.2868 0.3031 0.2559 0.2742 0.4272 0.3543 0.0295 46 47 48 0.100 1.430 1.118 1.325 1.475 1.707 3.650 2.725 0.0484 0.0361 0.0443 0.0502 0.0593 0.1358 0.0994 0.0524 0.0401 0.0482 0.0541 0.0633 0.1398 0.1033 0.0167 0.2908 0.3071 0.2598 0.2781 0.4276 0.3583 0.0039 0.0563 0.0440 0.0522 0.0581 0.0672 0.1437 0.1073 Datasheet 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 18. TSOP Package Drawing & Dimensions Z A2 See Notes 1, 2, 3 and 4 Pin 1 e See Detail B E Y D1 A1 D Seating Plane See Detail A A Detail A Detail B C b 0 L A5568-02 Dimensions Family: Thin Small Out -Line Package Symbol Millimeters Min Package Height 1. 2. 3. 4. Datasheet Nom A Inches Max Notes Min Nom 1.200 Max Standoff A1 0.050 Package Body Thickness A2 0.950 1.000 1.050 0.037 0.039 0.041 Lead Width b 0.150 0.200 0.300 0.006 0.008 0.012 0.002 0.100 0.150 Lead Thickness c 0.200 0.004 0.006 0.008 Plastic Body Length D1 18.200 18.400 18.600 0.717 0.724 0.732 Package Body Width E 11.800 12.000 12.200 0.465 0.472 0.480 Lead Pitch e 0.500 Terminal Dimension D 19.800 20.000 20.200 Lead Tip Length L Lead Count N Lead Tip Angle O Seating Plane Coplanarity Y Lead to Package Offset Z 0.500 Notes 0.047 0.600 0.0197 0.780 0.787 0.795 0.700 0.020 0.024 0.028 5 0 3 5 0.006 0.010 0.014 48 0 3 0.150 0.250 48 0.100 0.350 0.004 One dimple on package denotes Pin 1. If two dimples, then the larger dimple denotes Pin 1. Pin 1 will always be in the upper left corner of the package, in reference to the product mark. Pin 1 will always supersede above pin one notes. 61 28F008/800B3, 28F016/160B3, 28F320B3, 28F640B3 Figure 19. Easy BGA Package Drawing & Dimension Ball A1 Corner D 1 E 2 3 4 Ball A1 Corner S1 5 6 7 8 8 A A B B C C D D E E F F G G H H 7 6 5 4 3 2 1 S2 b e Top View - Ball side down Bottom View - Ball Side Up A1 A2 A Seating Y Plane Side View Note: Drawing not to scale Dimensions Table Package Height Ball Height Package Body Thickness Ball (Lead) Width Package Body Width Package Body Length Pitch Ball (Lead) Count Seating Plane Coplanarity Corner to Ball A1 Distance Along D Corner to Ball A1 Distance Along E Symbol A A1 A2 b D E [e] N Y S1 S2 Millimeters Min Nom Max 1.200 Notes 0.250 0.330 9.900 12.900 1.400 2.900 Inches Min Nom Max 0.0472 0.0098 0.780 0.430 10.000 13.000 1.000 64 1.500 3.000 0.530 10.100 13.100 1 1 0.0130 0.3898 0.5079 0.100 1.600 3.100 1 1 0.0551 0.1142 0.0307 0.0169 0.3937 0.5118 0.0394 64 0.0591 0.1181 0.0209 0.3976 0.5157 0.0039 0.0630 0.1220 Note: (1) Package dimensions are for reference only. These dimensions are estimates based on die size, and are subject to change. 62 Datasheet