Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com90
Altech’s Eurostrips are safe, econom-
ical and meet worldwide standards.
They are a cost-effective alternative
to barrier strips that require labor-
intensive wire lugs and they reduce
the number of electrical connections
in circuits.
Eurostrips feature tubular screw
clamps, wire protectors, and are
ready for immediate wire hookup.
Eurostrips are ideal in small spaces,
which means more room for other
components or reduced enclosure
size. Free float or mount them onto
any panel. They are available in
easy-to-cut 12-pole strips or pre-cut.
Feed-Through Eurostrips are supplied
with wire protectors. Offered with
flat bases or standoff feet, they are
molded of self-extinguishing
polyamide. Custom imprinting and
marking plates are available.
EUROSTRIPS
®
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 91
EASY MOUNTING SAVES
INSTALLATION TIME
Eurostrips are mounted quickly in pan-
els. Use standard screws or mounting
pins, offered as accessories in this sec-
tion, or leave them free floating to com-
pletely eliminate mounting.
EASY
CONNECTION SAVES
MONEY
What could be easier? Simply strip the
wire insulation, insert the wire and
tighten the screw to achieve a gas-tight,
electrically efficient connection—every
time. Wire lugs are eliminated, saving
material cost and installation time.
EASY MODIFICATION REDUCES
INVENTORY
Offered in easy-to-cut 12-pole strips, they
can also be ordered precut with the required
number of poles.
Polyamide housing can
be cut with a utility knife or hacksaw,
providing flexibility to meet changing
needs. Because standard 12 pole strips
can be so easily cut to the required num-
ber of poles, stocking is simplified and
inventory is minimized.
RELIABLE CONNECTION
EVERY TIME
The basis for the Eurostrip’s reliable con-
nection is a precision machined tubular
screw clamp insert made from highly
conductive copper alloy which is nickel
plated for maximum corrosion resist-
ance. The clamping screw material is
high strength steel to
prevent screw head
breakage or thread
damage. This provides
trouble free opera-
tion. Screws are
electrogalva-
nized and bluechro-
mated to provide cor-
rosion resistance. Optional nickel plated
brass screws may be ordered for highly
corrosive environments or marine appli-
cations.
Standard Eurostrips feature stainless
steel wire protectors. Unlike wire pro-
tectors found in many competitive prod-
ucts which use copper alloy materials,
stainless steel has superior memory
characteristics. Accordingly, the wire
protector will return to its original posi-
tion even after repeated use. This
means trouble-free wire insertion and
quicker reconnections.
HOUSINGS
Eurostrip housings are injection molded
from self-extinguishing polyamide 66/6,
V-O molding material, possessing high
dielectric strength and excellent electri-
cal insulation and temperature resist-
ance. Each housing has been specially
designed to provide creepage and clear-
ance distances to achieve ratings up to
600V. Choose low profile, flat base
housings for minimum clearance appli-
cations (300V) or housings with mount-
ing feet for maximum voltage isolation
(600V).
ACCESSORIES
External jumpers bus potentials
between poles on Eurostrips, eliminat-
ing wire jumpers and reducing wiring
time. Isolation partition increases clear-
ance between adjacent poles and pro-
vides visual separation for more effi-
cient wiring. Mounting pins simplify
installation and mounting of Eurostrips.
Simply drill the mounting hole, position
and install the pin from underneath the
panel. When correct position is
reached, pin will retain terminal to
panel.
Identify circuits and reduce wiring mis-
takes with marking plates. Order plates
imprinted or blank. Position under or on
top of a Eurostrip housing.
Imprinting Eurostrips reduces wiring
errors and helps to identify circuits. Use
Imprinting to mark individual poles
when high quantities are involved or
custom imprints are required.
Eurostrips®
FEED-THROUGH FLAT BASE
Panel Mount
For wire-to-wire connections in
HVAC, appliance, equipment,
power distribution and other
industrial applications with
strict budget and space require-
ments. Easy to use double row
terminal strips are a cost-effec-
tive alternative to barrier strips
or other types of terminal
blocks. Simply strip the wire,
insert and tighten the screw.
Eurostrips feature tubular screw
clamps, with wire protectors,
and recessed metal parts for fin-
ger protection. The stainless
steel wire protectors exhibit
excellent memory and the most
effective connection.
Eurostrips described on this and
the following page are available
with a flat base for minimum
clearance applications. They can
be panel mounted or left to free
float. Offered in easy-to-cut
standard 12-pole strips, they can
also be ordered precut with the
required number of poles.
