© PHOENIX CONTACT 2013-04-08
105504_en_01
ME PLC 40...
Data sheet
1 Description
The housings of the ME PLC 40... product group consist of
a 40-mm wide housing base with much space for the PCB
assembly.
The housing base can be combined with various covers.
There are connection technology carriers on which the PCB
plug-in connectors (FKCN 2.5...) are already premounted.
These plug-in connectors have a push-in connection for
conductor cross sections up to 2.5 mm².
In addition, a connection technology carrier with RJ45-plug-
in connectors and a universal cover are available. The uni-
versal cover is especially suited for installing connection
systems or display and operating elements. We would be
glad to install the required openings for you.
The housings can be snapped onto an NS 105/20 DIN rail.
They can be combined with a DIN rail connector. The bus
connectors supplied unmounted and can be equipped with
PCBs as needed.
Bus connectors are available with the number of positions
50/40 and 10/10, i.e. 50-pos. in the DIN rail / 40-pos. into the
device or otherwise 10-pos. in the DIN rail / 10-pos. into the
device.
If you do not need a bus connector, you can also fasten the
housing onto two NS 35 DIN rails.
The 3D housing data can be found at phoenixcontact.net/products.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.net/products.
This data sheet is valid for all products listed on the following page:
Multifunctional housing for complex electronics
ME PLC 40...
105504_en_01 PHOENIX CONTACT 2
Table of contents
1 Description.................................................................................................................................. 1
2 Ordering data.............................................................................................................................. 3
3 Overview of the ME PLC Products.............................................................................................. 4
4 Lower part of the housing............................................................................................................ 5
4.1 Outer dimensions of the housing base ...........................................................................................................5
4.2 Inner dimensions of the housing base ............................................................................................................5
5 Connection technology carrier...........................................................................................................................6
5.1 Connection of the conductors to the PCB plug-in connector (push-in connection).........................................6
5.2 Place the connection technology carrier on the housing base........................................................................6
5.3 Connection technology carrier CT10 ..............................................................................................................7
5.4 Connection technology carrier CT20 ..............................................................................................................9
5.5 Connection technology carrier CT36 ............................................................................................................11
5.6 Connection technology carrier RJ45 ............................................................................................................13
5.7 Universal cover CL .......................................................................................................................................14
6 Bus connector set..................................................................................................................... 15
6.1 Bus connector 50/40 ....................................................................................................................................15
6.2 Bus connector 10/10 ....................................................................................................................................21
7 Array and fitted plate................................................................................................................. 27
7.1 Dimensional drawing array ...........................................................................................................................27
7.2 Dimensional drawing fitted plate...................................................................................................................27
7.3 Dimensional drawing of the PCB for mounting under array or fitted plate.....................................................28
7.4 Dimensional drawing housing PCB (housing with array or with fitted plate)..................................................28
8 Close with cover (without array or fitted plate) .......................................................................... 29
8.1 Dimensional drawing housing PCB ..............................................................................................................29
9 Mounting on a DIN rail .............................................................................................................. 30
9.1 Mounting on NS 105/20................................................................................................................................30
9.2 Mounting on NS 35/15..................................................................................................................................30
ME PLC 40...
