Current Probes
Accurately Measure
AC, DC and Impulse
Currents
2
Measure Currents in a Wide Range of Applications
Measuring AC and
DC Currents
LeCroy current probes do not
require the breaking of a circuit
or the insertion of a shunt to
make accurate and reliable current
measurements. Based on a combi-
nation of Hall effect and transformer
technology, LeCroy current probes
are ideal for making accurate AC, DC,
and impulse current measurements.
Fully Integrated with
Oscilloscope
Many current probes require external
power supplies or amplifiers to display
a waveform on the oscilloscope
screen. All LeCroy current probes
are powered through the LeCroy
ProBus®connection and require
no additional hardware. Along
with providing power, the ProBus
connection allows the current probe
and oscilloscope to communicate,
resulting in current waveforms
automatically displayed on screen
in Amps, and calculated power traces
scaled correctly in Watts. This full
integration also allows for Degauss
and Autozero functions to be done
directly from the oscilloscope with
a single button press.
Applications
LeCroy current probes are available
in a wide range of models for a
wide range of applications. The
full range of LeCroy current probes
includes models with bandwidths
up to 100 MHz, peak currents up to
700 A and sensitivities to 10 mA/div.
Multiple current probes can be used
together to make measurements
on three-phase systems, or a single
current probe can be used with a
voltage probe to make accurate
instantaneous power measurements.
LeCroy current probes are often used
in applications such as the design and
test of switching power supplies,
motor drives, electric vehicles, and
uninterruptible power supplies.
3
CP031 30A, 100 MHz Current Probe
Features
100 MHz bandwidth
Small form factor
accommodates large
conductors with small
jaw size
30 Arms continuous
current, 50 A peak current
Electrical Characteristics*
Max. Continuous Input Current 30 A
Bandwidth 100 MHz
Max. Peak Current at Pulse Width 50 A < 10 µs
Rise Time (typical) < 3.5 ns
Minimum Sensitivity 20 mA/div
Low Frequency Accuracy 1%
AC Noise < 2.5 mA
Coupling AC, DC, GND
* Guaranteed at 23 °C ±3 °C
General Characteristics
Cable Length 1.5 m
Weight 240 g
Max. Conductor Size (diameter) 5 mm
Interface ProBus, 1 Monly
Usage Environment Indoors
Operating Temperature 0 °C to 40 °C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated Wire Voltage 300 V CAT I
Requires AP-1M for use with 50 input only oscilloscopes.
0
5
10
15
20
25
30
35
Frequency (Hz)
Current
(Arms)
Maximum Input Current vs. Frequency
0.001
0.01
0.1
1
10
Frequency (Hz)
Insertion
Impedance
()
Insertion Impedance vs. Frequency
(typical)
The CP031 is compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater.
The CP031 is LeCroy’s highest bandwidth current probe. Along with the high 100 MHz bandwidth the CP031can probe
continuous currents of 30 Arms and peak currents up to 50 A. The CP031 features a small form factor making it easier
to probe on a crowded, compact board.
4
CP030 30 A, 50 MHz Current Probe
Features
Small form factor
accommodates large
conductors with small
jaw size
30 Arms continuous
current, 50 MHz bandwidth
50 A peak current
Electrical Characteristics*
Max. Continuous Input Current 30 A
Bandwidth 50 MHz
Max. Peak Current at Pulse Width 50 A < 10 µs
Rise time (typical) < 7 ns
Minimum Sensitivity 20 mA/div
Low Frequency Accuracy 1%
AC Noise < 2.5 mA
Coupling AC, DC, GND
* Guaranteed at 23 °C ±3 °C
The CP030 was designed with a small form factor for today’s crowded boards. The small jaw can probe currents in tight
spaces and still clamp onto conductors up to 5 mm in diameter. Continuous currents of 30 Arms and peak currents
of 50 A can be measured by the CP030, which also features a 50 MHz bandwidth.
General Characteristics
Cable Length 1.5 m
Weight 240 g
Max. Conductor Size (diameter) 5 mm
Interface ProBus, 1 Monly
Usage Environment Indoors
Operating Temperature 0 °C to 40 °C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated Wire Voltage 300 V CAT I
Requires AP-1M for use with 50 input only oscilloscopes.
The CP030 is compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater.
0
5
10
15
20
25
30
35
Frequency (Hz)
Current
(Arms)
Maximum Input Current vs. Frequency
Frequency (Hz)
0.001
0.01
0.1
1
10
Insertion Impedance vs. Frequency
(typical)
5
AP015 30 A, 50 MHz Current Probe
Electrical Characteristics
Max. Continuous Input Current 30 A
Bandwidth 50 MHz
Max. Peak Current at Pulse Width 50 A < 10 s
Rise time (typical) < 7 ns
Minimum Sensitivity 10 mA/div
Low Frequency Accuracy 1%
Coupling AC, DC, GND
The AP015 current probe can measure continuous current of 30 Arms and peak pulses of up to 50 A for durations up to
10 seconds. This probe also features an overheating protection circuit, which will display an on-screen warning to the user
to prevent damage. A probe unlock detection feature is also built in to the AP015 to ensure accurate measurements.
General Characteristics
Cable Length 2 m
Weight 300 g
Max. Conductor Size (diameter) 5 mm
Interface ProBus, 1 Monly
Usage Environment Indoors
Operating Temperature 0 °C to 40 °C
Max. Relative Humidity 80% (Max. 31 °C)
Max. Altitude 2000 m
Maximum Insulated Wire Voltage 300 V CAT I, 150 V CAT II
Requires AP-1M for use with 50 input only oscilloscopes.