Tubular screw clamp
Panel mount or free float
Housing material:
- Polyamide 66/6
- V-O flammability
Color: opaque white
Marking plates or factory
imprinted application
10 mm
3.6 mm
6 mm
2.5-4 mm224-10 AWG
400V 300 V
10 A 30 A
0.8 Nm 7.0 lb-in
Cat. No. Std. Pk.
HE4WPR/02 100
HE4WPR/03 100
HE4WPR/04 100
HE4WPR/05 100
HE4WPR/06 50
HE4WPR/07 50
HE4WPR/08 50
HE4WPR/09 50
HE4WPR/10 50
HE4WPR/11 50
HE4WPR/12 50
8 mm
3 mm
5 mm
1-2.5 mm224-12 AWG
400 V 300 V
6 A 20 A
0.5 Nm 4.4 lb-in
Cat. No. Std. Pk.
HE1WPR/02 100
HE1WPR/03 100
HE1WPR/04 100
HE1WPR/05 100
HE1WPR/06 50
HE1WPR/07 50
HE1WPR/08 50
HE1WPR/09 50
HE1WPR/10 50
HE1WPR/11 50
HE1WPR/12 50
HE1 HE4
Pole Spacing
Mounting Hole Diameter
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Other Approvals
No. of Poles
2
3
4
5
6
7
8
9
10
11
12
Flat base with wire protector Flat base with wire protector
Dimensions mm
A=8.0 H= Ø2.8
B=M2.6 I=2.8
C=5.2 J=6.5
D=2.8 K= 6.5
E=Ø3 L=94 (12 pole)
F=Ø5 M= 12.2
G = 8.0 N = 16.2
Dimensions mm
A=10.0 H= Ø3.6
B=M3 I=3.2
C=6.4 J=8.5
D=3.5 K= 7.9
E=Ø3.6 L=117 (12 pole)
F=Ø5.7 M= 14.9
G = 10.0 N = 20.0
E211022 E211022
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com92
Eurostrips®
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 93
12 mm
4.2 mm
7 mm
4-6 mm220-10 AWG
400V 300 V
16 A 40 A
0.8 Nm 7.0 lb-in
Cat. No. Std. Pk.
HE6WPR/02 100
HE6WPR/03 100
HE6WPR/04 100
HE6WPR/05 100
HE6WPR/06 50
HE6WPR/07 50
HE6WPR/08 50
HE6WPR/09 50
HE6WPR/10 25
HE6WPR/11 25
HE6WPR/12 25
HE6
Flat base with wire protector
Dimensions mm
A=12.0 H= Ø4.1
B=M3.5 I=4.0
C=7.7 J=9.5
D=4.3 K= 8.9
E=Ø4.2 L=140 (12 pole)
F=Ø6.3 M= 16.8
G = 12.0 N = 22.6
15 mm
4.3 / 5.7 mm
8.5 mm
6-10 mm218-8 AWG
400V 300 V
25 A 50 A
1.2 Nm 10.6 lb-in
Cat. No. Std. Pk.
HE10WPR/02 50
HE10WPR/03 50
HE10WPR/04 50
HE10WPR/05 50
HE10WPR/06 25
HE10WPR/07 25
HE10WPR/08 25
HE10WPR/09 25
HE10WPR/10 10
HE10WPR/11 10
HE10WPR/12 10
HE10
Flat base with wire protector
Dimensions mm
A=15.0 H= Ø5.0
B=M4 I=4.8
C=9.3 J=11.3
D=5.7 K= 11.6
E=Ø4.3/5.7 L=175 (12 pole)
F=Ø8.2 M= 21.9
G = 15.0 N = 25.1
15 mm
4.3 / 5.7 mm
8.5 mm
10-16 mm218-6 AWG
400 V 300 V
35-63 A 63 A
2.0 Nm 17.7 lb-in
Cat. No. Std. Pk.
HE16WPR/02 50
HE16WPR/03 50
HE16WPR/04 50
HE16WPR/05 50
HE16WPR/06 25
HE16WPR/07 25
HE16WPR/08 25
HE16WPR/09 25
HE16WPR/10 10
HE16WPR/11 10
HE16WPR/12 10
HE16
Flat base with wire protector
Dimensions mm
A=15.0 H= Ø5.6
B=M5 I=4.8
C=9.3 J=11.3
D=5.7 K= 11.6
E=Ø4.3/5.7 L=175 (12 pole)
F=Ø8.2 M= 21.9
G = 15.0 N = 25.1
E211022 E211022 E211022
Eurostrips®
Dimensions mm
A=8.0 I=6.6
B=M2.6 J=6.5
C=5.2 K= 10.3
D=2.8 L=94 (12 pole)
E=Ø3 M= 16
F=Ø5 N = 16.2
G = 8.0 O= 10.1
H=Ø2.8
Dimensions mm
A=10.0 I=6.7
B=M3 J=8.5
C=6.4 K= 12.1
D=3.5 L=117 (12 pole)
E=Ø3.6 M= 19.1
F=Ø5.7 N = 20
G = 10.0 O = 14.0
H=Ø3.6
FEED-THROUGH
STANDOFF FEET
Panel Mount
For wire-to-wire connections in
HVAC, appliance, equipment,
power distribution and other
industrial applications with
restricted budget and space
requirements.