105504_en_01 PHOENIX CONTACT 3
2 Ordering data
Housing
DESCRIPTION Type Order no. Pcs. / pack
Housing base, suitable for 50/40 bus connector, color: light gray ME PLC 40 B BUS 50/40 GY7035 2201500 10
Housing base, suitable for 10/10 bus connector, color: light gray ME PLC 40 B BUS 10/10 GY7035 2201499 10
Universal cover, long design, color: light gray ME PLC 40 CL GY7035 2201505 10
Connection technology carrier, fully assembled with FKCN 2 x 10-pos.,
cover and release lever, incl. fitted cover
Matching PCB plug-in connector: 1 x CCDN 2.5/10-G1 P26 THR (1734355)
ME PLC 40 CT20 GY7035 2201493 10
Connection technology carrier, fully assembled with FKCN 2 x 18-pos.,
cover and release lever, incl. fitted cover
Matching PCB plug-in connector: 1 x CCDN 2.5/18-G1 P26 THR (1734436)
ME PLC 40 CT36 GY7035 2201494 10
Connection technology carrier, fully assembled with FKCN 1 x 10-pos.,
cover and release lever, incl. fitted cover
Matching PCB plug-in connector: MSTBA 2.5/10-G (1757543)
ME PLC 40 CT10 GY7035 2201492 10
Connection technology carrier for RJ45 connection, pre-assembled with
cover and release lever; incl. fitted cover and 2 x RJ45 connector plugs
ME PLC 40 CTRJ45 GY7035 2201495 10
Accessories
DESCRIPTION Type Order no. Pcs. / pack
Cover, short design, color: light gray ME PLC 40 CS GY7035 2201490 10
Cover, short design, color: transparent ME PLC 40 CS TRANS 2201491 10
Fitted plate, for assembly underneath the cover in short design
(ME PLC 40 CS...), color: light gray
ME PLC 40 PL S GY7035 2201497 10
Matrix with defined engagement mechanism, for assembly underneath the
cover in short design (ME PLC 40 CS...), color: black
ME PLC 40 MT S BK 2201496 10
Bus connector kit consisting of 50-pos. and 40-pos. plug-in connectors,
plastic upper part and base, plus metal clamps for mounting the DIN rail, PCB
not included
ME PLC 40 BUS 50/40 KIT BK 2201502 10
Bus connector kit consisting of 2 x 10-pos. plug-in connectors, plastic upper
part and base, plus metal clamp for mounting the DIN rail, PCB not included
ME PLC 40 BUS 10/10 KIT BK 2201503 10
End brackets for DIN rail mounting, incl. mounting screws ME PLC EBT GY7035 2201498 10
DIN rail, unperforated, 105 x 20 mm, galvanized and thick layer passivated,
cut to customer-specific length (between 40 mm and 2000 mm)
Specify length in [mm] according to order key: quantity / order no. / length (e.g.
for 1 x 40 mm long: 1 / 2201508 / 40)
NS 105/20 UNPERF 2201508 1
Coding set, for coding housing base and bus connector
Drop, color: red
Rectangle, color: red
Drop, color: green
Rectangle, color: green
COD PI 4 RD
COD PI 2 RD
COD PI 1 GN
COD PI 3 GN
2201618
2901877
2901864
2201617
100
100
100
100
ME PLC 40...
105504_en_01 PHOENIX CONTACT 4
3 Overview of the ME PLC Products
Figure 1 Overview
ME PLC 40 CS TRANS
ME PLC 40 MT S BK
ME PLC 40 CL
ME PLC 40 CS GY7035
ME PLC 40 PL S GY7035
ME PLC 40 CT10
ME PLC 40 CTRJ45
ME PLC 40 CT36
ME PLC 40 CT20
ME PLC 40 B BUS 50/40
ME PLC 40 B BUS 10/10
ME PLC EBT
ME PLC 40 BUS 10/10 KIT
ME PLC 40 BUS 50/40 KIT
NS 105/20
ME PLC 40...
105504_en_01 PHOENIX CONTACT 5
4 Lower part of the housing
4.1 Outer dimensions of the housing base
Figure 2 Housing base, side view
Figure 3 Housing base, front view
4.2 Inner dimensions of the housing base
Figure 4 Housing base, internal view
Figure 5 Maximum dimensions of the PCB of the hous-
ing
Housing base, suitable for 50/40 bus connector, color: light
gray
ME PLC 40 B BUS 50/40 GY7035 2201500
Housing base, suitable for 10/10 bus connector, color: light
gray
ME PLC 40 B BUS 10/10 GY7035 2201499
180
145
159
139
20
40
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
22
27,91,5
5,6
166,8
37
134
94
ME PLC 40...
105504_en_01 PHOENIX CONTACT 6
5 Connection technology carrier
5.1 Connection of the conductors to the PCB plug-
in connector (push-in connection)
Figure 6 Push-in connection
1.5 mm² conductor cross section ... 2.5 mm², rigid or
with ferrule
Insert the stripped wire into the round opening of the ter-
minal block without using a tool.
Wires with a smaller cross section or stranded con-
ductors without ferrule
To release the spring, push in the orange pushbutton
with a screwdriver.
Dismantling
For release, push in the orange pushbutton with a
screwdriver.
5.2 Place the connection technology carrier on the
housing base
Swivel the red lever to the right.