Features
30 Arms continuous
current, 50 MHz bandwidth
50 A peak current for
up to 10 seconds
Overheating and Probe
Unlock Detection
0.001
0.01
0.1
1
10
Frequency (Hz)
Insertion
Impedance
()
Insertion Impedance vs. Frequency
(typical)
CP500 Features
500 Arms
continuous current
700 A peak
2 MHz bandwidth
6
6
CP150 150 A, 10 MHz Current Probe
CP500 500 A, 2 MHz Current Probe
CP150 Features
150 Arms continuous
current
500 A peak
10 MHz bandwidth
Electrical Characteristics
Max. Continuous 150 A
Input Current
Bandwidth 10 MHz
Max. Peak Current 500 A < 30 µs
at Pulse Width
Rise time (typical) < 35 ns
Minimum Sensitivity 200 mA/div
Max. In-Phase Current 500 A
Low Frequency Accuracy 1%
AC Noise 25 mA
Coupling AC, DC, GND
General Characteristics
Cable Length 2 m
Weight (probe only) 500 g
Max. Conductor 20 mm
Size (diameter) ProBus, 1 Monly
Interface
Usage Environment Indoors
Operating Temperature 0 °C to 40 °C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated 600 V CAT II,
Wire Voltage 300 V CAT III
Requires AP-1M for use with 50 input
only oscilloscopes.
20
0
40
60
80
100
120
140
160
Frequency (Hz)
Current
(A rms)
Maximum Input Current vs. Frequency
0.001
0.01
0.1
1
Frequency (Hz)
Insertion
Impedance
Insertion Impedance vs. Frequency
(typical)
0
50
100
150
200
250
300
350
400
450
500
550
Frequency (Hz)
Current
(A rms)
10 100 1 k 10 k 100 k 1 M 10 M
Maximum Input Current vs. Frequency
0.001
0.010
0.100
Frequency (Hz)
Insertion
Impedance
Insertion Impedance vs. Frequency
(typical)
Electrical Characteristics
Max. Continuous 500 A
Input Current
Bandwidth 2 MHz
Max. Peak Current 700 A
at Pulse Width
Rise time (typical) < 175 ns
Minimum Sensitivity 200 mA/div
Max. In-Phase Current 1150 A
Low Frequency Accuracy 1%
AC Noise 25 mA
Coupling AC, DC, GND
General Characteristics
Cable Length 6 m
Weight (probe only) 630 g
Max. Conductor 20 mm
Size (diameter) ProBus, 1 Monly
Interface
Usage Environment Indoors
Operating Temperature 0 °C to 40 °C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated 600 V CAT II,
Wire Voltage 300 V CAT III
Requires AP-1M for use with 50 input
only oscilloscopes.
DCCP
07/05
Local sales offices are located throughout the world.
To find the most convenient one visit www.lecroy.com
© 2005 by LeCroy Corporation. All rights reserved. Specifications subject to change without notice.
Other product or brand names are trademarks or requested trademarks of their respective holders.
Ordering Information
Description Product Code
30 A; 100 MHz Current Probe AC/DC; 30 Arms; 50 A Peak Pulse CP031
30 A; 50 MHz Current Probe AC/DC; 30 Arms; 50 A Peak Pulse CP030
30 A; 50 MHz Current Probe AC/DC; 30 Arms; 50 A Peak Pulse AP015
150 A; 10 MHz Current Probe AC/DC; 150 Arms; 500 A Peak Pulse CP150
500 A; 2 MHz Current Probe AC/DC; 500 Arms; 700 A Peak Pulse CP500
Customer Service
LeCroy oscilloscopes are designed, built, and tested to ensure high reliability.
In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years.
This warranty includes: No charge for return shipping Long term 7-year support Upgrade to latest software at no charge
Related Products and Ordering Information
DA1855A Differential Amplifier
The DA1855A high-performance
differential amplifier provides
100 MHz bandwidth, industry
leading overdrive recovery, and
outstanding common mode rejection ratio. The fast overdrive
recovery provides the ability to make critical saturation voltage
measurements while the high CMRR enables upper gate drive
measurements. Built into the DA1855A is a precision voltage
generator for offset far greater than the oscilloscope can provide
on its own. The DA1855A can be operated in true differential
mode or switched to comparator mode.
DCS015 Deskew Calibration Source
To make accurate instantaneous power
measurements it is critical that both
the current and voltage waveforms be
aligned in time. The DCS015 calibration
source has both voltage and current time-aligned signals, which
enables the precise deskew of voltage and current probes. Most
voltage probes along with the AP015, CP015, CP030, and CP031
are compatible with the DCS015.
ADP300 and ADP305
Active Differential Probes
The ADP300 and ADP305 are high-voltage
differential probes ideal for measuring
power electronics. The 20 MHz bandwidth
ADP300 is good for troubleshooting low
frequency power devices and other circuits
where the reference potential is elevated
from the ground or the ground is unknown. The 100 MHz
bandwidth ADP305 is designed for measuring the floating
voltages found in today’s high-speed power electronics.
PMA2 Power Measurement
Analysis Software
The PMA2 software option is used to
make critical power switching device
measurements, perform control loop
modulation analysis, and measure
power harmonics. With PMA2, the
display and setup of voltage waveforms, current waveforms,
and necessary measurement parameters are done automatically.
Important device measurements like power losses, saturation
voltage dynamic-on resistance, and safe operating area are easily
performed. Pre-compliance testing to EN 61000-3-2 with easy-to
-read graphical and tabular pass/fail results is built in to PMA2.
Related Products
1-800-5-LeCroy
www.lecroy.com