Ordering information AC-DC Power Supplies Medical Type PMA15F PM 1 A 2 15 3 F Recommended EMI/EMC Filter NAM-04-000 R Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. Horizontal terminal block (option : -T1) Vertical terminal block (option : -T) MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT Standard type PMA15F-3R3 9.9 3.3V 3A 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 T : Vertical terminal block T1 : Horizontal terminal block N : with Cover J1 : VH(J.S.T.)connector type Specification is changed at option, refer to Instruction Manual. with Cover (option : -N) PMA15F-5 15 5V 3A -O 4 PMA15F-12 15.6 12V 1.3A PMA15F-15 15 15V 1A PMA15F-24 16.8 24V 0.7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT PMA SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 ACIN 100V ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] *1 -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] PMA15F-3R3 PMA15F-5 PMA15F-12 PMA15F-15 PMA15F-24 AC85 - 264 1f (Refer to the Instruction Manual 1.1 and 3.2) *3 0.30typ (Io=100%) 0.40typ (Io=100%) 0.15typ (Io=100%) 0.20typ (Io=100%) 50 / 60 (47 - 440) 76typ 76typ 66typ 70typ 74typ 79typ 79typ 67typ 74typ 78typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.05/0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) 3.3 5 12 15 24 3.0 3.0 1.3 1.0 0.7 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 60max 60max 150max 180max 290max 20max 20max 48max 60max 96max 200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. 20typ (ACIN 100V, Io=100%) 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 13.20 to 18.00 19.20 to 27.00 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 20.00 to 25.00 30.00 to 37.00 LED (Green) Not provided AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max *3 -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter *4) 31X78X103mm [1.22X3.07X4.06 inches] (WXHXD) / 230g max (with cover : 265g max) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Derating is required. When two or more units are used, they may not comply with the harmonic attenuator. Please contact us for details. PMA-2 *5 *6 * * * Please contact us about safety approvals for the model with option. Please contact us about another class. Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading. PMA15F Block diagram FUSE AC250V 2.5A AC IN 85 264V INRUSH CURRENT LIMIT NOISE FILTER RECTIFIER AND FILTER FG TRANSFORMER RECTIFIER AND FILTER INVERTER CONTROL DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view External size of option T,T1 and N is different from standard model and refer to 4 Option of instruction manual for detalis. 103 [4.06] 3 1 46 0.5 CN1 40.5 [1.81] [1.59] 2-M3 Mounting Hole Point A:C102 2-M3 Mounting Hole 18 Name plate 75 0.5 Point A,Point B are thermometry points. Please refer to Instruction Manual 3. I/O Connector Mating Connector CN1 1-1123724-3 1-1123722-5 CN2 1-1123723-4 Terminal 1123721-1 Chain Loose 1318912-1 Chain 1123721-1 1-1123722-4 Loose 1318912-1 (Mfr : Tyco Electronics AMP) I/O Connector is Mfr.Tyco Electronics AMP Option : -J1 : (J.S.T) connector type -T : Vertical terminal block type -T1 : Horizontal terminal block type Refer to Instruction Manual 4. [2.95] 34.5 5 [1.36] FG AC(L) AC(N) 78 4 3 2 1 31 +V -V [3.07] CN2 [1.22] 70.5 [2.78] [0.48] Point B:C503 LED Cover name plate Cover (Option) 36.5 Voltage Adjust [1.44] 2.5 [0.1] 12.2 1.5 [0.71] 18 [0.71] 8.5 [0.33] CN1 Pin No. 1 2 3 4 5 CN2 Input AC(N) AC(L) FG Pin No. Output 1, 2 -V 3, 4 +V Tolerance : 1 [0.04] Weight : 230g max (with cover : 265g max) PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Electric galvanizing steel board Keep drawing current per pin bellow 5A of CN2. Dimensions in mm, [ ]=inches Mounting torque : 0.6N-m (6.3kgf-cm) max Please connect safety ground to the unit in 2-M3 holes. PMA-3 PMA Ordering information AC-DC Power Supplies Medical Type PMA30F PM 1 A 2 30 3 F Recommended EMI/EMC Filter NAM-04-000 R Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. Horizontal terminal block (option : -T1) Vertical