Hook in the two engagement noses of the connection
technology carrier into the openings of the housing
base.
.
Figure 7 Snap in
Figure 8 Close
Swivel the lever back to the left.
The connection technology carrier slides into the hous-
ing.
If that does not go easily, check the seating of the en-
gagement noses.
A
B
ME PLC 40...
105504_en_01 PHOENIX CONTACT 7
5.3 Connection technology carrier CT10
5.3.1 Dimensional drawing PCB fragment and drilling diagram CT10
Figure 9 Dimensional drawing of the PCB of the housing when using the connection technology carrier CT10
Connection technology carrier, fully assembled with FKCN
1 x 10-pos., cover and release lever, incl. fitted cover
ME PLC 40 CT10 GY7035 2201492
Matching PCB plug-in connector MSTBA 2.5/10-G 1757543
45
53,5
26,7 5 5 5 5 5 5 5 5
Ø 1,4
3,45
10
166,8
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
ME PLC 40...
105504_en_01 PHOENIX CONTACT 8
5.3.2 PCB plug-in connector for CT10
To connect the connection technology carrier
ME PLC 40 CT10 to the PLC, you need the PCB plug-in
connector MSTBA 2.5/10-G.
Figure 10 Dimensions MSTBA 2.5/10-G
MSTBA 2.5/10-G, 1757543
153,5
12
22
8,6
23,5 5
a
a+7
a = 45 mm
Dimensions / Positions
Length 12 mm
Pitch 5 mm
Dimension a 45 mm
No. of positions 10
Pin dimensions 1 x 1 mm
Hole diameter 1.4 mm
Technical data
Range of articles MSTBA 2.5/…-
G-…
Insulation material group IIIa
Rated surge voltage (III/3) 4 kV
Rated surge voltage (III/2) 4 kV
Rated surge voltage (II/2) 4 kV
Rated voltage (III/2) 320 V
Rated voltage (II/2) 400 V
Connection in acc. with standard EN-VDE
Nominal current IN 12 A
Nominal voltage UN250 V
Maximum load current 12 A
Insulation material PBT
Inflammability class in acc. with UL 94 V0
Color green
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 15 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 15 A
ME PLC 40...
105504_en_01 PHOENIX CONTACT 9
5.4 Connection technology carrier CT20
5.4.1 Dimensional drawing PCB fragment and drilling diagram CT20
Figure 11 Dimensional drawing of the PCB of the housing when using the connection technology carrier CT20
Connection technology carrier, fully assembled with FKCN
2 x 10-pos., cover and release lever, incl. fitted cover
ME PLC 40 CT20 GY7035 2201493
Matching PCB plug-in connector CCDN 2.5/10-G1 P26 THR 1734355
45
53,9
26,7 5 5 5 5 5 5 5 5
Ø 1,6
3,45
5
10
166,8
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
ME PLC 40...
105504_en_01 PHOENIX CONTACT 10
5.4.2 PCB plug-in connector for CT20
To connect the connection technology carrier
ME PLC 40 CT20 with the PLC, you need the PCB plug-in
connector CCDN 2.5/10-G1 P26 THR.
Figure 12 Dimensions CCDN 2.5/10-G1 P26 THR
CCDN 2.5/10-G1 P26 THR, 1734355
2,6 20,1
17,6
10 53,9 5
a
a+7,8
a = 45 mm
Dimensions / Positions
Length 17.6 mm
Pitch 5 mm
Dimension a 45 mm
No. of positions 10
Pin dimensions 1 x 1
Hole diameter 1.6 mm
Technical data
Range of articles CCDN 2.5/..-
G1-THR
Insulation material group IIIa
Rated surge voltage (III/3) 4 kV
Rated surge voltage (III/2) 4 kV
Rated surge voltage (II/2) 4 kV
Rated voltage (III/2) 400 V
Rated voltage (II/2) 400 V
Connection in acc. with standard EN-VDE
Nominal current IN 12 A
Nominal voltage UN 320 V
Maximum load current 12 A
Insulation material LCP
Inflammability class in acc. with UL 94 V0
Color black
ME PLC 40...
