BICRON
BICRON Electronics Company
50 Barlow Street Canaan, CT 06018
Tel: 860 824-5125 Fax: 860 824-1137
email: info@bcrn.com
www.bcrn.com
“Excellence Through Teamwork”
EX9PA050
Current Sensor
0 to 5 Amperes
Applications:
䡲Current measurements and control
䡲Power demand measurements
䡲Current signature of motors
䡲Load sensing
䡲Ground fault sensing
䡲Monitoring of process parameters
䡲Status of lamps, heaters
䡲Power failure
䡲Loss of device
Features:
䡲Low cost AC current sensing
䡲Designed for easy electronic interface
䡲Electrically isolated output
䡲No external power requirements
䡲Printed circuit board mounting
䡲Extremely reliable
Fax toll-free to our Engineering
Hotline (1-800-355-5125) for assistance
in selecting the current transformer best
suited for your application.
BICRON’s “Modified Standard”
program lets us modify our standard electri-
cal and mechanical design specifications
without incurring significant engineering or
manufacturing setup charges. This is just one
of the many ways we can help optimize your
current transformer system at low cost and
with little delay.
Specifications:
䡲Turns Ratio . . . . . . . 200:1
䡲DCR . . . . . . . . . . . . . . 1.6Ω
䡲Error . . . . . . . . . . . . . 5% max.
䡲Frequency . . . . . . . . 47–400Hz
䡲Current Range . . . . . 0 –5Arms
䡲Overload Current . . 20Arms
䡲Ambient . . . . . . . . . . -35°C to +80°C
䡲Programmable
Burden (load)
Resistor (Rs) . . . . . . . User Supplied
䡲Performance
per Equation . . . . . . Vs=(I
p)(Rs)/200