S/MOD/SKD10306/A/29/11/1999 page 1 / 2 F/GB RELAIS STATIQUE DC POUR CIRCUIT IMPRIME DC SOLID STATE RELAY FOR PRINTED CIRCUIT BOARD SKD10306 3-30 VDC input 3 A / 60 VDC output * Gamme pour circuit imprime. * Sortie DC . * Range for printed circuit board * DC Output. Aplication typique/Typical application + 43,2 0, 4 10,2 0,35 1+ +3 0,35 25,4 4 -3 + 2- 6,5 7,63 0,2 12,7 5,08 0, 2 2- 1+ 1+ 10,16 0, 5 O1 2- -4 (*) (*) Sur charges inductives./ On inductive loads 7,62 0, 2 Charge / Load TOLERANCES: 0,3 - Caracteristiques d'entree (a 20C) / Input characteristics (20C) Parametre / Parameter Plage de tension de commande (Uc) / Input voltage range (Uc) Tension maximum de commande / Maximum control voltage Tension minimum de commande / Minimum control voltage Courant de fonctionnement/Operating current Courant maximum de commande / Maximum control current Tension de relachement/Release voltage Resistance interne / Input internal resistor Symbol Uc Uc max Uc min Ic Ic max Uc off Rc 3-30 30 3 1 30 1 1000 Unit VDC VDC VDC mADC mADC VDC - 40 a/to +105 -40 a/to +80 2500 8 20 Unit C C VRMS pF g Caracteristiques generales / General characteristics Parametre / Parameter Temperature de stockage / Storage temperature Temperature de fonctionnement /Operating temperature Tension d'isolement entree-sortie / Input-output isolation voltage Capacite entree-sortie/ Input-output capacity Poids/Weight Proud to serve you All technical characteristics are subject to change without previous Caracteristiques sujettes a modifications sans preavis. notice. celduc r e l a i s S/MOD/SKD10306/A/29/11/1999 page 2 / 2 F/GB Caracteristiques de sortie (a 20) / Output characteristics(20C) Parametre / Parameter Tension nominale / Nominal voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Courant nominal (voir les caracteristiques thermiques) / Nominal current (see thermal curves) Courant de surcharge accidentel admissible maximum / Maximum accidental overload current Chute tension directe (In) / On state voltage drop (IN) Courant de fuite etat bloque / Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture / Turn on time Temps d'ouverture / Turn off time Frequence d'utilisation / Operating frequency dv/dt etat bloque / Off state dv/dt Homologation / Approval 2 a/to 60 60 Unit VDC VDC VPEAK 3 A 10 1,6 APEAK VDC 1 5 200 800 0 a/to 500 200 mA mA s s Hz V/s Nous consulter /Consult us Fig.2 Caracteristiques thermiques / thermal curves : 5 Courant commute (A) / Switched current (A) 4 Tension de commande/ Input voltage <10VDC sans/ without LED 3 2 1 Tension de commande/ Input voltage =30VDC ou modeles avec LED/or models with LED 0 0 10 20 30 40 50 60 70 80 90 100 110 Temperature ambiante (C) / Ambient temperature (C) Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. * Dans le cas de plusieurs modules cote a cote, prevoir un derating en courant. * In case of many SSRs side by side, take a derating current in to account. * Sur charges inductives prevoir une diode de roue libre (ou ecreteur de surtension ). * On inductive loads put a free-wheeling diode (or clamp ). celduc r e l a i www.celduc.com s Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19