105504_en_01 PHOENIX CONTACT 11
5.5 Connection technology carrier CT36
5.5.1 Dimensional drawing PCB fragment and drilling diagram CT36
Figure 13 Dimensional drawing of the PCB of the housing when using the connection technology carrier CT36
Connection technology carrier, fully assembled with FKCN
2 x 18-pos., cover and release lever, incl. fitted cover
ME PLC 40 CT36 GY7035 2201494
Matching PCB plug-in connector CCDN 2.5/18-G1 P26 THR 1734436
85
53,9
26,7 5 5 5 5 5 5 5 5
Ø 1,6
3,45
5
10
5 5 5 5 5 5 5 5
166,8
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
ME PLC 40...
105504_en_01 PHOENIX CONTACT 12
5.5.2 PCB plug-in connector for CT36
To connect the connection technology carrier
ME PLC 40 CT36 to the PLC, you need the PCB plug-in
connector CCDN 2.5/18-G1 P26 THR.
Figure 14 Dimensions CCDN 2.5/18-G1 P26 THR
CCDN 2.5/18-G1 P26 THR, 1734436
2,6 20,1
17,6
10 53,9 5
a
a+7,8
a = 85 mm
Dimensions / Positions
Length 17.6 mm
Pitch 5 mm
Dimension a 85 mm
No. of positions 18
Pin dimensions 1 x 1
Hole diameter 1.6 mm
Technical data
Insulation material group IIIa
Rated surge voltage (III/3) 4 kV
Rated surge voltage (III/2) 4 kV
Rated surge voltage (II/2) 4 kV
Rated voltage (III/2) 400 V
Rated voltage (II/2) 400 V
Connection in acc. with standard EN-VDE
Nominal current IN 12 A
Nominal voltage UN 320 V
Maximum load current 12 A
Insulation material LCP
Inflammability class in acc. with UL 94 V0
Color black
ME PLC 40...
105504_en_01 PHOENIX CONTACT 13
5.6 Connection technology carrier RJ45
5.6.1 Dimensional drawing PCB fragment and drilling diagram RJ45
Figure 15 Dimensional drawing of the PCB housing when using the connection technology carrier RJ45
Connection technology carrier for RJ45 connection, pre-
assembled with cover and release lever; incl. fitted cover and
2 x RJ45 connector plugs
ME PLC 40 CTRJ45 GY7035 2201495
Ø3,2
Ø1,6
11,94
1,8
5,2
8,1 2,5
1,5
6,7
8,4 13
4,2
4,2
2,04
2,04
6
6
11,1
15,75 6,4
3,7
5,7
16,3
15,3
Ø0,9
45°
45°
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
Technical data
Connector type RJ45
Contact type Socket
Number of contacts 8
Number of locations 8
Number of ports 1
LAN type CAT6A
Contact connection Push-through
assembly, per-
pendicular
ME PLC 40...
105504_en_01 PHOENIX CONTACT 14
5.7 Universal cover CL
5.7.1 Dimensional drawing PCB CL
Figure 16 Dimensional drawing of the PCB of the housing when using the universal cover CL
Figure 17 Maximum useable area for break-outs (A)
The middle lines in Figure 16 and Figure 17 refer to the loca-
tion in the housing base.
Universal cover, long design, color: light gray ME PLC 40 CL GY7035 2201505
1044 3
1
1
2
5,5
17,6
17,6
5,5
2
R1,2
R1,2
R1,2
R1,2
We can gladly make openings for any of your dis-
play or operating elements.
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
105 14
28
A
ME PLC 40...
105504_en_01 PHOENIX CONTACT 15
6 Bus connector set
6.1 Bus connector 50/40
6.1.1 Overview of the set 50/40
Figure 18 Overview set 50/40
6.1.2 Mounting
Solder the plug-in connectors A1, A2, and B1 onto your
PCB.
Solder the two metal terminals onto your PCB.
Insert the PCB.
Put the top and bottom parts together.
Solder the plug-in connector B2 to the PCB of the hous-
ing base ME PLC 40 B BUS 50/40 GY7035, 2201499.
6.1.3 Coding
You have the option to codify the bus connector and the
housing. This should prevent a housing being accidentally
plugged onto the wrong bus connector.
Figure 19 Coding option
Coding sets in rectangular and drop form are available (see
“Ordering data” on page 3).
Plug one part of the coding set into the opening of the
bus connector.
The counter-part goes into the housing.