Easy to use feed-through termi-
nal strips are a cost-effective
alternative to barrier strips or
other types of terminal blocks.
Simply strip the wire, insert, and
tighten the screw. Eurostrips
feature tubular screw clamps,
with wire protectors, and
recessed metal parts for finger
protection. The stainless steel
wire protectors exhibit excellent
memory and the most effective
connection.
Eurostrips described on this and
the preceeding page are avail-
able with standoff feet for
increased wiring efficiency.They
can be panel mounted or left to
free float. Offered in easy-to-cut
12-pole strips, they can also be
ordered precut with the
required number of poles.
Tubular screw clamp
Panel mount or free float
Housing material:
- Polyamide 66/6
- V-O flammability
Color: opaque white
Marking plates or
factory imprinted
10 mm
3.6 mm
6 mm
2.5-4 mm224-10 AWG
400 V 600 V
10 A 30 A
0.8 Nm 7.0 lb-in
Cat. No. Std. Pk.
HE4HNWPR/02 100
HE4HNWPR/03 100
HE4HNWPR/04 100
HE4HNWPR/05 100
HE4HNWPR/06 50
HE4HNWPR/07 50
HE4HNWPR/08 50
HE4HNWPR/09 50
HE4HNWPR/10 50
HE4HNWPR/11 50
HE4HNWPR/12 50
HE1H HE4HN
Pole Spacing
Mounting Hole Diameter
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Other Approvals
No. of Poles
2
3
4
5
6
7
8
9
10
11
12
Standoff feet with wire protector Standoff feet with wire protector
8 mm
3 mm
5 mm
1-2.5 mm224-12 AWG
400 V 600 V
6 A 20 A
0.5 Nm 4.4 lb-in
Cat. No. Std. Pk.
HE1HWPR/02 100
HE1HWPR/03 100
HE1HWPR/04 100
HE1HWPR/05 100
HE1HWPR/06 50
HE1HWPR/07 50
HE1HWPR/08 50
HE1HWPR/09 50
HE1HWPR/10 50
HE1HWPR/11 50
HE1HWPR/12 50
E211022 E211022
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com94
Eurostrips®
Dimensions mm
A=12.0 I=9
B=M3.5 J=9.6
C=7.7 K= 13.9
D=4.3 L=140 (12 pole)
E=Ø4.2 M= 21.8
F=Ø6.3 N = 22.6
G = 12.0 O = 15
H=Ø4.1
Dimensions mm
A=15.0 I=10.7
B=M5 J=11.3
C=9.3 K= 17.5
D=5.7 L=175 (12 pole)
E=Ø4.3/5.7 M= 27.8
F=Ø8.2 N = 25.1
G = 15.0 O = 16
H=Ø5.6
Dimensions mm
A=15.0 I=10.7
B=M4 J=11.3
C=9.3 K= 17.5
D=5.7 L=175 (12 pole)
E=Ø4.3/5.7 M= 27.8
F=Ø8.2 N = 25.1
G = 15.0 O = 16
H=Ø5.0
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 95
15 mm
4.3/5.7 mm
8.5 mm
10-16 mm218-6 AWG
400 V 600 V
35-63 A 63 A
2.0 Nm 17.7 lb-in
Cat. No. Std. Pk.
HE16HWPR/02 40
HE16HWPR/03 40
HE16HWPR/04 40
HE16HWPR/05 40
HE16HWPR/06 20
HE16HWPR/07 20
HE16HWPR/08 20
HE16HWPR/09 10
HE16HWPR/10 10
HE16HWPR/11 10
HE16HWPR/12 10
12 mm
4.2 mm
7 mm
4-6 mm220-10 AWG
400 V 600 V
16 A 40 A
0.8 Nm 7.0 lb-in
Cat. No. Std. Pk.