terminal block (option : -T) MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT Standard type PMA30F-3R3 19.8 3.3V 6A 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 T : Vertical terminal block T1 : Horizontal terminal block N : with Cover J1 : VH(J.S.T.)connector type Specification is changed at option, refer to Instruction Manual. with Cover (option : -N) PMA30F-5 30 5V 6A -O 4 PMA30F-12 30 12V 2.5A PMA30F-15 30 15V 2A PMA30F-24 31.2 24V 1.3A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT PMA SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 ACIN 100V ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] *1 -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] PMA30F-3R3 PMA30F-5 PMA30F-12 PMA30F-15 PMA30F-24 AC85 - 264 1f (Refer to the Instruction Manual 1.1 and 3.2) *3 0.50typ (Io=100%) 0.70typ (Io=100%) 0.30typ (Io=100%) 0.40typ (Io=100%) 50 / 60 (47 - 440) 67typ 71typ 76typ 77typ 77typ 69typ 74typ 78typ 80typ 80typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.05 / 0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) 3.3 5 12 15 24 6.0 6.0 2.5 2.0 1.3 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 60max 60max 150max 180max 290max 20max 20max 48max 60max 96max 200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. 20typ (ACIN 100V, Io=100%) 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 13.20 to 18.00 19.20 to 27.00 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 20.00 to 25.00 30.00 to 37.00 LED (Green) Not provided AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3 -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter *4) 31X82X120mm [1.22X3.23X4.72 inches] (WXHXD) / 240g max (with cover : 280g max) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Derating is required. When two or more units are used, they may not comply with the harmonic attenuator. Please contact us for details. PMA-4 *5 *6 * * * Please contact us about safety approvals for the model with option. Please contact us about another class. Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading. PMA30F Block diagram FUSE AC250V 3.15A AC IN 85 264V INRUSH CURRENT LIMIT NOISE FILTER RECTIFIER AND FILTER FG TRANSFORMER INVERTER CONTROL RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view External size of option T,T1 and N is different from standard model and refer to 4 Option of instruction manual for detalis. 2.5 [0.44] 120 [4.72] Cover name plate 0.5 Point B:C503 LED [0.02] 11.2 1.5 82 Voltage Adjust [3.23] 17 [0.67] [0.1] Cover (Option) CN2 4 3 2 1 FG AC(L) AC(N) 5 1 35 2-M3 Mounting Hole 3 77 0.5 CN1 [1.38] 71 [2.8] +V -V 4 [3.03] [0.16] Point A:C102 Name plate I/O Connector CN1 1-1123724-3 CN2 1-1123723-4 Terminal 1123721-1 Chain 1-1123722-5 Loose 1318912-1 Chain 1123721-1 1-1123722-4 Loose 1318912-1 (Mfr : Tyco Electronics AMP) [3.46] Mating Connector I/O Connector is Mfr.Tyco Electronics AMP Option : -J1 : (J.S.T) connector type -T : Vertical terminal block type -T1 : Horizontal terminal block type Refer to Instruction Manual 4. 34.5 [1.36] 31 [1.22] 18 88 0.5 Point A,Point B are thermometry points. Please refer to Instruction Manual 3. [0.71] 2-M3 Mounting Hole 11 [0.43] CN1 Pin No. 1 2 3 4 5 CN2 Input AC(N) AC(L) FG Pin No. Output 1, 2 -V 3, 4 +V Tolerance : 1 [0.04] Weight : 240g max (with cover : 280g max) PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Keep drawing current per pin bellow 5A of CN2. Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m (5kgf-cm) max Please connect safety ground to the unit in 2-M3 holes. PMA-5 PMA Ordering information AC-DC Power Supplies Medical Type PMA60F PM 1 A 2 60 3 F 4 Recommended EMI/EMC Filter NAM-04-000 R Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. Horizontal terminal block (option : -T1) Vertical terminal block (option : -T) MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT Standard type PMA60F-3R3 39.6 3.3V 12A with Cover (option : -N) PMA60F-5 60 5V 12A -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 T : Vertical terminal block T1 : Horizontal terminal