Bus connector kit consisting of 50-pos. and 40-pos. plug-in
connectors, plastic upper part and base, plus metal clamps for
mounting the DIN rail, PCB not included
ME PLC 40 BUS 50/40 KIT BK 2201502
A1
A2
B2
B1
Observe the proper orientation of the PCB when
inserting it into the housing. The housing base
has raised supports on one side. The PCB side
with the cut-out belongs on this side.
ME PLC 40...
105504_en_01 PHOENIX CONTACT 16
6.1.4 Dimensional drawing PCB 50/40
Figure 20 Dimensional drawing of the PCB for the bus connector set 50/40
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
27,7
8,7
27,7
19,6 2,4
86
41,9
39,6
21,7
15,6 10,1
R1,2
1,5
Ø1,35
10
2,5
2,5
2,55
1,5
2,2
3,1
ME PLC 40...
105504_en_01 PHOENIX CONTACT 17
6.1.5 50-pos. plug-in connector (A1) for 50/40
Figure 21 Dimensions A1, 50-pos
Figure 22 Drilling diagram A1, 50-pos.
A1
The precise location of the plug-in connectors on
the PCB can be found in Figure 20 on page 16.
1,27
41,70
30,485,61
37,88
10,44
12,34
3,81
3,2
3,81
6,58
17,45
7,65
36,02
Ø2,6
5,61
30,48
6,88
1,9
27,94
37,9
2,54
Ø1
2,54
3,81
3,12
1,22
6,93
3,81
1
Dimensions / Positions
Pitch 1.27 mm
Width 41.70mm
No. of positions 50
Number of rows 4
Orientation Perpendicular
Hole diameter 1.0
Length of the solder pin 2.80 mm
Recommended thickness of the PCB 1.60 mm
Technical data
Current per connection 1 A, maximum
Voltage 30 V
Inflammability class in acc. with UL 94 V0
Color black
Temperature range, operating -55°C ...+105°C
Solder connection
Type of contact Soldering
method
Lead-free SMC & Wave
capable
(TH only)
Duration at maximum processing tem-
perature
5 s
Cycles at maximum processing temper-
ature
1, maximum
Processing temperature maximum
270°C
ME PLC 40...
105504_en_01 PHOENIX CONTACT 18
6.1.6 50-pos. plug-in connector (A2) for 50/40
Figure 23 Dimensions A2, 50-pos.
Figure 24 Drilling diagram A2, 50-pos.
A2
The precise location of the plug-in connectors on
the PCB can be found in Figure 20 on page 16.
5,61 30,48
1,27
36,02
37,88
41,70
10,44
12,34
3,81
3,28
3,81
6,58
17,45
7,65
37,88
27,94
6,88 2,54
5,61
30,48
2,54
Ø0,8 Ø2,6
10,44
1,3
3,81
3,2
3,81
1,91
1
Dimensions / Positions
Pitch 1.27 mm
No. of positions 50
Number of rows 4
Orientation Perpendicular
Hole diameter 0.8 mm
Length of the solder pin 2.79 mm
Recommended thickness of the PCB 1.60 mm
Technical data
Current per connection 1 A, maximum
Voltage 30 V
Inflammability class in acc. with UL 94 V0
Color black
Temperature range, operating -40°C ...+105°C
Solder connection
Type of contact Soldering
method
Lead-free SMC & Wave
capable
(TH only)
Duration at maximum processing tem-
perature
5 s
Cycles at maximum processing temper-
ature
1, maximum
Processing temperature maximum
270°C
ME PLC 40...
105504_en_01 PHOENIX CONTACT 19
6.1.7 40-pos. plug-in connector (B1) for 50/40
Figure 25 Dmensions B1, 40-pos.
Figure 26 Drilling diagram, 40-pos.
B1
The precise location of the plug-in connectors on
the PCB can be found in Figure 20 on page 16.
32,47
1,27
24,136,31
34,11
36,75
7,1
2,54
3,8
3,8 0,7
0,7
10
7,58
22,86
2,54
Ø1
Ø2,6
0,7
3,81
2,54
22,86
1,32 2,7
2,2
3,55
6,31
34,11
0,7 3,81
1
Dimensions / Positions
Pitch 1.27 mm
No. of positions 40
Number of rows 4
Orientation Vertical
Hole diameter 1.0 mm
Length of the solder pin 2.54 mm
Recommended thickness of the PCB 1.60 mm
Technical data
Current per connection 1 A, maximum
Voltage 250 V AC
Insulation material LCP
Inflammability class in acc. with UL 94 V0
Color black
Solder connection
Lead-free soldering process Yes
ME PLC 40...
