LC3-CP 10 LC3-CP 11 (4710) (4711) Photovoltaic chassis receptacle, with crimp contact, for front mounting LC3-CP 10: plug LC3-CP 11: socket 1. Temperature range 2. Materials Body/housing LC3-CP 10 LC3-CP 11 Contact pin/bush Contact protection (plugs only) Sleeve (sockets only) Hexagonal nut 3. Mechanical data -40 C/+85 C (+110 C upper limit temperature) TPU, V0 according to UL 94 halogen-free, UV-resistant CuZn, pre-nickeled and tinned PA 6.6, V0 according to UL 94 CuZn, nickeled PA 6.6 GF 60 N Insertion force1 65 N Withdrawal force1 Mating with photovoltaic connectors LC3 2 IP 68 Protection degree Connectable conductors crimp terminal Section LC3-CP 10-... 2.5 2.5 mm2 (AWG 14) Section LC3-CP 10-... 4.0 4.0 mm2 (AWG 12) Section LC3-CP 10-... 6.0 6.0 mm2 (AWG 10) 4. Electrical data (at Tamb 20 C) Contact resistance 5.0 m Rated current LC3-CP ... 2.5 22 A at Tamb 85 C Rated current LC3-CP ... 4.0 35 A at Tamb 85 C Rated current LC3-CP ... 6.0 40 A at Tamb 85 C 3 1000 V DC Rated voltage 3 III (8 kV) Overvoltage category I (CTI 600) Material group3 Creepage distance 12.5 mm Clearance 12.5 mm Insulation resistance > 10 G 1 measured with a proper counterpart 2 1 m/24 h, only in mated condition with a proper counterpart IP X8 requirements under agreement between manufacturer and user 3 according to DIN EN 60664/IEC 60664 (R) (R) under preparation *a recess for optional unmating preventer LC3-CX 90 according to NEC 2008 NFPA 70 *b marking + on LC3-CP ...-1, - bei LC3-CP ...-2 *c nut enclosed separately 32 Composition of type designation Features and benefits Series: LC3 or LC4 Type of product CP Connector Part Configuration 10 chassis plug 11 chassis socket Polarity -1 + -2 - Cable section 2.5 2.5 mm 4.0 4.0 mm 6.0 6.0 mm * chassis receptacles for system components such as inverters, generator isolation housings or accumulation boxes * quick and easy assembly * manual tool and crimping machine allow for costeffective assembly of small and high volumes * rugged and durable for permanently reliable system operation * optional locking according to NEC 2008 NFPA 70 * with contact-voltage protection * highest protection degree IP 68 * UV and ozone-resistant * halogen-free * protective caps available for transport or spare receptacles LC3-CP 10-1 4.0 Typical examples Designation Description Polarity Section (mm2) LC3-CP 10-1 4.0 chassis plug + 4.0 LC3-CP 10-1 6.0 chassis plug + 6.0 LC3-CP 11-2 4.0 chassis socket - 4.0 LC3-CP 11-2 6.0 chassis socket - 6.0 Package unit: 100 pieces in a cardboard box 33 LC3(R) Wiring solutions for photovoltaic power systems LC3(R)-CP - Connector Parts without cable