HE6HWPR/02 100
HE6HWPR/03 100
HE6HWPR/04 100
HE6HWPR/05 100
HE6HWPR/06 50
HE6HWPR/07 50
HE6HWPR/08 50
HE6HWPR/09 50
HE6HWPR/10 25
HE6HWPR/11 25
HE6HWPR/12 25
HE6H HE10H
Standoff feet with wire protector Standoff feet with wire protector
15 mm
4.3/5.7 mm
8.5 mm
6-10 mm218-8 AWG
400 V 600 V
25 A 50 A
1.2 Nm 10.6 lb-in
Cat. No. Std. Pk.
HE10HWPR/02 40
HE10HWPR/03 40
HE10HWPR/04 40
HE10HWPR/05 40
HE10HWPR/06 20
HE10HWPR/07 20
HE10HWPR/08 20
HE10HWPR/09 10
HE10HWPR/10 10
HE10HWPR/11 10
HE10HWPR/12 10
HE16H
Standoff feet with wire protector
E211022 E211022 E211022
Eurostrips®
PLUGGABLE
Panel Mount
For wire-to-wire connections in
HVAC, appliance, equipment,
power and other distribution
applications. Pluggable Euro-
strip speed and simplify
replacement of subassemblies,
etc. They reduce downtime and
misconnections.
Two-piece pluggable terminal
strips feature tubular screw
clamps, with recessed metal
parts for finger protection. A
spring loaded contact prevents
inadvertant unplugging.
The headers and plugs are avail-
able with flat base or standoff
feet and can be panel mounted
or free float. Offered in easy-to
cut 12-pole strips, they can also
be orderd precut with the
required number of poles.
Tubular Screw Clamp
Panel Mount or Free Float
Housing material:
- Polyamide 66/6
- V-O flammability
Color: Opaque White
10 mm
3.5 mm
3.6 mm
2.5-4mm224-10AWG
400V 300V
10A 20A
0.8Nm 7.2lb
Cat. No. Std. Pk.
HE42BU/02 100
HE42BU/03 100
HE42BU/04 100
HE42BU/05 100
HE42BU/06 50
HE42BU/07 50
HE42BU/08 50
HE42BU/09 50
HE42BU/10 50
HE42BU/11 50
HE42BU/12 50
HE42ST HE42BU
Pole Spacing
Mounting Hole Diameter
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Other Approvals
No. of Poles
2
3
4
5
6
7
8
9
10
11
12
A
N L
Eø E D C
R
M
I
K
ø
PQ
JO G F
B
H
Dimensions mm
A=10.0 J=15.2
B=M3 K= 7.9
C=6.4 L=117
D=3.6 M= 14.9
E=Ø3.5 N = 34.4
F=Ø5.7 O= 9.2
G = 10.0 P= 20
H=Ø3.5 Q= 14.4
I=3.2 R= 7
10 mm
3.5 mm
3.6 mm
2.5-4mm224-10AWG
400V 300V
10A 20A
0.8Nm 7.2lb
Cat. No. Std. Pk.
HE42ST/02 100
HE42ST/03 100
HE42ST/04 100
HE42ST/05 100
HE42ST/06 50
HE42ST/07 50
HE42ST/08 50
HE42ST/09 50
HE42ST/10 50
HE42ST/11 50
HE42ST/12 50
FLAT BASE
E211022 E211022
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com96
Eurostrips®
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 97
Dimensions mm
A=10.0 J=15.2
B=M3 K= 11.5
C=6.4 L=117
D=3.6 M= 18.5
E=Ø3.5 N = 34.4
F=Ø5.7 O= 9.2
G = 10.0 P= 20
H=Ø3.5 Q= 14.4
I=6.8 R= 7
10 mm
3.5 mm
3.6 mm
2.5-4mm224-10AWG
400V 600V
10A 20A
0.8Nm 7.2lb
Cat. No. Std. Pk.
HE42SBU/02 100
HE42SBU/03 100
HE42SBU/04 100
HE42SBU/05 100
HE42SBU/06 50
HE42SBU/07 50
HE42SBU/08 50
HE42SBU/09 50
HE42SBU/10 50
HE42SBU/11 50
HE42SBU/12 50
HE42SST HE42SBU
10 mm
3.5 mm
3.6 mm
2.5-4mm224-10AWG
400V 600V
10A 20A
0.8Nm 7.2lb
Cat. No. Std. Pk.
HE42SST/02 100
HE42SST/03 100
HE42SST/04 100
HE42SST/05 100
HE42SST/06 50
HE42SST/07 50
HE42SST/08 50
HE42SST/09 50
HE42SST/10 50
HE42SST/11 50
HE42SST/12 50
STANDOFF
FEET
E211022 E211022
A
N L
Eø E D C
R
M
I
K
ø
PQ
JO G F
B
H
Eurostrips®
Pole Spacing
Mounting Hole Diameter
Stripping Length
Approvals
Wire Range
Voltage Rating
Current Rating
Torque
Other Approvals
No. of Poles
2
3
4
5
6
7
8
9
10
11
12
Isolation Partition
Eurostrip
Thickness
Ordering Information
KA46
HE4HN, HE6H
3.4 mm (.134 in.)