105504_en_01 PHOENIX CONTACT 20
6.1.8 40-pos. plug-in connector (B2) for contacting in the bus connector set 50/40
Figure 27 Dimensions B2, 40-pos.
Figure 28 Drilling diagram B2, 40-pos.
B2
Figure 29 Dimensional drawing of the PCB of the housing (2201500) with plug-in connector (B2)
1,27
24,135,6
17,46
10,17
12,07
3,81
3,81
6,16
3,1 7,65
35,33
31,53
29,67
22,86
22,86
6,87
2,54
5,6
1,9
2,54
Ø1
Ø2,6
31,53
3,21
3,81
1,31
3,81
7,02
1
Dimensions / Positions
Pitch 1.27 mm
No. of positions 40
Number of rows 4
Orientation Perpendicular
Hole diameter 1.0 mm
Length of the solder pin 3.10 mm
Recommended thickness of the PCB 1.60 mm
Technical data
Current per connection 1 A, maximum
Voltage 250 V AC
Insulation material LCP
Inflammability class in acc. with UL 94 V0
Color black
Solder connection
Lead-free soldering process Yes
166,8
31,7
36,51
79,4 8
R1,2
R1,2
9,6
1,45
3,4
35,5
ME PLC 40...
105504_en_01 PHOENIX CONTACT 21
6.2 Bus connector 10/10
6.2.1 Overview of the set 10/10
Figure 30 Overview of the set 10/10
6.2.2 Mounting
Solder the plug-in connectors A1, A2, and B1 onto your
PCB.
Solder the two metal terminals onto your PCB.
Insert the PCB.
Put the top and bottom parts together.
Solder the plug-in connector B2 to the PCB of the hous-
ing base ME PLC 40 B BUS 10/10 GY7035, 2201500.
6.2.3 Coding
You have the option to codify the bus connector and the
housing. This should prevent a housing being accidentally
plugged onto the wrong bus connector.
Figure 31 Coding option
Coding sets in rectangular and drop form are available (see
“Ordering data” on page 3).
Plug one part of the coding set into the opening of the
bus connector.
The counter-part goes into the housing.
Bus connector kit consisting of 2 x 10-pos. plug-in connec-
tors, plastic upper part and base, plus metal clamp for mount-
ing the DIN rail, PCB not included
ME PLC 40 BUS 10/10 KIT BK 2201503
A1 A2
B2
B1
Observe the proper orientation of the PCB when
inserting it into the housing. The housing base
has raised supports on one side. The PCB side
with the cut-out belongs on this side.
ME PLC 40...
105504_en_01 PHOENIX CONTACT 22
6.2.4 Dimensional drawing PCB 10/10
Figure 32 Dimensional drawing of the PCB for the bus connector set 10/10
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
25,85
25,85
6,26
19,6 2,4
86
41,9
1,3
25,5
37,8
6,5
5,6
1,5
Ø1,35
10
2,5
2,5
2,55
1,5
2,2
ME PLC 40...
105504_en_01 PHOENIX CONTACT 23
6.2.5 10-pos. base strip (A1) for 10/10
Figure 33 Dimensions MC 1.5/10-G-3.81
Figure 34 Drilling diagram MC 1.5/10-G-3.81
MC 1.5/10-G-3.81,1803358
The precise location of the plug-in connectors on
the PCB can be found in Figure 32 on page 22.
a
a+5,2
2,6 3,81
18,7
9,2
8
11,1
7,25
3,4
a = 34.29 mm
8
a
1,2
3,81
2,6
a = 34.29 mm
Dimensions / Positions
Length 9.2 mm
Pitch 3.81 mm
Dimension a 34.29 mm
No. of positions 10
Pin dimensions 0.8 x 0.8 mm
Hole diameter 1.2 mm
Technical data
Range of articles MC 1.5/..-G
Insulation material group IIIa
Rated surge voltage (III/3) 2.5 kV
Rated surge voltage (III/2) 2.5 kV
Rated surge voltage (II/2) 2.5 kV
Rated voltage (III/2) 160 V
Rated voltage (II/2) 250 V
Connection in acc. with standard EN-VDE
Nominal current IN 8 A
Nominal voltage UN 160 V
Maximum load current 8 A
Insulation material PBT
Inflammability class in acc. with UL 94 V0
Color green
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 8 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 8 A
ME PLC 40...