block N : with Cover J1 : VH(J.S.T.)connector type R : with Remote ON/OFF Specification is changed at option, refer to Instruction Manual. PMA60F-12 60 12V 5A PMA60F-15 60 15V 4A PMA60F-24 60 24V 2.5A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT PMA SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 *5 ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] *1 -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE ON/OFF *3 INPUT-OUTPUT.RC INPUT-FG *3 OUTPUT.RC-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] PMA60F-3R3 PMA60F-5 PMA60F-12 PMA60F-15 PMA60F-24 AC85 - 264 1f (Refer to the Instruction Manual 1.1) 0.7typ (Io=100%) 0.8typ (Io=100%) 0.4typ (Io=100%) 0.5typ (Io=100%) 50 / 60 (47 - 63) 77typ 80typ 80typ 81typ 81typ 78typ 83typ 82typ 83typ 83typ 0.98typ 0.85typ 0.90typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.09 / 0.18max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) 3.3 5 12 15 24 12.0 12.0 5.0 4.0 2.5 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 60max 60max 150max 180max 290max 20max 20max 48max 60max 96max 250typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 13.20 to 18.00 19.20 to 27.00 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 20.00 to 25.00 30.00 to 37.00 LED (Green) Optional (Required external power source) AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *4 -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 *6 32X82X135mm [1.26X3.23X5.31 inches] (WXHXD) / 350g max (with cover : 395g max) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Applicable when Remote ON/OFF (optional) is added. RC is insulated with input, output and FG. Derating is required. Please contact us about safety approvals for the model with option. PMA-6 *6 * * * Please contact us about class C. Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading. PMA60F Block diagram FUSE 250V3.15A AC IN 85 NOISE FILTER 264V INRUSH CURRENT LIMIT RECTIFIER FG CURRENT SENSING BOOSTER INDUCTOR OPTION RC E EXTERNAL SOURCE CURRENT SENSING RECTIFIER AND FILTER CONTROL CONTROL OVER VOLTAGE PROTECTION INVERTER INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view External size of option T,T1,R and N is different from standard model and refer to 4 Option of instruction manual for detalis. CN3 Connector for Remote ON/OFF(option) [5.31] Cover name plate Cover (Option) 12 CN2 6 5 4 3 2 1 +V 71 -V [2.8] 0.5 LED [0.02] [0.44] FG AC(L) AC(N) 5 3 1 2-M3 Mounting Hole 35 Voltage Adjust Point A:C118 Point B:C505 135 82 [0.67] [0.1] 11.21.5 [3.23] 2.5 [1.38] 17 CN1 4 0.5 [0.16] Name plate 105.5 0.5 [4.15] Point A,Point B are thermometry points. Please refer to Instruction Manual 3. I/O Connector Mating Connector CN1 1-1123724-3 1-1123722-5 CN2 1-1123723-6 Terminal 1123721-1 Chain Loose 1318912-1 Chain 1123721-1 1-1123722-6 Loose 1318912-1 (Mfr : Tyco Electronics AMP) I/O Connector is Mfr.Tyco Electronics AMP Option : -J1 : (J.S.T) connector type -T : Vertical terminal block type -T1 : Horizontal terminal block type Refer to Instruction Manual 4. CN1 Pin No. 1 2 3 4 5 CN2 Input AC(N) AC(L) FG Pin No. Output 1-3 -V 4-6 +V 9 [0.35] [1.4] 35.5 32 [1.26] 18 2-M3 Mounting Hole [0.71] 94 [3.7] Connector type CN3 Option (Mfr:J.S.T) PIN No. 1 2 Contents RC(+) RC(-) Barrier strip type Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 Tolerance : 1 [0.04] Weight : 350g max (with cover : 395g max) PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Keep drawing current per pin bellow 5A of CN2. Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m (5kgf-cm) max Please connect safety ground to the unit in 2-M3 holes. PMA-7 PMA Ordering information AC-DC Power Supplies Medical Type PMA100F PM 1 A 2 100 3 F 4 Recommended EMI/EMC Filter NAM-06-000 R Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. Horizontal terminal block (option : -T1) Vertical terminal block (option : -T) MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT Standard type PMA100F-3R3 66 3.3V 20A with Cover (option : -N) PMA100F-5 100 5V 20A -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 T : Vertical terminal block T1 : Horizontal terminal block N : with Cover J1 : VH(J.S.T.)connector type R : with Remote ON/OFF Specification is changed at option, refer to Instruction Manual. PMA100F-12 102 12V 8.5A PMA100F-24 108 24V 4.5A PMA100F-48 100.8 48V 2.