saia-burgess Switches Ph: 800-429-0365 www.saia-burgess-usa.com Fax: 847-549-9625
B4
B
Snap-action Microswitches – Subminiature XC
Operating Characteristics
Actuating Release Free Operating Movement Total travelled
Actuator Reference Force Force Position Position Differential position
Maximum Minimum Maximum Maximum Maximum
(N) (oz) (N) (oz) (mm) (in) (mm) (in) (mm) (in) (mm) (in)
Plunger
XCF.. 3 10.70 0.5 1.78 8.8 0.34 8.4 0.33 0.1 0.003 7.7 0.30
(mm)
XCG.. 1.7 6.07 0.3 1.07 8.8 0.34 8.4 0.33 7.7 0.30
XCK.. 1.2 4.28 0.2 0.71 8.8 0.34 8.4 0.33 0.1 0.003 7.7 0.30
XCC.. 0.6 2.14 0.1 3.57 8.8 0.34 8.4 0.33 0.1 0.003 7.7 0.30
XCH.. 0.35 1.24 0.07 0.24 8.8 0.34 8.4 0.33 0.1 0.003 7.7 0.30
-J1 Lever
XCF.. 1.05 3.74 0.16 0.57 12.2 0.48 10.2 ± 1.0 0.401 ± 0.039 0.6 0.023 8.4 0.33
(mm)
XCG.. 0.6 2.14 0.08 0.28 12.2 0.48 10.2 ± 0.9 0.401 ± 0.035 0.5 0.019 8.5 0.34
XCK.. 0.42 1.49 0.056 0.19 12.2 0.48 10.3 ± 0.9 0.405 ± 0.035 0.5 0.019 8.7 0.34
XCC.. 0.22 0.78 0.025 0.08 12.2 0.48 10.3 ± 0.9 0.404 ± 0.035 0.4 0.015 8.7 0.34
XCH.. 0.13 0.46 0.02 0.07 12.2 0.48 10.4 ± 0.9 0.409 ± 0.035 0.4 0.015 8.8 0.35
Width of lever 4.0 mm/0.16 in
-L1 Lever
XCF.. 1.1 3.92 0.17 0.6 17.6 0.69 15.6 ± 1.1 0.614 ± 0.043 0.6 0.023 14 0.56
(mm)
XCG.. 0.7 2.49 0.09 0.32 17.6 0.69 15.6 ± 1.0 0.614 ± 0.039 0.5 0.019 14.1 0.56
XCK.. 0.43 1.53 0.058 0.2 17.6 0.69 15.7 ± 1.0 0.618 ± 0.039 0.4 0.015 14.3 0.56
XCC.. 0.23 0.82 0.026 0.09 17.6 0.69 15.7 ± 1.0 0.618 ± 0.039 0.4 0.015 14.3 0.56
XCH.. 0.14 0.49 0.021 0.07 17.6 0.69 15.8 ± 1.0 0.622 ± 0.039 0.4 0.015 14.4 0.57
Width of lever 4.0 mm/0.16 in
-S1 Lever
XCF.. 1.1 3.92 0.17 0.6 17.6 0.69 15.6 ± 1.2 0.614 ± 0.047 0.6 0.023 14.1 0.56
(mm)
XCG.. 0.7 2.49 0.09 0.32 17.6 0.69 15.6 ± 1.1 0.614 ± 0.043 0.5 0.019 14.2 0.56
XCK.. 0.43 1.53 0.058 0.2 17.6 0.69 15.7 ± 1.1 0.618 ± 0.043 0.4 0.015 14.4 0.57
XCC.. 0.23 0.82 0.026 0.09 17.6 0.69 15.7 ± 1.1 0.618 ± 0.043 0.4 0.015 14.4 0.57
XCH.. 0.14 0.49 0.021 0.07 17.6 0.69 15.8 ± 1.1 0.622 ± 0.043 0.4 0.015 14.5 0.57
Width of roller 4.0 mm/0.16 in. for high temperature use -T1 lever
-P5 Lever
XCF.. 1.3 4.62 0.17 0.6 17.6 0.69 15.6 ± 1.1 0.614 ± 0.043 0.6 0.023 14 0.55
(mm)
XCG.. 0.75 2.67 0.09 0.32 17.6 0.69 15.6 ± 1.0 0.614 ± 0.039 0.5 0.019 14.1 0.56
XCK.. 0.6 2.13 0.058 0.2 17.6 0.69 15.7 ± 1.0 0.618 ± 0.039 0.4 0.015 14.3 0.56
XCC.. 0.31 1.10 0.026 0.09 17.6 0.69 15.7 ± 1.1 0.618 ± 0.043 0.4 0.015 14.3 0.56
XCH.. 0.22 0.78 0.021 0.07 17.6 0.69 15.8 ± 1.0 0.622 ± 0.039 0.4 0.015 14.4 0.57
-P6 Lever
XCF.. 1.05 3.74 0.16 0.57 14.3 0.56 12.5 ± 1.1 0.49 ± 0.043 0.6 0.023 10.6 0.42
(mm)
XCG.. 0.6 2.13 0.08 0.28 14.3 0.56 12.5 ± 1.0 0.49 ± 0.039 0.5 0.019 10.7 0.42
XCK.. 0.42 1.49 0.056 0.21 14.3 0.56 12.6 ± 1.0 0.5 ± 0.039 0.5 0.015 10.8 0.43
XCC.. 0.22 0.78 0.025 0.11 14.3 0.56 12.6 ± 1.0 0.5 ± 0.039 0.4 0.015 10.8 0.43
XCH.. 0.13 0.46 0.02 0.07 14.3 0.56 12.7 ± 1.0 0.5 ± 0.039 0.4 0.015 10.9 0.43
Ls
Lo
7.5
2.4
6.1
18.0
12.7
Lo
Ls
16
5.9
60º
6.1
12.7
Ls
Lo
Ø 4.8
6.1
12.7
Ls
Lo
16.8
+0.003
–0.011
+0.1
–0.3