105504_en_01 PHOENIX CONTACT 24
6.2.6 10-pos. base strip (A2) for 10/10
Figure 35 Dimensions IMC 1.5/10-G-3.81
Figure 36 Drilling diagram IMC 1.5/10-G-3.81
IMC 1.5/10-G-3.81, 1862658
The precise location of the plug-in connectors on
the PCB can be found in Figure 32 on page 22.
a+4,6
a
2,3
3,81
25,7
6,85
7,83,4
14,5
2,54 1,86
a = 34.29 mm
1,2
a
2,54 1,86
2,3 3,81
a = 34.29 mm
Dimensions / Positions
Length 14.5 mm
Pitch 3.81 mm
Dimension a 34.29 mm
No. of positions 10
Pin dimensions 0.8 x 0.8 mm
Hole diameter 1.2 mm
Technical data
Range of articles IMC 1.5/..-G
Insulation material group I
Rated surge voltage (III/3) 2.5 kV
Rated surge voltage (III/2) 2.5 kV
Rated surge voltage (II/2) 2.5 kV
Rated voltage (III/2) 160 V
Rated voltage (II/2) 320 V
Connection in acc. with standard EN-VDE
Nominal current IN 8 A
Nominal voltage UN 160 V
Maximum load current 8 A
Insulation material PA
Inflammability class in acc. with UL 94 V0
Color green
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 8 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 8 A
ME PLC 40...
105504_en_01 PHOENIX CONTACT 25
6.2.7 10-pos. base strip (B1) for 10/10
Figure 37 Dimensions MCV 1.5/10-G-3.81
Figure 38 Drilling diagram MCV 1.5/10-G-3.81
MCV 1.5/10-G-3.81, 1803507
The precise location of the plug-in connectors on
the PCB can be found in Figure 32 on page 22.
3,4 18,7
11,1
7,25
3
9,2
a
a+5,2
2,6 3,81
a = 34.29 mm
a
1,2
3
3,81
2,6
a = 34.29 mm
Dimensions / Positions
Length 7.25 mm
Pitch 3.81 mm
Dimension a 34.29 mm
No. of positions 10
Pin dimensions 0.8 x 0.8 mm
Hole diameter 1.2 mm
Technical data
Range of articles MCV 1.5/..-G
Insulation material group IIIa
Rated surge voltage (III/3) 2.5 kV
Rated surge voltage (III/2) 2.5 kV
Rated surge voltage (II/2) 2.5 kV
Rated voltage (III/2) 160 V
Rated voltage (II/2) 250 V
Connection in acc. with standard EN-VDE
Nominal current IN 8 A
Nominal voltage UN 160 V
Maximum load current 8 A
Insulation material PBT
Inflammability class in acc. with UL 94 V0
Color green
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 8 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 8 A
ME PLC 40...
105504_en_01 PHOENIX CONTACT 26
6.2.8 10-pos. base strip (B2) for contacting in the bus connector set 10/10
Figure 39 Dimensions IMC 1.5/10-G-3.81
Figure 40 Drilling diagram IMC 1.5/10-G-3.81
6.2.9 IMC 1.5/10-G-3.81, 1862658
Figure 41 Dimensional drawing of the PCB of the housing (2201499) with plug-in connector (B2)
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
a+4,6
a
2,3
3,81
25,7
6,85
7,83,4
14,5
2,54 1,86
a = 34.29 mm
1,2
a
2,54 1,86
2,3 3,81
a = 34.29 mm
Dimensions / Positions
Length 14.5 mm
Pitch 3.81 mm
Dimension a 34.29 mm
No. of positions 10
Pin dimensions 0.8 x 0.8 mm
Hole diameter 1.2 mm
Technical data
Range of articles IMC 1.5/..-G
Insulation material group I
Rated surge voltage (III/3) 2.5 kV
Rated surge voltage (III/2) 2.5 kV
Rated surge voltage (II/2) 2.5 kV
Rated voltage (III/2) 160 V
Rated voltage (II/2) 320 V
Connection in acc. with standard EN-VDE
Nominal current IN 8 A
Nominal voltage UN 160 V
Maximum load current 8 A
Insulation material PA
Inflammability class in acc. with UL 94 V0
Color green
Nominal voltage, UL/CUL Use Group B 300 V
Nominal current, UL/CUL Use Group B 8 A
Nominal voltage, UL/CUL Use Group D 300 V
Nominal current, UL/CUL Use Group D 8 A
R1,2
166,8
47,731,7
37,36
5,3 39,66
2
3,45
4,2
3,4
R1,2
8
38,89
39,66
ME PLC 40...