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT PMA SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 *5 ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] *1 -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE ON/OFF *3 INPUT-OUTPUT.RC INPUT-FG *3 OUTPUT.RC-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] PMA100F-3R3 PMA100F-5 PMA100F-12 PMA100F-24 PMA100F-48 AC85 - 264 1f (Refer to the Instruction Manual 1.1) 0.9typ (Io=100%) 1.3typ (Io=100%) 0.5typ (Io=100%) 0.7typ (Io=100%) 50 / 60 (47 - 63) 77typ 81typ 82typ 84typ 84typ 78typ 83typ 83typ 86typ 86typ 0.98typ 0.85typ 0.90typ 20typ (Io=100%) (At cold start) 40typ (Io=100%) (At cold start) 0.09 / 0.18max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) 3.3 5 12 24 48 20.0 20.0 8.5 4.5 2.1 20max 20max 48max 96max 192max 40max 40max 100max 150max 240max 80max 80max 120max 120max 150max 140max 140max 160max 160max 200max 120max 120max 150max 150max 250max 160max 160max 180max 180max 300max 50max 50max 120max 240max 480max 60max 60max 150max 290max 600max 20max 20max 48max 96max 192max 250typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 19.20 to 27.00 39.00 to 53.00 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 24.00 to 24.96 48.00 to 49.92 Works over 105% of rating and recovers automatically 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 30.00 to 37.00 58.00 to 65.00 LED (Green) Optional (Required external power source) AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *4 -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 *6 34X93X168mm [1.34X3.66X6.61 inches] (WXHXD) / 560g max (with cover : 625g max) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. Applicable when Remote ON/OFF (optional) is added. RC is insulated with input, output and FG. Derating is required. Please contact us about safety approvals for the model with option. PMA-8 *6 * * * Please contact us about class C. Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading. PMA100F Block diagram FUSE 250V3.15A AC IN 85 264V NOISE FILTER RECTIFIER INRUSH CURRENT LIMIT FG CURRENT SENSING BOOSTER INDUCTOR OPTION RC EXTERNAL SOURCE CURRENT SENSING RECTIFIER AND FILTER CONTROL E CONTROL OVER VOLTAGE PROTECTION INVERTER INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view External size of option T,T1,R and N is different from standard model and refer to 4 Option of instruction manual for detalis. 2-M3 Mounting Hole 5 3 [2.3] 19 [5.49] CN2 1-1123723-8 Terminal 1123721-1 Chain 1318912-1 Loose Chain 1123721-1 1-1123722-8 1318912-1 Loose (Mfr : Tyco Electronics AMP) I/O Connector is Mfr.Tyco Electronics AMP Option : -J1 : (J.S.T) connector type -T : Vertical terminal block type -T1 : Horizontal terminal block type Refer to Instruction Manual 4. [0.35] CN1 Pin No. 1 2 3 4 5 CN2 Input AC(N) AC(L) FG 9 Pin No. Output 1-4 -V 5-8 +V CN3 Option (Mfr:J.S.T) [1.48] 37.5 [1.34] 81 [3.19] 139.5 0.5 Point A,Point B are thermometry points. Please refer to Instruction Manual 3. Connector type 2-M3 Mounting Hole Name plate 1-1123722-5 0.5 58.5 78 0.5 Mating Connector [0.02] 1 CN1 [3.07] I/O Connector 93 8 7 6 5 4 3 2 1 -V CN1 1-1123724-3 [3.66] 12 CN2 +V FG AC(L) AC(N) Point A:C118 [6.61] 37.5 LED Cover name plate Cover (Option) [1.48] [0.46] 34 11.71.5 Voltage Adjust CN3 Connector for Remote ON/OFF(option) Point B:C505 168 2.5 [0.1] [0.75] 17.5 [0.69] PIN No. 1 2 Contents RC(+) RC(-) Barrier strip type Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 Tolerance : 1 [0.04] Weight : 560g max (with cover : 625g max) PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Keep drawing current per pin bellow 5A of CN2. Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m (5kgf-cm) max Please connect safety ground to the unit in 2-M3 holes. PMA-9 PMA