Cat. No. Std. Pk.
HEP4/6H 5
EXTERNAL JUMPERS
Accessories
Convenient options that facilitate
installation and wire termination.
External Jumpers
Bus potentials between poles
on Eurostrip Terminal Strips
reducing wiring time and elim-
inating wire jumpers.
Jumper Pole positions may be
removed to provide selective
jumpering. When using exter-
nal jumpers, the terminal's
rated cross section is usually
reduced one wire size. For
jumper maximum current rat-
ings, refer to the correspon-
ding Eurostrip IEC/VDE current
rating.
Material: copper alloy,
nickel plated
Insulation: polyamide 6.6
Color: black.
Isolation Partitions
Isolation Partition KA provides
separation between adjacent
poles of different potentials on
600V Eurostrips with standoff
feet. Visual separation
between poles is also provid-
ed by an isolation partition,
assisting circuit identification
and increasing wiring efficien-
cy
Material: polyamide 6.6
Color: black
ISOLATION PARTITION
External Jumper
Eurostrip
Pole Spacing
Ordering Information
HCL8 HCL10 HCL12 HCL15
HE1 HE4 HE6 HE10, HE16
8mm (.315) 10 mm (.394 in.) 12 mm (.472) 15 mm (.591 in.)
Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk.
HCL8-2 100 HCL10-2 100 HCL12-2 100 HCL15-2 100
HCL8-3 100 HCL10-3 100 HCL12-3 100 HCL15-3 100
HCL8-4 100 HCL10-4 100 HCL12-4 100 HCL15-4 100
HCL8-12 25 HCL10-12 25 HCL12-12 25 HCL15-12 25
2 pole
3 pole
4 pole
12 pole
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com98
Eurostrips®
Altech Corp.® 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 99
HIL
W
Ø
Accessories
Convenient options that facilitate
installation and wire termination.
Mounting Pins
Speed panel mounting of
Eurostrips with Mounting
Pins. Simply match drill clear-
ance hole in panel, position
Eurostrip and install Mounting
Pin through hole and into
mounting hole in Eurostrip
housing. Once pin passes
beyond Eurostrip housing, it
automatically expands, secur-
ing housing to panel. Use two
or more mounting pins per
Eurostrip.
Material: polycarbonate
Color: gray.
Marking Plates
Install Marking Plate MP
under or on top of Eurostrip
housing to identify individual
pole positions to increase
wiring efficiency, save instal-
lation time and facilitate wire
hook-up, system modification
and trouble shooting. Select
blank marking plate for hand
marking or imprinted.
Material: self-extinguishing
PVC
Color: white with black
imprint.
Imprinting
Mark individual pole positions
to save installation time and
facilitate wire hook-up, sys-
tem modification and trouble
shooting. Choose turret mark-
ing for optimum identifica-
tion. To order imprinting spec-
ify consecutive, identical or
custom character imprints.
Imprints: rub-resistant,
black ink.
Set up fee applies
1000 piece minimum
Mounting Pins
Eurostrip
Panel Thickness
Ordering Information
H4 H6
HE4HN HE6H
0.5-1.5 mm 0.8-1.8 mm
Cat. No. Std. Pk. Cat. No. Std. Pk.
H4 50 H6 50
MARKING PLATES
Eurostrip HE4, HE4HN HE6, HE6H HE10, HE10H, HE16, HE16H
Ordering Information Cat. No. Desc. Std. Pk Cat. No. Desc. Std. Pk. Cat. No. Desc. Std. Pk.
BS24E Blank 25 BS60E Blank 25 BS1016E Blank 25
BS24EM1-12 No. 1-12 25 BS60EM1-12 No. 1-12 25 BS1016EM1-12 No. 1-12 25
BS24EM13-24 No. 13-24 25 BS60EM13-24 No. 13-24 25 BS1016EM13-24 No. 13-24 25
IMPRINTING
Imprint
Marking
Instruction
Ordering Example
Turret Location
Consecutive, imprint 1 through 12,
Turret Location
Cat. No. Std. Pk.
HE4WPR/12i1-12 1000
Turret Location
Dimensions mm (in.)
Mounting Pin Insertion Panel Width
Pin Type Height (H) Length (IL) Hole Dia. (W)
H4 21 12.6 4.2 8.5
H6 24 14.7 5.2 11
Eurostrips®
MOUNTING PINS