105504_en_01 PHOENIX CONTACT 27
7 Array and fitted plate
7.1 Dimensional drawing array
Figure 42 Dimensional drawing array (2201496)
The array and the fitted plate can be mounted under the
transparent cover.
The array has a defined hole raster in which for example
LEDs of the 7-segment display can be positioned.
The fitted plate can be used universally.
7.2 Dimensional drawing fitted plate
Figure 43 Dimensional drawing fitted plate (2201497)
Matrix with defined engagement mechanism, for assembly
underneath the cover in short design (ME PLC 40 CS...),
color: black
ME PLC 40 MT S BK 2201496
Fitted plate, for assembly underneath the cover in short de-
sign (ME PLC 40 CS...), color: light gray
ME PLC 40 PL S GY7035 2201497
35,2
29,4
7,5
2,96,7
3,2
7x3,2 (=22,4)
2,3
11,4
15,2
19
47,3
9,5
8,9
12,5
We can gladly make openings for any of your dis-
play or operating elements.
35,2
47,3
ME PLC 40...
105504_en_01 PHOENIX CONTACT 28
7.3 Dimensional drawing of the PCB for mounting
under array or fitted plate
Figure 44 Dimensional drawing of the horizontal PCB for
mounting under the array (2201496) or the fit-
ted plate (2201497)
7.4 Dimensional drawing housing PCB (housing
with array or with fitted plate)
Figure 45 Dimensional drawing of the perpendicular
housing PCB when using the array (2201496)
or the fitted plate (2201497)
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
Ø1,3
29,2 3
5,7 18,65
44,8
13,3
7
0,9
30,5
35,2
1,2
1,2
1,2
1,2
7,05
90,6
79,65 6,6
36,9
3,7
118,5
R1,2
R1,2
R1,2
ME PLC 40...
105504_en_01 PHOENIX CONTACT 29
8 Close with cover (without array or fitted plate)
8.1 Dimensional drawing housing PCB
Figure 46 Dimensional drawing of the housing PCB
when using the short cover without array or fit-
ted plate
Both cover versions serve to close the display area of the
housing.
Display elements can be protected against touch and dust
under the transparent cover.
The light-gray cover closes off the housing when no display
elements are being used.
Cover, short design, color: light gray ME PLC 40 CS GY7035 2201490
Cover, short design, color: transparent ME PLC 40 CS TRANS 2201491
The detailed PCB contour and the locked areas
can be found in the 3D housing data.
The 3D-CAD download can be found at
phoenixcontact.net/products.
90,6
79,65 6,6
36,9
3,7
131,7
R1,2
R1,2
R1,2
ME PLC 40...
105504_en_01 30
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
© PHOENIX CONTACT 2014-01-24 – 52004299 _01 – DB EN HQ ME PLC 40
9 Mounting on a DIN rail
9.1 Mounting on NS 105/20
Figure 47 Dimensional drawing with NS 105/20
9.1.1 Order key for DIN rail NS 105/20
Order, for example, a 40-mm long DIN rail with "1 / 2201508
/ 40".
9.1.2 Dimensions of the DIN rail NS 105/20
Figure 48 Dimensions NS 105/20
9.2 Mounting on NS 35/15
Figure 49 Dimensional drawing with NS 35/15
As an alternative, the housing can be snapped onto two NS
35/15 DIN rails.
No bus connectors can be mounted in this fastening mode.
Quantity Order no. Length [mm]
1 2201508 40
min. 40 mm
max. 2000 mm
105
20
105
93
20
105
35 35
15
15