TABLE 2
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in) mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
TABLE 3
Termination Options:-
SELECT DESCRIPTION
OPTION
A or F
B Crimped terminals
C 6.35mm fastons
D AMP MTE 2.54mm pitch
E JST XHP 2.5mm pitch
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
CUSTOMER OPTIONS - Cable Length and Termination Specification
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURA TE FOR ANY P AR TICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request,HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
59036
Switch Type Table 1
Table 2
Table 3
Sensitivity
Cable Length
Termination
www.hamlin.com
X T XX X
Hamlin USA Tel: +1 920 648 3000 Fax:+1 920 648 3001 Email: sales.us@hamlin.com
Hamlin UK Tel: +44 (0)1379 649700 Fax:+44 (0)1379 649702 Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660 Fax:+49 (0) 6181 9536666 Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 Fax:+33 (0) 1 4686 6786 Email: sales.fr@hamlin.com
TABLE 2
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in) mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
TABLE 3
Termination Options:-
SELECT DESCRIPTION
OPTION (2 WIRE VERSIONS ILLUSTRATED)
A Tinned or untinned leads
B Crimped terminals
C 6.35mm fastons
D AMP MTE 2.54mm pitch
E JST XHP 2.5mm pitch
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
CUSTOMER OPTIONS - Cable Length and Termination Specification
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURA TE FOR ANY P AR TICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request,HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
www.hamlin.com
59630 Float Sensor Features and Benefits
TABLE 1 Form A Normally Normally Open Change Normally
Contact Type Open High Voltage Over Closed
Switch T ype 12 34
Power Watt - max. 10 10 5 10
Voltage Switching Vdc - max. 200 300 175 200
Breakdown Vdc - min. 250 450 200 250
Current Switching A - max. 0.5 0.5 0.25 0.5
Carry A - max. 1.2 1.5 1.5 1.2
Resistance Contact,Initial - max. 0.2 0.2 0.2 0.2
Insulation - min. 1010 1010 1091010
Capacitance Contact pF - typ. 0.3 0.2 0.3 0.3
Temperature Operating °C -40 to +105-20 to +105-40 to +105-40 to +105
Storage °C -50 to +105-50 to +105-50 to +105-50 to +105
Time Operate ms - max. 1.0 1.0 3.0 1.0
Release ms - max. 1.0 1.0 3.0 1.0
Shock 11ms 1⁄2 sine G - max. 100 100 50 100
Vibration 50-2000 Hz G - max. 30 30 30 30
TABLE 2
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in) mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
ACTIVATION
Using sensor with float magnet orientated as
illustrated below
59630
Series 59630
Features
Sensor with integral float magnet
attached
Sensor operates when float rises
from end stop position
Choice of contacts
Choice of connector
Customer defined cable length
Benefits
No standby power required
Hermetically sealed,magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Simple installation with M8 thread
and nut
Applications
Liquid level control
Air conditioning systems
Industrial Process Control
ISSUE No:4 DATE: 1/5/3